Power Line Carrier Equipment: Series ETL600
Compatibility Requirements for ETL600



Contents

1 Purpose of document 1
2 General 1
3 Release and Version Management 2
4 Compatibility rules 2
5 ETL600 Releases 3
6 Release notes 7
6.1 Release 1.0.2 7
6.2 Release 1.0.3 7
6.3 Release 1.0.4 7
6.4 Release 2.0.0 7
6.5 Release 2.1.0 7
6.6 Release 2.1.1 7





1 Purpose of document
This document describes the compatibility requirements for the ETL600 system.
2 General
The ETL600 system consists of
1. Hardware, consisting of a number of modules;
2. Firmware, residing on some of the modules and making the processors on these modules
execute various functions such as modulation, digital filtering etc.;
3. PC based software, implementing the user interface for configuration, testing and monitoring
of the equipment.


Revision: Language: Page:
H EN 2/7
1KHW01490-EN

3 Release and Version Management
ABB continuously enhances the ETL600 system by upgrading hardware, firmware and software.
An ETL600 system release, identified by a release number, is a product of defined functionality
comprising hardware modules, firmware and software.
Firmware and software are identified with version numbers of the form NN.nn., e.g. 5.08 (leading
zeros may be omitted).
Releases are identified by release numbers of the form RR.r.d, e.g. 3.1.0 (leading zeros may be
omitted). RR indicates the main release, r the sub-release and d the update version inside a sub-
release.
Hardware modules are identified with type codes consisting of 4 characters like P7LC, G4AI or
P4LT. Sometimes, a fifth character - the revision index - is appended to identify an upgraded
version of a module. Example: P4LTa is an upgraded version of P4LT; P4LTb would be an
upgraded version of P4LTa and so on.

Note: The information content of type codes in case of modules containing firmware
depends on the possibility to download firmware from HMI600 into the module:
If for a component firmware download is not possible, the type code of that
component identifies the hardware including the firmware version.
Example: Microcontroller on P4LT/P4LU
If for a module firmware download is possible, the type code of that module
identifies the hardware excluding the firmware version. The download files
for the firmware of such modules are included on the HMI600 Software &
Documentation CD.
Example: O4LE
4 Compatibility rules
Rule Nr. 1:
The modules of an ETL600 terminal and the firmware on these modules must belong to the
same release as given by Table 1.
If an equipment contains modules of different releases, it will generally not work correctly.
Rule Nr. 2:
The two ETL600 terminals of a link must belong to the same release.
If this rule is violated, the EOC of the link will generally not work correctly. Corresponding
warning messages will be generated by HMI600.
Rule Nr. 3:
The HMI600 software must have full or restricted compatibility to the ETL600 terminals being
connected to.
The term "restricted compatibility" is used when the functionality has been changed between
releases as long as the HMI600 program can handle these changes in a reasonable way.
Revision: Language: Page:
H EN 3/7
1KHW01490-EN

