CLIENT: CNPCI/NESCO Consortium 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 Total Flow: Operating Pressure: Operating Temperature: Vapor Density: Liquid Density: Code: ASME Stamp 1.02 Yes Yes 1.35 at at 55 Location: Service: Design Code: Vessel Size: Thickness: Vessel Type: Heads: Medium: ID. Shell: Vertical 2:1 Ellipse Hydrogen Severe Indoor Under Shelter PROCESS DATA 64L/S 1.0 40 (10 m ) MPag
o 3

UNIT:

PU & DP

DOCUMENT NO.: MIS-M-DS-04054 Company Project Number: Purchase Order Number: Supplier Project Number:

REV. A

PAGE 1 OF 2

Item Name: Item Tag Number: No Items:

FOAM PROPORTIONING UNIT V-07130 1 GENERAL

Information to be completed by: Applicable to: Proposal

Purchaser Purchase

Vender As Built

Vender if not completed by Purchaser

DESIGN CRITERIA Foam Proportioning Unit ASME Section VIII - Division 1 mm mm S/S Head: Horizontal Other Type: Lethal Wet H 2S Outdoor Cyclic mm mm Material Code: Shell: Head: Pipes: Flange: Blots: Nuts: Gaskets: Supports: Internals:

MATERIALS ASME Section II A516-60 A516-60 A106 Gr.B A105 A193 A194-2H Spirally Wound Non-asbestos Gaskets A36 A36/A516/A106

MANUFACTURE AND TEST REQUIREMENTS Manufacturing Code: Welding Code: NDE Code:
3

ASME Section VIII-Division 1 ASME Section IX ASME Section V As Per Code As Per Code As Per Code As Per Code Yes Yes No No

kg/m

Ultrasonic: Magnetic Paricle: X-Ray Inspection Length: X-Ray NDE Grade: Hydraulic Test: Painting and Packing:

kg/m3 No No MPag
o o o

Board Registration: Internal Design Pressure: Top, Mpa Bottom, Mpa Design Temp: Normal Liquid Level: Max Wind Speed: Seismic Zone: Corrosion Allowance: Shell: Insulation: Type: 3 mm

C C C

As Per Specification MIS-L-SP-03537 Corrosion Prevention: Lifting Lug: Yes Yes No No

mm 29.8 m/s hold

INTERNALS Mist Eliminator: Yes No

Heads: 3 Yes

mm

Nozzles: No

mm

Type: Vortex Breakers: Coil: Others: Yes Yes No No

Thickness:

A Rev.

June 18,05 Date

Issued For Approval Description

Fan Xixuan By

Tao Lifeng Checked

Lu Huanxuan Reviewed

Zhai Feng Approved

MIS DEVELOPMENT PROJECT


FOAM PROPORTIONING UNIT DATA SHEET
CLIENT: CNPCI/NESCO Consortium 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 NOTE: 1. All nozzle orientations to be defined later. 2. Reference PID: MIS-P-DW-01711. Applicable spec: MIS-M-SP-04004. 3. The foam concentrate shall be stored in a rubber vesicle to separate from pressure fresh water. valves and instruments, etc. 4. The mixing ratio is 94:6 between fresh water and foam concentrate in the pressure proportion mixer. 5. The foam concentrate shall be stored in a rubber vesicle to separate from pressure fresh water. 6. The foam proportion unit is one septum positive pressure proportion mixing type. 7.The vessel size and all the internals should be checked by EPC contractor. Mark N1 N21-3 N3 N41-3 MW PG1-2 Qty 1 3 1 3 1 2 Size 2" 1" 2" 2" 24" 1/2" Type RF RF RF RF RF NPTF Rating ANSI 150 ANSI 150 ANSI 150 ANSI 150 ANSI 150 ANSI 3000 Water Inlet Gas Outlet Outlet Drain Manway with Davit Pressure Gauge Type of Support: Skirt Insulation Supports: Fire Proofing Supports: Skid Mounted: Manway Davit/Hinge: Ladder: Platform: Legs Saddle Yes Yes Yes Yes Yes Yes Lugs No No No No No No NOZZLES Service ATTACHMENT Empty Weight: Operating Weight: Weight Filled With Water: Dimension: L x W x H: mm UNIT: PU & DP DOCUMENT NO.: MIS-M-DS-04054 REV. A PAGE 2 OF 2

WEIGHT AND DIMENSION By Vendor By Vendor By Vendor kg kg kg