You are on page 1of 12

SPE 139713

The Effect of CO
2
-Saturated Brine on the Conductivity of Wellbore-Cement
Fractures
Tevfik Yalcinkaya, SPE, Mileva Radonjic, Richard G. Hughes, SPE, Clinton S.Willson, Kyungmin Ham, Louisiana
State University
Copyright 2010, Society of Petroleum Engineers

This paper was prepared for presentation at the SPE International Conference on CO2 Capture, Storage, and Utilization held in New Orleans, Louisiana, USA, 1012 November 2010.

This paper was selected for presentation by an SPE program committee following review of information contained in an abstract submitted by the author(s). Contents of the paper have not been
reviewed by the Society of Petroleum Engineers and are subject to correction by the author(s). The material does not necessarily reflect any position of the Society of Petroleum Engineers, its
officers, or members. Electronic reproduction, distribution, or storage of any part of this paper without the written consent of the Society of Petroleum Engineers is prohibited. Permission to
reproduce in print is restricted to an abstract of not more than 300 words; illustrations may not be copied. The abstract must contain conspicuous acknowledgment of SPE copyright.


Abstract
The efficiency of Carbon Capture and Storage projects is directly related to the long term sealing ability of cemented sections
in wellbores penetrating CO
2
storage reservoirs. The microfractures inside the wellbore cement and/or microannulus are
possible pathways for CO
2
leakage to the surface and/or fresh water aquifers and jeopardize safe and long-term containment
of CO
2
in the subsurface.

This paper presents an experimental study which investigates the changes inside the cement internal structure when exposed
to acidic brine through an artificial fracture. A 30-day long flow through experiment was conducted using a 1 in by 12 in.
cement core and CO
2
saturated brine, as a permeant, at a flow rate of 2 ml/min in a core flooding apparatus with10 psi and
600 psi of injection and net overburden pressures (Low Pressure-LP experiment). The same experiment was repeated with
1800 psi and 600 psi of injection and net overburden pressures for 10 days in order to account for the effects of pressure on
the degradation process of cement (High Pressure-HP experiment). High-resolution X-ray computed tomography was used to
image several subvolumes extracted from the flow-through cores. The images were processed and thresholded, followed by
calculation of porosity. Total porosity was observed to decrease from 26% to 22% after 30 days of exposure of LP
experiment. The HP experiment did not cause any significant change in total porosity possibly due to the short duration of the
experiment.

Introduction
At the current state, Carbon Capture and Storage (CCS) technology offers a feasible solution to mitigate the problem of
increasing atmospheric CO
2
. Risk assessment of a CO
2
storage project requires an evaluation of the integrity of the wellbore
network to be analyzed against the possible leakage scenarios over extended time scales (Bachu, 2009). An understanding
about the behavior of microannulus or cement fractures under sequestration conditions is essential in order to analyze the
integrity of existing wellbores and their extended service life under conditions for which they may not have been designed.
Wellbore cement (pore fluid pH~13.5) will be in contact with acidic brine (pH ~3-5) in the post injection period, where the
incompatibility arises from contact of two systems with widely different pH values. Hence, the cement behavior under
dynamic CCS conditions needs to be investigated before implementing large scale projects. This was the main motivation for
this experimental study.

Wellbore Cement
Oil and gas (O&G) wells are cased and cemented in order to provide zonal isolation, structural support for the wellbore and
protection of casing against corrosive fluids such as CO
2
and H
2
S rich brines. Maintenance of zonal isolation is the most
important function of wellbore cement in CCS projects because it prevents both horizontal and vertical hydraulic
conductivity within and into the wellbore. Nelson (2006) reports that some 11,000 casing strings in over 22,000 oil and gas
wells in the Gulf of Mexico have been reported with sustained casing pressure which is an indication of inadequate zonal
isolation. Most oil and gas wells are designed for 30-50 years of service life; however, CCS projects will require wellbore
cements to maintain zonal isolation function for hundreds of years. The cause of wellbore leaking is frequently related to
cement failure, which can be due to inadequate cement design or ineffective placement of cement (procedures, equipment,
and technical inadequacy).

