You are on page 1of 40

EXCELL PRECISION CO., LTD.

FB530/FB630
(Conversion)Dot Matrix
Printer Indicator
User Manual










EXCELL PRECISION CO., LTD. 2009. All rights reserved worldwide.

The information contained herein is the property of EXCELL PRECISION CO., LTD. and is
supplied without liability for errors or omissions. No part may be reproduced or used except as
authorized by contract or other written permission. The copyright and the foregoing restriction on
reproduction and use extend to all media in which the information may be embodied.



FB530/FB630 ZSME300000159

1
EXCELL PRECISION CO., LTD.
Table of Contents
Instructions for Use .................................................................................................................... 2
Preparing to Use the Indicator ................................................................................................... 2
Chapter 1 General Introduction ................................................................................................. 3
1-1 Display Description........................................................................................................... 3
1-2 Power Description............................................................................................................. 4
1-3 Keypad Description........................................................................................................... 5
Chapter 2 General Operation Description................................................................................. 6
2-1 Backlight Function ............................................................................................................ 6
2-2 Weighing Mode.................................................................................................................. 6
(1). Units Selection............................................................................................................... 6
(2). Check Weighing Mode .................................................................................................. 6
(3). Totalizing........................................................................................................................ 8
(4). Zero Function................................................................................................................. 8
(5). Tare Function................................................................................................................. 9
(6). Printing Function (only for FB model) ....................................................................... 10
2-3 Counting Function .......................................................................................................... 12
(1). Sampling ...................................................................................................................... 12
(2). Check Weighing........................................................................................................... 12
(3). Totalizing...................................................................................................................... 12
Chapter 3 General Function Setting ........................................................................................ 13
Check weighing configuration ............................................................................................. 14
RS-232 Interface (option) and Mini Printer Output Setting ................................................ 15
Exit Setting Mode .................................................................................................................. 25
Weight Hold Mode setting .................................................................................................... 26
G value Calibration................................................................................................................ 28
Load Cell Pin Description (input signal) ................................................................................. 29
Option Function Description.................................................................................................... 30
Error Messages ......................................................................................................................... 30
Appendix 1 ASCII Code Table ............................................................................................... 31
Appendix 2 7-Segment Display Characters ......................................................................... 32
Appendix 3 Printer Installation.............................................................................................. 33
Appendix 4 Load Hook Installation....................................................................................... 34






FB530/FB630 ZSME300000159

2
EXCELL PRECISION CO., LTD.








Instructions for Use
1. The indicator should not be drenched by rain or water. (If it gets wet carelessly, please
wipe it dry with a cloth. If its operation is abnormal, please send it to our distributor for
service.
2. Please keep the indicator in a cool and dry place. Do not store at high temperatures or
humid places.
3. Please keep the indicator clean and free from insect infestation.
4. To avoid impact and it is to be used under designated pressure (the weight put on the
platter can not exceed the maximum capacity of the indicator)
5. If the indicator is not going to be used for some time, please clean it and store it in a
plastic bag in dry condition. A desiccant sachet may be included to prevent moisture from
building up. The internal rechargeable battery should be recharged every three months.
6. Any suggestion for the product is warmly welcome.


Preparing to Use the Indicator
1. Put the indicator on a firm and flat surface for accurate weighing reading. Adjust the four
leveling feet to get the leveling bubble at the center of the circle.
2. The indicator must be used under a stable temperature and stable air flow. Avoid direct
sunlight onto the indicator or near the air-conditioning outlet.
3. Indicator must be used under individual socket to avoid the interference of other electric
appliances.
4. Remove any weight that might be on the platter before the indicator is switched on.
5. The indicator requires 15 ~ 20 minutes warm up before operation to ensure best
accuracy.
6. Please note that when symbol appears on the screen, the indicator needs to be
recharged.




Thank you for purchasing EXCELL (Conversion)
Dot Matrix Printer Indicator. To guide you to use
our product correctly, please read the user manual
carefully to avoid mis-operating this product.


FB530/FB630 ZSME300000159

3
EXCELL PRECISION CO., LTD.
Chapter 1 General Introduction

1-1 Display Description













Changes of Range indication mode
The indicator with 2-segment specification:
6 is Range 1 5 is Range 2



: High limit value

: OK value (The value between HI and LO limit value)

: Low limit value
: kg or g unit
: Pound unit

: Taiwan and Hong Kong units

: Counting mode indication

: Percentage

: Zero indication

: Net weight indication

: Low battery power indication
1
: Stable indication
2
: Pretare mode indication
3
: Accumulation mode indication
4
: Printer ready indication (Mini Printer connection)
5
: Samples insufficient indication
6
: Unit weight insufficient indication
7
: Viss unit (Burma unit)
1 2 3 4 7 5 6


