Holley GSM/GPRS Smart Gas Meter Solution

1. Overview
GSM/GPRS Series Smart Gas Meter is a new generation intelligent gas meter developed by Holley, which evolved on prepaid gas meter. It adopts Siemens GSM Module 900/1800/1900Mhz communication module to send consumption data timely to the data center. This AMR technology will make operators benefit from recording the load profile and Input-Output Ratio online.

2. Conform Standards
MID 2004/22/EC and EN12405; IEC 60079-0, 11; UNICN13757, IEC60870;

3. Main Feature
3.1 Working principle
GAS METER WORKING DIGRAM
DEVIATION10PPM (Monthly maximum datetime allowed deviation1minute)

GSM?GPRS

COMMUNICATE

REAL-TIME CLOCK

Gas Leakege Monitor

TWO REED SENSOR ACQ ELECTRIC SQUARE

MEASURING DATA ACQUISITION

MAIN BOARD

ELECTRO VALVE

Embeded High Density Energy lithium Cell Working lifetime10 Year

POWER SUPPLY

LCD/ALARM

1. with pressure presetting, 2. USE Pt trasducer(platinum resistence) to measure Temperature , then correct the Correctedted the metrology data To STANDARD condition

3.2 General Description

MCU: Using TI or MICROCHIP Companys SCM, low power dissipation and high performance.

Powered by built-in 12AH li-battery, service life >10 years Using mature dual reed switches measuring technology. Communication Module: GSM 900/1800/1900MHz Electro-valve: high reliable, lower voltage loss, low power dissipation. Clock Module: Using high accuracy clock chip from Dallas Company, clock offset10PPM.

Temperature compensation: Adopting PT1000 sensor, conform to EN60571 A Class

Communication Interface: Using standard RS232, protocol is definable.

Allowing interface of gas leaking alarm.

3. 3 Tariff Calculation
Following parameters can be recorded automatically: Users information in five different time intervals. Time point of calculating could be preset. Gas consumption records of recent one hundred days could be saved and easy to get the gas consumption curve at any time interval.

3.4 Clock correction and Synchronization


Our gas meter has built in clock with perpetual calendar. The monthly maximum time error is less than one minute. Clock can be synchronized by handheld pc or the radio instruction from the administration centre.

3.5 Valve Control


Our gas meter has a built in electro-valve, to control the users gas consumption. Under abnormal conditions like, battery running out, built in EEPROM damage, measuring sensor damage, abnormal flow-rate, backing up meter parameter error, gas meter will shut down valve automatically. After fixing errors, valve

can be re-opened by pressing the trigger button or switching off and switching on the power supply.

3.6 Display
Our gas meter has both register display and LCD display. Without users operation on meter, LCD screen will keep shut in order to preserve battery power. When display button being pressed down, LCD screen will light on. After releasing display button for sixty seconds, meter will enter low power consumption mode, at the meantime LCD screen shuts down. The default display content is accumulated gas consumption. By keep pressing the display button, other information will display in turn. Displaying information is

accumulated gas consumption, recent month gas consumption, present time, gas meter serial number.

3.7 Alarm Function


Under the condition like battery running out, electro-valve error, abnormal clock error, the gas meter will alarm and display alarm information on the LCD screen.

3.8 Measurement data upload


Our gas meter will upload users information to administration centre regularly. The frequency of uploading is adjustable by the administrator.

3.9 Self-diagnostics and event in time report function


Our gas meter could carry out self-diagnostics aiming at the condition of meter internal operating. And the information of self- diagnostics is as follows: The accuracy of clock Whether the remaining energy of battery is sufficient or not. Once the inadequate remaining energy of battery is being detected, it will report to administration centre for the in time battery replacement.

Whether operation of Valve is normal or not. Whether the condition of memory is normal or not. Whether the condition of measuring sensor is normal or not. Whether the parameters of internal operation are normal or not.

