BBU3900 Installation Guide

HUAWEI TECHNOLOGIES Co., Ltd.

Content
Safety Information 1 1. Information About the Installation 2 2. Installing the BBU in the APM308 3. Installing the BBU in the APM30H 15 4. Installing the BBU in the APM30 (+24 V)17 5. Installing the BBU in the 19-Inch Cabinet 19 6. Installing the BBU on the Wall 23 7. Installing the BBU in the PS4890 Cabinet 28 8. Installing the BBU in the OMB Cabinet 33 9. Installing the BBU in the TMC 38 10. Installing the BBU in the TMC11H40 11. Checking the Power-On Status of the BBU 41 12. Reference 42

Safety Information
Following All Safety Precautions
Before any operation, read the instructions and precautions in this document carefully to minimize the possibility of accidents. The Danger, Caution, and Note items in the documents do not cover all the safety precautions that must be followed. They only provide the generic safety precautions for operations. When operating Huawei products and equipment, you must comply with safety precautions and special safety instructions related to corresponding equipment provided by Huawei. The safety precautions in the document are related to only Huawei products. Huawei is not liable for any consequence that results from the violation of universal regulations for safety operations and safety codes on design, production, and equipment use.

Complying with the Local Safety Regulations


When operating the device, comply with the local safety regulations. The safety precautions provided in the documents are supplementary. You must comply with the local safety regulations.

Qualified Personnel Only


The personnel in charge of installation and maintenance must be trained and master the correct operating methods and safety precautions before beginning work.

Symbols
This symbol indicates that casualty or serious accident may occur if you ignore the safety instruction. This symbol indicates that serious or major injury may occur if you ignore the safety instruction. This symbol indicates that the operation may be easier if you pay attention to the safety instruction.

Safety of Personnel
The high voltage power supply provides power for running the system. Direct contact with the high voltage power supply or contact through damp objects may result in fatal danger. Non-standard and improper high voltage operations may result in fire and electric shock. In a thunderstorm, do not perform operations on high voltage and AC power supply facilities or on a steel tower and mast. Ground the device before powering on the device. Otherwise, the personnel and device are in danger. Power off the device before performing operations on the power supply equipment. High power radio-frequency signals are harmful to human body. Before installing or maintaining an antenna on a steel tower or mast with a large number of transmitter antennas, the operator should coordinate with all parties to ensure that the transmitter antennas are shut down. When handling optical fibers, do not stand close to, or look into the optical fiber outlet with unaided eyes. Protect yourself when drilling holes. Flying dust may hurt your eyes or you may inhale the dust. Power off the batteries before connecting the cables to the batteries. Otherwise, casualties may occur. When working at a height, be cautious about falling objects.

Device Safety
Check the electrical connection of the device before operation and ensure that the device is reliably grounded. The static electricity generated by the human body may damage the electrostatic sensitive components on the circuit board, such as the large-scale integrated circuit (LIC). Wear an ESD wrist strap or ESD gloves when performing the operation. When working on batteries, take measures to prevent short circuits in the batteries and electrolyte spill/loss. The electrolyte may erode metal and boards, or even cause rust of the equipment or short circuits in the boards. The BTS3900A must be powered on within one week after installation.
Copyright Huawei Technologies Co., Ltd. 2009. All rights reserved.

1 Information About the Installation


a
Installation Tools

Installation Scenarios
2.APM30H

1.APM30

BBU

BBU

3.TEC

4.TEC11H

BBU

BBU

Installation Scenarios
6.PS4890

5.APM30 (+24V)

BBU BBU

7. In OMB cabinet

8.In other 19-inch cabinet

9.On the Wall

BBU

BBU

BBU

BBU Hardware and Cables

1. Appearance of the BBU (Unit: mm)

2. Cable connections of the BBU

Alarm Equipment

Monitoring Equipment

Power System

BBU Power Cable E1 surge protection transfer cable E1 Cable Monitoring Cable

Alarm Cable CPRI Optical FE cable FE surge protection transfer cable

BBU Hardware and Cables

3. Configuration Principles of the BBU Boards

Board

Mandatory /Optional
Mandatory

Full Configuration
2

Installation Slot
S6 and S7

Remarks

WMPT

Preferentially configured in Slot 7. Preferentially configured in Slot 3, then Slot 2, at last Slot 0,1. Preferentially configured in PWR2. Only in the FAN slot. Preferentially configured in Slot 4, 5. Preferentially configured in Slot 4. Preferentially configured in Slot 4. Preferentially configured in PWR1.

