FlexiPacket Hub

FT4282CEN02GLA0
2010 Nokia Siemens Networks
1
Contents
1 Introduction 3
1.1 FlexiPacket Hub 2200 4
1.2 FlexiPacket Hub 1200 31
1.3 A 2200/A 1200 Quality of Service (QoS) 41


FlexiPacket Hub
FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
2
FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
3
1 Introduction
The FlexiPacket Hub 2200/1200, as part of the Nokia Siemens Networks Carrier
Switches portfolio, allows a smooth integration in a Carrier Ethernet Transport
network, ensuring end to end network design, including advanced QoS,
Synchronization and OAM.
FlexiPacket Hub is the indoor unit of Nokia Siemens Networks FlexiPacket
Microwave system.
FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
4

1.1 FlexiPacket Hub 2200
A2200 system is a modular system, as depicted in Fig. 1, based on a fixed main
board with Pluggable Interface Cards (IFCs), Power supply and TDM card.
The main board is the heart of the system: it contains the main system controller and
handles the traffic management.
Up to two IFCs can be used for interfacing different Ethernet and TDM ports.
Each interface card can be either pure Ethernet IFC (i.e. all Ethernet ports, copper or
fiber) or CES card (TDM traffic to MEF format processing unit).
A2200 IDU does not support Power over Ethernet on GbE ports.
Two Power Supply units are used for powering the system.
The TDM interface card is used for TDM interfaces connections (e.g. E1/T1).
A2200 is connected to a FlexiPacket Radio ODU by a GbE port (copper) on IFC.
Each card provides 8 GbE ports and up to two cards can be equipped in IDU,
resulting in 16 GbE ports totally.
Since one Ethernet port shall be reserved for line-up, maintenance and configuration
upgrade purposes, up to 15 FPR ODUs can be connected to a single A2200.



FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Back Power Supply option
BACK
Access Module Bay Access Module Bay
Fan
Tray
Power Supply
USB Device 4 uplink ports
USB Host Management
Console
Dry Contact
Main Module CES Access Module Bay
8-port
10/100/1000BASE-T
Access Module
E1/T1 CES
Module
FRONT
Power Supply

Fig. 1 FlexiPacket Hub 2200




FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
6

1.1.1 Main Module
The Main Module is the fixed part of the A-2200 device, and is located on the left
side.
Its main characteristics are reported in Fig. 2.
Connectors are shown from Fig. 3 to Fig. 8 .

Main CPU of the unit
Switching capacity (Full Duplex)
Total switching capacity - 24Gbps FD
Network switching capacity - 4Gbps FD
Access switching capacity - 20Gbps FD
4 x GBE uplink interfaces
SFP support (Optical and Electrical))
QOS HW mechanisms
Housekeeping interfaces
System and Alarm LEDs
Alarm Cut Off (ACO)
Dry contacts 4 inputs and 4 outputs
Out Of Band management interfaces (RS232, RJ45 10/100/1000BaseT)
USB interfaces for Disk On Key and UART emulation

Fig. 2 Main Module (1)





FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


Fig. 3 Main Module (2)


FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
8


Fig. 4 Main Module (3)


FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fig. 5 Main Module (4)


FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
10

Fig. 6 Main Module (5)


Fig. 7 Main Module (6)



FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
11

Fig. 8 MainModule (7)
FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
12

1.1.2 Power Supply
The A-2200 device can accommodate one or two of the following removable power
supplies:
Front-facing AC power supply
Rear-facing AC power supply
Front-facing DC power supply
Rear-facing DC power supply
When two power supplies are installed and enabled, each power supply provides half
of the A-2200s input current. If one power supply fails or is removed, the second
power supply automatically provides the full power load. All power supplies are hot
swappable.

AC power supply
DC power supply
Powering capacity
100 W
Supported alarms
Under voltage
Over Temperature
Output Power
Hot swappable and redundant
DC and AC power supplies can be mixed on the
same A-2200

Fig. 9 Power Supply


FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
13

1.1.3 Ethernet Interfaces
The available Ethernet Interfaces are:
10-port 100/1000BASE-FX optical fiber access module. This module has 10 SFP
ports that operate at 100 or 1000 Mbps. For the range and wavelength of optical
ports, see the A-Series Optical Performance Guide.
8-port 10/100/1000BASE-T copper cable access module. This module has 8 RJ-
45 ports that operate at 10, 100, or 1000 Mbps.
Main characteristics about the Ethernet Interfaces are in Fig. 10.
Connections are from Fig. 11 to Fig. 13.