FB530/FB630 ZSME300000159

4
EXCELL PRECISION CO., LTD.
1-2 Power Description
Power Selection
1. 6 V / 4 Ah Rechargeable battery
2. 110 / 220 V 15%AC Main power
Recharge Voltage
1. AC 110 V +10% , -15%
2. AC 220 V +10% , -15%
Power Consumption
State Power Consumption
Continue Operation
Time
do not print
(indicator + Load Cell + 2 sides
backlight + Mini Printer)
Less than 55 mA Over 70 hours With a load cell
(350 )
printing
(indicator + Load Cell + 2 sides
backlight + Mini Printer)
Less than 350 mA Over 10 hours
(indicator + Load Cell) 26 mA About 180 hours
(indicator + Load Cell + front
display backlight)
32 mA About 140 hours Without a
printer
(indicator + Load Cell +rear
display backlight)
40 mA About 110 hours
Only RS-232
Card
About 20 mA

Low Power Alarm
Please note when the ( ) symbol keeps flashing on the left down corner of the display, the
batteries should be charged.
_ The indicator will turn off automatically after 5 ~ 10 hours (approximately 1 ~ 2 hours with
backlight on), when the low battery warning symbol shows up. The indicator must be fully
charged, before operating again.
_ When the low battery warning symbol shows up, please charge the indicator immediately for
fear of weight instability.
_ The indicator becomes unstable because of the large power consumption. Not be allowed
taking off the battery when equipped with mini printer.
EEPROM Power (for model with mini printer)
When using the rechargeable battery but AC power and the voltage is below 3 V, the data of
date, time, etc in RTC IC will disappear in 24 hours.


FB530/FB630 ZSME300000159

5
EXCELL PRECISION CO., LTD.
1-3 Keypad Description


: Press this key to select the required unit from the preset units.

:

Press this key to preset the HI, OK, LO value.

:

Press this key to accumulate the weight value or others.

:

Press this key to deduct the container weight.

:

Press this key to preset tare value.


:
Press this key to recall the accumulation value, preset value and pretare value.


:
Press this key to clear the accumulation value, preset value and pretare value.

:

Press this key to zero the indicator.

:

Press this key to confirm.

:

Press this key to light up the backlight.

:

Press this key to enter into counting mode.

:

Press this key to sample.

:

Press this key to print the total data.

:

Press this key to input the numbers (0 ~ 9).

:

Press this key to advance the paper.







FB530/FB630 ZSME300000159

6
EXCELL PRECISION CO., LTD.
Chapter 2 General Operation Description
2-1 Backlight Function
Press key to choose the display backlight mode:
. Auto Backlight mode. When the weight is over 10d or any key is
pressed, the display backlight will be switched on. When the weight
returns to zero (the weight on platform is less than 10d), the display
backlight will switch off after 10 seconds.
. Display backlight is on all the time.
. Display backlight is off.
2-2 Weighing Mode
(1). Units Selection
The selected unit will be memorized when you turn the indicator off. And the memorized unit
will appear after you turn on the indicator next time.
(2). Check Weighing Mode

1. Preset High limit, Low limit and Beeper value operation
Use and key to preset values.

For example:
Preset Low limit ( Low limit >10d ) e.g. Low limit = 20 kg
Press key the display shows .
Press key 1 time the display shows .
Press key 2 times the display shows .
Press key 4 times the display shows .

Preset High limit ( High limit Low limit ) e.g. High limit = 25 kg
Press key 1 time the display shows .
Press key 1 time the display shows .
Press key 2 times the display shows .
Press key 1 time the display shows .
Press key 5 times the display shows .
Press key 3 times the display shows .

Preset Beeper value ( Refer to Note ) e.g. Beeper value = 22
Press key 1 time the display shows
Press key 2 times the display shows
Press key 1 time the display shows
Press key 2 times the display shows
Press key 1 times the display shows .





FB530/FB630 ZSME300000159

7
EXCELL PRECISION CO., LTD.
_ Preset Single point (preset low limit only):
After preset low limit procedures is completed and the display shows . ,
then press key again, the display shows . . This means that the preset single
point procedure is completed.
NOTE
_ _ _ x x


A B
A Setting for the status that LCD is on and the beeper beep:
0 = when stable, the beeper beeps and LCD is on.
1 = when stable, the beeper beeps; whether stable or not, LCD is on.
2 = whether stable or not, the beeper beeps and LCD is on.
B Setting for the beep status:
0 = No beep
1 = OK (when the weight is over Low Limit & under or equal to High Limit.), the
beeper beeps.
2 = When the weight is under or equal to Low Limit & over High Limit, the beeper
beeps.
_ Under Status in Preset Low Limit (preset single point only)
The BEEP, LCD mode should be fixed as follows:








When over Low Limit, the beeper beeps and is off
Whether stable or not, the beeper beeps and LCD indication is on
_ LCD indication:


= ======
10d Low Limit High Limit
To exit preset mode, please press key.

