Malana-II Design of counterfort retaining wall: Top level of retaining wall Bottom level of counterfort Surcharge angle Angle

of repose Unit weight of concrete Unit weight of Backfill material Bearing capacity of soil Co-efficient of internal friction Partial factor of safety Grade of concrete Yield stress of steel Cover provided Dimensioning of retaining wall: Height of stem Thickness of stem Spacing of counterforts Thickness of counterfort Toe width Base width Heel width Base slab thickness Height of retaining wall Active earth pressure co-efficient Height of backfill at the end of base slab Height of backfill at the end of base slab+base slab Active Earth Pressure Horziontal Component Vertical component Weight of earth fill SBC FOS fck fy C h L b1 B b2 H Ka EL EL 590 578 14 deg 30 deg 25 kN/m 150 kN/m 0.58 1.5 20 N/mm2 2 415 N/mm 0.04 m 12 0.50 4.00 0.40 2.00 7.50 5.00 0.85 12.85 0.367 13.247 14.097 802.53 m m m m m m m m m m m kN (Act at 1/3 of H) (Act at end of Heel) EL 578.00
A
3

EL 590.00 0.50

W4` W5` W1

22 kN/m3
2

12
W3

2
W2
C D

5.00 0.85
B

7.5 Toe Heel

(Assume)

0.54545455 0.8593887 3.0 (Surcharge angle) 0.21043771 0.78956229

4 6

We Wh Wv W3

778.69 kN 194.15 kN 1388.57 kN

Stability Analysis: Assume of 1m strip of retaining wall for stability analysis: S.No 1 2 3 4 5 Load W1 W2 W3 W4 W5 Description Weight of stem Weight of base slab Weight of earth Fill Earth pressure Earth Pressure Total Vertical load Total Horizontal load Unit kN kN kN kN kN Total W P Magnitude Vertical Horizontal 150.00 159.38 1388.57 778.69 194.15 1892.09 kN 1892.09 kN 778.69 kN Distance from point A 2.25 3.75 5.00 4.70 7.50 Resisting moment 337.50 597.66 6942.83 1456.13 9334.11 Overturning moment

3658.99 3658.99

13.247

Factors of safety: Against oveturning: FOS Against sliding: FOS Eccentricity calculation: 403.77 322.97 302.78 m > < 150 150 100.79 7.50
B

2.55 1.40 z e

Safe Unsafe, Shear Key Required 3.00 0.751

403.77 kN/m2 Pmin At Heel 100.79 kN/m2 Upward Pressure not exceding the Bearing capacity of soil Design of stem: Pmax Pressure Intensity Factored Pressure Factored Moment Thickness required Effective depth provided Area of steel required Dia of bar Spacing required Distribution reinf: Dia of bar Spacing required Check for Shear: Shear Force at the base Shear stress devoloped Area of steel provided Percentage of steel provided Allowable shear stress Check for development length: M/V+L Ld M/V+LLd Point of contraflexure: 1213 940 mm mm P Pu Mu dreqd deff Ast

Pressure Distribution At Toe

f
103.82 kN/m 2 155.73 kN/m 207.64 kNm 0.274 m 0.46 m 1330 mm2/m 20 mm 150.00 mm 2 552 mm /m 12 mm 200.00 mm
2

Horizonatal reinf

Vertical reinf

275.64 kN 2 0.55127 N/mm 2 mm /m 2094.40 0.42 %


2 0.44600 N/mm Unsafe

L=12*dia or depth whichever is greater IS456:2000

Safe in Development Length

For fixed support with udl the point of contraflexure occurs at 0.211*L, so the main reinforcement has to be extended upto pt of contraflexure from both the supports. At mid, 3/4 th of reinforcement shall be provided. Point of contraflexure: 1.00 m Since it may be difficult for detailing of reinforcement the same reinforcement shall be provided at both the tension and compression face Also main reinforcement shall be reduced at the top

Design of Toe Slab: Maximum Bending moment acting on the toe slab is calculated by considering moments of all forces about the point c S.No 1 3 Load Wup1 W6 Description Upward Pressure (ACEF) Weight of Toe slab Unit kN kN Total Maximum working moment Factored moment Thickness required Effective Thickness Provided Area of steel required Dia of bar Spacing required Distribution reinf: Dia of bar Spacing required Area of steel provided Magnitude Vertical Horizontal 726.74 -42.50 684.24 711.17 1066.76 0.62 0.81 4073 25 100.00 972 16 200.00 Distance from point C 1.04 1.00 Moment about C 753.67 -42.50 711.17 kNm kNm m m mm2/m mm mm (Parallel to the length of retaining wall)

