You are on page 1of 8

Electric Motors

Table of Contents

J1

Electric Motors

INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J2
THREE PHASE TEFC GENERAL PURPOSE MOTORS . . . . . . . . . J3
SINGLE PHASE TEFC GENERAL PURPOSE MOTORS . . . . . . . . J4
TOTALLY ENCLOSED BRAKEMOTORS . . . . . . . . . . . . . . . . . . . . . J4
WASHDOWN DUTY MOTORS . . . . . . . . . . . . . . . . . . . . . . . . . . . J5 & J7
INVERTER DUTY MOTORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J6
PERMANENT MAGNET DC MOTORS . . . . . . . . . . . . . . . . . . . . . . . J7
MOTOR DIMENSIONS TABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J8

E-mail: sales@footejones.com

Web: www.footejones.com

Electric Motors

J2

Electric Motors

Performance matched to Foote-Jones gear drives.

BASIC SPECIFICATIONS
Power Ratings from 1/4 to 30 hp

1.15 Service Factor


Operating Speed 1750 rpm
Single Phase or Three Phase Design

STANDARD FEATURES
Motors Produced by Regal Beloit for High Efficiency,
Reliability and Durability
UL Recognized and CSA Certified
Ball Bearings for Endurance and Strength
Totally Enclosed General Purpose Motors Feature
Steel Frames
Brake Motors Feature Stearns Brakes, Bolt-On
Removable Bases
Washdown Motors Feature USDA Approved White
Epoxy Paint, 303 Stainless Steel Shafts, Internal
Corrosion Resistant Coatings and
Class F Insulation System
Inverter Duty Motors Feature Encoder and Brake
Provisions,
Class F Insulation System, and Three Year Warranty
DC Motors Feature Oversized Brushes for Long Life,
Class F Insulation System, and Two Year Warranty.

OPTIONAL FEATURES
Adjustable Speed Motor Controls Available
Modified Standard and Custom Designs
CleanLine Washdown and BISSC Configurations
Unique or Harsh Environment Adaptations
Motor/Gear Drive Package Incentives Available,
Consult Factory

Phone: (605) 225-0360

Fax: (605) 225-0567

Electric Motors

Three Phase TEFC General Purpose

J3

THREE PHASE TEFC 1750 RPM C-FACE MOTORS

Ball bearings, mechanically locked on shaft end


1.15 Service factor
Rolled steel 56-145T frame motors
UL Recognized and CSA Certified
HP

Volts

Frame

Cat. No.

Nom.
Eff.

F.L.
AMPS

Weight
LBS

LQ
Dim.

Footnote

1/4
1/3
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
20
25
30

208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460

56C
56C
56C
56C
56C
56C
56C
182TC
184TC
213TC
215TC
254TC
256TC
284TC
286TC

G547
G502
G507
G522
G527
G541
G544
C223
C224
C225
C226
C227
(1) U724
(1) U725
(1) U726

66.0
68.0
68.0
75.5
77.0
80.0
82.5
82.5
86.5
87.5
88.5
88.5
91.0
92.4
92.4

1.2-1.3/.65
1.5-1.6/0.8
2.1-2.2/1.1
2.7-2.8/1.4
3.5-3.6/1.8
4.8-4.8/2.4
6.0-5.8/2.9
8.0/4.0
13.0/6.5
22.0-19.4/9.7
27.6-25.0/12.5
41.0-38.6/19.3
51.0/25.5
68.0-63.0/31.5
81.0-74.0/37.0

14
15
17
21
27
29
39
76
92
103
135
179
225
425
455

7.88
8.13
8.63
9.13
10.26
10.26
11.75
13.07
14.07
16.09
17.59
19.24
20.99
21.68
23.18

20, 24
20, 24
20, 24
20, 24
20
20
20
F
F, 20
F, 20
F, 20
AL, F
AL, F, 20
F, 20
F, 20

Notes:

(1) FRAME IS C FACE WITH RIGID BASE

575 VOLT THREE PHASE TEFC 1750 RPM C-FACE MOTORS

Ball bearings, mechanically locked on shaft end


1.15 Service factor
Rolled steel 56-145T frame motors
UL Recognized and CSA Certified

HP

Volts

Frame

Cat. No.

Nom.
Eff.

F.L.
AMPS

Weight
LBS

LQ
Dim.

