Power factor correction and harmonic filtering

Automatic power factor regulators

Automatic power factor reguladors


computer Plus-T
Intelligent regulator R1-5

computer MAX
Automatic power factor regulator R1-7

computer Smart
Automatic power factor regulator R1-9

computer plus-TF
Fast power factor regulator (Static capacitor banks) R1-11

computer MAX-f
Fast power factor regulator (Static capacitor banks) R1-13

computer Smart fast


Automatic power factor regulator (Static capacitor banks) R1-15

DIR2
1-step power factor relay. DIN rail R1-17

R1-2

Automatic power factor regulators

Automatic power factor regulators


The use of automatic power factor regulators is required for power factor compensation purposes in installations with variable loads. CIRCUTOR's computer regulators can be used to monitor existing load curves accurately, whereby the cos is guaranteed to reach the programmed values. The whole range of computer regulators is based on CIRCUTOR's FCP system (Fast Computerized Program), offering a set of unique performance features:
}} Minimisation of the number of switching operations, increasing the working life of the components in the capacitor bank. }} Increase in the unit's response time,

In order to compensate installations with quick load variations, CIRCUTOR's fast series computers must be used, since they are capable of compensating the reactive consumption in milliseconds (ms). In unbalanced systems, if you wish to install a conventional regulator that will measure a single phase, you run the risk of insufficient or excessive com pensations. CIRCUTOR has designed the computer plus series to compensate unbalanced installations. Computer plus is available in the plus-T version (contactor switching) and PlusTF version (thyristor switching), which are capable of compensating the total reactive consumption in real time and phase-by-phase. Computer Plus is an innovative product that offers a wide range of new characteristics, three-phase measurements, phase-by-phase compensation, built-in power analyzer, test function, protection against harmonics, leakage, control, communications, etc. This catalogue includes additional information about our new product. The following example shows how the unbalance between phases can be calculated in a percentage and how to determine the need to perform a compensation process with a three-phase measurement using the Plus system.

R.1
Installation examples: Power Factor L1: 80 kvar Power Factor L2: 90 kvar Power Factor L3: 110 kvar Mean value: L1+L2+L3 / 3 = 93.33 kvar % unbalance L1= (L1-mean value / mean value) x100= 14.28 % % unbalance L2= (L2-mean value / mean value) x100= 3.33 % % unbalance L3= (L3-mean value / mean value) x100= 17.86 %

thus achieving greater energy savings. Anti-oscillation system, preventing unwanted capacitor connections and disconnections. Optimum regulation, thanks to the accurate information about the status of network parameters and the anti-oscillation system, guaranteeing that the installation load curve can be monitored accurately and the objec tive cos can be attained. Measurement and compensation CIRCUTOR's vast range of regulators has been designed to cover the compensation requirements in each different type of installation.

The threshold will be used to choose whether our capacitor bank will have a three or single-phase measurement, within a 12% unbalance in one of the phases. The previous example shows that L1 and L3 are above 12% of the unbalance, so the use of computer Plus is required.

R1-3

Automatic power factor regulators

Product selection table


Equipment computer plus-T Types of loads Types of installation Minimum response time Page

slow

unbalanced (Three-phase measurement regulator)

4s

computer MAX

slow

balanced (Single-phase measurement regulator)

4s

Computer Smart

slow

balanced (Single-phase measurement regulator)

4s

computer plus-TF

fast

unbalanced (Three-phase measurement regulator)

40 ms

11

computer MAX-f

fast

balanced (Single-phase measurement regulator)

40 ms

13

Computer Smart-f

fast

balanced (Single-phase measurement regulator)

40 ms

15

slow

control of a single step

1s

17

R1-4

DIR

Automatic power factor regulators

computer Plus-T
Intelligent regulator
Description
Intelligent state-of-the-art regulators, capable of measuring the Three-phase networks and compensating the total reactive consumption accurately. The Plus-T power factor regulators have been designed with CIRCUTOR's measurement system technology, effectively creating a compensation + measurement unit. As a power analyzer, it displays any electrical parameter of the network in real time and records it in its internal memory, with maximum and minimum values, date and hour. The user can benefit from the following advan tages as a result of the many new features: }} The measurement of the three phases guarantees the real compensation of the installation. }} Protection against harmonics, with an anti-resonance system. }} Easy installation, fully self-programmable, operation start-up by pressing just one key }} New regulation program that enables the use of any type of sequence }} Greater continuity of the service, control and display of leakages, with step-by-step earth leakage protection }} Internal temperature sensor, for the protection against excessive temperatures, with alarm and/or disconnection system }} Test function to check the whole unit by pressing just one key }} The communications system can be used by the user to display the distance of unit parameters and the network for the preventive super vision and maintenance tasks.

