You are on page 1of 6

KK Series 2011_Bitzer Platinum SeriesBrochure 22/06/11 12:02 PM Page 3

KK SERIES
INDUCED DRAUGHT HEAVY DUTY BLAST EVAPORATORS

KK Series

Quality
ISO 9001

CUT OFF AREA

KK Series 2011_Bitzer Platinum SeriesBrochure 22/06/11 12:02 PM Page 1

Features

KK Series Features:

J Six Modules - each with Nine Coil Options.

J Can be floor or ceiling mounted using the


universal top or bottom support legs.

J Individually circuited for each application.


J Simple direct lifting or ceiling mounting.
J Available in 3, 4, 5 or 6 fins per inch,
8, 6, 5 or 4 mm fin spacing.

J Steel support sections hot dipped galvanized.

J Air, hot gas and water defrost models.

J Adjustable pitch axial flow fans - constant air flow.

J Operating range -50C to +10C.

J Fans available for free discharge or 125 Pa


external pressure using upgraded motors.

J Fan motors prewired to a common terminal box.


J Low weight construction with aluminium casing.

B ITZER

KK Series 2011_Bitzer Platinum SeriesBrochure 22/06/11 12:02 PM Page 4

KK Series Blast Freezer/Chiller Evaporators


Specifications - Capacities based on -25C S.S.T. Coil
Coil
Model

KK12

KK14

KK24

KK28

KK36

KK42

Rows
Deep

Fin
Series
(F.P.I.)

R22

R507

R404A

R407B

6
6
6
6
8
8
8
10
10
6
6
6
6
8
8
8
10
10
6
6
6
6
8
8
8
10
10
6
6
6
6
8
8
8
10
10
6
6
6
6
8
8
8
10
10
6
6
6
6
8
8
8
10
10

6
5
4
3
5
4
3
4
3
6
5
4
3
5
4
3
4
3
6
5
4
3
5
4
3
4
3
6
5
4
3
5
4
3
4
3
6
5
4
3
5
4
3
4
3
6
5
4
3
5
4
3
4
3

13310
11784
10521
9153
15032
13421
11676
15132
13164
15761
13986
12459
10840
17801
15893
13827
17919
15589
26620
23568
21043
18307
30064
26849
23353
30263
26329
31524
27910
24919
21680
35602
31788
27655
35838
31179
39930
35353
31565
27461
45097
40265
35030
45395
39494
47286
41865
37379
32520
53404
47682
41483
53758
46769

12937
11454
10226
8897
14611
13045
11349
14708
12795
15320
13594
12110
10536
17303
15448
13440
17417
15153
25875
22908
20454
17794
29222
26097
22699
29416
25592
30641
27129
24221
21073
34605
30898
26881
34835
30306
38812
34363
30681
26692
43834
39138
34049
44124
38388
45962
40693
36332
31609
51909
46347
40321
52253
45459

12778
11313
10100
8787
14431
12884
11209
14527
12637
15131
13427
11961
10406
17089
15257
13274
17202
14965
25555
22625
20201
17575
28861
25775
22419
29052
25276
30263
26794
23922
20813
34178
30516
26549
34404
29932
38333
33939
30302
26363
43293
38654
33629
43579
37914
45395
40190
35884
31219
51268
45775
39824
51608
44898

12711
11254
10048
8741
14356
12817
11151
14451
12572
15052
13357
11898
10352
17000
15178
13205
17113
14887
25422
22507
20096
17483
28711
25641
22302
28901
25144
30105
26654
23798
20704
34000
30358
26411
34225
29776
38133
33762
30145
26225
43068
38453
33454
43352
37717
45158
39981
35697
31057
51001
45536
39616
51339
44664

Wa t t s @ 6 K T D

Air
Flow
Total
l/sec

3963

4623

7924

9245

11886

13867

No
of
Fans

Fan Motor Data (per motor)


Approx
Free Air
125Pa External Operating
Discharge
Resistance
Charge @25C
kW
F.L.C.* kW
F.L.C.* DX (R22)

2.2
2.2
1.5
1.5
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
3.0
2.2
2.2
2.2
1.5
1.5
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
3.0
2.2
2.2
2.2
1.5
1.5
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
3.0
2.2

4.52
4.52
3.25
3.25
4.52
4.52
4.52
4.52
4.52
4.52
4.52
4.52
4.52
4.52
4.52
4.52
6.2
4.52
4.52
4.52
3.25
3.25
4.52
4.52
4.52
4.52
4.52
4.52
4.52
4.52
4.52
4.52
4.52
4.52
6.2
4.52
4.52
4.52
3.25
3.25
4.52
4.52
4.52
4.52
4.52
4.52
4.52
4.52
4.52
4.52
4.52
4.52
6.2
4.52

