HAWS COMPACT WALL-MOUNTED WATER COOLERS

Models HWS4, HWS8, HWS13


Compact wall mounted models are
designed to leave the floor free for
easy cleaning and only extend W/%"
from the wall. A variety of color
finishes give the specifier the ability
to complement the building decor.
CABINET
Manufactured of heavy-gauge steel
with vinyl protective coating on the
front and sides. Resistant to wear,
moisture, perspiration, heat and sun-
light. Also available in stainless steel
and stainless steel with Sienna
Bronze finish
COOLER TOP
Anti-splash ridge reduces splatter.
Contour design ensures proper
drainage and prevents standing
waste water. Stainless steel top with
bright finish resists stains and cor-
rosion and is easy to maintain.
BUBBLER
One
:
piece, chrome-plated, shielded,
anti-squirt, angle stream designed tb
prevent contamination from other
users and air-borne deposits.
VALVE/STREAM REGULATOR
The self closing push button
operated combination valve and
screwdriver adjusted regulator is lo-
cated inside cabinet to prevent
tampering. A constant stream height
is automatically maintained under
lime pressures that vary from 20 to
150 PSl.
EVAPORATOR/CHILLER WATER
Design combines counterflow cool-
ing with efficient bonding of the
refrigerant and water coils for maxi-
mum heat transfer. All-copper con-
struction meets government and
commercial sanitation requirements.
PRECOOLER
(Models HWS8 & HWS13 Only)
Increased efficiency boosts capacity
by 60%. Double-wall construction
has incoming water line coiled
around and bonded to cold water
drain line. 1" (approx.) free-flow area
throughout drain line reduces
chance of clogging.
TEMPERATURE CONTROL. -
Positive' sensing thermostat for con-
trolling temperature of evaporator/
chiller storage water. It is factory set
50T. Adjustable 5T.
Standard Finish is Sahara Vinyl.
OPTIONAL FINISHES
Almond Vinyl
Walnut Vinyl
Stainless Steel (Extra Cost)
Q Stainless Steel with Sienna
Bronze finish. Add "B" to
model number (Extra Cost.)
FAN MOTOR
Unit bearing self-lubricating type for
maintenance-free longer life.
CONDENSER
Copper/aluminum construction.
INSULATION SYSTEM
Evaporator/chiller employs totally en-
capsulated construction of high ef-
ficiency EPS for maximum insulating
characteristics.
REFRIGERATION SYSTEM
System balance, lower energy
usage, and longer life assured by
utilizing high displacement compres-
sor, counterflow cooling evaporator/
chiller, efficient capillary sizing, large
capacity dryer-strainer, fan-cooled
condenser with maximum heat ex-
change. Hermetically sealed, posi-
tive start compressor with lifetime
lubrication and built-in overload
protection. System completely
sealed after deep evacuation,
'dehydration, and pressure testing
at 250 PSIG.
WATER COOLERS
HAWS DRINKING FAUCET COMPANY
33
HEIDEMANN
Ingenir & Handelsfirma ApS Telefon (+45) 98 42 20 30
Sndergade 242 9900 Frederikshavn
IMO 9146455
L163
HAWS COMPACT WALL-MOUNTED WATER COOLERS
Models HWS4, HWS8, HWS13
r
MOUNTING INSTRUCTIONS
Mount trap and hanger bracket and
install union connection/service stop
to building supply line. To ensure
proper engaging of waste line into
trap, center line of trap must be 7
7
/8"
from wall face. Remove slip nut and
gasket from trap and install on waste
line tube. Hang cooler on bracket
and engage waste line tube into trap
inlet. Centerline height of waste out-
let is 31VV from floor line for conven-
tional adult installation. A service
stop (not furnished) is recommended
and 4" clearance on sides of unit for
proper air circulation.
ELECTRICAL
Furnished with plug-in, 3-wire
grounding type service cord; 120
volt, 60 Hz, single phase.
PLUMBING CONNECTIONS '-
Waste: 1V4" OD tailpiece.
Supply:W FPT combination inlet fit-
ting and strainer.
OPTIONAL ACCESSORIES
(Extra Cost)
Cold water giassfiller (specify
model), mounted on left rear. For,
more information, see page 75.
7(378J_
__-HANGER
BRACKET
[Ilt DITAII-A]
WATER INLET 1
STAIN ER 3/8"STD.
FEMALE PIPE THD.
RECOMMENDED HEIGHT
ADULTS 0-1/3 005?)
YOUNGSTERS 33-1/2 (?51)
FROM FLOOR LINE
6 HOLES,] EA. END
Jjft DIA.
H3130 H3140
/
fi
FRONT VIEW
HANGER BRACKET
ORAIN PIPE l j OD
SUP JOINT
CONNECTION
WATE SUPPLY LINE
DRAIN TRAP -
^[NOT fUlNUHID]..
SHUT-OFF VALVE
ALTERNATE LOCATION
4- FOR DRAIN TRAP AND
WATER SUPPLY LINE
DETAIL- A
Model
Number
HWS4
HWS8
HWS13
C
o
m
p
r
e
s
s
o
r
S
i
z
e