1/3
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10

575
575
575
575
575
575
575
575
575
575

56C
56C
56C
56C
56C
145TC
182TC
184TC
213TC
215TC

(1) G503
(1) G508
(1) G523
(1) G528
(1) G548
(1) G549
(2) C383
(2) C387
(2) C391
(2) C394

68.0
68.0
75.5
77.0
80.0
82.5
87.5
88.5
89.5
89.5

0.64
0.90
1.10
1.45
1.90
2.25
3.40
5.20
8.00
10.40

15
18
20
26
28
41
77
87
122
135

8.13
8.63
9.13
10.26
10.26
11.57
13.07
14.03
16.35
17.85

Notes: (1) C FACE - FOOTLESS

Footnote
24
24
24

F
F
F
F

(2) C FACE WITH REMOVABLE BASE

Footnotes:
AL
F

20
24

Aluminum Frame Construction


Class F Insulation

Rated 60/50 hertz, 190/380 or 380 volt at next lower horsepower


Motor will not accept brake kit

APPLICATION GUIDELINES
Guidelines for Application General Purpose,
Three Phase Motors on Variable Frequency Drives
Meets NEMA MG-1-1998 Part 30 and Part 31 Section 4.4.2

Enclosure

Efficiency

Frame

10:1
Variable
Torque
2:1 C.T.

Totally Enclosed

Standard

56-326

Maximum Inverter to motor


cable length @ 3KHz carrier
230 V
460 V
575 V
600 ft

125 ft

40 ft

Contact Marathon Electric for guidelines in applying explosion proof motors on inverters.
Carrier frequency is measured phase-to-phase, not phase-to-bus. Higher carrier frequencies require shorter cable
Contact HUB CITY for details.

E-mail: sales@footejones.com

Specifications are subject to change without notice.

Web: www.footejones.com

Electric Motors

J4

Single Phase TEFC General Purpose & Totally Enclosed Brakemotors

SINGLE PHASE TEFC 1750 RPM C-FACE MOTORS

Ball bearings, mechanically locked on shaft end


Heavy gauge steel frame
Capacitor start design for high starting torque
1.15 Service factor
UL Recognized and CSA Certified
HP

Volts

Frame

Cat. No.

F.L. AMPS

Weight
LBS.

LQ Dim.

Footnotes

1/4
1/3
1/2
3/4
1
1-1/2

115/208-230
115/208-230
115/208-230
115/208-230
115/208-230
115/208-230

56C
56C
56C
56C
56C
56C

G511
G513
G515
G517
G519
G531

4.2/2.1-2.1
6.0/3.0-3.0
8.0/4.0-4.0
11.0/5.4-5.5
13.4/6.8-6.7
15.2/8.2-7.6

16
18
23
30
31
40

7.88
8.38
9.13
10.26
10.76
11.76

N,2,17,24
2, 24
2, 24
2
2
1

Footnotes:
N
1
2

Totally Enclosed, Non-Ventilated


Capacitor Start/Capacitor Run design for reduced amperage
Capacitor Start Induction Run design

17
24

1.0 Service Factor


Motor will NOT accept a Brake Kit

SINGLE PHASE TEFC 1750 RPM C-FACE BRAKEMOTORS


Fail-safe, spring set Stearns brake for
holding or stopping
Brake has manual wear adjustment up to
10lb.-ft. for longer pad life
Manual release lever on rear of brake
housing
Brake leads are terminated at the brake
Vertical or horizontal mounting

Brake coil voltage matches motor


voltages
Bolt-on, easily removable rigid base
Ball bearings, mechanically locked on
shaft end
1.15 Service factor
Nameplated 60/50 hertz at next
lowest horsepower
UL Recognized and CSA Certified

HP

Volts

Frame

Cat. No.

Brake
Rating

F.L.AMPS

Weight
LBS.

LQ Dim.

Footnotes

1/3
1/2
3/4
1
1-1/2

115/208-230
115/208-230
115/208-230
115/208-230
115/208-230

56C
56C
56C
56C
56C

D400
D401
D402
D403
D404

3
3
6
6
10

6.6/3.1-3.3
8.8/4.2-4.4
11.0/5.4-5.5
13.4/6.8-6.7
15.2/8.2-7.6

33
35
38
40
53

14.14
14.14
14.64
15.14
16.14

1
1
1
1
2

Footnotes:
1
2

Capacitor Start/Capacitor Run design for reduced amperage


Capacitor Start Induction Run design

THREE PHASE TEFC 1750 RPM C-FACE BRAKEMOTORS

In addition to the Single Phase Features above:


Brake leads routed through motor conduit box (TENV only)
Suitable for vertical mounting, 10 lb.-ft. and smaller
CR200 Corona resistant magnet wire (motor
can be operated 10:1 variable torque and 2:1 constant torque)
1.15 Service factor, 1.0 Service factor where footnoted

Phone: (605) 225-0360

HP

Volts

Frame

Cat. No.

