Calculation Cover Sheet

Project title
Melut Basin Oil Development Package A
Client
Petrodar Operating Company Limited
Calculation title
Utility Line Sizing
Calculation objective
To determine utility line sizes for Al-Jabalayn CPF plant.

Calc no
(CPF)-CA-PRO-010
Proj no
4211095
Phase/CTR
Detailed
Page
1 of
26

Calculation method
The lines were sized based on the criteria presented in Ranhill Worley Design Standard - Line Sizing
(086\00589-PR-DS-003) with respect to velocity and pressure drop through the line.
The fluid velocity and pressure drop were calculated for a given line size according to the Standard Line
Sizing Spreadsheets (References 1,2).

Assumptions
Refer to Reference 3 for sizing criteria.

References
1. Standard Calculation PR-CA-002 - Single Phase Pressure Drop
2. Standard Calculation PR-CA-001 - Two Phase Pressure Drop
3. Ranhill Worley Design Standard - Line Sizing (086\00589-PR-DS-003)

Conclusions
Refer to the attached summary of selected line sizes.

6-Sep-04

Issued for Review

MYK

REV

DATE

DESCRIPTION

BY

293701913.xls Cover

CHECKED

11/05/2015 Cover

Calculation Checklist
Calc no (CPF)-CA-PRO-010
Project title
Melut Basin Oil Development Package A
Proj no
4211095
Client
Petrodar Operating Company Limited
Phase/CTR
Detailed
Calculation title Utility Line Sizing
Page
2 of
26
Please check boxes for all applicable items checked or delete if not appropriate:
Calculations:
Calculation number assigned and registered (usual format is Proj No-CAL-Discipline code-Seq No eg
XXXX-CAL-E-001, but format may be varied by Project Manager).
Project title shown.
Calculation title shown.
Revision history box complete and signed.
Index.
Appropriate stamp for preliminary issues.
Calculation objectives (aims) stated.
Calculation method defined or described (including formulae if relevant).
Reference made to text, standard or code. Check version/edition with that required for project.
Source of input data stated (with revision number and date if relevant).
Assumptions stated.
Summary of results or conclusions if appropriate.
For software based calculations, reference to software verification if available.
Method clear and easy to follow.
Input data correct.
Calculation arithmetically correct OR software previously verified and reference to verification
checked.
Calculation result within expected limits.
Calculation tolerances stated if significant.
Units used as required by client.
Abbreviations correct.
Appropriate cross-references.
Sketches included and clearly labelled, where required.
Attachments included and referenced, as required.
Checking records:
Checked and annotated copy of calculation filed (use "Check Print" stamp).
Corrections made as required and calculation dated and signed on cover sheet by checker.
Revisions:
Changes clouded.
Revision history block updated.
Calculation re-checked if required.

6-Sep-04

Issued for Review

MYK

REV

DATE

DESCRIPTION

BY

293701913.xls Checklist

CHECKED

11/05/2015 Checklist

Calculation Sheet
Project title
Client
Calculation title
Activity
PFD
Stream
No.

Calc no
(CPF)-CA-PRO-010
Proj no
4211095
Phase/CTR
Detailed
Page
3 of
26
File

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing
Line Sizing Summary

Design
Design Pressure
Velocity Drop [kPa/100m]
[m/s]

Velocity
[m/s]

Pressure
Drop
[kPa/100m]

150#

2.5

82.0

2 to 3

90.0

20

150#

3.0

34.1

2 to 3

90.0

100

40

150#

0.3

1.9

1.5

5 - 14

Liquid

100

40

150#

0.3

1.0

3.0

23 - 35

1) Slop oil pumps (P-5403A/B) discharge


lines

Liquid

80

40

150#

0.6

5.7

1.5

5 - 14

1) Slop oil pumps (P-5403A/B) discharge


lines

Liquid

80

40

150#

0.6

4.1

3.0

23 - 35

Liquid

150

40

150#

0.2

1.7

1.5

5 - 14

2) Fuel oil pumps (P-5405A/B) discharge


lines

Liquid

150

40

150#

0.5

8.9

3.0

23 - 35

11,122

1) Fuel oil to heat medium skid

Liquid

80

40

150#

0.7

22.8

2-3

90.0

2"-CO-AC-1262-25H-ET

1,668

2) Crude oil from PSVs on inlet manifold

Liquid

80

40

150#

0.2

16.6

2-3

90.0

Fuel Oil 3

2"-CO-AC-1263-25H-ET

4,449

Fuel Oil to Pump Station #2

Liquid

50

40

150#

0.6

44.7

2-3

90.0

Blowdown 1

4"-CO-CC-1255-25H-ET

69,225

1) Crude oil from Yo-Yo pump to blowdown

Liquid

80

600#

2.8

###

2-3

90.0

Blowdown 1

16"-PR-AC-6001-38H-ET

2,034,989

2) Crude oil from PSVs on inlet manifold

Liquid

20

150#

5.1

###

2-3

90.0

Blowdown 2

10"-CO-AC-1246-25H-ET

55,380

1) Blowdown tank pumps (P-5406A/B)


suction lines

Liquid

20

150#

0.3

10.1

1.8

11 - 23

Blowdown 2

4"-CO-AC-1253, 1254-25H-ET

27,690

2) Blowdown tank pumps (P-5406A/B)


discharge lines

Liquid

40

150#

0.4

42.5

3.0

23 to 35

Blowdown 3

6"-CO-AC-1252-25H-ET

27,690

1) Blowdown tank pumps (P-5406A/B)


discharge lines

Liquid

40

150#

0.4

42.5

2.5

23 - 35

Blowdown 3

12"-CO-AC-1256-38H-ET

69,225

2) Yo Yo operation pump (P-5407) suction


lines

Liquid

20

150#

0.3

5.9

1.8

11 - 23

Blowdown 4

4"-CO-CC-1257-25H-ET

69,225

1) Yo Yo operation pump (P-5407)


discharge line

Liquid

80

600#

2.8

###

2.5

23 - 35

Blowdown 4

4"-CO-AC-1250,1251-25H-ET

27,690

2) Blowdown tank pumps (P-5406A/B)


suction lines

Liquid

40

150#

1.0

###

1.4

5 - 14

Diesel 1

3"-FO-A-4010

24,900

1)Diesel unloading pump (P-5445) suction


line

Liquid

40

150#

1.7

43.2

1.0

5 - 14

Diesel 1

3"-FO-A-4010

24,900

Liquid

40

150#

1.0

11.6

1.0

5 - 14

Diesel 2

3"-FO-A-4012, 4013

24,900

Liquid

40

150#

1.7

43.2

1.8

23 - 35

Diesel 2

4"-FO-A-4012, 4013

24,900

Liquid

40

150#

1.0

11.6

1.8

23 - 35

Diesel 3

3"-FO-A-4014, 4015

10,790

1) Diesel transfer pumps (P-5446A/B)


suction line

Liquid

80

40

150#

0.8

9.8

1.0

5 - 14

Diesel 3

3"-FO-A-4016, 4017, 4022

10,790

2) Diesel transfer pumps (P-5446A/B)


discharge line

Liquid

80

40

150#

0.8

9.8

1.8

23 - 35

Diesel 4

3"-FO-A-4022

10,790

1) Diesel transfer pumps (P-5446A/B)


discharge line (P&ID: JAB-CPF1-PID2167-1 Rev. 1)

Liquid

80

40

150#

0.8

9.8

2-3

90.0

Diesel 4

1"-FO-A-4036, 4023

830

2) Diesel to booster pump day tank and to


fire water

Liquid

80

40

150#

0.5

11.6

2-3

90.0

Diesel 5

2"-FO-A-4021

10,790

1) Diesel to heat medium heaters

Liquid

50

40

150#

1.7

65.7

2-3

90.0

Diesel 5

2"-FO-A-4024

830

2) Diesel to emergency generator

Liquid

50

40

150#

0.1

0.7

2-3

90.0

Line No.

