You are on page 1of 8

NOW STOCKING: LIGHTNING PROTECTION

Where do you turn for lightning


protection expertise and certification?
Downconductors & Cable Fasteners
Air Terminals & Adaptors
Connectors, Clamps, Plates & Lugs
Through Roof, Through Wall & Cable Protectors
Bonding & Grounding Accessories (CADWELD)
Surge Protection (CRITEC)
Lightning Protection Software
Design ACAD Drawings
Lightning Protection Training Seminars

Installation Certification
ERICO will complete a takeoff of all lightning
protection products and will provide a design
and a bill of material. Once the installation is
complete, ERICO will coordinate with UL or
LPI to obtain a 3rd Party Certification.
What we need from you:
Roof Plan
Exterior Elevations
Specifications

your first, last and only source

is right around the corner

As your work sites best friend, we support you with expansive tool lines and in-stock
solutions, ready for delivery or pick-up at one of our seven convenient locations.

St. Louis County

Tool Repair
Lighting Design
Distribution Equipment
Training Classes
Specialty Fastening
Job Management

2429 Schuetz Road


Maryland Heights, MO 63043

Ammonette St

70

St. Clair County, IL


N Bluff Rd

Horseshoe Lake Rd

55

70

rce Ln

20 Commerce Lane
Lebanon, IL 62254

157

Business Center Ct

Comme

#2 Business Center Court


Collinsville, IL 62234

Branch Manager: Dirk Baecht


Dirk.Baecht@FrostSupply.com

Vandiver Dr

Monroe St

Madison County, IL

Phone: 618-345-7255
Fax: 618-345-2584

Phone: 573-886-9777
Fax: 573-886-0790

Fe P l

Rd

Business Loop 70 E

Santa

1809 Santa Fe Place


Columbia, MO 65202

70

Old Rt 63

Branch Manager: Joe Erard


Joe.Erard@FrostSupply.com

70

Mid-MO Tool, Fastening & Safety

Pa
ris

Phone: 573-875-4151
Fax: 573-875-4240

a Ln

Elaine Dr

Branch Manager: Jim Smith


Jim.Smith@FrostSupply.com

40

W Terr

N Central Dr

Phone: 636-379-2850
Fax: 696-379-2871

Mid-Missouri
1711 Paris Road
Columbia, MO 65201

88 North Central Drive


OFallon, MO 63366

Bryan Rd

Clark A
ve

64

e r s on

Walnu
t Pl

Ave

Market St

Rangeli
ne S t

Branch Manager: Al Asberry


Al.Asberry@FrostSupply.com

St. Charles County

S J ef f

Phone: 314-535-5070
Fax: 314-535-5289

270

Page Ave

St. Louis City


2720 Walnut Place
St. Louis, MO 63103

Schuetz Rd

Phone: 314-567-4004
Fax: 314-997-5776

Dorsett Rd

Phone: 618-206-1900
Fax: 618-206-1903

50
64
158

Tools Anchoring Fastening & Hanging Systems Accessories Concrete Products


Electrical Lighting Voice & Data Industrial Automation Utility & Linemans Gear Safety

50

ERICO
Re:

22 Plex Office
Job No: GA-132991
Date: 3/27/2013
PRELIMINARY
LIGHTNING PROTECTION ITEMIZED QUOTE

Qty.
Part No.
Cable and Fasteners
1100 LPA100250
50 LPA141250
150 LPC120250
330 LPA810
120 LPA805
LPP899
120 A927P023
Air Terminals and Bases
36 LPA222ST
36 LPA30212
Splicers
20 LPA505
4
LPA501
6
LPC502A
LPC505
LPC501
2
LPC517
Bonds
6
LPA556
6
A927F179
6
A928K011
LPA540
Pipe Bonds
LPA580
LPA5962
LPA5963
LPA5964
LPA5966
LPA588
LPA590
LPC580
LPC5962
LPC5963
LPC5964
LPA5966
LPC588
LPC590
Grounding
6
615800
1
GTC168C
1
115PLUSF20
1
GYE162Q
1
150PLUSF20
1
PLUSCU
1
EGRD58
1
T403
1
T396

