You are on page 1of 78

Bulletin 100

IEC Contactors
3

Bulletin 100
15 Sizes, 9600A
Guarded Terminals
Dual Terminal Markings
DC Control Option
through 180A
Wide Range of
Accessories
Top and Side
Mounting Auxiliary
Contacts
Timers
Latches
Surge Suppressors
Mechanical/Electrical
Interlocks

TABLE OF CONTENTS
Description

Page

Product Selection
Bulletin 100 Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
Bulletin 199 Wye-Delta Starter Kit . . . . . . . . . . . . . . . . . . . . . . . 3-9
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-48

Description

Page

Approximate Dimensions
Bulletin 100 Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-66
Bulletin 199 Wye-Delta Starter Kit. . . . . . . . . . . . . . . . . . . . . . 3-82
Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-154

Description
Bulletin 100 Modular Line of contactors, when combined with the Bulletin 193 SMP
or Bimetallic overload relays, auxiliary contacts, timers, interlocks, suppressors, and
DIN mounting rail provides a highly flexible grouping of world acceptable devices.

Conformity to Standards:

Approvals Pending:

IEC 947-4

DEMKO Denmark

BS 5424

NEMKO Netherlands

VDE 0660

SEMKO Sweden

IEC 947-4 Type 2 Co-ordination


(UL and ASTA Certified)

SETI Finland

Approvals:
CSA Certified (File No. LR1234)
UL Listed (File No. E3125;
Guide No. NLDX)
CE Marked (Per EU Low Voltage
Directive 73/23/EEC 93/68/EEC)

A-B EXPRESS
Fast Shipment Program
Fast Shipment of Bulletin 100 IEC
Contactors to satisfy your unexpected
demands.
Make your selections from any of the
Cat. Nos. printed in blue and identify
your order as

Your order must include:


Cat. No. of the contactor selected with
coil voltage code.
If required, Cat. No. of any
accessories.
If required, Cat. No. of replacement
coils or contact kits.

3-5

Bulletin 100

IEC Contactors
Product Selection
AC Operated Contactors

Fast Shipment Program Cat. Nos. are printed in blue.

Cat. No. 100-A09...A30

Cat. No. 100-A38...A75

Cat. No. 100-B110...B600

Cat. No. 104-A09...A30

Ratings (AC3, AC4)


kW (50 Hz)

HP (60 Hz)

Max.
Ie
(A)

220V

9
12
18
24
30
38
45
60
75
110
180
250
304
414
608

2.2
3
4
5.5
7.5
10
11
15
22
30
45
75
90
120
180

380V
415V 500V
4
5.5
7.5
11
15
18.5
22
30
37
55
90
132
160
220
315

5.5
7.5
11
15
18.5
22
30
37
45
75
110
160
200
280
445

Non-Reversing
Contactors

660V

115V

230V

200V

230V

460V

575V

Cat. No.

5.5
7.5
11
15
18.5
18.5
22
37
45
75
110
160
200
280
445

1/3
1/2
1
2
2
3
3
5
5

1
2
3
3
5
5
7-1/2
10
10

2
3
5
5
7-1/2
10
10
15
20
30
60
75
100
125
200

2
3
5
7-1/2
10
10
15
20
25
40
60
100
100
150
250

5
7-1/2
10
15
20
25
30
40
50
75
150
200
250
350
500

7-1/2
10
15
20
25
30
40
50
60
100
150
250
300
400
600

100-A09N 3
100-A12N 3
100-A18N 3
100-A24N 3
100-A30N 3
100-A38N 3
100-A45N 3
100-A60N 3
100-A75N 3
100-B110N 3
100-B180N 3
100-B250N 3
100-B300N 3
100-B400N 3
100-B600N 3

Reversing
Contactors

Cat. No.
104-A09N 3
104-A12N 3
104-A18N 3
104-A24N 3
104-A30N 3
104-A38N 3
104-A45N 3
104-A60N 3
104-A75N 3
104-B110N 3
104-B180N 3
104-B250N 3
104-B300N 3
104-B400N 3
104-B600N 3

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No. 100-A09N3
becomes Cat. No. 100-A09NJ3. For other voltages, consult Allen-Bradley Sales Office. Note: Coils below 110V are not available for 100-B400
and 100-B600 Contactors.

Voltage

24V

42V

50 Hz
60 Hz
50/60 Hz

K
J
KD

10048V 100V 110V 110V 120V 200V 208V 220V 240V 277V 347V 380V 415V 440V 480V 500V 550V 600V
Y
X
KH

KF

KF

KF

KE
D

KG

A
L

T
A

KK

N
E

B
G

4 main poles of same rating. Right hand pole is normally used as auxiliary.
Power Terminal Lugs Contactor Cat. Nos. 100-A09 through 100-A75 include wire terminal lugs. Contactor Cat. No. 100-B110 through
100-B600 have terminal pads with a bolt and nut for connection of bus bars or crimp type connectors. If wire lugs are required for these devices,
see Accessories on page 3-38.
Auxiliary Contacts Contactor Cat. Nos. 100-A09 through 100-A24 have a normally open auxiliary contact that has the same electrical ratings
as the main power contacts. All other sizes have a normally open auxiliary contact rated specifically for auxiliary circuits. Contactor Cat. Nos.
100-B400 and 100-B600 are furnished with one additional normally closed auxiliary contact. Example: Cat. No. 100-A09N 31.
Coils below 120V are not available for 400A through 600A devices due to high-inrush current, except for 110V 50Hz.

Accessories Page 3-38


Specifications Page 3-48
Approximate Dimensions Page 3-66

3-6

Prices Consult Sales Office or price list

Bulletin 100

IEC Contactors
Product Selection, Continued
DC Operated Contactors

Fast Shipment Program Cat. Nos. are printed in blue.

Pure DC design power to coil


Current
to Coil
Economized design power to coil terminals
Economised design power to coil terminals
Current to trigger circuit of economized
design (10mA at 24V DC)
Current to trigger circuit of economised
design (10mA at 24V DC)

Time

Typical Wiring Diagrams


(See Applicable Codes and Laws)
+
L1

88-226

+
L1

L2

L2

Control
Economized
DC Coil
+

Economised
DC Coil
To trigger circuit
(Must be same voltage as L1 and L2)

Pure DC Coil

Cat. No. 100-A09NZ...A30NZ

Pure DC Coil Contactors


Ratings (AC3, AC4)
kW (50 Hz)

HP (60 Hz)

Non-Reversing
Contactors

Reversing
Contactors

Max.
Ie
(A)

220V

380V
415V

500V

660V

115V

230V

200V

230V

460V

575V

2.2

5.5

5.5

1/3

7-1/2

100-A09NZ 3

104-A09NZ 3

12

5.5

7.5

7.5

1/2

7-1/2

10

100-A12NZ 3

104-A12NZ 3

18

7.5

11

11

10

15

100-A18NZ 3

104-A18NZ 3

24

5.5

11

15

15

7-1/2

15

20

100-A24NZ 3

104-A24NZ 3

30

7.5

15

18.5

18.5

7-1/2

10

20

25

100-A30NZ 3

104-A30NZ 3

38

10

18.5

22

18.5

10

10

25

30

100-A38NZ 3

104-A38NZ 3

45

11

22

30

22

7-1/2

10

15

30

40

100-A45NZ 3

104-A45NZ 3

60

15

30

37

37

10

15

20

40

50

100-A60NZ 3

104-A60NZ 3

75

22

37

45

45

10

20

25

50

60

100-A75NZ 3

104-A75NZ 3

110

30

55

75

75

30

40

75

100

100-B110NZ 3

104-B110NZ 3

Cat. No.

Cat. No.

DC Solid-State Economized Dual Wound Coil Contactors


Ratings (AC3, AC4)
kW (50 Hz)

Cat. No. 100-A38NE...A75NE

HP (60 Hz)

Non-Reversing
Contactors

Max.
Ie
(A)

220V

380V
415V

500V

660V

115V

230V

200V

230V

460V

575V

38

10

18.5

22

18.5

10

10

25

30

100-A38NE 3

45

11

22

30

22

7-1/2

10

15

30

40

100-A45NE 3

60

15

30

37

37

10

15

20

40

50

100-A60NE 3

75

22

37

45

45

10

20

25

50

60

100-A75NE 3

110

30

55

75

75

30

40

75

100

100-B110NE 3

180

45

90

110

110

60

60

150

150

100-B180NE 3

Cat. No.

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No. 100-A09NZ3
becomes Cat. No. 100-A09NZ123. For other voltages, consult Allen-Bradley Sales Office.
Voltage
Coil Code

Type

12V

24V

48V

64V

80V

115V

125V

230V

250V

Pure DC

12

24

48

64

80

01

03

23

25

Economized DC

24

48

01

23

4 main poles of same rating. Right hand pole is normally used as auxiliary.

Accessories Page 3-38


Specifications Page 3-48
Approximate Dimensions Page 3-82

Prices Consult Sales Office or price list

3-7

Bulletin 100

IEC Contactors
Product Selection, Continued
Welding Contactors

Cat. No. 100W-B180N2

Cat. No. 100W-B600N3

DESCRIPTION These devices are designed for use on applications where a contactor is used to isolate the primary of a welding
transformer from the supply power or where a contactor is used in series with the weld control SCR.
Normal applications require the contactor to carry the current without switching; therefore, the contactor has been assigned an
intermittent rating which represents the short term current the contactor can successfully carry without exceeding its thermal
capabilities.
Note: The average current during the operating cycle should not exceed the continuous rating of the contactor.
Continuous Rating

Intermittent Rating

Size

135A

2600A

270A

3000A

540A

3200A

Number of Poles

Cat. No.

2
3
2
3
2
3

100W-B180N2
100W-B180N3
100W-B300N2
100W-B300N3
100W-B600N2
100W-B600N3

Voltage Suffix Code

The Cat. No. as listed is incomplete. To complete the Cat. No., select a Voltage Suffix Code from the chart below and insert into the Cat. No..
Example: Cat. No. 100W-B180N3 becomes Cat. No. 100W-B180ND3. For other voltages, consult Allen-Bradley Sales Office.

Voltage

24V

48V

110V

120V

208V

220V

240V

277V

380V

415V

440V

480V

500V

600V

60 Hz
50 Hz

J
K

X
Y

L
A

A
T

G
B

When using Bulletin 199 terminal lug kits: Contactor Cat. Nos. 100W-B180N2 and 100W-B180N3 use Lug Kit Cat. No. 199-LF1, Contactor
Cat. Nos. 100W-B300N2 and 100W-B300N3 use Lug Kit Cat. No. 199-LG1, and Cat. Nos. 100W-B600N2 and 100W-B600N3 use Lug
Kit Cat. No. 199-LJ1.

Accessories Page 3-40


Specifications Page 3-48
Approximate Dimensions Page 3-72

3-8

Prices Consult Sales Office or price list

Bulletin 100

IEC Contactors
Product Selection, Continued
Wye-Delta Starter Kits
Wye-Delta Starter Kits have been designed to aid in the field
assembly of open transition Wye-Delta starters using Bulletin
100 Contactors. These kits include power wiring, shorting straps,
mechanical interlocks, incoming terminal blocks, and the
necessary mounting plate. Assembling a complete Wye-Delta
starter requires the use of the following additional components:
Contactors
Overload Relay
On-Delay Timer:
For 199-YD1 through 199-YD4, use Cat. No. 196-FTA
For 199-YD5 through 199-YD8, use Bulletin 700-F Control
Relay with Cat. No. 196-FTA
or
Use Cat. No. 700-FSD45G Electronic Timing Relay

Cat. No. 199-YD1

Cat. No. 199-YD7

Product Selection
Use the table below to select the proper Wye-Delta starter assembly kit for your application.
3 Ratings
kW (50 Hz)

Use with Cat. No. 100-

HP (60 Hz)

Delta

Wye

220V

380/
415V

500V

660V

200V

230V

460V

575V

M1

M2

S1

Cat. No.

4.0
5.5
7.5
11
11
15
22
30
37
45
80
110
140

7.5
11
15
18.5
22
30
37
55
63
90
150
220
257

11
15
18.5
22
30
37
45
75
80
110
180
280
315

11
15
18.5
25
30
37
45
75
80
110
180
280
315

5
5
7-1/2
7-1/2
10
15
20
30
40
60
75
125
150

5
7-1/2
10
10
15
20
25
40
50
60
100
150
200

10
15
20
25
30
40
50
75
100
150
225
350
400

15
20
25
30
40
50
60
100
125
150
250
400
450

A09
A12
A18
A24
A30
A38
A45
A60
A75
B110
B180
B250
B300

A09
A12
A18
A24
A30
A38
A45
A60
A75
B110
B180
B250
B300

A09
A09
A12
A12
A18
A24
A30
A38
A45
A75
B110
B180
B180

199-YD1
199-YD1
199-YD2
199-YD2
199-YD3
199-YD4
199-YD4
199-YD5
199-YD5
199-YD6
199-YD7
199-YD8
199-YD8

For use with AC operated contactors only.

Approximate Dimensions Page 3-82

Prices Consult Sales Office or price list

3-9

Bulletin 100L

Electrically Held Lighting Contactors


3

Bulletin 100L
Electrically Held
20A Rating
4, 8 and 12-Pole
Configurations
Open or Enclosed
CSA Certified, UL Listed

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11


Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38

Description

Page

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-11
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-73

Description
Bulletin 100 Lighting Contactors have been designed to control a variety of lighting
loads. The product offering includes 4, 8, and 12 pole contactors with or without
enclosures. The Bulletin 100 line of lighting contactors have been designed with a
20A rating for all popular lighting loads and other non-motor applications including
tungsten filament lighting loads, electric discharge (fluorescent) loads, electric
furnaces, and electric water heaters. In addition these contactors have been designed
to meet the requirements of both CSA and UL.

Conformity to Standards:

Approvals:

IEC 947-4

CE Marked (Per Low Voltage Directive


73/23/EEC 93/68/EEC)

Cat. No. of the contactor selected with


coil Voltage Suffix Code.

CSA Certified (File No. LR1234)

If required, Cat. No. of any


accessories.

CSA C22.2 No. 14


UL 508

UL Listed (File No. E125316;


Guide No. NLDX)

3-10

Your order must include:

Bulletin 100L

Electrically Held Lighting Contactors


Product Selection
Ratings
Max AC Volts
Poles to Load
Type of Load

Max (A)

1 for 1

3 for 3

20
15
20
15

277
347
277
347

480/277
600/347
480/277
600/347

30

600

600

Tungsten
Ballast
General Use
Resistance Heating
20A, 250V DC Max with 3 Poles in Series.
Type

Number of Poles

Cat. No.

4
8
12
4
8
12
4
8
12

100L-A20N4
100L-A20N8
100L-A20N12
100L-A20A4
100L-A20A8
100L-A20A12
100L-A20F4
100L-A20F8
100L-A20F12

Open

IP42 (Type 1)

IP66 (Type 3/4/12)

These contactors do not include an auxiliary hold-in contact. If a hold-in contact is required it can be ordered by adding a suffix -90 to the Cat.
No.Example: Cat. No. 100L-A20NJ4-90.

Voltage Suffix Code

The Cat. No. as listed is incomplete. To complete the Cat. No., select a Voltage Suffix Code from the chart below and insert into the Cat. No.
Cat. No. 100L-A20N4 becomes Cat. No. 100L-A20NJ4. For other voltages, consult Allen-Bradley Sales Office.

Voltage

24V

48V

110V

120V

208V

220V

240V

277V

347V

380V

415V

440V

480V

500V

600V

50 Hz
60 Hz

K
J

Y
X

A
L

T
A

KK

B
G

Typical Wiring Diagrams


(See Applicable Codes and Laws)
8 Poles
8 Poles

A1

4 Poles
4 Poles
1

5
L3

L1

3
L2

T1
2

T2
4

T3
6

T4
8

A1

L4

1
L1

3
L2

T1
2

T2
4

T3
6

A2

L4
T4
8

1
L1

3
L2

T1
2

T2
4

5
L3

L1

L2

L3

L4

T1

T2

T3

T4

A2

T4
8

A2

A1

7
L4

T3
6

A2

A1

12 Poles
12 Poles

7
L3

A1
5
L3

7
L4

L1

3
L2

L1

3
L2

5
L3

7
L4

T1
2

T2
4

T3
6

T4
8

T1
2

T2
4

T3
6

T4
8

A2

A2

Accessories Page 3-38


Approximate Dimensions Page 3-73

Prices Consult Sales Office or price list

3-11

Bulletin 105

IEC Reversing Starters


Enclosed Type
3

Bulletin 105
Selection of Metal
Enclosures
IP42 (Type 1) and
IP66 (Type 3/4/12)
Bimetallic Class 10
Overload Relays
SMP-1, SMP-2 or SMP-3
Solid-State Overload
Relays
Compact Design
Meets International
Standards

IP42 (Type 1) Enclosure


With Optional Control Circuit Transformer
For Rev-OFF Push Buttons and Pilot Lights

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13


Overload Relay Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38

Description

Page

Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-45
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-75

Description
Bulletin 105 enclosed starters utilize Bulletin 104 reversing contactors and Bulletin
193 bimetallic (Class 10) or Smart Motor Protection overload relays. Reversing
starters (9A through 300A) incorporate a dual interlock which provides both
mechanical and electrical interlocking within a single unit. The 400A and 600A
devices use a mechanical interlock plus normally closed auxiliaries to provide
electrical interlock protection.

Conformity to Standards:

Approvals:

IEC 947
VDE 0660

CE Marked
(Low Voltage Directive: 72/23/EEC,
93/68/EEC)

CSA 22.2

CSA Certified (File No. LR1234)

UL 508

UL Listed (File No. E3125)

A-B EXPRESS
Fast Shipment Program
Fast Shipment of Bulletin 105 IEC
Products to satisfy your unexpected
demands
Make your selections from any of the
Cat. Nos. printed in blue and identify
your order as

Your order must include:


Cat. No. of the reversing starter
selected.
Voltage Suffix Code.
Overload relay suffix code.
If required, factory installed
modifications suffix code.
If required, Cat. No. of any
accessories.

3-12

Bulletin 105

IEC Reversing Starters


Product Selection
Enclosed Type

Fast Shipment Program Cat. Nos. are printed in blue.

Ratings (AC3, AC4)


kW

IP42 (Type 1)
General Purpose
Sheet Metal Enclosure

HP
1

IP66 (Type 3/4/12)


Watertight, Dusttight
Sheet Metal Enclosure
Enclosure
Code

Enclosure
Code

Style

W/O
XFMR
Dim.

1/3

7-1/2

A08

A09

105-A09A3-

F08

F09

105-A09F3-

12

5.5

1/2

7-1/2

10

A08

A09

105-A12A3-

F08

F09

105-A12F3-

18

7.5

10

15

A08

A09

105-A18A3-

F08

F09

105-A18F3-

24

11

7-1/2

15

20

A08

A09

105-A24A3-

F08

F09

105-A24F3-

30

15

7-1/2

10

20

25

A09

A10

105-A30A3-

F09

F10

105-A30F3-

38

18.5

10

10

25

30

A09

A10

105-A38A3-

F09

F10

105-A38F3-

45

22

7-1/2

10

15

30

40

A09

A10

105-A45A3-

F09

F10

105-A45F3-

60

30

10

15

20

40

50

A10

A11

105-A60A3-

F10

F11

105-A60F3-

75

37

10

20

25

50

60

A10

A11

105-A75A3-

F10

F11

105-A75F3-

110

55

30

40

75

100

A11

A12

105-B110A3-

F11

F12

105-B110F3-

180

90

60

60

150

150

A12

A13

105-B180A3-

F12

F13

105-B180F3-

250

132

75

100

200

250

A13

A14

105-B250A3-

F13

F14

105-B250F3-

303

160

100

100

250

300

A13

A14

105-B300A3-

F13

F14

105-B300F3-

414

220

125

150

350

400

A13

A14

105-B400A3-

F13

F14

105-B400F3-

608

315

300

250

500

600

A14

A14

105-B600A3-

F14

F14

105-B600F3-

Max
Ie
(A)

W/O
With
380V/
XFMR XFMR
415V 115V 230V 200V 230V 460V 575V Style Dim.
Dim.

Cat. No.

With
XFMR
Dim.

Cat. No.

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No. 105-A09A3-
becomes Cat. No. 105-A09AB3-.
Voltage

Common Control
Separate Control

24

48

110

120

208

220

240

277

380

415

440

480

500

50 Hz

600

60 Hz

50 Hz

60 Hz

Overload Relay Code


The Cat. No. as listed is incomplete. Select an overload relay code from page 3-34 to complete the Cat. No.
When selecting a factory installed control circuit transformer (see Modifications page 3-45), use the Common Control Voltage Suffix Code to
denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No.
105-A09FB3--6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V
is desired, a second Voltage Suffix Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 105-A09FBJ3--6P
will have a transformer with a 480V primary/24V secondary and a 24V starter coil.
For single phase (1) applications, consult Allen-Bradley Sales Office for overload relay selection.