2 SPE 139713
Wellbore Cement Failure
Wellbore cement failures can occur during and after cementing operations. During cementing operations, insufficient mud
removal and improper cement placement may finally lead to weak bonding at cement/casing and/or cement/formation
interfaces and eventually gas channeling within the cement column. After the cement slurry has been set, it will be subject to
varying loads due to repeated pressure and temperature cycles caused by field operations (Ravi, 2004). Since the thermal
expansion and elasticity coefficients are different for casing and cement, the casing and cement expand and contract at
different rates which increases the possibility of forming a microannulus between the casing and the cement and may also
cause fracture initiation and propagation within the cement. In this study, the main focus is the interaction between CO
2
rich
brine and a single fracture within the cement sheath.

Cement Chemistry
The main constituents of Portland cement are calcium and silica. It has four major crystalline products (Nelson, 1999);
Tricalcium Silicate (Ca
3
SiO
5
), also known as Dicalcium Silicate (Ca
2
SiO
4
), Tricalcium Aluminate (Ca
3
Al
2
O
6
), Tetracalcium
Aluminoferrite (Ca
4
Al
2
Fe
2
O
10
). The silicate phases comprise more than 80% of the Portland cement. After complete hydration of
cement (hydration starts when cement comes in contact with water), two main products are formed; Calcium Silicate Hydrate
(C-S-H) which constitutes 70% of the hydrated cement and is the main binding material, and Portlandite (Ca(OH)
2
) which
occupies 15- 20 % of the volume after hydration. There are also other minor minerals formed as a result of hydration such as
Ettringite ((CaO)
6
(Al
2
O
3
)(SO
3
)
3
.32 H
2
O). During preparation of the cement slurry, air bubbles can be trapped and can lower
cement strength.

Chemical Reactions between Cement and CO
2
Saturated Brine
Portland cement consists of Tricalcium Silicate (C
3
S), Dicalcium Silicate (C
2
S), Tetracalcium Aluminoferrite (C
4
AF)
Tricalcium aluminate (C
3
A). Hydrated Portland cement consists mainly of calcium silicate hydrate (C-S-H), as the main
binding material, Portlandite (CH), unhydrated cement minerals and, in the case of a well cement slurry, a high proportion of
pore water. When hydrated cement is exposed to CO
2
saturated brine, a series of chemical reactions take place; i.e., (adapted
from Lea`s Cement Chemistry Book, 2004)

(1)
(2)
(3)
(4)

When all of the Portlandite/calcite are depleted, the next Ca
2+
source, C-S-H will start leaching Ca
2+
and consequently be
converted into an amorphous structure, resulting in soft cement that has no mechanical integrity (Brandl, 2010).

Methodology
Brine (2% salt solution) was prepared using distilled water and NaCl and KCl salts. A CO
2
saturated brine solution was
prepared

by bubbling CO
2
through the brine solution. The pH of brine solution ranged from 4.9-5.2, to simulate potential post
injection composition of the brine, which could be buffered by dissolved minerals. The experimental set-up consisted of a
Hassler cell, syringe pump, hydraulic pump, data acquisition system, filters and pressure gauges which were installed in
several locations in the flow stream (Figure 1). The Hassler cell was mounted vertically on a stand position to mimic the
upward flow of CO
2
rich brine through the fractured vertical wellbore cement column.

Cement cores (1 in 12 in) were prepared from class-H cement with water to cement ratio 0.38 according to API RP-10B
specifications. The cement slurry was then degassed using a vacuum pump and poured into molds (Figure 2a). The cement
halves were allowed to set for 24 hours. The cement core halves were cured by soaking for 6 months for LP experiment and
120 days for HP experiment in a tap water bath. The cement halves were glued using epoxy along the edges to obtain a 1 in
12 in cement core (Figure 2b).

