victory series™ buccal tubes

MBT™ System Prescription

Upper 1ST Non-Convertible Single - Funneled


Torque Offset L/R .018 in. .022 in.
-14° 10° UL 3 067-879 1 3 067-979 1
-14° 10° UR 3 067-878 2 3 067-978 2

Upper 1ST Convertible Single


Torque Offset L/R .018 in. .022 in.
-14° 10° L 3 068-897 1 3 068-997 1
-14° 10° R 3 068-898 2 3 068-998 2

Upper 1ST Convertible Double Combination - Gingival Headgear


Torque Offset L/R Head Gear .018 in. .022 in.
-14° 10° L .045 068-885 068-985
-14° 10° R .045 068-886 068-986
-14° 10° L .051 068-887 068-987
-14° 10° R .051 068-888 068-988

Upper 1ST Convertible Double Combination - Occlusal Headgear


Torque Offset L/R Head Gear .018 in. .022 in.
-14° 10° L .045 068-893 068-993
-14° 10° R .045 068-894 068-994
-14° 10° L .051 068-895 068-995
-14° 10° R .051 068-896 068-996

Upper 1ST Convertible Triple Combination - Occlusal Headgear


Torque Offset L/R Head Gear .018 in. .022 in.
-14° 10° L .045 068-889 068-989
-14° 10° R .045 068-890 068-990
-14° 10° L .051 068-891 068-991
-14° 10° R .051 068-892 068-992

Upper 2nd Non-Convertible Single - Funneled


Torque Offset L/R .018 in. .022 in.
-19° 8° UL 3 067-873 1 3 067-973 1
-19° 8° UR 3 067-872 2 3 067-972 2

Upper 2ND Non-Convertible Single - Distal Notch


Torque Offset L/R .018 in. .022 in.
-14° 10° L 3 067-857 1 3 067-957 1
-14° 10° R 3 067-858 2 3 067-958 2
Base

Base

APC™ II Adhesive Coated


Appliance System

Note
Appliance is available in APC™ II Adhesive Buccal Tube is available
APC™ II Brackets sold in units of five. 3 Coated Appliance System. Measurements are in millimeters unless otherwise noted. 1 2 3 4 with a bondable base.

24
3Unitek
victory series™ buccal tubes
MBT™ System Prescription

Lower 1ST Non-Convertible Single - Funneled


Torque Offset L/R .018 in. .022 in.
-20° 0° LL 3 067-877 3 3 067-977 3
-20° 0° LR 3 067-876 4 3 067-976 4

Lower 1ST Non-Convertible Single


Torque Offset L/R .018 in. .022 in.
-20° 0° L 3 067-867 3 3 067-967 3
-20° 0° R 3 067-868 4 3 067-968 4

Lower 1ST Convertible Single


Torque Offset L/R .018 in. .022 in.
-20° 0° L 3 067-819 3 3 067-919 3
-20° 0° R 3 067-820 4 3 067-920 4

Lower 1ST Convertible Double


Torque Offset L/R .018 in. .022 in.
-20° 0° L 3 067-861 3 3 067-961 3
-20° 0° R 3 067-860 4 3 067-960 4

Lower 2ND Non-Convertible Single - Distal Notch


Torque Offset L/R .018 in. .022 in.
-10° 0° L 3 067-816 3 3 067-916 3
-10° 0° R 3 067-815 4 3 067-915 4
Base

Base

APC™ II Adhesive Coated


Appliance System

Buccal Tubes for Partially Erupted Second Molars


Upper
Torque Offset L/R .018 in. .022 in.
-14° 0° L 3 066-407 1 3 066-507 1
-14° 0° R 3 066-408 2 3 066-508 2

Lower
Torque Offset L/R .018 in. .022 in.
-10° 0° L 3 066-403 3 3 066-503 3
-10° 0° R 3 066-404 4 3 066-504 4
Base

Base

APC™ II Adhesive Coated


Appliance System

Note
Appliance is available in APC™ II Adhesive Buccal Tube is available
APC™ II Brackets sold in units of five. 3 Coated Appliance System. Measurements are in millimeters unless otherwise noted. 1 2 3 4 with a bondable base.

