126 Process Simulation using HYSYS

Solution:

Follow the step-by-step instructions to solve the problem. 1- Open a new case.

Tutorial 2
Reactors and Heat Exchangers

2- Add a new component list.


Problem 1 Conversion Reactor Consider a stream of N2 and H2 at 300 F and 500 psia with mole fraction of 0.3 and 0.7, respectively, with a molar flow rate of 100 lbmol/hr. This stream enters a reactor. Conversion of N2 is 30 % and the reactor is isothermal. Calculate the properties of outlet streams using Peng-Robinson equation of state. The following reaction takes place in the reactor: N 2 3H 2 2 NH 3

128 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 127

5- Select the Fluid Package (Make sure selecting Component List -1in the component list).

3- Select the components from the Components list and then close the active window by clicking on cross button (all process components should be entered in this step).

6- Add a new Fluid Package

4- The cross button is not seen on the figure and you could move the active window to see the cross button in order to close it.

130 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 129

9- Go to the Add Rxn button to enter the reaction data.

7- Select the Peng Robinson or SRK equation of state from Property Package.

10- Select the Conversion Reaction and then click on the add Reaction button.

8- Close the Fluid Package by clicking on cross button. After this step, it is possible to import/export the Fluid Package. Go to the Reaction button.

132 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 131

13- Close the active window and return to the following window: The reaction Rxn-1 is added. Add a reaction set by clicking on the Add Set button.

11- Select the components from the drop down menu and then enter the stoichiometry (negative for reactants and positive for products). The balance error should be zero.

14- In the Active List, select Rxn-1 from the drop down menu. Check mark the reaction set and close the active window.

12- Click on the Basis button, select Base Component from drop down menu and enter the conversion for the base component (30 %).

134 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 133

17- The Basis-1 property model is now added to the Fluid Package. Simulation Environment. Then Enter to

15- Click on the Add FP button (This makes the reaction accessible for simulation).

18- Go to Tools/Preference to change the Unit Set to Field.

16- Click on Add Set to Fluid Package Button.

136 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 135

21- Save the simulation work (e.g., problem-1).

19- Go to the Variables button, select Field and close the window (The new unit set may also be cloned by clicking on the Clone button).

22- Enter the mole fractions of the components in Worksheet Composition page. Click OK and close the active window to return to PFD.

20- Drag a material stream to the PFD, click on stream and enter two out of three properties (temperature, pressure and vapor fraction) and molar flowrate in the Worksheet/Conditions Page.

138 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 137

25- Select a conversion reactor from object palette (F4) and drag it to the PFD.

23- The stream properties can now be calculated (seen in the Worksheet/Properties page). Items in blue and black indicate user-defined and calculated properties, respectively.

26- Double click on the reactor and enter Inlet, Vapor and Liquid Outlets and Energy stream in the Design/Connections page. 24- Close the active window and put the curser on the stream to view the Fly-By window.

140 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 139

29- The duty of heat stream is entered in Design/Partameters section. (Make sure to delete the temperature entered in previous section).

27- Go to the Reactions page and select reaction set from the Reaction Set drop down menu.

28- In the Worksheet page, either enter temperature of one of outlet streams or define duty of heat stream. With these information reactor will be solved immediately.

30- The properties of all streams could be viewed in the Worksheet Properties Page.

142 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 141

Solution: Problem 2 CSTR Production of ketene from acetone is performed in a CSTR. CH 3COCH 3 CH 2 CO CH 4 The reaction rate constant (in SI unit) for this reaction is:
k 8.2*1014 exp 2.85 105 where k is in kgmol/m3s. RT

Follow the step-by-step instructions to solve the problem. 1- Open a new case.

Feed stream (pure acetone) enters the reactor at 760 C and 160 kPa with molar flow rate of 140 kmole/hr. The reactor is adiabatic and its volume is 2 m3. Simulate the process using PRSV equation of state.

2- Add a new component list.

144 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 143

5- Select the Fluid Package (Make sure selecting Component List -1in the component list).