WBBP

Mandatory

S0 to S3

UPEU

Mandatory

PWR1 and PWR2 FAN S0 to S5

UBFA UTRP

Mandatory Optional

1 5

UELP

Optional

S0 and S4

UFLP

Optional

S0 and S4

UEIU

Optional

PWR1

Procedure

Installing the BBU in the APM30 a


Cable connections

NO.

Cable From...

Installation Position To ... PWR on BBU INSIDE on UELP Transmission equipment MON1on BBU CPRI on RRU

1 2 3 4 5

BBU power cable E1 transfer cable E1cable Monitoring cable CPRI

LOAD3 on PDU E1/T1 on WMPT OUTSIDE on UELP TX/RX on APMI CPRI on BBU

Installing BBU

1 Install the mounting ears at both sides of the BBU reversely.

PDU

BBU
2 Slide the BBU case into the cabinet. 3 Check the DIP switches (see appendix).

Installing cables
1. Install power cable.

Connect the OT terminal of the power cable to the LOAD3 terminal of the PDU, and then fix the 3V3 connector of the power cable to the PWR port on the BBU. LOAD3 NEG(-) RNT(+)

PWR

Installing the BBU cables

2. Install optical cables.

Connect one end of the optical cable to CPRI0, CPRI1, or CPRI2 on the WBBP. Then, connect the other end to the RRU. Insert the optical module into CPRI0, CPRI1, or CPRI2. Turn outwards the puller on the optical module.

Optical module Puller

Remove the dustproof caps from the optical connectors. Insert the optical connector at one end of the CPRI optical cable into the optical module. lead the CPRI optical cable out of the cabinet along the left side of the cabinet. Wrap the fiber tail with the winding pipe till the first cable tie. The TX port on the BBU is connected to the RX port on the RRU. The RX port on the BBU is connected to the TX port on the RRU.
Optical cable connector Winding pipe

10

Installing the BBU cables


Fix the DB25 connector of the E1 transfer cable to the INSIDE port on the UELP and the DB26 connector to the E1/T1 port on the WMPT.

3. Install the E1 transfer cable.

4. Install the E1 cable.

Cabling the E1 cable. Fix the DB26 connector of the E1 cable to the OUTSIDE port on the UELP. Strip the jacket off the E1 cable near the grounding point at the lower right corner of the cabinet to expose the shielding layer (25mm)

OUTSIDE

INSIDE

E1/T1

E1 transfer cable

Thread the E1 cable through the grounding clip. Then, tighten the screw on the grounding clip to make the shielding layer of the E1 cable in full contact with the grounding clip. Finally, connect the PGND cable on the grounding clip to the grounding bolt of the APM30.

Shielding layer of the E1 cable E1cable

11

Installing the BBU Cables


5. Install the FE transfer cable (FE transmission mode).

Connect one end of the FE transfer cable to the FE0 port near the INSIDE label on the UFLP and the other end to the FE0 port on the WMPT.

6. Install the FE cable (FE transmission).

Connect one end of the FE cable to the FE0 port near the OUTSIDE label on the UFLP. Then, lead the other end out of the cabinet along the right side of the cabinet. FE transfer cable FE cable Strip the jacket off the FE cable near the grounding point at the lower right corner of the cabinet to expose the shielding layer (25mm)

Thread the FE cable through the grounding clip. Then, tighten the screw on the grounding clip to make the shielding layer of the FE cable in full contact with the grounding clip. Finally, connect the PGND cable on the grounding clip to the grounding bolt of the APM30. Shielding layer of the FE cable

12

Installing the BBU cables


7. Install the monitoring signal cable between the APMI and the BBU.

Fix the RJ45 connector at one end of the cable to the MON1 port on the UPEU. MON1
Monitoring signal cable between the APMI and the BBU

RJ45
8. Install the external alarm cable.