Brake
Rating

F.L.AMPS

Weight
LBS.

LQ Dim.

1/3
1/2
3/4
1
1-1/2
2

208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460

56C
56C
56C
56C
56C
145TC

D450
D452
D454
D456
D457
C403

3
3
6
6
10
10

1.8-1.6/0.8
2.3-2.4/1.2
2.9-3.0/1.5
3.5-3.6/1.8
4.8-4.8/2.4
6.0-5.8/2.9

31
32
33
35
41
48

13.67
14.17
14.17
15.17
15.20
16.65

Fax: (605) 225-0567

Electric Motors

Washdown Duty

J5

SINGLE PHASE TOTALLY ENCLOSED 1750 RPM C-FACE WASHDOWN DUTY MOTORS

Double sealed ball bearings


303 Stainless steel shaft with spring loaded contact seals in each endshield
Electronic encapsulated starting switch is impervious to moisture
Cast conduit box with threaded openings, stainless steel cover
Internal corrosion resistant coatings on frame, base, endshields, rotor
and stator
USDA-approved, white epoxy paint
Plugged drain holes in each endshield for all angle mounting
Capacitor start design for high starting torque
Class F insulation
1.15 Service factor
Capacity start/induction run design

HP

Volts

Frame

Cat. No.

F.L. AMPS

Weight
LBS.

LQ Dim.

1/3
1/2
3/4
1
1-1/2

115/208-230
115/208-230
115/208-230
115/208-230
115/208-230

56C
56C
56C
56C
56C

N531
N523
N525
N527
N529

6.4/3.2-3.2
8.8/4.4-4.4
10.8/5.4-5.4
12.8/6.4-6.4
19.0/9.5-9.5

27
29
31
37
43

8.63
9.13
9.63
10.13
11.63

THREE PHASE TOTALLY ENCLOSED 1750 RPM C-FACE WASHDOWN DUTY MOTORS
Variable torque (6-60Hz) 1.0 Service Factor on VFD
See Inverter Duty column for constant torque capability
Double sealed ball bearings
303 Stainless steel shaft with spring loaded contact seals in each
endshield
Cast conduit box with threaded openings, stainless steel cover
Internal corrosion resistant coatings on frame, base, endshields,
rotor and stator
USDA-approved, white epoxy paint
Plugged drain holes in each endshield for all angle mounting
Stainless steel fan guard
MAX GUARD Class F insulation system
1.15 Service factor
Suitable for use on VFD, see Inverter Duty column below.
HP

Volts

Frame

Cat. No.

1/4
1/3
1/2
3/4
1
1-1/2
2

208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460

56C
56C
56C
56C
56C
56C
56C

N564
N565
N567
N599
N602
N606
N611

Inverter
Duty
6:1
6:1
6:1
6:1
6:1
6:1
3:1

CT
CT
CT
CT
CT
CT
CT

Nom.
Eff.

F.L. AMPS

Weight
LBS.

LQ Dim.

Footnotes

67.0
68.0
78.5
80.0
80.0
80.0
81.5

1.1-1.1/.6
1.7-1.7/.9
1.8-1.8/.9
2.5-2.5/1.3
3.6-3.6/1.8
5.0-5.0/2.5
6.2-6.2/3.1

21
23
27
30
31
36
38

8.63
8.63
8.00
8.50
9.50
11.00
10.63

N
N
N
N
N
N

Footnotes:
N
Totally Enclosed, Non-Ventilated

E-mail: sales@footejones.com

Web: www.footejones.com

Electric Motors

J6

Three Phase Inverter Duty

THREE PHASE TOTALLY ENCLOSED NON-VENTILATED 1750 RPM


C-FACE INVERTER DUTY MOTORS
MAX GUARD Class F insulation system
Constant torque operation from 0 to base speed on Vector Drive
Constant horsepower to twice base RPM
Continuous duty at 40 C ambient
Optimized for operation with IGBT inverter (NEMA Design A)
Normally closed thermostats (one per phase)
Removable Base on some models, as noted
Ball bearing
Field reversible to F2 (except where noted)
Encoder and brake provisions included on opposite drive end (maximum 10 lb-ft brake
UL Recognized and CSA Certified (contact factory for CE marking)
Three year warranty
Rigid mounting base

HP

Volts

Range

Frame

Cat. No.