Description

Price

Total

Cable, Smoothweave, Alum, 24 x 14 Gauge


Soft Solid Round, Alum, 4 AWG
Cable, Smoothweave, Cu, 29 x 17 Gauge
Al. Stamped Adhesive Cable Holder
Al. 5/8" Cable Strap, One Hole

$
$
$
$
$

0.87
0.61
2.30
0.49
0.36

$
$
$
$
$

957.00
30.45
345.00
161.70
43.22

SCREW,SHEET METAL,#10X5/8

0.30

36.04

Air Term, Al. 1/2" x 12" Safety Tipped


Base, Al., 1/2", Universal Mount

$
$

3.76
8.40

$
$

135.49
302.40

Splicer, Alum, Parallel Crimp, Cable


Splice, Alum, Tee Crimp, Cable
Splice, Bimetallic, Parallel, 1-1/2" Contact
Splicer, Cu, Parallel Crimp, Cable
Splicer, Cu, Tee Crimp, Cable
Splicer, Cu, Parallel, 2" Contact

$
$
$
$
$
$

1.58
4.00
6.50
5.62
2.53
14.00

$
$
$

31.50
16.00
39.00

28.00

BOLT,HEX HEAD,1/4-20 X 3/
NUT,HEX,1/4-20,18-8SSTL
Bonding Plate, Alum, 8" sq Contact

$
$
$

0.32
0.04
6.27

$
$

#VALUE!
1.94
0.24

Pipe Bond, Alum, 0.75" - 1.315" O.D


Pipe Bond, Alum, 2" - 2.75" O.D
Pipe Bond, Alum, 2.75" - 3.625" O.D
Pipe Bond, Alum, 4" - 4.5" O.D
Pipe Bond, Alum, 4.5" - 6.5" O.D
Pipe Bond, Alum, 6.625" - 8.625" O.D
Pipe Bond, Alum, 8.625" - 10.750" O.D
Pipe Bond, Cu, 0.75" - 1.315 O.D
Pipe Bond, Cu, 2" - 2-3/4" O.D
Pipe Bond, Cu, 2-3/4" - 3-5/8" O.D
Pipe Bond, Cu, 4" - 4-1/2" O.D
Pipe Bond, Alum, 4.5" - 6.5" O.D
Pipe Bond, Cu, 6.625" - 8.625" O.D
Pipe Bond, Cu, 8.625" - 10.750" O.D

$
13.41
$
21.00
$
24.15
$
27.30
$
38.00
$
31.00 pipe
Size and quantity of required
$
35.70
bonds, associated cable, and splicers
$
20.47
shall be determined by others.
$
26.45
$
29.56
36.57
$
$
38.00
$
65.52
$
73.71

5/8" X10' Copper Bonded Ground Rod 10 Mil


MOLD,CABLE TO GRD ROD,VERT TEE HORZ THRU
CADWELD PLUS Grounding Welding Material - Type F20
MOLD,CABLE TO GRD ROD,VERT X HORZ THRU
CADWELD PLUS Grounding Welding Material - Type F20
IMPROVED DESIGN - CADWELD PLUS Control Unit
5 foot Driver Rod Driver with insert for 5/8" Ground Rods
CADWELD Mold Sealer
Tool Box (included in Complete Tool Kit T315A)

$
$
$
$
$
$
$
$
$

20.45
121.74
10.64
340.94
13.32
174.78
246.07
21.80
53.30

$
$
$
$
$
$
$
$
$

122.70
121.74
10.64
340.94
13.32
174.78
246.07
21.80
53.30

Note: Installer shall be responsible for verifying all products and quantities prior to placing
order to ensure a complete lightning protection system as required
for code compliance.
List Price for Materials Only

#VALUE!