2. Recall Check-weighing Values
Press key then press key Recall Low limit value
Then press key again Recall High limit value
Then press key again Recall Beeper value
Then press key again Back to the beginning

3. Clearing Check-weighing Values
Press key then press key, and then press key Recall Low limit value
Then press key again Clear High limit value and Beeper value
Press key then press key 6 times continuously Clear all values


FB530/FB630 ZSME300000159

8
EXCELL PRECISION CO., LTD.

(3). Totalizing
1. Weight Totalizing
Place goods on the platter, after stable and press key to save the weight value.
Then the display shows the total number of additions and the totalized weight value.
And the (M+) indication will flash on the display. The indicator will recover to show the
weight value of the goods on the platter after 3 seconds and the (M+) indication is on.

_ The indicator allows the next totalizing operation, even when the weight value does not
return back to zero. The key is functional, when the weight value changes by more
than 10d. The indicator will save the totalized weight value after the weight is stable.
_ The indicator can totalize positive or negative weight but cant do both at the same time.
The totalized weight store must be reset to zero before it is possible to select positive or
negative totalizing mode.
_ The totalizing function can be used up to a maximum of 9999 times before it must be reset.
The totalizing display is limited to 6 digits maximum.
_ When totalizing, RS-232 and Mini Printer will also output. ( Refer to F5 setting)

2. Clear Totalized Weight Values
Press then key to clear all totalized weight values.
When changing between weighing and counting mode, or selecting weighing unit, the
indicator will automatically clear all the totalized weight values.
The indicators will automatically clear all the totalized weight values after turning on.

3. Recall Totalized Weight Values

Press key to display the total number of additions and the totalized weight value.
And the (M+) indication will flash on the display. The indicator will return to the weighing
mode after 3 seconds.
_ The indicator will not display the negative sign - for negative totalized weight values when
recalling a totalized weight value, but when printing, the negative sign - will be printed out
(transmitted serially) for each negative weight and negative totalized weight.

(4). Zero Function
Press key to re-zero the display with no load on the platter. When zero is set, the
( ) symbol will be displayed.



FB530/FB630 ZSME300000159

9
EXCELL PRECISION CO., LTD.
(5). Tare Function
1. When the weight of the container is unknown ( )
O Place the container on the platter, after stable and press key, the weight value
returns to zero and net indication ( ) is on.
O Place goods into the container, then the indicator shows the net weight of goods.
O Clear tare value
When removing the container and goods, the display shows the negative weight value of
the container. Then press key to clear tare value. The indicator returns to zero and
net indication ( ) is on.
O Recall tare value
Press then key the display shows tare value

_ Multiple tare operation Users can continuously increase or decrease the tare value by
pressing the key.
_ The total tare value (tare value + pre-set tare value) can equal the full capacity of the indicator.

2. When the weight of the container is known ( )
O Press key and the display shows . .
Use and keys to input weight value of the container. After finishing the
procedures, the net indication ( ) and pretare indication is on.
O Place goods into the container, then the indicator shows the net weight of goods.
O Clear pretare value
Press then key, and then press key to clear pretare value.
When the indicator returns to zero, net indication ( ) and pretare indication are
off.
O Recall pretare value
Press then key the display shows pretare value


_ In Tare mode, the Preset tare function is disabled.
_ The indicators with two weighing ranges can NOT pre-set the tare value larger than the first
weighing range. For example: a 30 kg indicator is set by two weighing ranges. The first range
is 0 to 15 kg, and the second range is 15 to 30 kg. The pre-set tare value can not be larger
than 15 kg.




FB530/FB630 ZSME300000159

10
EXCELL PRECISION CO., LTD.
(6). Printing Function (only for FB model)
F5 Function
Press key
Press key
Press key twice
after zeroing
RS-232 closed
r n p 0
Printer closed
RS-232 and
Printer do not
transmit
RS-232 and
Printer do not
transmit
RS-232 and Printer
do not transmit.
Totalized values do
not clear off
When weight is stable,
RS-232 transmits
automatically
(when re-zeroed,
RS-232 transmits next
time after stable.)
r n p 1
Printer closed
RS-232 and
Printer do not
transmit
RS-232 and
Printer do not
transmit
RS-232 and Printer
do not transmit.
Totalized values do
not clear off
RS-232
continuously transmits
r n p 2
Printer closed
RS-232
transmits
Printer does not
transmit
RS-232
transmits
Printer does not
transmit
RS-232 transmits
Printer does not
transmit
Totalized values do
not clear off
RS-232
totalizes and transmits
RS-232
transmits when
weight changes
by over 10d
RS-232
transmits when
weight changes
by over 10d
RS-232 prints TOTAL
and clears totalized
values
r n p 3
Printer
totalizes and transmits
Printer
transmits when
weight changes
by over 10d
Printer
transmits when
weight changes
by over 10d
Printer prints TOTAL
and clears totalized
values
RS-232
totalizes and transmits
RS-232
transmits when
weight changes
by over 10d
RS-232
transmits when
weight changes
by over 10d
RS-232 prints TOTAL
and clears totalized
values
r n p 4
Printer
totalizes and transmits
Printer
transmits when
weight changes
by over 10d
Printer
transmits when
weight changes
by over 10d
Printer prints TOTAL
and clears totalized
values
When weight is stable,
RS-232 totalizes and
transmits automatically
(when re-zeroed,
RS-232 transmits next
time after stable and.
weight changes by
over +10d)
RS-232 does
not transmit
RS-232 does
not transmit
RS-232 prints TOTAL
and clears totalized
values
r n p 5
When weight is stable,
Printer totalizes and
transmits automatically
(when re-zeroed,
Printer transmits next
time after stable and.
weight changes by
over +10d)
Printer does not
transmit
Printer does not
transmit
Printer prints TOTAL
and clears totalized
values