F.L.AMPS

Weight
LBS.

LQ Dim.

Footnotes

1/4
1/2
1
2
3
5
7-1/2
10

230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460

1000:1
1000:1
1000:1
1000:1
1000:1
1000:1
1000:1
1000:1

56C
56C
143TC
145TC
182TC
184TC
213TC
215TC

Y592
Y534
Y536
Y551
Y541
Y543
Y545
Y547

1.2
1.6/0.8
3.0/1.5
6.0/3.0
8.4/4.2
13.0/6.5
21.4/10.7
27.0/13.5

17
28
43
70
96
98
146
159

9.70
11.42
12.92
12.56
15.32
16.32
17.12
19.62

S, 13
S, 6, 13
S, 6, 13

Footnotes:
AL
Aluminum Frame Construction
S
Steel Frame Construction

6
13

AL
AL
AL
AL

Bolt-on, removable base for footless mounting option


F1 Mounting Only, Cannot reassemble to F2

THREE PHASE 575 VOLT TOTALLY ENCLOSED NON-VENTILATED


1750 RPM C-FACE INVERTER DUTY MOTORS
MAX GUARD Class F insulation system
Constant torque operation from 0 to base speed on Vector Drive
Constant horsepower to twice base RPM
Continuous duty at 40 C ambient
Optimized for operation with IGBT inverter (NEMA Design A)
Normally closed thermostats (one per phase)
Removable base on some models, as noted
Ball bearing
Field reversible to F2 (except where noted)
Encoder and brake provisions included on opposite drive end (maximum 10 lb-ft brake
UL Recognized and CSA Certified (contact factory for CE marking)
Three year warranty
Rigid mounting base

HP

Volts

Range

Frame

Cat. No.

F.L.AMPS

Weight
LBS.

LQ Dim.

Footnotes

1/2
1
2
3
5
7-1/2
10

575
575
575
575
575
575
575

1000:1
1000:1
1000:1
1000:1
1000:1
1000:1
1000:1

56C
56C
145TC
182TC
184TC
213TC
215TC

Y555
Y556
Y557
Y558
Y559
Y560
Y561

0.6
1.2
2.4
3.4
5.4
7.0
10.8

28
41
70
96
98
146
159

11.42
12.92
12.56
15.32
16.32
17.12
19.62

S, 6, 13
S, 6, 13

Footnotes:
AL
Aluminum Frame Construction
S
Steel Frame Construction

Phone: (605) 225-0360

6
13

AL
AL
AL
AL

Bolt-on, removable base for footless mounting option


F1 Mounting Only, Cannot reassemble to F2

Fax: (605) 225-0567

Electric Motors

Permanent Magnet DC Motors

J7

SCR RATED, TOTALLY ENCLOSED,1750 RPM C-FACE WITH REMOVABLE BASE

Class F insulation
NEMA C-Face with removable rigid base
Oversized brushes for extra long life
Permanently lubricated sealed ball bearings
Linear speed/torque characteristics over entire speed range
High starting torque, high peak current capability
Usable on PWM type DC adjustable speed drives at higher HP rating
Easy brush access with unique brush holder design
UL Recognized and CSA Certified
2 year warranty

HP

DC
Volts

Frame

Encl.

Cat. No.

C.T. Speed.
Range

F.L. AMPS

*PWM HP
Rating

Weight
LBS.

LQ Dim.

