You are on page 1of 4

DIRIS A10 Multifunction meter

NEW
diris_791_b_1_cat

‹ Applications
Multiple
measurement
• Current

site_321_a
- instantaneous: I1,
I2, I3, In
- maximum:
Modular measurement meter I1, I2, I3, In
• Voltages & frequency
- instantaneous: DIRIS A10 RS485 DIRIS A10

U1, U2, U3, U12,


‹ Function 485
U23, U31, F 232 Main
meter panel
The DIRIS A10 is a multifunction meter for • Power
measuring electrical values in low voltage - instantaneous: 3P,
networks in modular format. It allows all ΣP, 3Q, ΣQ, 3S, ΣS PC diris_808_a_1_gb_cat
electrical parameters to be displayed and - maximum: Currents
per phase
the measurement, energy metering and ΣP, ΣQ, ΣS PLC curve

communication functions to be used. • Power factor


In addition, the DIRIS A10 has a function - instantaneous:
for correcting errors in CT connections. It 3PF, ΣPF CONTROL VISION software
also allow variations in temperature to be
detected thanks to its internal temperature Metering Events
measurement function. • Active energy: + kWh Alarms on all electrical
• Reactive energy: + kvarh values
• Hours:
Communications (1)
Total harmonic distortion RS485 (JBUS/MODBUS)
• Harmonic analysis (level 51) digital
- Currents: thd I1, thd I2, thd I3
‹ Conformity to standards - Phase-to-neutral voltage: Output
• IEC 62053-22 class 0,5 S thd U1, thd U2, thd U3 • Control of devices
• IEC 62053-23 class 2
- Phase to phase voltage: • Alarm report
• IEC 61557-12
thd U12, thd U23, thd U31 • Pulse report

 vailable as an option
(1) A
(see the following pages).

 General Catalogue 2008-2009 SOCOMEC


Multifunction meter
DIRIS A10

‹ Front panel

1. Backlit LCD display.


2. Direct access key for currents (instantaneous and max. values),
current THD and set up wiring correction.
3. Direct access key for voltages, frequency and voltage THD.
4. Direct access key for active, reactive and apparent power
(instantaneous and max. values) and power factor.
2 5. Direct access key for energies and hour meter.
3 6. Pushbutton for currents, temperatures and CT setup wiring
4 correction.
5 7. Flashing led consumption.
diris_791x_b_2_cat

6
7

‹ Case
64
72 44
Type Modular
Number of modules 4
Dimensions W x H x D 72 x 90 x 64 mm
DIRIS A 10 Case protection rating 30
I
V F
TEST
Front protection rating 52
Display type LCD
45
90

P PF
E OK

°C PROG
Voltag and current correction 4 mm2
diris_809_a_1_x_cat

C=0,1Wh/imp
Others correction 2,5 mm2
Weight 205 g (4825 0210) - 215 g (4825 0211)

‹ Electrical Characteristics

Current measurement on insulated inputs (TRMS) Energy accuracy


CT primary 9 999 A Active (according to IEC 62053-22) class 0.5 S
CT secondary 5A Reactive (according to IEC 62053-23) class 2
Measurement range 0 … 11 kA
Input consumption 0,6 VA
Auxiliary supply
Measurement updating period 1s
AC voltage 200 … 277 VAC
Accuracy 0,2 %
AC tolerance ± 15 %
Sustained overload 6A
Frequency 50 / 60 Hz
Intermittent overload 10 In for 1 s
Consumption < 3 VA
Voltage measurements (TRMS)
Direct measurement between phases 50 … 500 VAC
Direct measurement between phase and neutral 28 … 289 VAC Outputs (Pulse)
Input consumption ≤ 0,1 VA Number 1
Mesaurement updating period 1s Type 100 VDC - 0.5 A - 10 VA
Accuracy 0,2 % Max. number of operations ≤ 108
Sustained overload 800 VAC
Power measurement Communication
Mesaurement updating period 1s Link RS485
Accuracy 0,5 % Type 2 … 3 half duplex wires
Power factor measurement Protocol JBUS/MODBUS® in RTU mode
Mesaurement updating period 1s JBUS/MODBUS® speed 1400 … 38400 bauds
Accuracy 0,5 %
Frequency measurement Operating conditions
Measurement range 45 … 65 Hz Operating temperature - 10 … + 55°C °C
Measurement updating period 1s Storage temperature - 20 … + 70°C °C
Accuracy 0,1 % Relative humidity 85 %