FB530/FB630 ZSME300000159

11
EXCELL PRECISION CO., LTD.


RS-232
totalizes and
transmits
RS-232
transmits when
weight changes
by over 10d
RS-232
transmits when
weight changes
by over 10d
Printer prints TOTAL
and clears totalized
values
r n p 6
Printer
totalizes and
transmits
Printer
transmits when
weight changes
by over 10d
Printer
transmits when
weight changes
by over 10d
Printer prints TOTAL
and clears totalized
values
RS-232
totalizes and
transmits
RS-232
transmits when
weight changes
by over 10d
RS-232
transmits when
weight changes
by over 10d
Printer prints TOTAL
and clears totalized
values
r n p 7
Printer
totalizes and
transmits
Printer
transmits when
weight changes
by over 10d
Printer
transmits when
weight changes
by over 10d
Printer prints TOTAL
and clears totalized
values
After RS-232 is
stable , press
key to transmit
RS-232 does
not transmit
RS-232
transmits when
weight changes
by over 10d
r n p 8
Printer closed
Printer does not
transmit
Printer does not
transmit
RS-232 and Printer do
not transmit.
Totalized values do not
clear off

Note: press and keys respectively to print labels of different forms.


FB530/FB630 ZSME300000159

12
EXCELL PRECISION CO., LTD.
Pcs
.
. .
. . .
. . . .
2-3 Counting Function
(1). Sampling
O Press key to select sample quantity from 10,20,50,100 and the display shows
, , , accordingly.

O Select sample quantity and then place samples on the platter, and then press key,
the display shows



.
After stable, the indicator enters into counting mode and the display shows sample
quantity.

Insufficient Sample ( ) Sample weight is less than 20 divisions.

Insufficient Unit Weight ( ) Unit weight is less than 0.2 division.

_ When sampling, the above two symbols indications are on. Under such conditions, the
indicator can still work, but may result in lower count accuracy.
_ When using 2-segment weighing mode, the above two symbol indications change to
Range 2 and Range 1 and the two symbol indications are off.


(2). Check Weighing
Refer to the operation of check weighing in weighing function on page 7 ~ 8.


(3). Totalizing
Refer to the operation of totalizing in weighing function on page 9.






















FB530/FB630 ZSME300000159

13
EXCELL PRECISION CO., LTD.
Chapter 3 General Function Setting
Switch on the indicator. While the indicator is counting down to zero, press and hold key
until the display shows the software program version number.
Release the key, the indicator enters into the configuration setting mode and is
showed on the display.

































Internal calibration (Reserved)
Internal calibration (Reserved)
Internal calibration (Reserved)
Internal calibration (Reserved)
Check weighing configuration
RS-232 interface (option) or Mini
Printer output setting
Exit setting mode
Internal calibration (Reserved)
Weight hold mode setting
Internal calibration (Reserved)
G value Calibration







Press key
Press key



Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key


FB530/FB630 ZSME300000159

14
EXCELL PRECISION CO., LTD.
Press key
Press key
Press key
Check weighing configuration
F8 (Hold) affects accessing to F4. If F8 is set, accessing to F4 is denied.
Press or key to select F4 function the display shows





Preset LO value
(LO value > 10d)
Press and
key to set LO value
E.g. LO value = 2 kg



Preset HI value
(HI value LO value)
Press and
key to set HI value
E.g. LO value = 2.5 kg

Preset Beeper value
Press and
key to set HI value
E.g. Beeper value = 22







.
kg


.
kg

Press key for 5 times
to clear HI, OK, LO values
Press key



.
kg

key = Increase the flash value by one (from 0 to 9)

key = Confirmation key
.


kg


A B
A 0 = After stable, the beeper beeps and the
indications are on
1 = After stable, the beeper beeps; whether
stable or not, the indications are on.
2 = whether stable or not, the beeper beeps
and the indications are on.
B 0 = No beep
1 = OK (when the weight is between Low limit
& High limit.), the beeper beeps.
2 = When the weight is under or equal to Low
limit (must be over 10d) & over or equal
to High limit, the beeper beeps.