Ast3

Ast4

mm2/m mm mm 2 4908.739 mm /m

(Parallel to counterfort)

Percentage of steel provided Check for Shear: (Toe Slab) Critical section for shear is at d distance from face of the stem. Shear Force Shear Stress Allowable shear stress

0.606 % i.e 407.12 kN 0.503 N/mm


2

1.19 m from A

0.516 N/mm2 Safe

Design of Heel Slab: Maximum Bending moment acting on the toe slab is calculated by considering moments of all forces about the point b Weight of soil on strip Self weight of heel slab Total doward force Upward pressure Net Downward Pressure Maximum negative moment Factored Moment Depth Provided Area of steel requried Minimum reinforcement required Dia of bar Spacing required Percentage of reinforcement provided Distribution reinforcement: Area of steel required Dia of bar Spacing required Check for Shear: Shear force developed Shear stress developed Allowable shear stress Design of counterforts: Thickness of counterfort Top width of counterfort Bottom width of counterfort Inclination angle of counterfort Depth from face of the stem Effective depth of counterforts Maximum bending moment Factored Bending moment Area of steel required Min reinforcement required Dia of bars No. of bars f n 277.71 kN/m2 21.25 kN/m2 298.96 kN/m2 100.79 kN/m2 kN/m2 kNm kNm m 2 1406.00 mm /m 2 972 mm /m 25 mm 100.00 mm 0.61 % 198.17 264.23 396.35 0.81
2 972 mm /m 16 mm 200.00 mm

0.12% of c/s area

0.12% of c/s area

V v c

396.35 kN 0.47 N/mm2 0.52 N/mm2 Safe

0.40 0.5 5.50 22.62 4.58 5.08 13753.43 20630.14

m m m deg m m kNm kNm 2 12980 mm /m 2 5197.7 mm /m 25 mm 27 nos

Check for Shear: Shear force Percentage of steel provided Allowable shear stress Curtailment of Counterfort bars: Half the bars shall be curtailed at distance of Connection between counterfort and stem: Horizontal force Factored Force Steel required Dia of bar required Spacing required Connection between counterfort and Heel slab: Tension transferred in 1m width of counterfort near the heel Factored force Steel required Dia of bar required Spacing required Design of shear Key: Co-efficient of passive pressure Upward pressure near the key Let depth of shear key Width of the shear key Passive pressure developed Total passive pressure Weight of earthfill in the key Self weight of the key FOS against sliding Cost Estimation: Cost compuatation for counterfort spacing S.No 1 2 3 4 5 6 7 Component Stem Base Slab Counter forts Steel in Stem Toe Slab Heel Slab Counterfort (1 No.) C/s area m2 6.00 6.38 30.00 d' V v Pt c

0 5.50 m 916.97 kN 0.45 N/mm2 0.65 % 0.53 N/mm Safe 3.64 m from top . 339.24 508.86 1409.40 mm2/m 20 mm 200.00 mm 693.61 kN/m2 1040.41 kN 2881.64 mm2/m 20 mm 100.00 mm
2

Kp P a Kp*P Pp *a Wa W

2.72 322.97 0.50 0.50 879.69 kN/m m m


2

kN/m2 439.84 kN 82.5 kN 1892.09 kN 2.03

Thicness/Len gth m 4.00 4.00 0.40

Quantity m3 24.00 25.50 12.00 2.011 0.738 1.845 4.726

Rate

Cost Rs 108000.00 114750.00 54000.00 90509.536 33213.295 83033.236 212665.84 696,172

Rs/m3 4500.00 4500.00 4500.00 45000.00 45000.00 45000.00 45000.00 Total cost

Top level of retaining wall Bottom level of counterfort Surcharge angle Angle of repose Unit weight of concrete Unit weight of Backfill material Bearing capacity of soil Co-efficient of internal friction Dimensioning of retaining wall: Height of stem Thickness of stem Spacing of counterforts Toe width Base width Heel width Base slab thickness Active earth pressure co-efficient

EL EL

1403 1393 0 deg 30 deg 3 25 kN/m


3 18 kN/m 150 kN/m2

0.4

SBC

0.5

H L b1 B b2 Ka

10 0.4 3.5 1.5 6 4.1 0.7 0.33333

m m m m m m m

(Assume)

1.5

4.1

(Surcharge angle)