3.10 Operation parameters recording


Our gas meter can record operation parameters automatically. And these parameters are as follows: The number of times of magnetic disturbance and the happened time of latest magnetic disturbance. The number of times of battery replacement and the happened time of latest battery replacement. The number of times of high flow rate and the happened time of latest high flow rate. The number of times of illegal open of meter cover and the happened time of latest meter cover open. Gas meter alarm and the happened time of latest gas leakage.

3.11 Temperature compensation


GSM Series smart gas meter G1.6-G4 have the characteristic of temperature compensation. Built-in software will automatically transfer the value detected into standard environments value1.01325 bar15 C FormulaVb=(Pm/Pb) *(Tb/Tm)*(Zb/Zm)*Vm Its accuracy to reach the European standards of measurement EN12405 Note: 1000 sample meters will do not have the above functions, but the data format has reserved the words byte for this function. After sample meter period, we will supply you with this function, and the same time, Display way will use LCD only.

3.12 Authorized valve open through long distance


Management system can authorize users to open valve through wireless network. The

electro-valve will shut down automatically due to users illegal operation or gas meter fault. After fault being ruled out, user can make an application of re-open valve to administration centre, and administration centre can authorize user through long distance. After accepting the authorization, then user can open the valve by pressing the button on the gas meter.

3.13 Data transmission


To make sure the safety of data trasmissiting, this meter adopts international universal DES encryption.

3.14 Maintenance & Management


It is easy to manage the smart gas meter. This meter can exchange data with data center bidirectional, and also can exchange data with HHU locally. Operator can download the Key, can configure the setting, and the same time can read data through HHU device.

3.15 Online configuring tariff function


This smart gas meter has the characteristic of online configuring tariff. Operator will benefit from this function.

3.16 Software updating


Interface is reserved to update software. We will supply you with device to update software. So, it will be very convenient for operator to updating software.

4 GSM DTU main features


4.1 Product Specifications 4.1.1 Voltage Specification: 3.6V (Input), high capacity lithium battery 4.1.2 Data capacity specification: Gas meter data stored in local memory, and memory
can be extended.

4.1.3 Module specification: Siemenss industrial communication module adopted, 4


frequency bands supported.

4.2 Functions 4.2.1 Support working in SMS mode or GPRS mode 4.2.2 Support setting of intervals for collecting and uploading data 4.2.3 Support checking of local GSM signal strength 4.2.4 Support remote reading of gas meter ID 4.2.5 Support local and remote time calibration

4.2.6 Support local storage of collected data, which memory can be extended as per
customer requirement

4.2.7 Support real-time battery indication. The low battery threshold can be configurable
to alert the users to change the battery.

4.2.8 Support setting of system working hours for extending battery life

HT6000 GSM DTU

Base Gas meter

4.3 Hardware working principle

NULL

Voltage Testing

Power Supply management Output: 4.2V 3.3V

Battery Input

Gas meter data acquisition interface Clock Battery RS232 interface Hardware Clock MCU Siemens module system

Jumper testing input


Data storage

LED Indication

LED Indication

SIM card slot

4.4 Main functions 4.4.1 Low consumption: The DTU can be waked up passively by the gas meter or
actively by the system on schedule. In working mode, the DTU can passively accept the gas meter push data or actively pull to read the gas meter data

4.4.2 High capacity data storage: According to the protocol, the data stored can be read
through RS232 interface and the memory can be extended according to the data volume.

4.4.3 Working mode setting: The DTU can work in SMS mode or GPRS+SMS mode. 4.4.4 SMS center setting: Maximum 15 bytes. Please consult the local mobile operator
to get the parameter.

4.4.5 Group SMS: Users can specify more than one data centers to upload the data to
multiple data center servers.

4.4.6 Interval of data acquisition: 10-50000 min as per customer requirement. The
battery life can be extended if the interval is set to be longer.

4.4.7 Interval of data uploading: 10-50000 min. 10-50000 min as per customer
requirement. The battery life can be extended if the interval is set to be longer.