Overload Relay Selection Page 3-34


Accessories Page 3-38
Modifications Page 3-45
Approximate Dimensions Page 3-75

Prices Consult Sales Office or price list

3-13

Bulletin 105

IEC Reversing Starters


Open Type Eutectic Alloy Overload Relay
3

Bulletin 105
Open Type
Eutectic Alloy Overload
Relay Accepts Class 10,
20 or 30 Heater
Elements
Compact Design
Attached to a Common
Mounting Plate

Open Type With Eutectic Alloy Overload Relay

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15


Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38

Description

Page

Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-45
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-77

Description
Bulletin 105 enclosed starters utilize Bulletin 104 reversing contactors and a Bulletin
592 eutectic alloy overload relay on a common mounting plate. Reversing starters
(9A through 180A) incorporate a dual interlock which provides both mechanical and
electrical interlocking within a single unit.

Your order must include:


Conformity to Standards:
CSA 22.2

Cat. No. of the reversing starter


selected.

UL 508

Voltage Suffix Code.


Overload relay suffix code.

3-14

Bulletin 105

IEC Reversing Starters


Product Selection
Open Type Eutectic Alloy Overload Relay
Reversing Starters with AC Coils Starters require 3 overload heater elements. See page 1-202 for selection tables.
Ratings (AC3, AC4)
kW

HP

Open Type

Max
Ie
(A)

380V/415V

115V

230V

200V

230V

460V

575V

9
12
18
24
30
38
45
60
75
110

4
5.5
7.5
11
15
18.5
22
30
37
55

1/3
1/2
1
2
2
3
3
5
5

1
2
3
3
5
5
7-1/2
10
10

2
3
5
5
7-1/2
10
10
15
20
30

2
3
5
7-1/2
10
10
15
20
25
40

5
7-1/2
10
15
20
25
30
40
50
75

7-1/2
10
15
20
25
30
40
50
60
100

Cat. No.
105-A09NJOV
105-A12NJOV
105-A18NJOV
105-A24NJOV
105-A30NKOV
105-A38NCOV
105-A45NCOV
105-A60NCOV
105-A75NDOV
105-B110NDOV

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No. 105-A09NJOV
becomes Cat. No. 105-A09NDJOV.
Voltage
50 Hz
60 Hz
50 Hz
60 Hz

Common Control
Coil Voltage Suffix Code
Separate Control (without transformer)
Coil Voltage Suffix Code

24

48

110

120

208

220

240

277

380

415

440

480

500

600

K
J

Y
X

A
L

T
A

B
G

Reversing Starters with DC Coils Starters require 3 overload heater elements. See page 1-202 for selection tables.
Ratings (AC3, AC4)
kW

HP

Open Type

Max
Ie
(A)

380V/415V

115V

230V

200V

230V

460V

575V

9
12
18
24
30
38
45
60
75
110

4
5.5
7.5
11
15
18.5
22
30
37
55

1/3
1/2
1
2
2
3
3
5
5

1
2
3
3
5
5
7-1/2
10
10

2
3
5
5
7-1/2
10
10
15
20
30

2
3
5
7-1/2
10
10
15
20
25
40

5
7-1/2
10
15
20
25
30
40
50
75

7-1/2
10
15
20
25
30
40
50
60
100

Cat. No.
105-A09NZJOV
105-A12NZJOV
105-A18NZJOV
105-A24NZJOV
105-A30NZKOV
105-A38NZCOV
105-A45NZCOV
105-A60NZCOV
105-A75NZDOV
105-B110NZDOV

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a voltage code from the table below to complete the Cat. No. Example: Cat. No. 105-A09NZJOV
becomes Cat. No. 105-A09NZ24JOV.
Voltage

24V

115V

DC

24

01

Accessories Page 3-38


Modifications Page 3-45
Approximate Dimensions Page 3-77
Heater Element Selection Page 1-202

3-15

Prices Consult Sales Office or price list

Bulletin 106

IEC Reversing Combination Starters


Fusible Disconnect Type
3

Bulletin 106
Selection of Metal
Enclosures
IP42 (Type 1) and
IP66 (Type 3/4/12)
Bimetallic Class 10
Overload Relay
SMP-1, SMP-2 or SMP-3
Solid-State Overload
Relays
Compact Design
Meets International
Standards
Can Be Modified in the
Field

IP66 (Type 3/4/12) Enclosure


With Optional Control Circuit
Transformer Push Buttons
and Pilot Lights

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17


Overload Relay Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38

Description

Page

Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-45
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-75

Description
Bulletin 106 Combination starters utilize a Bulletin 104 reversing contactor, a Bulletin
193 bimetallic (Class 10) or Smart Motor Protection overload relays, and a Bulletin
194R rotary disconnect switch. Reversing starters (9A through 300A) incorporate a
dual interlock which provides both mechanical and electrical interlocking within a
single unit.

Conformity to Standards:

Approvals:

IEC 947

CSA Certified

VDE 0660

UL Listed

Your order must include:


Cat. No. of the reversing combination
starter selected.

CSA 22.2

Voltage Suffix Code.

UL 508

Overload relay suffix code.


If required, factory installed
modifications suffix code.
If required, Cat. No. of any
accessories.

3-16

Bulletin 106

IEC Reversing Combination Starters


Product Selection
Disconnect Type
Ratings (AC3, AC4)

IP42 (Type 1)
General Purpose
Sheet Metal Enclosure

IP66 (Type 3, 4, 12)


Watertight, Dusttight
Sheet Metal Enclosure

Style

With &
W/O
XFMR
Dim.

Cat. No.

Style

With &
W/O
XFMR
Dim.

Cat. No.

D
D
D
D
D
D
D
D
D
D
D
D

A10
A10
A10
A10
A10
A11
A11
A12
A12
A14
A14
A14

106-A09A
106-A12A
106-A24A
106-A30A
106-A45A
106-A60A
106-A75A
106-B110A
106-A180A
106-B180A
106-B250A
106-B300A

D
D
D
D
D
D
D
D
D
D
D
D

F10
F10
F10
F10
F10
F11
F11
F12
F12
F14
F14
F14

106-A09F
106-A12F
106-A24F
106-A30F
106-A45F
106-A60F
106-A75F
106-B110F
106-A180F
106-B180F
106-B250F
106-B300F

HP
kW

3
Max
380
Ie
(A) 415V 200V 230V 460V 575V
9
12
24
30
45
60
75
110
180
180
250
300

4
5.5
11
15
22
30
37
55
90
90
132
160

Fuse Clip
Rating
Amperes/
UL Class

2
2
5
7-1/2 30A/Class CC
3
3
7-1/2
10
30A/Class J
5
7-1/2
15
20
30A/Class J
7-1/2
10
20
25
60A/Class J
10
15
30
40
60A/Class J
15
20
40
50
100A/Class J
20
25
50
60
100A/Class J
30
40
75
100 200A/Class J
50
60
125
150 200A/Class J
60

150

400A/Class J
75
100
200
250 400A/Class J
100
100
250
300 400A/Class J

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No. 106-A09A
becomes Cat. No. 106-A09AB.
Voltage

Common Control
Separate Control

60 Hz

208V

230-240V

460-480V

575-600V

H
AD

A
AD

B
CD

C
CD

Overload Relay Code


The Cat. No. as listed is incomplete. Select an overload relay code from page 3-34.
When selecting a factory installed control circuit transformer (see Modifications page 3-45), use the Common Control Voltage Suffix Code to
denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No.
106-A09FB3-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V
is desired, a second Voltage Suffix Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 106-A09FBJ-6P
will have a transformer with a 480V primary/24V secondary and a 24V starter coil.

Overload Relay Selection Page 3-34


Accessories Page 3-38
Modifications Page 3-45
Approximate Dimensions Page 3-75

Prices Consult Sales Office or price list

3-17

Bulletin 109

IEC Non-Reversing Starters


Enclosed Type Molded Plastic
3a

Bulletin 109
An Enclosed Starter
Contains the Following
Components:

Type 1 With Start-Stop Push Buttons


and Reset
Cat. No. 109-A09B3-1

Bulletin 100 Contactor With a Bulletin


193 Solid-State Overload Relay.

Compact Design
Impact Resistant
Molded Enclosures
IP42 (Type 1) or IP66
(Type 4/4X/12)
Enclosure Ratings
Bimetallic Class 10
Overload Relays
SMP-1 or SMP-2
Solid-State Overload
Relays
Meets International
Standards

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19


Overload Relay Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38

Description

Page

Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-45
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-75

Description
Bulletin 109 enclosed starters are designed using Bulletin 100 contactors (9A through
24A) and Bulletin 193 bimetallic (Class 10) or Smart Motor Protection overload relays
in a molded enclosure. These molded enclosures are compact in design which is
essential where mounting space is a premium, yet they offer ample internal wiring
space.

A-B EXPRESS
Fast Shipment Program

Installation is made simple with features such as conduit knockouts, pilot device
knockouts and backed out terminal screws to reduce wiring time. The enclosure base
contains a molded 35mm DIN rail which makes mounting the starter into the enclosure
a snap.

Make your selections from any of the


Cat. Nos. printed in blue and identify
your order as

A variety of accessories are available to allow flexibility to configure the appropriate


starter to satisfy most application needs. These full voltage non-reversing starters
continue the Bulletin 100 tradition by complying to both domestic and international
standards.

Fast Shipment of Bulletin 109 IEC


Products to satisfy your unexpected
demands

Your order must include:


Cat. No. of the starter.
Voltage Suffix Code.

Conformity to Standards:

Approvals:

Overload relay suffix code.

IEC 947

If required, factory installed


modifications suffix code.

VDE 0660

CE Marked
(Per Low Voltage Directive
73/23/EEC 93/68/EEC)

UL 508

CSA Certified (File No. LR1234)


UL Listed (File No. E3125)

3-18

If required, Cat. No. of any


accessories.

Bulletin 109

IEC Non-Reversing Starters


Product Selection
Enclosed Type Molded Plastic

Fast Shipment Program Cat. Nos. are printed in blue.

Ratings (AC3, AC4)

kW

HP

3
Max
Ie
(A)
9
12
18
24

Enclosure
Code

Enclosure
Code

W/O
380V/
XFMR
415V 115V 230V 200V 230V 460V 575V Style Dim.
4
5.5
7.5
11

1/3
1/2
1
2

1
2
3
3

2
3
5
5

IP66 (Type 4, 4X, 12)


Watertight, Dusttight
Corrosion Resistant
Molded Plastic Enclosure

IP42 (Type 1)
General Purpose
Molded Plastic Enclosure

2
5
7-1/2
3
7-1/2 10
5
10
15
7-1/2 15
20

A
A
A
A

B01
B01
B02
B02

W/O
XFMR
Style Dim.

Cat. No.
109-A09B3-
109-A12B3-
109-A18B3-
109-A24B3-

A
A
A
A

K01
K01
K02
K02

Cat. No.
109-A09K3-
109-A12K3-
109-A18K3-
109-A24K3-

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No. 109-A09B3-
becomes Cat. No. 109-A09BA3-.
Voltage

Common Control
Separate Control

50 Hz
60 Hz
50 Hz
60 Hz

24V

48V

K
J

Y
X

110V 120V 208V 220V 240V 277V 380V 415V 440V 480V 500V 600V

A
L

T
A

B
G

Overload Relay Code


The Cat. No. as listed is incomplete. Select an overload relay code from page 3-34 to complete the Cat. No.

For single phase (1) applications, consult Allen-Bradley Sales Office for overload relay selection.
For Bulletin 109 with SMP-2 solid-state overload relays, the enclosure code dimension changes to B02.
For Bulletin 109 with SMP-2 solid-state overload relays, the enclosure code dimension changes to K02.

Overload Relay Selection Page 3-34


Accessories Page 3-38
Modifications Page 3-45
Approximate Dimensions Page 3-75

Prices Consult Sales Office or price list

3-19

Bulletin 109

IEC Non-Reversing Starters


Enclosed Type Sheet Metal
3

Bulletin 109
Selection of Metal
Enclosures
IP42 (Type 1) and
IP66 (Type 3/4/12)
Compact Design
Bimetallic Class 10
Overload Relays
SMP-1, SMP-2 or SMP-3
Solid-State Overload
Relays
Meets International
Standards
Type 1 Enclosure
With Push Button and Pilot Light

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21


Overload Relay Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38

Description

Page

Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-44
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-75

Description
Bulletin 109 enclosed starters are designed using Bulletin 100 contactors (9A through
608A) and Bulletin 193 bimetallic (Class 10) or Smart Motor Protection overload
relays in a metal enclosure.

Conformity to Standards:

Approvals:

IEC 947

(Consult factory for all other approvals)

VDE 0660
CSA 22.2

CE Marked
(Per Low Voltage Directive
73/23/EEC 93/68/EEC)

UL 508

CSA Certified (File No. LR1234)

A-B EXPRESS
Fast Shipment Program
Fast Shipment of Bulletin 109 IEC
Products to satisfy your unexpected
demands
Make your selections from any of the
Cat. Nos. printed in blue and identify
your order as

UL Listed (File No. E3125)

Your order must include:


Cat. No. of the starter selected.
Voltage Suffix Code.
Overload relay code suffix.
If required, factory installed
modifications suffix code.
If required, Cat. No. of any
accessories.

3-20

Bulletin 109

IEC Non-Reversing Starters


Product Selection
Enclosed Type Sheet Metal

Fast Shipment Program Cat. Nos. are printed in blue.

Ratings (AC3, AC4)


kW

HP
1

3
Max
Ie
(A)

IP42 (Type 1)
General Purpose
Sheet Metal Enclosure
3

IP66 (Type 3, 4, 12)


Watertight, Dusttight
Sheet Metal Enclosure
Enclosure Code

Enclosure Code

W/O
380V/
XFMR
415V 115V 230V 200V 230V 460V 575V Style Dim.

With
XFMR
Dim.

Cat. No.

Style

W/O
XFMR
Dim.

With
XFMR
Dim.

Cat. No.

1/3

7-1/2

A02

A03

109-A09A3-

F02

F03

109-A09F3-

12

5.5

1/2

7-1/2

10

A02

A03

109-A12A3-

F02

F03

109-A12F3-

18

7.5

10

15

A02

A03

109-A18A3-

F02

F03

109-A18F3-

24

11

7-1/2

15

20

A02

A03

109-A24A3-

F02

F03

109-A24F3-

30

15

7-1/2

10

20

25

A03

A09

109-A30A3-

F03

F09

109-A30F3-

38

18.5

10

10

25

30

A03

A09

109-A38A3-

F03

F09

109-A38F3-

45

22

7-1/2

10

15

30

40

A03

A09

109-A45A3-

F03

F09

109-A45F3-

60

30

10

15

20

40

50

A04

A10

109-A60A3-

F04

F10

109-A60F3-

75

37

10

20

25

50

60

A04

A10

109-A75A3-

F04

F10

109-A75F3-

110

55

30

40

75

100

A05

A11

109-B110A3-

F05

F11

109-B110F3-

180

90

60

60

150

150

A06

A12

109-B180A3-

F12

F12

109-B180F3-

250

132

75

100

200

250

A13

A13

109-B250A3-

F13

F13

109-B250F3-

303

160

100

100

250

300

A13

A13

109-B300A3-

F13

F13

109-B300F3-

414

220

125

150

350

400

A13

A13

109-B400A3-

F13

F13

109-B400F3-

608

315

300

250

500

600

A14

A14

109-B600A3-

F14

F14

109-B600F3-

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No. 109-A09A3-
becomes Cat. No.109-A09AB3-.
Voltage

Common Control
Separate Control (without transformer)

24V

48V

110V

120V

208V

220V

240V

277V

380V

415V

440V

480V

500V

50 Hz

600V

60 Hz

50 Hz

60 Hz

Overload Relay Code


The Cat. No. as listed is incomplete. Select an overload relay code from page 3-34.
For single phase (1) applications, consult Allen-Bradley Sales Office for overload relay selection.
When selecting a factory installed control circuit transformer (see Modifications page 3-44), use the Common Control Voltage Suffix Code to
denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No.
109-A09FB3--6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V
is desired, a second Voltage Suffix Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 109-A09FBJ3--6P
will have a transformer with a 480V primary/24V secondary and a 24V starter coil.

Overload Relay Selection Page 3-34


Accessories Page 3-38
Modifications Page 3-44

Prices Consult Sales Office or price list

3-21

Bulletin 109

IEC Non-Reversing Starters


Open Type Eutectic Alloy Overload Relay
3

Bulletin 109
Open Type
Eutectic Alloy Overload
Relay Accepts Class 10,
20 or 30 Heater
Elements
Compact Design
Attached to a Common
Mounting Plate

Open Type With Eutectic Alloy Overload Relay

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23


Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38

Description

Page

Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-44
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-77

Description
Bulletin 109 open style starters utilize Bulletin 100 contactors and Bulletin 592 eutectic
alloy overload relays on a common mounting plate.

Your order must include:


Conformity to Standards:

Cat. No. of the starter selected.

CSA 22.2

Voltage Suffix Code.

UL508

3-22

Overload relay suffix code.

Bulletin 109

IEC Non-Reversing Starters


Product Selection
Open Type Eutectic Alloy Overload Relay
Starters with AC Coils Starters require 3 overload heater elements. See page 1-202 for selection tables.
Ratings (AC3, AC4)
kW

HP

Open Type

Max
Ie
(A)

380V/415V

115V

230V

200V

230V

460V

575V

Cat. No.

1/3

7-1/2

109-A09NJOV

12

5.5

1/2

7-1/2

10

109-A12NJOV

18

7.5

10

15

109-A18NJOV

24

11

7-1/2

15

20

109-A24NJOV

30

15

7-1/2

10

20

25

109-A30NKOV

38

18.5

10

10

25

30

109-A38NCOV

45

22

7-1/2

10

15

30

40

109-A45NCOV

60

30

10

15

20

40

50

109-A60NCOV

75

37

10

20

25

50

60

109-A75NDOV

110

55

30

40

75

100

109-B110NDOV

180

90

60

60

150

150

109-B180NTP2

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No. 109-A09NJOV
becomes Cat. No. 109-A09NDJOV.
Voltage

Common Control
Coil Voltage Suffix Code
Separate Control (without transformer)
Coil Voltage Suffix Code

24V

48V

110V

120V

208V

220V

240V

277V

380V

415V

440V

480V

500V

50 Hz

600V

60 Hz

50 Hz

60 Hz

Starters with DC Coils Starters require 3 overload heater elements. See page 1-202 for selection tables.
Ratings (AC3, AC4)
kW

Open Type

HP

Max
Ie
(A)

380V/415V

115V

230V

200V

230V

460V

575V

1/3

7-1/2

109-A09NZJOV

12

5.5

1/2

7-1/2

10

109-A12NZJOV

18

7.5

10

15

109-A18NZJOV

24

11

7-1/2

15

20

109-A24NZJOV

30

15

7-1/2

10

20

25

109-A30NZKOV

38

18.5

10

10

25

30

109-A38NZCOV

45

22

7-1/2

10

15

30

40

109-A45NZCOV

60

30

10

15

20

40

50

109-A60NZCOV

75

37

10

20

25

50

60

109-A75NZDOV

110

55

30

40

75

100

109-B110NZDOV

180

90

60

60

150

150

109-B180NZTP2

3
Cat. No

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No.
109-A09NZJOV becomes Cat. No. 109-A09NZ24JOV.
Voltage

24V

115V

DC

24

01

Accessories Page 3-38


Modifications Page 3-44
Approximate Dimensions Page 3-77
Heater Element Selection Page 1-202

Prices Consult Sales Office or price list

3-23

Bulletin 112

IEC Combination Starters


Fusible Disconnect Type
3

Bulletin 112
Compact Design
Can Be Modified in
the Field
Selection of Enclosures
IP42 (Type 1) and
IP66 (Type 3/4/12)
Bimetallic Class 10
Overload Relays
SMP-1, SMP-2 or SMP-3
Solid-State Overload
Relays

IP66 (Type 3/4/12) Enclosure With


Optional START-STOP Push Button and External Reset

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25


Overload Relay Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38

Description

Page

Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-46
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-75

Description
Bulletin 112 is the first true IEC combination starter on the market, in that the
enclosure and components have been designed to the specific IEC standard
requirements. The Bulletin 112 combination starter consists of a Bulletin 100
Contactor, Bulletin 193 bimetallic (Class 10) or Smart Motor Protection overload relay
and Bulletin 194R fused disconnect switch installed in a common enclosure. These
full voltage combination starters are designed to provide the disconnecting means,
short circuit protection (with suitable fuses), control and overload protection for three
phase squirrel-cage motors.

Conformity to Standards:

Approvals:

IEC 947

(consult factory for all other approvals)

VDE 0660
CSA 22.2

CE Marked
(Per Low Voltage Directive
73/23/EEC 93/68/EEC)

UL 508

CSA Certified (File No. LR1234)


UL Listed (File No. E125316)

A-B EXPRESS
Fast Shipment Program
Fast shipment of Bulletin 112 IEC
Products to satisfy your unexpected
demands.
Make your selections from any of the
Cat. Nos. printed in blue and identify
your order as

Your order must include:


Cat. No. of the combination starter
selected.
Voltage Suffix Code.
Overload relay suffix code.
If required, factory installed
modifications suffix code.
If required, Cat. No. of any
accessories.

