CEET 15 GENERAL:
The three-phase electric energy meter of CEET15-xxxx type for active electric energy measuring, according to IEC 1036, respectively, for reactive electric energy measuring , according to IEC 1268, is meant for industrial consumers and commercial agents that use multirate systems for electric energy billing.

TECHNICAL CHARACTERISTICS:
Rated values: Rated voltage Un: Basic current Ib: Rated current In: Max. current Imax: Starting current: Rated frequency: 3x100V, 3x58/100V, 3x400V, 3x230/400V 5A 5A (connection through transformers) 75A, 6A (connection through transformers) 20 mA, 10 mA (connection through transformers) 50 ,60 Hz

Accuracy characteristics and influences: Class: Time base accuracy: 1(2) according to IEC1036 2(3) according to IEC1268 max.0.5s/24h

Climatic characteristics: Temperature range: Temperature range limits: Transport and storage temperature:

-25...+55C -25...+60C -25...+70C

Mechanical and constructive characteristics: Overall dimensions: 254 x 178 x 70 mm Fastening dimensions in three points: 154 x 171 mm Display: LCD dot matrix, 2 lines X 16 alphanumerical characters 8 mm high Optical port: Auxiliary outputs of relay contacts: Operating voltage: Breaking current: Protection degree: Metering and programming possibilities: according to IEC 1107. 240V 2A IP 51.

Metering of imported (Wi) and exported (We) active electric energy; Metering of reactive electric energy in 4 quadrants Q1...Q4; Registering of max. demand in max. 2 registers for each rate; the two max. demand that have been registered can be programmed from : +P, -P, +P+I-PI, Q1, Q2, Q3, Q4, Q1+2, Q3+4, Q1+3, Q2+4. there is also a cummulative max. demand register corresponding to the programmed max. demand register; Number of rates : 4 (of active energy); The reactive energy is metered in one rate which is applied all the time or in one of rates metering the active energy; The registering of the daily balance indexes at a programmed hour and their storage until the next balance registering; Number of rating programmes: 6 ;each programme can be called-in maximum twice a year; Max. Number of the rate switching rules within a programme: 14; Rates changing : as time function, or/and as power function; Automatic changing rule for summer/winter time; The month day when the meter is selfread; The time interval for max. Demand registering.

Other characteristics:

The storage of both the calibrating coefficients and the metered and measured quantities in an EEPROM memory (the storage time without supply voltage : 100 years); Lithium battery for the clock-calendar circuit (battery life time : 5 years from 10 years since battery mounting); Meter monthly selfreading and data memorizing for the last 12 selfreadings; Other quantities memorized in EEPROM : meter series, meter type, subscriber identifier, programme identifier, date of the last programming, date of battery mounting, number of the optical ports accesses.

SYMBOLS
CEET 15 x x x x Interface option 1 - optical interface meter according to IEC 1107; Meter class: 1 - for class meter: 1(2 for reactive energy) 2 - for class meter: 2(3 for reactive energy) Current option:1-5(6) A (meter for current reducers) 2-5(75) A (direct connection meter) Measuring and voltage systems option: 1-2 measuring systems (for 3 wire networks without null), 3 x 100 V; 2-3 measuring systems (for 4 wire networks with null), 3 x 58/100 V; 3-2 measuring systems (for 3 wire networks without null), 3 x 400 V; 4-3 measuring systems (for 4 wire networks with null), 3 x 230/400 V.

Connection diagram
CEET15-42(3)xx
R1
15 16

CEET15-21xx
COM.

R2
17 18 19 20

R1
15 16

R2
17 18 19 20

COM.
21 22

21

22

1 1 2 3 N

10 11

1
A

9 10 11

A B

a b

A B

a b S1 P1 S2 P2 S1 P1 S2 P2 S1 P1 S2 P2

b B

1 2 3 N

CEET15-32(3)xx
R1 R2
COM.
19 20 21 22 15 16 17 18

CEET15-11xx
R1 R2
COM.
19 20 21 22 15 16 17 18

1 1 2 3

9 10 11

9 10 11

a B A

b B S1 P1 S2 P2 S1 S2

1 2 3

AEM,1900 Timisoara, Calea Buziasului, No26, ROMANIA Tel: +40 56 222200; Fax: +40 56 190928; E-mail: sales@aem.ro;

Internet:http://www.aem.ro