You are on page 1of 2

OUTDOOFI SUBSTATION UNIT WITH LENS TOP c''1258

guTsTAtl!gtt{a
FFA?u e Es

MECHA ICAL

1. All metal parts resist conosion.

Cast slip fitter makes fixture easy to install. 3. Unit can be mounted on bracket or post top. 4. Lateral beam adjustment can be made while fixture
is lighted.

;l iit
ql:

9l

5. Gasket assemblies prevent entry of moisture and

dirt to fixture interior.


6. One-piece refractor and lens top are made of pressed prismatic orounar- glass with built-in sa{ety factors to withstand temperature gradients common to operation of outdoor lighting units. 7. Use of tools not required for relamping. 8. Choice of lamps includes 400 watt mercury vapor,
and 500 or 300 watt incandescent.
No. 04252

(o
nllt
9E

a'i
I 2

PEFFOFMANCE

An outstanding development in outdoor substation lighting units is the Holophane one piece refractor with prismatic lens top. The light directing refractor and the light controlling top lens are made of thermally stable rxrunar,i4 glass.
Refractor and lens assembly are supported by a spun-

1. Maximum candlepower produced from same unit at 105" for lateral coverage of low structures and 180" for high mounted switches, 0' being directlv below unit. 2. Outputs of 69?i for mercury vapor and 63% for jncandr.scenl lamps in 90-180' zone assurc maximum utilization of light on overhead switches and struqtures. 3. Glare is absent because all light output is refracted
upward and along the sight lines of switching station or substation operators. 4. Original output can be restored by cleaning outside of lcns top and refractor at relamping time. High operating output is rnaintained between lamp changes by natural action of rain.

on and sealed 16 gauge Alzak aluminum reflector; which, in turn, attaches to a threaded cast aluminum
collar. The collar engages threads in a cast aluminum fitter rvhich supports a mogul base lamp socket, and slip fits over 1%" diameter pipe to a depth of 21tr". Stainless steel set screws are used (A) to secure the fitter on mounting bracket or post top and (B) to prevent rotation of outer collar on inner fitter after lateral light beam adjustment has been set for angles of 100' to 110'. The top lens, 10%" in diameter, is held in a cast metal collar which has 2 stainless steel spring tension latches opposite one another. These latches are hand operated to clamp the lens top to the refractor assembly on a gasket with a bearing surface of %"; this keeps the interior of the fixture dirt and weather tight. The lens top is removed for lamp replacements. Comparisons, on an equal

unit basis, with former

designs of outdoor substation units show a distinct su-

perio|ity of these lens top llxtures. Calculations for a typical layout, r,r'ith disconnect switches 24 feet and lighting units 12 feet above ground, result in 16.8 footcandles using 12 No. 04252 rvith 400 watt clear mercnry vapor lamps. This is about 50!.1 more average initial illumination, on the underside of the horizontal plane

below the disconnect switches. than heretofore achieved.

PHOTOMETRIC TEST REPORI

25

35 55

t25

20

7t
85

t27

\t5

1t
35

251

I550
2365

e1+

J93 7615 27 25

ro?]

2725 1115

rr5rr?+

rrt
120 125
1:15

r2t
r)9
t925 rrr5

kh

itt

t23 te5

t55
r55

Id ot rlalophane No. ro io.


ot

04252

155

2225

|t5

Lnp

Refr..rot

4 7/3"

above borrom

.f

2255

Lhp Hr l- r- cD rqEdrr 21000 wrh 400 rulb BT l7

voh. m.

A.cessoiy-50

MOUNTING ACCESSOBIES
Bracket No. 0876 is used on vertical members of substation structures lor NEW installations of No. 04252. Additional ground lighting units can also be attached to this bracket. For RELIGHTING jobs where there are old style
1%" threaded brackets (Catalog No- 0871-T), an adapt-

Standards for post top mounting of No. 04252 may be secured from post or pole manufacturers. Shields

er, Catalog No.0218 is used for installations of No. 04252 to rcpl^ce obsolete lighting units.

Metal inner shields Sd-51 are available for use on stations near residential properties. Shields can be ordered with new fixtures, or purchased separately and installed in existing fixtures. In final assemblies, shields
may be rotated in fixtures to the most efiective positions.

r tusr. e.P !f5

NU

CATALOG DATA
Cat. No,
SU

Lamp Types and Watts


400W Clear Mercury

Dimensions in Inches
Diam.

Depth

Span

Termination

Net Weight Lbs. Each

o4252

BSTATION UNIT

300-500 lncand.

1,6Ve

2O5/s

19% min. max.

0876 (Bracket) 0218 (Adapter)


Sd-51 (Metal Shield)

)
Converts old style 0871-T to 0876 Bracket.

| for 1'/." pipe 2O1h


1Y2 pipe

I f

.,'o,n

zo

^'E
Yz
1/z

to 1Y, slip 180"-1172" deep

thread

lit

llp.lnp"h"pneir#i,lJff

,Hidih#bru#,r,fi

;*,kJl"::::"
Pr nle.l in

ll

7292 10 27: