You are on page 1of 55

AccuMark Advanced Edition

Software Release Notice


8.0.8


1. Release Contents ................................................................................................................3
2. System Requirements .........................................................................................................4
3. Operating System Guidelines..............................................................................................6
4. Software Installation Instructions.........................................................................................7
5. Hardware & Software Security ..........................................................................................10
6. Starting AccuMark Advanced Edition components ...........................................................11
7. Support/Problem Reporting Procedure .............................................................................11
8. Using Standard AccuMark Advanced Edition Test Data for Test......................................11
9. AccuMark Supported Plotters and Networks.....................................................................13
10. Software Status Update.....................................................................................................14
AccuMark 8.0.8.............................................................................................................................14
AccuMark 8.0.8.............................................................................................................................14
Pattern Design 8.0.8....................................................................................................................14
AccuMark 8.0.7.............................................................................................................................14
AccuMark 8.0.7.............................................................................................................................14
Pattern Design 8.0.7....................................................................................................................16
AccuMark 8.0.6.............................................................................................................................20
AccuMark 8.0.6.............................................................................................................................20
Pattern Design 8.0.6.....................................................................................................................20
AccuMark 8.0.5.............................................................................................................................21
AccuMark 8.0.5.............................................................................................................................21
Pattern Design 8.0.5.....................................................................................................................24
AccuMark 8.0.4.............................................................................................................................27
AccuMark 8.0.4.............................................................................................................................27
Pattern Design 8.0.4.....................................................................................................................28
AccuMark 8.0.3.............................................................................................................................28
AccuMark 8.0.3.............................................................................................................................28
Pattern Design 8.0.3.....................................................................................................................31
AccuMark 8.0.2.............................................................................................................................34
AccuMark 8.0.2.............................................................................................................................34
Pattern Design 8.0.2.....................................................................................................................37
AccuMark 8.0.1.............................................................................................................................42
AccuMark 8.0.1.............................................................................................................................42
Pattern Design 8.0.1.....................................................................................................................44
AccuMark 8.0.0.............................................................................................................................47















Page 1 of 55






Page 2 of 55

AccuMark Advanced Edition
Software Release Notice
8.0.8

1. Release Contents

This release contains

One CDROM

One paper document identified as:

Installation document for the AccuMark Advanced Edition Release 8.0.8

Electronic documents: AccuMark AE Software Release Notice for 8.0.8, AccuMark
Configuration Notes and AccuMark AE Whats New

For New Installations and possibly for Upgrades (depending on the version)
One software security license file
One hardware security dongle



The CD contains the full set of executable files and the installation program for the AccuMark
Advanced Edition System and are marked as:

AccuMark Advanced Edition
Release 8.0.8
September 2004

Page 3 of 55

2. System Requirements

General Requirements
Adjust the power switch on the back of the computer in accordance to the local
power settings (either 115 VAC or 220 VAC).
All systems require a mouse or compatible pointing device and a standard keyboard.
A CD-ROM drive is needed for installing software.
Internet Explorer 6.0 or higher (IE 6 SP1 is available on the Supplemental
Components CD).
You must be logged on as an administrator to properly install the software.
System settings for Colors must be set higher than 256 Colors.
Refer to the Release Notes for compatible optional equipment (plotters, digitizers,
networks, etc.).
Microsoft Manager Console (MMC) is needed for AccuMark Backups.
Install Adobe Acrobat Reader to view the documentation.
The use of disk compression utilities is not recommended.
Installation on AccuMark Professional or Advanced edition runs a security permission
program at the end of the install that sets administrator privileges for the Users group
to AccuMark data (storage areas) and program directories. Setting Permissions
provides the ability for non-administrator users to access Gerber data and
applications. For complete details, see Setting Permissions.

Windows XP Professional Requirements
Hardware Minimum Good Best
Processor Type Pentium II Pentium II Pentium III or IV
Processor Speed 266 MHz 333 MHz 1 GHz or higher
Video Adapter /
Monitor
Super VGA video
adapter
Super VGA video
adapter
Ultra VGA 1280 X
1024
Hard Disk Capacity 230 MB free space 230 MB free space 230 MB free space
Memory 128 MB 128 MB 256 MB
Service Packs SP 1 + critical
updates
SP 1 + critical
updates
SP 2 + critical
updates
In order for you to effectively use AccuMark software, the Best requirements in the above table
are recommended.
Additional Requirements
Microsoft Critical Updates which can be found by clicking the Start, All Programs,
Windows Update on your XP System. Note that this requires an Internet connection.
Turn off Fast User Switching when creating new users. If this is turned on, it will
result in configuration errors.
Turn off Simple File Sharing through the Tools, Folder Options in Windows Explorer
or Control Panel.

Notes:
If you are trying to install the software as a non-administrator, you may be prompted to Install
Program as Other User. DO NOT continue, even if you know the password to an administrator
account. The software must be installed as an administrator (the installation will check at the
beginning of the installation for such privileges).

Page 4 of 55



Windows 2000 Requirements
Hardware Minimum Good Best
Processor Type Pentium Pentium II Pentium III or IV
Processor Speed 266 MHz 333 MHz 1 GHz or higher
Video Adapter / Monitor VGA or higher
resolution display
Super VGA video
adapter
Ultra VGA 1280 X
1024
Hard Disk Capacity 230 MB free space 230 MB free space 230 MB free space
Memory 128 MB 128 MB 256 MB or 512 MB
Service Packs SP 4 SP 4 SP 4 & Critical
Updates
In order for you to effectively use AccuMark software, the Best requirements in the above table
are recommended.
Additional Requirements
Microsoft Critical Updates which can be found by clicking the Tools, Windows Update
from the Internet Explorer. Note that this requires an Internet connection.

Notes:
It is always best to use the latest service packs and critical updates


Windows NT Requirements
Hardware Minimum Good Best
Processor Type Pentium Pentium II Pentium III or IV
Processor Speed 266 MHz 333 MHz 1 GHz or higher
Video Adapter / Monitor VGA or higher
resolution display
Super VGA video
adapter
Ultra VGA 1280 X
1024
Hard Disk Capacity 230 MB free space 230 MB free space 230 MB free space
Memory 64 MB 128 MB 256 MB or 512 MB
Service Packs SP 6 SP 6 SP 6a
In order for you to effectively use AccuMark software, the Best requirements in the above table
are recommended.
Additional Requirements
Microsoft Management Console (MMC) available on the AccuMark Family CD-ROM
in the MMC directory.
Microsoft Data Access Components (MDAC). Version 2.7 SP1 is available from the
Supplemental Components CD.
Installation of Adobe Acrobat Reader prior to installing AccuMark V8 software.

Notes:
It is always best to use the latest service packs and critical updates

Page 5 of 55

Unsupported Operating Systems
The following operating systems are not supported for AccuMark Family software. While you may
be able to install this software, it is possible you will experience technical problems.
Windows ME
Windows XP Home Edition
Windows 9x

3. Operating System Guidelines
3.1 Windows XP, 2000 and NT Users
There are many permutations and combinations of user permissions that an
administrator can implement. The AccuMark installation does not override security
permissions. Since an administrator can create registry keys at most levels, it is required
that a user with administrator privileges perform all setups.

You may not be fully able to uninstall an application under Windows if you are not logged
on with the same privileges that you had when you installed the application. For further
details please refer to the Configuration Notes for Windows.

3.2 Windows Service Packs
AccuMark version 8.0.5 and later installations require that you have the latest windows
service packs installed before proceeding with the installation of AccuMark software.
Before starting the installation use the Test for Minimum Requirements to check your
system. Refer to the charts in section 2 above for the required service pack version for
each of the suitable operating systems.

If you run the installation of AccuMark version 8.0.5 or later and have a previous version
of AccuMark V8 software, the installation will first remove the previous version. If your
system does not meet the minimum operating system requirements, you will not be able
to proceed with the installation. You may return to a previous version by re-installing that
software.

3.3 Installing the Windows XP Professional Updates
Windows XP Professional critical updates can be downloaded from Microsofts website.
From the Start Menu, select All Programs followed by Windows Update. Note this
requires an Internet connection.


3.4 Installing the Windows 2000 Service Pack
The Microsoft Permissions/Copyright Group does not provide special permission to
redistribute Service Packs for Windows 2000. It is required to install Windows 2000
Service Pack 4 on all Windows 2000 systems.
Windows 2000 Service Packs provide the latest updates to the Windows 2000 family of
operating systems. These updates are a collection of fixes in various areas and are
cumulative (for example, Service Pack 4 will have items from Service Pack 3 and earlier).
To get the latest service packs and update, use the Tools, Windows Update from the
Internet Explorer, and select the Scan for Updates link. Note that this requires an internet
connection.

3.5 Installing the Windows NT 4.0, Service Pack
If you have Windows NT 4.0, it is highly recommended that you install Microsoft Service
Pack 6a on your system.


Page 6 of 55

To install the Service Pack, visit the Microsoft Windows NT Server Web site at
http://www.microsoft.com/windows/servicepacks. Before downloading, determine the
type of encryption installed on the system. This information can be found at the same
website.

On a clean NT 4.0 with service pack 6 install Adobe Acrobat Reader before installing
AccuMark.
On NT, if problems are encountered when installing the software, close the Web/Install
window and continue.
4. Software Installation Instructions
The Installation procedure for AccuMark Advanced Edition Release 8.0.8 will
automatically install the appropriate software on the AccuMark Advanced Edition system.
This includes:
Pattern Design
ASTM Pattern Conversion Wizard
DXF Converter (DXF Import)
Lconvert (Lectra to AccuMark)

Additional applications such as Winplot are included with the professional software
license but must be installed separately.

Important!
Clock: Date and Time
It is extremely important to check the date and time BEFORE proceeding with the
installation of the software. Turning back the clock once the software has been installed
and running is strongly discouraged!

4.1 Installing the AccuMark Advanced Edition Release 8.0.8
IMPORTANT: Close any open programs before installing the software.

No Previous Version of AccuMark installed
Simply follow the Steps to Install below.

Previous Version of AccuMark 8.0 installed
If a previous version of AccuMark 8.0 is installed, it will automatically be uninstalled prior
to installing this software. A dialog box is displayed informing the user when the
installation is started.

Previous Version of AccuMark 7.6.x installed
If you have AccuMark version 7 software on your system, you do not need to uninstall it
first. You can install version V8 software in addition to version 7. Follow Steps to Install
below.

To install multiple AccuMark Versions
Multiple versions of AccuMark software may be installed on the same system provided
you install in this sequence:
Install AccuMark 7.6.x, AccuMark MicroMark Explorer 2.0.x; or Install MicroMark
1.4.x, AccuMark MicroMark Explorer 2.0.x
Install PDS 2.0.x
Install MS2000 1.2.x

Page 7 of 55

Install AccuMark V8

Page 8 of 55


Important! If you uninstall AccuMark V7:
When AccuMark V7 and V8 are installed on the same PC, AccuMark V8 must be
reinstalled if AccuMark V7 is uninstalled. Reinstalling V8 will restore the software
environment so that V8 will continue to run properly.

Important! If you have MicroMark 1.4.x installed:
AccuMark V8.0.5 and earlier versions would overwrite various MicroMark .bin files. The
installation has been updated to not overwrite these files in the \ADS and subdirectories.
If you are installing over MicroMark software it is recommended to make copies of your
.bin files before proceeding with this installation. You can then copy the saved files back
to keep your previous MicroMark settings.

Steps to Install
1. Insert the CD of AccuMark Advanced release into the CDROM drive.
2. On most Windows systems setup will automatically start the installation when the CD
is loaded. If AutoPlay is not enabled on your system,
a) From the Start menu, select Run
b) Type e:\setup (where e: is the letter of your CDROM drive)
c) Select OK

3. Check your system requirements by running the Test for minimum requirements on
the start page. Install any system updates as indicated by the test results.
4. Install Acrobat Reader and view the documentation.
5. Click Install AccuMark Advanced Edition.
6. You may select an alternate destination directory when prompted, or simply accept
the default folder.
7. For a standard installation select Typical. Selecting the Typical Setup type will
assure all required applications and files are installed.
8. You may be prompted to choose to overwrite only the Sample storage areas that are
installed with PE installations. Selecting Yes will remove any existing data in those
storage areas only, and re-copy the sample data. Selecting No will leave the current
data intact. The sample storage areas are GTBASICS and DATA70. Overwriting
these storage areas will not affect any other user created storage areas.
9. If you desire to use the Send To option available in the AccuMark Explorer, you must
select on of the Email Options when prompted. This option will work with the Email
system that is installed on your PC. For instance, if you are using Microsoft Outlook,
select Microsoft Mail/Lotus cc:Mail option.
10. The installation will also launch a subsequent install for the Problem Report Utility for
new installations or if updates have been made to these applications. The Problem
Report Utility provides the ability to send electronic reports to GT.
11. The installation will also launch a subsequent install for the new GTLM Security for
new installations or if updates have been made to these applications. GTLM installs
Sentinel drivers and services that will be used for the V8 keys and license files.
12. The installation will also launch a subsequent install for the Lconvert application.
13. On new installations a license agreement is displayed. Read and accept the terms of
the agreement.
14. An informational dialog box will display instructing the user how to install your license

Page 9 of 55

file. This is only needed for New installations or purchased Upgrades (for example,
8.0 to 8.1). Free updates do not require re-installing your license file (for example,
8.0.2 to 8.0.3). Refer to section 5 Software Security for details.
15. The security permission program is started at the end of the install to set
administrator privileges for the Users group to AccuMark data (storage areas) and
program directories. Setting Permissions provides the ability for non-administrator
users to access Gerber data and applications.
16. You can optionally view the Readme document at the end of the installation which
will open the Release Notes using Adobe Acrobat Reader.
17. When the installation has completed, select Yes to restart your computer, if
prompted.
4.2 License Agreement
When you run the AccuMark system for the first time after installing the software an
approval of the licensing agreement is necessary. Once the affirmative response has
been entered, the licensing agreement will not display again

4.3 Directory Structure
The installation creates the C:\USERROOT directory structure, which contains the data,
required by the system. The program files are located in the subdirectories under
c:\program files\Gerber Technology.


5. Hardware & Software Security
AccuMark Products use a combination of software based security technology and a
hardware security key (dongle) to license and protect the software. Version 8 software
will not run on a system that does not have the new key and license file.

5.1 Hardware Security attaching the key
Attach the security key (dongle) to the parallel port of the PC or workstation. A Security
License File is unique to each security key (dongle). The combination of key and license
file will allow activation of the AccuMark Family software as stated in the software
subscription contract.

5.2 Retrieving your License File
The security license file name is a combination of the product and key number with the
file extension of .lic, for example accumark111.lic. Copy the appropriate license file onto
the system with the matching key number.

If the license file was received through Email, save the attached file to a location on your
hard drive or on the desktop (for example, c:\program files\common files\gerber
technology\gt license manager). If the license file was received on a floppy, it may be
installed directly from the floppy and/or copied to your hard drive.

5.3 Software Security License Install License program
The AccuMark Family Product CD installs an Install License program that easily copies
your license file into the proper destination for use by AccuMark applications. Use the
Install License icon on the Desktop, or from the LaunchPad on the "AccuMark
Explorer/Utilities" page, or use the AccuMark V8 folder, select "AccuMark
Explorer/Utilities" and then "Install License".

A dialog box displays allowing you to choose the Product and source location for the

Page 10 of 55

license file (use the ellipses () button to locate your license file). Note the key number
on the right had side of the dialog box and match to the right license file. Run the
program once for each Product. The program, by default, looks for files of type .lic . It will
prompt you to overwrite the existing license file if one already exists

6. Starting AccuMark Advanced Edition components

Start the AccuMark applications from the following locations:

1. From the Start menu select the Gerber LaunchPad icon. The AccuMark Advanced
Edition LaunchPad menu contains the selections for Pattern Input, Pattern Design,
Order Entry, Marker Making, AM-Explorer, Utilities, Hardware Configuration and plot
output. Select one of the program icons to start the application.

2. On the desktop you will see a Gerber LaunchPad icon. Double click on the G
icon. The AccuMark LaunchPad menu contains the selections for Pattern Input,
Pattern Design, Order Entry, Marker Making, AM-Explorer, Utilities, Hardware
Configuration and plot output. Select one of the program icons to start the
application.

3. In addition, from the Start menu, applications can be accessed from the associated
program folders. Shortcuts to the desktop can also be created from this location.


7. Support/Problem Reporting Procedure

Customer Service support hours are from 8am until 7pm Eastern Standard Time. If you have a
question or encounter a problem, please contact GTs Customer Service Department. Our toll
free number 1-800-321-2448 can be called during support hours from anywhere in North
America.
International customers, please contact your local Gerber Office or Agent and Distributor for
assistance.

8. Using Standard AccuMark Advanced Edition Test Data for Test

This section describes the procedures for checking the AccuMark Professional Edition
system by using the standard version 7 test data which is installed in the DATA70 and
GTBASICS storage areas. The DATA70 and GTBASICS storage areas will automatically
be installed during a typical installation if no other storage area by that name exists, and
may be optionally overwritten if the storage area already exists.

It is recommended for users to create their own storage areas to contain their data (do
not use storage area name DATA70). These areas should only be used for training or
testing purposes.

8.1. DISPLAY A PIECE

From the LaunchPad menu select AccuMark Explorer

1. Select LADIES-BLOUSE-BK and open it in Pattern Design.

Page 11 of 55

2. Bring piece into the work area and select View/Grades sizes.
3. Press right mouse button or cancel functions.
4. Exit Pattern Design.

8.2. ORDER A MARKER

From the LaunchPad menu select the Marker Creation, Editors page. Click on the Order
Icon or, open AccuMark Explorer.

1. From the Order form select File Open and select TESTMARKER.
2. Press the green arrow key or select File - PROCESS.
3. The message "Processing order: TESTMARKER" should now display on the screen.
When the order has finished processing, the message "Processed Successfully
should display.
8.3. RETRIEVING A MARKER

From the LaunchPad menu select the Marker Creation, Editors page and
click on the Marker Making Icon or, open AccuMark Explorer.

1. From the File Menu select Open.
2. Two marker names will be displayed:
TESTMARKER an unmade marker (created by ORDER A MARKER above)
LADIES-BLOUSE a made marker
3. To select a marker from the list, highlight the marker name using the mouse, and
select Open.


8.4. SELECTING AND SLIDING PIECES IN MARKER MAKING

1. Move the mouse cursor over the numbers below the pieces in the icon menu. The
piece count will highlight and the associated piece name and size will display in the
status bar.
2. Select using the left mouse button.
3. When a piece is selected, the perimeter will become dotted and the piece will attach
to the mouse cursor.
4. To slide the piece into the marker, press the left mouse button and draw a vector in
the direction desired. Release the mouse button.
5. The piece will move in the direction of the slide vector. If the piece fits into the area
where it was slid, it will place.

8.5. PLOTTING A MARKER
Use the Hardware Configuration icon to configure a plotter. Then from the LaunchPad
menu select the Plotting and Cutting page or, open AccuMark Explorer.

From the LaunchPad menu select the Plotting page or, open AccuMark Explorer.

1. From the LaunchPad options select the MARKER PLOT icon.
2. Select the location as Data70. In the marker name field select LADIES-BLOUSE.
3. From AccuMark Explorer, right-click on the marker LADIES-BLOUSE and select
Send To Plotter.
4. Press the green arrow or select PROCESS ALL from the File drop down menu.

Page 12 of 55

5. If the plotter is online and properly configured it will begin plotting.


9. AccuMark Supported Plotters and Networks

9.1. Supported Plotters

The following plotters are now supported on AccuMark system:


AccuJet 510/520
Accuplot 100
Accuplot 300/310/320
Accuplot 350
Accuplot 700
Accuplot 700-CXS
Accuplot 700-VPS
APC-L800 (Zund-L800)
APC-XL800 (Zund-XL800)
Gerber Infinity I
Gerber Infinity II
HP DesignJet 600
HP DesignJet 700
HP Windows device
driver(hpwdev)
HP7440
HP7475A
HP7595
Lectra FlyPen(Lectra)
MicroJet 20/30


MicroJet 30W
MicroJet 60/85
MicroJet 60W/85W
Misomex
SM-1000-1.5
SM-1000-2.0
SM-1000-2.5
SM-1000-3.0x2
SP-100
SP-150
SP-200
WildTA10
WildTA40
WildTA400
WildTA500
Windows device driver(windev)




9.2. Supported Networks
The following is a list of compatible networks for the AccuMark system:

Windows NT Windows 2000 Windows XP
Client for Microsoft
Networks (for peer to
peer or client/server)

Client for Microsoft
Networks (for peer to
peer or client/server) *

Client for Microsoft
Networks (for peer
to peer or
client/server)
Novell 3.1/4.11
Microsoft Client
Service for
Netware (CSNW)
Novell 3.1/4.11
Microsoft Client
Service for Netware
(CSNW)
Novell 3.1/4.11
Microsoft Client
Service for Netware
(CSNW)

Lantastic 8.0


Page 13 of 55

10. Software Status Update

Refer to the Configuration Notes and Whats New with AccuMark in the AccuMark documentation
folder for further up-to-date information relating to your software and installation.
10.1 ACCUMARK HIGHLIGHTS
AccuMark 8.0.8
Software Changes and Enhancements
Refer to the Whats New document in the AccuMark documentation folder.
AccuMark 8.0.8
Changes since 8.0.7

Cut Generation
Implemented Cut Generation in AccuMark AE

Pattern Design 8.0.8
Changes since 8.0.7

Made a correction to allow the pen to work in the proper scale on the entire tablet when
using "Float" mode.

Corrected a problem where saving a rotated or flipped piece could cause the seam and
notches to inverse and change the size or look of the piece.

Piece would distort at the corners if seams were defined without Auto Update and
notches were added manually on the corner. This has been resolved.

AccuMark 8.0.7
Software Changes and Enhancements
Refer to the Whats New document in the AccuMark documentation folder.
AccuMark 8.0.7
Changes since 8.0.6

Data Management
Rename Data was not supporting the question mark, ?, wild card character. This
problem has been resolved.
Reports
Corrected grading problems related to the amounts generated in the perimeter reports.
Previously, it caused incorrect straight/curved perimeter values. Results now agree with
those produced with System Mgmt.
Corrected the amounts for Piece Perimeter Reports on Models to display the total
perimeter inches based on the quantity of pieces in the model. The values now reflect the
same report values as System Management.
ThesinglePiecereporthasbeenfixedtoreportthenotchtypeandquantitycorrectly.

Page 14 of 55

Installation
The installation procedure has been updated to check for the latest service packs prior to
uninstalling the previous software version.
The Install License program has been updated with a Validate button for checking the
license file and key. For instance, it will display a message "Error - License File and Key
Do Not Match" if the incorrect license file is applied.
Marker Plot
When plotting to the Infinity plotter, if large amounts of data were sent and the buffer
setting for passes was high, this system could stop responding and halt the plotter. This
problem has been resolved.
Marking
In previous version, notch on first point of piece will display in wrong direction or be
missing in Marker Making, now this prblem is fixed.
Model
Order As Selected was not working correctly in the Model editor. Not all of the pieces
were being included. This problem has been resolved.
NESTERserver
When sending a group of markers to Nester, if the first marker had an error, Nester
would not continue on and nest the remainder of the markers. This problem has been
resolved.
The overlap value was not activating correctly in sectional markers made by Nester.
Now it fixed.
NESTERserver was not able to access markers on the SQL/MSDE storage areas. Now
it is working.
Error 54 was appearing when opening forms and programs on V8. The error no longer
appears.
Pattern Conversion Wizard
If the style name is missing from the dxf file on import with ASTM/AAMA it will no longer
error out. Like with the 4.3.4 AAMA conversion if the style name is missing the model
name will become the same as the dxf file that was used. If the style name is found than
that will become the model name in AccuMark.
In the Pattern Conversion Wizard, smoothing points for internal lines are now exported to
layers 85-87.
In the Pattern Conversion Wizard, smoothing points for internal lines are now imported
from layers 85-87.
Matched the curve tolerance used for AccuMark in the ASTM conversion. .006 inches
and .152 MM.
Pattern Conversion Wizard will take the file name as the style name when the entry for
Style Name is missing from the dxf file.
Notches on mirror line were converting at the 45 degrees that PDS shows. Now they are
corrected.
If reference notch happens to be on an intermediate point when graded it moves off and
it causes a different number of points on the graded sizes. This problem showed in
exporting data through AAMA/ASTM and has been fixed.
After Exporting and importing in ASTM, half of piece was missing. This has been
corrected.
Now when importing using Pattern Conversion Wizard, if an internal label does not exist,
the letter 'I' will be assigned so that it can be verified.

Page 15 of 55

Now Pattern Conversion Wizard can browse Model/Ruletable files in MSDE/SQL storage
areas by RMB just like in normal SAs to export.
Corrected problems when exporting data and logged in as a limited user (non-admin.
Rights). Previously, it would close the PCW program.
The non-graded notch is in the correct position now after exporting to ASTM format and
importing style back into system.
UltraQueue
If UltraQue queue submission was loaded on a 7.6 AccuMark, it couldn't open. This has
been fixed.

Pattern Design 8.0.7
Changes since 8.0.6

Online Help
AE PDS Help has been updated to properly execute the Search function.
Darts
In some cases using Fold Dart would not add notches to both sides of a dart, or if they
were added correctly, using File/Save would remove one of the notches. This has been
corrected.
Updated Save to correct data which had perimeter lines which were accidentally hidden
as a result of using Fold Dart.
Data
If corrupt data that had no sizes defined was retrieved, the system would stop
responding. The problem has been resolved and a message is displayed stating that the
base size has been defined as 1 and Assign Rule Table can be used to reapply the
correct size line. The message states, Piece xxx found with invalid number of sizes was
automatically fixed. Piece now has one numeric size 1. Use Assign Rule Table to assign
additional sizes.
If a notch existed on the closure point of a piece, the notch would not display in plot or
marking. This problem has been resolved.
Digitize Data
Digitized data that had spaces in the filename was causing errors in PDS. This problem
has been resolved.
Edit
The Open and Save piece processes will automatically assign an internal label 'I' to all
internals that are unlabelled or have invalid labels. Edit Line Info will not allow the internal
label to be unassigned or invalid. This avoids errors when exporting as AAMA data.
In Edit Notch Info, selecting one notch by marquis, when there were multiple notches on
the line, would select more than one notch. This problem has been resolved.
The Notch Type field on the Style Tab in Preferences has been expanded to support
values of 0-99.
In Edit Point Info, if a rule that doesn't exist was entered, and then Cancel was selected
in the Select Rule Table and Edit Point Info dialogs, the graded nest would display on the
piece and the notches were temporarily cleared from display.

Page 16 of 55

Tracking has been updated so that pressing the arrow keys tracks from the currently
selected piece. In previous releases, the keys would track from the currently highlighted
piece and this sometimes caused confusion for users.
When PDS was first opened, notches did not always highlight correctly when selected.
This problem has been resolved.
File
While in File/Open, if a model is selected and then the right mouse button option open
with Model Editor is used, it now opens with the Model Editor window (previously would
open a new PDS window).
If a point was added to a line, the system would not prompt to save the piece when PDS
was closed. Now, if the only change made to a piece is adding a point, the system will
prompt to save the piece.
Corrupt data that was missing a closed perimeter was causing the system to stop
responding when the data was retrieved. This problem has been resolved.
Grade
The grade functions that use charts were not accepting fractions correctly. For example,
1/8 was entered as 1. This problem has been resolved.
The graded nest did not update correctly until another function was selected. This
occurred when using Copy Grade Rule when the nest was displayed and the target piece
had a notch. This problem has been resolved.
Using Copy Grade Rule on a piece when the starting point was the end of a mirror line
with a notch would cause the system to stop responding. This problem has been
resolved.
Create Nest is no longer allowing the piece name to contain invalid characters for the
AccuMark system.
If a piece had only 1 grade rule the measurements displayed for the sew lines would
differ with the functions Measure/Line and Grade/Measure Line. These two
measurements are now consistent for a piece with only one grade rule.
In the Edit Delta function, if a value was changed, then the scroll arrow was clicked
without clicking on the Update button first, the values that were edited before the scroll
arrow would go back to their original values. This problem has been resolved.
Line
In Copy Line, the problem has been resolved that multiple copies don't display for each
line moving until last one is placed when. Every copied line displays in the work area
after being placed.
Using Delete Line to try and delete seam internals would cause the system to stop
responding. This problem has been resolved. The correct way to save a piece with no
sew lines is the turn Hide Seam ON while the piece is being saved. Or, use
Piece/Seam/Remove Seam which hide the seam for the selected piece(s). This way
they will not display in the rest of the system.
The Create Blend function would cause the system to stop responding if the blend point
was selected while in Value mode. This problem has been resolved.
Swap Line on a specific piece was dropping the notches on the line. This problem has
been resolved.
Using Split Line on a perimeter point with an N attribute was still applying smoothing
through the intersection. This problem has been resolved.

Page 17 of 55

Notch
Previously the Angled Notch function could not be used in Value mode. Notches can
now be positioned by specifying a value. The value displayed in the Angle field will be 0
to 180 (pointing inside of the piece) or 0 to -180 (pointing outside of the piece).
Previously Split Piece would make angled notches becomes perpendicular. Now it has
been resolved.
If a notch was added at the corner by dragging along the mirror line, the notches would
disappear after Mirror Piece was performed. This problem has been resolved.
Create Trace would drop notches from certain pieces when traced. This problem has
been resolved.
Perpendicular notches on ends of seam internals were not plotting or displaying in
Marker Making. The problem has been resolved, however the markers need to be
reordered for the notches to display in the marker.
Specific data did not display a notch at an end of line location when it should have. This
issue has been corrected.
In some cases, splitting a line at a notch on a folded dart caused the notch to be
removed. This issue has been corrected.
In certain cases, notches at the ends of dart legs on folded notches would be removed if
the piece was swapped two times. This problem has been resolved.

Piece
The Point/Line Info box did not display consistently for notches in the Walk Piece
function. This problem has been resolved and the box is now always displayed for the
stationary piece.
The Piece/Split Function in Advanced Edition had no default value for Grade Options
when it was first used. This problem has been resolved.
Corrected an issue in Walk Piece that caused the PDS session to closes when the
function was used on specific data.
When pieces were merged, the notch at the intersection of the merge was being
dropped. This has been corrected.
Under certain circumstances, using Merge Piece with the grading displayed would cause
the system to stop responding. This problem has been resolved.
If notches existed on an internal line and the piece was split on that line, the notches
were not always correctly maintained. This issue has been corrected.
Create rectangle in value mode was allowing invalid characters as the new piece name.
This has been fixed.
A problem with notches moving after Split Piece or Create Facing has been fixed.
Corrected an issue with Combine/Merge Piece which would sometimes result in the
notches of folded darts being incorrectly angled on the new, combined piece.
When Split Piece functions were used on a piece with a curved intersection, standard
notches were sometimes converted to reference notches and the notches moved. This
issue has been corrected.
Point
The Add Drills Distance function was not always creating the past drill hole point. This
problem has been resolved.
Previously in Edit Point/Line/Piece, de-selection was not working and the deselected
items were still edited. Now it has been resolved.
If a distance value specified for a new point in Mark X Point happened to be the same
location as a system smoothing point, the mark point would not be added. This has been
corrected.

Page 18 of 55

Preferences
In Preferences, the closing parenthesis was missing from the range for Magnetic
Tolerance. The label now displays correctly.
Made corrections to Digitized Notch conversions for a specific case where the piece
perimeter was qualifying as a digitized notch and converting to a notch when it should not
have been converting.
Seam
In certain circumstances, if seam was defined for a piece by defining it for the individual
lines, an intersection error could occur when saving the data. This problem has been
resolved.
Seam would fail to start under certain conditions (registry key values were missing and
have been updated to contain the needed parameters).
Using Save after updating seam caused the seam internal to distort on specific data.
This issue has been corrected.
The function Swap Sew/Cut has been updated to maintain the correct point numbers on
Seam Corner points. Previously, the point numbers sometimes changed on seam
corners when a piece was swapped.
On specific data, using Swap Sew/Cut could cause Pattern Design to close
unexpectedly.
When working in V7 Compatibility mode, if update seam was used, it was possible to set
the seam mode to Generate Mode. Update Seam has been corrected so that a message
displays if V8 seam settings are selected when running in V7 mode.

Silhouette
When using Trim/Extend Piece, if a value larger than the accepted range of .25/.625 cm
was entered, an error message would display and then the value would still be applied.
Trim/Extend Piece has been updated to only apply values within the accepted range.
The Line/Curve function was deleting the piece or causing the system to stop responding
if 'Create As New Piece' was selected after creating a piece. This problem has been
resolved.
When using Silhouette, if a piece perimeter was entered using Line/Curve and then Add
Notch was used to place the notches, the notches did not always end up at the correct
location. This problem has been resolved.
The Line/Curve function was not repeating, it would exit at the last prompt instead of
looping back to the first prompt. This problem has been resolved.

System
PDS on AE no longer displays a missing entry point error when running on system that
has AccuMark 7.6.x installed.
Removed the APDS-3D menu choices from the File menu since this product has been
discontinued.
When using a WACOM tablet with Pattern Design, it was not always possible to control
movement and selections correctly. Pattern Design has been updated to work correctly
with current WACOM tablet drivers.
View
If the Hide Seam button was toggled while in the Define Seam function, the pieces in the
work area did not always update correctly. Now Seams display correctly when the Hide
Seams button is turned ON/OFF when in Define Seam.

Page 19 of 55


AccuMark 8.0.6
Software Changes and Enhancements
Refer to the Whats New document in the AccuMark documentation folder.
AccuMark 8.0.6
Changes since 8.0.5

Corrected problem that caused a box or drill symbol to appear in generic or hpgl plot data
and cut data output. This occurred on pieces that were split or married in the marker.
Resolved the involuntary closing of a rule table when the mouse cursor became a "+" after
using the Change Sign function on a selected rule.
Corrected Rule Table Sizes with a 'space' in the name. Previously, it gave an Invalid Data
error.
Resolved Order Process problems with models using half-piece sharing. Previously, it did not
process the orders in version 8 if the pieces had 20 character names.

Pattern Design 8.0.6
Changes since 8.0.5

Darts
Resolved an issue where using Rotate Dart on a specific piece would cause the PDS
session to close.
Saving a piece after using Fold Dart with the notch option and the Swap or Replace Line
functions could cause a drill to appear at the dart apex. This has been corrected.
Corrected an issue that sometimes caused notches on folded darts to disappear when
the piece was saved.
Darts folded in releases 8.0.4 and 8.0.5 using the notch option in fold dart displayed an
extra drill in marking. While the drill was not visible in PDS, an extra point id and grade
rule number would display in PDS. This issue has been corrected.


Important Note: If darts were folded in versions 8.0.4 or 8.0.5 using only the notch option or
a combination of options, which included the notch option, please be aware of the following:

If using AccuMark 8.0.5 SPE or higher, pieces do not need to be resaved. PDS and MED
will read them correctly on these versions.

If the data is retrieved onto AccuMark version 8.0.3 or earlier versions, it may display an
extra drill in some portions of the system. Saving "problem" data in AccuMark 8.0.5 SPE
or higher versions will result in the data looking correct in all versions.

Existing markers created in 8.0.4 or 8.0.5 with dart drill problems should be reprocessed
on AccuMark 8.0.5 SPE or higher versions and will then display correctly.

Edit
When running in V7 compatibility mode on the V8 software, Previous (P) and Next (X)
attributes on notches were not preserved when the pieces were saved. This problem
has been corrected. If P or X attributes are assigned in the V8 software the notch is
immediately converted to a reference notch. When this data is saved in V7 mode, the P
and X attributes will display on classic versions of the software.

Page 20 of 55

Change Reference has been added to the AE version to allow editing of the notches after
a P or X attribute is assigned.
In Edit Piece Information, when selecting several pieces at one time, it was possible to
accidentally rename a piece to Multiple.... This issue has been corrected.
Edit Piece Information no longer allows a piece in the work area to be renamed to the
same name as a piece in the piece menu. If the name entered matches one that already
exists in the piece menu, the system prompts that a new name needs to be used.

File
On some data, saving the piece caused the seam internals to convert to regular internal
lines. This issue has been corrected.

Notch
Resolved an issue where editing the notch number on specific data caused the notch
angle to change.
Saving specific data caused some notches to be removed. This has been corrected.
Corrected a problem that caused some data to not display notches when retrieved into or
copied to AccuMark V8 from version 7.

Seam
Copy Piece No Seam on a piece with Seam Corners was positioning seam corner
notches incorrectly. This has been corrected.

AccuMark 8.0.5
Software Changes and Enhancements
Refer to the Whats New document in the AccuMark documentation folder.
AccuMark 8.0.5
Changes since 8.0.4

AutoMark
Added ability to print report and marker display together on one page.
Previously, AutoMark with repeated construction pieces added a construct piece
between every two. Now this error has been corrected.

Backup
Fixed mismatch in AccuMark backup on days in week

Data Management
When delete data from AccuMark Explorer, the dialog box terminology has been
changed to be clearer.

Explorer
The copy function is deleted from RMB on raw digitize data
In old version, when delete a V7 Storage area, and restore it, it will come out a V8
storage area. Now it is fixed and it will not come out so many dos windows as well.
In old version, Locked storage area can be deleted. Now it will not and will give an
prompt message "storage area * is locked."
Data type filter didn't work right in explorer in old version. Now it is fixed.
Save As would stop if a name already existed. Now can state Yes to skipping a
particular name that already exists and continue or Yes to All occurrences of duplicate
names. Then the Save As will continue on with the rest of the items being created.

Page 21 of 55

The data still shows after select Delete and then No. It was disappearing from list until
refresh was done
You can now successfully use drag & drop to copy data to a formatted floppy that does
not already have the storage area structure on it. Previously you would get an error while
trying to transfer the data.
Backups now include the userid information.
In previous version, if there's an error in renaming files, the source files would be deleted,
now this problem is fixed.

General
Limited the character number of storage area when press "New Item" button to create a
new storage area in all "Open" and "Save" and "Save As" windows. Now the maximum
number is 8.
Installation
The initial message that is displayed informing the user that an uninstallation will be
performed first has been improved.

Lay Limits
In 8.0.4, Tilt/Rotate limit will fill the value in the last opened lay limit table. Now it is
resolved.
Lay limits table can now handle 9999 number or row
Different tilt limits for CW and CCW tilt have been implemented

Marker Plot
Printing of the plot queue now has a wider name field so that the entire marker name will
be printed.
Annotation set to GRAIN did not plot where requested. The annotation is misplaced. This
has been corrected
The percentage value for scale in the marker plot parameter table was not storing the
number after the decimal. Now the full value is storing

Marking
You can now modify block / buffer rules interactively
Updated to support more than 5 notch types per marker
Scoop build down in the color matrix menu created refresh problems in the zoom
window. This has been corrected
Auto Process option is now activated in MED
Added New Message when Block-Fuse is created and the Slid in the Marker if Overlaps
are detected
Now you can attach markers with different widths
Markers with Invision options turned on sometimes crashed when sliding the piece
matches. This has been corrected
Corrected print problems from the Marker Making editor. Previously, the marking editor
shut down when selecting the Print function
In previous version, Copy Marker cannot place all pieces same as in original Marker, now
this problem is fixed.
In previous, Marker Making will crash when changing matching lines' options, now this is
fixed.

Order
A new Warning Message has been added when the Order Process uses a Block-Buffer
Rule that is not defined in the Block Buffer Table

Pattern Conversion Wizard

Page 22 of 55

When import style information a warning will be issued for missing creation date, creation
time, author, standard version and curve tolerance if any of them are missing
Now the Pattern Conversion Wizard will no longer overwrite the Rule Table when the
settings to overwrite is set to No.
Pattern Conversion Wizard will now issue a more specific error message if the model
name does not exist instead of Control File in Use message
When internals share an endpoint, export AAMA and ASTM was adding drills to both
endpoints. It no longer does this.
Notch on a curve were not keeping the correct angle after exporting in ASTM mode. This
has been corrected
If Import a .RUL file a warning message will now show if date or time is missing
Removed prompt to click the Right Mouse button to continue after the conversion is
completed. Now the prompt is to press Enter to continue only.
Style export now issues a warning message that a notch type is not setup in the notch
parameter table during processing and no notch is then put on the piece.
ASTM export can now handle exporting U notches on pieces successfully.
Import of style will now distinguish between left check and U notches properly on the
pieces.
When Importing dxf files into the system using a wildcard, if some of the files exceeded
the number of characters allowed, PCW now reports the correctly.
Notches are exporting to different layers to maintain the correct notch types at export
time per ASTM standard. We can now export: Slit, V, T, Castle, U, Left Check and Right
Check notches
If accessing a locked storage area, the lookup for the model name was not giving a
response. Now, there is still not a response, but if type in model name and process, then
there is an error message about the storage area being locked.

Piece Plot
In previous version, Plot Media of Piece Plot cannot update with Plot Destination's
change (select a different queue name from Piece Plot form), now this is fixed.
In previous version, Piece Plot will crash if there has a clerical error in the Size line of
Piece Plot PT, now this is fixed, and it will report this error in Activity Log

Problem Report Utility
The PRU has been updated so that customers could specify their own SMTP email
gateway allowing them to use email addresses other than to gerbertechnology.com. If the
default Gerber gateway IP address is used but a non-Gerber email address is specified,
a warning message is displayed informing the user.
The PRU can be used on the GT WAN in Europe with either mail server's IP address
172.16.249.100 or 172.16.248.100.
In previous version, the email address field only accept no more than 32 characters, now
it can accept up to 64 characters

Rule Table
Printing a range of rules has been made possible now by selecting the from and to rule
number in the Print Dialog box of a Rule Table
It is no longer possible to create a rule table where the smallest size is duplicate.
In previous version, Rule table--Size break values autofill error when change the smallest
size and add some new size lines, now this is fixed.

System
On some Windows XP systems when logging into the system and error would display
after a while a message that SPNSRVNT.EXE has encountered a problem on startup.
This has been resolved.

Page 23 of 55

Pattern Design 8.0.5
Changes since 8.0.4

AM/MM Integration
Corrected problems related to saving MicroMark styles. Previously, hidden internal lines
would reappear after the styles were saved. AccuMark data is not affected by this change
since internal lines should reappear after saving pieces/models.
When assigning annotation indices to annotation lines on MicroMark data, Pattern
Design now checks that the index is in the valid range of 0-255 and only allows one line
per piece to have an index of zero. If the user does not assign an index the line will
automatically be assigned an index of zero if one does not already exist in the piece; or, if
a line with a 0 index already exists in the piece an index of 1 will be assigned.
Saving a model with more than one A or B annotation line as a MicroMark style
previously gave errors because the line indices were all set to zero. Now, when saving
the first A or B annotation line is given an index of zero and the rest of the annotation
lines are given an index of 1.


Page 24 of 55

Darts
Corrected a problem that would cause the PDS session to close when using Fold/Close
Dart on specific data with seam corners on the dart.

Edit
In previous releases, when a marquee was used to select points in Edit Point Info the
Grade Rule field was inactive and the points could not be edited. This issue has been
resolved.
Edit Notch Info did not always clear the selection after apply or an arrow was
pressed. This resulted in notches from previous selections also being edited or
updated. Edit Notch Info has been updated to clear the selection after apply or an
arrow button is used. This allows easier editing and is consistent with Edit Point Info.
The View Undo Buffer function was previously grayed out in the Advanced Edition. It
has now been removed from the menu.

Attributes
X and P attributes were not preserved when data was saved to a V7 storage area. This
problem has been resolved.

File
Corrected a problem, which caused the words in some messages to be cut off and
unreadable.
When creating a new model and adding pieces it is now possible to store newly created
models to devices and storage areas other than the default ones.
When saving a model as a style, if a piece had the same name as the style name and
Extract Style Name was checked in Preferences, the piece could be removed from the
style because a blank name was created. This issue has been corrected.
Pieces added to AccuMark models will no longer automatically be assigned a fabric code
of A. However, if pieces are added to MicroMark style, then they will be assigned to
material group A.
Corrected a problem where selecting Cancel the Close PDS window, while in a function
caused the Right Menu to no longer function.

Grade
If Export Grade Rules is used and there are no grade rules to export there is now a
message 'No grade rules were exported' to indicate that.
Using Edit Delta on a newly mirrored rectangle would cause the system to stop
responding. This problem has been resolved.
MicroMark style data that had tangent notches with curve reference points assigned to
the end of the line sometimes converted with the wrong point used as a reference when
the data was converted or saved as an AccuMark model. This issue has been resolved.

Line
Corrected display issues with directional arrows when adjusting a perimeter or internal
line and selecting the end point of the line.
Resolved an issue, which caused and Out of Range error when selecting the last point
on the line and entering a negative value in the function Adjust Length.
If Zoom was used after Apply in Move Line or Move Offset, a negative value enter
would become a positive value. As a result the line would move in the wrong direction
after Ok was selected. This problem has been resolved.
Rotating both an internal and perimeter line at the same time about a point on the internal
line would cause the PDS session to close if the internal line was selected first. This has
been resolved.

Page 25 of 55

If the lines to be swapped using Swap Line were .03 inches/.075 cm or less apart from
each other, the lines would not always swap. This has been corrected.
Resolved an issue where Create Perpendicular would cause the system to stop
responding on specific data.

Measure
The Distance 2 Point function was displaying 2 copies of the measurement. The function
now displays the measurement one time.
The selection of Measure/Distance 2 Point has been made consistent with the other
functions.
Corrected an issue where using the Exclude Region or Toggle options in Measure 2
PT/Measure Along Piece could cause the PDS session to close if no pieces were in the
workarea or no points had been selected for measuring.

Notch
Corrected a problem where notches with grade rules assigned to both the notch and the
notch base point did not position correctly on the graded sizes when the piece was
stacked and rotated.
Resolved an issue for specific data, where adding positive seam allowance caused
notches at a dart to move.
On specific data, when the piece was flipped, the notches would disappear. This
problem has been resolved.
Notches were not displaying at the correct location on cutout 'fisheye' darts. This
problem has been resolved.

Other
Functions such as the create piece functions, which will prompt for a new piece name if
the piece already exists in the model/style, were allowing invalid characters to be entered
for piece names. This has been corrected.
Under specific circumstances, using the full screen menu option when selecting and
placing pieces into the workarea could cause the message Cannot zoom to selected
area to appear. This issue has been corrected.

Piece
When using the merge piece function on certain data, if the lines to be merged were
within .03 of length the function would fail. This problem has been resolved.
Combine/Merge pieces would prompt the user to enter a piece name twice even if a
name had already been entered. This has been corrected.
Resolved an issue where using Copy Piece No Seam on a piece with curved
intersections was not smoothing the curves correctly.
Updated Walk Piece so that it could be used successfully on specific data that caused
problems in previous releases.
In some cases, tracing pieces from internal lines was adding notches where none
previously existed. This has been corrected.
Corrected problems for specific data that caused the PDS session to close when
attempting to open the data.
Scale Piece has been updated to maintain existing grade rules already assigned to the
piece. New, modified rules are no longer created.
Combine/Merge piece caused the PDS session to hang when used on specific data while
the graded nest was displayed. This issue has been corrected.

Point
Corrected an issue for MicroMark data, where angled notches were not maintaining their
angles correctly when saved.

Page 26 of 55

If no pieces were in the work area, selecting the function Reduce Points would cause the
PDS session to close. This has been corrected.

View
In previous releases, selecting from the right side of the menu options in the top of the
Custom Toolbar dialog caused the screen to scroll and the arrow keys needed to be
used to display all the options again. The Custom Toolbar dialog will now display a
scrollbar if there is not enough room to display all the choices.
Corrected display of symbols which were sometimes doubling after using the Split Piece
functions to split a piece.
Changing the setting for Hide Seams in Preference did not apply the setting to the
pieces in the work area immediately. This has been changed so that the seam
automatically displays or hides as soon as the option is changed in
Preferences/Options.
The Show Base Size and Show Non-Base Size functions have been removed from
the Advanced Edition menus.

AccuMark 8.0.4
Software Changes and Enhancements
Refer to the Whats New document in the AccuMark documentation folder.
AccuMark 8.0.4
Changes since 8.0.3


Corrected problem related to Move Data and Copy Data "with components" in AccuMark
Explorer / Utilities. In previous version it did not copy the components.

In previous releases of AccuMark Version 8.x it was possible to create an Alphanumeric rule
table with the same size listed more than one time. This has been corrected and the
functionality is now consistent with Classic AccuMark.

If lower case letters were used to enter size names in the rule table, the growth amounts
were not save for those sizes. The rule table will now change the characters to upper case
while saving.

Corrected problem converting style pieces when the primary reference line of the piece is
also the opposite grade axis and the piece needs to be reoriented.

Previous versions of Grade Checker would report mismatches, however when displaying the
pieces in the viewer they looked accurate. Two changes have been made to improve this
situation. Pieces that were reporting mismatches that had none will no longer report
incorrectly. Also, color has been added to the viewer to highlight the region with the
mismatch. See the What's New for additional information on the Viewer enhancements.

The Order editor gave an error when opening an existing order on a system with a target
length, using German regional settings. This problem has been resolved.

HPGL plot data was not generated correctly. A comma (,) was used instead of a decimal (.).
This problem has been resolved.


Page 27 of 55

Pattern Design 8.0.4
Changes since 8.0.3

Darts
The function Fold/Close Dart End would cause the system to stop responding on specific
data. This problem has been resolved.
Corrected an issue where Rotate Dart did not always rotate the dart correctly.

File
Improved the function Edit Model in PDS. Previously after editing and closing a model,
the system would stop responding for a while. This problem has been resolved.

Grade
Corrected a Grade Measure problem. On several previous versions, Grade/Measure
Distance to Notch and Distance 2 Point/Measure Along Perimeter would display measure
line results when measuring along the beginning of a line.
The measure function Distance to Notch was not giving correct measurements on non-
base sizes. This problem has been resolved.

Notch
Several functions which created new perimeter lines, such as Swap and Trace, were
positioning notches so that they pointed to the outside of the piece. This problem has
been resolved.

Piece
If a piece was traced and one of the lines selected was from a mirror line, the notches on
the mirror line would point to the outside of the piece. Now the notches are staying to the
inside."

Seam
Corrected an issue where certain combinations of seam settings and seam corner notch
settings could cause the notch to be in slightly different locations on the graded sizes.

View
Previously the grid would not display when pressing Apply Grid in Screen Layout when
the Show Grid Button off. This problem is now resolved.
AccuMark 8.0.3
Software Changes and Enhancements
Refer to the Whats New document in the AccuMark documentation folder.
AccuMark 8.0.3
Changes since 8.0.2

Annotation
Added Capability NOT to Rotate annotations. This can be set up by adding the Environment
Variable: NO_FLIP_ANNO=1. The variable must be written in Capital Letters.
Block Buffer
In previous version, Block Buffer maintained input of previous input. Now it is resolved.
Corrected problems when deleting one rule in BLBU. Previously, it would always delete the

Page 28 of 55

last rule.
Edit Digitize
Edit Digitize-Undo insert row/insert row problems have been corrected.
Explorer
Save As has been corrected so invalid characters are no longer saved in the data item
names.
Increased the total number of storage areas. The previous internal limit was 200. Now it is
unlimited.
Save as w/Components can now be used with model piece name with Chinese characters.
The data type field correctly displays the word Alteration when selected for filtering data.
Previously it would display three dots.
AccuMark Explorer now allows you to delete raw digitized data using the right mouse button
and selecting delete.
General
Previously, Lconvert and dxf converter were untranslatable. They can now be translated.

AccuMark applications have been updated to with complete information in the Help, About
boxes, including the application name, version, and copyright.
User Environment
Duplicate process parameters have been removed due to the re-introduction of the user
environment parameter table: P-User Environ. For instance, in Order Process, the View,
Preferences will bring up the UEPT instead of a separate list of process parameters.
Installation
When AccuMark is installed on a drive other than C: installation it will now prompt the user
with a message about overwriting the AccuMark storage areas. Previously it did not.
Added the c:\dxf for the ASTM/AAMA projects. DXF converter does not create any directories
and the LConvert program calls xppermfix for its own created directories.
When starting the installation the user may inadvertently double-click on the html page, thus
launching a second install and causing problems with the installation. The installation now
catches the second click and gives the message "this program is already running".
Piece Plot Parameter Table
Plot Single in P-Piece-Plot PT now generate internals on every size. Plot Nest still plots the
internals once, if they have no grading.
Model
Corrected shift and ctrl key combinations in the model to fill in with select pieces.
Corrected problems saving an order with Save As and when Order Name=Marker Name is
checked. When this option is checked and Save As is used to change the Order Name, the
marker name inside the order will update to the same name as the order.
Laylimits
The picture in Laylimits help was Markplot Form; not Laylimit Form. It' has been fixed.
Order Processing
Order Process has been corrected so the status message is correct when components are
missing. Previously the message was incorrect.

Page 29 of 55

Corrected problems with F-rotation points on pieces when order processing to a marker.
Pieces converted from MicroMark will now process and rotate pieces with F-rotation lines
correctly.
Marking
Corrected problems with Constructs disappearing when moving marker origin and resizing
the Marker window down the marker. The disappearing of the Contructs from the temporary
view, caused pieces to overlap the Constructs as end result.
Point-to-point matching-Setting same plaid and relative stripe matching between 2 pts,
Marker Making hung if valid matching location not found. This has been corrected.
Marker Plot
Plot to Existing Dos files now prompts for replacement of the existing plot file.
The save dialog box no longer appears when closing the Marker plot window.
Plot Bundle By Model now plots the first models, the second models and so on, each with the
same Bundle Codes.
Markers that contained split pieces from fixed piecing lines were closing the program when
sent to the plotter. Now they process with no errors.
Constructs are no longer affected by the shrink-stretch in Marker Plot.
AccuMark cannot half piece sizes that are called from the model option. An error message
will now generate should this condition occur. Previously, plotting a marker with Halfpiece
created incorrect plot data with double pieces.
Pattern Conversion Wizard
If DXF file contained negative x or y values, the convert into AccuMark didn't complete.
Now the conversion can handle negative coordinates.
During conversion there used to be a limit to the number of errors that could occur. Now
there is no limit.
Conversion was leaving splits on lines where they weren't originally. Now the lines are split
as they were initially.
Corrected problems when an invalid device was accessed. An error message will also
appear.
Corrected problems with mirrored pieces not keeping the coordinates on the mirror line.
That is fixed.
If sample size was missing from rule table to import, AAMA would end. Now it will give an
error message about missing sample size and not convert the table. If selected all rule
tables with an '*' then after reading the error message, press enter on keyboard, the
conversion will continue with next one.
Warning messages will now be issued if the measurement units are not included in the DXF
files for PCW.
Import of PCW dxf file will now be stopped if style name or sample size information is not
included.
The log file will now display only if Pattern Conversion Wizard finds an error or warning
message.
ASTM exported pieces with different character size for different annotate piece messages.
The characters Exported and Imported with the correct values.

If grade rule table does not exist in the storage area that the model is being exported from,
then a dummy rule table of 0 bytes will no longer be created. If the rule table exists, it is
exported along with the model.
Conversion was not keeping all the line splits that were on the pieces originally. Now it is.
Error 'Can't read grade rule table' occurred when try to export rule table A1-Ladies. Now
the grade rule table exports without error.