4.4.8 DTU online time: 30-1800 sec. The energy consumption of the module can be
controlled in order to extend the battery life.

4.4.9 SMS data processing mode: It supports transparent mode and local storage mode;
if the data cannot be uploaded due to network failure, the data can be stored in local memory to ensure that the data will not be lost.

4.4.10 DTU ID: 12 byte for DTU ID; the local gas meter address can be inquired. 4.4.11 GSM status: Users can inquire the GSM signal strength to avoid low
communication success rate caused by the poor quality of local network.

4.4.12 Battery level inquiry: Users can set a threshold to trigger the low battery
alarming and inquire the voltage of the battery. In low battery mode, reminders will be sent to the users for battery replacement.

4.5 Battery features and Sleeping Strategy


4.5.1 Battery Type We use high capacity and power battery which is safe and stable with low self-consumption 4.5.2 Energy-saving Strategy

The system works in three working modes: Sleeping mode, data-receiving mode and data-uploading mode. Workflow: After the system is powered, the DTU enters the data-receiving ready mode. If no data is received, it enters the sleeping mode. When the DTU is in sleeping mode, the system can be waked in two ways: 1: The system can be waked by the gas meter module to enter the data-receiving mode. It returns to sleeping mode after the data receiving is completed. The waking time interval is set according to the data-acquisition interval of the gas meter. 2: The system enters data-uploading mode. After the data uploading is completed, it enters the sleeping mode again. 4.5.3 Battery Consumption Analysis We use 12AH high power lithium battery which is very popular and easy to be sourced in the market. Working parameter and mode: Interval of data acquisition: 180 min, uploading interval: 4320 min (3days)DTU online time: 300 sec. Based on the above parameters, the system can work for 9 years.

5 Specifications of Uplink and Downlink SMS


All SMS data length should be less than 140 bytes. All parameters can be configured through serial port or SMS: The serial port is mainly used for local configuration while SMS is mainly used for remote configuration. The SMS setting is illustrated as below:

The tree structure in the left includes all the node names and the corresponding phone numbers. If the SMS mode is selected, the messages should be sent according to the format as below: Header of SMS uplink frame + SMS content The SMS uplink frame starts like this: SMSsend13116742086F, among which SMSsend is the beginning, followed by 3-15 byte target phone number and ended up with F, and plus the content to be send. For example, to set the working mode of the data center, assume the password is 123456 and working mode 1. Then format of SMS message is: SMSsend13116742086F*SET123456WKMD=1& Responding frame of server DTU for downlink data The frame header returned: SMSback13116742086F For example: SMSsend13116742086F*SET123456WKMD=1& Responding data:

Sent successful: SMSback13116742086Fsetok Sent failed: SMSback13116742086Fsetfaulure GSM closed: SMSbackGSMclosed

5.1 The DTU Formats of Downlink SMS message format mainly includes 4 types: reading format, setting format, special format and sending format.
5.1.1 SMS format outline SMS format setting: *read-write operationpassword of 6 digit one or >one query items&,the query items are separated with #. Starting symbols *

Read-write operation GET&SET 6 digit password: admin password is HTGPRSinitial password is 000000. One or >one query items: the parameters are separated with #. Ending symbol & After read-write success, a SMS will be returned. 5.1.2 SMS setting A SMS will be returned after successful setting For example: To set the IP address of data center, imagine the password is 123456,IP address is 192.168.1.1,then the SMS format is : *SET123456DCIP=192168001001& To set the serial interface number of data center, imagine the password is123456 serial interface number is2008 then the SMS format is *SET123456DCPT=02008& To set multiple data formats, imagine the password is 123456,IP address is 192.168.1.1, the communication port number of data center is 2000the APN is CMNET heart beat cycle is 8, then the format is: *SET123456DCIP=192168001001#DCPT=02000#GAPN=CMNET#HBCY=5& 5.1.3 SMS Read