3-24

Bulletin 112

IEC Combination Starters


Product Selection
Fusible Disconnect Type

Fast Shipment Program Cat. Nos. are printed in blue.

Ratings (AC3, AC4)


HP
3
Max
Ie
(A)

200V

230V

460V

9
12
24
30
45
60
75
110
180
180
250
300

2
3
5
7-1/2
10
15
20
30
50
60
75
100

2
3
7-1/2
10
15
20
25
40
60

100
100

5
7-1/2
15
20
30
40
50
75
125
150
200
250

IP42 (Type 1)
General Purpose
Sheet Metal Enclosure

IP66 (Type 3/4/12)


Watertight, Dusttight
Sheet Metal Enclosure

Cat. No.

Style

With &
W/O
XFMR
Dim.

Cat. No.

112-A09A
112-A12A
112-A24A
112-A30A
112-A45A
112-A60A
112-A75A
112-B110A
112-A180A
112-B180A
112-B250A
112-B300A

D
D
D
D
D
D
D
D
D
D
D
D

F04
F04
F04
F10
F10
F11
F11
F12
F12
F13
F13
F13

112-A09F
112-A12F
112-A24F
112-A30F
112-A45F
112-A60F
112-A75F
112-B110F
112-A180F
112-B180F
112-B250F
112-B300F

575V

Fuse Clip
Rating
Amperes/
UL Class

Style

With &
W/O
XFMR
Dim.

7-1/2
10
20
25
40
50
60
100
150

250
300

30A/Class CC
30A/Class J
30A/Class J
60A/Class J
60A/Class J
100A/Class J
100A/Class J
200A/Class J
200A/Class J
400A/Class J
400A/Class J
400A/Class J

D
D
D
D
D
D
D
D
D
D
D
D

A04
A04
A04
A10
A10
A11
A11
A12
A12
A13
A13
A13

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No. 112-A09A
becomes Cat. No. 112-A09AB.
Voltage

Common Control
Separate Control

60 Hz

208V

230-240V

460-480V

575-600V

H
AD

A
AD

B
CD

C
CD

Overload Relay Code


The Cat. No. as listed is incomplete. Select an overload relay code from page 3-34 to complete the Cat. No.
When selecting a factory installed control circuit transformer (see Modifications page 3-44), use the Common Control Voltage Suffix Code to
denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No.
112-A09FB3--6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V
is desired, a second Voltage Suffix Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 112-A09FBJ3--6P
will have a transformer with a 480V primary/24V secondary and a 24V starter coil.

Overload Relay Selection Page 3-34


Accessories Page 3-38
Modifications Page 3-44
Approximate Dimensions Page 3-75

Prices Consult Sales Office or price list

3-25

Bulletin 113

IEC Combination Starters


Circuit Breaker Type
3

Bulletin 113
Compact Design
Can Be Modified in the
Field
Selection of Enclosures
IP42 (Type 1)
IP66 (Type 3/4/12)
Bimetallic Class 10
Overload Relays
SMP-1, SMP-2 or SMP-3
Solid-State Overload
Relays

IP66 (Type 3/4/12) Enclosure With Optional Start-Stop Push Button,


Pilot Light and Control Circuit Transformer

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27


Overload Relay Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38

Description

Page

Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-46
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-75

Description
Bulletin 113 combination starter consists of a Bulletin 100 contactor, Bulletin 193
bimetallic (Class 10) or Smart Motor Protection overload relay and a motor circuit
protector installed in a common enclosure. These full voltage combination starters
are designed to provide the disconnecting means, short circuit protection, control
and overload protection for three phase squirrel-cage motors.

Conformity to Standards:

Approvals:

IEC 947

CSA Certified

VDE 0660

UL Listed

Your order must include:


Cat. No. of the combination starter
selected.

CSA 22.2

Voltage Suffix Code.

UL 508

Overload relay suffix code.


If required, factory installed
modifications suffix code.
If required, Cat. No. of any
accessories.

3-26

Bulletin 113

IEC Combination Starters


Product Selection
Circuit Breaker Type
Ratings (AC3, AC4)
IP42 (Type 1)
General Purpose
Sheet Metal Enclosure

HP
3
Max
Ie
(A)

24

30
45

60
75
110

180

250
300

200V

230V

460V

575V

Style

With & W/O


XFMR Dim.

IP66 (Type 3/4/12)


Watertight, Dusttight
Sheet Metal Enclosure

Cat. No.

Style

With & W/O


XFMR Dim.

Cat. No.

1/2

1/2

3/41

3/41-1/2

A04

113-A24A-36

F04

113-A24F-36

3/41

3/41

1-1/23

23

A04

113-A24A-38

F04

113-A24F-38

1-1/23

1-1/23

57-1/2

510

A04

113-A24A-41

F04

113-A24F-41

57-1/2

1015

1520

A04

113-A24A-43

F04

113-A24F-43

7-1/2

10

20

25

A10

113-A30A-44

F10

113-A30F-44

10

25

30

A10

113-A45A-45

F10

113-A45F-45

15

30

A10

113-A45A-45X

F10

113-A45F-45X

40

A11

113-A45A-46

F10

113-A45F-46

15

20

40

50

A11

113-A60A-47

F11

113-A60F-47

20

25

50

60

A11

113-A75A-48

F11

113-A75F-48

25

30

60

75

A12

113-B110A-49

F12

113-B110F-49

30

40

75

100

A12

113-B110A-50

F12

113-B110F-50

40

50

100

125

A13

113-B180A-51

F13

113-B180F-51

50

60

125

150

A12

113-B180A-52

F12

113-B180F-52

60

150

A12

113-B180A-52X

F13

113-B180F-52X

75

200

A13

113-B250A-54

F13

113-B250F-54

75

100

200

250

A13

113-B250A-56

F13

113-B250F-56

100

250

300

A13

113-B300A-57

F13

113-B300F-57

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No. 113-A24A-33
becomes Cat. No. 113-A24AB-33.
Voltage

208V

Common Control

60 Hz

Separate Control

230-240V

460-480V

575-600V

HD

AD

BD

CD

Overload Relay Code


The Cat. No. as listed is incomplete. Select an overload relay code from page 3-34.

For design E motor applications, consult the factory.


For horsepower ratings less than those shown, consult the factory.
For 575V applications, the dimension code is A11.
For 575V applications, the dimension code is F11.
When selecting a factory installed control circuit transformer (see Modifications page 3-46), use the Common Control Voltage Suffix Code to
denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No.
113-A24FB3-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V
is desired, a second Voltage Suffix Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 113-A24FBJ-6P
will have a transformer with a 480V primary/24V secondary and a 24V starter coil.

Overload Relay Selection Page 3-34


Accessories Page 3-38
Modifications Page 3-44
Approximate Dimensions Page 3-75

Prices Consult Sales Office or price list

3-27

Bulletin 120E

IEC Multi-Speed Starters Two-Speed Separate Winding


Two-Speed Separate Winding
3

Bulletin 120E

Bulletin 120E, 45 Amp


Type 12 Enclosure and Cover Controls

Bulletin 120E, 45 Amp


Type 12 Enclosure and Cover Controls

Compact Design
Selection of Enclosures
IP42 (Type 1) and
IP66 (Type 3/4/12)
Bimetallic Class 10
Overload Relays
SMP-1, SMP-2 or SMP-3
Solid-State Overload
Relays

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29


Overload Relay Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38

Description

Page

Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-44
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-75

Description
Bulletin 120E multi-speed starters are designed to control two speed, separate
winding AC squirrel cage induction motors. These starters are available for constant
torque, variable torque or constant horsepower three phase motors. Multi-speed
motors are commonly used on machine tools, fans, blowers, pumps, conveyors and
many other types of equipment.
Bulletin 120E multi-speed motor starters utilize Bulletin 100 contactors and Bulletin
193 bimetallic (Class 10) or Smart Motor Protection overload relays. A wide variety
of factory and field installed options are available.
For two speed consequent pole motor starters, consult Allen-Bradley Sales Office.

A-B EXPRESS
Fast Shipment Program
Fast shipment of Bulletin 120E IEC
Products to satisfy your unexpected
demands.
Make your selections from any of the
Cat. Nos. printed in blue and identify
your order as

Constant Torque Constant torque motors will supply a constant torque at each
speed while the horsepower rating will vary directly with the speed. Typical
applications include conveyors, compressors, hoists, mixers and milling machines.
Variable Torque Variable torque motors have horsepower ratings that vary as a
square of the speed and have torque ratings that vary directly with the speed. Typical
applications include centrifugal pumps and fans.

Your order must include:

Constant Horsepower Constant horsepower motors have the same horsepower


rating at each speed while the torque varies inversely to the speed. Typical
applications include mixer, milling machines and cranes.

Cat. No. of the multi-speed starter


selected.

Conformity to Standards:

If required, factory installed


modifications suffix code.

Approvals:

IEC 947

CSA Certified (File No. LR1234)

VDE 0660

UL Listed (File No. E3125)

CSA 22.2
UL 508

3-28

Voltage Suffix Code.

If required, Cat. No. of any


accessories.

Bulletin 120E

IEC Multi-Speed Starters


Product Selection
Enclosed Type

Fast Shipment Program Cat. Nos. are printed in blue.

2 Speed Separate Winding, Constant or Variable Torque (Constant HorsepowerConsult Allen-Bradley Sales Office.)
Ratings (AC3, AC4)
kW

IP42 (Type 1)
General Purpose
Sheet Metal Enclosure

HP
1

IP66 (Type 3/4/12)


Watertight, Dusttight
Sheet Metal Enclosure
Enclosure
Code

Enclosure
Code

W/O
With
Max
XFMR XFMR
Ie 380V/
(A) 415V 115V 230V 200V 230V 460V 575V Style Dim. Dim.

Cat. No.

W/O With
XFMR XFMR
Style Dim. Dim.

Cat. No.

A09

120E-A09A3--

F08

F09

120E-A09F3--

A08

A09

120E-A12A3--

F08

F09

120E-A12F3--

A08

A09

120E-A18A3--

F08

F09

120E-A18F3--

A08

A09

120E-A24A3--

F08

F09

120E-A24F3--

A09

A10

120E-A30A3--

F09

F10

120E-A30F3--

30

A09

A10

120E-A38A3--

F09

F10

120E-A38F3--

30

40

A09

A10

120E-A45A3--

F09

F10

120E-A45F3--

20

40

50

A10

A11

120E-A60A3--

F10

F11

120E-A60F3--

20

25

50

60

A10

A11

120E-A75A3--

F10

F11

120E-A75F3--

30

40

75

100

A11

A12

120E-B110A3--

F11

F12

120E-B110F3--

60

60

150

150

A12

A13

120E-B180A3--

F12

F13

120E-B180F3--

132

75

100

200

250

A13

A14

120E-B250A3--

F13

F14

120E-B250F3--

303

160

100

100

250

300

A13

A14

120E-B300A3--

F13

F14

120E-B300F3--

414

220

125

150

350

400

A13

A14

120E-B400A3--

F13

F14

120E-B400F3--

608

315

300

250

500

600

A14

A14

120E-B600A3--

F14

F14

120E-B600F3--

1/3

12

5.5

1/2

18

7.5

24

11

30

15

38

18.5

45

7-1/2

7-1/2

10

10

15

7-1/2

15

20

7-1/2

10

20

25

10

10

25

22

7-1/2

10

15

60

30

10

15

75

37

10

110

55

180

90

250

A08

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No.
120E-A09A3-- becomes Cat. No. 120E-A09AB3--.
Voltage

Common Control
Separate Control

24V

48V

110V

120V

208V

220V

240V

277V

380V

415V

440V

480V

500V

50 Hz

600V

60 Hz

50 Hz

60 Hz

- Overload Relay Code


The Cat. No. as listed is incomplete. Select (2) overload relay codes from page 3-34.The first code will denote the high speed overload relay,
and the second code will denote the low speed overload relay.
For single phase (1) applications, consult Allen-Bradley Sales Office for overload relay selection.
When selecting a factory installed control circuit transformer (see Modifications page 3-44), use the Common Control Voltage Suffix Code to
denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No.
120E-A09FB3--6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V
is desired, a second Voltage Suffix Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No.
120E-A09FBJ3--6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.

Overload Relay Selections Page 3-34


Accessories Page 3-38
Modifications Page 3-44
Approximate Dimensions Page 3-75

Prices Consult Sales Office or price list

3-29

Bulletin 132

IEC Pump Control Panels


Fusible Disconnect Type
3

Bulletin 132
IP32 (Type 3R)
Bimetallic Class 10
Overload Relays
SMP-1, SMP-2 or SMP-3
Solid-State Overload
Relays
Enclosure with Extra
Panel Space for
Mounting Accessory
Devices
IP32 (Type 3R) Oversized Enclosure with
Start Push Button and Selector Switch as Standard

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-31


Overload Relay Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38

Description

Page

Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-44
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-75

Description
Bulletin 132 pump control panels are specifically designed for irrigation and similar
outdoor pumping applications.
The pump control panel includes a Bulletin194R IEC fusible rotary disconnect switch,
a Bulletin 100 IEC contactor, a Bulletin 193 bimetallic overload relay or Smart Motor
Protection overload relays and a HAND-OFF-AUTO selector switch and a START
button.
Bulletin 132 includes an IP32 (Type 3R) weather-resistant enclosure with a rugged,
outdoor finish and brackets for pole or cross bar mounting. Conduit knockouts are
located at the bottom of the enclosure. Padlock provisions are furnished on the door
latches and the disconnect handle (both the ON and OFF positions).

Your order must include:


Conformity to Standards:

Approvals:

Cat. No. of the pump control panel.

UL 508

UL Listed

Voltage Code Suffix.


Overload relay code suffix.
If required, factory installed
modifications code suffix.
If required, Cat. No. of any
accessories.

3-30

Bulletin 132

IEC Pump Control Panels


Product Selection
Fusible Disconnect Type
Ratings (AC3, AC4)
kW

Horsepower

Max.
Ie
(A)

380/415V

200V

230V

460V

575V

Style

Pin

Fuse Clip Rating


Amperes/UL Class

9
12
24
30
45
60
75
110
180
180
250

4
5.5
11
15
22
30
37
55
90
90
132

2
3
5
7.5
10
15
20
30
50
60
75

2
3
7.5
10
15
20
25
40
60

100

5
7.5
15
20
30
40
50
75
126
150
200

7.5
10
20
25
40
50
60
100
150

250

F
F
F
F
F
F
F
F
F
F
F

F01
F01
F01
F01
F01
F02
F02
F03
F04
F04
F04

30A/Class CC
30A/Class J
30A/Class J
60A/Class J
60A/Class J
100A/Class J
100A/Class J
200A/Class J
200A/Class J
400A/Class J
400A/Class J

Enclosure Code

IP32 (Type 3R)


Sleet Resistant, Outdoor
Sheet Metal Enclosure
Cat. No.

132-A09M
132-A12M
132-A24M
132-A30M
132-A45M
132-A60M
132-A75M
132-B110M
132-A180M
132-B180M
132-B250M

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No.
Voltage

Common Control Coil Voltage Suffix Code


120V Separate Control (without transformer) Coil Voltage Suffix Code

208V

230-240V

460-480V

575-600V

H
AD

A
AD

B
CD

C
CD

60 Hz

Overload Relay Code


The Cat. No. as listed is incomplete. Select an overload relay code from page 3-34.
When selecting a factory installed control circuit transformer (see Modifications page 3-44), use the Common Control Voltage Suffix Code to
denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No.
132-A09MB-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V
is desired, a second Voltage Suffix Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 132-A09MBJ-6P
will have a transformer with a 480V primary/24V secondary and a 24V starter coil.

Overload Relay Selection Page 3-34


Accessories Page 3-38
Modifications Page 3-44
Approximate Dimensions Page 3-75

Prices Consult Sales Office or price list

3-31

Bulletin 133

IEC Pump Control Panels


Circuit Breaker Type
3

Bulletin 133
IP32 (Type 3R)
Bimetallic Class 10
Overload Relays
SMP-1, SMP-2 or SMP-3
Solid-State Overload
Relays
Enclosure with Extra
Panel Space for
Mounting Accessory
Devices
IP32 (Type 3R) Oversized Enclosure With
Start Push Button and
Selector Switch as Standard

TABLE OF CONTENTS
Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-33


Overload Relay Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38

Description

Page

Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-44
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-75

Description
Bulletin 133 pump control panels are specifically designed for irrigation and similar
outdoor pumping applications.
The pump control panel includes a motor circuit protector, a Bulletin 100 IEC
contactor, a Bulletin 193 motor protection overload relay (bimetallic or smart motor
protection) and a HAND-OFF-AUTO selector switch and a START button.
Bulletin 133 includes an IP32 (Type 3R) weather-resistant enclosure with a rugged,
outdoor finish and brackets for pole or cross bar mounting. Conduit knockouts are
located at the bottom of the enclosure. Padlock provisions are furnished on the door
latches and the disconnect handle (both the ON and OFF positions).

Your order must include:


Conformity to Standards:

Approvals:

Cat. No. of the pump control panel.

UL 508

UL Listed

Voltage Code Suffix.


Overload relay code suffix.
If required, factory installed
modifications code suffix.
If required, Cat. No. of any
accessories.

3-32

Bulletin 133

IEC Pump Control Panels


Product Selection
Circuit Breaker Type
Ratings (AC3, AC4)
HP
Max.
Ie
(A)
24
30
45
60
75
110
180
250

3
200V
1/2
3/41
1-1/23
5
7-1/2
10

15
20
25
30
40
50
60

75

230V
1/2
3/41
1-1/23
57-1/2
10

15

20
25
30
40
50
60

75
100

Enclosure Code
460V
3/41
1-1/23
57-1/2
1015
20
25
30

40
50
60
75
100
125
150

200

575V
3/41-1/2
23
510
1520
25
30

40
50
60
75
100
125
150

200
250

Style
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F

Dim.
F01
F01
F01
F01
F01
F01
F01
F01
F02
F02
F03
F03
F04
F04
F04
F04
F04

IP32 (Type 3R)


Sleet Resistant, Outdoor
Sheet Metal Enclosure
Cat. No.
133-A24M-36
133-A24M-38
133-A24M-41
133-A24M-43
133-A30M-44
133-A45M-45
133-A45M-45X
133-A45M-46
133-A60M-47
133-A75M-48
133-B110M-49
133-B110M-50
133-B180M-51
133-B180M-52
133-B180M-52X
133-B250M-54
133-B250M-56

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No. 133-A09M
becomes Cat. No. 133-A09MB.

Voltage
Common Control Coil Voltage Suffix Code
120V Separate Control (without transformer) Coil Voltage Suffix Code

60 Hz

208V
H
AD

230-240V
A
AD

460-480V
B
CD

575-600V
C
CD

Overload Relay Code


The Cat. No. as listed is incomplete. Select an overload relay code from page 3-34.
For design E motor applications, consult the factory.
For horsepower ratings less than those shown, consult the factory.
When selecting a factory installed control circuit transformer (see Modifications page 3-44), use the Common Control Voltage Suffix Code to
denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No.
133-A24MB-38-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than
120V is desired, a second Voltage Suffix Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No.
133-A24MBJ-38-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.

Overload Relay Selection Page 3-34


Accessories Page 3-38
Modifications Page 3-44
Approximate Dimensions Page 3-75

Prices Consult Sales Office or price list

3-33

Bulletin 100 Line

Overload Relay Code Selection


Overload Relay Selection
3

SMP-1 Overload Relay for 3 Applications: Phase Loss Protection, Class 10 or 20


For Use with Bulletin
105, 106, 109, 112, 113, 120E, 132 and 133

A30

A24

A18

A75

A60

A12

A45

Full Load
Current Adjustment
Range (A)

3 Overload
Relay Code
Manual Reset

0.1.32
0.321.0
1.02.9
1.65.0
3.712
1232
1238
1445
2375
66110
57180
96300
128400
200630

A1A
A1C
A1D
A1E
A1F
A1H
A1H
A1J
A1K
A1L
A1M
A1N
A1P
A1R
XXX

A09

A38

B110
B180
B250 and B300
B400
B600
All Sizes No overload relay

3 Overload
Relay Code
Auto/Manual Reset

A4A
A4C
A4D
A4E
A4F
A4H
A4H
A4J
A4K
A4L
A4M
A4N
A4P
A4R
XXX

Starter Cat. Nos. listed have Class 10 overload relays. To order Class 20 overload relays, change the overload relay from A1_ to A2_. Example:
Cat. No. 105-A09AB3-A1A becomes Cat. No. 105-A09AB3-A2A.
Starter Cat. Nos. listed have Class 10 overload relays. To order Class 20 overload relays, change the overload relay from A4_ to A5_. Example:
Cat. No. 105-A09AB3-A4A becomes Cat. No. 105-A09AB3-A5A.