USA and PR 800.423.4588 25


Canada 800.443.1661
victory series™ 2nd bicuspid tubes
MBT™ System Prescription

No tie-wings to come
into occlusion

No need for ligatures to keep


wire in place
Ligature wire channel
(patent pending)
Chamfered tube
opening to assist in
wire insertion
Metal Injection Molded, Same in-out dimension
including integral hook as Victory Series™
2nd Bicuspid brackets

Micro-Etched base

• Ligation Free – no added sliding friction


There is less chance of • No Tie-Wings – less chance for occlusal interference
occlusal interference • Chamfered Tube Opening to assist in wire insertion
from tubes
• Micro-Etched Base
• Available in APC™ Adhesive Coated Appliance System
• Offset Base Option

3 5 058-801 0 Lower Left 2nd Bicuspid Tube .018 Slot (-17° torque, 2° angulation)
3 5 058-802 0 Lower Right 2nd Bicuspid Tube .018 Slot (-17° torque, 2° angulation)
3 5 058-803 0 Upper Left / Right 2nd Bicuspid Tube .018 Slot (-7° torque, 0° angulation)
3 5 058-901 0 Lower Left 2nd Bicuspid Tube .022 Slot (-17° torque, 2° angulation)
3 5 058-902 0 Lower Right 2nd Bicuspid Tube .022 Slot (-17° torque, 2° angulation)
3 5 058-903 0 Upper Left / Right 2nd Bicuspid Tube .022 Slot (-7° torque, 0° angulation)
APC™ PLUS

Offset Base
APC™ II

Note
Use this prefix to order APC™ II Adhesive Use this prefix to order APC™ PLUS Adhesive Coated
3 Coated Appliance System. 5 Appliance System with color change adhesive.

APC™ II and APC™ PLUS Brackets sold in


units of five.
Measurements are in millimeters unless otherwise noted. Available in APC™ II Adhesive Available in APC™ PLUS Adhesive
Coated Appliance System Coated Appliance System

26
3Unitek
Adhesión de tubos
en las molares

LPPV
Técnica MBT
PRIMERA MOLAR INFERIOR
• En el centro de la corona. El borde
oclusal del tubo debe ser paralelo al
borde lingual de la banda.
• El tubo bucal debe estar paralelo a
la línea intercresta
intercresta.. Altura: 2.5mm.

Posicionamiento
Horizontal

Posicionamiento Axial

Trevisi Hugo. Smartclip Tratamento Ortodontico com sistema de Aparelho Autoligado. Rio de Janeiro : Elsevier, 2007.
•Muchas veces la posición del
tubo se ve comprometida por
las sobremordidas o por la
fuerte inclinación Lingual
debido a la Curva de Wilson.

Posicionamiento vertical

Considerando las bandas, es recomendable


soldar los tubos bucales más para distal,
dándole paralelismo con el borde lingual de
la banda, cementándola de acuerdo con la
anatomía del diente.
Error del posicionamiento horizontal
del tubo bucal en el sentido mesial,
propiciando la rotación del molar.

Así debe ser

Trevisi Hugo. SmartclipTratamento Ortodontico com sistema de Aparelho Autoligado. Rio de Janeiro : Elsevier, 2007.
SEGUNDA MOLAR INFERIOR
• En el centro de la corona , borde oclusal
del tubo paralelo al borde lingual de la
banda.
• El tubo bucal debe estar paralelo a la línea
intercresta.. Altura : 2.5 mm.
intercresta mm.

Trevisi Hugo. SmartclipTratamento Ortodontico com sistema de Aparelho Autoligado. Rio de Janeiro : Elsevier, 2007.
PRIMERA MOLAR SUPERIOR
• En el centro de la corona clínica a la
altura de 3 mm.
• El centro del tubo debe coincidir con
el surco vestibular
vestibular..
• Borde oclusal del tubo paralelo a la
línea vestibular intercresta
intercresta..
SEGUNDA MOLAR SUPERIOR
• En el centro de la corona
clínica a la altura de 2 mm.
• El centro del tubo debe
coincidir con el surco
vestibular..
vestibular
• Borde oclusal del tubo
paralelo a la línea vestibular
intercresta..
intercresta

Trevisi Hugo.SmartclipTratamento Ortodontico com sistema de Aparelho Autoligado. Rio de Janeiro : Elsevier, 2007.

You might also like