Features
Features Type of measurement Power analyzer Alarms Test function Anti-resonance system Plug and play function (self-programmable) Step-by-step earth leakage protection RS-485 Communications (modbus protocol) Measurement of current in capacitors Measurement of temperature Power supply circuit Voltage Consumption Frequency Measurement circuit Nominal voltage Frequency Nominal current Overload (permanent) Voltage class Current class Power class Relays Maximum switching voltage Maximum switching current Ambient conditions Operating temperature Build features Type of box Fitted unit, protection degree (frontal) Fitted unit, protection degree (rear) Dimensions Safety V0 self-extinguishing plastic IP 51 IP 21 144 x 144 x 90 mm CAT III 0 ... 55 C 250 V ac 3A 110 ... 300 V 45 ... 65 Hz 1 to 5 A max. 15 % 0,5 0,5 0,5
ph-n

Three-phase Measurement: cos , PF, U, I, In, THD(I), THD(U), kVA, kW, kvarC, kvarL, kwh, kvarh, Hz, temperature. Max and min records, with date and hour of the electrical parameters. Temperature, voltage, current, THD(I), THD(U), kvar, cos , capacity loss. Loss of capacity, resonance, cos Built-in Built-in CDI Version CDI Version CDI Version Built-in 110 ... 480 V ac 6 VA 45 ... 65 Hz , 190 ... 520 V

ph-ph

Application
Computer Plus-T regulators are ideal to compensate modern installations that often have unbalanced loads. Its three-phase measurement system and power analyzer function, safety, monitoring and control system make it the ideal candidate to compensate installations where the precision and continuity of the service are fundamental factors.

R1-5

Automatic power factor regulators

computer Plus-T
Intelligent regulator

Dimensions

144

93 84

References
No. of steps 8 14 8 14 Three-phase measurement Yes Yes Yes Yes Alarms Yes Yes Yes Yes Communications, Earth Leakage, Icapacitors No No Yes Yes Type computer Plus-T8 computer Plus-T14 computer Plus-T8 CDI computer Plus-T14 CDI Code R12011 R12211 R12111 R12212

Connections
Current measurement in the capacitor bank

Secondary Current transformers inputs Communications


S1 S2 S1 S2 S1 S2

144
Earth leakage
Rels COM C1 C2 C3 C4 C5 C6 C7 C8 C9 C1 0 C 11 C1 2 C 13 C1 4 Alarm VL1 VL2 VL3 N S1 S2 S1 S2 S1 S2 Power supply L1 L2 L3 N

R1-6

Automatic power factor regulators

computer MAX
Automatic power factor regulator

Description
The state-of-the-art regulators of the MAX Series have been designed to offer simple and efficient regulation features. The whole range of computer regulators is based on CIRCUTOR's FCP system (Fast Computerized Program), offering a set of unique performance features. Its main features are as follows: }} Shows by display: cos , voltage, current, THD(I) and, besides, records in memory maximum values for voltage and current provides the phase selection function, that allows the user choosing the power line phase where the measuring current transformer (C.T.) has been placed in allows viewing in display the variation of cos , line current and THD(I), when manually connecting or disconnecting capacitor steps. }} Indication by display or through relay output of following alarm conditions: Compensation failure, Over-compensation, Over-voltage, Over-current, C.T. not connected or open, Line current below measurable value.

