You are on page 1of 4

PN 10/16 - DN 40...

300
KAT-A 1544
Product characteristics and benefits
Resilient seated in accordance with EN 12334
Face-to-face length acc. to EN 558-1, basic series 48 (DIN 3202, F6)
With flange ends on both sides acc. to EN 1092-2
Low pressure loss due to full bore type (100%)
Double service life due to turnable disk
Integrated limit stops in the disk to protect the seal
No bearing friction due to integrated suspension of disk
Pre-stressed disk closing due to rubber suspension
Incrustation- and corrosion-free rubber lined disk
Quick and easy disassembly of body cover and disk for maintenance
With threaded plug G "
Materials
Body: Ductile cast iron EN-JS 1030 (GGG-40)
Bonnet: Ductile cast iron EN-JS 1030 (GGG-40)
Tests and approvals
Check valve disk: Ductile cast iron EN-JS 1030 (GGG-40) all around EPDM
vulcanized
Final inspection test acc. to EN 12266
(DIN 3230 Part 4)
Bonnet bolts: Stainless steel A2 (DIN EN ISO 3506)
Elastomers approved acc. to W270
Plug: Brass
Accessories
Corrosion protection
Disk lifting device
Inside and outside epoxy coating acc. to GSK guidelines
Note
Versions
For proper installation and safe operation
please follow the installation and operation
instructions:
Standard version as described
With disk lifting device G " (also retrofittable)
Field of Application
KAT-B 1544
Installation in plants
Pressure test acc. to EN 12266 Field of application
Test pressure seat with
water
Test pressure body with
water
Maximum operating
temperature for neutral
liquids
Maximum operating
pressure
PN DN
[bar] [bar] [C] [bar]
17.6 24 50 16 16 40...300
11 15 50 10 10 200...300
Non-Return Valves 1
We reserve the right to make technical changes and use similar or
higher-quality materials. Drawings are non-binding. www.vag-group.com
VAG RETO-STOP Non-Return Valve
Water
Waste water
Drawing
Lifting device
*1: Dimension up to centre of valve
Lifting device (can be replaced by threaded plug)
DN 40...100: 1,5 bar - maximum pressure for lifting
DN 125...200: 0,75 bar - maximum pressure for lifting
DN 250...300: 0,25 bar - maximum pressure for lifting
Technical data
PN 16
300 250 200 150 125 100 80 65 50 40 DN
455 400 340 285 250 220 200 185 165 150 [mm] D
24.5 22 20 19 19 19 19 19 19 19 [mm] b
550 490 400 340 310 225 200 185 160 145 [mm] b1
28 28 23 23 19 19 19 19 19 19 [mm] d2
336 291 237 193 173 138 125 115 95 90 [mm] h1
235 210 185 148 138 113 100 90 82 75 [mm] h2
275 250 225 185 178 152 140 130 120 115 [mm] h3
410 355 295 240 210 180 160 145 125 110 [mm] k
700 600 500 400 350 300 260 240 200 180 [mm] l1
12 12 12 8 8 8 8 4 4 4 No. of holes
3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" [inch] Thread d3
175.50 130.50 81.00 46.00 35.00 21.00 16.00 13.50 10.00 8.00 [kg] Weight approx.
0.190 0.130 0.085 0.050 0.040 0.030 0.015 0.010 0.006 0.005 [m] Volume
approx.
We reserve the right to make technical changes and use similar or
higher-quality materials. Drawings are non-binding. www.vag-group.com 2 Non-Return Valves
Water
Waste water
VAG RETO-STOP Non-Return Valve
Technical data
PN 10
300 250 200 DN
455 400 340 [mm] D
24.5 22 20 [mm] b
550 490 400 [mm] b1
23 23 23 [mm] d2
336 291 237 [mm] h1
235 210 185 [mm] h2
275 250 225 [mm] h3
400 350 295 [mm] k
700 600 500 [mm] l1
12 12 8 No. of holes
3/4" 3/4" 3/4" [inch] Thread d3
175.50 130.50 81.00 [kg] Weight approx.
0.190 0.130 0.085 [m] Volume
approx.
Non-Return Valves 3
We reserve the right to make technical changes and use similar or
higher-quality materials. Drawings are non-binding. www.vag-group.com
VAG RETO-STOP Non-Return Valve
Water
Waste water
Further information
Flow resistance coefficient
x: Flow velocity [m/s]
y: Flow resistance coefficient
A: Operation limit
We reserve the right to make technical changes and use similar or
higher-quality materials. Drawings are non-binding. www.vag-group.com 4 Non-Return Valves