3- Select the components from the Components list and then close the active window by clicking on cross button (all process components should be entered in this step).

6- Add a new Fluid Package.

4- The cross button is not seen on the figure and you could move the active window to see the cross button in order to close it.

146 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 145

9- Go to the Add Rxn button to enter the reaction data.

7- Select the PSRV equation of state from Property Package.

10- Select the Kinetic Reaction and then click on the add Reaction button.

8- Close the Fluid Package by clicking on cross button. After this step, it is possible to import/export the Fluid Package. Go to the Reaction button.

148 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 147

13- Go to Parameters page and enter the reaction rate data. 11- Select the components from the drop down menu and then enter stoichiometry of reaction (negative for reactants and positive for products). The balance error should be zero.

14- Go to Close the active window and return to the following window: The reaction Rxn-1 is added. Add a reaction set by clicking on the Add Set button.

12- Click on the Basis button, select Base Component from drop down menu and enter the reaction phase (Overall) and check the units.

150 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 149

17- Click on Add Set to Fluid Package Button.

15- In the Active List, select Rxn-1 from the drop down menu. Check mark the set and close the active window.

18- The Basis-1 property model is now added to the Fluid Package. Simulation Environment. Then Enter to

16- Click on the Add FP button (This makes the reaction accessible for simulation).

152 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 151

21- Enter 1 for acetone mole fraction and zero for the rest in Worksheet/Composition page. Click OK and close the active window to return to PFD. 19- Drag a material stream to the PFD, click on stream and enter temperature, pressure and molar flowrate in the Worksheet/Conditions Page.

22- The stream properties can now be calculated (seen in the Worksheet Conditions page). Items in blue and black indicate user-defined and calculated properties, respectively.

20- Save the simulation work (e.g., problem-2).

154 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 153

25- Double click on the reactor and enter Inlet and outlet streams in Design/Connections.

23- Close the active window and put the curser on the stream to view the Fly-By window.

26- Go to the Reactions page and select set of reaction from Reaction Set drop down menu.

24- Select a CSTR from the object palette (F4) and drag it to the PFD.

156 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 155

29- The properties of all streams could be viewed in the Worksheet/Properties Page.

27- Go to the Rating page and enter the volume (2 m3) for the reactor.

28- In the Reaction/Results page Worksheet page, the actual conversion (%) on the basis of acetone could be seen.

158 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 157

Solution:

Follow the step-by-step instructions to solve the problem. 1- Open a new case.

Problem 3: Equilibrium Reactor Consider a stream of N2 with mole fraction of 0.7 and H2 with a mole fraction of 0.3, which is fed to an equilibrium reactor at 25C and 20 atm with a molar flow rate of 100 kmole/hr to produce ammonia. The operating temperature of reactor is 50 C. Simulate the process, using the library information of HYSYS for equilibrium reactions.

2- Add a new component list.

160 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 159

5- Select the Fluid Package (Make sure selecting Component List -1in the component list).

3- Select the components from the Components list and then close the active window by clicking on cross button (all process components should be entered in this step).

6- Add a new Fluid Package

4- The cross button is not seen on the figure and you could move the active window to see the cross button in order to close it.

162 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 161

9- Go to the Add Rxn button to enter the reaction data.

7- Select the Peng Robinson or SRK equation of state from Property Package.

10- Select the Equilibrium Reaction and then click on the add Reaction.button.

8- Close the Fluid Package by clicking on cross button. After this step, it is possible to import/export the Fluid Package. Go to the Reaction button.

164 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 163

13- In Keq page equilibrium data for the ammonia reaction could be seen.

11- Go to Library page and select ammonia reaction from library and click on Add Library Rxn button.

14- Close the active window. The reaction Rxn-1 is added. Add a reaction set by clicking on the Add Set button.

12- The reaction information will be automatically added to the Stoichiometry page.

166 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 165

17- Click on Add Set to Fluid Package Button.

15- In the Active List, select Rxn-1 from the drop down menu. Check mark the set and close the active window.