SMP-1 Overload Relay for 1 Applications: Phase Loss Protection, Class 10 or 20


For Use with Bulletin
105, 106, 109, 112, 113, 120E, 132 and 133
A30

A24

A18

A12

A45
A75

Full Load
Current Adjustment
Range (A)

1 Overload
Relay Code
Manual Reset

2.7
515
1232

S1A
S1B
S1C

S4A
S4B
S4C

A09

A38

A60

1 Overload
Relay Code
Auto/Manual Reset

515

S1B

S4B

1238

S1E

S4E

1445
2375

S1F
S1G

S1F
S1G

Starter Cat. Nos. listed have Class 10 overload relays. To order Class 20 overload relays, change the overload relay from S1_ to S2_. Example:
Cat. No. 105-A09AB3-S1A becomes Cat. No. 105-A09AB3-S2A.
Starter Cat. Nos. listed have Class 10 overload relays. To order Class 20 overload relays, change the overload relay from S4_ to S5_. Example:
Cat. No. 105-A09AB3-S4A becomes Cat. No. 105-A09AB3-S5A.

SMP-2 Overload Relay: Auto/Manual Reset, Selectable Trip Class 10, 15, 20 or 30, Phase Loss, Ground Fault,
and Jam Protection
Overload
Relay
Code

Full Load
For Use with Bulletin
Current
105, 106, 109, 112, 113, 120E, 132 and 133 Range (A)

A09
A30

A24

A18

A12

B1A
B1C
B1D
B1E
B1F

0.1.32
0.321.0
1.02.9
1.65.0
3.712
1232

For Use with Cat. No.


105, 106, 109, 112, 113, 120, 132 and 133
A45
A75
B110

B1H

All Sizes No overload relay

A60

XXX

B180
B250 and B300
B400
B600

A38

Full Load
Current
Range (A)

Overload
Relay
Code

1238
1445
2375
66110
57180
96300
128400
200630

B1H
B1J
B1K
B1L
B1M
B1N
B1P
B1R

SMP-3 Overload Relay


Contact Allen-Bradley Sales Office for availability and dimensions.
Note: Starters with SMP-1, SMP-2 or SMP-3 overload relays are not presently part of the AB Express Program.

3-34

Prices Consult Sales Office or price list

Bulletin 100 Line

Overload Relay Code Selection


Bimetallic Overload Relay: Auto/Manual Reset, Class 10
For Use With Bulletin
105, 106, 109, 112, 113, 120F, 132 and 133

A09
A12

A24

A18

A30

Full Load
Current
Range (A)

Overload
Relay
Code

0.10.16
0.16.24
0.24.40
0.40.60

A18
A26
A35
A70

0.601.0
0.801.2
1.01.6
1.52.3
2.03.0
2.84.2
4.06.0
5.58.0

A90
B12
B16
B22
B30
B42
B60
B80

6.010

C10

1016

C15

1624

C24

2232

C32

Full Load
Current
Range (A)

Overload
Relay
Code

1830

C30

3045

C45

4560

C63

6075

C75

B110

4466
66110

C66
D110

B180

80120
120200

D120
D200

B250 & B300

120180
180300

D180
D300

B400

160240
240400

D240
D400

252378

D378

378630

D630

For Use With Cat. No.


105, 106, 109, 112, 113, 120, 132 and 133
A45
A60
A75

A38

B600
All Sizes No Overload Relay

XXX

Bulletin 112 Starters with overload relay codes -C86, -D110, -D120, -D200 are not part of the AB-Express Program.

Prices Consult Sales Office or price list

3-35

Bulletin 198E

IEC Enclosures
Product Selection
3

IEC Enclosures

Style A

Style B

IP42 (Type 1) General Purpose Molded Plastic Enclosures


Enclosure Code
Style
A
A

Dim.
B01
B02

Bulletin Line
105

106

109
A09A12
A18A24

112

113

120

Cat. No.
198E-AA835
198E-AA845

IP66 (Type 4, 4X, 12) Raintight, Dusttight, Corrosion Resistant Molded Plastic Enclosures
198E-AK835
K01

A09A12

198E-AK845
K02

A18A24

A
A

IP42 (Type 1) General Purpose Metal Enclosures


Enclosure
Code

Bulletin Line

Style
B
B

Dim.
A02
A08

105

A09A24

106

A03

A09

A04

A10

A05

A30A45
A09A24

A60A75
A30A45

109
A09A24

A30A45
A09A24

112

113

A30A45

A60A75

A60A75

B110

120
Cat. No.
198E-BA966

A09A24 198E-BA996

A30A45
A09A24

A60A75
A30A45

198E-BA1176

198E-BA11116

198E-BA1278

198E-BA12138

198E-BA23108

Without control circuit transformer.


With control circuit transformer.

Accessories Page 3-38


Modifications Page 3-44
Approximate Dimensions Page 3-75

3-36

Mounting
Plate
Cat. No.

Prices Consult Sales Office or price list

198E-P2310

Bulletin 198E

IEC Enclosures
Product Selection, Continued
IEC Enclosures, Continued

Style D

IP66 (Type 3, 4, 12) Raintight, Dusttight, Metal Enclosures


Enclosure
Code

Bulletin Types

Mounting Plate
Cat. No.

Dim.

105

106

109

112

113

120

A04
A10

A09A24

A24

198E-DA1488T

198E-P148T

A09A45

A30A45

A30A45

198E-DA14168T

198E-P1416T

198E-DF10106

198E-P1010

198E-DF1286

198E-P128

198E-DF12126

198E-P1212

A09A45

F08

F03

F09

F04

A60A75

198E-DF1488

198E-P148

F04

A09A24

A24

198E-DF1488T

198E-P148T

F10

A60A75

198E-DF14168

198E-P1416

F10

A09A45

A30A45

A30A45

198E-DF14168T

198E-P1416T

A09A24

A60A75

A09A45
A09A24

A09A45

Cat. No.

Style

A60A75

A30A45

A30A45

A09A24

A30A45

Without control circuit transformer.


With control circuit transformer.

Accessories Page 3-38


Modifications Page 3-44
Approximate Dimensions Page 3-66

Prices Consult Sales Office or price list

3-37

Bulletin 100 Line

Accessories Field Installed


Accessories
3

Description

193-MB02
193-MB11
193-MB22

All A09A45
100L-_

2 N.O.
1 N.O.1 N.C.
2 N.C.
4 N.O.
3 N.O.1 N.C.
2 N.O.2 N.C.
4 N.C.

195-FA20
195-FA11
195-FA02
195-FA40
195-FA31
195-FA22
195-FA04

100-A09A45

2 N.O.
1 N.O.1 N.C.
2 N.C.
4 N.O.
3 N.O.1 N.C.
2 N.O.2 N.C.
4 N.C.

195-FA20G
195-FA11G
195-FA02G
195-FA40G
195-FA31G
195-FA22G
195-FA04G

All A09A30
100L-_

1 N.O.
1 N.C.
1 N.O.1 N.C.
2 N.O.
2 N.C.
1 N.C. (Late Break)
1 N.O.1 N.C. (Late Break)

195-BA10
195-BA01
195-BA11
195-BA20
195-BA02
195-BL01
195-BL11

All A38B300

1 N.O.
1 N.C.
1 N.O.1 N.C.
2 N.O.
2 N.C.
1 N.C. (Late Break)

195-GA10
195-GA01
195-GA11
195-GA20
195-GA02
195-GL01

All B400B600

1 N.O.
1 N.C.
1 N.O.1 N.C.
2 N.O.
2 N.C.

195-GA10
195-GB01
195-GB11
195-GA20
195-GB02

Gold Plated
Auxiliary Contact
Adder Deck
(Side Mounted,
8mA, 24V min.)

100-A09A30

1 N.O.
1 N.C.
1 N.O.1 N.C.
2 N.O.
2 N.C.

195-BA10G
195-BA01G
195-BA11G
195-BA20G
195-BA02G

Low Level
Switching
Auxiliary Contact
(8mA, 24V min.)

All A38B300

2 N.O.
2 N.C.

2-Pole

Auxiliary Contact
Adder Deck
(Side Mounted)

Solid-State Timing
Element

100-M_

196-MT3S

130 Second ON-Delay

196-MT30S

220V AC

196-MTSDA2

110V AC

196-MTSDA1

35mm DIN Rail Mounting Adapter for Above Timers


Pneumatic
Timer

All A09A45

0.1180 sec
On Delay
Off Delay

See page 3-56 for maximum number of auxiliary circuits.


Must be ordered in multiples of 10.
For maximum reliability, both contacts should be wired in parallel and used as a single circuit.

195-NX19
195-NX18

0.13 Second ON-Delay

Star-Delta Timer

3-38

Cat. No.

2 N.C.
1 N.O.1 N.C.
2 N.O.2 N.C

Gold Plated
Auxiliary Contact
Adder Deck
(Top Mounted, 8mA,
24V min.)
4-Pole

Type

100-M_
Auxiliary Contact
Adder Deck
(Top Mounted)

Cat. No. 195-MB22

Used with
Cat. No.

Prices Consult Sales Office or price list

196-MTM

196-FTA
196-FTB

Bulletin 100 Line

Accessories Field Installed


Accessories, Continued

Description

Used with
Cat. No.

Type

Electronic
Timing Relay

100-A09B300
100-L_

WYE-DELTA
ON/OFF Delay

Latch
Attachment

100-A09A45

Cat. No.

700-FS

Unlatch VA (Cont. Rated)


Inrush: 13.0 @ 50 Hz
197-FL
14.4 @ 60 Hz
Seal:
3.7 @ 5060 Hz

100-A09A30
DC
Interface
Module
Cat. No. 197-FL_

Cat. No. 199-FIMZ__

Interlock Kit

A DC input signal
can be used to
operate the
24240V AC
contactor coil

12V
24V
48V

199-FIMZ12
199-FlMZ24
199-FlMZ48

100-M_

Mechanical Interlock

199-MXM1

100-A09A30

Dual Interlock with


Mechanical and
Electrical Interlocks in
One Unit

199-MCA1

100-A38B300

199-MCD1
199-MXH1

100-B400
Mechanical Interlock Only

199-MXJ1

100-B600
R-C
Suppressor
MOV
Suppressor

100-M_

Diode
Suppressor
100-A09A30
100L-_

Surge
Suppressor

All A09A30

All A38B180
Cat. No. 199-FSMA1

Cat. No. 599-K04

All B250B600

2448V AC
110280V AC
1255V AC
56136V AC
137277V AC

199-MSMA48
199-MSMA1
199-MSMV1
199-MSMV2
199-MSMV3

12250V DC

199-MSMD1

12120V AC R/C
125240V AC R/C
2448V AC Varistor
50125V AC Varistor
130250V AC Varistor
6300V DC Diode
12120V AC Varistor
12240V AC Varistor
12120V AC Varistor

199-FSMA1
199-FSMA2
199-FSMA9
199-FSMA10
199-FSMA11
199-FSMZ-1
599-K04
599-KA04
199-GSMA1

Voltage Suffix Code

The Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No. 197-FL
becomes Cat. No. 197-FLA1.
Voltage

24V

110V

120V

220V

240V

380V

415V

50 Hz
60 Hz

B24
A24

A1

A1

A2

A2

B3

B41

The Cat. No. as listed is incomplete. For more information, see Bulletin 700, Type FS, in the Timers and Relays section.
Includes mounting plate and hardware for assembly of reversing contactors.
Must be ordered in multiples of 10.
Continued on next page.

Prices Consult Sales Office or price list

3-39

Bulletin 100 Line

Accessories Field Installed


Accessories, Continued

Description

Used with
Cat. No.

Type

Cat. No.

100-A09, A12

Twin Stab for Power


199-SC1
Terminals (50 per pack)

All Bulletin 100


Contactors

Single Stab for Coil


199-SC2
Terminals (20 per pack)

Stab Connector
Kits
Cat. No. 199-SC1

Cat. No. 199-SC2

199-LE1

100-B110

Terminal
Lug Kit

Terminal
Cover Kit

100-B180,
100W-B180_
100-B250, -B300,
100W-B300_

199-LF1
3 Lugs per kit

100-B400

199-LH1

100-B600,
100W-B600_

199-LJ1

100-B110

199-TCE1

100-B180

199-TCF1

100-B250, B300

Provides IP20 Finger


Protection
(1 Pair Per Kit)

199-TCG1

100-B400

193-TCH1

100-B600

193-TCJ1

DIN Rail
(1 Meter)

100-A09A45

Power
Wiring Kit

100-A09, A12
100-A18, A24
100-A30
100-A38, A45
100-A60, A75
100-B110
100-B180
100-B250, B300
100-B400
100-B600

35 x 7.5 mm

199-DR1

199-PWA1
199-PWB1
199-PWB2
Provides
199-PWC1
Interconnecting Power 199-PWD1
Wires for 3
199-PWE1
Squirrel Cage
199-PWF1
Reversing Motors
199-PWG1
199-PWH1
199-PWJ1

Not for use with Cat. No. 100-A38 and Cat. No. 100-A45 Pure DC Operated Contactors.
Must be ordered in multiples of 10.

3-40

199-LG1

Prices Consult Sales Office or price list

Bulletin 100 Line

Accessories Field Installed


Accessories, Continued

For Use With


Cat. No.

For Enclosure
Style

START-STOP
Push Button

109-A09
and A12

198-MS1

Flush green I/START


Extended red O/STOP

109-A18
and A24

198-MS2

All

B&D

109-A09
and A12

198-MS4

109-A18
and A24

198-MS5

105133
100L-_

B&D

198-MS6

FORWARD, REVERSE-STOP
Push Buttons

All

B&D

198-MS7

HIGH-LOW, STOP
Push Buttons

All

Description

Cat. No.

START-STOP
Push Button
198-MS3

Flush green I/START


Extended red O/STOP

ON-OFF
Push Button
Flush green ON
Extended red OFF

ON-OFF
Push Button

198-MS8
B&D

FAST-SLOW-STOP
Push Buttons
External RESET Button
(for Bimetallic and SMP Overload
Relays)
Flush gray R/RESET
External RESET Button
(for Bimetallic and SMP Overload
Relays)

198-MS9

All

109-A09
A24

198-MR1

All

B&D

198-MR3

105133
100L-_

B&D

198-MT1

All

B&D

198-MT2

105133
100L-_

B&D

198-MT3

Flush gray R/RESET


HAND-OFF-AUTO
Selector Switch
3 Position Maintained
Includes Legend Plate
FORWARD-OFF-REVERSE
Selector Switch
3 Position Maintained
OFF-ON
Selector Switch
2 Position Maintained

Requires mounting bracket Cat. No. 198-BR1 when using enclosure style B.

Continued on next page.

Prices Consult Sales Office or price list

3-41

Bulletin 100 Line

Accessories Field Installed


Accessories, Continued

For Use With


Cat. No.

Description
Red ON
Pilot Light

For
Enclosure Style

120V

Cat. No.

198-PL11R

198-PL12R

A09-A24
Resistor Type

240V

Red ON Pilot Light


Transformer Type

120V
208V
240V
480V
600V

105133
100L-_

B&D

120V
Dual ON Pilot Light
Forward Red
Reverse White

240V

198-PL21RW
105
106

480V
Pilot Device Mounting Bracket
(required when mounting pilot
devices in style B enclosures)

198-PL21R
198-PL25R
198-PL22R
198-PL23R
198-PL24R

198-PL22RW
198-PL23RW

105133
100L-_

All

B&D

1497-_ _ P

Control Circuit Fuse Block


For Class CC Rejection
Type Fuses
(Fuses Not Included)

105133
100L-_

B&D

1491-R162

Grounding Bushing Adapts to 1/2


N.P.T., PG 16.5 & BS20 mm threads

109
A09-A24

198-GR1

Terminal Shorting Bar Provides


jumper between ground and solid neutral
terminals.

109
A09-A24

198-GR2

Single Pole N.O.


Auxiliary Contact for
Disconnect Switch

106, 112

195-GA10

Control Circuit Transformer


With Top Mounted Fuse Block

198-BR1

Does not include Legend Plate. See page 11-299 for Bulletin 800E Legend Plate. Legend Plates for use on D enclosures only.
Requires mounting bracket Cat. No. 198-BR1 when using enclosure style B.
An auxiliary contact adaptor, Cat. No. 194R-AA, is required when installing auxiliary contact, Cat. No. 195-GA10.

3-42

Prices Consult Sales Office or price list

Bulletin 100 Line

Accessories Field Installed


Accessories, Continued

For Use With


Cat. No.
106,112-A09A24
106,112-A30A45
106,112-A60A75
106,112B110
106,112A180

Description

Fuse Cover for


Disconnect Switch

For
Enclosure
Style

All

194R-FCF1

106,112-B180B300

Closing Button
For 22.5mm
Round Panel Hole

Cat. No.
194R-FCA2
194R-FCJ60
194R-FCC1
194R-FCD1
194R-FCE1

B&D

198-N1

3 required per disconnect switch.

Bulletin 100-M Miniature Contactors Labelling Material

Connectors
Neutral Link
Labels
Marking Tags
Cover

Description
Double Spade
Single Spade
10mm
16mm
Adhesive Paper, 105/sheet
160 per sheet
Transparent/ Tag

Tag Carrier

Pkg. Qty.
50
50
1
1
10
10
100

For Clip-on Tags

100

Cat. No.
199-SC10
199-SC11
199-NL1
199-NL2
199-ID1
199-ID2
199-ID3

199-ID4

Clip-On Marking Tag Strip (10 per Strip)


Tag
Marking
110
1120
2130
3140
4150
5160
6170
7180
8190
91100
101110
111120
121130
131140
141150
151160
161170
171180
181190
191200

Pkg. Qty.
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25

Cat. No.
199-ID5
199-ID6
199-ID7
199-ID8
199-ID9
199-ID10
199-ID11
199-ID12
199-ID13
199-ID14
199-ID15
199-ID16
199-ID17
199-ID18
199-ID19
199-ID20
199-ID21
199-ID22
199-ID23
199-ID24

Tag
Marking Pkg. Qty.
1
25
2
25
3
25
4
25
5
25
6
25
7
25
8
25
9
25
9
25
Unmarked
25
09
25
+
25
25
A
25
B
25
C
25
D
25
E
25
F
25

Cat. No.
199-ID25
199-I26D
199-ID27
199-ID28
199-ID29
199-ID30
199-ID31
199-ID32
199-ID33
199-ID34
199-ID35
199-ID36
199-ID37
199-ID38
199-ID39
199-ID40
199-ID41
199-ID42
199-ID43
199-ID44

Prices Consult Sales Office or price list

Tag
Marking
G
H
I
J
K
L
M
N
0
P
Q
R
S
T
U
V
W
X
Y
Z

Pkg. Qty.
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25

Cat. No.
199-ID45
199-ID46
199-ID47
199-ID48
199-ID49
199-ID50
199-ID51
199-ID52
199-ID53
199-ID54
199-ID55
199-ID56
199-ID57
199-ID58
199-ID59
199-ID60
199-ID61
199-ID62
199-ID63
199-ID64

3-43

Bulletin 100 Line

Modifications Factory Installed


Modifications
3

Listed on this and the following pages are factory installed modifications and special features which are available for the low voltage
(600V maximum) starters listed in this catalog. To order, add a dash followed by the suffix number listed in these tables to the end
of the product Cat. No. Example: 109-A09AD3-B16-11.

Full Voltage Non-Reversing Starters (Bulletin 109)


Description of
Modification

Enclosure
Suffix
Code Style
Rating

START-STOP Push
Button

ON-OFF Push
Button

1E

HAND-OFF-AUTO
Selector Switch

OFF-ON Selector
Switch

3E

Red Pilot Light


(Transformer Type)

4R

A09

A12

A18

A24

A30

A38

A45

A60

A75

IP42 (1),
IP66 (4/4X)

B110 A180 B180 B250 B300 B400 B600

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1),
IP66 (4/4X)

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

Red LED Pilot Light


(120V)

4R1

IP42 (1),
IP66 (4/4X)

Red LED Pilot Light


(240V)

4R2

IP42 (1),
IP66 (4/4X)

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

Control Circuit
Transformer
2 Primary and
1 Secondary Fuse
Provided
(Standard Capacity)

IP42 (1)

NA

6P

IP66 (3/4/12)

NA

IP42 (1),
IP66 (4/4X)

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

1 External Reset

Enclosure Padlock
Attachment

11

Enclosure Mounting
Feet

12

Control Circuit
Fuse Block
2 Fuses Provided

22

1 N.O. 1 N.C.
Auxiliary Contact on
Contactor
(Side Mount)

901

1 N.O. 1 N.C.
Auxiliary Contact on
Contactor
(Top Mount)

901T

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

NA

NA

NA

NA

NA

NA

NA

NA

IP66 (3/4/12)

NA

NA

NA

NA

NA

NA

NA

NA

NA

A=Available Option
NA=Not Available
Not available for molded plastic enclosed devices.
When ordering in Canada, use suffix 6. Primary fusing is not required by the Canadian Electrical Code.