Design Flow
Rate (kg/h)

Slop Oil (1)

4"-CO-AC-1109 to 1117-25H-ET

65,070

Slop Oil (1)

10"-CO-AC-1124-25H-ET

Slop Oil (2)

Phase

PWH

SCH

Rating

1) Interface draw-off from the Electrostatic

Liquid

100

40

498,870

2) Common header for Interface draw-off

Liquid

100

4"-CO-AC-1182-25H-ET

8,676

1) Slop oil pumps (P-5403A/B) suction


lines

Liquid

Slop Oil (2)

4"-CO-AC-1183-25H-ET

9,438

1) Slop oil pumps (P-5403A/B) suction


lines

Slop Oil (3)

3"-CO-AC-1185-25H-ET

8,676

Slop Oil (3)

3"-CO-AC-1060-25H-ET

9,438

Fuel Oil 1

6"-CO-AC-1239, 1240-25H-ET

12,902

Fuel Oil 1

4"-CO-AC-1217, 1218-25H-ET

12,902

Fuel Oil 2

3"-CO-AC-1218-25H-ET

Fuel Oil 2

293701913.xls Summary

Description

1) Fuel oil pumps (P-5405A/B) suction lines

1)Diesel unloading pump (P-5445)


discharge line

11/05/2015 Summary

Diesel 6

2"-FO-A-4025

8,928

1) Diesel to heat medium heaters

Liquid

50

40

150#

1.4

46.9

2-3

90.0

Diesel 6

2"-FO-A-4065

11,620

2) Diesel to PS#2

Liquid

50

40

150#

1.8

74.9

2-3

90.0

Open Drain1

3"-PW-AC-2033/34/35/36

4,500

Open Drain Sump Pump Discharge

Liquid

80

40

150#

0.3

1.3

1.0

5 - 14

Open Drain1

3"-PW-AC-2020/37

4,500

Open Drain Sump Pump Discharge

Liquid

80

40

150#

0.3

1.3

1.8

23 - 35

Open Drain2

3"-PW-AC-2021/38

9,000

Open Drain Sump Pump Common


Discharge

Liquid

80

40

150#

0.6

4.5

1.8

23 - 35

Open Drain2

3"-CO-AC-1233/34/35/36

13,500

Closed Drain Pump Discharge

Liquid

80

40

150#

0.9

9.5

1.0

5 - 14

Open Drain3

4"-CO-AC-1238/48-25H-ET

27,000

Closed Drain Pump Common Discharge

Liquid

100

40

150#

1.0

9.0

2.5

23 - 35

Treated
Water2

6"-UW-A-4157/58

42,000

1. Water from Treatment package to


Storage Tanks

Liquid

150

40

150#

0.6

2.4

1.5

5 - 14

Treated
Water2

6"-UW-A-4157/58

42,000

2. Water from Tanks to further treatment

Liquid

150

40

150#

0.6

2.4

1.5

5 - 14

Treated
Water3

3"-UW-A-4029/30

21,000

1. Treated Water to Users

Liquid

80

40

150#

1.2

19.6

1.8

23 - 35

Treated
Water3

2"-UW-A-4166/68

8,400

2. Potable Water to users

Liquid

50

40

150#

1.1

25.2

1.8

23 - 35

Treated
Water4

3"-UW-A-4029/30

37,800

Treated Water to Users

Liquid

80

150#

2.5

79.8

0.6 to 4.8

6 to 45

Treated
Water5

8"-SW-A-4501

85,200

1. White Nile River Water Lift Pumps, P5468A/B discharge line.

Liquid

150

40

150#

1.8 to 4.3

35 to 45

293701913.xls Summary

1.1

7.9

11/05/2015 Summary

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
4 of
26

Note: You c
worksheet
Copy Work

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99
(1)

(2)

INPUT
Line Number

4"-CO-AC-1109 to 1117-25H-ET

10"-CO-AC-1124-25H-ET

Mass & Energy Balance Stream No.

PROCESS DATA

1) Interface draw-off from the Electrostatic

Liquid
Liquid

Liquid
Liquid

[C]

105.0

105.0

[kPaa]

101.33

101.33

[kg/h]

65,070

498,870

0%

0%

[kg/h]

65,070

498,870

2) Common header for Interface draw-off

[kg/m]

867.60

867.60

from the Elec. Dehydrator to Slop Tank

[cP]

18.000

18.000

Flowrate :

[mm]

100

250

Properties:

AC
AC

AC
AC

Phase
Temperature, T
Pressure, P
Mass Flowrate
Design Margin
Design Flow
Actual Density
Actual Viscosity

(P&ID: JAB-CPF1-PID-2136-1 Rev. 1)

Dehydrator to Slop Tank


Flowrate :

Properties:

LINE SPECIFICATION
Nominal Diameter
Piping Specification
ANSI Rating

150#

Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

150#

4040

2020

102.3

260.4

CS

CS

PIPE ID

CS

0.046

0.046

0.00821

0.05326

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

2.54

3.00

12,500

37,640

0.030

0.023

[kPa/100m]

82.01

34.13

[m/s]

2 to 3

2 to 3

Vapour Criteria

[kPa/100m]

90.0

90.0

Liquid Criteria

CONCLUSIONS
Therefore the recommended line size for 4"-CO-AC-1109 to 1117-25H-ET is

100

mm NB

Therefore the recommended line size for 10"-CO-AC-1124-25H-ET is

250

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

293701913.xls Slop Oil (1)

11/05/2015 Slop Oil (1)

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
5 of
26

Note: You c
worksheet
Copy Work

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99

INPUT
Line Number

4"-CO-AC-1182-25H-ET

4"-CO-AC-1183-25H-ET

Mass & Energy Balance Stream No.

