Progressive Odour 
Management Plan
Victoria Zavras. 
The  presence  of  nuisance  odours  originating  from  any 
facility ‐ identified during operator, manager or regulator 
site  inspection,  or  a  neighbour  complaint  verified  by  a 
“trained”  nose  –  initiates  the  first  four  levels  of  action 
Anotec Pty Limited that  take  place  successively  until  the  odour  conditions 
external  to  the  property  are  acceptable  to  the  local 
30‐32 Chegwyn Street
health  department  or  regional  air  quality  authority.  
Botany NSW 2019
Anotec  recommends  that  Levels  one  through  to  four 
Tel: 02 9700 1222 | Fax: 02 9700 1771 form  part  of  your  operating  requirements  or  EMP 
(Environmental Management Plan). 
Email: service@anotec.com.au
 
•Self‐ Odour  •Review of 
Audit & Site  Operating 
Inspection procedures

Level  Level 
1 2

Level  Level 
4 3
•Consider  •Review of Raw 
retrofitting or  Materials and 
upgrade of plant existing pollution 
control devices
 

Level 1  Level 2 

Level  1  is  a  self  odour  inspection  and  Level  2  is  to  change  the  operating  procedures.    This  is 
correction  operation.    Each  of  the  implemented  if  the  odours  are  still  persisting  and  you  have 
operational  aspects  of  the  business  done  the  best  you  can  with  the  tools  available  in  Level  1 
that  impact  on  odour  generation  and  operations,  the  company  and  regulators  evaluate  those 
control  is  evaluated  by  operating  improper  conditions  together,  as  a  team,  and  outline  new 
personnel  to  determine  their  procedures and handling methods. 
contribution to the offensive odour.    Changes  that  reduce  odours  are  adopted  into  the  plan  of 
operation  and  maintained.    Level  1  can  now  continue  to  be 
implemented. 

Level 3  Level 4 

This  level  involves  restriction  of  either  raw  materials  Level 4 is basically retrofitting.  When designed 


or  existing  chemical  pollution  control  devices.    If  the  and fully implemented, the effectiveness of the 
odours are still a problem, those chemicals should be  corrections will be evaluated.  Once the changes 
suspended  from  acceptance  in  large  volumes  until  are in place, normal operations can resume and 
changes  in  operations  or  handling  prove  to  create  the business will operate at the Level 1 mode for 
acceptable  odour  conditions.    If  at  this  time  the  odour assessment and control. 
facilities  is  still  generating  the  unreasonable  odours,   
or if Management wishes to substantially change the   
facility to resolve the odour problems for the omitted   
raw materials, then Level 4 needs to be entered into.   
Odour  Identification  &  Response  prior  to  level  4  is   
important  because  the  fourth  level  of  remediation   
most  likely  will  impact  ongoing  operations   
significantly.    Good  planning  and  establishment  of  Anotec Pty Ltd | PO Box 292 | Botany NSW 1455 
benchmarks need to occur before going to that level.   Tel: 02 9700 1222 | Fax: 02 9700 1771 |  
At this level, Odour Complaints should be approached  Email: service@anotec.net 
more formally. 