LCD indication description:

=======
10d Low limit value High limit value

.
kg



kg



kg



Press key


FB530/FB630 ZSME300000159

15
EXCELL PRECISION CO., LTD.
RS-232 Interface (option) and Mini Printer Output Setting
J1 and J3 on the RS-232 interface are short, when the RS-232 interface is connected to a
computer.
Mini Printer interface is set as 9 600, N 8 1, including the date and time setting.
You are welcome to check with your local supplier to get a soft copy of EXCELL's
Printing Title Editing Program (a Windows-based application software)
Press or key to select F5 function the display shows



Press key
The display shows the default
Value of transmission mode
Press key
Select transmission mode

Press key
The display shows the default
value of RS-232 baud rate



Press key
Select RS-232 baud rate
(1 200, 2 400,4 800,9 600)



Press key

Next Page














key = Increase the flash value by one (from 0 to
9) or selecting baud rate from 1 200,
2 400,4 800,9 600
key =Confirmation key





No transmission (none)
Stable transmission (RS-232)
Continuous transmission (RS-232)
Press key to transmit (simple mode)
(RS-232, Mini Printer)
Press key to transmit (Complete
mode) (RS-232, Mini Printer)
Stable transmission (totalizing mode).
The format is as same as
(RS-232, Mini Printer)
Date and time printing mode
The format is as same as
(RS-232, Mini Printer)

Date and time printing mode
The format is as same as
(RS-232, Mini Printer)
After stable, press key to transmit
The format is as same as
and . (RS-232)





(from 0 ~ 8 )


FB530/FB630 ZSME300000159

16
EXCELL PRECISION CO., LTD.
Press key
Press key
Connect Mini Printer before continue
Last Page
Press key
to select printing language



Press key



























^ ^ ^ Refer to Pages 18~ 23 for details of DATA FORMAT ^ ^ ^
















Mini Printer Printing Language





Reserved




English




Traditional Chinese




Reserved

Default setting: Reserved












Date Printing Order Setting



YY MM DD


MM DD YY


DD MM YY


Default setting: YY MM DD








Press key
to select printing
date order
Press key
Press key
Press key


Input YY MM DD
Input HH MM DD


FB530/FB630 ZSME300000159

17
EXCELL PRECISION CO., LTD.
_ RS-232 Interface Format

I . Mode : UART Signal of EIA-RS0232 C
II . Format :
1. Baud rate : 1 200, 2 400, 4 800, 9 600
2. Data bits : 8 bits
3. Parity bit : None
4. Stop bits : 1 bit
5. Code : ASCII (Exchange code of American standard)





Start bit Data bits Stop bit

_ RS-232 Data Format
Stable transmission (

),Continuous transmission (

),
Press key to transmit ( )
(1) Weight unit is g
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 g

HEAD , HEAD , DATA UNIT CR LF
(2) Weight unit is kg or lb
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
kg/lb

HEAD , HEAD , DATA UNIT CR LF
(3) Weight unit is viss
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 viss

HEAD , HEAD , DATA UNIT CR LF

HEAD1 ( 2 BYTES ) HEAD2 ( 2 BYTES )
OL - Overload , Under load
ST - Display is Stable NT - NET Mode
US - Display is Unstable GS - GROSS Mode

DATA ( 7 or 8 BYTE )

2D ( HEX ) = ( MINUS )
2B ( HEX ) = +
2E ( HEX ) = . ( DECIMAL POINT )

UNIT ( 2 or 4 BYTE )

kg = 6B ( HEX ) ; 67 ( HEX )
lb = 6C ( HEX ) ; 62 ( HEX )
viss = 76 ( HEX ) ; 69 ( HEX ) ; 73 ( HEX ) ; 73 ( HEX )



FB530/FB630 ZSME300000159

18
EXCELL PRECISION CO., LTD.
Transmission example:
Data format for RS-232 continuous transmission are as below:

1. The gross weight (+0.876 kg) shows as below, after stable: (no tare or under pretare mode)
S T , G S , + 0 0 0 . 8 7 6 k g 0D 0A

HEAD , HEAD , DATA UNIT C LF
2. The net weight (-1.568 lb) shows as below without weight stability: (no tare or under pretare mode)
U S , N T , - 0 0 1 . 5 6 8 l b 0D 0A


HEAD , HEAD , DATA UNIT C LF
3. The net weight (+1.245 viss) shows as below, after stable: (no tare or under pretare mode)
S T , N T , + 0 0 1 . 2 4 5 v i s s 0D 0A


HEAD , HEAD , DATA UNIT C LF

Press key to transmit (simple mode)

English

S/N WT/UNIT ( kg / lb )

- - - - - - - - - - - - - -

0001 1.0000 Press or key
0002 1.0000 Press or key
0003 1.0000 Press or key
0004 1.0000 Press or key
0005 1.0000 Press or key
- - - - - - - - - - - - - -
0005 5.0000 Press twice to print TOTAL

_ Besides English, the model is able to choose Traditional Chinese as printing
form.