Unless otherwise specified above, the following items ARE NOT INCLUDED in the lot materials price but are
necessary to provide a complete lightning protection system per standards and specifications.
1
2

3
4
5
6
7
8
9
10
11
12
13

Surge protectors, required on certified lightning protection systems per UL, NFPA, and LPI standards on electrical,
telephone, data, cable TV, and other such service line entrances.
For projects requiring UL Master Label Certification, a UL 96A compliant surge protection device must be installed
at the main service entrance panel. This SPD must comply with UL 96A, UL 1449 Ed. 3, and must have the
appropriate UL markings in order to receive the UL Master Label Certification. Devices that meet UL 1449 Ed. 3
alone do not satisfy the new 2011 UL requirements for UL Master Label Certification. The device must meet both
UL 1449 Ed. 3 and UL 96A.
Our bid includes lightning protection materials for roof circuits and wall downleads only. Below grade grounding
systems for all buildings and structures are not included and must be furnished by others.
1" PVC conduit, fastened and installed as raceway for routing exposed or concealed downlead cables.
Trenching and backfilling for below grade routing of counterpoise ground loop cable at 18" minimum depth.
Bond to underground metal piping systems entering buildings as required by UL, NFPA, and LPI standards on
water, gas, storm, sanitary, conduit, and other such pipes.
Special systems grounding of electrical system bonds to building steel, signal reference grounds, bus bars,
electrical service entrance grounding, transformer grounding, telephone system grounding, etc.
Bonding of interior or exterior doors, windows, and louvers.
Bonding of interior or exterior electrical or mechanical equipment, etc.
Grounding resistance tests and ground rod test wells.
Labor estimates and materials for cutting and patching paved or landscaped areas for process of installing lightning
protection system grounding.
Compliance to NEC 250-46. Contractor is responsible for maintaining a 6'-0" distance from lightning protection
system conductor to all conductive metal components.
Lightning protection materials for any other buildings, additions, and structures, new or existing.

ERICO
ERICO, Inc.
34600 Solon Rd.
Solon, OH 44139
USA

Contact:
Phone:
Fax
E-mail:

2/18/2013

Bid Date:

Steve Heine
440-528-3752
440-848-8592
sheine@erico.com

To:

LIGHTNING PROTECTION MATERIALS QUOTATION


System Design Type
Exposed
Semi-Concealed
Concealed

Conductor Type
Roof
Cable
Structural Steel

Materials
Material Type
Copper
Aluminum

Downleads
Cable
Structural Steel

Component Type
Stamped
Cast

Roof Type
Flat
Standing Seam

Grounding
Mechanical
CADWELD

Standards Requirements
NFPA 780
UL 96, 96A
LPI 175, 176

Design Criteria
L.P. Spec. Section:
Drawings:
Addendum Reviewed:

Documents to be provided
Upon receipt of order
Submittal
Drawings
Catalog Data

Terms/Conditions
Note: Freight allowed is $1,500.00 net
Net 30 Days
Add Sales Tax
30 Days Acceptance from:

Following installation
UL Master Label*
UL Letter of Findings
UL Reconditioned Master Label
LPI Certification**
LPI Conditional Certification
* Add
** Add

Note:

Building
Class I
Class II
Air Terminal Size
12 in.
24 in.
Ground Loop
Class I/II
4/0

1) Ground Rods are packaged and sold in


bundles of five only.
2) CADWELD weld metal sold in standard
packages only.

for UL Certification
for LPI Certification

ERICO, Inc. Reserves the right to charge for design drawings.


See Attached Bill(s) of Materials, Excluded Items, and Comments

Contact Person:
CC MM: Chuck Cooley
Steve Heine
CC CSR: Nancy Brown
CADDY CADWELD ERITECH FLEXIBAR LENTON

ERICO
22 Plex Office

Re:

Height of Building
Perimeter of Building

Contact: Steve Heine


Job No: GA-132991
25 ft.
606 ft.