5 ETL600 Releases
Release Compatible hardware, firmware and software
ETL600
Rel. 1.0.1
- Software HMI600 version 1.22 (for PC with Windows 2000 or XP),
- Software SVR600 version 1.00 or higher (for PC with Windows 2000 or XP),
- Firmware ETL600 version 1.28 on module P4LT/P4LTa or P4LU/P4LUa,
- Microcontroller firmware version 1.10 or higher on module P4LT/P4LTa or P4LU/P4LUa,
- Firmware O4LE version 2.14 or higher on module O4LE/O4LEa,
- Firmware G4AI version 3.00 or higher on module G4AI/G4AIa,
- ETL640/ETL680:
Power subrack P7LA with hardware modules P1LA, B5LA or B5LC, E5TX, P3LE/P3LEa,
P3LG,
- Channel subrack P7LC with hardware modules B4LE, P4LT/P4LTa or P4LU/P4LUa, P4RX,
earth rail R9AL and optional hardware modules O4LE/O4LEa, G4AI/G4AIa, R1BC,
- External cables V9OW/V9OU/V9OV/V9OT (for P4LT/P4LTa or P4LU/P4LUa), V9MR (for
R1BC), V9OS (for O4LE/O4LEa), and V9OF (for G4AI/G4AIa),
- Optional remote inquiry set R7AP,
- Service telephone Q8AB,
- Circuit breaker B9AS.
ETL600
Rel. 1.0.2
- Software HMI600 version 1.24 or higher (for PC with Windows 2000 or XP),
- Software SVR600 version 1.00 or higher (for PC with Windows 2000 or XP),
- Firmware ETL600 version 1.31 or higher on module P4LT/P4LTa or P4LU/P4LUa,
- Microcontroller firmware version 1.10 or higher on module P4LT/P4LTa or P4LU/P4LUa,
- Firmware O4LE version 2.14 or higher on module O4LE/O4LEa,
- Firmware G4AI version 3.00 or higher on module G4AI/G4AIa,
- ETL640/ETL680:
Power subrack P7LA with hardware modules P1LA, B5LA or B5LC, E5TX, P3LE/P3LEa,
P3LG,
- Channel subrack P7LC with hardware modules B4LE, P4LT/P4LTa or P4LU/P4LUa, P4RX,
earth rail R9AL and optional hardware modules O4LE/O4LEa, G4AI/G4AIa, R1BC,
- External cables V9OW/V9OU/V9OV/V9OT (for P4LT/P4LTa or P4LU/P4LUa), V9MR (for
R1BC), V9OS (for O4LE/O4LEa), and V9OF (for G4AI/G4AIa),
- Optional remote inquiry set R7AP,
- Service telephone Q8AB,
- Circuit breaker B9AS.
Revision: Language: Page:
H EN 4/7
1KHW01490-EN

Release Compatible hardware, firmware and software
ETL600
Rel. 1.0.3
- Software HMI600 version 1.26 or higher (for PC with Windows 2000 or XP),
- Software SVR600 version 1.00 or higher (for PC with Windows 2000 or XP),
- Firmware ETL600 version 1.34 on module P4LT/P4LTa or P4LU/P4LUa,
- Microcontroller firmware version 1.10 or higher on module P4LT/P4LTa or P4LU/P4LUa,
- Firmware O4LE version 2.14 or higher on module O4LE/O4LEa,
- Firmware G4AI version 3.00 or higher on module G4AI/G4AIa,
- ETL640/ETL680:
Power subrack P7LA with hardware modules P1LA, B5LA or B5LC, E5TX, P3LE/P3LEa,
P3LG,
- Channel subrack P7LC with hardware modules B4LE, P4LT/P4LTa or P4LU/P4LUa, P4RX,
earth rail R9AL and optional hardware modules O4LE/O4LEa, G4AI/G4AIa, R1BC,
- External cables V9OW/V9OU/V9OV/V9OT (for P4LT/P4LTa or P4LU/P4LUa), V9MR (for
R1BC), V9OS (for O4LE/O4LEa), and V9OF (for G4AI/G4AIa),
- Optional remote inquiry set R7AP,
- Service telephone Q8AB,
- Circuit breaker B9AS.
ETL600
Rel. 1.0.4
- Software HMI600 version 1.26 or higher (for PC with Windows 2000 or XP),
- Software SVR600 version 1.00 or higher (for PC with Windows 2000 or XP),
- Firmware ETL600 version 1.36 or higher on module P4LT/P4LTa or P4LU/P4LUa,
- Microcontroller firmware version 1.10 or higher on module P4LT/P4LTa or P4LU/P4LUa,
- Firmware O4LE version 2.14 or higher on module O4LE/O4LEa,
- Firmware G4AI version 3.00 or higher on module G4AI/G4AIa,
- ETL640/ETL680:
Power subrack P7LA with hardware modules P1LA, B5LA or B5LC, E5TX, P3LE/P3LEa,
P3LG,
- Channel subrack P7LC with hardware modules B4LE, P4LT/P4LTa or P4LU/P4LUa, P4RX,
earth rail R9AL and optional hardware modules O4LE/O4LEa, G4AI/G4AIa, R1BC,
- External cables V9OW/V9OU/V9OV/V9OT (for P4LT/P4LTa or P4LU/P4LUa), V9MR (for
R1BC), V9OS (for O4LE/O4LEa), and V9OF (for G4AI/G4AIa),
- Optional remote inquiry set R7AP,
- Service telephone Q8AB,
- Circuit breaker B9AS.
Revision: Language: Page:
H EN 5/7
1KHW01490-EN