3-44

Prices Consult Sales Office or price list

Bulletin 100 Line

Modifications Factory Installed


Modifications, Continued
Full Voltage Reversing, Reversing Combination and Multi-Speed Starters (Bulletin 105, 106, 120E)
Description of
Modification

Enclosure
Suffix
Code Style
Rating

FOR-REV-STOP
Push Buttons

HIGH-LOW-STOP
Push Buttons

FOR-OFF-REV
Selector Switch

HIGH-OFF-LOW
Selector Switch

A12

A18

A24

A30

A38

A45

A60

A75

IP42 (1)

A09
A

B110 A180 B180 B250 B300 B400 B600


A

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

Red FOR
White REV
Pilot Lights

4RW

IP66 (3/4/12)

NA

Red HIGH
White LOW
Pilot Lights

4RW

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

Control Circuit
Transformer
2 Primary and
1 Secondary Fuse
Provided
(Standard Capacity)

6P

1 External Reset

2 External Resets
(Multi-Speed
Starters)

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

IP66 (3/4/12)

NA

IP42 (1)

NA

NA

NA

NA

NA

NA

NA

NA

NA

IP66 (3/4/12)

NA

NA

NA

NA

NA

NA

NA

NA

NA

Enclosure Padlock
Attachment

11

Enclosure Mounting
Feet

12

Control Circuit
Fuse Block
2 Fuses Provided

22

1 N.O. 1 N.C.
Auxiliary Contact on
Contactor
(Side Mount)

901

1 N.O. 1 N.C.
Auxiliary Contact on
Contactor
(Top Mount)

901T

A=Available Option
NA=Not Available
Bulletin 106 reversing combination starters are only available in style D enclosures.
Transformer Type.
When ordering in Canada, use suffix 6. Primary fusing is not required by the Canadian Electrical Code.

Prices Consult Sales Office or price list

3-45

Bulletin 100 Line

Modifications Factory Installed


Modifications, Continued
Full Voltage Non-Reversing Combination Starters (Bulletins 112, 113)
Description of
Modification

Enclosure
Suffix
Code Style
Rating

START-STOP
Push Button
HAND-OFF-AUTO
Selector Switch
Red Pilot Light
Control Circuit
Transformer
2 Primary and
1 Secondary
Fuse Provided
(Standard Capacity)
External Reset
Fuse Cover (For
Disconnect Switch)
Enclosure Padlock
Attachment
Enclosure Mounting
Feet
Control Circuit Fuse
Block
2 Fuses Provided
N.O. Auxiliary
Contact (On
Disconnect Switch)

1
3
4R

A09

A12

A18

A24

A30

A38

A45

A60

A75

$ A

NA

NA

NA

NA

IP66 (3/4/12)

NA

NA

NA

NA

IP42 (1)

NA

NA

NA

NA

IP66 (3/4/12)

NA

NA

NA

NA

IP42 (1)

NA

NA

NA

NA

IP66 (3/4/12)

NA

NA

NA

NA

IP42 (1)

NA

NA

NA

NA

IP66 (3/4/12)

NA

NA

NA

NA

IP42 (1)

NA

NA

NA

NA

IP66 (3/4/12)

NA

NA

NA

NA

IP42 (1)

NA

NA

NA

NA

IP66 (3/4/12)

NA

NA

NA

NA

IP42 (1)

NA

NA

NA

NA

IP66 (3/4/12)

NA

NA

NA

NA

IP42 (1)

NA

NA

NA

NA

IP66 (3/4/12)

NA

NA

NA

NA

IP42 (1)

NA

NA

NA

NA

IP66 (3/4/12)

NA

NA

NA

NA

IP42 (1)

NA

NA

NA

NA

IP66 (3/4/12)

NA

NA

NA

NA

IP42 (1)

NA

NA

NA

NA

IP66 (3/4/12)

NA

NA

NA

NA

IP42 (1)

NA

NA

NA

NA

IP66 (3/4/12)

NA

NA

NA

NA

IP42 (1)

B110 A180 B180 B250 B300 B400 B600

6P

7
8
11
12

22

98

1 N.O. 1 N.C.
Auxiliary Contact on
Contactor
(Side Mount)

901

1 N.O. 1 N.C.
Auxiliary Contact on
Contactor
(Top Mount)

901T

A=Available Option
NA=Not Available
Transformer Type.
When ordering in Canada, use suffix 6. Primary fusing is not required by the Canadian Electrical Code.

3-46

Prices Consult Sales Office or price list

Bulletin 100 Line

Modifications Factory Installed


Modifications, Continued
Pump Control Panels (Bulletin 132 and 133)
Description of
Modification

Enclosure
Suffix
Code Style
Rating

A09

A12

A18

A24

A30

A38

A45

A60

A75

4R

IP32 (3R)

NA

NA

NA

NA

NA

Control Circuit
Transformer
2 Primary and
1 Secondary
Fuse Provided
(Standard Capacity)

6P

IP32 (3R)

NA

NA

NA

NA

NA

Control Circuit
Transformer
2 Primary and
1 Secondary
Fuse Provided
(100VA Extra
Capacity)

6XP

IP32 (3R)

NA

NA

NA

NA

NA

Control Circuit
Fuse Block
2 Fuses Provided

22

IP32 (3R)

NA

NA

NA

NA

NA

Motor Saver
(Model 400)
Voltage Monitor

190

IP32 (3R)

NA

NA

NA

NA

NA

Motor Saver
(Model 520)
Current Monitor

191

IP32 (3R)

NA

NA

NA

NA

NA

Lightning Arrestor

192

IP32 (3R)

NA

NA

NA

NA

NA

Surge
Suppressor

193

IP32 (3R)

NA

NA

NA

NA

NA

24 Hour
Timer Clock
(Includes
50VA 120 CPT)

194

IP32 (3R)

NA

NA

NA

NA

NA

Back Spin Timer

195

IP32 (3R)

NA

NA

NA

NA

NA

Red Pilot Light

B110 A180 B180 B250 B300 B400 B600

A=Available Option
NA=Not Available
Transformer Type.
When ordering in Canada, use suffix 6. Primary fusing is not required by the Canadian Electrical Code.

Prices Consult Sales Office or price list

3-47

Bulletin 100 Line

IEC Specifications
Specifications
3

Bulletin 100-M Miniature Contactor


Electrical
Operating Range
Drop Out

Coil Consumption

Contactors
Control Relays
Alternating current AC
Direct current DC
AC
Inrush VA
Sealed VA
DC
Inrush VA
Sealed VA

85110% of rated voltage


80110% or rated voltage
3565% nominal coil voltage
1025% nominal coil voltage
22 VA
1.4 VA
2.5 Watts
2.5 Watts

Mechanical
Operating Time

Pick-Up
Drop Out

40 ms
20 ms

In store, transport
In operation AC-1, enclosed
AC-2AC-4
at rated operational current
at 85% rated operational current
In operation AC-1, open
Humid heat
Alternating climatic conditions
Direct current operation DC)

55C+ 80C (67F176F)

Environmental

Ambient Temperature

Resistance to Climatic Change

Mounting Position

50C+60C (58F140F)
50C+70C (58F158F)
50C+40C (58F104F)
40C (104F), 95% relative humidity, 56 days
23C (73.4F), 83% / 40C, 93%, 56 cycles

No restrictions (maximum pull-in voltage and


temperature range with all permissible auxiliary
contact adder decks
any position
Alternating current operation AC

Construction
Protection against Accidental Contact

Protection against finger and back of the hand


contact

Terminals

Wire
Stranded lead
Without Connector Sleeve
With Connector Sleeve

Product Selection Page 3-4


Accessories Page 3-38
Approximate Dimensions Page 3-65

3-48

According to VBG 4
2 x 0.75 mm22.5 mm2 (1814 AWG)
2 x 1.02.5 mm2 (1814 AWG)
2 x 0.751.5 mm2 (1816 AWG)

Bulletin 100 Line

IEC Specifications
Specifications, Continued
Bulletin 100-M Miniature Contactors Electrical Life
Duty classification and actuation for electrical service life verification (number of actuations under load in accordance with
IEC 158-1).
Test Conditions
Making
U/Ue
cos.

I/Ie

Duty Classification
Non-inductive or slightly inductive loads, resistance furnaces
Slip ring motors: starting and reversing

AC-3

Squirrel cage motors: starting, switching off running motors

Ie

AC-4

Squirrel cage motors: starting, reversing, jogging

Ie

AC-11
Ue
U
Ur

Electromagnets for contactors, valves, lifting means

Breaking
Ur/Ue cos.

1
2.5

1
1

0.95
0.65

1
2.5

1
1

0.95
0.65

17A

0.65

0.17

0.65

17A

0.65

0.65

10
Ie
I
Ic

0.7

0.4

Rated operational voltage


Voltage before make
Recovery voltage

Electrical service life of contactors as a function of breaking current.


The graph is valid up to 380/415V, 50/60 Hz, for switching of most types of motors and
under most operating conditions including duty classifications AC-2 though AC-4 as well
as for ohmic and slightly inductive loads (AC-1).
The electrical service life established under the above test conditions for the various duty
classifications is shown in the adjacent graph as a function of breaking current. In
general, these values can be used without hesitation for contact selection purposes.

Rated operation current


Making current
Breaking current
100-M05
100-M09

Electrical service life (millions make/break)

AC-1
AC-2

Ic/Ie

Breaking current (A)

Permissible frequency of operations for Bulletin 100-M mini-contactors


Switching of running squirrel-cage motors (AC-3)
Switching of motors during start-up (AC-2 and AC-4)
Relative duty cycle 40%
Starting time tA = 0.25%

Duty cycle tED = 0.25 s (<tA)

Motor rated current le [A]

1.25

2.5

Operation /h

8000

2500

1200

600

Starting current lA [A]

1.25

20

36

Operations /h

8000

1200

300

120

Product Selection Page 3-4


Accessories Page 3-38
Approximate Dimensions Page 3-65

3-49

Bulletin 100 Line

IEC Specifications
Specifications, Continued
Bulletin 100-M Accessories
Electrical
Operational Voltage

Voltage Drop
Load current for reliable function
Load current at
20C (68F)
40C (104F)
55C (131F)
Leakage current at 220V
Time range (delayed operation)
Transition time Y/
Reset time
Voltage failure duration having no influence on time
sequence
Repeat accuracy
At fixed temperature
With temperature range of
5C+55C (23F+131F)
Time interval for start commands

General
Functional description

Cat. No. 196-M

Cat. No. 196-MSD

AC and DC
110V 23%250V +10%

AC only, 50/60 Hz
110V 23%120V +10%
220V 20%240V +10%
5V maximum
10 mA minimum

5V maximum
10 mA minimum
600 mA
440 mA
320 mA
5 mA
0.13 seconds
130 seconds

200 ms

600 mA
440 mA
320 mA
Y 17 mA, 6 mA
130 seconds

15 ms

200 ms

1%

1%

5%
1.4 X set time

5%
2 X set time

Cat. No. 196-M

Cat. No. 196-MSD

90 ms 30 ms
200 ms

After the set time has expired, contactor


After the set time has expired, the timer
KY is switched off, and after the fixed
completes the circuit and switches on the
switching interval 90 30 ms, contactor
series connected contactor.
K is switched on.

Circuit diagrams

Time setting

The 0.1 through 3 seconds and 1 through 30 seconds delay period is preset by
means of the seconds marking and then corrected according to the process
sequence or by checking with a stop watch.

Environmental

Cat. No. 196-M

Cat. No. 196-MSD

20C+55C (40F+131F)
40C+80C (40F+176F)

20C55C (40F+131F)
40C+80C (40F+176F)

Cat. No. 196-M

Cat. No. 196-MSD

Ambient temperature
in operation
in store

Construction
Terminals:
0.8mm2 (AWG 18)

2 free cable ends, each 250mm long

4 free cable ends, each 250mm long

Surge Suppressors
Electrical
Overvoltage factor

Product Selection Page 3-4


Accessories Page 3-38
Approximate Dimensions Page 3-65

3-50

Cat. No. 196-M

Cat. No. 196-MSD


n = Umax/Un = 0.8 to 2.5

Bulletin 100 Line

IEC Specifications
Specifications, Continued
Bulletin 100-M Miniature Contactors
Electrical Ratings
Description
Operating Voltage
/th
AC-1

Open
Enclosed

Cat. No. 100-M05

Cat. No. 100-M09

220

240

380

415

500

220

240

380

415

500

A
kW
A
kW

20
7.5
16
6

20
8.3
16
6.7

20
13.1
16
10.5

20
14.3
16
11.5

20
17.3
16
14

20
7.5
16
6

20
8.3
16
6.7

20
13.1
16
10.5

20
14.3
16
11.5

20
17.3
16
14

6.5

5.3

4.8

12

11

8.2

kW
HP
A
kW
HP
A
kW
HP

1.5
2
6.5
1.5
2
9
2.2
3

1.5
2
6
1.5
2
8
2.2
3

2.2
3
5.3
2.2
3
8.5
3.7
5

2.2
3
4.8
2.2
3
7.6
3.7
5

2.2
3
4
2.2
3
6.5
3.7
5

3
4
12
3
4
15
4
5.5

3
4
11
3
4
14
4
5.5

4
5.5
9
4
5.5
16
7.5
10

4
5.5
8.2
4
5.5
14
7.5
10

4
5.5
7
4
5.5
12
7.5
10

0.6

1.25

Switching of 3-Phase Motors


AC-2

Slip ring motors

AC-3

Squirrel cage motor


Normal loading
Squirrel cage motor
Heavy-duty-operation
Inching

AC-4

Star-Delta Starting
Rated insulation voltage
according to IEC 158-1
Test Voltage 1 minute
Back-Up Fuse
without thermal overload relay

500

500

3000

3000

20

20

Auxiliary Contacts
Auxiliary
Contact
Block

AC-11
/th open
/th enclosed

Contactor

AC-11
/th open
/th enclosed

Back-Up Fuse
Number of Auxiliary Contacts

A
A
A

0.6

10
6
6

2.5

2
10
6

1.25

2.5

A
A

16
12

16
12

10
15

10
15

/th in accordance with IEC, AS, BS, SEV. Corresponds to the continuous current rating /th2 according to VDE.
Rated power according to IEC, AS, BS, DEMKO, NEMKO, SEMKO, Finland, SEV, VDE for 3 phase non-inductive loads (50 through 60 Hz).
Open values refer to 40C (104F) ambient temperature. Enclosed values refer to 60C (140F) ambient temperature.
Rated current power for 50 through 60 Hz in accordance with IEC, AS, BS, SEV, VDE. Same data as AC-3 for occasional inching/plugging (AC-4).

Product Selection Page 3-4


Accessories Page 3-38
Approximate Dimensions Page 3-65

3-51

Bulletin 100 Line

IEC Specifications
Specifications
Bulletin 100 Magnetic Contactors
Electrical Life in Utilization Categories AC1 and AC2
Life-Load Curves
Bulletin 100 IEC-based contactors are designed for superior performance in a wide variety of applications. When selecting IEC-based
products, the user must give consideration to the specific load, utilization category and required electrical life of the application. The
life-load curves listed here are based on Allen-Bradley tests according to the requirements defined in IEC 947-4158-1. Since contact
life in application conditions is dependent on environmental conditions and duty cycle, actual application contact life may vary from
that indicated by the curves shown here.
To find the contactors estimated electrical life, follow these guidelines:
1. Choose the appropriate graph that most closely approximates the utilization category of the application.
2. Locate the intersection of the life-load curve of the appropriate contactor with the applications operational current (le) found on
the horizontal axis.
3. Read the estimated contact life in millions of operations along the vertical axis.
Utilization Categories
Category
AC1
AC2
AC3
AC4

Typical Duty
Non-inductive or slightly inductive loads.
Starting of slip-ring motors.
Starting of squirrel cage motors and switching off only after the motor is up to speed.
Starting of squirrel cage motors with inching and plugging duty.
A12

A24

A09

A18

A38
A30

A60
A45

B110

A75

B180

A09

A12

B250

A24

A18

B300
B400

A38

A30

A60
A45

B250

A75

B110

B180

B300

B600

B400

B600

10M
8M

10M
8M

AC2

6M

AC1

6M
4M

MILLIONS OF MAKE/BREAK OPERATIONS

MILLIONS OF MAKE/BREAK OPERATIONS

4M

2M

1M
800K
600K
400K

200K

100K
80K
60K

2M

1M
800K
600K
400K

200K

100K
80K
60K
40K

40K
20K
20K
10K
10K
1

10

20

40

60

80 100

AC1 le (Amperes)

Product Selection Page 3-4


Accessories Page 3-38
Approximate Dimensions Page 3-65

3-52

200

400

600 800 1000

8 10

20

40

60

80 100

AC2 le (Amperes)

200

400

600 800 1000

Bulletin 100 Line

IEC Specifications
Specifications, Continued
Bulletin 100 Magnetic Contactors
Contact Life for Mixed Utilization Categories AC3 and AC4
In many applications, the utilization category cannot be defined as either purely AC3 or AC4. In those applications, the electrical
life of the contactor can be estimated from the following equation:

L
AC3
= -------------------------------------------------------mixed
LAC3

1+P
--------------- 1

AC4 L

AC4

Lmixed
LAC3
LAC4
PAC4

Where

Approximate contact life for a mixed AC3/AC4 utilization category application.


Approximate contact life in operations for AC3 utilization category (from AC3 life-load curves below).
Approximate contact life in operations for AC4 utilization category (from AC4 life-load curves below).
Percentage of AC4 operations.
A09

A18
A12

A38
A24

A30

A60
A45

B110

B180

B250

A75

A24

B300
B400

B600

A18

6M

4M

4M

2M

2M

1M

400K

200K

B180

B250
B300
B600

AC4

1M
800K
600K
400K

200K

100K

100K

80K

80K

60K

60K

40K

40K

20K

20K

10K

B110

A75

10M
8M

AC3

600K

A60

A45

B400

6M

800K

A38
A30

A09

MILLIONS OF OPERATIONS

MILLIONS OF OPERATIONS

10M
8M

A12

10K
1

8 10

20

40

60

80 100

200

400

600 800 1000

AC3 Ie (Amperes)

8 10

20

40

60 80 100

200

400

600 800 1000

AC4 Ie (Amperes)

Electronic Selection Disk with Automatic Life-Load Calculations.


See Section 19, Software and Support for details. Cat. No. 100-SG1.

Product Selection Page 3-4


Accessories Page 3-38
Approximate Dimensions Page 3-65

3-53

Bulletin 100 Line

IEC Specifications
Specifications, Continued
Bulletin 100 Magnetic Contactors
Electrical Ratings
Contactor Size
Rated thermal current Ith @ +40C (+104F)

Rated insulation voltage IEC (Ui)/UL

Ratings: AC1 @ +40C (+104F)

100-A09

100-A12

100-A18

100-A24

100-A30

100-A38

22

22

35

35

45

80

80

660/600

ie

22

22

35

35

45

Ie

12

18

24

30

38

7.5
15
18.5
18.5
11
22
30
30

10
18.5
22
18.5
15
30
37
37

220V
Ratings: AC2, AC3, AC4
380/415V
50 Hz @ +55C
500V
660V
220V
Star-Delta/Wye-Delta
380/415V
Ratings:
AC3, 50 Hz, Non-Reversing
500V
Contactors Carry Phase Current 660V
Ie

kW
kW
kW
kW
kW
kW
kW
kW
A

2.2
4
5.5
5.5
4
7.5
11
11

3
5.5
7.5
7.5
5.5
11
15
15

4
7.5
11
11
7.5
15
18.5
18.5

5.5
11
15
15
11
18.5
22
25

12

18

24

30

38

200V
Ratings: AC2, AC3, AC4
230V
60 Hz @ +55C
460V
575V
200V
Star-Delta/Wye-Delta
230V
Ratings:
AC3, 60 Hz, Non-Reversing
460V
Contactors Carry Phase Current 575V
Maximum fuse size Type 2 co-ordination
Average impedance per pole m

HP
HP
HP
HP
HP
HP
HP
HP
A
m

2
2
5
7-1/2
5
5
10
15
25
2.4

3
3
7-1/2
10
5
7-1/2
15
20
25
2.4

5
5
10
15
7-1/2
10
20
25
40
2.1

5
7-1/2
15
20
7-1/2
10
25
30
40
2.1

7-1/2
10
20
25
10
15
30
40
63
2.1

10
10
25
30
15
20
40
50
80
1.5

VA
VA
VA
VA

Watts

71
6.7
77
6.2
0.25
0.27
1.7

71
6.7
77
6.2
0.25
0.27
1.7

77
77
6.9
6.9
84
84
6.5
6.5
0.26
0.26
0.28
0.28
1.7
1.7
85110% of rated voltage

83
7.9
90
7.7
0.24
0.25
1.9

153
20
161
19
0.22
0.23
4.4

Watts
Inrush Watts
Sealed Watts

8.7

8.7

8.7
8.7

80110% of rated voltage

8.7

10
160
1.58

AC Coil Data
Coil consumption 10%

Power factor 10%

50 Hz Inrush
50 Hz Sealed
60 Hz Inrush
60 Hz Sealed
50 Hz Sealed
60 Hz Sealed

Heat dissipation
Coil operating limits

DC Coil Data
Pure DC Coil
DC Coil consumption 10%

Economized
DC Coil

Coil operating limits

Auxiliary Contacts
Rated thermal current Ith

10A

Rated insulation voltage IEC (Ui)/UL

660/600V

Terminal size
Ratings AC15

Ratings DC13

Product Selection Page 3-17


Accessories Page 3-38
Approximate Dimensions Page 3-66

3-54

12120V
220240V
380480V
500660V
28
110
220
440
660

24mm2/#12 AWG
6A
3A
1.5A
1.2A
5.0A
1.25A
0.62A
0.27A
0.20A

Bulletin 100 Line

IEC Specifications
Specifications, Continued
Bulletin 100 Magnetic Contactors
Electrical Ratings, Continued
100-A45