&

C
o
n
d
e
n
s
i
n
g
M
e
d
i
u
m
Ve AIR
Ve AIR
Ms AIR
W
a
t
t

U
s
a
g
e
249
246
395
to
Q.
3.7
3.7
C
o
l
d

W
a
t
e
r

j
G
i
a
s
s
f
i
l
l
e
r
O
p
t
i
o
n

j
/
/
4.7 I /
2
2
0
V
-
5
0

H
z

O
p
t
i
o
n

j
/
/
H x W x D
(in inches)
Shipoing
Dimensions
25X18X19
25X18X 19
25X18X19
S
h
i
p
p
i
n
g

j
W
e
i
g
h
t
-
I
b
s
.

j
59
61
64
C
u
b
i
c

F
e
e
t
4.9
4.9
4.9
r
INLET
WATER
Amblenl
Temperature
HWS4
HWS8
HWS13
70T (21'C)
70'F
(21X)
79
127
20 6
80'F
(27-C)
76
121
19 7
90'F
(32X)
I 70
112
182
100T
(38X)
62
103
164

l
-80T(2TC) .>
7O'F
(21-C)
56
9.1
147
80T
(27-C)
54
87
14 0
OTf
(32-C)
5.0"
8.0
13 0
100'F
(38-C)
45
72
117
90'F (32
-
)
7O'F
(21-C)
42
68
80T
(27-C)
40
90'F
(32-C)
33
6 5 . 50
110 | 10.5 97
100T
(38'C)
34
54
Base
Rate
50
8 7 I 80
GPH dnnking water delivered at 50'F (10'C) based on 60% spill through pre-cooler.
To convert inches to centimeters multiply inches by 2.54.
To convert gallons to liters multiply gallons by 3.785.
ALL WATER-BEARING MATERIALS COMPLY WITH THE SAFE
DRINKING WATER ACT OF 1986 AND THE LEAD CONTAMINATION
CONTROL ACT OF 1988.
WARRANTY
Five-year warranty protects refrigeration system. Ask for cur standard
warranty policy detailing our complete and specific liabilities.
UL listed and certified by ARI to meet Standard 1010-84
Note: Continued product improvement makes specifications
subject to change without notice.
H3139 H3105
r
WATER COOLERS
34 HAWS DRINKING FAUCET COMPANY
1435 4th Street P.O. Box 1999
Berkeley, CA 94701 Telex 33-6358
Phone: (415)525-5801
FAX: 415-528-2812
HF 4, 8, 10 & 14
>'. l l - ,
I t
_ MX I"