Features
computer MAX 6 Voltage circuit Power supply Tolerance Consumption Frequency Measurement circuit measuring voltage Nominal current (In ) Output relay Maximum voltage Nominal current Electrical endurance Alarm relay Relay Alarms Build features Operating temperature Assembly Dimensions Connection Degree of protection Performance Measure electric parameters phase selection function Voltage, current, THD(I), and maximum values of U and I Selection of the power line phase where the C.T. is placed FCP / 4 quadrants 1.1.1.1 / 1.2.2.2 / 1.2.4.4 / 1.2.4.8 / 1.1.2.2 Cos Correction Test & Harmonic Resonance Test 4 ... 999 s 5 Tr -10 ... +50 C Panel 144 x 144 mm Connection strip IP 52 (front) / IP 31 (rear) Last relay configurable as alarm output Compensation failure, Over-compensation, Overvoltage, Over-current, C.T. not connected or open, Line current below measurable value 6 250 Vac 4A 5 * 104 / 5 * 106 opetarions 230, 400, 480 Vac (accor. to type) Current transformer In / 5 A 12 4 VA 45 ... 65 Hz 230, 400, 480 Vac (accor. to type) -10... +15 % 64 VA computer MAX 12

Application
The computer MAX regulator is ideal to compensate unbalanced installations where the ease or programming, robustness and accuracy are vital requirements. Its programming system is simple and intuitive, making it very easy for the user to install and maintain it.

Integrated control system Connection programs Test Function Tr Connection delay Ts Safety delay Standards

IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11

R1-7

Automatic power factor regulators

computer MAX

Dimensions

Automatic power factor regulator

References
Power supply voltage 400 V a.c. 400 V a.c. 110 V a.c. 110 V a.c. 230 V a.c. 230 V a.c. 480 V a.c. 480 V a.c. No. of steps 6 12 6 12 6 12 6 12 Size 144 x 144 144 x 144 144 x 144 144 x 144 144 x 144 144 x 144 144 x 144 144 x 144 Type computer Max 6 computer Max 12 computer Max 6 computer Max 12 computer Max 6 computer Max 12 computer Max 6 computer Max 12 Code R10831 R10842 R10831001 R10842001 R10831002 R10842002 R10831004 R10842004

Connections

computer 6m

computer 12m

Power supply

Power supply

R1-8

Automatic power factor regulators

computer Smart
Automatic power factor regulator

Description
Computer Smart is a leading edge power factor regulator, providing in a single device the functions of power factor correction, power analyzer and leakage current protection. The regulator is equipped with the latest world technology, which allows CIRCUTOR offering to the market a simple regulator, but capable of performing many advanced functions as: Capacitors status monitoring, earth leakage current monitoring, capacitors failure prevention, overheating detection, etc.. All these functions contribute to a longer life and a better power quality, and avoid intempestive supply interruptions. Because all the above features, the Smart becomes one of the PF regulators with the best performance, while still offering users an easy use and intuitive programming.

Features
Supply circuit Power supply voltage Tolerance Consumptions Frequency Measurement circuit Voltage measurement range Current measurement (In) Leakage current Leakage current range Transformers type Full scale at secondary side Measuring circuits accuracy 1% Temperature measurement 0 ... +80 C 3 C Output Contact type Poder de corte Alarms No. Alarm 14, totally configurables RS-485 Modbus 9600, 19200, 38400 Bd, configurable -20 ... +60 C Max. 95% 2000 m FCP (a programme that minimises the number of operations) Safety Insulation Degree of protection Standards IEC 62053-23 (2003-01) Ed. 1.0, IEC 61326-1, EN61010-1, UL 508 (* optional) Category III Class II EN 61010-1 IP 40 / IP 30 EN-60529 Communications Hardware Protocol Baud rate Operating conditions Temperature Relative humidity Maximum altitude Control system Change over contact Vmax 250 V a.c., 4 A a.c., AC1 cos : 2 % 1 digit Iprim: 10 mA ... 1 A a.c. WGC (*) Isec = 20 mA 480, 400, 230, 110 V a.c. depending on model By means of a current transformer In /5 480, 400, 230, 110 V a.c. depending on model +15 % -10 % 8,2 VA (0 relays connected) 9,3 VA (6 relays connected) 11 VA (12 relay connected) 45 ... 65 Hz

Aplication
Computer Smart offers a complete system for facilities that requires PF correction, security, measure, communications and monitoring. Its simple and intuitive programming system enable de user the installation and maintenance.