A low pressure set of experiments were conducted at atmospheric conditions and pressure transducers (0-50 psi) were
selected to ensure the detection of small pressure changes. Pressure transducers capable of measuring 0-5000 psi were used in
a similar set of experiments conducted at higher pressures (1800 psi). The pressures along the core including the injection and
confining stresses were recorded using software written at the Louisiana State University (LSU) Petroleum Engineering
Research and Technical Training Laboratory.

A dual syringe pump system with a 507 ml maximum capacity was utilized and set to single pump auto-refill mode to
provide continuous flow during the experimental period, approximately 24 hours. A nitrogen-charged back pressure regulator
was utilized to achieve higher injection pressures.

SPE 139713 3


Figure 1. Schematics of experimental set-up



Figure 2. Cement preparation mold (a) and cement core (1 in. x 12 in.) (b)









Figure 3. Cement core halves assembled to mimic single fracture (a) locations of samples prepared for different analytical
techniques (b,c)

After CT scan data acquisition each core was dissected as shown in Figure 3, in order to have systematic information
gathered from each section of the core. This was critical since all characterization techniques were of destructive nature and
samples could not be reused, meaning that data sets were from different locations within the core. In order to understand
these processes, various material characterization techniques that complement each other were used. Before starting the
experiments, the cores were scanned using X-Ray Computed Tomography (CT) as a control. Effluent brine (brine after
flowing through the fracture) was analyzed using Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES).
After completing the experimental runs, reacted cores were analyzed using X-Ray Diffraction (XRD), Environmental
Scanning Electron Microscopy (ESEM), Mercury Intrusion Porosimetry (MIP), CT and High Resolution CT (micro-CT).

Micro-CT (High
Resolution CT)
MIP analysis

ESEM

Micro-CT (Low
Resolution CT)
Fracture
Surface




3 mm 5mm cement core
Section 1-2
Section7- 8
Inlet (Section 7-8)
4 SPE 139713
Results and Discussion

X-Ray Computed Tomography (CT)
Non-destructive CT-scans (Figure 4) were acquired prior to the flow experiments (Figure 4a and 4b) and following the flow
experiments (Figure 4c and 4d). The characterization was performed on as-received samples immediately after cement/fluid
contact, thereby minimizing sample alteration. Cement samples were scanned using a Picker PQ5000 CT scanner. The spatial
resolution was 0.25 mm and the slice thicknesses were 2 mm. The cement core was scanned at 8 different locations along the
core from bottom to top (top refers to outlet and bottom refers to inlet) at 140KV.



a

b

c d
Figure 4. CT scans of the unreacted (a,b) and reacted cement (c,d) showing the dissolution along the fracture walls (shown in darker
color due to mass reduction)


Visual image analysis of CT scans revealed that there were density variations within reacted cement matrix along 12inch
core. Most notably the density difference was observed between inlet and outlet section, see Figure 4c, 4d. In addition section
labeled 4 on the CT scan (Fig 4c) suggested a presence of higher density material, most likely due to the deposition of
secondary calcite, also supported by microstructural analysis reported in section on ESEM. Based on qualitative image
analysis, sections of the cement core were then selected for further characterization. Thin slices near the outlet (1-2), the inlet
(7-8) and two sections in the main core body (3-4 and 5-6) were cut using a diamond saw for microstructural investigations.
Outlet

Inlet
Outlet

Inlet
SPE 139713 5
High Resolution Imaging
High-resolution X-ray tomography images were collected at the Louisiana State University Center for Advanced
Microstructures & Devices (CAMD) Tomography beamline. Cement cores (3 mm diameter by 5 mm length), were drilled
from reacted cores from LP experiment (Figure 5), and imaged at 2.5 m spatial resolution at 34 keV monochromatic X-ray
energy. Reconstruction of the 1522 projection images (0.25 angle increment ) or 766 projection images (0.5 angle
increment) between 0 to 180 was performed using a MatLab program based on filtered back projection and correlated
sampling to reduce most systematic errors.