Release Compatible hardware, firmware and software
ETL600
Rel. 2.0.0
- Software HMI600 version 1.41 or higher (for PC with Windows 2000 or XP),
- Software SVR600 version 1.00 or higher (for PC with Windows 2000 or XP),
- Firmware ETL600 version 1.47 or higher on module P4LT/P4LTa or P4LU/P4LUa,
- Microcontroller firmware version 1.10 or higher on module P4LT/P4LTa or P4LU/P4LUa,
- Firmware O4LE version 2.14 or higher on module O4LE/O4LEa,
- Firmware G4AI version 3.00 or higher on module G4AI/G4AIa,
- Firmware R1LA version 1.13 on module R1LA,
- ABB-ETL-MIB version 1,
- ETL640/ETL680:
Power subrack P7LA with hardware modules P1LA, B5LA or B5LC, E5TX, P3LE/P3LEa,
P3LG,
- Channel subrack P7LC with hardware modules B4LE, P4LT/P4LTa or P4LU/P4LUa
1)
,
R1LA, P4RX, earth rail R9AL and optional hardware modules O4LE/O4LEa, G4AI/G4AIa,
R1BC,
- External cables V9OW/V9OU/V9OV/V9OT/V9OX/V9OY (for P4LT/P4LTa or P4LU/P4LUa),
V9OH/V9OZ (for P4LUa), V9MR (for R1BC), V9OS (for O4LE/O4LEa), and V9OF (for
G4AI/G4AIa),
- Optional remote inquiry set R7AP,
- Service telephone Q8AB,
- Circuit breaker B9AS.

1)
Note:
The module R1LA is only compatible with P4LUa, not with P4LU and P4LT/P4LTa.
ETL600
Rel. 2.1.0
- Software HMI600 version 2.08 or higher (for PC with Windows 2000 or XP),
- Software SVR600 version 1.00 or higher (for PC with Windows 2000 or XP),
- Firmware ETL600 version 2.06 or higher on module P4LT/P4LTa or P4LU/P4LUa,
- Microcontroller firmware version 1.10 or higher on module P4LT/P4LTa or P4LU/P4LUa,
- Firmware O4LE version 2.14 or higher on module O4LE/O4LEa,
- Firmware G4AI version 3.12 or higher on module G4AI/G4AIa,
- Firmware R1LA version 1.13 on module R1LA,
- ABB-ETL-MIB version 1,
- ETL640/ETL680:
Power subrack P7LA with hardware modules P1LA, B5LA or B5LC, E5TX, P3LE/P3LEa,
P3LG,
- Channel subrack P7LC with hardware modules B4LE, P4LT/P4LTa or P4LU/P4LUa
1)
,
R1LA, P4RX, earth rail R9AL and optional hardware modules O4LE/O4LEa, G4AI/G4AIa,
R1BC,
- External cables V9OW/V9OU/V9OV/V9OT/V9OX/V9OY (for P4LT/P4LTa or P4LU/P4LUa),
V9OH/V9OZ (for P4LUa), V9MR (for R1BC), V9OS (for O4LE/O4LEa), and V9OF (for
G4AI/G4AIa),
- Optional remote inquiry set R7AP,
- Service telephone Q8AB,
- Circuit breaker B9AS.