3.0
3.0
3.0
2.2
4.0
3.0
3.0
4.0
3.0
4.0
3.0
3.0
3.0
4.0
4.0
3.0
5.5
4.0
3.0
3.0
3.0
2.2
4.0
3.0
3.0
4.0
3.0
4.0
3.0
3.0
3.0
4.0
4.0
3.0
5.5
4.0
3.0
3.0
3.0
2.2
4.0
3.0
3.0
4.0
3.0
4.0
3.0
3.0
3.0
4.0
4.0
3.0
5.5
4.0

6.2
6.2
6.2
4.52
8.1
6.2
6.2
8.1
6.2
8.1
6.2
6.2
6.2
8.1
8.1
6.2
8.4
8.1
6.2
6.2
6.2
4.52
8.1
6.2
6.2
8.1
6.2
8.1
6.2
6.2
6.2
8.1
8.1
6.2
8.4
8.1
6.2
6.2
6.2
4.52
8.1
6.2
6.2
8.1
6.2
8.1
6.2
6.2
6.2
8.1
8.1
6.2
8.4
8.1

5.4

6.8
8.6
5.9

8.2
10.0
10.0

13.2
16.8
11.8

15.4
19.0
14.5

19.5
24.5
17.2

22.7
28.6

Capacity Correction Factors

SUCTION TEMPERATURE(C)

-50

-40

-35

-30

-25

-20

-15

-10

-5

10

CAPACITY MULTIPLIER

0.82

0.92

0.94

0.97

1.0

1.03

1.06

1.09

1.12

1.15

1.18

1.21

B ITZER

KK Series 2011_Bitzer Platinum SeriesBrochure 22/06/11 12:02 PM Page 5

Physical Data
Model HKK - Hot Gas Defrost (Floor or Ceiling Mounted)

Dimensions (mm)
Model

All Models
A

2 Fan Models

Refrigerant Connections (mm)


Approximate
All
Drain
6
Row
8
Row
10
Row
Dry
Weight (kg)
Models
H Size Suct. HGas Suct. HGas Suct. HGas 6 Row 8 Row 10 Row

3 Fan Models

HKK12 1325

1050

1040

32

41.2

28.5

41.2

28.5

41.2

28.5

148

168

188

HKK14 1500

1228

1218

32

41.2

28.5

41.2

28.5

53.9

28.5

158

182

205

HKK24 2285

2015

1045

970

2005

32

53.9

34.9

53.9

34.9

53.9

34.9

286

326

366

HKK28 2645

2371

1223

1148

2356

32

53.9

34.9

53.9

34.9

53.9

34.9

306

353

399

HKK36 3255

2980

965

1045

970

2970

51

53.9

41.2

66.6

41.2

66.6

41.2

424

484

544

HKK42 3785

3514

1143

1223

1148

3504

51

66.6

41.2

66.6

41.2

66.6

41.2

454

526

594

Model WKK - Water Defrost (Floor or Ceiling Mounted)

Dimensions (mm)
Model

All Models
A

2 Fan Models
C

3 Fan Models
E

Approximate
Refrigerant
All
Connections (mm)
Dry Weight (kg)
Models Drain Defrost
Water
H
Size Conn. 6 Row 8 Row 10 Row 6 Row 8 Row 10 Row

WKK12

1325

1050

1040

60.3

32

41.2

41.2

41.2

148

168

188

WKK14

1500

1228

1218

60.3

32

41.2

41.2

53.9

158

182

205

WKK24

2285

2015

1045

970

2005

80

2 x 32

53.9

53.9

53.9

286

326

366

WKK28

2645

2371

1223

1148

2356

80

2 x 32

53.9

53.9

53.9

306

353

399

WKK36

3255

2980

965

1045

970

2970

100

3 x 32

53.9

66.6

66.6

424

484

544

WKK42

3785

3514

1143

1223

1148

3504

100

3 x 32

66.6

66.6

66.6

454

526

594

B ITZER

KK Series 2011_Bitzer Platinum SeriesBrochure 22/06/11 12:02 PM Page 6

APPLICATION DETAILS

Application Notes

Selection

Full Load Current


F.L.C.* is motor current as marked on motor rating plate and is at
standard air conditions of 20C and 1.2 kg/m 3, not operating
temperature.