Page 30 of 55

PCW can now access and correctly read the names of SQL storage areas.
ASTM- corrected problems with Grade Reference Lines not being Parallel. "Rule Data may
be Incorrect" was being logged in to the LOG file without the name of the piece.
If sample size existed but is not in the size range of the rule table, the conversion used to
take the first size as a default. Instead, now there is an error message, and the conversion
will stop.
AAMA or ASTM export with 'Export as one line segment' was causing pieces when
imported to crash PDS. Now it can be yes or no without closing out PDS.
The overwrite raw digitized data flag now works. If set to "no" then PCW will not overwrite
the data on Import.
PCW will now give user an error if a piece name is longer than 20 characters.
Export data is now reading the registry to include the character default setting from PDS
with the dxf output file.
If storage area is not found in PCW, then 'control file in use model name: xxx' will now
report a more informative error message.
Plotting / Winplot
Corrected blank paper advance problems on the Infinity plotters.
Corrected interpretation of metric values from DWG AutoCAD files.
Rule Table
Corrected grade rule validation when the maximum rule numbers are exceeded. The Grade
Rule Editor Id will now only allow rule numbers up to 9999.
Corrected Rule table values. They can now recover to original value after changing precision
The rule table size line has been corrected to allow one size such as only size 1. In Classic it
was possible to define a sizeline with the same size for the base, smallest, size step and
break; when this size is the ONLY break.
Security
The new serialno.exe application will return other pertinent information in addition to the key
number (see attached serialno.jpg). Serialno.exe is installed with PE/AE into the AccuMark
directory and can be run manually. The Install License application has also been updated to
display the same information.
Pattern Design 8.0.3
Changes since 8.0.2
AccuMark to MicroMark Integration
Invalid AccuMark Model data that is saved as a MicroMark style can cause corrupted style
data. Putting a check in to detect the invalid AccuMark data and fixing the data have
resolved this problem.
Style Notes were not working correctly on Windows XP systems. This problem has been
resolved.
Darts
The Rotate Dart function was not highlighting the rotation point with the correct symbol
shape. This problem has been resolved.
The Rotate Dart function would cause the system to stop responding if Cancel was selected
after selecting the pivot point. This problem has been resolved.

Page 31 of 55

Data
Style data that contained flipped piece saved in version 2.0.7 or earlier, could have piece
perimeters that were saved counter clockwise. The data now saves correctly.
Edit
Edit Point Info has been changed to prompt for the rule table less often. If the rule entered to
assign to the piece exists in the piece already, or exist in the rule table assigned to the piece,
the system will not prompt for the rule table.
When using Edit Piece Info, if tracking between pieces, the original piece remained in the
highlighted color. This problem has been resolved.
If the thumbtack was used while the Edit Point/Notch/Line/Piece Info box was displayed,
some functions were not selectable. This problem has been resolved.
When changing a notch type in Edit Notch Info, the depth of the notch was not updating
correctly. It now updates correctly when the notch type is changed.
Clear All did not correctly in the Edit Notch Info function. This problem has been resolved.
Edit Point Info did not filter grade points when using the Shift key selection mode and setting
the Filter tab to Grade Points. Now Edit Point Info filters grade points correctly when the filter
tab is set to grade points.
In Edit Point Info, if points were selected using a marquis the system would stop responding.
This problem has been resolved.
In Edit Piece Info, the rule table field was previous enabled. It is now grayed out.
Edit piece was not activating other fields when clicking next or previous button when the
mouse stayed inside the info box. Now the fields are activated wherever the mouse is.
File
Corrected a problem where saving specific model data two times in a row sometimes caused
the PDS session to close.
In previous versions of Advanced Edition, Create New Storage Area in PDS (create new
folder icon) created V8 storage areas. PDS in Advanced Edition now creates V7 storage
areas.
Saving or rotating a piece with measurement could cause directional lines of measurements
to change position. This problem has been resolved.
In release 8.0.2, styles containing invalid notch types could not be successfully saved as
AccuMark models. Attempting to save would cause the PDS session to close. This issue
has been corrected.
If PDS was opened from AccuMark Explorer by selecting multiple pieces using the CTRL key
the system would stop responding. This problem has been resolved.
Data retrieved from a NETWORK storage area could not be saved when in v7 mode. This
problem has been resolved.
The title of the Duplicate Point Number prompt was changed from Silhouette 2000 to Pattern
Design.
In the Material Group field of the Piece Description page of the Style Description, the letter
O was missing from the drop-down box. The letter O has been added to the list.
Grade
If the Copy Grade Rule function was used on a piece with seam lines could cause the system
to stop responding. This problem has been resolved.
In specific cases, using the function Copy Line could cause the PDS session to close. This
issue has been resolved.
The error message for unavailable grade rules did not display when a model is opened into
PDS using AccuMark Explorer. This problem has been resolved.
Corrected a problem that sometimes caused the OPP to be dropped from notches on
MicroMark styles when they were retrieved into PDS.

Page 32 of 55

Interface
When not in a function, and Snap to Geom was ON, it was possible to activate the Beg, End
and Distance fields in Value mode. This problem has now been resolved.
If a particular model was opened from Explorer into PDS, the system would stop responding.
This problem has been resolved.
Keyboard shortcuts have been removed from menus of AE/GMS.
Line
Line/Oval Orient was not using angle measurement correctly when making a very large oval.
Now the distance and angle measurement is in correct increments.
Replace Line did not always give the correct results when many internals where selected or
the internals were on the outside of the piece perimeter. This problem has been resolved.
Corrected how perpendicular lines are created on a line when a notch is located at the same
location. Sometimes the perpendicular line was actually parallel to the X-Axis instead of
perpendicular to the line itself.
Selecting a notch in the functions Create Blend or Offset Uneven sometimes caused the PDS
session to close. In addition, moving a notch on a line that was created using either Create
Blend, Offset Uneven or Copy line sometimes caused the PDS session to close. These
issues have been resolved.
Swap line sometimes gave the wrong result on specific data. This has been corrected.
Measure
Several inconsistencies existed in the Measure/Distance 2 Line function. These problems
have been resolved.
Miscellaneous
When using the Measure/Perimeter 2 Point function on a flipped or rotated piece, two
measurements would display, one flipped/rotated and the other correctly. This problem has
been resolved.
Notch
In some cases, creating a new line using mirror line would cause the notches to point to the
outside of the piece. This has been corrected.
On specific style data, adding a variety of notch types could cause the PDS session to close
when attempting to Save the style. Afterwards, the style could no longer be opened
successfully. This issue has been corrected.
Piece
If a piece was traced and one of the lines selected was from a mirror line, the notches on the
mirror line would point to the outside of the piece. Now the notches are staying to the inside.
In Advanced Edition, after using the function Combine/Merge Piece, the resulting grading
was not always correct. This problem has been resolved.
The Add Mark and Add Notch options have been removed from Walk Piece in the Advanced
Edition.
In previous versions, Annotation would move to the outside of a newly traced piece. Now
Annotation will keep the correct position after tracing.
If an unfolded, mirrored piece was saved, the piece would be changed to a non-mirrored
piece. This problem has been resolved.
Create Trace was not always maintaining the shape of the traced geometry. This problem
has been resolved.
When Shrink/Stretch was used on a piece, the newly calculated grade rules were not being
maintained on the ends of the seam corner lines. This problem has been resolved.
If seam was added to a piece that had been traced counter-clockwise, the seam would be

Page 33 of 55

added to the wrong side of the piece. Positive seam would create sew lines and negative
seam would create cut lines. This problem has been resolved.
The Set and Rotate function would cause the system to stop responding if Cancel was
selected after the third prompt. This problem has been resolved.
Point
Corrected a problem where using Move Single Point or Move point to move a standard notch
sometimes caused the PDS session to close out.
Pressing the left and mouse buttons together in space (not over any geometry) in the
functions Add Point, Mark X Point, Digitize Line, 2 Pt Line, Perp Off Line or Circle Ctr Radius
would cause the system to stop responding. This problem has been resolved.
Preferences
The Storage Area name field in Preferences on the Paths page was too short to see the
entire Storage Area name. The field has been made longer.

Problem Report Utility
An additional functional area, 'Alterations', has been added to the Problem Report Utility.
If AutoSave was set ON in PDS 2.0.x, and then PDS 8.0 was used the setting for AutoSave
was still ON even though the option was removed from Preferences. This problem has been
resolved.
Seam
If using the Mitered Corner function in cursor mode, if the system could not find intersections
between the miter line and the adjacent cut lines, a line would be drawn out in space. This
problem has been resolved.
View
In previous releases, the function Show All Points was displaying smoothing points as
intermediate points. Smoothing points are now displayed using circle symbols.
Changing the setting for Hide Seams in Preference did not apply the setting to the pieces in
the work area. Now the option in Preference and the button at the bottom of the workspace
work consistently.

AccuMark 8.0.2
Software Changes and Enhancements
Refer to the Whats New document in the AccuMark documentation folder.
AccuMark 8.0.2
Changes since 8.0.1
AutoMark
In AutoMark when Screen only was selected, the View Log function showed the
temporary file, not the log file. Now View Log always shows the Log File. When Screen
Only was selected, the temporary file that is written to wasn't being cleared, so previous
processes write still being shown. Now before a Process Entry or a Process Job Queue
Function is performed, the temporary file is cleared.
In AutoMark, instead of prompting to overwrite for every marker that exists, a Checkbox
was added to Overwrite Destination Marker if Exists. If the destination marker exists,
this checkbox will dictate whether the marker gets overwritten or not.

Page 34 of 55

Data Entry Forms
Corrected problems with invalid characters getting saved in the model. A message will
appear if an invalid character is detected.
Data Management
Dragging data from a floppy through the AccuMark Explorer would crash. This has been
fixed.
Right mouse click on selected Items + Drag and Drop, now does a scroll on Storage Area
list in AccuMark Explorer.
The Save As functionality on right mouse click allows now renaming multiple items at the
same time.
Edit Digitize
Edit Digitize-Clear Contents in right mouse button didn't work. Now this issue is resolved.

Updates have been made to Edit Digitize when Save or Save As is used. Open from
digitizer no longer automatically saves as stored digitized data, and leaves it up to the
user to perform the save or save as. When saving as the same name, raw digitized data
is removed from devq. When saving as a new name, raw digitized data remains in devq.
A function has been added in Edit Digitize to allow the user to add a row after the last
entry in the digitized data. Use the right mouse button and select Insert Row at End.
Edit Digitize no longer automatically stores a copy of devq digitized data as Stored
Digitize Data in the storage area. It is only stored if explicitly saved by the user.
In Edit digitized data editor, the scroll bar did not work properly. Now it scrolls like it
should.
Some pieces would be split at every point after using ASTM conversion into AccuMark.
Now only the corners are split.
Digitize data that contained lower case characters were preventing the piece from being
verified. Now it will verify regardless of upper case or lower case.
Edit Digitize correctly uses the storage area specified in the digitize/verify options for
verification (for example, to look in that storage area for the corresponding rule table).
Edit Digitized has been improved to only store verified data upon success. Previously
data was being saved as Stored Digitized Data when errors were encountered.
Verify on digitized pieces has been updated to correctly display the digitized or verified
piece names (they were getting mixed).
Explorer
Plot process options Local and DOS options were conflicting. When Dos File is
Selected, the unused fields are grayed out. When a plot queue is selected, the Default
Dos Directory field is grayed out.
Export Zip with components has been updated to prompt the user when not all
components exist. Selecting OK will continue and create the zip. Selecting Cancel will
stop and delete the zip.
General
XP Permissions has been updated to no longer remove any permissions already set, but
to just add Full Control to the Users group for AccuMark Family data and application
directories and registry entries for Gerber key."
Installation
Added disk requirement to installation section of release notes.
Initial installation on a Window NT machine caused error failed to register. It no longer
fails to register.

Page 35 of 55

The software installation properly processes the Back button.
XP Permissions is automatically run from the Installation of AccuMark 8.0.2. It is no
longer necessary to run it manually unless additional programs outside of the C:\userroot
directory structure are installed. Examples: Lconvert and MTM.
If running on a system as some other user than loaded software, then Replay was still
running when opened PDS. Now replay doesn't run.
Marker Plot
Fixed problem with Side-by-side mini markers. Restarting a plot with side-by-side mini
markers was causing bad plots. This problem has been resolved.
Added default Marker-Plot PT field in Marker Plot form.
Marker Plot process no longer shuts down when Die Cut Blocks option is selected in
MarkerPlot-PT and Processing the marker plots.
In Marker Plot, Lookup and marker selection has now a choice to plot as selected.
Marking
Corrected issues with retrieving markers. Previously, when opening one marker then
another and another, the memory started to climb, resulting in marker making problems.
Solved marking slowness when using Matrox Millennium graphic card. Change the
"Troubleshooting settings to reduce the acceleration" in Windows Display Properties
down by 1 setting.
Copied markers were losing their status when transferred. Now whatever status they
have they keep after copying to another storage area.
Fixed overlaps caused when using BUTT.
Model
Piece selections keep the "as selected sequence.
The ability to re-order pieces in the Model editor has been implemented. A group of
pieces or a single piece can be selected, and then by dragging the left most edge of the
entries the order can be changed.
Order Processing
The Order Process form has been updated to allow you to choose only one storage area
for processing at a time. It will lock in the storage area name once entries have been
entered in the form. This will avoid confusion and possible problems when using different
source and destination locations when processing from many areas."
Pattern Conversion Wizard
If seam lines were on the outside of the piece before sending through the ASTM
conversion, some of these lines were gone after converting back into AccuMark. The
piece is now changed so that the cut lines are the perimeter shape and sew lines are
internals labeled 's'.
ASTM conversion will not import or export pieces with grade rules out of range. It will
now prompt user to export the grade rules before continuing.
When an AccuMark style with modified grade rules (rules with * or # signs) is exported to
ASTM format the conversion will stop and record the message information into a log file."
Corrected Export problems data that has modified grade rules. When ASTM interface
recognizes this condition, a user will be asked to export grade rules. Now, grade
information will be preserved after exporting grade rules. Previously, once pieces had
lost some grading information, the grading didn't correspond with the original piece. A
few grade points had no grade rule id assigned."
Corrected the export of stripe lines in layer 9 to be two point lines instead of polylines.

Page 36 of 55

Previously, they were converting to polylines.
Automatic piece numbering was shown twice on the CONFIG screen. Changed the
second display back to Starting Piece Number (for Automatic Numbering).Different
configuration files (CNF files) are now created for versions 4.3.4 and 8.0.2 Version 8 will
refer to ASTMCVT.CFG and version 4.3.4 will remain using AAMACVT.CFG
Piece Plot
Piece annotation was not following the grain line when selected in the Piece-Plot-
Parameter table. Now it does.
Added Paper Advance after deleting Active jobs.
Look up in Piece Plot has now a choice to plot as selected.
Piece Plot Parameter Table
Fixed registry entry for device or storage area when they are blank.
Rule Table
Rule Table now prompts to save changes when updates are made and Exit (close) is
chosen.
If only typed in a rule number in a rule table and didn't activate the x or y columns the rule
would be deleted when stored. Now it stays and fills in with zeroes.
Improved the retrieval time on very large rule tables. A process dialog was also
implemented to monitor the retrieval progress.
If changed the grade option to Base up-down cumulative the grade rules were not
changing correctly. Now they do.
Size name in a rule table was not accepting / or \ and now it is if select alphanumeric
first.
When type over the sample size in grade rule table, it used to crash. It no longer
crashes.
Corrected problems when using Import Rule or PC-Rule. Previously, using this function
two times repetitively to a new rule table crashed.
Security
The serialno.exe application now displays the message This Key Has Not Been Properly
Programmed. Replacement Key Required" for keys with errors.
View/Quick View
When opened up View plot from the plotter queue, the window would open up behind the
queue window. Now it opens on top."