R1-9

Automatic power factor regulators

computer Smart

Dimensions

Automatic power factor regulator

144

63

References
Power supply voltage 400 V a.c. 400 V a.c. 110 V a.c. 110 V a.c. 230 V a.c. 230 V a.c. 480 V a.c. 480 V a.c. No. of steps 6 12 6 12 6 12 6 12 Alarm Yes Yes Yes Yes Yes Yes Yes Yes Size 144 x 144 144 x 144 144 x 144 144 x 144 144 x 144 144 x 144 144 x 144 144 x 144 Type computer Smart 6 computer Smart 12 computer Smart 6 computer Smart 12 computer Smart 6 computer Smart 12 computer Smart 6 computer Smart 12 Code R13831 R13842 R13831001 R13842001 R13831002 R13842002 R13831004 R13842004

Connections
computer Smart 6 computer Smart 12

R1-10

144

Automatic power factor regulators

computer plus-TF
Fast power factor regulator (Static capacitor banks)

Description
State-of-the-art intelligent regulators that are capable of measuring the three-phase networks and compensating the reactive consumption of each phase in real time. In addition, they correct the total zero reactive energy and balance the active power in each phase. The Plus-TF power factor regulators have been designed with CIRCUTOR's measurement system technology, effectively creating a compensation + measurement unit. As a power quality analyzer, it displays any electrical parameter of the network in real time and records it in its internal memory, with maximum and minimum values, date and hour. The user can benefit from the following ad vantages as a result of the many new features: }} The measurement of the three phases guarantees the real compensation of the installation. }} Phase-by-phase compensation and in real time }} Protection against harmonics, with antiresonance system }} Easy to install, fully self-programmable, starts operating by pressing just one key }} New regulation program that enables the use of any type of sequence }} Greater continuity of the service, control and display of leakages, with step-bystep earth leakage protection }} Internal temperature sensor, for the protection against excessive temperatures, with alarm and/or disconnection system }} Test function to check the whole unit by pressing just one key. }} The communications system can be used by the user to display the distance of unit parameters and the network for the preventive supervision and maintenance tasks. balances between phases, such as welding units, cranes, lifts and lifting units, smelters, hospitals, automotive industry or any other sector or unit that requires an efficient compensation of the power factor. Some of the advantages of this compensation system are as follows: }} Elimination of transients produced by the capacitor's connection. }} The lack of transients in the connection allows us to eliminate gaps, flicker and any other alteration generated by the connection's transient }} Limited switching operations, guaranteeing a longer working life for the unit }} Immediate response to the compensation request }} Lower wear of capacitors and switching elements, due to the elimination of transients and the total absence of mobile mechanical parts }} Eliminates or reduces the effects of voltage drops caused by reactive consumption peaks. Its phase-by-phase compensation functions make computer Plus-TF the most efficient regulator in the market.

Application
Computer Plus-TF regulators are ideal to compensate modern installations that often have unbalanced loads. Its three-phase measurement system, phase-by-phase compensation and power analyzer functions make it the ideal solution to compensate installations with a variation of quick loads, between 20 ms and 4 seconds, and/or large un-

R1-11

Automatic power factor regulators

Fast power factor regulator (Static capacitor banks)

computer plus-TF

Features
Features Type of measurement Type of compensation Minimum response time Power analyzer Three-phase Phase-by-phase 2 cycles (40 ms) Measurement: cos , PF, U, I, In, THD(I), THD(U), kVA, kW, kvarC, kvarL, kWh, kvarh, Hz, temperature. max. and min. records, with date and hour of the electrical parameters. Temperature, voltage, current, THD(I), THD(U), kvar, cos , loss of capacity. Loss of capacity, resonance, cos . Built-in Built-in CDI Version Built-in CDI Version Built-in 110 - 480 Vac 6 VA 45 ... 65 Hz 110 - 300 V 45 ... 65 Hz 1 to 5 A max. 15 % 0,5 0,5 0,5 0...55 C V0 self-extinguishing plastic IP 51 IP 21 144 x 144 x 90 mm CAT III , 190 - 520 V

Dimensions

144

93 84

Alarms Test function Anti-resonance system Plug and play function (self-programmable) Step-by-step earth leakage protection RS-485 Communications (modbus protocol) Measurement of current in capacitors Measurement of temperature Power supply circuit Voltage Consumption Frequency Measurement circuit Nominal voltage Frequency Nominal current Overload (permanent) Voltage class Current class Power class Ambient conditions Operating temperature Build features Type of box Fitted unit, protection degree (frontal) Fitted unit, protection degree (rear) Dimensions Safety