EXT-ALM1 External alarm cable

Connect one end of the alarm cable to the EXT-ALM port on the UPEU, and the other end to the associated alarm device. The port on the external alarm device is added depending on field requirements.

9. Install the EMUA monitoring signal cable.

When the MON0 port on the BBU is available, fix the RJ45 connector of the EMUA monitoring signal cable to the MON0 port on the UPEU, and the DB9 connector to the corresponding port on the EMUA.

MON0

RS485

13

Installing the BBU cables


b. When the MON0 port on the BBU is unavailable, cut off the RJ45 connector of the EMUA monitoring signal cable, and then connect the four exposed bare wires to the RX+, RX-, TX+, and TX- ports on the APMI. For the relationship between the ports and wires. Fix the DB9 connector to the corresponding port on the EMUA.

RS485

EMUA monitoring signal cable Pin on the RJ45 Connector X1.1 X1.2 X1.4 X1.5 Pin on the DB9 Male Connector X2.3 X2.7 X2.2 X2.6 White Orange Blue White Twisted pair Twisted pair TX+ TXRX+ RXColor Type Port on the APMI

14

3 Installing the BBU in the APM30H a


BBU Cable Connections

The procedure for installing the BBU case in the APM30H is the same as that in the APM30. For details, see pages 814. The following figure shows the cable connections of the BBU. Page 16 shows how to install the monitoring signal cable between the HEUA and the BBU in the APM30H.

No.

Cable

Installation Position One end is connected to... The other end is connected to... PWR port on the BBU INSIDE port on the UELP External transmission device MON1 port on the BBU

1 2 3 4

BBU power cable E1 transfer cable E1 cable Monitoring signal cable CPRI optical cable

LOAD3 terminal of the PDU E1/T1 port on the WMPT OUTSIDE port on the UELP COM IN port on the HEUA

CPRI port on the BBU

CPRI port on the RRU

15

Installing the Monitoring Signal Cable between the HEUA and the BBU

HEUA COM IN MON1

UPEU on the BBU

16

4 Installing the BBU in the APM30 (+24 V) a


BBU Cable Connections

The procedure for installing the BBU in the APM30 (+24 V) is the same as that in the APM30. For details, see pages 814. The following figure shows the cable connections of the BBU. Page 18 shows how to install the monitoring signal cable of the cabinet.

No.

Cable

Installation Position One end is connected to... The other end is connected to... PWR port on the BBU INSIDE port on the UELP External transmission device MON1 port on the BBU

1 2 3 4

BBU power cable E1 surge protection transfer cable E1 cable Monitoring signal cable CPRI optical cable

LOAD3 terminal of the PDU E1/T1 port on the WMPT OUTSIDE port on the UELP COM IN port on the HEUA

CPRI port on the BBU

CPRI port on the RRU

17

Installing the Monitoring Signal Cable of the Cabinet

Pin assignment of the monitoring signal cable of the cabinet Pin on the RJ45 Connector X1.1 X1.2 X1.3 X1.6 X1.5 X1.4 X1.7 X1.8 Pin on the RJ45 Connector X2.1 X2.2 X2.3 X2.6 X2.5 X2.4 X2.7 X2.8 18 Wire Color Wire Type

White/orange Orange White/green Green White/blue Blue White/brown Brown

Twisted pair

Twisted pair

Twisted pair

Twisted pair

5 Installing the BBU in the 19-Inch Cabinet a


BBU Cable Connections

No.

Cable From...

Installation Position To... PWR port on the BBU

BBU power cable E1 cable FE cable (optional) Monitoring signal cable CPRI optical cable

External power supply

2 3

External transmission device External transmission device

E1/T1 port on the WMPT FE0 port on the WMPT

External monitoring device

MON/ALM on the BBU

CPRI port on the RUU

CPRI port on the BBU

19

Space Requirements

1. 25 mm on the left of the BBU for ventilation 2. 25 mm on the right of the BBU for ventilation 3. 70 mm in front of the BBU for cabling 4. 800mm for maintenance

Installing the BBU Case

Slide the BBU case into the cabinet. Then, tighten the four M6 screws.