Pattern Design 8.0.2
Changes since 8.0.1

AccuMark/MicroMark Integration
Saving a Model as a Style has been updated to allow the piece category or description to
be saved as the MicroMark message and piece flips defined in the model are also
converted. See the What's New document for more information.
For Style data, adding intersection notches and references notches to a piece sometimes
caused the notch information to be removed. This has been corrected.

Page 37 of 55

Notches were left on dart lines when an AccuMark model was saved as MicroMark
model. This resulted in the dart being invalid in MicroMark PDS. This problem has been
resolved.
Now when a MicroMark style is saved as an AM model, the MM piece message can be
saved in the category or piece description. There is a radio button choice on the style tab
of Preferences.
Save As with export rules will now export grade rules with 0,0 growth.
On some data Save style would give the error message "Error grading piece." However
the graded nest could be displayed correctly. This error message has been eliminated.
Darts
Corrected problem with Grade Rule changes after rotating a dart and keeping the
Internals.
Rotate dart was not showing the center apex line during function, now the highlighting is
correct throughout the function.
In some cases, using the function Fold Close Dart did not correctly add a grade point
which caused the dart hat to be incorrect on some of the graded sizes. This has been
corrected.
Rotate dart on a piece with negative seam, system gave intersection error messages.
This has been corrected.

Digitize Data
Edit Digitize through PDS correctly uses the Path variable for verifying digitized data, and
also properly displays the source path for the digitized item.

Edit
When changing a grade rule on a piece with multiple grading lines, and canceling the
function at the select grain line prompt, the graded nest would be displayed.
Applying GLI no longer hangs if right button OK/Cancel is selected without selecting line
in Edit Point Info.
File
On specific style data, the system was incorrectly prompting that notch base points
needed to be added for notches on the mirror line. This has been corrected.
Now notches viewed in PDS will update as soon as the notch table is stored.
Corrected intersection errors on styles retrieved into Pattern Design and saved as an
AccuMark Model.
Dialog box for error message for invalid rules now is big enough for the whole message.
When a piece is brought down to work area, if seam is not hidden and the seam
allowance lines were updated, they appeared as modified lines. Exiting the window
would bring up a warning message to store pieces since they had changed. The seam
lines are not showing modified now and the warning message is not appearing now.
Prefix in File/Create model was not allowing more than 10 characters in the model name.
Now it will allow more and will truncate the model name with a warning message to the
user if the name is over 20 characters.
Create model/ Prefix will now stays on even after closing PDS window.
Saving AccuMark data that had notches on the ends of dart lines as MicroMark style data
caused the system to crash. This problem has been resolved.
The opposite's quantities were staying in the piece menu after a style was saved to a
model. Now the quantities are actually saving to the model and quantities are correct in
the piece menu.

Page 38 of 55

If save Style as a model and then go to Save as and give a new name but no to overwrite
the piece, the system no longer crashes.
PDS no longer crashes after modifying the Notch information on specific pieces and then
selecting the function save. The save had prompted to reassign double point numbers.
Corrected the display for MicroMark digitized files. Previously, File/Open/MicroMark
Digitizer files did not display digitized files if a character followed the .R extension in the
PDS lookup. For example: a file named 12345678.R90 did not display in the list.
Grade
When grading functions were used on the end of a mirror line, the grading was not
always changed on both endpoints of the intersection. This problem has been resolved.

Copy Grade Rule has been added to the Advanced Edition.

On specific data, removing a seam corner could cause the intersection of the seam
internals to shift on the graded sizes. This issue has been corrected.
Corrected problems associated with opposite grade rules in MicroMark styles.
Previously, Styles with Opposite grading were not storing the correct growth in the
AccuMark pieces. Now the rule numbers become modified rules instead of the same rule
as the rule on the other piece.
If using the Export Rules option in Save As, modified rules are not successfully exported
and the new rules assigned to the piece. This problem has been resolved.
Grade/Export Rules was leaving invalid rules behind giving an error. Now there is no
error.
On specific data, swapping seam line would cause the seam line to shoot outside the
piece.
Corrected problems when Exporting Rules from the Grade menu and then saving the
model. Previously, Save Model would close down pattern design.
Grade Checker
The Grade Checker has been improved to compare the smoothed geometry of V7 and
V8 data. In previous versions the non-smoothed data was compared.
Interface
Corrected problems when using the Escape key. If the pop up size list box is displayed
while piece is graded and Escape key is used to close it will close down PDS.
Split piece shows direction arrows in value mode now.
PDS now refers to the regional settings when using value input so data can be entered
accordingly.
Line
On certain pieces, adding a digitized line would cause the smoothing of the perimeter line
to change. This problem has been resolved.
Offset Even on a seam line with Replace on used to crash PDS. Now no crash and no
new line either.
Offset Even on the closed internals would close out the PDS window with no messages.
Using the same function on an internal line near the mirror line also resulted in a crash.
In certain data, the functions Swap Line or Replace Line could cause the system to
crash. This problem has been resolved.
Move offset on piece with curved intersection - if there is a small line segment left - the
offset won't work instead of giving an intersection error.
Swap Line sometimes causes notches to be lost. This problem has been resolved.

Page 39 of 55

Under certain conditions PDS would crash when using the function Clip line. In some
cases it happened when grading crossed over the clipped line. This has been fixed.
Corrected problems when using Replace Line to replace an internal with a perimeter line.
In one example, Replace Line was closing down PDS when using the function to open a
closed dart.
Many functions were updated to drag internals using Preference - Internal Pattern.
PDS now doesn't crash if you zoom or drag scroll bar when Move and Rotate Line.
Measure
The function Measure Dist 2 Line would cause the system to crash if Snap to Geometry
on and an end of line point was selected.
Two sets of Measurements were showing in several Measure functions if the font size is
not the system default.
Measure Perimeter 2 Pt/Measure Along Piece-dimension lines show correctly and
measurements are correct also now.
Miscellaneous
If piece was listed in model editor multiple times, the warning message when opening
model in PDS listed the same piece name multiple times. Now it will only list it once.
Fixed the Reference locations and Pivot points' color display problem when the geometry
is being dragged.
Notch
Corrected a display issue where notches would sometimes disappear from display when
Hide Seam was used. The notches would then reappear when the screen was refreshed
on another function was used. This has been corrected.
Corrected a problem that sometimes caused notches to not display on seam internals
when the line was split at the notch.
Tangent notches on MicroMark pieces with line or seam extensions did not grade
correctly when the data was saved as AccuMark data. This problem has been resolved.
Now if the notch type is not valid for AccuMark, Retrieving the pieces will give a warning
message about invalid notches and the notch value will display higher than 5 to show
which notches need editing.
When splitting a piece, if the splitting line has notches, the new pieces did not always
have the original notches from the splitting line.
On specific data, invalid notch angle information caused the notch to display incorrectly.
This issue has been corrected by resetting the notch angle to the default 90 degrees so
that the notch displays properly.
Other
Corrected problems with rotated annotation. Previously, the annotation would disappear
when the OpenGL driver was used.
Edit Digitize through PDS has been fixed to properly display the digitized commands in
the Edit Digitize form when you try to open a digitized piece that has errors.
Piece
Pieces in a style that were mirrored and had seam defined for the first line of the piece
would cause PDS to hang when the function Unfold Mirror was used in conjunction with
the View All Sizes function. This has been corrected.
In AE 8.0 version, the Flip Piece quadrant options were all grayed out. Now these
options are enabled.
Tracing pieces with notches that have duplicate point ids would cause the system to stop
responding. This problem has been resolved.

Page 40 of 55

Corrected the problem that Notch type is 2 not 1 being added to both ends of mirror line
when using the function Mirror Piece.
Corrected problems with the function Split Piece Vertical when a notch was in the middle
of the splitting line.
If line to split is at a perimeter intersection - the notches will be dropped after splitting.
Now the notches stay.
Corrected system problems with the Trace-Piece function. Sometimes the function would
close down the Pattern Design session.
Piece Split on Line was crashing if grading crossed lines and seam allowance is defined
on the piece.
Resolved an issue that caused the PDS session to close unexpectedly when Swap
Sew/Cut was used on specific data.
In some cases, tracing a piece caused the PDS session to stop responding. This issue
has been corrected.
Corrected problems with Split on Line. Previously, this function closed down PDS when
the splitting line had a notch on the end of an internal.
On certain data, if both the seam allowance and the graded nest were displayed, using
Split Piece would cause the system to crash. This problem has been resolved.
Corrected an issue where Trace Piece was not copying the grading of standard notches
when the grading was applied to the notch rather than the base point.
Added a message to Trace Piece to alert user if traced piece contains invalid grade
rules.
Point
The location points for multiple points and drills were not showing when selected. They
show now hollow red boxes.
Corrected the problem that Point - Move Smooth functions leave selected lines in
selected color if Cancel.
Preferences
Corrected the Preferences Paths so they will no longer change to the current selection.
when Styles and models are opened from AccuMark Explorer. Previously, when you
opened a style using AM/MM Explorer the Preferences/Options Paths/ Micromark Paths
were being reset to the drive letter that you selected the style from instead of maintaining
the original settings.
When running PDS on a Windows XP system, the OK, Cancel, Save and Apply buttons
were displayed too low in the Preferences dialog box. This problem has been resolved.
Seam
Square Corners can now be added to a corner that has seam allowance defined on one
of the adjacent lines.
Swap seam with Copy Grade Rule has been simplified to just copy the grade rules to the
corresponding points on the seam internal. This fixes the reported problem of the grade
being corrupted on flipped pieces.
Will no longer get intersection errors when swapping a piece that has a 0 seam
allowance amount adjacent to other lines that have seam defined.
Added a correction for specific data where saving a piece with Seam Corners toggled off
caused the piece to distort and get intersection errors.
System
If an invalid MicroMark path was input - it would give an I/o error. Now there is a default
path if an invalid path is input.

Page 41 of 55

The PDS splash screen allows any error messages encountered to be displayed on top
of itself (so they are no longer hidden behind the splash screen).
Sometimes after using PDS intensively for over one-half hour, it became slow, using up
lots of memory, and eventually could crash. This problem has been resolved.
When Replay is running and the operator is logged on as a user, the PDS screen would
not respond to windows interface actions. Replay has been stopped.
View
Corrected problems when Point Numbers are displayed in PDS. Previously, the points
were being saved and processed through to Marker Making as graphic debris.
When opening data in PDS, the current window updated with all the pieces, then when
brought them to work area updated the current piece box again. Now the current piece
window is empty until piece(s) are brought into work area.
The dimension ticks were changing scale when displayed and the scale of the work area
was changed. This problem has been resolved.

AccuMark 8.0.1
Software Changes and Enhancements
Refer to the Whats New document in the AccuMark documentation folder.
AccuMark 8.0.1
Changes since 8.0.0

General
Version logging has been added to the AccuMark applications for improvements to error
reporting.
The AccuMark Family Product CD now installs an "Install License" program that can be run
from the LaunchPad or AccuMark V8 folder from the AccuMark Explorer, Utilities page. This
utility easily copies your license file into the proper location for use by the AccuMark
applications. Refer to the Whats New document for details.

The program (serialno.exe) to read the key number has been included and is now installed
into the AccuMark folder on the hard drive.
AutoMark
AutoMark has been updated to properly prompt the user for overwrite when a destination
marker name was manually entered.
AutoMark now uses the correct storage area when using the right mouse button from
Explorer on a marker and selecting Automark.
The outline of the pieces in the marker were displaying as grey when in Preferences they
were selected to display black. With nonstandard colors settings of windows display it
seemed that the lines were not displaying. The colors are now correct.
Corrected Automark Delete Job List function to prevent it from greying out the items.
Previously, selecting "delete job list" when No was selected, would grey out "delete job list"
and "process job list".

Page 42 of 55

Launchpad
Documentation links have been updated and are available through the LaunchPad,
AccuMark V8 folders, and at the end of the install. Informational message indicating Adobe
Acrobat Reader is required to read documents.
Forms and Editors
Improved lookups and F2 to reference the correct storage area.
Corrected the laylimit editor to accept category entries beyond 150 lines.
In the Order Editor, the Storage area name was sometimes greyed out or locked to the wrong
storage area. It has been fixed.
Corrected Save prompt in rule table when adding a Point Attribute 1-notch. Exiting the Rule
Table will now prompt user to save changes.
Changed Go to Rule to automatically position cursor in the field for size or rule number.
Corrected problems with Undo function in Rule Table to correctly restore rule information
after using Delete, Insert Rule and Clear Column.
In the Rule Table editor, improved selection of the right mouse button functions and corrected
the display of these selections so they no longer overlap the rule value display.
When trying to Cut out a rule, it produced the value out of range error and it was not possible
to continue without using end task. Corrected function so it is possible to continue after
cutting a rule, however the "Value Out of Range" message will still appear when trying to
save. An "empty" rule must be deleted before saving.
Corrected grade rule table display errors when opening a rule table when another one is
currently displayed. Previously, if the first rule table opened had some grade rules and the
second rule table opened in the same rule table had more grade rules, the second rule table
would show blank grade rules which displayed the message "Value out of Range (9 to 9999),
prevent the user from continuing.
Rule Table form has been updated to prompt the user to enter a valid rule number when a
rule has data but no rule number. Previously if you tried to close without entering a rule
number, the editor would crash.
Corrected overwrite problems when using Import Rule function. Previously, Import made a
copy of the rule rather than overwriting when expected.
Corrected saving of a rule table with an un-named rule. Prompt no instructs user to enter a
valid rule number.
AM-Explorer
When executing a File, New Model from a storage area in the AccuMark Explorer, now
defaults to that storage area. Previously it was defaulting to the last access storage area.
AccuMark Explorer has been updated to display the storage area version number as
referenced by the software version (i.e. version 7 or 8).
Order Process
Corrected layrule process problems when split pieces were not placed in the marker. Layrule
process now places all pieces with fixed piecing lines.
Corrected overwrite problems in Orderload Process form from Launch pad . Previously, if
marker name field had a different marker and Overwrite marker was set to no in preferences,
the marker was overwritten without a warning or error.
Corrected Order Process when Marker is created in source storage area and copied to the
destination. Previously, there were problems with the destination storage area; sometimes
closing down the program.
Markermaking
Corrected problem with Copy marker function on folded goods with folded pieces. Sometimes
markermaking would shut down and generated splices would return to zero.