100-A60

100-A75

100-B110

80

100

100

160

80
45
11
22
30
22
22
37
45
45
45
10
15
30
40
20
25
50
60
100
1.5

100
60
15
30
37
37
30
55
75
75
60
15
20
40
50
30
40
75
100
125
1.2

100
75
22
37
45
45
37
63
80
80
75
20
25
50
60
40
50
100
125
125
1.2

160
110
30
55
75
75
45
90
110
110
110
30
40
75
100
60
60
150
150
200
0.5

327
37
348
34
0.19
0.20
6.8

327
37
348
34
0.19
0.20
6.8

537
72
552
64
0.21
0.21
12.5

17
309
2.69

17
309
2.69

24
383
3.32

100-B180

100-B250

100-B300

100-B400

100-B600

400

400

600

800

400
255
75
132
160
160
110
220
280
280
250
75
100
200
250
125
150
350
400
400
0.3

400
304
90
160
200
200
140
257
315
315
304
100
100
250
300
150
200
400
450
500
0.3

600
414
120
220
280
280
220
350
450
445
414
125
150
350
400
225
250
500
600
630
0.3

800
608
180
315
445
445
277
545

608
200
250
500
600
350
400

1000
0.1

825
1562
85
124
840
1596
75
113
0.22
0.25
0.25
0.28
19.0
35.4
85110% of rated voltage

1562
124
1596
113
0.25
0.28
35.4

3300
290
3312
253
0.22
0.24
61.2

4884
281
4860
254
0.22
0.26
65.7

225
660/600
225
180
45
90
110
110
80
150
180
180
180
60
60
150
150
75
100
225
250
315
0.4

AC Coil Data
153
20
161
19
0.22
0.23
4.0

DC Coil Data
10
160
1.58

518
3.57

80110% of rated voltage

Auxiliary Contacts
10A
660/600V
24mm2/#12 AWG
6A
3A
1.5A
1.2A
5.0A
1.25A
0.62A
0.27A
0.20A
Product Selection Page 3-17
Accessories Page 3-38
Approximate Dimensions Page 3-66

3-55

Bulletin 100 Line

IEC Specifications
Specifications, Continued
Bulletin 100 Magnetic Contactors Rating
Mechanical

Contactor Size

100-A09

100-A12

100-A18

100-A24

100-A30

100-A38

IP 20

lP 20

lP 20

IP 20

lP 20

IP 20

20

20

15

15

15

15

AC Coil

DC Coil

1320
44
612
9
44

1320
44
612
9
44

1725
47
612
9
30.1

1725
47
612
9
30.1

1624
45
613
14
40

1222

611

AC3

600

600

600

600

600

600

AC4

300

300

300

300

Degree of protection
(Open Type) IEC 529
Mechanical life, operations in millions
Max. number of auxiliary
circuits (includes aux.
contact supplied as
standard with contactor)

Operating times at normal Pick-up


voltage at +20C in
milliseconds
Drop-out
DC with suppression
Maximum operating
rates all contactors
(operations/hr)

AC
DC
AC
DC

Refer to Allen-Bradley

Construction
Contact material:
Main contacts
Auxiliary contacts
Terminal markings
Terminal sizes

Silver Alloy

M3.5
(#6-32)

Cable size maximum (1 or 2 wires)

Silver
CENELEC EN50 012 and NEMA
M3.5
M4.0
M4.0
M5.0
(#6-32)
(#8-32)
(#8-32)
(#10-32)

2-4mm2
2-4mm2
2-6mm2
2-6mm2
2-10mm2
(2-#12 AWG) (2-#12 AWG) (2-#10 AWG) (2-#10 AWG) (2-#8 AWG)

Recommended tightening torque


(Power cables)

1.4 N-m
(12 in-lbs)

1.4 N-m
(12 in-lbs)

1.4 N-m
(12 in-lbs)

1.4 N-m
(12 in-lbs)

2.8 N-m
(25 in-lbs)

Environmental (Common Data)


Temperature

Operation
Storage

Altitude
Resistance to corrosion
Operating position

(open)
(enclosed)

25C+55C (13F+131F)
25C+40C (13F+104F)
40C+65C (40F+149F)
2000m per IEC 947-4
Steel parts zinc plated and chromated

22.5

90

For applications with 9-30A DC operated contactors, consult Allen-Bradley Sales Office.

Product Selection Page 3-17


Accessories Page 3-38
Approximate Dimensions Page 3-66

3-56

90

22.5

M6.0
(1/4-20)
1-25mm2
(1-#4 AWG)
5.1 N-m
(45 in-lbs)

Bulletin 100 Line

IEC Specifications
Specifications, Continued
Mechanical, Continued
100-A45

100-A60

100-A75

100-B110

100-B180

100-B250

100-B300

100-B400

100-B600

IP 20

lP 20

lP 20

IP 00

lP 00

IP 00

IP 00

IP00

IP00

15

15

15

10

10

1222

611

1429

514

1429

514

1635

514

2024

920

1842

717

1842

717

1636

618

2579

1022

600

400

400

400

300

150

150

150

150

M12.0
(1/213)

M12.0
(1/213)

M12.0
(1/213)

1-240mm2
(1-500
MCM AWG)
42 N-m
(375 in-lbs)

2-185mm2
(2-350
MCM AWG)
31 N-m
(275 in-lbs)

2-240mm2
(2-500
MCM AWG)
31 N-m
(275 in-lbs)

Refer to Allen-Bradley

Construction
Silver Alloy
Silver
CENELEC EN50 012 and NEMA
M8.0
M10.0
M12.0
(5/1618)
(3/816)
(1/213)

M6.0
(1/420)

M8.0
(5/1618)

M8.0
(5/1618)

1-25mm2
(1-#4 AWG)

1-35mm2
(1-#2 AWG)

1-35mm2
(1-#2 AWG)

1-50mm2
(1-#1/0 AWG)

1-120mm2
(1-#4/0 AWG)

5.1 N-m
(45 in-lbs)

5.6 N-m
(50 in-lbs)

5.6 N-m
(50 in-lbs)

16.9 N-m
(150 in-lbs)

31 N-m
(275 in-lbs)

1-240mm2
(1-500
MCM AWG)
42 N-m
(375 in-lbs)

Environmental (Common Data)


25C+55C (13F+131F)
25C+40C (13F+104F)
40C+65C (40F+149F)
2000m per IEC 947-4
Steel parts zinc plated and chromated

22.5
90

22.5

22.5 22.5

22.5 22.5

90

Recommended torque when using proper Bulletin 199 terminal lug kit (see page 3-40).

Product Selection Page 3-17


Accessories Page 3-38
Approximate Dimensions Page 3-66

3-57

Bulletin 100 Line

IEC Specifications
Specifications, Continued
Bulletin 100W Welding Contactors

Description

Cat. No.
Suffix - B180

Coil Operating Limits


Coil Consumption 10%
50 Hz Inrush (VA)
60 Hz Inrush (VA)
50 Hz Sealed (VA)
60 Hz Sealed (VA)

Cat. No.
Suffix - B300

Cat. No.
Suffix - B600

85110% of Rated Voltage

825
840
85
75

1562
1596
124
113

4730
4680
216
216

Operating Times at normal


voltage at +20C
in Milliseconds
Pickup
Dropout
Ambient Temperature Range
Operation:
Storage:
Terminal Capacity (Maximum)
Coil (1 or 2 Wires)

2044 msec
920 msec

1842 msec
717 msec
Open: 25C+55C (13F+131 F)
Enclosed: 25C+40C (13F+104 F)
40C+65C (40F+149F)

2579 msec
1022 msec

4mm2/#12AWG

4mm2/#12AWG

4mm2/#12AWG

Power Terminals

1-#1/0 AWG

1-240mm2
1-500 MCM AWG

2-240mm2
2-500 MCM AWG

Product Selection Page 3-8


Accessories Page 3-40
Approximate Dimensions Page 3-72

3-58

Bulletin 100 Line

IEC Specifications
Application Data
Guidelines for Short Circuit Protective Device Selection
Determine the level of protection required for the application;
i.e., is Type 2 Coordination, ASTA Certification or UL Listing
of the application required? Select the protective device
required for the application from the column labeled for the
level of protection required. For U.S. applications, in no case
should the protective device selected exceed the maximum
device rating as allowed per Article 430 of the National Electric
Code.
UL Listed Combinations
UL Listed for the combination of contactor, or contactor and
overload relay, and the maximum size short circuit protection
device. UL List combinations are listed for a maximum short
circuit current of 5kA.
UL Certified Type 2 Combinations
Certified to provide Type 2 coordination under short circuit
conditions (as defined by IEC Standard 947-4-1) with the

combination of contactor, overload relay and maximum size


short circuit protective device. UL Certified Type 2
combinations are certified for a maximum short circuit current
of 100kA. For additional information about UL Type 2
Certification, refer to Allen-Bradley Publication 100-2.8.
ASTA Certified Type 2 Combinations
Certified by ASTA (Association of Short Circuit Testing
Authorities) to provide Type 2 coordination under short circuit
conditions when using the listed combination of contactor,
overload relay and GEC manufactured type BS88 fuses. This
certification is applicable in countries where British Standards
or derivatives of such are applied to electrical installation.
ASTA Certified combinations are certified for a maximum short
circuit current of 80kA.

Contactors Only
Maximum Short Circuit Protection Device Rating/Setting in Amperes
Type 2 Coordination

UL Listed Combinations

Contactor Cat.
No. Suffix

UL Class K1/RK1,
J, CC Fuses

BS88 Fuses

gL Fuses

UL Class K5/RK5/
L Fuses

Circuit Breakers

-A09
-A12
-A18
-A24
-A30
-A38
-A45
-A60
-A75
-B110
-B180
-B250
-B300
-B400
-B600

15
25
25
40
50
110
110
200
225
300
400
450
601 (Class L)
800 (Class L)
1200 (Class L)

25
25
32
32
40
80
100
125
125
200
315
400
500
630
1000

25
25
35
35
40
80
100
125
125
200
315
400
500
630
1000

40
60
90
90
90
110
110
200
225
300
400
450
601 (Class L)
800 (Class L)
1200 (Class L)

15
15
50
50
90
110
110
175
200
300
400
450
450
800

In Canada, CSA Certified when using CSA fuse designation HRCI-J.


In Canada, CSA Certified when using CSA fuse designation HRCII-C, HRCI-R.
In Canada, CSA Certified when using CSA fuse designation HRC-L.

Note: Class CC fuses have a 60A maximum rating.

3-59

Bulletin 100 Line

IEC Specifications
Application Data, Continued
Contactors and Overload Relays Used Together (Starters)
Maximum Short Circuit Protection Device Rating/Setting in Amperes
UL Listed
Combinations

UL Certified Type 2
Combination

Contactor Cat.
No. Suffix

Overload
Relay

UL Class K5/RK5
Fuses

Circuit
Breakers

UL Class J
Fuses
(CSA HRCI-J
Fuse )

-A09
-A09
-A09
-A09
-A09
-A09
-A09
-A09
-A09
-A09
-A09
-A09
-A09
-A12
-A12
-A12
-A18
-A18
-A18
-A18
-A18
-A18
-A18
-A18
-A18
-A18
-A18
-A18
-A18
-A18
-A18

BSA18
BSA26
BSA35
BSA70
BSA90
BSB12
BSB16
BSB22
BSB30
BSB42
BSB60
BSB80
BSC10
BSB80
BSC10
BSC15
BSA18
BSA26
BSA35
BSA70
BSA90
BSB12
BSB16
BSB22
BSB30
BSB42
BSB60
BSB80
BSC10
BSC15
BSC24

1
1
1
1
3
3
6
6
10
15
20
30
40
30
40
60
1
1
1
1
3
3
6
6
10
15
20
30
40
60
90

15
15
15
15
15
15
15
15
15
15
20
25
30
45
50

2
3
6
6
10
10
15
10
15
20

2
3
6
6
10
10
15
20
30

ASTA
Certified
Type 2
Combinations

UL Listed
Time-Delay Class
CC (CSA HRCIMISC.) Fuse

Using GEC BS88


Fuses

2.5
3
6
6
10
20
20
20
20
30

2.5
3
6
6
10
20
20
30

NIT6
NIT6
NIT10
NIT16
NIT20
NIT20M25
NIT20M25

NIT20M32

TIA32M35
TIA32M40

CSA fuse designation HRCI-J must also be UL Listed as Class J fuses.


In Canada, CSA Certified when using CSA fuse designation HRCI-J, HRCI-T.
Only Littelfuse manufactures a UL Listed Class CC time delay specifically for use in motor circuits. Class CC fuses are available through 30A
only. CSA HRCI-MISC fuses must also be UL Listed as Class CC fuses.
ASTA Certification requires the use of these GEC fuses.

Note: Class CC fuses have a 60A maximum rating.

3-60

Bulletin 100 Line

IEC Specifications
Application Data, Continued
Contactors and Overload Relays Used Together (Starters)
Maximum Short Circuit Protection Device Rating/Setting in Amperes
UL Listed
Combinations

UL Certified Type 2
Combination

Contactor Cat.
No. Suffix

Overload
Relay

UL Class K5/RK5
Fuses

Circuit
Breakers

UL Class J
Fuses
(CSA HRCI-J)
Fuse

-A24
-A24
-A30
-A30
-A38
-A38
-A45
-A45
-A60
-A75
-A75
-B110
-B110
-B180
-B180
-B180
-B250
-B250
-B300
-B300
-B400
-B400
-B600
-B600

BSC15
BSC24
BSC24
BSC32
CPC30
CPC45
CPC30
CPC45
CPC63
CPC63
CPC75
HPC66
HPD110
DPC88
DPD120
DPD200
EPD180
EPD300
EPD180
EPD300
FPD240
FPD400
GPD378
GPD630

60
90
90
90
110
110
110
110
200
200
225
250
300
350
400
400
450
450
450
450
700 (Class L)
800 (Class L)
1000 (Class L)
1200 (Class L)

45
50
50
90
110
110
110
110
175
175
200
250
300
350
350
400
450
450
450
450
700
800

20
30
30
40

50

50
80
80
100

150

200

300

300

ASTA
Certified
Type 2
Combinations

UL Listed
Time-Delay Class
CC (CSA HRCIMISC.) Fuse

Using GEC BS88


Fuses

30

TIA32M50

TIA32M63

TIS63M80

TIS63M80
TIS63M100

TCP100M125

TF160

TF200
TF200M250
TF200M250
TK315M355

TK315M355

TTM500

In Canada, CSA Certified when using CSA fuse designation HRCII-C, HRCI-R.
CSA fuse designation HRCI-J must be UL Listed as Class J fuses.
Class CC fuses are available through 60A only. CSA HRCI-MISC fuses must also be UL Listed as Class CC fuses.
ASTA Certification requires the use of these GEC fuses.
10kA maximum short circuit current available.
Class K5 fuse.
18kA maximum short circuit available Class L fuse.
In Canada, CSA Certified when using CSA fuse designation HRC-L.

3-61

Bulletin 100 Line

IEC Specifications
Application Data, Continued
Switching Three Phase Capacitors
Operating Conditions
Maximum Rated voltage 660 Volts AC.
Maximum Ambient Temperature +40C.
Operating Rate
Single capacitor banks with damping. No more than 10 operating per hour. For applications requiring more than 10 operations per
hour contact your local Allen-Bradley Sales Office for information.
Power Rating in KVAR
60Hz

50Hz

Cat. No. Suffix

200V

240V

480V

600V

220V

380V

500V

660V

-A09
-A12
-A18
-A24
-A30
-A38
-A45
-A60
-A75
-B110
-B180
-B400
-B600

3
4
6
8
10.5
13
16
20
25
30
40
105
160

3.5
4.5
7.5
10
12.5
18
20
25
30
38
50
125
190

7
9
15
19
25
35
40
45
55
75
100
250
380

8
10
16
20
25
35
40
45
55
75
100
200
300

3
4.5
6.5
9
11.5
15
18
20
25
35
45
115
170

5.5
7
11.5
15
20
25
30
35
45
60
80
200
300

8
10
16
20
25
35
40
45
55
75
100
250
400

8
10
16
20
25
35
40
45
55
75
100
200
300

Maximum available current of 10kA. For systems with larger available current, contact Allen-Bradley Sales Office.

Lighting Loads
Typical Electric Discharge Loads
Mercury vapor, sodium vapor, metal halogen and fluorescent lamps.
Compensated Loads
Loads that use a power factor correction capacitor to improve the power factor of the load. These loads typically exhibit an inrush
current of 15 to 20 times the continuous current of the load.
Selection Information
To select a contactor for controlling a lighting load, use the following procedure:
1. Determine the type of load to be controlled. For example is it a incandescent type load or an electric discharge type;
compensated or non-compensated type?
2. Determine the continuous current of the lighting load.
3. Select a contactor that has a current rating greater than or equal to the continuous rating of the load that is being switched.
Maximum Switching Current
Electric Discharge Lamp Loads <= 300V

Cat. No.
Suffix

Circuit Closing Inrush


Current (Amps Peak
Including Offset)

Non-Compensated
(Amps)

Compensated
Amps

Incandescent Lamp Loads


(Amps)

-A09
-A12
-A18
-A24
-A30
-A38
-A45
-A60
-A75
-B110
-B180
-B250
-B300
-B400
-B600

136
182
273
364
455
576
682
909
1136
1667
2727
3788
4546
6061
9091

12
16
23
31
39
52
62
72
90
140
225
317
380
520
720

9
12
18
24
30
38
45
60
75
110
180
250
300
400
600

9
12
18
24
30
38
45
60
75
110
180
250
300
400
600

When using contactor Cat. Nos. 100-A09 through 100-A24, all four poles can be used for switching lighting loads.

3-62

Bulletin 100 Line

IEC Specifications
Application Data, Continued
Controller Ratings for Transformer Primary - Switching kVA
Operating Conditions
Maximum Rated voltage 660 Volts
Maximum Ambient Temperature +40C.
Operating Rate
Less than 120 operations per hour, but no more than 2 per minute.
Inrush Currents of not more than 20 Times Peak Continuous Current Ratings
kVA for Single Phase Volts

kVA for Three Phase Volts

Cat. No.
Suffix

120V

240V

480V

600V

208V

240V

380V

480V

600V

660V

-A09
-A12
-A18
-A24
-A30
-A38
-A45
-A60
-A75
-B110
-B180
-B250
-B300
-B400
-B600

.72
.96
1.4
1.9
2.4
3.1
3.6
4.8
6.0
9
12
16
19
26
39

1.5
1.9
2.9
3.9
4.8
6.1
7.2
9.6
12
16
23
32
39
51
77

2.9
3.9
5.8
7.7
9.6
12
14
19
24
32
46
64
77
92
139

3.6
4.8
7.2
9.6
12
15
18
24
30
36
52
72
87
92
139

2.2
2.9
4.3
5.8
7.2
9.2
11
14
18
24
35
48
58
77
116

2.5
3.3
5
6.7
8.4
11
13
17
21
28
40
56
67
89
134

4
5.3
7.9
11
13
17
20
26
33
44
63
88
106
140
210

5
6.7
10
13
17
21
25
33
42
56
80
111
134
160
240

6.2
8.3
12
16
20
26
31
41
52
62
90
125
150
160
240

6.8
9.1
13
18
23
29
34
45
57
69
99
138
165
160
240

3-63

Bulletin 100 Line

IEC Specifications
Application Data, Continued
Switching DC Loads
Use the following tables as a guideline for selecting the proper Bulletin 100 contactor for switching DC loads. Notice that these
guidelines are only for three power poles wired in series. Note: L/R in the tables below is equal to the ratio of inductance to resistance
in the circuit being switched and is measured in milliseconds. The higher this ratio or time constant the more stored energy the
circuit contains.
DC1 Ratings L/R 1 millisecond
(3 poles in series)

DC3 & DC5 Ratings L/R 15 millisecond


(3 poles in series)

Maximum Operational
Current at +40C Amperes

Maximum Operational
Current at +40C Amperes

Cat. No.

115 Volts

230 Volts

Cat. No.

115 Volts

230 Volts

100-A09
100-A12
100-A18
100-A24
100-A30
100-A38
100-A45
100-A60
100-A75
100-B110
100-B180
100-B250
100-B300
100-B400
100-B600

22
22
35
35
45
65
65
100
100
150
200
300
300
400
630

10
10
22
22
25
60
60
100
100
150
200
300
300
400
630

100-A09
100-A12
100-A18
100-A24
100-A30
100-A38
100-A45
100-A60
100-A75
100-B110
100-B180
100-B250
100-B300
100-B400
100-B600

9
12
18
24
30
38
45
60
75
110
180
250
300
400
600

3
4
5
6
8

110
180
250
300
200
300

Minimum application current must be 25% of maximum operational current.


Maximum operational currents for 4 poles in series:
Catalog Nos. 100-A09 and 100-A12 = 8A; and, Cat. Nos. 100-A18 and 100-A24 = 15A.
Not suitable for application at 230 volts.