Support 10 optical Ethernet interfaces
100/1000 BaseX full duplex
Auto-negotiation support
Supports standard 2 fiber as well as single fiber SFPs
Both access modules position can house FX-10 cards
Hot swappable
10-port 100/1000BASE-FX
Support 8 copper Ethernet interfaces
10/100/1000 BaseT full duplex
Auto-negotiation and auto MDIX support
Both access modules position can house GE-8 cards
Hot swappable
8-port 10/100/1000BASE-T

Fig. 10 Ethernet Interfaces (1)
FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
14


Fig. 11 Ethernet Interfaces (2)


FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
15

Fig. 12 Ethernet Interfaces (3)

Fig. 13 Ethernet Interfaces (4)
FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
16

1.1.4 E1/T1 CES Access Modules
The available E1/T1 CES modules are:
8-port E1/T1 CES access module. This module enables 8 ports for E1/T1
functionality and contains the LED indications for the user. It can only be located in
the right access bay.
16-port E1/T1 CES access module. This module enables 16 ports for E1/T1
functionality and contains the LED indications for the user.

Two E1/T1 modules supported:
8 x E1/T1
16 x E1/T1
E1/T1 CES Modules requires additional
physical interface modules (TIC)
Installation:
8xE1/T1 module can be installed in right access bay only
16xE1/T1 can be installed in any access bay
E1/T1 CES Modules

Fig. 14 E1/T1CES Access Modules (1)


1.1.5 TDMInterface Card (TIC)
The TDM Interface Card (TIC) is the E1/T1 interface module to the outside world.
One of the following TICs can be installed in the TIC bay at the top right of the A2200
device:
8-port TIC. This TIC provides 8 E1/T1 ports, and is installed with an 8- port E1/T1
CES access module.
32-port TIC. This TIC provides 16 E1/T1 ports when connected to one patch
panel, and 32 E1/T1 ports when connected to two patch panels. The 32-port TIC is
installed with one or two 16-port E1/T1 CES access modules.
8-port CES services are implemented by installing an access module, which enables
E1/T1 functionality, and a TDM Interface Card (TIC) which enables 8 E1/T1
interfaces.
16-port CES services are implemented by installing an access module, which
enables E1/T1 functionality. A TIC is installed together with a patch panel, enabling
16 E1/T1 interfaces.



FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
17

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


32-port CES services are implemented by installing two access modules, which
enable E1/T1 functionality. A TIC is installed together with two patch panels,
enabling 32 E1/T1 interfaces.
TIC Modules and interconnections are shown from Fig. 15 to Fig. 18.

TIC - 8 TIC - 32
16 ports patch panel
Required to connect E1/T1 CES to external world
Module types:
8 x E1/T1 with RJ45 connectors
32 x E1/T1 supporting the 16xE1/T1 modules
A 16 port patch panel for RJ45 is available
TDM Interconnection Modules (TIC)

Fig. 15 E1/T1CES Access Modules (2)



FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
18

Fig. 16 E1/T1CES Access Module (3)

Fig. 17 E1/T1CES Access Module (4)


FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
19

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


Fig. 18 E1/T1CES Access Module (5)

FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
20

E1/T1 Cable pin Assignment are reported in Fig. 19.


Fig. 19 E1/T1CES Access Module (6)


FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
21

1.1.6 CES STM-1 OC-3 Module
This module provides a connection between the customers TDM network and the
Nokia Siemens Networks CET network by supplying Circuit Emulation Services for
STM-1/OC-3.
The module has a user interface located on its front panel and a backplane interface
that connects the main boards signals.
There are four front panel SFP interfaces whose configurable interface types are:
SFP #1 STM-1/OC-3 or STM-4/OC-12 (future)
SFP #2, 3 and 4 STM-1/OC-3
The front panel also contains indication LEDs as follows:
1 x card status: green, amber, red
4 x TDM port status: green, red


Fig. 20 CES STM1 OC3 Module (1)
FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
22

OC3/STM1 CES Access Module Connections are reported in Fig. 21.


Fig. 21 CES STM1 OC3 Module (2)


FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
23

1.1.7 FlexiPacket Hub A-2200 EQUIPMENT COMPOSITION
FlexiPacket HUB A-2200 equipment Composition rules are resumed in Fig. 22.


Fig. 22 FlexiPacket Hub A-2200 EQUIPMENT COMPOSITION

FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
24

1.1.8 A-2200 device LEDs
The ACO (alarm cut off) and LED Test features are provided on the A-2200 main
unit, as shown in Fig. 23.