Figure 5. A small section (2.24 2.25 2.01 mm
3
) of the
1.5 1.5 mm
2
by 5 mm imaged cement core.
Porosity analysis was conducted on this small section.


Porosity Quantification
Given the 2.5 micron voxel size of the micro CT
images obtained at CAMD, it is only reasonable to
expect us to be able to identify pore sizes that are 5
microns or larger. Two subvolumes were extracted
from the image volumeone in region A and one in
region B. The grayscale images were converted into
binary images (i.e., solid and void) using a simple
thresholding algorithm in ImageJ. Once the two
phases were identified, the porosity was calculated
by simply calculating the volume fraction of each
phase. The porosity values were found to be 0.027
and 0.046 in regions A and B, respectively. For the
particular subvolumes analyzed, that the volume
fraction of void space that is on the order of 5
microns or larger seemed to decrease in region A
(the region in contact with CO
2
).














A Slice #1 LP_1-2 b Slice# 77 LP_1-2


c Slice #217 LP_1-2 d Slice #297 LP_1-2

d Slice #352 LP_1-2 e Slice #501 LP_1-2
Fracture Surface
B
A
Figure 6. Axial Slices in z-direction showing the internal structure
alterations along the 5 mm core, drilled perpendicular to the fracture
surface

Inner portion of the core
A
B
In previously reported data (Radonjic, 2010) the
similar trend was observed on cement exposed to
acidic brine for 8 weeks, at atmospheric conditions.
Most likely due to the extended time of that
experiment 3 distinct regions were identified in
images scanned at 5.06 micron resolution. The
same procedure as described above was applied
and estimated porosities were 0, 0.005, and 0.02. In
this case, pore sizes that are 10 microns or larger
were identifiable.


B A
B B
B
B
A
A
B
6 SPE 139713
Mercury Intrusion Porosimetry (MIP)
The MIP method is one of the standard procedures to establish the pore size distribution of a porous media, in this case
hydrated cement. The MIP can capture connected pores but not disconnected pores and assumes that pore size distribution is
not affected by the drying process, (Abell, 1999).

The number of pores was calculated assuming that all pores are spherical. Given an incremental volume of injected mercury,
the number of pores is the ratio of the incremental volume to the calculated volume of each pore. The designation
Control_LP stands for the unreacted cement core whereas, LP_7-8 stands for the inlet section of the reacted sample at low
pressure.

The high pressure (HP) experiment increased porosity slightly, control sample of 21.26 % to reacted sample with 21.64 %
porosity (Table 1), however this increase may in fact be within the error limits of the measurement tools. On the other hand,
low pressure (LP-five reported sections and the control sample) experiment resulted in reduction of total porosity. There were
four distinct pore size ranges: 30-70 m (large pores), 10-30 m (medium pores), 0.5-10 m (small pores) and 0-0.5 m
(nano pores).

Table 2 tabulates results obtained from the comparison of unreacted and reacted samples for low pressure and high pressure
experiments. The increment or reduction in percentage pore volumes was observed even in the sub-ranges of defined pore
sizes, as shown in Table 2-section on nano-pores. The reduction in the total pore volume of large pores in LP and HP
experiment may be caused by two potential mechanisms: calcite (Ca(CO
3
)) precipitation inside the pores, causing the actual
pore volume reduction or due to the plugging of pore throats connecting the large pores.

