PROCESS DATA

1) Slop oil pumps (P-5403A/B) suction lines

Liquid
Liquid

Liquid
Liquid

[C]

105.0

105.0

[kPaa]

101.33

101.33

[kg/h]

8,676

9,438

0%

0%

[kg/h]

8,676

9,438

[kg/m]

867.60

943.80

[cP]

18.000

0.265

[mm]

100

100

AC
AC

AC
AC

Phase
Temperature, T
Pressure, P
Mass Flowrate
Design Margin
Design Flow
Actual Density
Actual Viscosity

(P&ID: JAB-CPF1-PID-2136-1 Rev. 1)

Flowrate : Slop oil pumps capacity

Properties: From slop oil pumps datasheet

LINE SPECIFICATION
Nominal Diameter
Piping Specification
ANSI Rating

150#

Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

150#

4040

4040

102.3

102.3

CS

CS

PIPE ID

CS

0.046

0.046

0.00821

0.00821

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

0.34

0.34

1,670

123,180

0.038

0.020

[kPa/100m]

1.86

1.04

[m/s]

1.5

3.0

Vapour Criteria

5 - 14

23 - 35

Liquid Criteria

[kPa/100m]

CONCLUSIONS
Therefore the recommended line size for 4"-CO-AC-1182-25H-ET is

100

mm NB

Therefore the recommended line size for 4"-CO-AC-1183-25H-ET is

100

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

293701913.xls Slop Oil (2)

11/05/2015 Slop Oil (2)

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
6 of
26

Note: You c
worksheet
Copy Work

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99

INPUT
Line Number

3"-CO-AC-1185-25H-ET

3"-CO-AC-1060-25H-ET

Mass & Energy Balance Stream No.

PROCESS DATA

1) Slop oil pumps (P-5403A/B) discharge lines

Liquid
Liquid

Liquid
Liquid

[C]

105.0

105.0

[kPaa]

851.33

101.33

[kg/h]

8,676

9,438

0%

0%

[kg/h]

8,676

9,438

[kg/m]

867.60

943.80

[cP]

18.000

0.265

[mm]

80

80

AC
AC

AC
AC

Phase
Temperature, T
Pressure, P
Mass Flowrate
Design Margin
Design Flow
Actual Density
Actual Viscosity

(P&ID: JAB-CPF1-PID-2136-1 Rev. 1)

Flowrate : Slop oil pumps capacity

Properties: From slop oil pumps datasheet

LINE SPECIFICATION
Nominal Diameter
Piping Specification
ANSI Rating

150#

Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

150#

4040

Pipe Schedule

4040

77.9

CS
[mm]

CS

PIPE ID

77.9

CS

CS

0.046

0.046

0.00477

0.00477

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

0.58

0.58

2,190

161,660

0.030

0.020

[kPa/100m]

5.69

4.06

[m/s]

1.5

3.0

Vapour Criteria

5 - 14

23 - 35

Liquid Criteria

[kPa/100m]

CONCLUSIONS
Therefore the recommended line size for 3"-CO-AC-1185-25H-ET is

80

mm NB

Therefore the recommended line size for 3"-CO-AC-1060-25H-ET is

80

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

293701913.xls Slop Oil (3)

11/05/2015 Slop Oil (3)

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
7 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99
(1)

(2)

INPUT
Line Number

6"-CO-AC-1239, 1240-25H-ET

4"-CO-AC-1217, 1218-25H-ET

Mass & Energy Balance Stream No.

(P&ID: JAB-CPF1-PID-2138-1 Rev. 1)

PROCESS DATA

1) Fuel oil pumps (P-5405A/B) suction lines

Liquid
Liquid

Liquid
Liquid

75.0

75.0

[kPaa]

101.30

604.10

[kg/h]

12,902

12,902

0%

0%

[kg/h]

12,902

12,902

2) Fuel oil pumps (P-5405A/B) discharge lines

[kg/m]

889.76

889.76

Flowrate : Fuel oil pumps (P-5405A/B) cap.

[cP]

59.675

59.675

[mm]

150

100

Piping Specification

AC
AC

A
A

ANSI Rating

150#

150#

40
40

40
40

154.1

102.3

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density
Actual Viscosity
LINE SPECIFICATION
Nominal Diameter

Properties: From fuel oil pumps datasheet

Properties: From fuel oil pumps datasheet

Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

Flowrate : Fuel oil pumps (P-5405A/B) cap.

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

[m]

0.01865

0.00821

[m/s]

0.22

0.49

500

750

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity
Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

0.128

0.085

[kPa/100m]

1.72

8.93

[m/s]

1.5

3.0

Vapour Criteria

5 - 14

23 - 35

Liquid Criteria

[kPa/100m]

CONCLUSIONS
Therefore the recommended line size for 6"-CO-AC-1239, 1240-25H-ET is

150

mm NB

Therefore the recommended line size for 4"-CO-AC-1217, 1218-25H-ET is

100

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

293701913.xls Fuel Oil 1

11/05/2015 Fuel Oil 1

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
8 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99
(1)

(2)

INPUT
Line Number

3"-CO-AC-1218-25H-ET

2"-CO-AC-1262-25H-ET

Mass & Energy Balance Stream No.

(P&ID: JAB-CPF1-PID-2138-1 Rev. 1)

PROCESS DATA

1) Fuel oil to heat medium skid

Liquid
Liquid

Liquid
Liquid

75.0

75.0

[kPaa]

604.10

604.10

[kg/h]

11,122

1,668

0%

0%

[kg/h]

11,122

1,668

2) Fuel oil to power plant

[kg/m]

889.76

889.76

Flowrate : Info from OGP

[cP]

59.675

59.675

[mm]

80

50

Piping Specification

AC
AC

A
A

ANSI Rating

150#

150#

40
40

40
40

77.9

52.5

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density
Actual Viscosity
LINE SPECIFICATION
Nominal Diameter

Properties: From fuel oil pumps datasheet

Properties: From fuel oil pumps datasheet

Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

Flowrate : From hot oil vendor's datasheet.

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

[m]

0.00477

0.00216

[m/s]

0.73

0.24

850

190

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity
Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

0.075

0.337

[kPa/100m]

22.79

16.55

[m/s]

2-3

2-3

Vapour Criteria

[kPa/100m]

90.0

90.0

Liquid Criteria

CONCLUSIONS
Therefore the recommended line size for 2"-CO-AC-1218-25H-ET is
Therefore the recommended line size for 2"-CO-AC-1240-25H-ET is

now

80

mm NB

50

mm NB

Revised from 2 ro 3" due to higher flow

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

293701913.xls Fuel Oil 2

11/05/2015 Fuel Oil 2

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
9 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99

INPUT
Line Number

2"-CO-AC-1263-25H-ET

Mass & Energy Balance Stream No.

PROCESS DATA

Liquid
Liquid

Liquid
Liquid

75.0

75.0

[kPaa]

604.10

604.10

[kg/h]

4,449

0%

0%

[kg/h]

4,449

[kg/m]

889.76

889.76

[cP]

59.675

59.675

[mm]

50

25

Piping Specification

AC
AC

1P
1P

ANSI Rating

150#

150#

40
40

STD
STD

52.5

26.6

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density
Actual Viscosity
LINE SPECIFICATION
Nominal Diameter

Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

[m]

0.00216

0.00056

[m/s]

0.64

0.00

500

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity
Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

0.128

#DIV/0!