Capacities of models that overlap, permit a more flexible and


economical selection, where the "LATENT LOAD" is low. The following
Table is a guide to selection of Fin Spacing.
Fin
Spacing

Power requirements vary directly as the air density ratio and/or


absolute temperature ratio.
Amps 2 = Amps1 x (P2 )

OR

Amps2 x Amps1 x

(P1 )

(273 + T1 )
(273 + T2 )

Defrost Water Requirement


Models 12 and 14 - 0.681 l/sec.
Models 24 and 28 - 1.361 l/sec.
Models 36 and 42 - 2.043 l/sec.

Latent
Load

Application

4 mm (6 FPI)

Air Defrost Light Duty Storage

5 mm (5 FPI)

Air Defrost Normal Duty Storage/ Freezing

6 mm (4 FPI)

Heavy Duty Storage Packaged Freezing

8 mm (3 FPI)

Extra Heavy Duty Storage Blast Freezing

Light
Normal
High
Heavy

Example
Air Throw (Free Discharge)
Air throw is a function of many factors. Larger fans, more per cooler,
several coolers grouped closely, air discharge close to a ceiling; all
improve the chance of air reaching the far end of a store.

Requirements
Blast Freezer -29C, Load (incl. fan motors) 37.0 kW,
S.S.T. -35C (6 KTD), required external resistance 120Pa,
Water Defrost.

Just as important, however, is the store geometry, aisle layout and


product loading.

Selection
Correction for -35C = 0.94 (1 R = 1.0638)
Where, 37.0 kW x 1.0638 = 39.36 kW.
Read directly from Capacity Table
Where, WKK36103 at 39.494 kW fitted with 3 x 2.2 kW fan motors.
New Current Draw of Fan Motor (at -35C)
(273 + 20)
Amps = 4.52 x (273 + -35)
= 5.56 Amps per motor.

Generally speaking, long air throws require significant separation


between the leaving and returning air streams. This allows each to
play its part in rotating the whole of the store air. Tall stores with
longitudinal aisles and coolers discharging at high level, present no
problems.
On low ceiling stores the coolers should be positioned for the leaving
and return air streams to be separated in the horizontal plane.
Most difficult are "tunnel" shaped rooms which can reduce the
potential air throw by a very high proportion. This may require special
arrangements such as ducting, false ceiling or "socks". All will require
some degree of external pressure at the fans.
KK Models
12 & 14
24 & 28
36 & 42

Approx. Air Throw (m)


13 to 19
18 to 27
24 to 36

Model Nomenclature
W

Defrost
Model
A = Air
H = Hot Gas
W = Water

KK Series

KK

42

Face Area

10

No. Rows

Fin Series

B ITZER

KK Series 2011_Bitzer Platinum SeriesBrochure 22/06/11 12:02 PM Page 2

BITZER Australia Pty Limited


134 Dunheved Circuit,
St Marys, NSW 2760
Australia
tel
+61 (2) 8801 9300
fax +61 (2) 9673 4698
info@bitzer.com.au

Other Products Available


PS Series Evaporator
Innovative design in Coil
Geometry
Powder Coated white panels
Internal Ripple Finned Tube
for higher heat transfer

Victoria
tel +61 (3) 8326 8200
fax +61 (3) 9310 2520

High quality sickle blade fans

Queensland
tel +61 (7) 3274 3620
fax +61 (7) 3274 3621

Cyclone Series Evaporator


Large capacity evaporators
Powder Coated white panels

North Queensland
tel +61 (7) 4728 3964
fax +61 (7) 4755 2910

Internal Ripple Finned Tube


for higher heat transfer
High quality 630mm and
800mm fans

South Australia
tel +61 (8) 8268 4500
fax +61 (8) 8268 4555

LCS Large Outdoor


Condensing Unit

Western Australia
tel +61 (8) 9359 2066
fax +61 (8) 9359 2077
BITZER New Zealand
BITZER Australia Pty Ltd
13b Airborne Rd
Albany 0632
North Shore City
New Zealand
tel +64 9 415 2030
fax +64 9 415 2031

V-shape condenser set


BITZER Octagon and
B5-Compressor Series
Standard version features
fully wired electrical panel

In the interest of continuous improvement BITZER reserves the right


to change the specifications or design of any of its products without
notice. The BITZER Symbol, name BITZER Group of Companies and
model names are registered trade marks. All products manufactured
are pending design and specification registration and must not be
copied or duplicated in any way.

www.bitzer.com.au
www.buffalotrident.com.au

ISSUE: JUNE 2010

You might also like