You are on page 1of 2

T

h
e

i
n
f
o
r
m
a
t
i
o
n

p
r
o
v
i
d
e
d

i
n

t
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

c
o
n
t
a
i
n
s

g
e
n
e
r
a
l

d
e
s
c
r
i
p
t
i
o
n
s

a
n
d
/
o
r

t
e
c
h
n
i
c
a
l

c
h
a
r
a
c
t
e
r
i
s
t
i
c
s

o
f

t
h
e

p
e
r
f
o
r
m
a
n
c
e

o
f

t
h
e

p
r
o
d
u
c
t
s

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
T
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

i
s

n
o
t

i
n
t
e
n
d
e
d

a
s

a

s
u
b
s
t
i
t
u
t
e

f
o
r

a
n
d

i
s

n
o
t

t
o

b
e

u
s
e
d

f
o
r

d
e
t
e
r
m
i
n
i
n
g

s
u
i
t
a
b
i
l
i
t
y

o
r

r
e
l
i
a
b
i
l
i
t
y

o
f

t
h
e
s
e

p
r
o
d
u
c
t
s

f
o
r

s
p
e
c
i
f
i
c

u
s
e
r

a
p
p
l
i
c
a
t
i
o
n
s
.
I
t

i
s

t
h
e

d
u
t
y

o
f

a
n
y

s
u
c
h

u
s
e
r

o
r

i
n
t
e
g
r
a
t
o
r

t
o

p
e
r
f
o
r
m

t
h
e

a
p
p
r
o
p
r
i
a
t
e

a
n
d

c
o
m
p
l
e
t
e

r
i
s
k

a
n
a
l
y
s
i
s
,

e
v
a
l
u
a
t
i
o
n

a
n
d

t
e
s
t
i
n
g

o
f

t
h
e

p
r
o
d
u
c
t
s

w
i
t
h

r
e
s
p
e
c
t

t
o

t
h
e

r
e
l
e
v
a
n
t

s
p
e
c
i
f
i
c

a
p
p
l
i
c
a
t
i
o
n

o
r

u
s
e

t
h
e
r
e
o
f
.
N
e
i
t
h
e
r

S
c
h
n
e
i
d
e
r

E
l
e
c
t
r
i
c

I
n
d
u
s
t
r
i
e
s

S
A
S

n
o
r

a
n
y

o
f

i
t
s

a
f
f
i
l
i
a
t
e
s

o
r

s
u
b
s
i
d
i
a
r
i
e
s

s
h
a
l
l

b
e

r
e
s
p
o
n
s
i
b
l
e

o
r

l
i
a
b
l
e

f
o
r

m
i
s
u
s
e

o
f

t
h
e

i
n
f
o
r
m
a
t
i
o
n

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
Feb 14, 2012
1
Product data sheet
Characteristics
LV429633
circuit breaker Compact NSX100F - TMD - 50
A - 3 poles 3d
Main
Device short name Compact NSX100F
Circuit breaker applica-
tion
Distribution
Poles description 3P
Protected poles de-
scription
3t
Network type AC
Network frequency 50/60 Hz
[In] rated current 100 A ( 40 C )
[Ui] rated insulation
voltage
800 V AC 50/60 Hz
[Uimp] rated impulse
withstand voltage
8 kV
[Ue] rated operational
voltage
690 V AC 50/60 Hz
Circuit breaker rating
code
F
Breaking capacity Icu 22 kA at 525 V AC 50/60 Hz conforming to IEC
60947-2
Icu 8 kA at 660/690 V AC 50/60 Hz conforming to
IEC 60947-2
Icu 85 kA at 220/240 V AC 50/60 Hz conforming to
IEC 60947-2
Icu 36 kA at 380/415 V AC 50/60 Hz conforming to
IEC 60947-2
Icu 35 kA at 440 V AC 50/60 Hz conforming to IEC
60947-2
Icu 25 kA at 500 V AC 50/60 Hz conforming to IEC
60947-2
85 kA at 240 V AC 50/60 Hz conforming to NEMA
AB1
35 kA at 480 V AC 50/60 Hz conforming to NEMA
AB1
8 kA at 600 V AC 50/60 Hz conforming to NEMA
AB1
85 kA at 240 V AC 50/60 Hz conforming to UL 508
25 kA at 480 V AC 50/60 Hz conforming to UL 508
10 kA at 600 V AC 50/60 Hz conforming to UL 508
[Ics] rated service
breaking capacity
Ics 4 kA 660/690 V AC 50/60 Hz conforming to IEC
60947-2
Ics 11 kA 525 V AC 50/60 Hz conforming to IEC
60947-2
Ics 12.5 kA 500 V AC 50/60 Hz conforming to IEC
60947-2
Ics 35 kA 440 V AC 50/60 Hz conforming to IEC
60947-2
Ics 36 kA 380/415 V AC 50/60 Hz conforming to IEC
60947-2
Ics 85 kA 220/240 V AC 50/60 Hz conforming to IEC
60947-2
Suitability for isolation Yes conforming to IEC 60947-2
Yes conforming to EN 60947-2
Utilisation category Category A
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit rating 50 A ( 40 C )
Protection type Overload protection (thermal)
Short-circuit protection (magnetic)
Pollution degree 3 conforming to IEC 60947-1
2
Complementary
Control type Toggle
Mounting mode Fixed
Mounting support Backplate
Upside connection Front
Downside connection Front
Mechanical durability 50000 cycles
Electrical durability 50000 cycles 440 V In/2 conforming to IEC 60947-2
30000 cycles 440 V In conforming to IEC 60947-2
20000 cycles 690 V In/2 conforming to IEC 60947-2
10000 cycles 690 V In conforming to IEC 60947-2
Connection pitch 35 mm
Local signalling Positive contact indication
Long time pick-up adjstment type Ir Adjustable
Long time pick-up adjustment range 0.7...1 x In
Long time delay adjustment type Fixed
[Tr] long-time delay adjustment 15 s 6 x Ir
120...400 s 1.5 x In
Short-time pick-up adjustment type Isd Fixed
[Isd] short-time pick-up adjustment range 500 A
Short-time delay adjustment type Fixed
Height 161 mm
Width 105 mm
Depth 86 mm
Environment
Electrical shock protection class Class II
Standards EN 60947-2
IEC 60947-2
NEMA AB1
UL 508
Product certifications CSA
UL
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to EN 50102
Ambient air temperature for operation -35...70 C
Ambient air temperature for storage -55...85 C
RoHS EUR conformity date 0819
RoHS EUR status Compliant

You might also like