[kPa/100m]

44.73

#DIV/0!

[m/s]

2-3

Vapour Criteria

[kPa/100m]

90.0

Liquid Criteria

CONCLUSIONS
Therefore the recommended line size for 2"-CO-AC-1241-25H-ET is

50

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
10 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99
(1)

(2)

INPUT
Line Number

4"-CO-CC-1255-25H-ET

16"-PR-AC-6001-38H-ET

Mass & Energy Balance Stream No.

PROCESS DATA

1) Crude oil from Yo-Yo pump to blowdown

Liquid
Liquid

Liquid
Liquid

45.0

45.0

[kPaa]

881.30

1481.30

[kg/h]

69,225

2,034,989

0%

0%

69,225

2,034,989

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density

[kg/h]
[kg/m]

923.00

923.00

[cP]

669.088

669.088

[mm]

100

400

Piping Specification

CC
CC

AC
AC

ANSI Rating

600#

150#

80
80

20
20

97.2

390.6

Actual Viscosity
LINE SPECIFICATION
Nominal Diameter

tank
Flowrate : From Yo-Yo operation pump cap.

Properties: From crude oil on the header

2) Crude oil from PSVs on inlet manifold


Flowrate : From PSVs calculation

Properties: From PSVs calculation

Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

(P&ID: JAB-CPF1-PID-2139/40-1 Rev. 1)

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

[m]

0.00742

0.11980

[m/s]

2.81

5.11

380

2,750

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity
Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

0.168

0.041

630.99

125.27

[m/s]

2-3

2-3

Vapour Criteria

[kPa/100m]

90.0

90.0

Liquid Criteria

[kPa/100m]

CONCLUSIONS
Though the pressure drop for 4"-CO-CC-1255-25H-ET is high, the selected line size is
intermittently. Similarly, selected line size for 16"-PR-AC-6001-38H-ET is

400

100

mm NB because the line is used

mm NB even though velocity and pressure drop

are higher than design range due to intermittent service.

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77
file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Blowdown 1

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
11 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99
(1)

(2)

INPUT
Line Number

10"-CO-AC-1246-25H-ET

4"-CO-AC-1253, 1254-25H-ET

Mass & Energy Balance Stream No.

PROCESS DATA

1) Blowdown tank pumps (P-5406A/B) suction lines

Liquid
Liquid

Liquid
Liquid

45.0

45.0

[kPaa]

101.30

881.30

[kg/h]

55,380

27,690

0%

0%

55,380

27,690

2) Blowdown tank pumps (P-5406A/B) discharge lines


Flowrate : Blowdown tank pumps (P-5406A/B) cap.

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density

[kg/h]
[kg/m]

923.00

923.00

[cP]

669.088

669.088

[mm]

250

150

Piping Specification

AC
AC

AC
AC

ANSI Rating

150#

150#

20
20

40
40

260.4

154.1

Actual Viscosity

Flowrate : Blowdown tank pumps (P-5406A/B) cap.

Properties: From blowdown tank pumps datasheet

LINE SPECIFICATION
Nominal Diameter

Properties: From Blowdown tank pumps (P-5406A/B) datasheet

Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

(P&ID: JAB-CPF1-PID-2138-1 Rev. 1)

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

[m]

0.05326

0.01865

[m/s]

0.31

0.45

110

90

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity
Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

[kPa/100m]
[m/s]
[kPa/100m]

0.582

0.711

10.10

42.54

1.8

3.0

Vapour Criteria

11 - 23

23 to 35

Liquid Criteria

CONCLUSIONS
Though the DP for 8"-CO-AC-1246-25H-ET is high, the selected line size is was changed to
The selected line size for 4"-CO-AC-1253, 1254-25H-ET is was changed from 100 to

150

250

mm NB from 200

mm NB

are higher than design range due to intermittent service. To be confirmed upon receipt of vendor data.

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77
file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Blowdown 2

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
12 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99
(1)

(2)

INPUT
Line Number

6"-CO-AC-1252-25H-ET

12"-CO-AC-1256-38H-ET

Mass & Energy Balance Stream No.

(P&ID: JAB-CPF1-PID-2139/40-1 Rev. 1)

PROCESS DATA

1) Blowdown tank pumps (P-5406A/B) discharge lines

Liquid
Liquid

Liquid
Liquid

45.0

45.0

[kPaa]

881.30

101.30

[kg/h]

27,690

69,225

0%

0%

27,690

69,225

2) Yo Yo operation pump (P-5407) suction lines


Flowrate : Yo Yo operation pumps (P-5407) cap.

Phase
Temperature, T

[C]

Pressure, P
Mass Flowrate
Design Margin
Design Flow

[kg/h]

Actual Density

[kg/m]

923.00

923.00

[cP]

669.088

669.088

[mm]

150

300

Piping Specification

AC
AC

AC
AC

ANSI Rating

150#

150#

40
40

20
20

154.1

311.2

Actual Viscosity
LINE SPECIFICATION

Flowrate : Blowdown tank pumps (P-5406A/B) cap.

Properties: From blowdown tank pumps datasheet

Properties: Yo Yo operation pumps datasheet

Nominal Diameter

Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction

CS

Pipe Roughness

[mm]

CS

CS

PIPE ID

CS

0.046

0.046

[m]

0.01865

0.07606

[m/s]

0.45

0.27

90

120

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity
Reynolds Number
Darcy Friction Factor
Pressure Drop

[kPa/100m]

Velocity Design Range


DP Design Range

[m/s]
[kPa/100m]

0.711

0.533

42.54

5.93

2.5

1.8

Vapour Criteria

23 - 35

11 - 23

Liquid Criteria

CONCLUSIONS
Though the DP for 6"-CO-AC-1252-25H-ET is higher than design range, the selected size is

150

mm NB because the line is

used intermittently. To be confirmed upon receipt of vendor data.


Selected size of 8"-CO-AC-1256-38H-ET is

300

mm NB and was increased from a previous value of 8"

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77
file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Blowdown 3

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
13 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99
(1)

(2)

INPUT
Line Number

4"-CO-CC-1257-25H-ET

4"-CO-AC-1250,1251-25H-ET

Mass & Energy Balance Stream No.

PROCESS DATA

1) Yo Yo operation pump (P-5407) discharge line

Liquid
Liquid

Liquid
Liquid

45.0

45.0

[kPaa]

881.30

101.30

[kg/h]

69,225

27,690

0%

0%

69,225

27,690

2) Blowdown tank pumps (P-5406A/B) suction lines


Flowrate : Blowdown tank pumps (P-5406A/B) cap.

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density

[kg/h]
[kg/m]

923.00

923.00

[cP]

669.088

669.088

[mm]

100

100

Piping Specification

CC
CC

AC
AC

ANSI Rating

600#

150#

80
80

40
40

97.2

102.3

Actual Viscosity
LINE SPECIFICATION
Nominal Diameter

Flowrate : Yo Yo operation pump (P-5407) cap.

