You are on page 1of 1

2008 Thermo Fisher

Scientic Inc.
All rights reserved.
All trademarks are the
property of Thermo Fisher
Scientic Inc. and its
subsidiaries.
Specications, terms and
pricing are subject to change.
Not all products are available
in all countries. Please consult
your local sales representative
for details.
In addition to the
ofces listed below,
Thermo Scientic
Niton Anaylzers
maintains a network
of sales and service
organizations
throughout the world.
Americas
Billerica, MA USA
US Toll Free: 800 875-1578
+1 978 670 7460
niton@thermosher.com
Europe
Munich, Germany
+49 89 3681 380
niton.eur@
thermosher.com
Asia
Central, Hong Kong
+852 2869 6669
niton.asia@
thermosher.com
Australia
Rydalmere
+61 (0)2 8844 9510
niton.aus@
thermosher.com
www.thermo.com/niton
The Niton

XL3t 500/600 x-ray tube-based x-ray fuorescence (XRF)


analyzer with GOLDD technology is purpose-built for your most
demanding applications. This revolutionary instrument is engineered for
high performance, reliability, and ease of use, providing further evidence of
our leadership through excellence in innovation. The chart below details the
sensitivity, or limits of detection (LOD) in ppm (mg/kg) of the Niton XL3t
with GOLDD technology analyzer, specifed for SiO
2
matrix, SiO
2
matrix
with 10% iron, and a typical Standard Reference Material (SRM). With
a 50 kV miniature x-ray tube, GOLDD technology, and multiple primary
flters the most versatile confguration ever offered in handheld XRF
instruments the Niton XL3t lowers the detection limits for trace elements
to a level never before seen with a portable XRF analyzer.
Thermo Scientic Niton XL3t 500/600 with GOLDD Technology
Elemental Limits of Detection in Environmental/Mining Type Samples
Limits of detection (LODs) are
dependent on the following factors:
Testing time
Interferences/Matrix
Level of statistical confdence
Please Note:
Ongoing research and advancements
in our Niton XL3t with GOLDD
technology analyzers will lead to
continual improvement in many of the
values detailed in this chart. Contact
a Thermo Fisher Scientic ofce, or
your local Thermo Scientic Niton
product representatives for the latest
performance specications. Though
great care has been taken to present
true data that can be repeated in
the real world, it is worth noting
LODs can vary signifcantly when the
presence of constituent elements in a
sample uctuate.
For applications that require
sensitivities close to those listed, it
is recommended that samples be
analyzed as a feasibility study on-site
with a company representative.
For denition of terms see ASTM
Standard E 456, Standard Terminology
Relating to Quality and Statistics.
1. Denition and Procedure for the Determination
of the Method of Detection Limit, 40 CFR,
Part 136, Appendix B. Revision 1.11. U.S.
Environmental Protection Agency. U.S.
Government Printing Ofce: Washington,
DC, 1995.
Limits of Detection in Environmental/Mining Type Samples
TIME 60s per lter 60s per lter 60s per lter
Element
SiO
2
Matrix
(ppm)
SiO
2
+10% Fe
Matrix (ppm)
SRM
(ppm)
S 250 600 500
K 75 175 400
Ca 40 75 300
Sc 10 40 60
Ti 30 110 125
V 15 35 40
Cr 25 45 25
Mn 25 75 75
Fe 30 N/A 75
Co 20 250 125
Ni 25 55 40
Cu 15 20 20
Zn 8 13 13
As 5 7 7
Se 3 5 5
Rb 2 5 5
Sr 3 3 8
Zr 4 6 9
Mo 4 7 5
Ag 10 10 15
Cd 7 9 8
Sn 13 20 15
Sb 10 20 15
Ba 45 55 35
Au 7 10 10
Hg 5 8 8
Pb 4 8 8
Element list shown is not exhaustive. For limits of detection for elements not shown, including
light elements, such as Mg, Al, Si, P, and Cl, or for further optimization of any elements listed
above, please contact a Thermo Fisher Scientic ofce, or your local representative.