Example of 3 Poles Wired in Series

L1

L2

L3

T1

T2

T3

Load

DC Utilization Categories
Category

Typical Applications

DC1
DC3
DC5

Non-inductive or slightly inductive loads; resistive furnaces.


Shunt motors; starting, plugging or inching; Dynamic breaking of DC motors.
Series motors; starting, plugging or inching; Dynamic breaking of DC motors.

3-64

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions

Bulletin 100-M Miniature Contactors


Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
77
(3-5/64)

45
(1-13/16)
4
(1/16)

50
(1-31/32)
56
(2-15/64)

74
(2-59/64)
48
(1-29/32)
4
(1/16)

5
(3/16)

78
(3-7/64)
48
(1-29/32)
4
(1/16)

47
(1-7/8)

Mini-Contactor or Mini-Relay With Auxiliary


Contact Adder Deck or Timer Mounted to Front.
Cat. No. 100-M or 700-M

Mini-Contactor or Mini-Relay With


Surge Suppressor Mounted to Front.
Cat. No. 100-M or 700-M

67
(2-43/64)
45
(1-13/16)
4
(1/16)

10
(25/64)

31.5
(1-1/4)

19.5
(25/32)

120
(4-51/64)

5
(3/16)
32
(1-9/32)

30
(1-13/64)

Surge Suppressor
Cat. No. 199-MSM

Mini-Contactor or Mini-Relay With Auxiliary Contact Adder


Deck Mounted to Front and Timer Mounted to Side.
Cat. No. 100-M or 700-M

90
(3-39/64)
4
(1/16)

50
(1-31/32)
56
(2-15/64)

45
(1-13/16)

5
(3/16)

77
(3-5/64
)
74
(2-59/64)
48
(1-29/32)
4
(1/16)

47
(1-7/8)

Reversing Mini-Contactors With Auxiliary Contact Adder Deck.


Cat. No. 104-M

11
(7/16)
11
(7/16)

45
(1-13/16)

22
(7/8)
41
(1-41/64)
Timer With DIN Rail Mounting Adapter on 35mm DIN Rail.
Cat. No. 196-MT

23.5
(15/16)

Timer With DIN Rail Mounting Adapter on 35mm DIN Rail.


Cat. No. 196-MT

Product Selection Page 3-6


Accessories Page 3-38
Specifications Page 3-48

3-65

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions
Bulletin 100 AC Operated Contactors
Dimensions are shown in millimeters (inches) and shipping weights in kg (lbs).
Dimensions are not intended for manufacturing purposes.
F

A
J

E
C

Contactor
Size

A
Wide

B
High

C
Deep

100-A09 and
45
74
84
60
35
6
5
50
11
86
100-A12
(1-13/16) (2-59/64) (3-5/16) (2-23/64) (1-3/8) (15/64) (3/16) (1-31/32) (7/16)
(3-3/8)
100-A18 and
55
83
92
75
35
4
10
60
11.5
94
100-A24
(2-11/64) (3-17/64) (3-5/8) (2-11/64) (1-3/8)
(5/32) (25/64) (2-23/64) (29/64) (3-11/16)
55
102
108
90
40
5
7.5
75
12.5
111
100-A30
(2-11/64) (4-1/64)
(4-1/4) (3-35/64) (1-37/64) (3/16) (19/64) (2-61/64) (1/2)
(4-3/8)

A
L

Approx.
Ship Wt.
kg (lbs.)

Mounting
Screw
M4
(#8-32)
M4
(#8-32)
M4
(#8-32)

AC

DC

0.431 0.678
(.95) (1.50)
0.522 0.817
(1.15) (1.80)
0.708 1.108
(1.56) (2.44)

Coil
Removal
Clearance

E
C
K

Contactor
Size

A
WIde

B
HIgh

C
Deep

100-A38 and
100-A45
100-A60 and
100-A75

75
(2-61/64)
93
(3-21/32)

112.4
(4-27/64)
130
(5-1/8)

125
(4-59/64)
143
(5-5/8)

100
(3-15/16)
110
(4-21/64)

55
(2-5/32)
80
(3-5/32)

5.5
(7/32)
10
(25/64)

7.5
(19/64)
5.5
(7/32)

128.7
(5-1/16)

Product Selection Page 3-6


Accessories Page 3-38
Specifications Page 3-48

3-66

Mounting
Screw

Approx
Ship Wt.
kg (lbs.)

63.5
(2-1/2)
59
(2-5/16)

M4
(#8-32)
M5
(#10-32)

1.25
(2.76)
2.09
(4.61)

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions, Continued
Bulletin 100 AC Operated Contactors
Dimensions in millimeters (inches) and shipping weights in kg (lbs).
Dimensions are not intended for manufacturing purposes.
C

A
E

Coil
Removal

K Clearance

D
H

Lug Kit

Contactor
Size
100-B110
100-B180
100-B250 and
100-B300

A
Wide

B
High

C
Deep

119
(4-11/16)
134
(5-9/32)
154
(6-5/64)

154
(6-1/16)
187.8
(7-25/64)
226
(8-29/32)

155
(6-7/64)
190
(7-31/64)
212
(8-11/32)

130
(5-1/8)
160
(6-5/16)
180
(7-3/32)

100
(3-15/16)
110
(4-21/64)
130
(5-1/8)

12
(15/32)
13.9
(35/64)
18
(45/64)

9
(11/32)
13
(33/64)
15
(19/32)

187.3
(7-3/8)
227
(8-15/16)
292
(11-1/2)

Mounting
Screw

Approx.
Ship Wt.
kg (lbs.)

62
(2-29/64)
90
(3-35/64)
109
(4-19/64)

M6
(1/4-20)
M6
(1/4-20)
M8
(5/16-18)

3.85
(8.49)
7.00
(15.43)
8.24
(18.17)

Mounting
Screw

Approx.
Ship Wt.
kg (lbs.)

M10
(3/8-16)
M12
(1/2-13)

13.88
(30.60)
23.32
(51.41)

A1
F
K

H
D

Lug Kit
A

Contactor
Size

A
Wide

A1
Wide

B
High

C
Deep

176
189
255
230
199
154
28
11
344
10.5
(6-15/16) (7-29/64) (10-3/64) (9-3/64) (7-27/32) (6-1/16) (1-7/64)
(7/16) (13-35/64) (13/32)
255
306
267
220
226
33
145
433
10
100-B600

(10)
(12-3/64) (10-17/32) (8-1/16) (8-29/32) (1-19/64) (5-45/64) (17-3/64) (25/64)
100-B400

Product Selection Page 3-6


Accessories Page 3-38
Specifications Page 3-48

3-67

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions, Continued
Bulletin 100 DC Operated (Pure DC Coil) Contactors
Dimensions are shown in millimeters (inches) and shipping weights in kg (lbs).
Dimensions are not intended for manufacturing purposes.
Contactor or Relay with Timer or Auxiliary Contact Adder Deck
A

D
BULLETIN
100

C
BULLETIN
100

196-FT A
196-FTB

195-FA

A
Wide

Cat. No.
B

B
High

165
(6-1/2)

136
(5-23/64)

2
(5/64)

50
60
(1-31/32) (2-23/64)

35
(1-3/8)

100-A18 &
55
83
113
173
144
100-A24 (2-11/64) (3-17/64) (4-29/64) (6-13/16) (5-43/64)

2
(5/64)

60
75
(2-23/64) (2-61/64)

35
(1-3/8)

3
(1/8)

75
90
40
(2-61/64) (3-35/64) (1-37/64)

100-A09 &
45
74
105
100-A12 (1-13/16) (2-59/64) (4-5/32)

100-A30

55
102
(2-11/64) (4-1/64)

129
(5-3/32)

189
160
(7-7/16) (6-19/64)

100-A38 &
75
122
134
192
163
100-A45 (2-61/64) (4-13/64) (5-17/64) (7-9/16) (6-27/64)

J
E

100
55
(3-15/16) (2-11/64)

Contactor
A

BULLETIN
100

Cat. No.

A Wide

B High

C Deep

100-A60 &
100-A75

95
(3-3/4)
119
(4-11/16)

130
(5-1/8)
154
(6-1/16)

159
(6-17/64)
197
(7-3/4)

110
(4-1/32)
130
(5-1/8)

80
(3-5/32)
100
(3-15/16)

100-B110

Contactor with Bulletin 193 Bimetallic Overload Relays


A
C
H

F
G
E
B

K
J
D

Cat. No.
100-A09 &
100-A12
100-A18 &
100-A24
100-A30
100-A38 &
100-A45
100-A60 &
100-A75

A
Wide

B
High

C
Deep

45
(1-25/32)
56
(2-13/64)
54
(2-5/32)
75
(2-61/64)
95
(3-3/4)

119
(4-11/16)
127
(5)
145
(5-45/64)
175
(6-29/32)
187
(7-3/8)

105
(4-5/32)
113
(4-29/64)
129
(5-3/32)
133
(5-1/4)
159
(6-1/4)

119
(4-11/16)
124
(4-7/8)
119
(4-11/16)
103
(3-31/32)
124
(4-23/32)

81
(3-11/64)
91
(3-37/64)
109
(4-19/64)
129
(5-1/16)
137
(5-25/64)

60
(2-23/64)
75
(2-61/64)
90
(3-35/64)
100
(3-15/16)
110
(4-15/32)

50
(1-31/32)
60
(2-23/64)
75
(2-61/64)

35
(1-3/8)
35
(1-3/8)
40
(1-37/64)
55
(2-1/64)
80
(3-5/32)

6
(15/64)
17
(43/64)
14
(9/16)
21
(7/16)
31
(1-9/64)

2
(5/64)
2
(5/64)
2
(5/64)

Product Selection Page 3-6


Accessories Page 3-38
Specifications Page 3-48

3-68

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions, Continued
Bulletin DC Operated (Economized DC Coil) Contactor
Dimensions are shown in millimeters (inches) and shipping weights in kg (lbs).
Dimensions are not intended for manufacturing purposes.
Contactor with Timer or Auxiliary Contact Adder Deck

DC
Economizing
Module
196-FT
195-F
B

A
Wide

Cat. No.

Coil
Removal
G
Clearance

B
High

100-A38 &
75
144.4
125
185
156
100-A45 (2-61/64) (5-11/16) (4-59/64) (7-19/64) (6-5/32)

3.7
(5/32)

92.5
100
55
(3-41/16) (3-15/16) (2-1/64)

C
D

Contactor
DC Economizing
Module
F

Coil Removal
Clearance

BULLETIN
100

Cat. No.
100-A60 &
100-A75

100-B110
100-B180

A
Wide

B
High

C
Deep

93
(3-21/32)
119
(4-11/16)
134
(5-9/32)

160
(6-19/64)
177.4
(6-63/64)
212
(8-11/32)

147
(5-51/64)
155
(6-7/64)
190
(7-31/64)

110
(4-1/32)
130
(5-1/8)
160
(6-5/16)

80
(3-5/32)
100
(3-15/16)
110
(4-21/64)

88
(3-15/32)
89
(3-1/2)
119
(4-11/16)

Contactor with Bulletin 193 Bimetallic Overload Relays


DC
Economizing
Module
A
G

DC
Economizing
Module

Coil Removal
Clearance

F
G
E
B

J
D
C

Cat. No.

A
Wide

B
High

C
Deep

100-A38 &
100-A45
100-A60 &
100-A75

75
(2-61/64)
95
(3-3/4)

207
(8-5/32)
217
(8-35/64)

125
(4-59/64)
147
(5-51/64)

94
(3-11/16)
108
(4-1/4)

129
(5-1/16)
137
(5-25/64)

100
(3-15/16)
110
(4-15/32)

92.5
(3-41/64)
88
(3-15/32)

55
(2-1/64)
80
(3-5/32)

11
(7/16)
29
(1-9/64)

3.7
(5/32)

Product Selection Page 3-6


Accessories Page 3-38
Specifications Page 3-48

3-69

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions, Continued
Bulletin 104 Reversing Contactors (AC Operated)
Dimensions are shown in millimeters (inches) and shipping weights in kg (lbs).
Dimensions are not intended for manufacturing purposes.
A

K
G

Mounting
Screw

Approx.
Ship Wt.
kg (lbs)

86
(3-11/32)

M4
(#8-32)

0.925
(2.04)

60
(2-23/64)

84
(3-45/64)

M4
(#8-32)

1.084
(2.39)

75
(2-61/64)

111
(4-3/8)

M4
(#8-32)

1.474
(3.25)

Contactor
Size

A
Wide

B
High

C
Deep

104-A09 and
104-A12

102
(4-1/64)

74
(2-59/64)

84
(3-5/16)

60
(2-23/64)

92
(3-5/8)

6
(15/64)

5
(3/16)

50
(1-31/32)

104-A18 and
104-A24

122
(4-13/16)

83
(3-17/64)

92
(3-5/8)

75
(2-61/64)

102
(4-1/64)

4
(5/32)

10
(25/64)

104-A30

122
(4-13/16)

102
(4-1/64)

108.5
(4-17/64)

90
(3-35/64)

107
(4-7/32)

5
(3/16)

7.5
(19/64)

152.5
(6-1/64)
135
(5-5/16)

7.5
(5/16)

63.5
(2-1/2)

4 Mtg. Screws, M4 (#832)

112.4
(4-27/64)

100
(3-13/16)
160
(6-5/16)

5.5
(7/32)
1Auxiliary
Contact
(195-GA)

125
(4-59/64)

2.5
(3/32)

128.7
(5-1/16)

Contactor Size 104-A38 and 104-A45

189
(7-7/16)
150
(5-29/32)

18.5
(47/64)

Approximate Shipping Weight: 2.5kg (5.5 lbs)

4 Mtg. Screws, M5 (#1032)


7
(9/32)

59 (2-21/64)

190
(7-31/64)

Coil
Removal
Clearance

130
(5-1/8)

175
(6-7/8)

155.4
(6-1/8)
8
(5/16)

Contactor Size 104-A60 and 104-A75

Product Selection Page 3-6


Accessories Page 3-38
Specifications Page 3-48

3-70

Approximate Shipping Weight: 4.8kg (10.5 lbs)

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions, Continued
Bulletin 104 Reversing Contactors (AC Operated), Continued
Dimensions are shown in millimeters (inches) and shipping weights in kg (lbs).
Dimensions are not intended for manufacturing purposes.
A

H
D

Coil
Removal
Clearance

Contactor
Size
104-B110
104-B180
104-B250 and
104-B300

Lug Kit

A
Wide

B
High

C
Deep

239
225
164
205
216
(9-27/64) (8-33/64) (6-29/64) (8-1/16)
(8-1/2)
269
255
200
235
245
(10-19/32) (10-3/64) (7-7/8)
(9-1/4) (9-21/32)
311
270
221
250
280
(12-15/64) (10-5/8) (8-45/64) (9-27/32) (11-1/64)

10
(25/64)
10
(25/64)
10
(25/64)

11.9
(15/32)
12
(15/32)
15.5
(39/64)

65
187.4
(2-9/16)
(7-1/2)
100
227
(3-15/16) (9-5/64)
108
292
(4-19/64) (11-31/64)

Mounting
Screw

Approx.
Ship Wt.
kg (lbs)

M6
(1/4-20)
M6
(1/4-20)
M8
(5/16-18)

8.2
(18.1)
15.1
(32.2)
21.1
(46.5)

G
E

Contactor
Size
104-B400
104-B600

A
Wide

B
High

C
Deep

426
(16-49/64)
595
(23-13/32)

275
(10-13/16)
346
(13-5/8)

250
(9-27/32)
290
(11-7/16)

230
(9-3/64)
263
(10-11/32)

400
(15-3/4)
558
(21-31/32)

26
(1-1/64)
41.6
(1-41/64)

13
(33/64)
18.2
(23/32)

Mounting
Screw

Approx.
Ship Wt.
kg (lbs)

344
(13-35/64)
433
(17-3/64)

M10
(3/8-16)
M12
(1/2-13)

33.6
(74.0)
59.4
(131.0)

Product Selection Page 3-6


Accessories Page 3-38
Specifications Page 3-48

3-71

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions, Continued
Bulletin 100W Welding Contactors
Dimensions in millimeters (inches) and shipping weights in kg (lbs).
Dimensions are not intended for manufacturing purposes.
C

A
E

Coil
Removal

K Clearance

D
H

Lug Kit

Contactor
Size

A
Wide

B
High

C
Deep

100W-B180N2
134
188b
194
160
110
13.9
100W-B180N3 (5-9/32) (7-13/32) (7-41/64) (6-5/16) (4-21/64) (35/64)
100W-B300N2
154
226
212
180
130
18
100W-B300N3 (6-5/64) (8-29/32) (8-11/32) (7-3/32) (5-1/8)
(23/32)

Approx.
Mounting Mounting Ship Wt.
Screw
Hole
kg (lbs.)

13
227
90
M6
(33/64) (8-15/16) (3-35/64) (1/4-20)
15
292
109
M8
(19/32) (11-1/12) (4-19/64) (5/16-18)

7
(9/32)
8.7
(11/32)

7.00
(15.4)
8.24
(18.2)

A1
F
K

H
D

Lug Kit
A

Contactor
Size

A
Wide

100W-B600N2
255
100W-B600N3 (10-3/64)

B
High
305
(12)

Product Selection Page 3-8


Accessories Page 3-40
Specifications Page 3-58

3-72

C
Deep

284
220
226
33
14.5
433
(11-3/16) (8-11/16) (8-29/32) (1-19/64) (37/64) (17-3/64)

K
10
(25/64)

Approx..
Mounting Mounting Ship Wt.
Screw
Hole
kg (lbs.)
M12
(1/2-13)

14
(35/64)

23.3
(51.4)

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions
Bulletin 100L Lighting Contactors Open Type
Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes
12 Pole
8 Pole
4 Pole
55
(2-5/32)

4
(5/32)

55.7
(2-3/16)

35
(1-3/8)

83
(3-9/32)
Mtg.

75
(2-15/16)
Mtg.

55.7
(2-3/16)

195-FA
197-FL

60
(2-3/8)
Mtg.

92
(3-5/8)
4.4 (3/16) Dia.
Mtg. Holes
10
(3/8)

55.7
(2-3/16)

123
(4-7/8)
55.7
(2-3/16)

153
(6-1/16)

110.7
(4-3/8)
166.3
(6-9/16)

Bulletin 100L Lighting Contactors Enclosed IP42 (Type 1)


Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
A
Wide

Cat. No.
100L-A20A4
100L-A20A8
100L-A20A12

B
High

C
Deep

23.4
(15/16)

140
220
152
175
(5-1/2) (8-21/32) (5-31/32) (6-7/8)
235
220
152
175
(9-1/4) (8-21/32) (5-31/32) (6-7/8)
270
290
152
245
(10-5/8) (11-7/16) (5-31/32) (9-21/32)

95
(3-3/4)
190
(7-1/2)
225
(8-7/8)

22.5
(7/8)
22.5
(7/8)
22.5
(7/8)

7.1 (1/4) DIA.


for 1/4,or M6 Screw
3 Mtg. Holes

Product Selection Page 3-11


Accessories Page 3-38
Specifications Page 3-11

3-73

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions
Bulletin 100L Lighting Contactors Enclosed IP65 (Type 12) and IP66 (Type 3/4/12)
A
G

Cat. No.

100L-A20F8
100L-A20F12

6
(15/64)

100L-A20F4

7.1
(1/4)

4 5.5 (7/32)
DIA. Mtg. Holes

A
Wide

B
High

200
300
(7-7/8)
(11-13/16)
250
250
(9-27/32) (9-27/32)
300
300
(11-13/16) (11-13/16)

Product Selection Page 3-11


Accessories Page 3-38
Specifications Page 3-11

3-74

4 5.5 (7/32) X
7.1 (1/4) Mtg. Holes

C
Deep

160
(6-5/16)
160
(6-5/16)
160
(6-5/16)

236
(9-9/32)
186
(7-5/16)
236
(9-9/32)

76
(3)
76
(3)
178
(7)

62
(2-7/8)
87
(3-7/16)
61
(2-13/32)

17.5
(11/16)
17.5
(11/16)
17.5
(11/16)

313
(12-5/16)
263
(10-3/8)
313
(12-5/16)

105
(4-1/8)
105
(4-1/8)
206
(8-1/8)

47.5
(1-7/8)
72.5
(2-7/8)
47
(1-27/32)

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions
IEC Enclosures
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
B

.272
.212
X
(9/32) (7/32)

Pilot Light K.O.


16.5
(.650 dia.)

Push Button K.O.

22.3
(.898 dia.)
G

G
External Reset K.O.
22.13

(.898 dia.)
Back View
.212
.272
X
(7/32) (9/32)

Enclosure Code
Style
A
A

Dim.
B01
K01
B02
K02

A Height
195
(7-11/16)
205
(8-5/64)

B Width
86.6
(3-13/32)
96.6
(3-47/64)
23.4
(.921)

C Depth
123
(4-53/64)
131
(5-5/32)

D
175
(6-57/64)
185
(7-9/32)

E
10
(25/64)
10
(25/64)

F
22
(55/64)
27
(1-3/64)

G
175
(6-57/64)
185
(7-9/32)

7.1 (.28) DIA.