^r
M1
WATZR INUT *
STRAINER f STOL
FEMALE PIPE THIl
Tj L- ^ ] SLIP JUIN
J l f J l ONNIXTION
I
L
ATitt si r m
FRONT VIEW RK.HT MDL VILW
|V ^
Wall Hung
HW8 & 14
3 HEJCHT
ADULTS 40* 11016t
V^UNCSTERS
siSjty fLOOR UNE
\ . t ,,
< ',
HSF 14
Children Heights
FRONT PANEL
HOLDINt. St KIW\
DRAIN PI f t
I iv,(i.n
SLIPIOIN
) CONNECTION
A T M'PPD
f DRAIN TRAP
(NOT FURNIMtED)
RICHT DE VIEW
Compact Wall Hung
HWS 4, 8 & 13
RECOMMENDED HEICHT
ADULTS *0 'T 410291
YDUNCSTEBS ) ] ' { - | l l
FROM FLOOR LINE
HANCER
BRACKET
WATER INLET
STRAINER /; STDi
FEMALE PIPE THD
WASTE OUTLET
WATER SUfPLY
- AIR LUUVERS
MITH SIDES
MOUNTING FRONT fANEL T
CLIPS HOLO1NC SCREWS _^2
ELECTRIC OUTLET |5H
1NOT FURNISHED!
I. HOLES. 1 EA END
"( 1DIA.
FHONT VIEW
RtCHT SIDE VIEU
- HANCER BRACKET
DRAIN PIPE
SUP IOINT
CONNECTION
WATER SUPPLY LINE
DRAIN TRA?
s
(N0TFURNI$HED1
SHUTOFF VALVE
A1TERNATE LOCATION
FOR DRAJN TRAP AND
WATER sur rut UNE
Flush to Wall
Explosion Proof
HFX16W
I1KA1N PIPE
',7 O.D
SLIP IOINT
CONNECTION
WATER SUPPLY
DRAIN TRAP
(NOT FURNISHED!
SHUT(IFF VALVE
RIGHT SIDE VIEW
HAWS Water Cooler Owners Manual
INSTALLER PLEASE LEAVE WITH COOLER
This manual provides installation, maintenance and trouble shooting
guide for the following basic water cooler models:
HF-4, -8, -10, -14 * HWS-4, -8 & 13
HW-8, -14 HFX16W
READ THESE INSTRUCTIONS BEFORE STARTING INSTALLATION
IMPORTANT
I. Safety Precautions
A. Do not allow water to come into contact with
live electrical wires because short circuiting
and shocks can occur.
B. WARNING Beware of rotating fans when
covers are removed.
C. Care should be taken not to puncture refrigera-
tion system lines. Some lines contain gas under
high pressure.
D. Install cooler to conform with all applicable
codes, including the National Electrical Code.
H. Installation
A. WATER SUPPLY The water cooler is fitted
with a
3
/g F.PT. inlet fitting strainer, as shown
on the installation drawings. Connecting lines
must be thoroughly flushed to remove all dirt
and debris before connection to the copier.
Warranty claims will not be accepted if the inlet
strainer, coil or valve are blocked with foreign
matter.
These coolers are fitted with a remote connec-
tion. (Do not connect supply line to this fitting
as.it will allow the inlet water to bypass the
cooling coil; therefore not giving cold water at
the bubbler.)
B. DRAIN CONNECTION l
1
^' I.P.S. - The in-
staller must provide a waste trap and install in
accordance to local codes.
C. ELECTRICAL CONNECTIONS
1. Check first to make sure electrical (supply)
voltage is the same as shown on the cooler
serialnameplate. If not the same, do not con-
nect to the electrical supply because major
damage could result.
2. The water cooler must be protectively grounded.
Make sure the supply connection is provided
with a protective grounded wire. Do not use
the cooler if ground wire is not connected.
3. Connect the cooler only by the lead provided.
Do not wire direct to the compressor.
D. VENTILATION
To maintain proper ventilation.and correct func-
tioning of the water cooler a 4" clearance is
required on each side of the cooler louvers.
Failure to comply could cause the compressor
to fail and therefore void the warranty.
E. INSTALLATION OF COOLER
The drawings provided with these instructions
show the cooler dimensions, location of all the
required services and mounting instructions for
the wall hung models. The installer is respon-
sible for providing the drain trap and shut off
valve.
F. CONDENSER FAN
Before plugging unit into electrical supply make
sure fan rotates freely. Failure to check free fan
movement can cause compressor failure, voiding
the warranty.
G. ADJUSTMENTS
The water flow cartridge and thermostat are set
at the factory. Adjustments, if required, should
be done in accordance with these instructions
(Maintenance] and by a trained technician.
III. Maintenance
A. GENERAL .
Any work carried out inside the cabinet (once
front panel is rernoved) must be done by a
qualified technician who is aware of the
hazards.
B. MAINTENANCE
1. For appearance and hygiene, it is recommended
that the top and cabinet be cleaned regularly
with a mild cleaning agent.
2. Keep the air flow vents clean and free from
paper, debris and dust to assure good operation
C. WATER FLOW ADJUSTMENTS
Access to the cartridge flow regulator is gained
by removing the front panel. (See drawing pro-
vided). The location of the cartridge is in the
upper left hand corner of the cabinet. Adjust-
ments can be made through the hole provided
with a small screw driver. A clockwise rotation
increases the flow rate. An ideal stream height
is approximately 6" above top of drain receptor.
Adjustments to this cartridge are not covered
by the warranty.
D. TEMPERATURE CONTROL THERMOSTAT
This control is located inside front panel and
is factory set at 45 F. For colder water, adjust
the screw in a clockwise direction.
E. STORAGE OF COOLER If location of
cooler is such that it is subjected to freezing
temperature, care should be taken to complete-
ly drain the drinking water storage chamber.
Water cooled models must also have the water
condenser coils completely drained.
WARRANTY
Warranty certificate provided with the cooler tells what
to do in the unlikely event of a failure of your cooler. Ad-
justment to flow ana water temperature are not covered by
the warranty. For detailed information concerning the
maintenance and repair of your water cooler,* contact the
factory and request an instruction Manual.
PMX-552 11/85
- 1
MODELS APPLIED
J