Page 43 of 55

Corrected distorted grading in marker making on pieces with a grade rule applied to a point
on the mirror line. In previous release grade points on the mirror line were incorrectly graded.
Corrected problems encountered with matching lines used in 8.0 Match line markers made in
8.0 will need to be regenerated or ordered using 8.0.1
Plotting
Piece Plot: Corrected the Character Size field to use the maximum defined range for
Character Size. The range of .125-3.00 (imperial) will now accept 3.0 and the range of .318-
7.620 (metric) will accept 7.620

Pattern Design 8.0.1
Changes since 8.0.0

File
Pattern Design or the Model form would crash if you tried to open more than 140 items at the
same time. The crash has been eliminated, however, you may not be able to retrieve the
entire selection at once due to the size of the items.
AM/MM Integration
Corrected a problem where saving a style as a model created modified rules when it should
not have.
The Notch Conversion Table on the Style tab in Preferences/Options has been updated to
include the following changes. Default notch types for new installations are 1,2,3,4,5,5
instead of 5,1,2,3,4,5. Notch type conversions work when saving MicroMark data to
AccuMark and when saving AccuMark to MicroMark. When saving an AccuMark Model as
a MicroMark style, notch depths from the Notch Conversion Table are used only if the
current notch depths are zero.
Corrected a problem for a specific style where PDS prompted that notch base points were
missing when attempting to save the style rather than when it was opened.
Corrected a problem for specific MicroMark data where saving the style in PDS caused the
grading to be different in Classic MicroMark PDS.
Corrected a problem where using Fold Dart would sometime create unused graded rules.
Edit
Corrected a problem where invoking Edit Point information and tracking over a seam corner
caused the PDS session to close.
Edit Notch Information has been updated to display the notch depth for notches on
AccuMark pieces.
The Edit Info Dialog has been slightly enlarged so that the scroll bars for the tabs could be
removed. This allows easier viewing and navigation within the dialog.
Under certain circumstances, when tracking was selected from the user input the buttons
would display partially off the bottom edge of the dialog. This issue has been corrected.
Corrected a problem where selecting a point with an R attribute in Edit Point Information
sometimes caused the PDS session to close.
File
When using Save as and switching the option from saving a piece to saving a model/style,
the system would prompt twice to select the model/style name to save. This issue has been
corrected.

Page 44 of 55

Corrected a problem for specific piece data where the seam internals distorted when the
piece was saved.
Corrected a problem where intersection errors would display repeatedly for specific data
when it was placed into the work area.
Corrected a problem for specific data where a piece created by merging two existing pieces
would not save.
Grade
Measure 2 PT/Measure Straight was not drawing a dimension line to indicate where the
measurement was taken. This issue has been corrected.
In version 8.0 it was not possible to select a location other than the default path when
assigning a new grade rule table. This issue has been corrected.
In version 8.0.0, seam corners points would display double symbols on the graded sizes.
This issue has been corrected.
Assigning of point id's to end points was updated to be consistent with Classic AccuMark.
Grade Checker
Corrected a problem where specific piece data was causing the Grade Checker to close
out.
The Grade Checker has been enhanced so that multiple sizes may be selected and viewed
together.
Translation support has been added for the GradeChecker/GradeViewer utility.
Enhancements have been made for Point Count Mismatch reporting in the Grade Checker.
The Grade Checker has been updated so that points that are within tolerance of the shape
are not included in the count. The checker also verifies that points with ID's or notches are
within tolerance.
The Grade Checker utility has been enhanced to include support for Metric. In previous
releases the tolerance could only be specified in Imperial amounts.
The Grade Checker utility has been updated to support checking of pieces with graded
grain lines.
The Grade Checker has been updated so that the settings selected by the user are
remembered and preset the next time Grade Checker is used. In the previous version, the
values needed to be selected each time Grade Checker was opened.
Grade Checker has been updated so that pieces with positive seam and piece that do not
grade are no included in the mismatch count.
Display
In previous releases, dimensioning lines did not always display correctly for some
functions. Several functions have been updated to display dimensioning lines correctly.
For example, pleat and fullness functions now correctly display the dimensioning lines at
the pivot point when in value mode and angle is selected.
Lines
Corrected a problem in Rotate Line where the PDS session would close if a perimeter line
was selected for rotation and the rotation point was a point on the seam internal.
In some cases, the 'Move Multi Line in Reverse' option was not working. This issue has
been corrected.
Corrected a problem where Merge Line was causing the PDS session to close when used
on specific data.
The ability to use Curved Intersection on an Assym Folded piece, as was possible in
Classic AccuMark, has been implemented in PDS.

Page 45 of 55

Misc.
Corrected a problem where the thumbtacks changed size when zoom in or zoom out was
used to change the scale and the graphic renderer was set to OpenGL.
Translation support has been added for the notch table displayed using the function
File/Edit Parameter Tables/Notch.
Notch
Corrected a problem where notches with delta rules on graded internals did not display
after using Copy Piece No Seam on the piece.
Pieces with F Rotation and Reference notches distorted the perimeter shape when F
Rotation was displayed. This issue has been corrected.
Corrected a problem where the PDS session stopped responding if a line was split at a
notch, and the display was then set to unclipped and the line was merged back together.
PDS has been updated to display notches either as symbols, as in Classic AccuMark, or to
display the actual notch depth. Use the new option Show Actual Notch Depth on the
display tab of Preferences/Options to control how notches are displayed.
Notches on the perimeter lines at the ends of the mirrored lines were not angled correctly in
marking or plotting. This problem has been resolved.
Other
The table of contents in Help has been updated to display the help topic for Envelop
Corner.
When saving a style, if the default path was invalid, the title bar of the message displayed
the wrong title for the message. This issue has been corrected.
Piece
Trace will now open in the last option selected as well as defaulting to normal first.
Corrected a problem where the orientation symbol was not displaying in the selected color
when the piece was selected.
Walk Piece was not always applying the notch type specified. This issue has been
corrected.
Corrected a problem for specific data where saving a piece recently created by merging two
existing pieces caused the PDS session to close.
Corrected a problem where unfolding a specific mirrored piece caused the PDS session to
close.
Corrected a problem for specific data where a notch that had an X attribute did not display
on the smallest size.
Plot - PDS
In release 8.0, a new media could not be selected from the Plot Form. This has been
corrected.
Seam
Under some circumstances, using Copy Piece No Seam would result in reference notches
not displaying on the internal lines created from the seam internals on the original piece.
This issue has been corrected.
Corrected a problem where the seam internal would not draw correctly on a curved
intersection when negative seam was applied.
Corrected a problem where seam corners sometimes applied an N attribute, which would
change the shape of the adjacent line.
PDS no longer allows a style to be saved when the digitized boundary is different than the
current boundary. MicroMark does not allow the digitized boundary and the current
boundary to be different, so this change is consistent with Classic MicroMark. When this

Page 46 of 55

condition is found, PDS alerts the user and indicates that 'Swap Sew/Cut' or 'Fix Bound
Type' may be used to update the pieces so that the style may be saved. In previous
releases styles could be saved when the boundaries did not match. When retrieved into
MicroMark PDS, PDS attempted to make the boundaries match and the pieces displayed
as modified. In some cases, this also resulted in incorrect geometry in marking.
The Advanced Edition has been updated to always use seam settings of 'Grade
Seam/Corners', 'AutoUpdate Seam' on, 'Seam Extensions' off, 'Adjust Seam Grading' off,
regardless of previously installed software versions or registry settings.
When running in V7 compatibility mode, the Fix Seam Corners checkbox is not applicable
and is now displayed grayed out.
View
In version 8.0.0., View Point Attributes took a long time to display the attributes on screen.
This issue has been corrected.
AutoSave has been removed from Preferences since new methods of working and using
Pattern Design often conflict with AutoSave and cause it to not work properly. If you have
been working successfully with this option, the option may still be triggered using a command
line switch. An easy way to do this is to create a shortcut to the Sil2000.exe, which is located
where you installed AccuMark 8.0. After the shortcut is created, right button on the shortcut
and select properties. On the shortcut tab, add a '-v' in the 'target' field after the path outside
of any quotes. For example, D:\Program Files\Gerber Technology\AccuMark V8\Silhouette
2000\sil2000.exe -v. When you run Pattern Design from this shortcut, the AutoSave options
will display on the bottom of the General Tab in Preferences/Options.
Corrected a display problem where a point previously highlighted with the mouse button
down would stay highlighted after the mouse was moved away.
The option 'Make new renderer the default renderer' has been removed from the Graphics
tab of preferences. 'Save' may now be used to make a newly selected renderer the default.
Color Fill was not displaying correctly for pieces with perimeters that touched in places, such
as dart tips touching or overlapping. This issue has been corrected.
The AccuMark Piece compatibility options on the General tab of Preferences/Options have
been changed from a single checkbox to two radio button choices to make the options easier
to understand.
Corrected a problem where drill symbols did not display when symbols were turned off in
preferences.
AccuMark 8.0.0
Changes since 7.7.1

LaunchPad
Added title descriptions for each icon in LaunchPad
Editors
The editors have been changed to confine lookups to the storage area of the first selected data
item in that storage area. Previously, it was possible to select data items from other storage
areas which resulted in processing errors.
The Order Editor in a non-English operating system had some difficulties with characters in upper
and lower case combinations. Corrected keyboard input to change all text to upper case
characters once saved.
AM-Explorer
Generate Marker did not refresh the display list in order after processing. Corrected function to
display new markers automatically in correct order of the list.

Page 47 of 55

Added a warning message to the AccuMark Utilities - Delete Storage Area function to display
Are You Sure You Want To Delete Storage Area:xxx?
Generate Marker was misleading when Overwrite Marker option was set to No. Now a process
dialog box will display No Overwrite.
Plotting
Bump lines previously did not annotate on the MicroJet plotter. This has been corrected.
Corrected HPGL and Generic plot output problems. When plots were processed as DOS files
they were all created as generic plots. Plot process to a DOS file will now process the correct
files for generic and HPGL formats.
Placed pieces in a marker were showing up misplaced in the marker plot. This occurred when a
piece line was too close to the starting point of the piece. Problem was corrected in
Markermaking. Old markers with this problem need to be re-made and stored. New markers are
handled correctly.
Corrected View Plot and Plot output inconsistencies with the MSQ border annotation.

Pattern Design
Implemented new security for support under AccuMark Advanced 8.0
Darts
Rotate Dart now maintains the grading by using the grade rule of the rotation point on the
dart tip. This result is consistent with Classic PDS and maintains the geometry correctly.
Fold/Close Dart no longer causes the PDS session to close when PDS cannot find
intersections for the dart fold lines.
The Rotate Dart function caused the PDS application to close if the pivot point was on
top of the open point. This problem has been corrected.
A new error message has been added to Fold/Close Dart when the dart can not be
physically folded due to the geometry shape.
Dart functions now have the option to select internals to move. Selecting internals when
prompted allows the internals to move relative to the dart as it is manipulated. This is
similar to the option in fullness function.
Data Related
Corrected a problem on specific data that was causing intersection errors to occur or
PDS to close when the piece was placed in the PDS workspace.
Resolved a problem with specific piece data that could not be opened in PDS until it was
retrieved and saved in Classic PDS.
Specific data generated intersection errors when saved. This problem has been
resolved.
Edit
The arrow keys on the keyboard can now be used to track around a piece in Edit Point
Info, Edit Notch Info, and Edit Line Info. The down arrow goes to the next point and the
up arrow goes to the previous point. The left and right arrows are used to move back and
forth within a text field. The cursor and focus remain in the last field edited after the Apply
button is used or another point is selected.
In Edit Point or Line Info, it was possible to select an editable field while drawing a
selection box. This would cause errors when editing the data. This problem has been
resolved.
Automatic Point and Piece tracking was not working correctly when using Edit Point Info
or Edit Piece Info and selecting the Track button. This problem has now been resolved.

Page 48 of 55

If a piece had multiple Grade lines, the point filters could not be used to change the grade
rule of multiple points. This problem has been resolved.
Corrected a problem with Edit Point/Line/Piece information where using the thumbtack to
pin the dialog open, making several edits and then exiting the dialog caused the PDS
session to exit.
Using the thumbtack in Edit Point Information and then canceling out caused the PDS
session to close. This issue has been corrected.
File
In previous releases, invalid characters such as '+' could be entered as part of a piece
name. The AccuMark does not allow invalid characters and they would cause problems
in the rest of the system. Invalid characters are no longer permitted to be entered as part
of a piece name.
Using Save As on a model now maintains the model information such as fabric codes,
flips and comments.
New, consolidated messages display when pieces from the model being retrieved do not
exist on disk or already exist in the piece menu. Previously, a message displayed for
each piece. The new messages display once and list all the piece names in one
message.
When using Close Model/Style, the device and path now display as read only fields.
Grade
In previous releases, some data that only had grading defined for one end of the mirror
line would display differently between PDS and Plotting. This issue has been resolved.
Create Nest no longer causes the PDS session to close if many additional points are
chosen for grade points.
The Grade/Measure Line function would give incorrect results on MicroMark pieces that
had notch base points after the notch instead of before the notch. This problem has
been resolved.
Corrected a problem where placing the pieces into the work area individually or as a
group gave different results for the graded sizes. This issue occurred on specific data
with specific seam settings.
On some data the orientation of the grain line would change a slight amount when the
piece was saved. This problem has been resolved.
The Show Non-Base Size function has been removed. The functions Piece/Create
Piece/Create Graded Size and Grade/Edit Size Line/Change Base Size are available to
the user.
Selecting a large number of points during the 'additional grade points' prompt in the
Create Nest function would cause the PDS application to close. This problem has been
resolved.
Mirrored pieces that only had grading on one end of the mirror line sometimes displayed
between PDS and Plotting. This issue has been resolved.
electing smoothing points during the 'additional grade points' prompt in the Create Nest
function would cause the PDS application to close. This problem has been resolved.
Notch placement was incorrect when X and P attributes were used to control grading.
This problem only occurred on some data and only when in the swapped state. This
issue has been resolved.
In previous releases, using Show Non-Base Size on a piece with Z or R stacking
attributes did not give the correct results. The function Create Graded Size may be uses
with the Z and R stacking attributes and give the correct display.
Lines
On specific data, using replace line would cause the PDS session to close unexpectedly.
This problem has been corrected.