Table 1. Total porosity values derived from MIP

Pore Size Range
(m)
Low Pressure Experiment_ Section 7-8
(Inlet for Flow-through fluid)
Percentage of a given pore range over
the total pore volume
Low Pressure Experiment_1-2
(Outlet for Flow-through fluid)
Percentage of a given pore
range over the total pore
volume
High Pressure
Experiment
Percentage of a given
pore range over the
total pore volume
Large Pores
30-70 m
Unreacted>Reacted Reacted >Unreacted Unreacted>Reacted

Medium pores

10-30 m
Reacted>Unreacted Reacted>Unreacted I. Unreacted=Reacted
around 30 m
II. Reacted>Unreacted
around 20 m
III.Unreacted>Reacted
around 10 m
Small pores
0.5-10 m
I. Between 5-10 m, Reacted>Unreacted
II. Reacted>Unreacted
Reacted>Unreacted Unreacted>Reacted

Nano pores
0-0.5
m
I. Between 0.1-0.5 m,
Unreacted>Reacted
II. Between 0.005-0.1 microns,
Unreacted>Reacted
I. Between 0.1-0.5 m,
Unreacted>Reacted
I. Between 0.1-0.5
m,Reacted>Unreacted
II.Unreacted>Reacted,
0.1-0.05 m
Table 2. Comparison of percentage pore volumes of different pore size ranges: Large pores 30-70 m, Medium pores 10-30 m,
Small pores 0.5-10 m and Nano pores 0-0.5 m. U refers to unreacted cement sample and R refers to
reacted cement sample. I, II and III refer to different sub-ranges within each pore size range.



Sample Identification Total Porosity
Control_LP 26.33%
LP_1-2 20.43%
LP _3-4 22.94%
LP_4-5 22.01%
LP_5-6 20.79%
LP_7-8 20.50%
Control_HP 21.26%
Reacted_HP 21.64%
SPE 139713 7
Figure 7 shows the plot of applied injection pressure versus the cumulative intrusion of mercury. The most dramatic changes
in pore size are observed between 100-2,000 psi for HP experiment, with a substantial porosity increase with acidic brine
exposure. For the LP experiment most evident difference in pore size distribution is observed between 3,000-60,000 psi,
where porosity decreases with exposure to acidic brine. The possible explanation for these contradicting trends in pore
volume of cement matrix affected by CO
2
rich brine for HP and LP experiments is simultaneous presence of two reaction
mechanisms: leaching of Ca, causing increase in porosity and secondary carbonation causing reduction in porosity. This data
is in agreement with data published by Van Gerven et al. (2007).


Figure 7.Cumulative Intrusion versus Mercury Injection Pressure

Figure 8a and 8b outlines pores size distribution differences between control samples cured for LP and HP experiments. It is
clear that for pore size range 0-0.075 m HP control sample has higher porosity than LP control sample. However, the next
pore size range 0.075-0.5 m LP cement appears to have higher porosity.

In the next pore range 0.5- 50 m LP continues to have higher porosity than HP. The final measured pore range 50-70 m
both samples have similar porosity.

Figure 8c and 8d shows MIP data for HP experiment, pore volume distribution change due to acidic brine exposure. The first
pore range 0-0.045 m there is no apparent change on porosity. From 0.045-0.07 m pore volume distribution shifts to the
left, effectively pointing to reduction in pore volume. The next range 0.008-0.12 m the reduction is minimal. Pore range
0.12-0.5 m increase in pore volume in reacted sample is more evident. From 0.5 to 3.5 m minimal number of pores was
identified in both samples. Reacted cement has undergone further pore volume reduction in the range of 3.5-20 m. In the
final measured range 20-80 m (apart from few data points) reduction in pore volume is still observed.