20

Installing BBU Cables


Grounding bolt on the right side of the BBU

1 Install the PGND cable.

PGND cable
2 Install the power cable.

PWR

3 Install the signal cable.

EXT-ALM0

MON1

21

Installing the BBU Cables


4 Install the CPRI optical cable and the E1 cable.

E1/T1

Insert the optical module into the CPRI0, CPRI1, or CPRI2 port. Turn outwards the puller on the optical module.

Optical module Puller Remove the dustproof caps from the optical connectors. Insert the optical connector at one end of the CPRI optical cable into the optical module. Lead the CPRI optical cable out of the cabinet along the left side of the cabinet.

22

6 Installing the BBU on the Wall a


BBU Cable Connections

RRU power cable CPRI optical cable BBU power cable DCDU-03C PGND cable

TO RRU

23

Space Requirements

DCDU-03C BBU

The DCDU is installed near the BBU.

Installing the BBU Case

1 Install the mounting ears for wall installation.

Mounting ear on the BBU case Mounting ear for wall installation

24

Installing the BBU Case


2 Place the BBU against the wall, and then use the marking pen to mark the holes of the mounting ears for wall installation.

Wall

BBU

3 Install the expansion bolts.

25

Installing the BBU Case


5 Mount the BBU on the wall.

Flat washer Spring washer

Installing the DCDU-03C Case


2 Place the DCDU-03C against the wall, and then use the marking pen to mark the anchor points of the mounting ears for wall installation.

1 Turn the mounting ears on the DCDU-03C by 90 degrees.

26

Installing the DCDU-03C Case

3 Install the expansion bolts.

4 Mount the DCDU-03C on the wall.

27

7 Installing the BBU in the PS4890 Cabinet


a
BBU Cable Connections

No.

Cable From...

Installation Position To...


PWR port on the BBU

1 2 3 4

BBU power cable E1 cable

LOAD6 terminal on the DCDU External transmission device External transmission device RS232/RS422 port on the PMU

E1/T1 port on the WMPT

BBU alarm cable (optional) Monitoring signal cable between the PMU and the BBU CPRI optical cable

ALM port on the UPEU

MON0 port on the BBU

CPRI port on the RRU

CPRI port on the BBU

28

Installing the BBU

Slide the BBU case into the PS4890 cabinet. Then, tighten the four M6 screws.

29

Installing the BBU Cables


1 Install the power cable.

LOAD 6

PWR

30

Installing the BBU Cables


2 Install the signal cable.

Install the BBU alarm cable (optional). Install the monitoring signal cable between the PMU and the BBU.

RS232/RS422

EXT ALM1

MON0

31

Installing the BBU Cables


3 Installing the CPRI optical cable and the E1 cable.

Insert the optical module into the CPRI0, CPRI1, or CPRI2 port. Turn outwards the puller on the optical module.

Optical module Puller

E1/T1

Remove the dustproof caps from the optical connectors. Insert the optical connector at one end of the CPRI optical cable into the optical module. lead the CPRI optical cable out of the cabinet along the left side of the cabinet.

32

8 Installing the BBU in the OMB Cabinet a


BBU Cable Connections

No.

Cable

Installation Position From... To... Grounding bar of the OMB cabinet DC input terminal of the DCDU PWR port on the BBU

PGND cable

External grounding bar

Input power cable of the OMB

External DC power supply

BBU power cable

LOAD6 output terminal on the DCDU E1/T1 port on the WMPT OUTSIDE port on the UELP CPRI port on the BBU

4 5 6

E1 transfer cable E1 cable CPRI optical cable

INSIDE port on the UELP External transmission device CPRI port on the RRU

33

Installing the BBU


Slide the BBU case into the OMB cabinet gently. Then, tighten the four M6 screws.