Properties: Yo Yo operation pump datasheet

Properties: Blowdown tank pumps (P-5406A/B) datasheet

Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

(P&ID: JAB-CPF1-PID-2139/40-1 Rev. 1)

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

[m]

0.00742

0.00821

[m/s]

2.81

1.01

380

140

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity
Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

[kPa/100m]
[m/s]
[kPa/100m]

0.168

0.457

630.99

212.40

2.5

1.4

Vapour Criteria

23 - 35

5 - 14

Liquid Criteria

CONCLUSIONS
Though the velocity and DP for 4"-CO-CC-1257-25H-ET are higher than design range, the selected size is
the line is used intermittently. Similarly, selected line size for 4"-CO-AC-1250, 1251-25H-ET is

100

mm NB because

100 mm NB even though

velocity and DP are higher than design range due to intermittent service. To be confirmed upon receipt of vendor data.

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77
file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Blowdown 4

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
14 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99

INPUT
Line Number

3"-FO-A-4010

3"-FO-A-4010

Mass & Energy Balance Stream No.

PROCESS DATA

1)Diesel unloading pump (P-5445) suction line

Liquid
Liquid

Liquid
Liquid

39.0

39.0

[kPaa]

101.30

101.30

[kg/h]

24,900

24,900

0%

0%

[kg/h]

24,900

24,900

[kg/m]

830.00

830.00

[cP]

5.000

5.000

[mm]

80

100

A
A

A
A

150#

150#

40
40

40
40

77.9

102.3

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density
Actual Viscosity

(P&ID: JAB-CPF1-PID-2166-1 Rev. 1)

Flowrate : Diesel unloading pump (P-5445) cap.

Properties: Diesel unloading pump (P-5445) datasheet

LINE SPECIFICATION
Nominal Diameter
Piping Specification
ANSI Rating
Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

0.00477

0.00821

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

[kPa/100m]
[m/s]
[kPa/100m]

1.75

1.01

22,600

17,220

0.027

0.028

43.18

11.63

1.0

1.0

Vapour Criteria

5 - 14

5 - 14

Liquid Criteria

CONCLUSIONS
Therefore the recommended line size is

100

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Diesel 1

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
15 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99

INPUT
Line Number

3"-FO-A-4012, 4013

4"-FO-A-4012, 4013

Mass & Energy Balance Stream No.

PROCESS DATA

1)Diesel unloading pump (P-5445) discharge line

Liquid
Liquid

Liquid
Liquid

39.0

39.0

[kPaa]

101.30

101.30

[kg/h]

24,900

24,900

0%

0%

[kg/h]

24,900

24,900

[kg/m]

830.00

830.00

[cP]

5.000

5.000

[mm]

80

100

A
A

A
A

150#

150#

40
40

40
40

77.9

102.3

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density
Actual Viscosity

(P&ID: JAB-CPF1-PID-2166-1 Rev. 1)

Flowrate : Diesel unloading pump (P-5445) cap.

Properties: Diesel unloading pump (P-5445) datasheet

LINE SPECIFICATION
Nominal Diameter
Piping Specification
ANSI Rating
Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

0.00477

0.00821

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

[kPa/100m]
[m/s]
[kPa/100m]

1.75

1.01

22,600

17,220

0.027

0.028

43.18

11.63

1.8

1.8

Vapour Criteria

23 - 35

23 - 35

Liquid Criteria

CONCLUSIONS
Since the calculated DP is higher than allowable DP,the line size was increased from 3 to 4"
not used for continuous service. Therefore the recommended line size is

100

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Diesel 2

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
16 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99
(1)

(2)

INPUT
Line Number

3"-FO-A-4014, 4015

3"-FO-A-4016, 4017, 4022

Mass & Energy Balance Stream No.

PROCESS DATA

1) Diesel transfer pumps (P-5446A/B) suction line

Liquid
Liquid

Liquid
Liquid

39.0

39.0

[kPaa]

101.30

601.30

[kg/h]

10,790

10,790

0%

0%

2) Diesel transfer pumps (P-5446A/B) discharge line

[kg/h]

10,790

10,790

Flowrate : Diesel transfer pumps (P-5446A/B) cap.

[kg/m]

830.00

830.00

[cP]

5.000

5.000

[mm]

80

80

A
A

A
A

150#

150#

40
40

40
40

77.9

77.9

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density
Actual Viscosity

(P&ID: JAB-CPF1-PID-2167-1 Rev. 1)

Flowrate : Diesel transfer pumps (P-5446A/B) cap.

Properties: Diesel transfer pumps (P-5446A/B) datasheet

Properties: Diesel transfer pumps (P-5446A/B) datasheet

LINE SPECIFICATION
Nominal Diameter
Piping Specification
ANSI Rating
Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

0.00477

0.00477

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

0.76

0.76

9,800

9,800

0.032

0.032

[kPa/100m]

9.83

9.83

[m/s]

1.0

1.8

Vapour Criteria

5 - 14

23 - 35

Liquid Criteria

[kPa/100m]

CONCLUSIONS
Therefore the recommended line size for 3"-FO-A-4014 and 4015 is

80

mm NB

Therefore the recommended line size for 3"-FO-A-4016, 4017 and 4022 is

80

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Diesel 3

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
17 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99
(1)

(2)

INPUT
Line Number

3"-FO-A-4022

1"-FO-A-4036, 4023

Mass & Energy Balance Stream No.

PROCESS DATA

1) Diesel transfer pumps (P-5446A/B) discharge line

Liquid
Liquid

Liquid
Liquid

39.0

39.0

[kPaa]

551.30

551.30

[kg/h]

10,790

830

0%

0%

2) Diesel to booster pump day tank and to fire water

[kg/h]

10,790

830

pump diesel day tank respectively.

[kg/m]

830.00

830.00

[cP]

5.000

5.000

[mm]

80

25

A
A

A
A

150#

150#

40
40

40
40

77.9

26.6

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density
Actual Viscosity
LINE SPECIFICATION
Nominal Diameter

Flowrate : Diesel transfer pumps (P-5446A/B) cap.

Properties: Diesel transfer pumps (P-5446A/B) datasheet

Flowrate : Diesel transfer pumps (P-5446A/B) cap.

Properties: Diesel transfer pumps (P-5446A/B) datasheet

Piping Specification
ANSI Rating
Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

(P&ID: JAB-CPF1-PID-2167-1 Rev. 1)

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

0.00477

0.00056

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

0.76

0.50

9,800

2,200

0.032

0.030

[kPa/100m]

9.83

11.64

[m/s]

2-3

2-3

Vapour Criteria

[kPa/100m]

90.0

90.0

Liquid Criteria

CONCLUSIONS
Therefore the recommended line size for 3"-FO-A-4022 is

80

mm NB

Therefore the recommended line size for 1"-FO-A-4036, 4023 is

25

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Diesel 4

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
18 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99
(1)

(2)

INPUT
Line Number

2"-FO-A-4021

2"-FO-A-4024

Mass & Energy Balance Stream No.