Connections

144

Current measurement in the capacitor bank


Secondary Current transformers inputs Communications
S1 S2 S1 S2 S1 S2

Earth leakage

Rels

COM

C1

C2

C3

C4

C5

C6

C7

C8

C9

C1 0 C 11 C1 2 C 13 C1 4 Alarm

Power supply

VL1 VL2 VL3

S1

S2

S1

S2

S1

S2

ph-n

ph-ph

L1 L2 L3 N

References
No. of steps 16 16 Three-phase measurement Yes Yes Alarms Yes Yes Communications No Yes Earth Leakage, Icapacitors No Yes Type computer Plus TF computer Plus TF CDI Code R12511 R12611

R1-12

Automatic power factor regulators

computer MAX-f
Fast power factor regulator (Static capacitor banks)
Description
The computer MAX-f series of regulators is within the fast regulator range, with a response time of 40 ms, adapted to real time compensation requirements. Main Features: }} Shows by display: cos , voltage, current, THD(I ) and, besides, records in memory maximum values for voltage and current. }} Provides the phase selection function, that allows the user choosing the power line phase where the measuring current transformer (C.T.) has been placed in allows viewing in display the variation of cos , line current and THD(I), when manually connecting or disconnecting capacitor steps. }} Indication by display or through relay output of following alarm conditions: Compensation failure, Over-compensation, Over-voltage, Over-current, C.T. not connected or open, Line current below measurable value.

Features
Voltage circuit Power supply Tolerance Consumption Frequency Measurement circuit measuring voltage Nominal current (In ) 4 VA 45 ... 65 Hz 230, 400, 480 Va.c. (accor. to type) Current transformer In / 5 A 6 250 Vac 4A 5 * 104 / 5 * 106 opetarions Last relay configurable as alarm output Compensation failure, over-compensation, over-voltage, over-current, C.T. not connected or open and line current below measurable value -10 ... +50 C Panel 144 x 144 mm Connection strip IP 52 (front) / IP 31 (rear) Voltage, current, THD(I), and maximum values of U and I Selection of the power line phase where the C.T. is placed FCP / 4 quadrants 1.1.1.1 / 1.2.2.2 / 1.2.4.4 / 1.2.4.8 / 1.1.2.2 Cos Correction Test & Harmonic Resonance Test 40 ms ... 2 s 40 ms ... 2 s 12 computer MAX 6 -10... +15 % 64 VA computer MAX 12

230, 400, 480 Va.c. (accor. to type)

Application
The computer MAX-f system has been designed to compensate installations that have a special load typology and require real time compensation, such as welding units, cranes, lifts and lifting equipment, smelters, hospitals, automotive industry or any other sector/unit that requires a real time compensation. Some of the advantages of this compensation system are as follows: }} Elimination of transients produced by the capacitor's connection. }} The lack of transients in the connection allows us to eliminate gaps, flicker and any other alteration generated by the connection's transient }} Limited switching operations, guaranteeing a longer working life for the unit }} Immediate response to the compensation request }} Lower wear of capacitors and switching elements, due to the elimination of transients and the total absence of mobile mechanical parts }} Eliminates or reduces the effects of voltage drops caused by reactive consumption peaks.

Output relay Maximum voltage Nominal current Electrical endurance Alarm relay Relay Alarms Build features Operating temperature Assembly Dimensions Connection Degree of protection Performance Measure electric parameters phase selection function Integrated control system Connection programs Test Function Tr Connection delay Ts Safety delay Standards

IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11

R1-13

Automatic power factor regulators

Computer MAX-f

Dimensions

Fast power factor regulator (Static capacitor banks)

References
Power supply voltage 400 V a.c. 400 V a.c. No. of steps 6 12 Alarm --Size 144 x 144 144 x 144 Type computer MAX 6f computer MAX 12f Code R10851 R10862

Connections

R1-14

Automatic power factor regulators

computer Smart fast


Automatic power factor regulator (Static capacitor banks)
Description
Computer smart fast is a leading edge power factor regulator, providing in a single device the functions of power factor correction, power analyzer and leakage current protection. The regulator is equipped with the latest world technology, which allows CIRCUTOR offering to the market a simple regulator, but capable of performing many advanced functions as: Capacitors status monitoring, earth leakage current monitoring, capacitors failure prevention, overheating detection, etc.. All these functions contribute to a longer life and a better power quality, and avoid intempestive supply interruptions.