Fig. 23 A-2200 device LED indications
A-2200 ACO feature
Pressing the ACO button after an alarm has been detected silences an external
device connected to A-2200 through the dry contact port, until another alarm is
detected or the specified timeout is reached.
A-2200 alarm indications
Fig. 24 describes the alarm LED indications for the A-2200 device.


Fig. 24 A-2200 alarm LED indications




FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
25

A-2200 system indications
Fig. 25 lists the A-2200 system LED indications that provide information about the
general operating status of the A-2200 device.


Fig. 25 A-2200 system LED indications
A-2200 management indications
Fig. 26 describes the 10/100BASE-TX out-of-band management port LED indications
for the A-2200 device.


Fig. 26 A-2200 management port indications
Information on troubleshooting is on a dedicated Chapter
FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
26

The LED Test feature
Pressing the LED Test button lights all LEDs, enabling detection of a LED
malfunction.

A-2200 power supply unit indications
Fig. 27 describes the A-2200 power supply LED indications.


Fig. 27 A-2200 PSU LED indications
Information on troubleshooting is on a dedicated Chapter





FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
27

Access module indications
Each access module has various LED indications providing information about its
access ports.
Access Port Indications
Each access port Optical or Electrical) has a green LINK LED and an orange ACT
LED, which indicate the port status, and an OK/OOS LED, which indicates the state
of the entire access module (Fig. 29).
Fig. 28 describes the optical access port LED indications.


WARNING
When a copper access module is disabled, both the Link and OOS LEDs are lit.


Fig. 28 Optical access port indications

FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
28
Copper access port LEDs
Optical access port LEDs

Fig. 29 Optical and Electrical access port LEDs

FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
29

CES port indications
Each STAT/ALARM LED indicates the state of one E1/T1 port. Each column of
STAT/ALARM LEDs is numbered to identify the access port to which the LED
corresponds (Fig. 32). The OK/OOS LED indicates the state of the entire access
module (Fig. 32 and Fig. 33).
Fig. 30 and Fig. 31 describe the CES access port LED indications.
When a CES access module is disabled, both the Link and OOS LEDs are lit.


Fig. 30 CES access port indications


Fig. 31 CES access port indications (continued)
FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
30

8-Port CES E1/T1 access module
16-Port CES E1/T1 access module

Fig. 32 CES E1/T1 access modules


Fig. 33 CES STM-1/OC-3 module


FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
31

1.2 FlexiPacket Hub 1200
The A-1200 is a cost-effective access device for cellular backhaul and enterprise
applications. It has Ethernet ports as well as E1/T1 ports for CES applications.
There are two versions of the A-1200:
modular
fixed

Modular A-1200
The front view of the modular A-1200 device is shown in Fig. 34.

4x100/1000 Base-Fx SFP
6x10/100/1000 Base-T 8xE1/T1

Fig. 34 front view of the modular A-1200

The front view of the modular A-1200 device with a blank panel covering the modular
slot is shown in Fig. 35.


Fig. 35 front view of the modular A-1200 device with a blank panel

The hot surface cautionary symbol refers to the handle of the fan tray which may be
hot to the touch.
FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
32

Fixed A- 1200
The front view of the fixed A-1200 device is shown in Fig. 36.

8x E1/T1 6x 10/100/1000 Base-T

Fig. 36 front view of the fixed A-1200

The hot surface cautionary symbol refers to the handle of the fan tray which may be
hot to the touch.





FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
33

1.2.1 Fan tray
The same fan tray, which contains four fans, features in both the modular and fixed
versions of the A-1200; it is used for cooling the chassis and is field-replaceable. If
one of the fans in the tray should fail, an alarm is generated. Even in the case of a
single fan failure, the A-1200 still supports all environmental requirements.


Fig. 37

1.2.2 DC power supply
Two sources of 36 VDC to 75 VDC can be connected to the fixed DC power supply
unit, the source with the higher voltage feeds the unit and the second serves as the
redundant source.
The input voltage operating range is: 36 V 75 VDC. The maximum input current at
40.5 V is 2 A.