SOCOMEC General Catalogue 2008-2009 


‹ Connection
Low voltage balanced network

Recommendation:
- For IT earthing systems, it is recommended that the CT secondaries are not connected to the earth.
- While disconnecting the DIRIS, the secondaries of each current transformer must be short-circuited. This operation can be carried out automatically from a product in the SOCOMEC
catalogue, PTI: Please consult us.
- It is recommended that the earthing point for the DIRIS A10 and the current transformer secondaries must not earthed at the same time.

3/4 wires with 1 CT Single phase Two phase

1 = Fus. 0.5 A gG / 0.5 A class CC 1 = Fus. 0.5 A gG / 0.5 A class CC 1 = Fus. 0.5 A gG / 0.5 A class CC

N P1 P1
P1 L1 L1
L1 S1 S2 S1 S2
S1 S2 N L2
L2
L3

1 1 1 1 1 1
diris_810_a_1_gb_cat

diris_811_a_1_gb_cat

diris_812_a_1_gb_cat
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2

I1 I2 I3 I1 I2 I3 I1 I2 I3

Connection - Low voltage unbalanced network

3/4 wires with 3 CTs 3 wires with 2 CTs 3 wires with 2 CTs

1 = Fus. 0.5 A gG / 0.5 A class CC 1 = Fus. 0.5 A gG / 0.5 A class CC 1 = Fus. 0.5 A gG / 0.5 A class CC

N P1
L1 P1
L1
P1 S1 S2
L1 L2
S1 P1
L2
S1 S2
L2 P1
L3
S1 S2
L3
P1
L3 S1 S2
S1 S2

1 1 1 1 1 1
1 1 1
diris_813_a_1_gb_cat

diris_814_a_1_gb_cat

diris_815_a_1_gb_cat

V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3 I1 I2 I3 I1 I2 I3

Use of 2 CTs reduces by 0.5 % the accuracy of Use of 2 CTs reduces by 0.5 % the accuracy of
the phase, whose current is worked out by vector the phase, whose current is worked out by vector
calculation. calculation.

Other information

Communication via RS485 link AC & DC auxiliary power supply

220/ 277 VAC (IEC)

LIYCY-CY
diris_820_a_1_x_cat

0V - +
diris_821_a_1_x_cat

20 22

RS485 AUX

It is recommended that the auxiliary power supply be


protected by the use of 500 mA gG fuses.

 General Catalogue 2008-2009 SOCOMEC


Multifunction meter
DIRIS A10

‹ Terminals

12 14 16 2 20 22 1 3 5 7 9 11 18
diris_816_a_1_x_cat

V1 V2 V3 VN A U X S1 S2 S1 S2 S1 S2

I1 I2 I3

DIRIS A10
S1 - S2: current inputs.

AUX: auxiliary power supply Us.


V1, V2, V3 & VN: voltage inputs.

Communication module Output or alarm module Input module

1 3 15 17 4 6 8 10
diris_817_a_1_x_cat

diris_819_a_1_x_cat

diris_818_a_1_x_cat
0V + -
OUT 1 IN 1
RS485

DIRIS A10 DIRIS A10 DIRIS A10


RS485 link. 4 - 6: output n°1. 8 - 10: input no. 1.

‹ References

diris_791_b_3_cat

Switches DIRIS A10


Description Reference
DIRIS A10 4825 0010
DIRIS A10 with RS485 JBUS/MODBUS communication 4825 0011

SOCOMEC General Catalogue 2008-2009 

You might also like