You are on page 1of 1

Soft Solution

Machine Foundation
Equipment Base
1 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
A B C D E F G H I J K L M N O P Q
ISBN 81-901030-7-5 Addendum to STQ 1503 NavigationIrrigation Pump Shed- Pump foundation
Machine Foundation - Design - Natural frequency of foundation soil system & amplitude check
References Barkan's formula to determine value of Az Cycles (f)/m v/s amplitude curves RPM in cycles amplitude in mm
Foundation parameters & v n 2.5 mm for 2900 rpm 2900 Az
Length Breadth Depth Concrete Foundation weight Machine m' EUCS Natural Frequency Operating Frequency OF/NF Soil density Amplitude
L B D Density Concrete Soil weight Mass(Total) cu cu*A v n v m h g Po Az
m m m kg/m^3 kg kg kg kg kg/m^2 (cu*A/m)^1/2 Manfacturer's datasheet # kg/cm^3 kgmf mm Method
1.6 1.6 0.35 2500 2240 358.4 990 365.79 7680 19661 7.331362139 2.83 0.386 1.6 2611.1 1.560622 1
m^3 0.896 Pump 395 by equation 1.0855 27788 8.715972306 2.83 0.3247 1.6 2611.1 1.050376 2
Pump 395 [cu=1.13-E/(1-m ^2) /a^.5] Reference Cycles(f )/m v/s amplitude curves mm
cu' determined by both methods Method Vessel 100 Permissible amplitude 2.5
By' Elastic-Area' equation 1 Frame 100 Since' foundation soil system' amplitude is within limits, the foundation is safe in vibration
By 'soil bearing' table consideration 2
Sand Silt General principle
Soil E m m Coefficient A Cu [cu=1.13-E/(1-m ^2) /a^.5] Wherever possible, the operating frequency should be
Kg/cm^2 poisson's ratio poisson's ratio in equation cm^2 Kg/cm^2 lower than the natural frequency of the foundation soil
2000 0.35 0.4 1.13 25600 1.085484 system & preferably within ratio 0.5
L Foundation length m otherwise it should be more than 2
B Foundation breadth m In this case the ratio is 0.386 0.324691
D Foundation depth m
cu Soil elastic uniform compression coefficient for 10 m^2 foundation area 3 to 5 Kg/cm^2 Comparison
A Foundation area m^2 Frequency ratio Amplitude
v n Natural frequency of foundation soil system vibration Permisible Permisible
v m Operating frequency of machine vibration 0.5 2.5
h Operating frequency of machine vibration/Natural frequency of foundation soil system vibration Provided Provided
g Soil density kg/cm^3 0.386012851 1.5606 1.050376
Po Exciting force produced vertically on machine kgmf Resonance shall not occur
Az Amplitude mm Design satisfies both conditions `
m Poisson's ratio
E Young's modulus of elasticity of foundation soil Kg/cm^2
m Combined mass of soil, foundation & machine Kg
ApplicationDeveloper
PEng Suraj 234129686.xls.ms_office 9:33 AM6/15/2014