Quick Comparison Between the DECS-200 and DECS-200N

Description Continuous Output Ratings 10 Second Forcing Capability Power Stage

Sep-05

Power input

Control Power

Programmable Output Contacts Field Flash

PRODUCT DIFFERENCES DECS-200 DECS-200N Benefit 32, 63 and 125Vdc up to 63 and 125Vdc up to 20Adc Higher output capability to support wider 15Adc range of generators. 30Adc 40Adc Higher forcing capability to support applications that require high initial response. IGBT Accept 1 or 3 phase 6 SCR Bridge, 1 or 3 phase Capable of being powered from a variety power 50 to 500Hz power depending on of different sources. excitation requirements at 50 to 160Hz or 161 to 420Hz option. 60, 120 and 240Vac 1 or 3 120Vac 3 phase or 240Vac 1 Capable of being powered from a variety phase for 32, 63 and 125Vdc phase for 63Vdc of different sources. applications respectively. applications. 240Vac 3 phase for 125Vdc applications. 24/48Vdc or 125Vdc/120Vac 24/48Vdc/24Vac or Allows DECS-200N to be powered by 125/120Vac two different Control Power Sources. Note: Isolation transformer required when dual sources are used. 3 Programmable Output 5 Programmable Output Increases flexibility Contacts Contacts. Relay 4 and 5 Make Rating 30A for 0.2sec N/A Dropout Level and Maximum DECS-200N controls when to apply and Flashing Time remove flashing. Also provides overflash protection. Disable Voltage Matching The selection to only allow Voltage when either 52JK or 52LM Matching to be disabled via 52JK allows contact input opens (Default) the generator to be parallel to other OR just 52JK (Optional) machines isolated from the grid and still allow Bus Voltage Matching to the utility to occur. Built in. The internal crowbar circuit protects against field overvoltage and also is used to discharge energy in the exciter field during shutdown. Screw terminals for Screw Terminals incorporated to Operating Power Input, accommodate higher bridge current and Current Transformer Input able to accept ring-tongue lugs on CT and Bridge output. Tension circuits. clamp terminals for all other connections. 12.0 x 8.75 x 7.94 inches DECS-200N package is slightly larger (304.8 x 222.3 x 201.7 mm) than the DECS-200, while offering a significant space saving advantage over similar negative forcing excitation systems. cURus recognition per UL Combined Agency Recognition Standard 508 and CSA Standard C22.2 No. 14 and CE compliant Not needed. Simplifies Dual DECS-200N Applications

Selection to Disable Voltage Matching via breaker Contact Input

Disables Voltage Matching when either 52JK or 52LM contact input opens

Crowbar Protection

N/A

Terminal Connections

Compression Type

Dimensions H x W x D

12.0 x 8.08 x 7.32 inches (304.8 x 205.2 x 185.9 mm)

Agency

UL, CSA, CE and DNV

Accessory

External Fly back Diode Assembly for Redundant DECS-200s For more information, contact Basler Electric at 618-654-2341or visit http://www.basler.com or email us at info@basler.com

You might also like