Footnotes

1/4
1/4
1/3
1/3
1/2
1/2
3/4
3/4
1
1
1-1/2
2
3

90
180
90
180
90
180
90
180
90
180
180
180
180

56C
56C
56C
56C
56C
56C
56C
56C
56C
56C
56C
145TC
182/145TC

TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC

Z602
Z603
Z604
Z605
Z606
Z607
Z610
Z611
Z612
Z613
Z614
Z616
Z619

2:1
2:1
2:1
2:1
2:1
2:1
2:1
2:1
2:1
2:1
2:1
2:1
2:1

2.5
1.4
3.5
1.7
5.0
2.5
7.6
3.8
10.0
5.0
7.6
9.5
14.0

0.40
0.50
0.50
0.50
0.70
0.56
1.00
1.00
1.25
1.25
1.75
2.00
3.00

19
22
23
22
24
25
27
27
40
40
51
78
89

10.81
11.31
11.31
11.31
11.81
11.81
13.81
13.81
15.81
14.81
16.81
20.15
21.87

84,85

Footnotes: 84

NEMA 145TC face mounting with removable 182T rigid base

85

Not tach adaptable

WASHDOWN, SCR RATED, TOTALLY ENCLOSED,1750 RPM


C-FACE WITH REMOVABLE BASE
Class F insulation
NEMA C-Face with removable rigid base
Oversized brushes for extra long life
Doubled sealed, oversized ball bearings
Corrosion resistant 303 stainless steel shaft
High temperature, moisture resistant
lubricant
Exterior and interior components protected
with enamel & polyester compounds

Aluminum conduit box, threaded and


gasketed
"V" ring Forsheda seals
Drains at 3:00, 6:00, 9:00 and 12:00
locations
Sealed machine fits
Stainless steel nameplate
USDA approved white epoxy paint
UL Recognized and CSA Certified
2 year warranty

HP

DC
Volts

Frame

Encl.

Cat. No.

C.T. Speed.
Range

F.L. AMPS

*PWM HP
Rating

Weight
LBS.

LQ Dim.

1/4
1/3
1/2
1/2
3/4
3/4
1
1
1-1/2

90
90
90
180
90
180
90
180
180

56C
56C
56C
56C
56C
56C
56C
56C
56C

TENV
TENV
TENV
TENV
TENV
TENV
TEFC
TEFC
TEFC

Z630
Z631
Z634
Z635
Z636
Z637
Z638
Z639
Z641

20:1
20:1
20:1
20:1
20:1
20:1
2:1
2:1
2:1

2.7
3.5
4.9
2.4
7.0
3.5
10.0
5.0
7.6

0.30
0.56
0.75
0.70
1.25
1.25
1.25
1.25
1.75

23
26
38
39
50
50
42
42
50

8.63
9.63
11.63
11.63
13.63
13.63
13.75
12.75
14.75

*SCR PMDC motors on PWM power supplies

Pulse width modulated DC controls have a voltage output similar to pure direct current which has a form factor of 1.05. SCR thyristor drives
have a form factor of 1.40. Marathon Electric's non-Explosion Proof PMDC, SCR-rated motors can also be used with PWM controls, and due
to the lower form factor and the resultant lower heating in the motor, their rating can be increased as indicated above. Operation on PWM
controls will also result in quieter operation and longer brush life.

E-mail: sales@footejones.com

Web: www.footejones.com

Electric Motors

Electric Motors

J8

TYPICAL RIGID BASE MOTOR

TYPICAL C-FACE MOTOR

C
(48-184)
(182T-449)
BB

45

45

AK BD

'H' DIA
4 HOLES

+.00
D -.06

+.00
D -.06

AA
LEAD HOLE

AA
LEAD HOLE

BA

AB

N-W

AB

BS
2F
B

P
AH
AH

AJ
E

BS

BA
'H' DIA.
4 HOLES

2F
(B)

E
A
BF
4 HOLES

E
A

Frame

2F

O
(MAX)

P
(MAX)

N-W

AA

AB
(MAX)

AH

AJ

AK

BA

BB
(MIN)

BD
(MAX)

BF

48
56
56H
143T
145T
182
184
182T
184T
213
215
213T
215T
254U
256U
254T
256T
284U
286U
284T
286T
284TS
286TS
324U
326U
324T
326T
324TS
326TS
364U
365U
364T
365T
364TS
365TS

3.00
3.50
3.50
3.50
3.50
4.50
4.50
4.50
4.50
5.25
5.25
5.25
5.25
6.25
6.25
6.25
6.25
7.00
7.00
7.00
7.00
7.00
7.00
8.00
8.00
8.00
8.00
8.00
8.00
9.00
9.00
9.00
9.00
9.00
9.00

2.12
2.44
2.44
2.75
2.75
3.75
3.75
3.75
3.75
4.25
4.25
4.25
4.25
5.00
5.00
5.00
5.00
5.50
5.50
5.50
5.50
5.50
5.50
6.25
6.25
6.25
6.25
6.25
6.25
7.00
7.00
7.00
7.00
7.00
7.00