PROCESS DATA

1) Diesel to diesel storage tank

Liquid
Liquid

Liquid
Liquid

39.0

39.0

[kPaa]

551.30

551.30

[kg/h]

10,790

830

0%

0%

2) Diesel to emergency generator

[kg/h]

10,790

830

Flowrate : Vendor specified

[kg/m]

830.00

830.00

[cP]

5.000

5.000

[mm]

50

50

A
A

A
A

150#

150#

40
40

40
40

52.5

52.5

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density
Actual Viscosity

(P&ID: JAB-CPF1-PID-2167-1 Rev. 1)

Flowrate : Diesel transfer pumps (P-5446A/B) cap.

Properties: Diesel transfer pumps (P-5446A/B) datasheet

Properties: Diesel transfer pumps (P-5446A/B) datasheet

LINE SPECIFICATION
Nominal Diameter
Piping Specification
ANSI Rating
Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

0.00216

0.00216

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

1.67

0.13

14,540

1,120

0.030

0.057

[kPa/100m]

65.67

0.75

[m/s]

2-3

2-3

Vapour Criteria

[kPa/100m]

90.0

90.0

Liquid Criteria

CONCLUSIONS
Therefore the recommended line size for 3"-FO-A-4021 is

50

mm NB

Therefore the recommended line size for 1"-FO-A-4024 is

50

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Diesel 5

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
19 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99
(1)

(2)

INPUT
Line Number

2"-FO-A-4025

2"-FO-A-4065

Mass & Energy Balance Stream No.

PROCESS DATA

1) Diesel to heat medium heaters

Liquid
Liquid

Liquid
Liquid

39.0

39.0

[kPaa]

551.30

551.30

[kg/h]

8,928

11,620

0%

0%

[kg/h]

8,928

11,620

[kg/m]

830.00

830.00

[cP]

5.000

5.000

[mm]

50

50

A
A

A
A

150#

150#

40
40

40
40

52.5

52.5

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density
Actual Viscosity

(P&ID: JAB-CPF1-PID-2167-1 Rev. 1)

Flowrate : Vendor specified.

Properties: Diesel transfer pumps (P-5446A/B) datasheet

2) Diesel to PS#2
Flowrate : Vendor specified

Properties: Diesel transfer pumps (P-5446A/B) datasheet

LINE SPECIFICATION
Nominal Diameter
Piping Specification
ANSI Rating
Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

0.00216

0.00216

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

1.38

1.80

12,030

15,660

0.031

0.029

[kPa/100m]

46.92

74.95

[m/s]

2-3

2-3

Vapour Criteria

[kPa/100m]

90.0

90.0

Liquid Criteria

CONCLUSIONS
Therefore the recommended line size for 3"-FO-A-XXXX is

50

mm NB

Therefore the recommended line size for 1"-FO-A-XXXX is

50

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Diesel 6

PIPE ID FOR WELDED & SEAMLESS STEEL PIPE


OUTSIDE STANDARD EXTRA
XX
SCHEDULE
DIAMETER
STRONG STRONG
DN
mm
25
33.4
26.64
24.3
15.22
50
60.3
52.48
49.22
38.16
80
88.9
77.92
73.66
58.42
100
114.3
102.26
97.18
80.06
150
168.3
154.08
146.36
124.4
200
219.1
202.74
193.7
174.64
250
273.1
254.56
247.7
222.3
300
323.9
304.84
298.5
273.1
350
355.6
336.54
330.2
400
406.4
387.34
381
450
457
437.94
431.6
500
508
488.94
482.6
550
559
539.94
533.6
600
610
590.94
584.6
650
660
640.94
634.6
700
711
691.94
685.6
750
762
742.94
736.6
800
813
793.94
787.6
850
864
844.94
838.6
900
914
894.94
888.6
1050
1067
1047.94
1041.6
-

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

SCH
10

SCH
20

SCH
30

SCH
40

SCH
60

SCH
80

SCH
100

SCH
120

SCH
140

SCH
160

342.9
393.7
444.3
495.3
546.3
597.3
644.16
695.16
746.16
797.16
848.16
898.16
-

206.4
260.4
311.2
339.76
390.56
441.16
488.94
539.94
590.94
634.6
685.6
736.6
787.6
838.6
888.6
-

205.02
257.5
307.14
336.54
387.34
434.74
482.6
533.6
581.46
679.24
730.24
781.24
832.24
882.24
-

26.64
52.48
77.92
102.26
154.08
202.74
254.56
303.28
333.34
381
428.46
477.82
575.04
778.04
829.04
875.9
-

198.48
247.7
295.36
325.42
373.08
418.9
466.76
514.54
560.78
-

24.3
49.22
73.66
97.18
146.36
193.7
242.92
288.94
317.5
363.52
409.34
455.62
501.84
548.08
-

188.92
236.58
281.02
307.94
354.02
398.28
442.92
489.14
532.22
-

92.04
139.76
182.58
230.22
273.1
300.02
344.48
387.14
431.8
476.44
517.96
-

177.86
222.3
266.74
292.1
333.34
377.66
419.1
463.74
505.26
-

22.28
42.82
66.64
87.32
131.78
173.08
215.94
257.26
284.18
325.42
366.52
407.98
451.04
490.92
-

293701913.xls

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
20 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99
(1)

(2)

INPUT
Line Number

3"-PW-AC-2033/34/35/36

3"-PW-AC-2020/37

-25H-ET

-25H-ET

Liquid
Liquid

Liquid
Liquid

35.0

39.0

[kPaa]

101.33

450.00

[kg/h]

4,500

4,500

0%

0%

[kg/h]

4,500

4,500

[kg/m]

900.00

900.00

[cP]

0.800

0.800

[mm]

80

80

Piping Specification

AC
AC

AC
AC

ANSI Rating

150#

150#

40
40

40
40

77.9

77.9

Mass & Energy Balance Stream No.


PROCESS DATA

1) Diesel to heat medium heaters

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density
Actual Viscosity

(P&ID: JAB-CPF1-PID-2167-1 Rev. 1)

Flowrate : Vendor specified.

Properties: Diesel transfer pumps (P-5446A/B) datasheet

2) Diesel to PS#2
Flowrate : Vendor specified

Properties: Diesel transfer pumps (P-5446A/B) datasheet

LINE SPECIFICATION
Nominal Diameter

Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

0.00477

0.00477

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

0.29

0.29

25,530

25,530

0.026

0.026

[kPa/100m]

1.27

1.27

[m/s]

1.0

1.8

Vapour Criteria

5 - 14

23 - 35

Liquid Criteria

[kPa/100m]

CONCLUSIONS
Therefore the recommended line size for 3"-PW-AC-2033/34-25H-ET is

80

mm NB

Therefore the recommended line size for 3"-PW-AC-2020-25H-ET is

80

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Open Drain1

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
21 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99

INPUT
Line Number

3"-PW-AC-2021/38

3"-CO-AC-1233/34/35/36

-25H-ET

-25H-ET

1. Open Drain Sump Pump Discharge lines

Liquid
Liquid

Liquid
Liquid

2. Closed Drain Sump Pump Discharge lines

35.0

35.0

[kPaa]

450.00

101.33

[kg/h]

9,000

13,500

0%

0%

[kg/h]

9,000

13,500

[kg/m]

900.00

900.00

[cP]

0.800

0.800

[mm]

80

80

Piping Specification

AC
AC

AC
AC

ANSI Rating

150#

150#

40
40

40
40

77.9

77.9

Mass & Energy Balance Stream No.