Page 49 of 55

Internal Cutouts, graded or non-graded, now process correctly for marking. In previous
releases, internal cutouts that were graded did not always display in marking.
While working with Move Point functions the Beg., End., and Dist. fields were not
displaying the line lengths. This has been corrected.
Corrected a problem occurring on specific data, where using Replace or Swap Line
would cause a notch to move to another line.
On specific data, merging multiple internal lines at one time caused the PDS session to
close. This issue has been corrected.
The PDS session was closing when trying to split a line and the Tracking Information
window was opened and locked on the screen. This issue has been resolved.
In specific cases, notches moved when a line was split or smoothing was toggled on and
off. These issues no longer occur with the new treatment of notches.
Measure
Occasionally when the Measure/Line function was used and then the piece was moved
in the work area, additional measurement text was left behind in the work area. This
problem has been resolved.
The Measure/Perimeter 2 Point function would cause the application to close if the Zoom
function was used between the first and second point selection. This problem has been
corrected.
Piece
The Trace function now displays the function name Trace properly when the function is
activated from the dropdown menu, hotkeys, or custom toolbar/
Tracing a piece with the graded nest displayed sometimes resulted in the error pieces
too far apart. This problem no longer occurs.
The function name displayed at the top of the Function Option area has been changed
from Normal-Sew to Trace when in the Create Piece/Trace function.
In some cases, using Show Non-Base Size and then unfolding a mirrored piece did not
always display correctly. Using the new function Create Graded Size resolves this issue.
Walk Piece now reads the System Preferences for Metric and Imperial and will display
the values in the appropriate format.
Tracing a piece with stacking applied did not always give the correct graded result. This
issue has been resolved.
Piece Menu
Piece to menu has been corrected so that the display is refreshed when using Piece to
Menu is used and point numbers are also displayed.
Pieces would no longer display in modified color after using Piece to Menu pieces. This
problem has been resolved.
In previous releases, renaming a piece in a model to a piece name that already existed in
the storage area would result in the wrong geometry being retrieved if a second copy of
the renamed piece was placed into the work area. This has been corrected. If a piece is
renames, it is marked as modified. Also, for models, if a piece is renamed to a name that
already exists in the storage area, saving the model will automatically overwrite the piece
with the same name with the one from the model.
On specific data, saving a newly traced piece caused some internal lines to disappear.
This problem has been corrected.
Points
The X and Y value fields, which are not applicable for notches, have been disabled in
Add Notch.

Page 50 of 55

Print
Print has been updated so that the grade rules print at the same size, relative to the
piece, that they are displayed in PDS.
Print Preview has been updated so that clicking Exit no longer causes the PDS session
to close.
Seam
The Function Options for notches were removed from the Remove Corner function
because they were not applicable.
In previous releases, if Swap line was used and the resulting piece had less than 3
perimeter line, the PDS session would close. This issue has been corrected. If the
resulting piece will have less than 3 perimeter lines, PDS will automatically split a line so
that 3 perimeter lines exist.
When the function Copy Piece No Seam was used on a piece that had Seam Corners
with notches, the notches would reposition on the copied piece. This problem has been
resolved.
The function Grade/Measure Line did not work correctly on some data with Seam
Corners. An error message would be displayed, or the application would close. This
problem has been resolved.
Duplicate notches and intersections errors were appearing for specific data when using
certain seam settings. This issue has been corrected.
Normally when a piece is modified, the geometry is displayed in the modified color as
defined in Preferences. When the Swap Sew/Cut function was used the geometry did
not changed color. This problem has been resolved and piece display in the modified
color after the Swap Sew/Cut function is used.
Intersections on the base size of specific data moved when swap sew/cut was used.
This issue no longer occurs.
In previous releases, using Swap Sew/Cut could cause the grading on the piece to
change. This issue only affected specific data using certain seam settings, and it has
been corrected.
The smoothing of seam allowance internals has been improved so that the seam
internals will remain parallel to the perimeter of the piece. Certain data with few
intermediate points used to define a curve could display sew and cut lines that were not
parallel. This problem has been resolved.
View
Pressing the Snap to Geom button when no workspaces are open no longer causes the
PDS session to close.
In previous releases, some functions did not always show the selected object (such as a
drill) in the selected color. This issue has been corrected.
In some functions, graphics were not refreshing properly. This issue has been resolved.
Resizing the PDS window now makes the workspace larger or smaller, maintaining the
scale of the pieces, rather than increasing or decreasing the display of the pieces to fit
the workspace.
The system was allowing to enter a comma in the Value Input fields. Now, if a comma is
entered an Invalid numeric expression message is displayed. After clicking OK, the field
where the comma was entered is blank and a new value has to be entered to complete
the function.
If Show Non-Base size was used and then the growth of a notch point was edited to
exceed the growth of the line, Show Non-Base and Show Base Size could not display
another graded size or the base size properly. This problem no longer occurs. Notches
may now be located on different lines in different sizes.
Selecting Verify by Label when there are no pieces in the work area no longer causes the
PDS session to close.

Page 51 of 55

If a category title was dragged into the work area from the Custom Toolbar dialog the
application would close. This problem has been resolved.
Prefix Style Name has been updated to only prefix the style name once even if Extract
Style name is not selected.
Using Show Non-Base Size on pieces with X and P attributes did give consistent results.
This issue no longer occurs.
Corrected an issue where Show Non-Base Size altered the growth amount for a grade
rule. This problem only occurred on data with two different grade rules at an intersection.
Refresh display has been enhanced. It may now be used while in another function.
The splash screen displayed when PDS opens up has been changed.
Using the wheel button on the mouse to scroll sometimes caused the intersections on
pieces to shift. This issue occurred on specific data and has been resolved.
Notch positions are correctly maintained when using the middle wheel of the mouse to
scroll. This issue affected specific data.


Changes since 7.7.0

Annotation
The lookup feature for the Annotation field was not activated on an inserted row. This
issue has been resolved.
Automark Edit
A button has been added show the job list called "View Job Queue".
Automark properly saves the destination marker after process, whether it is the same
name as the source marker, or to a new marker name.
Title bar reflects the correct storage area name for the marker being opened
(previously if you select a marker from another storage area it did not update the title
bar).
Automark Edit properly closes just the print preview window (previously the entire
editor would close also).
Misspelled word corrected in the status messages "Error opening Automark Queue".
Allow editing of erroneous data in a field when process is selected. Previously if an
invalid value was entered and Process was selected, it gave an error message, but
processed the data with a 0 value.
The Piece Goods Cost field is automatically closed when process is selected (the
user does not have to use the enter key).
Automark Edit correctly calculates and displays the marker width, length and
utilization to the screen and/or in the log.
Fixed problem when using "process entry" several times (no longer hangs system).
Fixed error when the Automark job queue contains at least 3 entries, and you select
view queue, and then you choose OK to return to the program.
Tools icons now match to their text tip.
Block Buffer
The Go To Rule feature properly displays the requested rule (previously it was
always going to the last rule).
Edit Digitize
The Edit Digitize form correctly displays the menu item \ (was incorrectly displaying
as \' ).
Add a function "retrieve original" to retrieve the original digitized data.

Page 52 of 55

Add "go to rule #" function
Using Undo after Delete Row properly returns the deleted row.
The Save function no longer displays the lookup dialog when prompting to save
changes for the edited data.
Explorer & Find
Corrected Copy and Move data functions when copying a model or order with
components from one storage area to another storage area. Copy will now check for
existing pieces and data item components in the designated storage area.
The AccuMark / MicroMark Explorer is now called the AccuMark Explorer.
AccuMark Explorer now allows you to send data to Mail Recipient if the option was
enabled during the installation.
The AccuMark Explorer allows you to create storage area names in Chinese (on
Chinese operating systems).
View Plot on Windows XP operating systems properly displays PIECE plots with Tool
or Entity parameters.
Copy model has been implemented in the AccuMark Explorer.
Export
The Export dialog box now has an option to include components in the zip file. This
capability is also available in the Copy function (position the mouse over a folder name in
the All Folders window and use Paste Components). The option is not available when
pasting in the Contents window. Available for AccuMark data only.
General
Corrected decimal precision rounding problems. The system correctly displays the
appropriate values when the precision is changed (changing the precision determines the
number of decimal places to be displayed).
The Screen no longer flashes when tab fields are removed while closing the form.
Installation
The "Check System Requirements" option properly indicates Windows 2000 Service
Pack 2 and the Hotfix or Service Pack3 is installed (previously it could not find SP3).
LaunchPad
Documentation is now accessible from the Launch Pad on NT operating systems
If the Launch Pad was opened more than once on Windows 2000 systems, and both
were docked to the side of the desktop windows using the "-->", the entire desktop
display got reduced to a very small portion to the side of the Launch Pad. This problem
has been resolved.
Implemented Import and Export from the Launch Pad that saves toolbars and
preferences. You can import to another system, but make sure to keep all three
checkboxes checked to ensure custom settings are the same from one pc to another.
Laylimits
Delete row improperly caused a "Mandatory field, entry required" error message to
appear when Save was selected. This has been resolved.
Laylimits will prompt to save changes if edits have been made and you choose X to
close the form.
You are now able to delete the DEFAULT row using the right mouse functionality
when selecting cells from multiple rows.

Page 53 of 55

Marker Plot
Corrected Marker Plot Save option. Selecting the Save checkbox will now save the
plot file in the storage area (Plot Destination = Local). Can be saved with the same name
as the marker or with a new plot name.
The labels 0-15 have been added to the drop down selections for the Label column
in the Label Tool Mappings section.
Marking
The rounding of metric values for the length was not accurate in Marker Making. For
example a length of 4 meters appears in the status window as 3 meters 100 cm.
(100cm=1 meter). This issue has been resolved.
Selecting the 'X' in the title bar of the Marker Making window could cause the system
to stop responding. This problem has been resolved.
Incorporated additional Bundles functionality, including unplace bundle, retrieve
bundle, flip bundle, and flip to original.
In marker making, when a marker containing constructs was closed, a crash could
occur. This problem has been corrected
In marker making, when "folding adds piece" and "piece view" are both set, the
wrong pieces would show in the piece view. This problem has been corrected.
If a corrupt marker was opened (a marker with a size of 0 bytes) another marker was
displayed in marking. Checks have been added to prevent this from occurring.
In some cases, if a marker had become corrupt, pieces labeled a certain size were
actually a different size in the marker. This problem has been resolved.
A new option has been added to be able to highlight just the piece perimeter or the
entire filled piece.
Matching
Default setting of plaid or stripe type is set to "none" (previously it was being set to
"relative").
Order
Previously you would get an error message if you did not enter either a lower left or
upper right coordinate for constructs. The Help message states that you could use first
two, any three or all four coordinates to define the construct. This has been resolved.
After an order is opened, the message correctly displays the Ready status
(previously the message displayed "Processing, Please Wait").
Order Process
Corrected problem with split piece seam amount specified in the order when
Preferences is set to Metric. It is now properly maintained in marker making.
Piece Plot
Piece plot on AP plotters with stacking on will plot to completion (previously there
were instances when the plotter would stop after plotting 3 pages).
Rule Table
Selecting Help in the Rule Table properly displays the appropriate information
(previously the piece plot parameter information was being displayed).
Sometimes when adding additional sizes to the size line, the form would improperly
display the new sizes after a close & open of the rule table. This has been fixed.
Copy and Paste in the Rules page gave an error message that the rule number was
out of range, but did not allow you to edit and correct the field. This has been fixed.

Page 54 of 55

After adding a new rule to a table, and then trying to import that new rule into a
second table, you would get the error message "Incompatible Size line". This has been
resolved.
Autofill properly fills the remaining rows with the value entered in the row above
(previously the rows were being filled with 0).
Changing the grade options from Small-Large Incremental to Base Up-Down
Incremental or to Base Up-Down Cumulative properly converts the values in the rule
fields.
Starting dialog size is now large enough to display the first three columns on rules
tab. Previously when the rules tab is selected the columns on the right side were
cropped.
Creating a rule table with numeric sizes, using 1 as the smallest size, a size step of
2, and only two size breaks that included the base size and one other size incorrectly
gave the error message for an incorrect size line. This issue has been resolved.
The Rule Table now verifies data entered in the sizes and size breaks before
allowing the user to enter the Rules tab or Save.
Rule Table now allows the user to create a table with only two size breaks.
The functions "go to rule", "go to size", Next and Previous rule from the toolbar have
been implemented.
Fixed the hot key "ctrl+I" for Import Rule (was executing an Insert Rule).
When Searching for a rule and a match rule found, if you stop the search it will now
keep the rule found as the current rule (before it was returning to the first rule)
When executing Go To Rule for a rule and a match rule found, if you stop the
process it will now keep the go to rule as the current rule (before it was returning to the
first rule).
If any invalid rule number was entered the message "Value out of range: 0-9999"
would be displayed. This has been corrected to display the correct range for the rule
numbers.
The rule table performs checks on the size line to verify when the base size must be
listed in the size line. For example, the Base Size doesn't have to exist in the Size Breaks
List ONLY if the SizeType is NUMERIC and the grading method is SMALL-LARGE
INCREMENTAL. ALL other cases, the base size must be listed in the size breaks, or an
error is reported.
User Environment
The precision and data is maintained when switching the number of decimal places.
Previously rounding could occur thus changing the data in the field.
Corrected the seam amount (metric) for split pieces in marker making to reflect the
same value specified in the Order Options.

Page 55 of 55