FB530/FB630 ZSME300000159

19
EXCELL PRECISION CO., LTD.

Stable Transmission (totalizing mode)

English

S/N WT/UNIT ( kg / lb )

- - - - - - - - - - - - - -

0001 1.0000 The indicator is stable

0002 1.0000 The indicator is stable

0003 1.0000 The indicator is stable

0004 1.0000 The indicator is stable

0005 1.0000 The indicator is stable

- - - - - - - - - - - - - -

0005 5.0000 Press twice to print TOTAL


_ Besides English, the model is able to choose Traditional Chinese as printing
form.





FB530/FB630 ZSME300000159

20
EXCELL PRECISION CO., LTD.
Press key to transmit (complete mode)

English

4-key serial 15 or 12-key serial
Press or key Press or key





Press or key
Press or key




Press or key

Press or key



Press twice to print
TOTAL



Press twice to print
TOTAL




_ G = GROSS T = TARE PT = PRE-TARE N = NET

_ Besides English, the model is able to choose Traditional Chinese as printing
form.







TICKET NO .0001
G 1.000kg
T 0.000kg
PT 0.000kg
N 1.000kg

(3 blank lines)


TICKET NO .0002
G 1.000kg
T 0.000kg
PT 0.000kg
N 1.000kg

(3 blank lines)


TICKET NO .0003
G 1.000kg
T 0.000kg
PT 0.000kg
N 1.000kg

(3 blank lines)



TOTAL NUMBER
OF TICKETS 0003
TOTAL
NET 3.000kg

(3 blank lines)

TICKET NO .0001
G 1.000kg
T 0.000kg
N 1.000kg

(3 blank lines)


TICKET NO .0002
G 1.000kg
T 0.000kg
N 1.000kg

(3 blank lines)


TICKET NO .0003
G 1.000kg
T 0.000kg
N 1.000kg

(3 blank lines)


TOTAL NUMBER
OF TICKETS 0003
TOTAL
NET 3.000kg

(3 blank lines)


FB530/FB630 ZSME300000159

21
EXCELL PRECISION CO., LTD.
RTC setting , the form is the same with
Press key to transmit (simple mode) (The date and time will not be
transmit without mini printer.)

English

DATE:2008/02/25
TIME : 14:30:21
S/N WT/UNIT ( kg / lb )

- - - - - - - - - - - - - -

0001 1.0000 Press or key

0002 1.0000 Press or key

0003 1.0000 Press or key

0004 1.0000 Press or key

0005 1.0000 Press or key

- - - - - - - - - - - - - -

0005 5.0000 Press twice to print TOTAL

_ Besides English, the model is able to choose Traditional Chinese as printing
form.
































FB530/FB630 ZSME300000159

22
EXCELL PRECISION CO., LTD.
DATE: 2008 / 02 / 25
TIME: 14 : 30 : 00
TICKET NO .0001
G 1.000kg
T 0.000kg
PT 0.000kg
N 1.000kg

(3 blank lines)


DATE: 2008 / 02 / 25
TIME: 14 : 30 : 00
TICKET NO .0002
G 1.000kg
T 0.000kg
PT 0.000kg
N 1.000kg

(3 blank lines)


DATE: 2008 / 02 / 25
TIME: 14 : 30 : 00
TICKET NO .0003
G 1.000kg
T 0.000kg
PT 0.000kg
N 1.000kg

(3 blank lines)



DATE: 2008 / 02 / 25
TIME: 14 : 30 : 00
TOTAL NUMBER
OF TICKETS 0003
TOTAL
NET 3.000kg

(3 blank lines)

RTC setting , the form is the same with
Press key to transmit (complete mode) (The date and time will not
be transmit without mini printer.)

English

4-key serial 15 or 12-key serial
Press or key Press or key










Press or key Press or key







Press or key
Press or key







Press twice to print
TOTAL
Press twice to print
TOTAL



_ Besides English, the model is able to choose Traditional Chinese as printing
form.

