High Performance Liquid Chromatography

(HPLC)
Chromatography is a broad range of physical methods used to separate and to
analyze complex mixtures. The components to be separated are distributed between two
phases: a stationary phase bed and a mobile phase which percolates through the
stationary bed.
The stationary phase in HPLC refers to the solid support contained within the column
over which the mobile phase continuously flows. The sample solution is injected into the
mobile phase of the assay through the injector port. As the sample solution flows with the
mobile phase through the stationary phase, the components of that solution will migrate
according to the non-covalent interactions of the compounds with the stationary phase.
The chemical interactions of the stationary phase and the sample with the mobile phase,
determines the degree of migration and separation of the components contained in the
sample. For example, those samples which have stronger interactions with the stationary
phase than with the mobile phase will elute from the column less quickly and thus have a
longer retention time, while the reverse is also true. Columns containing various types of
stationary phases are commercially available. Some of the more common stationary
phases include:
Adsorption chromatography: The stationary phase is an adsorbent (like silica gel or any
other silica based packings) and the separation is based on repeated adsorption-desorption
steps.
Ion exchange chromatography: The stationary bed has an ionically charged surface of
opposite charge to the sample ions. This technique is used almost exclusively with ionic

or ionizable samples. The stronger the charge on the sample, the stronger it will be
attracted to the ionic surface and thus, the longer it will take to elute. The mobile phase is
an aqueous buffer, where both pH and ionic strength are used to control elution time.
Size exclusion chromatography: The column is filled with material having precisely
controlled pore sizes, and the sample is simply screened or filtered according to its
solvated molecular size. Larger molecules are rapidly washed through the column;
smaller molecules penetrate inside the porous of the packing particles and elute later. This
technique is also called gel filtration or gel permeation chromatography although, today,
the stationary phase is not restricted to a "gel".
Normal and reversed-phase chromatography: These are defined depending on the relative
polarity of the two phases.
In normal phase chromatography, the stationary bed is strongly polar in nature (e.g., silica
gel), and the mobile phase is nonpolar (such as n-hexane or tetrahydrofuran). Polar
samples are thus retained on the polar surface of the column packing longer than less
polar materials.
Reversed-phase chromatography is the inverse of this. The stationary bed is nonpolar
(hydrophobic) in nature, while the mobile phase is a polar liquid, such as mixtures of
water and methanol or acetonitrile. Here the more nonpolar the material is, the longer it
will be retained.
Above mentioned types cover almost 90% of all chromatographic applications. Eluent
polarity plays the highest role in all types of HPLC. There are two elution types: isocratic
and gradient. In the first type constant eluent composition is pumped through the column

during the whole analysis. In the second type, eluent composition (and strength) is
steadily changed during the run.
Detectors
The detector for an HPLC is the component that emits a response due to the eluting
sample compound and subsequently signals a peak on the chromatogram. It is positioned
immediately posterior to the stationary phase in order to detect the compounds as they
elute from the column. The bandwidth and height of the peaks may usually be adjusted
using the coarse and fine tuning controls, and the detection and sensitivity parameters
may also be controlled (in most cases). There are many types of detectors that can be
used with HPLC. Some of the more common detectors include: Refractive Index (RI),
Ultra-Violet (UV), Fluorescent, Radiochemical, Electrochemical, Near-Infra Red (NearIR), Mass Spectroscopy (MS), Nuclear Magnetic Resonance (NMR), and Light
Scattering (LS).