Unit Overview
Model
Number

Voltage

Design
Cooling
Capacity

V/Hz/Phase

AHRI 210 Standard Efficiency


EER
SEER

ASHRAE 90.1

Btu/hr

DPS003A

208/60/3

36113

13.5

2013
Compliant

16.9

Unit
Model Number:
Model Type:
Heat Type:
Application:
Outside Air:
Altitude:
Approval

DPS003A
Cooling
None
Variable Air Volume, Single Zone
100% Outside Air
0 ft
cETLus

Physical
Dimensions and Weight
Length

Height

67.0

40.8

in

Width

87.0

in

Weight

in

1186

lb

375

lb

Corner Weights
L1

192

L2

209

lb

L3

409

lb

L4
lb

Construction
Exterior

Insulation and Liners

Painted Galvanized
Steel

Air Opening Location

1" Injected Foam, R-7,


Galvanized Steel Liner

Return

Supply

None

Bottom

Electrical
MCA

13.6

MROPD

20

SCCR

5 kAIC

Return/Outside/Exhaust Air
Outside Air Option
Type

Damper Pressure Drop

None

0.03

Exhaust Air Type

None

inHO

Filter Section
Physical
Type

Quantity / Size

Combo 2"/4" rack


with 2" MERV 8

4 / 16 in x 16 in x 2
in

Face Area

7.1

ft

Page 1 of 3

Face Velocity

112.7

ft/min

Air Pressure Drop

0.02
www.DaikinApplied.com

Rebel Packaged Rooftop


System
DX Cooling Coil
Physical
Coil Type

Fins per Inch

Rows

Cu Tube/ Al
Fin

16

Capacity
Total
Sensible
Btu/hr
Btu/hr

Refrigerant
Type

Face Area

4.8

Face Velocity

165.6

ft

Air Pressure
drop

0.11

ft/min

Drain Pan
Material

Stainless
Steel

inHO

Cooling Performance

36113

27362

Indoor Air Temperature


Entering
Leaving
Dry Bulb
Wet Bulb
Dry Bulb
Wet Bulb
F
F
F
F

R410A

80.6

65.0

49.3

Ambient Air
Temperatur
e
F

49.3

80.6

Fan Section
Fan
Type

Fan Wheel Diameter

SWSI AF

12

Fan Isolation

None

in

Performance
Airflow

800

Total Static Pressure

3.5

CFM

Fan Speed

2576

inHO

Brake Horsepower

0.91

rpm

Altitude

HP

Motor

ft

Drive

Type

Horsepower

Efficiency

FLA

Type

ECM Motor

1.3

Premium

3.1 A

Direct Drive

Total Power

Capacity Control

Compressor Isolation

1.6 kW

Mod Control with


Inverter
Compressors

Rubber in Shear

Condensing Section
Compressor
Type

Quantity

Inverter Scroll

Compressor Amps:

Compressor 1

7.7

Condenser Coil
Type

Fins per Inch

Fin Material

Aluminum Microchannel

19

Aluminum

Condenser Fan Motors


Number of Motors

Full Load Current

0.9

AHRI 210 Certified Data at AHRI 210 Standard Conditions


Net Capacity

35500

Btu/hr

EER
13.5

SEER
16.9

ASHRAE 90.1

2013 Compliant

Internal Pressure Drop Calculation


3.00
0.02
0.35
0.03
0.11
3.51

External Static Pressure:


Filter:
Dirty Filter:
Outside Air:
DX Coil:
Total Static Pressure:

Page 2 of 3

inHO
inHO
inHO
inHO
inHO
inHO

www.DaikinApplied.com

Rebel Packaged Rooftop


System
Sound
Sound Power (db)
Frequency
Inlet
Discharge
Radiated

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

71
71
82

69
72
82

75
78
78

73
78
75

76
82
73

75
81
68

71
79
61

66
74
54

Options
Electrical
Field Connection:
Power Options:

Power Block
Phase Failure Monitor

Warranty
Parts:
Compressor:

Standard One Year


Standard One Year

AHRI Certification
All equipment is rated and certified in accordance with AHRI 360.
Notes

Page 3 of 3

www.DaikinApplied.com