DATE: 2008 / 02 / 25
TIME: 14 : 30 : 00
TICKET NO .0001
G 1.000kg
T 0.000kg
N 1.000kg

(3 blank lines)


DATE: 2008 / 02 / 25
TIME: 14 : 30 : 20
TICKET NO .0002
G 1.000kg
T 0.000kg
N 1.000kg

(3 blank lines)


DATE: 2008 / 02 / 25
TIME: 14 : 30 : 40
TICKET NO .0003
G 1.000kg
T 0.000kg
N 1.000kg

(3 blank lines)


DATE: 2008 / 02 / 25
TIME: 14 : 31 : 10
TOTAL NUMBER
OF TICKETS 0003
TOTAL
NET 3.000kg

(3 blank lines)



FB530/FB630 ZSME300000159

23
EXCELL PRECISION CO., LTD.
RS232 and mini printer data transmission format in HOLD condition
Please set in .
When



is set as or

, 1.000kg models format is as follows.
The format is as follows for 1.000kg model.
1 . 0 0 0 k g 0D 0A




PN (part No. )
SN (Serial No.)
Setting Methods

Press and hold key for two seconds to enter in weighing mode.


About one
second

6


Press and key to input
12 sets of Part number.


About one
second

6


Press and key to input
12 sets of Serial number.



Remarks
1. PN and SN values will come back to zero when power off.
2. The type of mini printer is different for different languages.
Press key once, SN value will
increase one digit.
Press key once,
PN value is fixed.


FB530/FB630 ZSME300000159

24
EXCELL PRECISION CO., LTD.
_ Self-test Function of Printer (optional)
Press and hold key to automatically print self-test data.
------------
VERSION 10004010 Program version
DATE 2000/01/04 Printer date
TIME 200650 Printer time
MODE TAIWAN Printer language
MEMORY TEST OK Printer status

The test of Printer
1. Press and hold key to enter into.


Default20

2. Press or key to adjust the number.
3. Press key to print.
4. Input the proper number to adjust the distance.







(large distance, adjust high)







(goodstandard)






(short distance, adjust low)

5. Press key to power on.










FB530/FB630 ZSME300000159

25
EXCELL PRECISION CO., LTD.
Exit Setting Mode
Press or key to select F6 function the display shows



Press key








































Counting down to
zero and exit setting
mode


FB530/FB630 ZSME300000159

26
EXCELL PRECISION CO., LTD.
Weight Hold Mode setting
_ Under hold mode, press key to print the hold value showed.
(Select proper baud rate according to receiver and F5 transmission mode does not affect)
(Refer to F5 for details of transmission rate)
Please make sure MINI JUMPER of SWA1 is connected to ADJ on PC board before setting.
Please make sure MINI JUMPER of SWA1 is connected to LOCK on PC board after setting.
Press or key to select F8 function the display shows


















































Press key in order and the display
shows accordingly
~
Select required hold mode and then press
key to finish setting.
Press key
Press key
Press key
Press key
Press key
Press key


FB530/FB630 ZSME300000159

27
EXCELL PRECISION CO., LTD.
Animal scale hold mode setting




Choose hold 4
Press key



























Setting Error Range
Press and keys to set error range
from 1% ~ 100%
Default setting: 10%
%


Average Trade Count Setting
Press and keys to set from 1.2.4.
8.16.32.64.
Default setting: 8


%







Press key
Press key

Press key
Press key
Press key
Hold function Disable
When the weight keeps changing, the indicator will automatically hold
and display the largest value.
Press any key except key to clear the hold value.
When the indicator becomes stable, the display shows and holds the
weight value, which can not be changed.
Press any key except key to clear the hold value.
When the indicator becomes stable, the display shows and holds the
weight value, which can not be changed.
When the indicator is re-zeroed (weight less than 10d), the hold value is
automatically cleared.


Animal scale. When the animal is on the platter, the display shows the
weight value, which can not be changed.
When the animal leaves the platter (weight less than 10d), the indicator is
re-zeroed automatically.


FB530/FB630 ZSME300000159

28
EXCELL PRECISION CO., LTD.
G value Calibration
Press key or key to select F10 function. The display shows

.
You can input at most 9 sets of G values data when SWA1 is set in LOCK. The historic
data can be found out and not to be revised.
The G value data is fixed in XX set (only one set) and all the historic data is cleared when
SWA1 is set in ADJ.
After do weight calibration, G value will reserve the last data and other historic data will be
cleared.



























.





















.





















.















.













.















.









.














Press key
Press key
After about 1 second
The screen displays revised times at present and then displays local G value after about 1 second.
After about 1 second
The screen displays last revised times and then displays local G value after about 1 second.
The screen displays the first two revised times and then displays local G value after about 1 second.
After about 1 second
01 Fix to save ADJ condition, input local G value in F9.
Press key to
enter into G value
revised mode.
After about 1 second
After about 1 second
00 Fix to save G value in manufacture site.