Stability Analysis: Assume of 1m strip of retaining wall for stability analysis: S.No 1 2 3 4 Load W1 W2 W3 W4 Description Weight of stem Weight of base slab Weight of earth Fill Horizontal earth pressure Unit kN kN kN kN Total W P Magnitude 100.00 105.00 738.00 300.00 1243.00 Distance from Heel 1.70 3.00 3.95 3.33 Resisting moment 170.000 315.000 2915.100 3400.10 Overturning moment

1000.00 1000.00

Total Horizontal load Total Vertical load Factors of safety: Against oveturning: FOS Against sliding: FOS

943.00 kN 300.00

3.40 1.57

Safe Safe

10.00

0.70

Design of counterfort retaining wall: Top level of retaining wall Bottom level of counterfort Surcharge angle Angle of repose Unit weight of concrete Unit weight of Backfill material Bearing capacity of soil Co-efficient of internal friction Partial factor of safety Grade of concrete Yield stress of steel SBC FOS fck fy EL EL 590 582 0 deg 20 deg 25 kN/m
3

EL 590.00 0.50

W4`

18 kN/m3 400 kN/m2 0.50 1.5 25 N/mm2 2 500 N/mm 0.04 m 8 0.50 3.00 0.40 0.75 5.00 3.75 0.50 8.50 0.490 8.000 8.500 318.81 m m m m m m m m m m m kN

W5`

312.2917931

W1

8
W3

EL 582.00
A

0.75
W2
C D

3.75 0.50 5
B

Cover provided C Dimensioning of retaining wall: Height of stem h Thickness of stem Spacing of counterforts L Thickness of counterfort b1 Toe width Base width B b2 Heel width Base slab thickness Height of retaining wall H Ka Active earth pressure co-efficient Height of backfill at the end of base slab Height of backfill at the end of base slab+base slab We Active Earth Pressure Horziontal Component Vertical component Weight of earth fill Wh Wv W3

Toe 6250 (Assume) Safe 5 4.075 4 2.926 0.545 0.859 3.0 0.210 0.790 0.137 0.050 (Act at 1/3 of H) (Act at end of Heel) 3.101 0.016 0.127 1.526 4 6

Heel

Safe (Surcharge angle)

50

318.81 kN 0.00 kN 540.00 kN

Stability Analysis: Assume of 1m strip of retaining wall for stability analysis: S.No 1 2 3 4 5 Load W1 W2 W3 W4 W5 Description Weight of stem Weight of base slab Weight of earth Fill Earth pressure Earth Pressure Total Vertical load Total Horizontal load Unit kN kN kN kN kN Total W P Magnitude Vertical Horizontal 100.00 62.50 540.00 318.81 0.00 702.50 kN 702.50 kN 318.81 kN Distance from Resisting Overturning point A moment moment 1.00 100.00 2.50 156.25 3.13 1687.50 2.83 903.30 5.00 0.00 1943.75 903.30

8.000

Factors of safety: Against oveturning: FOS Against sliding: FOS Eccentricity calculation: 312.29 260.75 226.40 m < < 400 400 0.83 -31.29 5.00
B

2.15 1.10 z e

Safe Unsafe, Shear Key Required 1.48 1.019

Pmax 312.29 kN/m2 Pmin At Heel -31.29 kN/m2 Upward Pressure not exceding the Bearing capacity of soil Design of stem: Pressure Intensity Factored Pressure Factored Moment Thickness required Effective depth provided Area of steel required Dia of bar Spacing required Distribution reinf: Dia of bar Spacing required Check for Shear: Shear Force at the base Shear stress devoloped Area of steel provided Percentage of steel provided Allowable shear stress Check for development length: M/V+L Ld M/V+LLd Point of contraflexure: 987 940 mm mm P Pu Mu dreqd deff Ast

Pressure Distribution At Toe

f
70.60 kN/m2 2 105.90 kN/m 79.43 kNm 0.152 m 0.46 m 404 mm2/m 20 mm 150.00 mm 2 552 mm /m 12 mm 200.00 mm 564.8147672 282.4073836 282.4073836 1035.49374 547.85319

Horizonatal reinf

314.15927 775

1.28597194

Vertical reinf

150.82 kN 2 0.30164 N/mm 2 2094.40 mm /m 0.42 % 2 0.45400 N/mm Safe L=12*dia or depth whichever is greater IS456:2000

256345.5 2.92254E-05 7.4917875

Safe in Development Length

For fixed support with udl the point of contraflexure occurs at 0.211*L, so the main reinforcement has to be extended upto pt of contraflexure from both the supports. At mid, 3/4 th of reinforcement shall be provided. Point of contraflexure: 0.75 m Since it may be difficult for detailing of reinforcement the same reinforcement shall be provided at both the tension and compression face Also main reinforcement shall be reduced at the top