Figure 8e and 8f represent MIP data for LP experiment for the inlet section of the core. We primarily observe reduction in
pore volume apart from the pore size range from 0.5-30 m where substantial increase of pore volume is measured.
For LP experiment of the outlet section reduction of the pore volume is only observed in ranges from 0-0.05 m and 0.1-0.5
m. The large pore sizes are more present in reacted samples, therefore result in increased porosity.
8 SPE 139713






















































Figure8. Pore Size versus its volume percentage in total pore volume for each experiment






a. Pore size range 0-0.5 m for unreacted samples b. Pore size range 5-70 m for unreacted sample
c. Pore size range 0-0.5 m for HP experiment

d. Pore size range 5-70 m for HP experiment
e. Pore size range 0-0.5 m for LP_7-8
f. Pore size range 5-70 m for LP_7-8
g. Pore size range 0-0.5 m for LP_1-2 h.Pore size range 5-70 m for LP_1-2
SPE 139713 9
Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES)
Effluent brine samples were analyzed using ICP-OES in order to verify Ca
2+
was leaching from the cement during acidic
brine exposure (Figure 9). This method is also called as ICP-AES (Atomic Emission Spectroscopy). In these measurements,
excited electrons emit energy at a given wavelength as they return to ground state after excitation by high temperature Argon
Plasma. The fundamental characteristic of this process is that each element emits energy at specific wavelengths peculiar to
its atomic character. The intensity of the energy emitted at the chosen wavelength is proportional to the amount
(concentration) of that element in the sample being analyzed. Thus, by determining which wavelengths are emitted by a
sample and by determining their intensities, elements can be found qualitatively and quantitatively from the given sample
relative to a reference standard. Figure 9 shows that Ca
2+
leached from cement quickly at the beginning of the experiment.
Later, leaching is reduced probably due to the formation of calcite, which provides an impermeable layer to prevent further
ingress of acidic brine into cement matrix.



Figure 9. ICP-OES analyses for the effluent brine showing Ca
2+
leaching from the cement.


Environmental Scanning Electron Microscopy (ESEM)
Portions of unreacted and reacted cement core samples were imaged using ESEM for microstructural characterization. ESEM
was deployed to further investigate the nature of altered zones within the cement at a much finer scale and under low vacuum
conditions in order to prevent cement dehydration during the analysis. Energy Dispersive Spectroscopy (EDS) was also
utilized to provide chemical composition of various features within the cement structure.

Figure 10a, c and e represents a sequence of ESEM images from low pressure experiment at the inlet region of the core.
Figure 10a taken from the cross section of the core shows sustainably enlarged fracture aperture and secondary
microfractures across the entire sample. EDS analyses Figure 10b) from this region shows Ca/Si ~2:1. In Figure 10c, image
was taken from the fracture wall exposed to the acidic brine flow and supported by EDS analysis (Figure 10d). This region
has an increased Ca/Si and Fe rich phases present. The final image at much higher magnification shown in Figure 10e reveals
columnar crystal growth on the fracture wall coupled with EDS which suggests Ca rich minerals. Similar observation of Fe
rich deposits in reacted cement was reported by Duguid et al. (2005).

Similar trends were observed for LP outlet region of the cement core shown in Figure 11a, c and e. However, major
difference between inlet and outlet regions is the chemical composition of deposits on the fracture wall (Figure 11e,f). In the
outlet region fracture wall is covered by calcite like minerals. Furthermore, the outlet region appears to have a set of
perpendicular fractures to the main fracture wall that are clearly undergone dissolution and secondary precipitation, as shown
in the central portion of the micrograph in Figure 11c.
10 SPE 139713


Figure10. ESEM micrographs of Low-pressure reacted cement core at the first contact with acidic brine (LP 7-8- INLET)



a Low mag. BSD ESEM image of reacted fracture top view b EDS analysis of the cement not in direct contact with brine


c Micrograph of the fracture wall after splitting the core d EDS of the fracture wall surface reveals lower Ca/Si from above


e High mag ESEM micrograph from fracture wall flow area f EDS from fibrous - Ca rich deposits within fracture wall
SPE 139713 11


a Low mag BSD ESEM image of reacted fracture top view b EDS analysis of the cement not in direct contact w/t brine


c Micrograph of the fractured wall surface secondary fracs. d EDS data confirms Ca-rich deposits within secondary fractures