PROCESS DATA
Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density
Actual Viscosity
LINE SPECIFICATION
Nominal Diameter

Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

0.00477

0.00477

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

0.58

0.87

51,060

76,600

0.023

0.022

[kPa/100m]

4.48

9.49

[m/s]

1.8

1.0

Vapour Criteria

23 - 35

5 - 14

Liquid Criteria

[kPa/100m]

CONCLUSIONS
Therefore the recommended line size for 3"-PW-AC-2021/38-25H-ET is

80

mm NB

Therefore the recommended line size for 3"-CO-AC-1233/34/35/36-25H-ET is

80

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Open Drain2

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
22 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99

INPUT
Line Number

4"-CO-AC-1238/48-25H-ET

Mass & Energy Balance Stream No.

Closed Drain Pump Common Discharge

PROCESS DATA

Liquid
Liquid

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

35.0

[kPaa]

450.00

[kg/h]

27,000

Design Margin
Design Flow
Actual Density
Actual Viscosity

Liquid
Liquid

0%
[kg/h]

27,000

[kg/m]

900.00

[cP]

0.800

[mm]

100

LINE SPECIFICATION
Nominal Diameter
Piping Specification

AC
AC

AC
AC

ANSI Rating

150#

150#

40
40

40
40

Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

PIPE ID

102.3

CS

CS

CS

0.046

0.046

0.00821

#VALUE!

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

1.01

#DIV/0!

116,730

#DIV/0!

0.020

#DIV/0!

[kPa/100m]

8.97

#DIV/0!

[m/s]

2.5

1.0

Vapour Criteria

23 - 35

5 - 14

Liquid Criteria

[kPa/100m]

CONCLUSIONS
Therefore the recommended line size for 3"-PW-AC-2021/38-25H-ET is
Therefore the recommended line size for 3"-CO-AC-1233/34/35/36-25H-ET is

100

mm NB

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Open Drain3

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
23 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99

INPUT

JAB-CPF1-PID-2177-1

Line Number

8"-SW-A-4503

Mass & Energy Balance Stream No.

Discharge line of Pre-Treatment Water Transfer

PROCESS DATA

Pump, P-5446A/B

Liquid
Liquid

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Actual Density
Actual Viscosity

Rated Capacity 42.0 m3/hr

47.5

[kPaa]

301.33

[kg/h]

42,000

Design Margin
Design Flow

Liquid
Liquid

Properties taken from Pre-Treatment Water


Transfer Pump, P-5446A/B datasheet.

0%
[kg/h]

42,000

[kg/m]

1000.00

[cP]

1.000

[mm]

100

LINE SPECIFICATION
Nominal Diameter
Piping Specification
ANSI Rating
Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

A
A

A
A

150#

150#

40
40

20
20
PIPE ID

102.3

CS
[mm]

CS

CS

CS

0.046

0.046

0.00821

#VALUE!

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

[kPa/100m]
[m/s]
[kPa/100m]

1.42

#DIV/0!

145,260

#DIV/0!

0.019

#DIV/0!

19.04

#DIV/0!

1.5 - 2.1

4.3

Vapour Criteria

6 - 45

35 - 45

Liquid Criteria

CONCLUSIONS
Therefore the recommended line size for 8"-SW-A-4503 is

100

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Treated Water1

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
24 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99

INPUT
Line Number

8"-UW-A-4154/55/56

6"-UW-A-4157/58

Liquid
Liquid

Liquid
Liquid

35.0

35.0

[kPaa]

101.33

201.33

[kg/h]

42,000

42,000

0%

0%

[kg/h]

42,000

42,000

[kg/m]

Mass & Energy Balance Stream No.


PROCESS DATA

1. Water from Treatment package to Storage Tanks

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density
Actual Viscosity

1000.00

1000.00

[cP]

0.800

0.800

[mm]

200

150

A
A

AC
AC

150#

150#

20
20

40
40

206.4

154.1

2. Water from Tanks to further treatment

LINE SPECIFICATION
Nominal Diameter
Piping Specification
ANSI Rating
Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

0.03346

0.01865

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

0.35

0.63

89,960

120,510

0.019

0.019

[kPa/100m]

0.57

2.41

[m/s]

2.5

1.5

Vapour Criteria

23 - 35

5 - 14

Liquid Criteria

[kPa/100m]

CONCLUSIONS
Therefore the recommended line size for 8"-UW-A-4154/55/56 is

200

mm NB

Therefore the recommended line size for 6"-UW-A-4157/58 is

150

mm NB

Line no changes

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Treated Water2

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
25 of
26

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99

INPUT
Line Number

3"-UW-A-4029/30

2"-UW-A-4166/68

Mass & Energy Balance Stream No.

1. Treated Water to Users

PROCESS DATA

Liquid
Liquid

Liquid
Liquid

35.0

35.0

[kPaa]

501.33

501.33

[kg/h]

21,000

8,400

0%

0%

[kg/h]

21,000

8,400

[kg/m]

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density
Actual Viscosity

1000.00

1000.00

[cP]

0.800

0.800

[mm]

80

50

A
A

A
A

150#

150#

40
40

40
40

77.9

52.5

2. Potable Water to users

LINE SPECIFICATION
Nominal Diameter
Piping Specification
ANSI Rating
Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

0.00477

0.00216

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

[kPa/100m]

1.22

1.08

119,150

70,760

0.020

0.023

19.57

25.23

1.8

1.8

Vapour Criteria

23 - 35

23 - 35

Liquid Criteria

[m/s]
[kPa/100m]

CONCLUSIONS
Therefore the recommended line size for 3"-UW-A-4029/30 is

80

mm NB

Therefore the recommended line size for 2"-UW-A-4166/68 is

50

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Treated Water3

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
26 of
26

Note: You can co


worksheet by usin
Copy Worksheet

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99

INPUT
Line Number

3"-UW-A-4029/30

Mass & Energy Balance Stream No.

Treated Water to Users

PROCESS DATA

Liquid
Liquid

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

35.0

[kPaa]

501.33

[kg/h]

37,800

[kg/h]

37,800

[kg/m]

1000.00

Design Margin
Design Flow
Actual Density
Actual Viscosity

Liquid
Liquid

0%

[cP]

0.800

[mm]

80

LINE SPECIFICATION
Nominal Diameter
Piping Specification
ANSI Rating
Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

A
A

150#

150#

80
80

40
40
PIPE ID

73.7

CS
[mm]

A
A

CS

CS

CS

0.046

0.046

[m]

0.00426

#VALUE!