FOR 1/4 OR M6 SCREW
3 MTG. HOLES

Enclosure Code
Style

Dim.

A02

A08

A03

A09

A04

A10

A05

A Height
220
(8-21/32)
220
(8-21/32)
290
(11-27/64)
290
(11-7/16)
315
(12-27/64)
315
(12-27/64)
585
(23-1/32)

B Width
140
(5-33/64)
235
(9-1/4)
188
(7-23/64)
270
(10-5/8)
188
(7-23/64)
325
(12-51/64)
257
(10-7/64)

C Depth
152
(5-31/32)
152
(5-31/32)
152
(5-31/32)
152
(5-31/32)
203
(8)
203
(7-63/64)
203
(8)

D
175
(6-57/64)
175
(6-57/64)
245
(9-41/64)
245
(9-21/32)
270
(10-5/8)
270
(10-5/8)
540
(21-17/64)

E
95
(3-3/4)
190
(7-31/64)
140
(5-33/64)
225
(8-55/64)
140
(5-33/64)
280
(11-1/64)
210
(8-17/64)

F
22.5
(57/64)
22.5
(57/64)
24
(15/16)
22.5
(57/64)
24
(15/16)
22.5
(57/64)
23.5
(59/64)

Product Selection Page 3-36

3-75

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions, Continued
IEC Enclosures
Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
B

Style D
Metal Enclosures
Hinged Door Design
IP42 (Type 1)
IP66 (Type 4/4X/12)

Enclosure Code
Type

Style

Dim.
A04
A06
A10

IP42
(Type 1)

A11
A12
A13
A14
F08
F03
F09
F04
F06

IP66
(Type 3/4/12)

D
F10
F11
F12
F13
F14

A Height
350
(13-25/32)
762
(30)
350
(13-25/32)
610
(24)
762
(30)
1,219
(48)
1,295
(51)
250
(9-13/16)
300
(11-13/16)
300
(11-13/16)
350
(13-25/32)
762
(30)
350
(13-25/32)
610
(24)
762
(30)
1,219
(48)
1,295
(51)

Style F
Metal Enclosures
Hinged Door Design
With Drip Hood
IP32 (Type 32)

B Width
200
(7-7/8)
305
(12)
400
(15-3/4)
406
(16)
610
(24)
610
(24)
914
(36)
250
(9-13/16)
200
(7-7/8)
300
(11-13/16)
200
(7-7/8)
305
(12)
400
(15-3/4)
406
(16)
610
(24)
610
(24)
914
(36)

B
E

C Depth
210
(8-9/32)
276
(10-7/8)
210
(8-9/32)
230
(9-1/16)
281
(11-1/16)
302
(11-7/8)
353
(13-7/8)
160
(6-5/16)
160
(6-5/16)
160
(6-5/16)
210
(8-9/32)
276
(10-7/8)
210
(8-9/32)
230
(9-1/16)
281
(11-1/16)
302
(11-7/8)
353
(13-7/8)

4 5.5 (.22) Dia.


7.1 (.28)
Mtg. Holes

D Mtg.
315
(12-13/32)
724
(28-1/2)
315
(12-13/32)
572
(22-1/2)
724
(28-1/2)
1,181
(46-1/2)
1,257
(49-1/2)
186
(7-5/16)
265
(10-7/16)
236
(9-5/16)
315
(12-13/32)
724
(28-1/2)
315
(12-13/32)
572
(22-1/2)
724
(28-1/2)
1,181
(46-1/2)
1,257
(49-1/2)

E Mtg.
76
(3)
267
(10-1/2)
178
(7)
368
(14-1/2)
572
(22-1/2)
572
(22-1/2)
876
(34-1/2)
76
(3)
76
(3)
178
(7)
76
(3)
267
(10-1/2)
178
(7)
368
(14-1/2)
572
(22-1/2)
572
(22-1/2)
876
(34-1/2)

F
64
(2-1/2)
19
(3/4)
111
(4-3/8)
19
(3/4)
19
(3/4)
19
(3/4)
19
(3/4)
87
(3-13/32)
62
(2-7/16)
61
(2-13/32)
64
(2-1/2)
19
(3/4)
111
(4-3/8)
19
(3/4)
19
(3/4)
19
(3/4)
19
(3/4)

G (Dia.)
5.5
(7/32)
11
(7/16)
5.5
(7/32)
11
(7/16)
11
(7/16)
11
(7/16)
11
(7/16)
5.5
(7/32)
5.5
(7/32)
5.5
(7/32)
5.5
(7/32)
11
(7/16)
5.5
(7/32)
11
(7/16)
11
(7/16)
11
(7/16)
11
(7/16)

7.1
(.28)

D
A

6
(15/64)

4 5.5 (.218) Dia.


Mtg. Holes

Enclosure Code
Style

Dim.
F01
F02

F
F03
F04

3-76

A Height
584
(23)
864
(34)
1067
(42)
1219
(48)

B Width
320
(12-19/32)
447
(17-19/32)
762
(30)
914
(36)

C Depth
187
(7-5/16)
238
(9-5/16)
305
(12)
305
(12)

D
711
(28)
991
(39)
1118
(44)
1270
(50)

E
105
(4-1/8)
105
(4-1/8)
686
(27)
686
(27)

F
108
(4-1/4)
171
(6-3/4)
38
(1-1/2)
114
(4-1/2)

G
679
(26-3/4)
959
(37-3/4)
1092
(43)
1245
(49)

H
667
(26-1/4)
946
(37-1/4)
1092
(43)
1245
(49)

J
105
(4-1/8)
105
(4-1/8)

K
105
(4-5/32)
169
(6-21/32)

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions
Bulletin 105 and 109 Open Style Starters
B

Starter Type

109

105

Starter
Current
Rating

Voltage

924A

AC

912A

DC

1824A

DC

30A

AC

30A

DC

3845A

AC

3845A

DC

60A

AC

60A

DC

75A

AC

75A

DC

110A

AC

110A

DC

924A

AC

912A

DC

1824A

DC

30A

AC

30A

DC

3845A

AC

3845A

DC

60A

AC

60A

DC

75A

AC

75A

DC

110A

AC

110A

DC

A Height

B Width

C Depth

202.4
(7-63/64)
202.4
(7-63/64)
202.4
(7-63/64)
247.6
(9-3/4)
247.6
(9-3/4)
247.6
(9-3/4)
247.6
(9-3/4)
323.9
(12-3/4)
323.9
(12-3/4)
323.9
(12-3/4)
323.9
(12-3/4)
323.9
(12-3/4)
323.9
(12-3/4)
202.4
(7-63/64)
202.4
(7-63/64)
202.4
(7-63/64)
247.6
(9-3/4)
247.6
(9-3/4)
247.6
(9-3/4)
247.6
(9-3/4)
323.9
(12-3/4)
323.9
(12-3/4)
323.9
(12-3/4)
323.9
(12-3/4)
323.9
(12-3/4)
323.9
(12-3/4)

69.8
(2-3/4)
69.8
(2-3/4)
69.8
(2-3/45)
88.9
(3-1/2)
88.9
(3-1/2)
88.9
(3-1/2)
88.9
(3-1/2)
127
(5)
127
(5)
137.6
(5-27/64)
137.6
(5-27/64)
137.6
(5-27/64)
137.6
(5-27/64)
4-3/4
(120.6)
4-3/4
(120.6)
4-3/4
(120.6)
152.4
(6)
152.4
(6)
152.4
(6)
152.4
(6)
241.3
(9-1/2)
241.3
(9-1/2)
251.9
(9-15/16)
251.9
(9-15/16)
251.9
(9-15/16)
251.9
(9-15/16)

98.4
(3-57/64)
112.0
(4-27/64)
119.8
(4-47/64)
114.8
(4-17/32)
135.6
(5-11/32)
131.8
(5-13/64)
138.9
(5-31/64)
150.6
(5-15/16)
166.6
(6-9/16)
150.6
(5-15/16)
166.6
(6-9/16)
162.6
(6-13/32)
203.9
(8-1/32)
98.4
(3-57/64)
112.0
(4-27/64)
119.8
(4-47/64)
114.8
(4-11/34)
135.6
(5-17/32)
131.8
(5-13/64)
138.9
(5-31/64)
150.6
(5-15/16)
166.6
(6-9/16)
150.6
(5-15/16)
166.6
(6-9/16)
162.6
(6-13/32)
203.9
(8-1/32)

190.5
(7-1/2)
190.5
(7-1/2)
190.5
(7-1/2)
9-9/32
(235.7)
235.7
(9-9/32)
235.7
(9-9/32)
235.7
(9-9/32)
308.1
(12-9/64)
308.1
(12-9/64)
308.1
(12-9/64)
308.1
(12-9/64)
308.1
(12-9/64)
308.1
(12-9/64)
190.5
(7-1/2)
190.5
(7-1/2)
190.5
(7-1/2)
235.7
(9-9/32)
235.7
(9-1/4)
235.7
(9-9/32)
235.7
(9-9/32)
308.1
(12-9/64)
308.1
(12-9/64)
308.1
(12-9/64)
308.1
(12-9/64)
308.1
(12-9/64)
308.1
(12-9/64)

5.08
(2)
5.08
(2)
5.08
(2)
69.8
(2-3/4)
69.8
(2-3/4)
69.8
(2-3/4)
69.8
(2-3/4)
101.6
(4)
101.6
(4)
101.6
(4)
101.6
(4)
101.6
(4)
101.6
(4)
101.6
(4)
101.6
(4)
101.6
(4)
133.3
(5-1/4)
133.3
(5-1/4)
133.3
(5-1/4)
133.3
(5-1/4)
215.9
(8-1/2)
215.9
(8-1/2)
215.9
(8-1/2)
215.9
(8-1/2)
215.9
(8-1/2)
215.9
(8-1/2)

9.5
(25/64)
9.5
(25/64)
9.5
(25/64)
9.5
(25/64)
9.5
(25/64)
9.5
(25/64)
9.5
(25/64)
12.7
(1-1/2)
12.7
(1-1/2)
12.7
(1-1/2)
12.7
(1/2)
12.7
(1/2)
12.7
(1/2)
9.5
(25/64)
9.5
(25/64)
9.5
(25/64)
9.5
(25/64)
9.5
(25/64)
9.5
(25/64)
9.5
(25/64)
12.7
(1/2)
12.7
(1/2)
12.7
(1/2)
12.7
(1/2)
12.7
(1/2)
12.7
(1/2)

34.9
(1-25/64)
34.9
(1-25/64)
34.9
(1-25/64)
44.4
(1-3/4)
44.4
(1-3/4)

44.4
(1-3/4)

60.4
(2-25/64)
60.4
(2-25/64)
60.4
(2-25/64)
76.2
(3)
76.2
(3)
76.2
(3)
76.2
(3)

76.2
(3)

101.6
(4)
101.6
(4)
101.6
(4)
101.6
(4)
101.6
(4)
101.6
(4)

215.9
(8-1/2)
215.9
(8-1/2)
215.9
(8-1/2)
215.9
(8-1/2)
215.9
(8-1/2)
215.9
(8-1/2)

Product Selection Page 3-15 and Page 3-23

3-77

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions
Bulletin 100 Line Accessories
Dimensions are shown in millimeters (inches) and shipping weights in kg (lbs).
Dimensions are not intended for manufacturing purposes.

AC Operated Contactor With Front


Mounted Auxiliary Contact Adder
Cat. No. 195-FA

AC Operated Contactor With Pneumatic Timer


Cat. No. 196-FT
H

AC Operated Contactor With Latch Attachment


Cat. No. 197-FL
M

E
F
G

AC Operated Contactor With Surge Suppressor


Cat. No. 199-FSMA

AC Operated Contactor With Side


Mounted Auxiliary Contact Adder

Contactor with
Front Mounted Accessories
Contactor
A
B
C
D
Size
A09 and
115
144
150
100
A12
(4-17/32) (5-43/64) (5-59/64) (3-15/16)
A18 and
123
152
158
108
A24
(4-27/32) (5-63/64) (6-15/64) (4-1/4)
140
169
175
118
A30
(5-1/2) (6-21/32) (6-57/64) (4-41/64)
A38 and
156
185
191

A45
(6-9/64) (7-9/32) (7-17/32)
A60 and

A75
B110

B180

B250 and
B300

B400

B600

J
K
L

Reversing Contactor With Side Mounted


Auxiliary Contact Adder

Contactor with
Reversing Contactor with
Side Mounted Accessories
Side Mounted Accessories
E
F
G
H
J
K
L
M
57
69
114
126

(2-1/4)
(2-23/32) (4-1/2)
(4-31/32)
67
79
134
146

(2-21/64)
(3-7/64) (5-9/32)
(5-3/4)
67
79
134
146

(2-21/64)
(3-7/64) (5-9/32)
(5-3/4)
72.5
84.5
99
75
152.5
165
179
155
(2-27/32) (3-21/64) (3-57/64) (2-61/64)
(6)
(6-31/64) (7-3/64)
(6-1/64)
93
105
119
95
189
203
215
191
(3-21/32) (4-1/8) (4-11/16) (3-3/4)
(7-7/16) (7-63/64) (8-15/32) (7-33/64)
119
131
143
119
239
251
263
239
(4-11/16) (5-5/32)
(5-5/8) (4-11/16) (9-27/64)
(9-7/8) (10-11/32) (9-27/64)
134
146
158
134
245
281
293
245
(5-9/32) (5-3/4)
(6-7/32) (5-9/32) (9-21/32) (11-1/16) (11-35/64) (9-41/64)
154
166
178
154
311
322.5
334
311
(6-1/16) (6-17/32)
(7)
(6-1/16) (12-15/64) (12-45/64) (13-5/32) (12-15/64)
176
188
200
176

(6-15/16) (7-13/32) (7-7/8) (6-15/16)


255
265
275
255

(10-3/64) (10-7/16) (10-53/64) (10-3/64)

The listed Cat. Nos. are incomplete and require additional information. Refer to pages 3-38 and 3-39 listing for complete information.
Overall width with standard auxiliary contacts as supplied from Allen-Bradley.
Dimensions represent contactors with double stacked auxiliary contact blocks.
Product Selection Page 3-39
Specifications Page 3-54

3-78

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions, Continued
Bulletin 100 Line Accessories
Dimensions are shown in millimeters (inches) and shipping weights in kg (lbs).
Dimensions are not intended for manufacturing purposes.

BULLETIN
700F,
100-A09 &
100-A12

N
Q

91.4
(3-19/32)

Contactor With Terminal Lugs


Cat. No. 195-L

Contactor With Interface Module


Cat. No. 199-FIMZ

Contactor With Stab Connectors


Cat. No. 199-SC2

Contactor Size

A09 and A12


A18 and A24
A30
B110
B180
B250 and B300
B400
B600

187.3 (7-3/8)
227 (8-59/64)
292 (11-31/64)
344 (13-35/64)
430 (17-3/64)

M8 (5/16-18)
M10 (3/8-16)
M12 (1/2-13)
M12 (1/2-13)
M12 (1/2-13)

102 (4-1/64)
111 (4-3/8)
130 (5-1/8)

5.2
(13/64)

25
(63/64)

18
(45/64)

6.2
(15/64)

1 (1/32)

35
(1-3/8)
1 meter
(39-3/8)

27 (1-1/16)

7.5
(19/64)

DIN Mounting Rail


Cat. No. 199-DR1

Product Selection Page 3-39

3-79

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions, Continued
Bulletin 100 Line Accessories, Continued
Terminal Lug Kits
Dimensions are shown in millimeters (inches) and shipping weights in kg (lbs).
Dimensions are not intended for manufacturing purposes.

L
D
E

F
G
D
D

G
L

Cat. No. 199-LE1, LF1 & LG1

Cat. No.
199-LE1
199-LF1
199-LG1
199-LH1
199-LJ1

D
8.33
(21/64)
10.3
(13/32)
13.1
(33/64)
13.1
(33/64)
13.1
(33/64)

E
19.1
(3/4)
25.4
(1)
36.8
(1-29/64)

F
4.06
(5/32)
4.75
(3/16)
5.84
(15/64)

K
Cat. No. 199-LH1

G
7.11
(9/32)
9.53
(3/8)
9.53
(3/8)
19.1
(3/4)
25.4
(1)

H
9.91
(25/64)
13.8
(35/64)
19.9
(25/32)
11.2
(7/16)
17
(43/64)

J
4.06
(5/32)
4.75
(3/16)
5.84
(15/64)

K
Cat. No. 199-LJ1

K
16.8
(21/32)
21.3
(27/32)
31.8
(1-1/4)
63.5
(2-1/2)
90
(3-9/16)

L
16
(5/8)
22.2
(7/8)
32.3
(1-17/64)
53.3
(2-7/64)
60.5
(2-3/8)

Terminal Pads for Contactors and Current Transformer Overload Relays

B
Anti-Rotation
Pocket (2)

Cat. No.
100-B110 & 193-HPD
100-B180 & 193-DPD
100-B250 & B300
193-EPD
100-B400 & 193-FPD
100-B600 & 193-GPD

Product Selection Page 3-39

3-80

A
115
(19/32)
20
(25/32)
32
(1-17/64)
35
(1-3/8)
50
(1-31/32)

B
10
(25/64)
13.8
(35/64)
18.1
(23/32)
19
(3/4)
27
(1-1/16)

C
3.18
(1/8)
4.75
(3/16)
4.75
(3/16)
5
(13/64)
5
(13/64)

D
8.41
(21/64)
10.4
(13/32)
13
(33/64)
13
(33/64)
13
(33/64)

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions, Continued
Bulletin 100 Line Accessories, Continued
Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
Flexible Connector Kits
M

Cat. No.
199-PCE1
199-PCF1
199-PCG1
Qty 1
199-PCH1
Qty 2
199-PCJ1

8.74
(11/32)
10.3
(13/32)
12.7
(1/2)
12.7
(1/2)
12.7
(1/2)
12.7
(1/2)

127
(5)
153
(6-3/64)
170
(6-11/16)
226
(8-29/32)
164
(6-15/32)
284
(11-13/64)

108
(41-1/4)
128
(5-3/64)
144
(5-9/16)
191
(7-17/32)
129
(5-5/64)
241
(9-1/2)

9.53
(3/8)
12.7
(1/2)
14.2
(9/16)
17.5
(11/16)
17.5
(11/16)
21.3
(27/32)

15.9
(5/8)
19.1
(3/4)
26.9
(1-1/16)
34.9
(1-3/8)
34.9
(1-3/8)
38.1
(1-1/2)

3.18
(1/8)
3.56
(9/54)
5.59
(7/32)
4.95
(13/64)
4.95
13/64)
6.6
(17/64)

External Reset and Reset Adapter

32 Min.
(1-17/64)
15
(19/32)

20
(51/64)

117 Max.
(4-19/64)
Max. 14 (35/64)
Min. 9 (11/32)

Mechanical/Electrical Interlocks

40
(1-9/16)

13
(33/64)

Cat. No. 199-MCA1

21
(53/64)

Cat. No. 199-MCD1

Cat. No. 199-MXH1 & MXJ1


(Mechanical Only)

3-81

Bulletin 100 Line

IEC Dimensions
Approximate Dimensions, Continued
Bulletin 199 Wye-Delta (Star-Delta) Starter Kits
Dimensions are shown in millimeters (inches) and shipping weights in kg (lbs).
Dimensions are not intended for manufacturing purposes.
A

M1
S1

M2
B

C
D
E

A
Wide

B
High

C
Deep

Approx.
Ship Wt.

250
(9-27/32)
250
(9-27/32)
300
(11-13/16)

140
(5-1/2)
165
(6-1/2)
191
(7-1/2)

99
(3-29/32)
104
(4-3/32)
100
(3-15/16)

144
(5-43/64)
152
(5-63/64)
169
(6-21/32)

194
(7-5/8)
219
(8-5/8)
229
(9)

0.454
(1)
0.454
(1)
0.908
(2)

Cat. No.
199-YD1
199-YD2
199-YD3

B
D

Cat. No.
199-YD4
199-YD5
199-YD6
199-YD7
199-YD8

22.10
(7/8)
TYP

Mounting
Screw

Approx.
Ship. Wt.

280
(11-1/32)
312
(12-9/32)
550
(21-21/32)
723.9
(28-1/2)
876
(34-1/2)

250
(9-27/32)
284
(11-3/16)
385
(15-3/16)
421.1
(16-9/16)
491
(19-5/16)

268
(10-9/16)
300
(11-13/16)
530
(20-7/8)
700
(27-9/16)
850
(33-1/2)

234
(9-7/32)
268
(10-9/16)
350
(13-25/32)
380
(14-15/16)
450
(17-3/4)

44.5
(1-3/4)
31.8
(1-1/4)

136
(5-5/16)
158
(6-3/16)
182
(7-1/8)
277
(11-3/32)
292
(11-11/16)

5.51
(7/32)
5.51
(7/32)
7.19
(9/32)
10.3
(13/32)
12.3
(1/2)

2.27
(5)
2.724
(6)
11.34
(25)
27.69
(61)
42.68
(94)

Product Selection Page 3-9

3-82

You might also like