Design of Toe Slab: Maximum Bending moment acting on the toe slab is calculated by considering moments of all forces about the point c S.No 1 3 Load Wup1 W6 Description Upward Pressure (ACEF) Weight of Toe slab Unit kN kN Total Maximum working moment Factored moment Thickness required Effective Thickness Provided Area of steel required Dia of bar Spacing required Distribution reinf: Dia of bar Spacing required Magnitude Vertical Horizontal 214.89 -9.38 205.52 79.48 119.23 0.19 0.46 612 25 100.00 552 16 200.00 Distance from point C 0.39 0.38 Moment about C 83.00 -3.52 79.48 kNm kNm m m mm2/m mm mm (Parallel to the length of retaining wall)

Ast3

Ast4

Area of steel provided Percentage of steel provided Check for Shear: (Toe Slab) Critical section for shear is at d distance from face of the stem. Shear Force Shear Stress Allowable shear stress

mm2/m mm mm 2 4908.739 mm /m 1.067 % i.e 29.80 kN 0.065 N/mm2 0.657 N/mm2 Safe

(Parallel to counterfort)

0.29 m from A

Design of Heel Slab: Maximum Bending moment acting on the toe slab is calculated by considering moments of all forces about the point b Weight of soil on strip Self weight of heel slab Total doward force Upward pressure Net Downward Pressure Maximum negative moment Factored Moment Depth Provided Area of steel requried Minimum reinforcement required Dia of bar Spacing required Percentage of reinforcement provided Distribution reinforcement: Area of steel required Dia of bar Spacing required Check for Shear: Shear force developed Shear stress developed Allowable shear stress Design of counterforts: Thickness of counterfort Top width of counterfort Bottom width of counterfort Inclination angle of counterfort Depth from face of the stem Effective depth of counterforts Maximum bending moment Factored Bending moment Area of steel required Min reinforcement required Dia of bars No. of bars Check for Shear: f n 144.00 kN/m2 12.5 kN/m2 156.50 kN/m2 -31.29 kN/m2 kN/m2 kNm kNm m 2 1109.00 mm /m 2 552 mm /m 25 mm 100.00 mm 1.07 % 187.79 140.84 211.27 0.46
2 552 mm /m 16 mm 200.00 mm

0.12% of c/s area

0.12% of c/s area

V v c

281.69 kN 0.56 N/mm2 0.66 N/mm2 Safe 0.40 0.5 4.25 25.11 3.36 3.86 2550.49 3825.74 m m m deg m m kNm kNm 2 2353 mm /m 2 3277.2 mm /m 32 mm 5 nos 0

Shear force Percentage of steel provided Allowable shear stress Curtailment of Counterfort bars: Half the bars shall be curtailed at distance of Connection between counterfort and stem: Horizontal force Factored Force Steel required Dia of bar required Spacing required Connection between counterfort and Heel slab:

d' V v Pt c

4.26 m 284.86 kN 0.18 N/mm2 0.26 % 0.37 N/mm2 Safe 2.83 m from top . 176.50 264.76 608.64 mm2/m 16 mm 325.00 mm 469.48 kN/m2 704.22 kN 1618.89 mm2/m 16 mm 100.00 mm

Tension transferred in 1m width of counterfort near the heel Factored force Steel required Dia of bar required Spacing required Design of shear Key: Co-efficient of passive pressure Upward pressure near the key Let depth of shear key Width of the shear key Passive pressure developed Total passive pressure Weight of earthfill in the key Self weight of the key FOS against sliding Cost Estimation: Cost compuatation for counterfort spacing S.No 1 2 3 4 5 6 7 Component Stem Base Slab Counter forts Steel in Stem Toe Slab Heel Slab Counterfort (1 No.) C/s area m 4.00 2.50 15.00
2

Kp P a Kp*P Pp *a Wa W

2.04 260.75 0.50 0.50 531.84 kN/m2 m m

kN/m2 265.92 kN 45 kN 702.50 kN 2.01

Thicness/Len gth m 3.00 3.00 0.40

Quantity

Rate

Cost Rs 54000.00 33750.00 27000.00 44813.688 9858.1293 47223.086 141010.82 357,656

m3 Rs/m3 12.00 4500.00 7.50 4500.00 6.00 4500.00 0.996 45000.00 0.219 45000.00 1.049 45000.00 3.134 45000.00 Total cost