LIGHTNING PROTECTION MATERIALS LINEAR FOOT QUOTATION


Description

Qty
*
*
*
*

775
450
7
7
7
1

Total

Feet of Perimeter Cable (Includes air terminals, bases, conductor, and holders)
Feet of Cross Run Cable (Includes air terminals, bases, conductor, and holders)
Secondary Bonds
Downleads to Grade
18 Feet
Grounding Locations
CADWELD Materials (Includes, molds, shots, and igniter)

10

10

775
450
70
126
70

$1,253.44
$570.21
$87.24
$507.79
$481.58
$368.52

List Price for Materials Only


List Price for UL96A Compliant Surge Protection Device * See Note 2
Price for UL Master Label Certification

$3,922.80
$850.00
$1,400.00

Total Price

$6,172.80

Installation time in man hours (Inexperienced Installer)


Installation time in man hours (Experienced Installer)
1267 Roof Cable
48 Air Terminals/Bases
Thru-Roof Penetrations

126 Downlead Cable


445 Cable Holders/Clips
70 PVC

67
41

14
7

Ground Loop Cable


Miscellaneous Fittings
Ground Rods/Clamps

Unless otherwise specified above, the following items ARE NOT INCLUDED in the lot materials price but are
necessary to provide a complete lightning protection system per standards and specifications.
1
2

3
4
5
6
7
8
9
10
11
12
13

Surge protectors, required on certified lightning protection systems per UL, NFPA, and LPI standards on
electrical, telephone, data, cable TV, and other such service line entrances.
For projects requiring UL Master Label Certification: As of 12/03/2012, UL no longer requires the
inspection of surge protection devices at the main service entrance, but that omission will be noted on
the certificate. ERICO still recommends a UL 96A and UL 1449 Ed. 3 compliant device, and has
included it in this quotation.
Our bid includes lightning protection materials for roof circuits and wall downleads only. Below grade
grounding systems for all buildings and structures are not included and must be furnished by others.
1" PVC conduit, fastened and installed as raceway for routing exposed or concealed downlead cables.
Trenching and backfilling for below grade routing of counterpoise ground loop cable at 18" minimum depth.
Bond to underground metal piping systems entering buildings as required by UL, NFPA, and LPI standards on
water, gas, storm, sanitary, conduit, and other such pipes.
Special systems grounding of electrical system bonds to building steel, signal reference grounds, bus bars,
electrical service entrance grounding, transformer grounding, telephone system grounding, etc.
Bonding of interior or exterior doors, windows, and louvers.
Bonding of interior or exterior electrical or mechanical equipment, etc.
Grounding resistance tests and ground rod test wells.
Labor estimates and materials for cutting and patching paved or landscaped areas for process of installing
lightning protection system grounding.
Compliance to NEC 250-46. Contractor is responsible for maintaining a 6'-0" distance from lightning
protection system conductor to all conductive metal components.
Lightning protection materials for any other buildings, additions, and structures, new or existing.

Underwriters Laboratories

333 PFINGSTEN ROAD, NORTHBROOK, ILLINOIS 60062

Certificate Number
735B-15F9DD

Inspection Date
05/30/2013

Lightning Protection Services

Expiration Date
05/30/2018

MASTER LABEL
CERTIFICATE OF INSPECTION
For
LIGHTNING PROTECTION SYSTEMS
This certificate reports the findings of an inspection by Underwriters Laboratories of a lightning protection
system. The inspection was conducted using all applicable sections of UL 96A, Installation Requirements
for Lightning Protection Systems, Twelfth edition, issued on 10/04/2010. The system was found to comply
with these requirements at the time of inspection.
The following item(s) were omitted from the scope of the Inspection:
Communication surge protection system was not inspected. Surge protection devices are an integral
component of a complete lightning protection system and should be provided on all incoming and exiting
electric, power, data, and communication services.
Structure:
Address:

Installing Company:
Address:

BAPTIST MEDICAL OFFICE BUILDING CLAY COUNTY (EXCLUDING INCONNECTING WALKWAY)


1747 BAPTIST CLAY DRIVE
FLEMING ISLAND, FL 32003
UNITED STATES
ERICO INC
34600 SOLON RD
SOLON, OH 44139

This certificate is only valid for five years based on UL's reasonable estimate that the system will remain
unchanged. Any modifications to electrical, mechanical or communication systems of the structure will
affect lightning protection devices and may render protection afforded by this system ineffective. These
changes will invalidate our certificate earlier than the five year period.

UL and the UL logo are trademarks of UL LLC 2012


Unauthorized reproduction or alteration of this certificate constitutes fraud.

This certificate is for reference use only. To verify Master Label Certificate, please refer to website:
https://lps.ul.com