Input local G value
Press and key to input the
number. Press key to Shift the flashing
digit one space to right.
Press key to save
the data and then complete
the revise.
Press key
Press key
Press key
Press key
Press key
Press key


FB530/FB630 ZSME300000159

29
EXCELL PRECISION CO., LTD.
Load Cell Pin Description (input signal)























1. EXC+
2. EXC-
3. SIG+
4. SIG-
5. Shield
4-wire or 5-wire Load Cell (L/C)
FB model



JP 21,JP 22 Short

PCB

L/C

(E+) connect to EXC+

(E -) connect to EXC -

(S+) connect to SIG+

(S -) connect to SIG -

(FG) connect to Shield

Note: JP 21 and JP 22 are on the PCB in FB Model.


FB530/FB630 ZSME300000159

30
EXCELL PRECISION CO., LTD.
Option Function Description
RS-232 output description (for FB model)
1. RS-232 OPTION Card : AD05135 = > 4 PIN connect to CN8 of main board
2. Please refer to F5 function settings for transmission mode, baud rate setting and data
format.
3. RS-232 (DB 25PIN) Pin Description

J1, J3 SHORT; J2, J4 OPEN (default setting)
Pin 2 RXD
Pin 3 TXD
Pin 7 GND
Other pins are disabled.

J2, J4 SHORT; J1, J3 OPEN
Pin 2 TXD
Pin 3 RXD
Pin 7 GND
Other pins are disabled.





Error Messages
OL The scale is over full scale +9d.
E1 Zero value after power on is over 10% FS when JP5 on the PCB in FB model is short.
E2 Zero value after power on is less than10% FS when JP5 on the PCB in FB model is short.
E4 Re-zero is unstable. When it is over 10 seconds, press 0 to exit E4.
E6 Zero value is over 550 000 when calibrating.
E7 Zero value is less than 150 000 when calibrating.
E10 LEVEL Switch Function: JP2 on the PCB in FB model is open, connect the signal to
CN1. When CN1 is open, the display will disappear and then show E10. When CN1 is short, the
scale can be weighed in general condition. If not using LEVEL Switch Function, please JP2 is
set to be short.











FB530/FB630 ZSME300000159

31
EXCELL PRECISION CO., LTD.
Appendix 1 ASCII Code Table
Symbol ASCII Code Symbol ASCII Code Symbol ASCII Code
A 41H a 61H 0 30H
B 42H b 62H 1 31H
C 43H c 63H 2 32H
D 44H d 64H 3 33H
E 45H e 65H 4 34H
F 46H f 66H 5 35H
G 47H g 67H 6 36H
H 48H h 68H 7 37H
I 49H i 69H 8 38H
J 4AH j 6AH 9 39H
K 4BH k 6BH 0DH
L 4CH l 6CH
M 4DH m 6DH
N 4EH n 6EH
O 4FH o 6FH
P 50H p 70H
Q 51H q 71H
R 52H r 72H
S 53H s 73H
T 54H t 74H
U 55H u 75H
V 56H v 76H
W 57H w 77H
X 58H x 78H
Y 59H y 79H
Z 5AH z 7AH







FB530/FB630 ZSME300000159

32
EXCELL PRECISION CO., LTD.
Appendix 2 7-Segment Display Characters
Number Display Letter Display Letter Display
0

A

N

1

B

O

2

C

P

3

D

Q

4

E

R

5

F

S

6

G

T

7

H

U

8

I

V

9

J

W

K

X

L


Y




M

Z






FB530/FB630 ZSME300000159

33
EXCELL PRECISION CO., LTD.
Appendix 3 Printer Installation
A. Roll paper installation and problems solution
1. Installation roll paper:
Use designated roll paper with a width 44.5 0.5 mm and internal diameter 50 mm.
Fix the roll paper into the paper entrance of the Printer.
Cut the edge of the paper leveling and then install the paper (refer to V of picture A).
And then use Feed key to complete installation (make sure the paper is parallel with the
printing location. Avoid operating as X of picture A )
The paper should not be folded or broken.

2. Uninstall roll paper:
Cut up the paper at the entrance of Printer, and then
pull out the paper from the exit of Printer.

3. Paper jam solutions procedures:
Uninstall the paper first.
Use a nipper or others to clear remain wastepaper.


B. Ribbon installation
Use designated ribbon. (ERC-05)

Uninstall the roll paper before install the ribbon. (Picture B)

Turn and tighten the ribbon before installation.

Sway the ribbon to proper location according to Picture C.
If the ribbon loosens during installation, retighten
it according to Picture D.

To uninstall the ribbon, press gently the location in Picture E,
and then take it out with proper adjustment.

The ribbon of the model received may deviate its location during
its transportation, and this may lead to the breakdown of the Printer.
To solve this problem, reinstall the ribbon according to the
above procedures.






Picture E
Picture D
Picture C
Picture B
Picture A


FB530/FB630 ZSME300000159

34
EXCELL PRECISION CO., LTD.
Appendix 4 Load Hook Installation
Please install the load hook (only for FB-630) according to correct order as follows.