1.2.3 AC power supply (for modular version only)
An input voltage operating range of 85 VAC 265 VAC, 47 Hz 63 Hz can be
connected to the fixed AC power supply unit. The maximum input current at 85 VAC
is 1 A.
FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
34

1.2.4 Main unit
The main unit is the fixed part of the A-1200 device; it contains:
4 optical Ethernet ports (2 in the Fixed version)
100/1000 Base-FX full duplex
100/1000 Auto-negotiation
Small form-factor pluggable (SFP)
LC connector
6 copper Ethernet ports
10/100/1000 Base-T full duplex
10/100/1000 Auto-negotiation
MDIX (10Base-T.100Base-TX)
6 x RJ-45 connector
8 x E1/T1 ports
8 x TDM E1/T1
12V input from PSU
RJ-45 connector (RJ-48C mapping)
Out-of-Band port
Full duplex 100Base-TX IEEE 802.3u compliant
10/100 Auto-negotiation
MDIX
RJ-45 connector
Console port
RS-232 interface
RJ-45 connector
Dry Contact
2 input indications
2 output alarm indications (48V/1 Amp)
DB-9 connector
Universal Serial Bus (USB)
USB 2.0 compliant. The USB port is intended for connection to a computer to
control the unit.
LEDs
OK/Fail, Test/Disable LEDs

FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
35

1.2.5 4-port STM-1/OC-3 CES access module
This module, which can only be used in the modular version, is designed to be
inserted into the modular slot of the A-1200. It provides a connection between the
customers TDM network and the Nokia Siemens Networks CET network by
supplying Circuit Emulation Services for STM-1/OC-3.


Fig. 38 4-port STM-1/OC-3 CES access module


FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
36

1.2.6 A-1200 device LEDs
The types of LEDs on the A-1200 main unit (Fig. 39 and Fig. 40) are:
System
Ethernet port
CES port
Power supply


Fig. 39 Front view of the fixed A-1200


Fig. 40 Modular A-1200 with blank panel



FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
37

A-1200 system indications
Fig. 41 lists the A-1200 system LED indications that provide information about the
general operating status of the device.


Fig. 41 A-1200 system LED indications
Information on troubleshooting is on a dedicated Chapter
FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
38

Ethernet Port
Fig. 42 lists the A-1200 Ethernet Port LED indications.

)
)

Fig. 42 Ethernet port LED indications
Information on troubleshooting is on a dedicated Chapter



FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
39

CES port indications
Fig. 43 lists the A-1200 CES Port LED indications.


Fig. 43 CES port LED indications
Information on troubleshooting is on a dedicated Chapter

A-1200 power supply indications
Fig. 44 lists the A-1200 Power Supply LED indications.


Fig. 44 A-1200 PSU LED indications
Information on troubleshooting is on a dedicated Chapter
FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
40


FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
41

1.3 A 2200/A 1200 Quality of Service (QoS)
A2200 and A1200 support five different queues, each one associated to one of the
following Class of Service:
EF1 (Expedited Forwarding
EF Control and EF2
AF Control and AF1 (Assured Forwarding)
AF2
AF3 and BE (Best Effort)
In the ingress of an UNI/NNI port, traffic is marked/processed using 3 bits (PCP) that
define priority and color as reported in Fig. 45.

0
AF3
BE
1 AF2
2
AF Control
AF1
(Management)
3
EF Control
EF2
4 EF1
PCP Bit Value Color Priority
Queue
CoS
7
6
5
4
3
2
1
0
.
.
Yellow
Yellow
Yellow
Yellow
Yellow
Green
Green
Green
Green
Green

Fig. 45 HUB Priority Code Point Configuration
FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
42

The characteristics of the classes are:
EF1 (Class 4)
Lowest delay and delay variation
No packet loss
Similar to DiffServ Expedited Forwarding
Usually reserved for Circuit Emulation Service (TDM services)
May be used for Voice
Highest strict priority
EF2 (Class 3)
Low delay, delay variation, and no packet loss
Used for Voice, Video, other real-time applications
Second strict priority
AF1 (Class 2)
Low packet loss
Reserved for internal network control traffic (OSPF, configuration,
download etc.)
AF2 (Class 1)
Lower delay and packet loss than Normal Data
Better excess BW treatment than Normal Data
Similar to DiffServ Assured Forwarding
AF3 (Class 0)
Not just Best effort may still have guaranteed BW



ling

FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
43

The scheduling is performed mixing both Strict Priority and Weighted Fair Queuing
(WFQ) mechanisms, as reported in Fig. 46

W
F
Q
S
.
P
.
S
c
h
e
d
u
l
e
r
WFQ
Queues
EF1
EF2
AF1
AF2
BE
SP
Queues

Fig. 46 HUB Scheduling
FlexiPacket Hub


FT4282CEN02GLA0
2010 Nokia Siemens Networks
44

In order to cope with the HUB, The configuration on the ODU shall be as reported in
Fig. 47.

0
AF3
BE
1 AF2
2
AF Control
AF1
(Management)
2
EF Control
EF2
3 EF1
PCB
Bit
Value
Priority
Queue CoS
7
6
5
4
3
2
1
0

Fig. 47 HUB Priority Code Point Configuration