1)
Note:
The module R1LA is only compatible with P4LUa, not with P4LU and P4LT/P4LTa.
Revision: Language: Page:
H EN 6/7
1KHW01490-EN

Release Compatible hardware, firmware and software
ETL600
Rel. 2.1.1
- Software HMI600 version 2.10 or higher (for PC with Windows 2000 or XP),
- Software SVR600 version 1.00 or higher (for PC with Windows 2000 or XP),
- Firmware ETL600 version 2.07 or higher on module P4LT/P4LTa or P4LU/P4LUa,
- Microcontroller firmware version 1.10 or higher on module P4LT/P4LTa or P4LU/P4LUa,
- Firmware O4LE version 2.14 or higher on module O4LE/O4LEa,
- Firmware G4AI version 3.12 or higher on module G4AI/G4AIa,
- Firmware R1LA version 1.13 on module R1LA,
- ABB-ETL-MIB version 1,
- ETL640/ETL680:
Power subrack P7LA with hardware modules P1LA, B5LA or B5LC, E5TX, P3LE/P3LEa,
P3LG,
- Channel subrack P7LC with hardware modules B4LE, P4LT/P4LTa or P4LU/P4LUa
1)
,
R1LA, P4RX, earth rail R9AL and optional hardware modules O4LE/O4LEa, G4AI/G4AIa,
R1BC,
- External cables V9OW/V9OU/V9OV/V9OT/V9OX/V9OY (for P4LT/P4LTa or P4LU/P4LUa),
V9OH/V9OZ (for P4LUa), V9MR (for R1BC), V9OS (for O4LE/O4LEa), and V9OF (for
G4AI/G4AIa),
- Optional remote inquiry set R7AP,
- Service telephone Q8AB,
- Circuit breaker B9AS.

1)
Note:
The module R1LA is only compatible with P4LUa, not with P4LU and P4LT/P4LTa.
Table 1
Revision: Language: Page:
H EN 7/7
1KHW01490-EN

6 Release notes
6.1 Release 1.0.2
Changes relative to Release 1.0.1:
Software HMI600 Version 1.24 and Firmware ETL600 Version 1.31:
Various improvements of MOD600.
Mail vom 17.2.06 16:42 von Christian Leeb an Michael Strittmatter und Hans Benninger:
Hermann Spiess mchte, dass die Information betreffend der MOD600 Verbesserungen nicht in den Release Notes erscheint.
Hybrid P3LEa:
Correction of anomaly concerning the socket RF line monitor.
6.2 Release 1.0.3
Changes relative to Release 1.0.2:
Minor MOD600 performance improvements.
6.3 Release 1.0.4
Release 1.0.4 includes the following improvements relative to Release 1.0.3:
Support of actual and previous versions of the Dummy Load P3LK for RF-loopback operation
(testing mode).
Performance optimization of NSD600 for blocking simultaneous with data transmission at low
temperatures.
An upgrade at the next occasion from a previous release is recommended but not mandatory.
6.4 Release 2.0.0
Additions relative to Release 1.0:
NSD600 in 2 kHz APLC channel
LAN interface
G.703.1 interface
V.11 transit operation
ETL640 (40 W output power):
Tx filters with 8 kHz bandwidth for center frequencies 28 40 kHz (steps 0.5 kHz) added
6.5 Release 2.1.0
Release 2.1.0 includes the following improvements relative to Release 2.0.0:
ETL680 (80 W output power):
Tx filters with 8 kHz bandwidth for center frequencies 28 40 kHz (steps 0.5 kHz) added
Anomaly eliminated (see 1KHW001497 Anomaly List for ETL600):
Time-limited persistent commands of NSD600 in 2 kHz APLC channel
An upgrade at the next occasion from a previous release is recommended but not mandatory.
6.6 Release 2.1.1
Release 2.1.1 includes the following improvements relative to Release 2.1.0:
ETL680 (80 W output power):
Tx filters with 4 kHz bandwidth for center frequencies 40..500 kHz (steps 0.5 kHz) added
Anomaly eliminated (see 1KHW001497 Anomaly List for ETL600):
Configuration file incompatibility
An upgrade at the next occasion from a previous release is recommended but not mandatory.