Features
Supply circuit Power supply voltage Tolerance Consumptions Minimum response time Frequency Measurement circuit Voltage measurement range Current measurement (In) Leakage current Leakage current range Transformers type Full scale at secondary side Measuring circuits accuracy 1% Temperature measurement 0 ... +80 C 3 C Output Contact type Poder de corte Alarms No. Alarm Communications Hardware Protocol Baud rate Operating conditions Temperature Relative humidity Maximum altitude Control system FCP (a programme that minimises the number of operations) Safety Insulation Degree of protection Standards IEC 62053-23 (2003-01) Ed. 1.0, IEC 61326-1, EN61010-1, UL 508 (* optional) Category III Class II EN 61010-1 IP 40 / IP 30 EN-60529 -20 ... +60 C Max. 95% 2000 m RS-485 Modbus 9600, 19200, 38400 Bd, configurable 14, totally configurables Change over contact Vmax 250 V a.c., 4 A a.c., AC1 cos : 2 % 1 digit Iprim: 10 mA ... 1 A a.c. WGC (*) Isec = 20 mA 480, 400, 230, 110 V a.c. depending on model By means of a current transformer In /5 480, 400, 230, 110 V a.c. depending on model +15 % -10 % 8,2 VA (0 relays connected) 9,3 VA (6 relays connected) 11 VA (12 relay connected) 2 cycles (40 ms) 45 ... 65 Hz

Aplication
Computer Smart fast its the ideal solution to compensate installations with a variation of quick loads, between 40 ms and 4 seconds, and/or large unbalances between phases, such as welding units, cranes, lifts and lifting units, smelters, hospitals, automotive industry or any other sector or unit that requires an efficient compensation of the power factor. Some of the advantages of this compensation system are as follows: }} Elimination of transients produced by the capacitors connection. }} The lack of transients in the connection allows us to eliminate gaps, flicker and any other alteration generated by the connections transient }} Limited switching operations, guaranteeing a longer working life for the unit }} Immediate response to the compensation request }} Lower wear of capacitors and switching elements, due to the elimination of transients and the total absence of mobile mechanical parts }} Eliminates or reduces the effects of voltage drops caused by reactive consumption peaks. Its phase-by-phase compensation functions make computer Smart Fast the most efficient regulator in the market.

R1-15

Automatic power factor regulators

computer Smart fast

Dimensions

Automatic power factor regulator

144

63

References
Power supply voltage 400 V a.c. 400 V a.c. No. of steps 6 12 Alarm Yes Yes Size 144 x 144 144 x 144 Type computer Smart fast 6 computer Smart fast 12 Code R13931 R13942

Connections
computer Smart fast 6 computer Smart fast 12

R1-16

144

Automatic power factor regulators

DIR2

1-step power factor relay. DIN rail

Description
The DIR2 power factor relay is capable of acting on a circuit in accordance with the reactive inductive or capacitive current transmitted through it. The DIR2 relay measures reactive current in mA of the secondary of a .../250 mA current transformer MC1 or MC3 type. The front of the relay has a control panel that is used to adjust the reactive current where the relay will act. It has a LED that indicates the status of the relay.

Features
Voltage circuit Power supply Tolerance Consumption with all relays connected Frequency Measurement circuit Consumption Nominal current (In ) Outputs No. of outputs Maximum voltage Maximum current Build features Operating temperature Assembly Connection Degree of protection -10 ... +50 C DIN rail Terminals IP 21 1 200 V 100 mA 0.5 VA 250 mA 400 Vac 10 % 5 VA 50 ~ 50 Hz

Application
The DIR2 relay is easy to install and program, making it the best solution in the following applications: }} Individual compensation of small, medium or large power loads. }} Partial compensation in installations with automatic equipment available. }} Partial or total regulator in low-power installations.Instantaneous and total disconnection of capacitor banks when there is a high capacitive current in the network. Control of reactive currents - capacitive and inductive - triggering an alarm signal when a high current is detected.

R1-17

Automatic power factor regulators

DIR2
1-step power factor relay. DIN rail

Dimensions

References
Power supply voltage 400 Va.c. No. of steps 1 Alarm Size 35 x 85 Type DIR Code R11211

Connections

P1
L1 L2 L3 N
S1 S2

P2 S2

S1

A1

A2

DIR
0, 15 0, 5 1 2 1, 5

16

15

18

R1-18

Automatic power factor regulators

R1-19

Automatic power factor reguladors