E High mag ESEM micrograph from fracture wall flow
area
f EDS from highly porous area within fracture wall / Ca-rich plates


Figure11. ESEM micrographs of Low-pressure reacted cement core at the final contact with brine (LP 1-2-OUTLET)


12 SPE 139713

Conclusions

Impact of CO
2
saturated brine on well cements under dynamic (flow through) conditions, appeared to have double-sided
effect on porosity of cement matrix. MIP data revealed porosity reduction for small pore size ranges in LP experiment
whereas porosity increase was detected in HP experiment for medium pore size ranges. Micro-CT scans showed porosity
reduction for medium to large pores sizes.
ESEM/EDS revealed different reaction products at the fracture wall surfaces for HP and LP experiments, whose difference is
in the presence/absence of Fe. Furthermore, outlet section from LP experiment showed secondary fracture network developed
perpendicular to main fracture, which aided dissolution of cement and provides space for secondary calcite precipitation.
Other major observation was the impact of time on overall pore size distribution change. LP experiment conducted for 30
days show more evident porosity reduction for small pore size ranges, while 10 days long HP experiment appears to have
increased porosity for large pore size ranges. In terms of long term behavior of wellbore cements under CCS conditions, it is
possible that cements will undergo both dissolution and precipitation of new minerals. Further research is ongoing to quantify
the change in permeability of cement with acidic brine exposure.


References

Abell A.B., Willis K.L, D.A. Lange, Mercury Intrusion Porosimetry and Image Analysis of Cement Based Materials,Journal of Colloid
and Interface Science, 211, 39-44, 1999.
Bachu S., Bennion B.D., Experimental Assessment of Brine and/or CO
2
Leakage through Well Cements at Reservoir Conditions,
International Journal of Greenhouse Gas Control, 3 (4), 494-501, 2009.
Brandl A., Cutler J., Seholm A., Sansil M., Braun G., BJ Services Co., Cementing Solutions for Corrosive Well Environments, SPE
13228 presented at the CPS/SPE International Oil &Gas Conference and Exhibition, 8-10 June, Beijing, China, 2010.
Duguid A., Radonjic M., Scherer G., Degradation of Well Cements Exposed to Carbonated Brine, 4
th
Annual Conference on Carbon
Capture and Sequestration DOE/NETL, May 2-5, 2005.
Hewlett P., Lea F., Lea`s Cement Chemistry of Cement and Concrete, Fourth Edition, Elsevier, 2004.
Nelson B. E., Guillot D., Well Cementing. Second Edition, Schlumberger, 2006.
Radonjic M., Yalcinkaya T., Willson C.,S., Conductivity of Fractures in Oilwell Cement upon Contact with Sequestered CO
2
,
Proceedings (CD) of the 3
nd
International Conference on Porous Media and its Applications in Science and Engineering, June 20-25,
Italy, 2010.
Ravi K., Bosma M., Gastebled O. Improve the Economics of Oil and Gas Wells by Reducing the Risk of Cement Failure, SPE 84498
presented at the IADC/SPE Drilling Conference, Dallas, Texas, USA, 2002.
Van Gerven T., Cornelis G., Vandoren E., Vandecasteele C., Effects of Carbonation and Leaching on Porosity on Cement-bound waste,
Waste Management 27 (977-985), 2007.

Acknowledgements

We would like to thank Sultan Anbar and Corey Klibert for their help in interpreting the results. We also thank Stefan Bachu
for fruitful discussions. Also, the help from Barry Newton is greatly appreciated in imaging the cement cores at low
resolution. We would like to thank Craft & Hawkins Department of Petroleum Engineering for funding this project. We also
thank Chevron ETC for allowing us to use cement laboratory facilities. Tomography beamline at CAMD acknowledges the
support of the NSF IMR-0216885 (monochromator) and the State of Louisiana through the CAMD operational budget.