You are on page 1of 6

42 Meter Tower - 210 Km/h confidence

Shear capacity
Anchor Bolt grade Deformed Bar Minimum Tensile Strength, Shear strength of bolts, Fy = Ub = Ps = = Add a partial safety factor of 1.05 for material and cyclic load due to wind. Ps = =
345 Mpa 372.6 N/mm2 0.4*Ub 149.04 N/mm2

0.4*Ub/1.05 141.94 28 mm Area*1.0 615.75 mm2 Ae*Ps 87.4 kN

Anchor Bolt Diameter Effective area,

Ae = = Cs = Cs =

therefore, Shear capacity

Tension Capacity
Tensile Strength of bolts, Ps = 0.7*Ub 260.8 Add a partial safety factor of 1.05 for material and cyclic load due to wind, Ct Pt = 0.7Ub/1.05 248.4 Bolt diameter 28 Effective Area,Ae Area*0.8 492.60 Therefore , Tensile capacity Ct = Ae*pt Ct = 122.4
N/mm2 N/mm2 mm mm2 kN

Deform bar:
No of bar used (n, b) Diameter of the anchor bolt Cross sectional area Tension capacity , Shear cpacity, Length of anchor bolts Concrete grade Maximum tension force, From Computer Pt-u Ultimate Maximum compressive force From computer Pc-u Ultimate Maximum shear force, From computer Pt Pc Fs 8 28 mm

615.75 mm2
Ct Cs 122.36 kN 87.40 kN 650 mm 17.5 N/mm2 733 kN 879.60 kN 771 kN
925.20 kN 57 kN

Pc-u Ultimate Ultimate Design tension force Ultimate Design compressive force Ultimate Design shear force

Ft Fc Fs

68.40 879.60 925.20 68.40

kN kN kN kN

Checking for Tensile Stress


Total Tension capacity Checking for combined stress Fc/ [n.b * Ct] + Fs / [n.b * Cs]
Ok 1.00 1.33

= No of bolts * Ct
OK

979 kN

Anchorage Length of Bolts


For deform bar type 2 Design ultimate bond stress Fbu (for tension ) = 0.5 * SQRT [Concrete grade] Fbu (for compression) Embedded length [Against tension] = 0.63 * SQRT (Concrete grade) = Ft/ 3.142 * 20 *8 * 2.236

2.09 N/mm2

2.64 N/mm2 598 mm

Embedded length [Against compression] Embedded length < Given Length of anchor bolts OK

499 mm 598 mm

Base Plate design


Max Compressive Force, Column size Depth of section, Dc Width of section, Bc Thickness of flange, Tc Assume: Width of base plate Depth of Base plate Thickness of base plate Concrete grade
500 mm 500 mm 20 mm 17.5 N/mm2

Fc

925.20 kN 160 160 mm 160 mm 10 mm 10

Bearing capacity of concrete Area of plate required, Apreq minimum width required , Plate pressure, Thickness of the plate a b a2 0.3*b2 Design strength of plate Py t2 t Provided thickness

= 0.6 * Con Grade

10.5 N/mm2 88114 mm2 83188.3

L = SQRT(Area)
OK

297 mm 3.70 N/mm2 OK 100 mm 80 mm 10000 mm2 1920 mm2 275 N/mm2 271.84 mm2 16.49 mm Ok

W = Fc/Area

4c2 + 2000 c - 197633


c = 75

544.0

Puy = 255 n/mm2 tp = c [3w/pyp]^0.5


32 w=8.2

879.60

650

500 < 12

20

You might also like