Installing the BBU Cables

1 Install the PGND cable of OMB Cabinet.

34

Installing the BBU Cables

2 Install the input power cable.

3 Install the CPRI optical cable. 1. Insert the optical module into the CPRI0, CPRI1, or CPRI2 port. 2. Turn outwards the puller on the optical module.

Optical module Puller


3. Remove the dustproof caps from the optical connectors. 4. Insert the optical connector at one end of the CPRI optical cable into the optical module. lead the CPRI optical cable out of the cabinet along the left side of the cabinet.

35

Installing the BBU Cables

4 Install the E1 cable (E1 transmission).

E1/T1 INSIDE

36

8 Installing the BBU in the OMB Cabinet b


Installing the BBU Cables
LOAD6

5 Install the BBU power cable.

6 Install the FE cable (FE transmission).

37

9 Installing the BBU in the TMC a


BBU Cable Connections

No.

Cable From...

Installation Position To...


PWR port on the BBU INSIDE port on the UELP External transmission device ALM1 port on the BBU

1 2 3 4

BBU power cable E1 transfer cable E1 cable Monitoring signal cable CPRI optical cable

LOAD6 terminal of the PDU E1/T1 port on the WMPT OUTSIDE port on the UELP Wiring terminal of cabinet monitoring CPRI port on the BBU

CPRI port on the RRU

38

Installing the BBU

Slide the BBU case into the TMC cabinet. Then, tighten the four M6 screws.

Installing the BBU Cables


APMI Door status sensor

Installing the TMC alarm cable: a. Fix the RJ45 connector at one end of the alarm cable to the EXT_ALM1 port on the BBU. b. Connect the two bare terminals X1.4 (blue) and X1.5 (white) to the alarm wiring terminals on the door status sensor. c. Connect the two bare terminals X1.1 (white) and X1.2 (orange) to the OUT+ and OUT- alarm wiring terminals on the APMI. d. Connect the two bare terminals X1.3 (white) and X1.6 (green) to the alarm wiring terminals on the DCDU.

Wiring terminal of DCDU surge protection

39

10 Installing the BBU in the TMC11H a


BBU Cable Connections

No.

Cable

Installation Position From... To...


CPRI port on the RRU

CPRI optical cable E1 transfer cable E1 cable BBU power cable Monitoring signal cable

CPRI port on the BBU

2 3 4

E1/T1 port on the WMPT OUTSIDE port on the UELP LOAD6 terminal on the PDU

INSIDE port on the UELP External transmission device PWR port on the BBU

Wiring terminal of cabinet monitoring

MON1 port on the BBU

40

11 Checking the Power-On Status of the BBU


Procedure for checking the power-on status of the BBU:

41

12 Reference
a
Cable PGND cable

Cable List
Connector OT terminal OT terminal Connects to Grounding bolt of the BBU3900 Protection grounding bar

BBU power cable

3V3 connector Bare wire. The connector needs to be made on site according to the field requirements. (The following figure shows the BBU power cable by taking OT terminals as an example.)

PWR port on the UPEU External power supply

CPRI optical cable

DLC connector

Connect the fiber tails labeled 1A and 1B to the CPRI_W port on the RRU Connect the fiber tails labeled 2A and 2B to one of the CPRI0 to CPRI3 ports on the WBBP

DLC connector

E1 cable

DB26 male connector

E1/T1 port on the GTMU or WMPT, or OUTSIDE port on the UELP Peer device

The connector needs to be made on site according to the field requirements.

42

12 Reference
c a
Cable List
Connector DB26 male connector DB25 male connector Connects to PWR port on the UPEU E1/T1 port on the GTMU or WMPT Cable E1 transfer cable

FE cable

RJ45 connector RJ45 connector

FE0 port on the WMPT Routing equipment

FE transfer cable

RJ45 connector RJ45 connector

FE0 port on the WMPT FE0 port near the INSIDE label on the UFLP

Monitoring signal cable between the PMU and the BBU

RJ45 connector RJ45 connector

RS232/RS422 port on the PMU MON port on the BBU

43

12 Reference
b
Engineering Specifications of the BBU
Item Dimensions Weight Input voltage Specification 86 mm (height) x 442 mm (width) x 310 mm (length) Typical configuration: 7 kg; full configuration: 11 kg 48 V DC or +24 V DC

Checking the DIP Switches of the BBU


Remove the BBU boards.