18- The Basis-1 property model is now added to the Fluid Package. Simulation Environment. Then Enter to

16- Click on the Add FP button (This makes the reaction accessible for simulation).

168 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 167

21- Enter the mole fractions of the components in Worksheet/Composition page. Click OK and close the active window to return to PFD. 19- Drag a material stream to the PFD, click on stream and enter the temperature, pressure and molar flowrate in the Worksheet/Conditions Page.

22- The stream properties can now be calculated (seen in the Worksheet Properties page). Items in blue and black indicate user-defined and calculated properties, respectively.

20- Save the simulation work (e.g., problem-3).

170 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 169

25- Go to the Reactions page and select a reaction set from the Reaction Set drop down menu.

23- Select an equilibrium reactor from the Object Palette and drag it to the PFD.

26- In the Worksheet page, either enter temperature of one of outlet streams or define duty of heat stream. Enter temperature for the vapor outlet stream.

24- Double click on the reactor and enter inlet, outlet and energy stream in the Design/Connections page.

172 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 171

Problem 4 Heat Exchanger A saturated vapor stream of alkenes (36% n-butane, 34% n-hexane, 30% n-octane in wt. percent) enters to the shell of a heat exchanger at 1000 kPa with mass flow rate of 100 kg/hr. The cooling water at 20 C is used to remove the heat from this stream, where its temperature should not be higher than 50 C in the outlet of the heat exchanger. Calculate the minimum molar flow rate of cooling water so that the temperature of alkenes stream to be 60 C in the outlet of heat exchanger. Choose the Weighted model for the heat exchanger simulation with no pressure drops in both sides.

27- In Reaction Results page, the conversion percent based on nitrogen could be seen.

28- Now, the reactor is simulated.

174 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 173

3- Select the components from the Components list and then close the active window by clicking on cross button (all process components should be entered in this step). Follow the step-by-step instructions to solve the problem. 1- Open a new case.

Solution:

4- The cross button is not seen on the figure and you could move the active window to see the cross button in order to close it.

2- Add a new component list.

176 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 175

7- Select the Peng Robinson or SRK equation of state from Property Package.

5- Select the Fluid Package (Make sure selecting Component List -1in the component list).

8- Close the Fluid Package by clicking on cross button. After this step, it is possible to import/export the Fluid Package. Then enter to Simulation Environment. 6- Add a new Fluid Package.

178 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 177

11- In the Worksheet/Composition page, enter mass fraction of the components, click OK and close the active window to return to PFD.

9- Drag a material stream to the PFD and change its name to Hot-in, then enter its vapor fraction, pressure and molar flowrate in the Worksheet/Conditions Page.

12- Drag another stream to the PFD and change its name to H2O-in, enter its temperature, pressure in the Worksheet/Conditions page.

10- Save the simulation work (e.g., problem-4).

180 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 179

15- Double click on the heat exchanger and enter inlet and outlet streams on the Design/Connections page

13- In the Worksheet Composition page, enter 1 for mole fraction of water and 0 for the rest and click OK and close the active window.

16- In the Design/Parameters page enter 0 for pressure drops of both sides.

14- Select a heat exchanger from the Object Palette (F4) and drag it to the PFD.

182 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 181

19- Enter 60 C for the Hot-out temperature in the Worksheet/Conditions page.

17- In the same page change the heat exchanger model to Weighted and then increase the intervals to 50 to improve accuracy.

20- It is seen in the Design/Specs page that the Degrees of Freedom are reduced to 1.

18- In the Design/Specs page, it is seen that Degrees of Freedom is 2.

184 Process Simulation using HYSYS

Tutorial 2 Reactors & Heat Exchangers 183

23- As seen in the Worksheet/Conditions page, the minimum flow rate of the cooling water is calculated to be 23.16 kmole/hr.

21- In the Worksheet/Conditions page, enter 50 C for H2O-out temperature.

24- So the process is simulated.

22- It can be seen in the Design/Specs page that the Degrees of Freedom are reduced to 0.