To read the IP address and the communication port number of data center, imagine the password is123456, the read format and returned SMS format are : Read *GET123456DCIP& Responding *GETDCIP=192168001001# To read multiple parameters, imagine the password is123456 the read format and returned SMS format are : Read*GET123456DCIP#DCPT#GAPN#HBCY& Responding *GETDCIP=192168001001&DCPT=02000&GAPN=CMNET&HBCY=005# 5.1.4 Special command Re-link GPRS network command. *SET123456RLIK& Re-linked GPRS network command returned *SETOK#>>12345678RELIKING 5.1.5 Sending message The data sent is the data set in the textbox, either HEX or asc. SMSsend13116742086F123456789

6. DTU Software Management Workflow


The PC software collects all the uploaded data and performs data analysis and exporting functions.

7. DTU Functions (optional)


The GPRS function is optional to send the data to the target server. The cost will be comparatively lower especially for transmission of large data volume (SMS service is charged per message while GPRS is charged according to the data volume). The GPRS function is more complex and the battery consumption will be higher (More steps to access GPRS). The advantage is that large volume data can be sent (SMS can contain max 140 bytes while a GPRS packet length can be 1500 bytes at maximum)

8. Note
DTUfull name: Data Transmission unit DTU terminal ID: Set by user, the ID of the module SMS : Text message Working mode : SMS mode &GPRSTCPUDPmode; In SMS mode, only SMS function supported.

9. Network topography

BILL &MANAGEMENT SYSTEM


WEB SERVICE

client firewall client

client

router

internet

CDMA/GSM/GPRS

operator

operator

operator

Before deploying smart gas meter, Operator should set up customer profile in the management system, and then write user information into SIM Card. Once this SIM card is inserted into smart gas meter, smart gas meter complete its register process.

10 Electronic part specifications


Conform standards

EN1359 and OIML R31 3 Tariffs,

Accuracy Class

Class 1.5

Tariff and TOD

5TOD intervals

Backup Battery

3.6VDC, Cap. 12AH NOT LESS

RTC accuracy Static working current(without GSM)

0.5s/d(23)

Batterys Life

THAN YEARS

10

10 A

Operational temperature Explosion-Proof class

-20 ~50

Average Rel.Humidity Basic measuring unit

93%

BB

0.01 m3

11 Base meter specification


Model G1.6 1.6 2.5 0.016 G2.5 2.5 4 0.025 200 0.530 kPa 0.550 kPa 1.2 3 1.5 0.2 9999.999 99999.999 -20+50 -20+60 110 M30x2, 3/4, 1"1/4 customized) mm kg 225x195x170(H W D) 2.00 (or by G4 4 6 0.040

Item Nominal flow-rate (Qn) Maximum flow-rate (Qmax) Minimum flow-rate (Qmin)

Unit m 3/h m 3/h m 3/h

Total pressure absorption Pa Operation pressure range Cyclic volume Permiss ible error QminQ<0.1Q max 0.1QmaxQQ max kPa dm3 % % dm3 m3 mm

Min. recording reading Max. recording reading Operational ambient temperature Storage temperature Central distance Connection thread Dimension Weight

Outside casing Service life Surface painting Index cover years

Quality steel sheet, thickness is 0.8mm 15 Polyester powder plastics coating (gray) Printed index cover of polycarbonate or index cover of aluminum bezel with glass.

12. Electro-valve specification


Actuating medium Current capacity scope Working pressure scope Relative humidity Pressure loss Sealing property (outside) Sealing property (inside) Durability Working current Working voltage Peak current Opens and close cycle Structure Natural gasCoal gasLiquefied petroleum gas 0~6m /h 0~4.2KPa 90% 50Pa No leakage under 20KPa 10KPa (3min)120pa Normal working>10000 80mA(3V) DC3~6V 220 mA (3V) 2S 0.1S (3V) The material uses Metaformaldehyde Rubber