[m/s]

2.46

#DIV/0!

226,870

#DIV/0!

0.019

#DIV/0!

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity
Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

[kPa/100m]
[m/s]
[kPa/100m]

79.83

#DIV/0!

0.6 to 4.8

1.8

Vapour Criteria

6 to 45

23 - 35

Liquid Criteria

CONCLUSIONS
The velocity is in the middle of the range, and while the pressure drop is higher than recommended this is only an intermittent
stream flow at this high rate.

80

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Treated Water4

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
23 of
26

Note: You ca
worksheet by
Copy Worksh

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99

INPUT

Line Number

JAB-CPF1-PID-2177-1

8"-SW-A-4501

Mass & Energy Balance Stream No.

1. White Nile River Water Lift Pumps, P-5468A/B

Pump P-5468A/B

PROCESS DATA

discharge line.

Liquid
Liquid

Liquid
Liquid

Rated capacity 71.0 m3/hr. (During raining season)

47.5

0.0

Properties taken from White Nile River Water Lift

[kPaa]

301.33

0.00

Pumps, P-5468A/B datasheet.

[kg/h]

85,200

0%

0%

[kg/h]

85,200

[kg/m]

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Design Margin
Design Flow
Actual Density

1200

[cP]

1.1

1.1

[mm]

150

150

AA

A
A

ANSI Rating

150#

150#

Pipe Schedule

40
40

40
40

154.1

154.1

Actual Viscosity
LINE SPECIFICATION
Nominal Diameter
Piping Specification

Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

0.01865

0.01865

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

1.06

#DIV/0!

177,790

#DIV/0!

0.018

#DIV/0!

7.86

#DIV/0!

[m/s]

1.8 to 4.3

2.1 - 2.7

Vapour Criteria

[kPa/100m]

35 to 45

6 - 45

Liquid Criteria

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

[kPa/100m]

CONCLUSIONS
Therefore the recommended line size for Pump, P-5468A/B dischrge is

150

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Treated Water5

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Oil Development Package A


Petrodar Operating Company Limited
Utility Line Sizing

Project title
Client
Calculation title
Activity

(CPF)-CA-PRO-010
4211095
Detailed
23 of
26

Note: You ca
worksheet by
Copy Works

File

REVISION

DATE

6-Sep-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99

INPUT

Line Number

6"-SW-A-4502

4"-SW-A-4503

Mass & Energy Balance Stream No.

P-5466 Suction

P-5466 Discharge

JAB-CPF1-PID-2177-1

1. Raw Water Pre-treatment Package A-5463

PROCESS DATA

discharge line.

Liquid
Liquid

Phase
Temperature, T
Pressure, P
Mass Flowrate

[C]

Actual Density
Actual Viscosity

Rated capacity 71.0 m3/hr

47.5

47.5

[kPaa]

301.33

301.33

2. Suction line of Pre-Treatment Water Transfer

[kg/h]

43,000

43,000

Pump, P-5446A/B

0%

0%

43,000

43,000

Design Margin
Design Flow

Liquid
Liquid

[kg/h]

Rated Capacity 42.0 m3/hr

[kg/m]

1000

1000

Properties taken from Pre-Treatment Water

[cP]

1.000

1.000

Transfer Pump, P-5446A/B datasheet.

[mm]

150

100

AA

AA

LINE SPECIFICATION
Nominal Diameter
Piping Specification
ANSI Rating

150#

150#

Pipe Schedule

40
40

40
40

154.1

102.3

Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

0.01865

0.00821

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

0.64

1.45

98,700

148,720

0.020

0.019

[kPa/100m]

2.60

19.90

[m/s]

1.5

2.5

Vapour Criteria

1 to 5

23 - 35

Liquid Criteria

[kPa/100m]

CONCLUSIONS
Therefore the recommended line size for A-5463 discharge line, Raw Water is

150

mm NB

Therefore the recommended line size for P-5466A/B discharge line, Raw Water is

100

mm NB

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77

file:///var/www/apps/conversion/tmp/scratch_2/293701913.xls

293701913.xls Treated Water6

CALCULATION SHEET
Calc no
Proj no
Phase/CTR
Page

Melut Basin Development Package A


Petrodar Operating Company Limited
Process Line Sizing

Project title
Client
Calculation title
Activity

FPF-010
4211095
Detailed
43
of

Note: You can c


worksheet by us
Copy Workshee

File

REVISION

DATE

24-Nov-04

BY

CHECKED

APPROVED

REVISION

DATE

BY

CHECKED

11-Feb-05

PWH

APPROVED

SINGLE PHASE PRESSURE DROP (LIQUID OR GAS)


ACCORDING TO CRANE AND CHURCHILL (SI UNITS)
Standard Calculation 086/00589-PR-CA-002, Rev. 0, "Issued for Use", 18-Feb-99

INPUT

(P&ID: JAB-CPF1-PID-2177-1)

Line Number

3"-SW-A-4504

Mass & Energy Balance Stream No.

6"-SW-A-4504

Sediment Disposal Line Sediment Disposal Line Sediment disposal line

PROCESS DATA

Rated capacity 37.0 m3/hr

Liquid
Liquid

Liquid
Liquid

[C]

50

50

and 1.3 cP considering the water mix with the

[kPaa]

200

200

sludge.

36,400

36,400

0%

0%

[kg/h]

36,400

36,400

[kg/m]

Phase
Temperature, T
Pressure, P
Mass Flowrate

[kg/h]

Design Margin
Design Flow
Actual Density
Actual Viscosity

1300.00

1300.00

[cP]

1.3

1.3

[mm]

80

150

A
A

A
A

150#

150#

40
40

40
40

77.9

102.3

Denstity and viscosity assumed as 1300 kg/m3

LINE SPECIFICATION
Nominal Diameter
Piping Specification
ANSI Rating
Pipe Schedule
Pipe Internal Diameter

[mm]

User Input Pipe ID

[mm]

Material of Construction
Pipe Roughness

CS
[mm]

CS

CS

PIPE ID

CS

0.046

0.046

0.00477

0.00821

OUTPUT
Pipe Cross-sectional Area
Fluid Velocity

[m]
[m/s]

Reynolds Number
Darcy Friction Factor
Pressure Drop
Velocity Design Range
DP Design Range

[kPa/100m]
[m/s]
[kPa/100m]

1.63

0.95

127,090

96,840

0.020

0.020

44.92

11.56

1.5 - 2.4

1.5 - 2.4

Vapour Criteria

110.0

110.0

Liquid Criteria

CONCLUSIONS
Therefore the recommended line size for sediment disposal line is

80

mm NB

However due to high sediment loading and associtated wear:

150

mm NB is recommended

REFERENCES
1) Crane, "Flow of Fluids through Valves, Fittings, and Pipe", 1992, Metric Edition - SI Units
2) Churchill S.W., "Friction-factor equation spans all fluid-flow regimes", Chem. Eng., 7-Nov-77