\
COMPONENT
COMPRESSOR
OVERLOAD
RELAY
RELAY/OVERLOAD
FAN MOTOR
FAN BLADE
THERMOSTAT
BUBBLER SPOUT
CARTRIDGE
CONDENSER
CONDENSER
CONDENSER
WATER VALVE
STRAINER SCREEN
PUSH BUTTON
SPRING
ROD DUAL ONLY
DRAIN WASHER
EVAPORATOR
HOT TANK ASSY
HOT THERMOSTAT
HOT TANK O/L
HOT VALVE
HOT TANK SWITCH
PART NO.
A019055
A019703
A019840
A018265
A019065
A019705
A019841
A019064
A019706
AD 19842
AO18606
B153475
A016338
A016241
C026018
B153468
C026102
C026101
C026104
A016492-01
A019489
A017272-01
A016837
AO16368
AO15671
C026072
D035704
A019285
AO19371
B153497
A019247
HF
4

e
o

HF
8

HF
10

9
e
e

HF
14

o
e
e

HW
8

HW
14

9
9
9
9
e

HWS
4

e
HWS
8

9
9
9
HWS
13
9
HFX
16W
)
|
I :
i i
I i
1 !
0
I
i
i
!
9
9
9
9
e
I
9 !
9
e
9
9
9
e
NOTE: For water cooled models and other parts not shown, contact the factory. (415) 525-5801
ISIC TROUBLE SHOOTING
1. WATER DRIBBLES OR FLOWS
CONTINUOUSLY
A Di n in canndge Replace
canndge
B. Mechanism jammed Check
and remove restriction
C. Bad cartridge Replace
2. NO WATER FLOW
A Blocked inlet screen Clean or
replace
B. Water supply OFF Turn ON
C. Frozen Coils Bad thermostat
or short cycling compressor
Call service man.
D. Bad cartridge Replace
3. NOT COOLING
A. Thermostat turned to OFF
position Reset to ON
position
B. Electric supply failure or blown
fuse Reenergize or replace
fuse.
C. Refrigeration failure Call
service man.