2.75
3.00
5.00
4.00
5.00
4.50
5.50
4.50
5.50
5.50
7.00
5.50
7.00
8.25
10.00
8.25
10.00
9.50
11.00
9.50
11.00
9.50
11.00
10.50
12.00
10.50
12.00
10.50
12.00
11.25
12.25
11.25
12.25
11.25
12.25

.34 SLOT
.34 SLOT
.34 SLOT
.34
.34
.41
.41
.41
.41
.41
.41
.41
.41
.53
.53
.53
.53
.53
.53
.53
.53
.53
.53
.66
.66
.66
.66
.66
.66
.66
.66
.66
.66
.66
.66

5.83
6.32
6.74
7.45
7.45
9.38
9.38
9.38
9.38
11.00
11.00
11.00
11.00
14.09
14.09
14.09
14.09
14.94
14.94
14.94
14.94
14.94
14.94
15.93
15.93
15.93
15.93
15.93
15.93
19.00
19.00
19.00
19.00
19.00
19.00

5.66
5.66
6.48
7.75
7.75
9.76
9.76
9.76
9.76
11.50
11.50
11.50
11.50
14.27
14.27
14.27
14.27
15.88
15.88
15.88
15.88
15.88
15.88
15.88
15.88
15.88
15.88
15.88
15.88
20.00
20.00
20.00
20.00
20.00
20.00

.5000
.6250
.6250
.8750
.8750
.8750
.8750
1.1250
1.1250
1.1250
1.1250
1.3750
1.3750
1.3750
1.3750
1.625
1.625
1.625
1.625
1.875
1.875
1.625
1.625
1.875
1.875
2.125
2.125
1.875
1.875
2.125
2.125
2.375
2.375
1.875
1.875

1.50
1.88
1.88
2.25
2.25
2.25
2.25
2.75
2.75
3.00
3.00
3.38
3.38
3.75
3.75
4.00
4.00
4.88
4.88
4.62
4.62
3.25
3.25
5.62
5.62
5.25
5.25
3.75
3.75
6.38
6.38
5.88
5.88
3.75
3.75

1/2
1/2
1/2
3/4
3/4
3/4
3/4
3/4
3/4
1
1
1
1
1-1/4
1-1/4
1-1/4
1-1/4
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
2
2
2
2
2
2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2

7.04
7.04
8.08
8.08
8.08
8.08
9.31
9.31
9.31
9.31
10.96
10.96
10.96
10.96
13.19
13.19
13.19
13.19
13.19
13.19
13.69
13.69
13.69
13.69
13.69
13.69
17.88
17.88
17.88
17.88
17.88
17.88

1.69
2.06
2.06
2.12
2.12
2.12
2.12
2.62
2.62
2.75
2.75
3.12
3.12
3.50
3.50
3.75
3.75
4.62
4.62
4.38
4.38
3.00
3.00
5.38
5.38
5.00
5.00
3.50
3.50
6.12
6.12
5.62
5.62
3.50
3.50

3.750
5.875
5.875
5.875
5.875
5.875
5.875
7.250
7.250
7.250
7.250
7.250
7.250
7.250
7.250
7.250
7.250
9.000
9.000
9.000
9.000
9.000
9.000
11.000
11.000
11.000
11.000
11.000
11.000
11.000
11.000
11.000
11.000
11.000
11.000

3.000
4.500
4.500
4.500
4.500
4.500
4.500
8.500
8.500
8.500
8.500
8.500
8.500
8.500
8.500
8.500
8.500
10.500
10.500
10.500
10.500
10.500
10.500
12.500
12.500
12.500
12.500
12.500
12.500
12.500
12.500
12.500
12.500
12.500
12.500

2.50
2.75
2.75
2.25
2.25
2.75
2.75
2.75
2.75
3.50
3.50
3.50
3.50
4.25
4.25
4.25
4.25
4.75
4.75
4.75
4.75
4.75
4.75
5.25
5.25
5.25
5.25
5.25
5.25
5.88
5.88
5.88
5.88
5.88
5.88

.16
.16
.16
.16
.16
.16
.16
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25

5.62
6.50
6.50
6.50
6.50
6.50
6.50
9.00
9.00
9.00
9.00
9.00
9.00
10.00
10.00
10.00
10.00
11.25
11.25
11.25
11.25
11.25
11.25
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00

1/4-20
3/8-16
3/8-16
3/8-16
3/8-16
3/8-16
3/8-16
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11

*C dimensions can be calculated by adding the LQ dimensions on gear motor pages J3 to J7 to the AH dimension.