Check the DIP switch settings of the WMPT, GTMU, UTRP, and UELP.

Wear an ESD wrist strap or a pair of ESD gloves when performing operations related to the boards, as shown in the figure below.

ESD strap

ESD gloves

44

12 Reference
c
Setting the DIP Switches
Set the DIP switches of the BBU. Settings of the DIP switches on the UELP

Settings of the DIP switches on the WMPT

Settings of the DIP switches on the UTRP

Reinstall the boards.

45

12 Reference
ed
Pin Assignment of the BBU Signal Cables
75-ohm E1 cable Pin on the DB26 Male Connector X1.1 X1.2 X1.3 X1.4 X1.5 X1.6 X1.7 X1.8 X1.19 X1.20 X1.21 X1.22 X1.23 X1.24 X1.25 X1.26 Tip Ring Tip Ring Tip Ring Tip Ring Tip Ring Tip Ring Tip Ring Tip Ring 8 6 4 2 7 5 3 1 RX1+ RX1RX2+ RX2RX3+ RX3RX4+ RX4TX1+ TX1TX2+ TX2TX3+ TX3TX4+ TX4Wire Type Coaxial SN. Label

46

12 Reference
d
Pin Assignment of the BBU Signal Cables
120-ohm E1 cable Pin on the DB26 Male Connector X1.1 X1.2 X1.3 X1.4 X1.5 X1.6 X1.7 X1.8 X1.19 X1.20 X1.21 X1.22 X1.23 X1.24 X1.25 X1.26 Blue Twisted pair White Orange White Green Twisted pair White Brown Twisted pair White Grey Twisted pair White Blue Twisted pair Red Orange Twisted pair Red Green Twisted pair Red TX4TX3TX4+ TX2TX3+ TX1TX2+ RX4TX1+ RX3RX4+ Twisted pair RX1RX2+ RX2RX3+ RX1+ Wire Color Wire Type Label

47

12 Reference
d
Pin Assignment of the BBU Signal Cables
FE cable Pin on the RJ45 Connector X1.2 X1.1 X1.6 X1.3 X1.4 X1.5 X1.8 X1.7 Wire Color Wire Type Pin on the RJ45 Connector X2.2 X2.1 Twisted pair X2.6 X2.3 Twisted pair X2.4 X2.5 Twisted pair X2.8 X2.7

Orange White/orange Green White/green Blue White/blue Brown White/brown

Twisted pair

Monitoring signal cable between the APMI and the BBU Pin on the RJ45 Connector Wire Color Pins on the X2, X3, X4, and X5 X2 Twisted pair X1.2 Orange X3 Twisted pair X1.4 Blue X4 Twisted pair X1.5 White X5 Twisted pair 48 RXRX+ TXWire Type Port on the APMI

X1.1

White

TX+

12 Reference
d
Pin Assignment of the BBU Signal Cables

EMUA monitoring signal cable Pin on the RJ45 Connector Pin on the DB9 Male Connector X2.3 Wire Color Wire Type Port on the APMI

X1.1

White

Twisted pair

TX+

X1.2

X2.7

Orange

Twisted pair

TX-

X1.4

X2.2

Blue

Twisted pair

RX+

X1.5

X2.6

White

Twisted pair

RX-

Alarm cable Pin on the RJ45 Connector X1.1 X1.2 X1.3 X1.6 X1.5 X1.4 X1.7 X1.8 Pin on the RJ45 Connector X2.1 X2.2 X2.3 X2.6 X2.5 X2.4 X2.7 X2.8 White/orange Orange White/green Green White/blue Blue White/brown Brown Twisted pair Twisted pair Twisted pair Twisted pair Wire Color Wire Type

49

HUAWEI TECHNOLOGIES CO., LTD.


Huawei Industrial Base Bantian Longgang Shenzhen 518129 Peoples Republic of China www.huawei.com