210l water butt with base, lid,


tap and overflow connected
to downpipe as per MJA
Consulting

Sect
A-A

Do Not scale off this drawing, use only figured


dimensions and report any discrepancies or
omissions to the Architect immediately.

rev. date

9490
1340

1500

1672

300

1500

1163

1200

1115
300

100
5129

300

3660

Amended to as per TW comments


and Issued for Construction
Pending Suppliers Approval

JUN'10

C
D
E

Aug'10
Jan'11
Feb'11

WC Door amended to swing


outwards
Dims to internal doors added
Front door size changed to 1004mm
Plots 76, 88, & 146 removed, Plots
74, 67, & 69 added
Plot 151 Added
Plot 151 Shower Vert Added

F
G

Jul'11
Aug'11

Sept'11

Plot 67 Handing changed to as


Shown

Oct'12

Blockwork wall to side of store


amended, and level thershold to the
rear.

Boiler flue
outlet

Level Threshold
HD/K-100

MAR'10

300

rwp

description

HD/K-100
HD/K-100
SVP

Blr
Washing
Machine
op. extra

Breakfast

Dining

BOX/K-100
25

St.

4050

Wall mounted gas


meter position

75

2125

7878

Wall mounted elec.


meter position

FD

30

13
8

4142

2461

75

793

5
5073

Water meter position

REFER TO STANDARD DETAILS 28/40h-49h FOR DETAIL OF


RAMP/LEVEL STANDING TO FRONT DOOR

Blockwork wall
built off slab

Semi concealed
gas meter position

685

54

WC

2930

1025

1025

S/K-100

SVP

838

8478

Fridge
Freezer
op. extra

BOX/K-100
100

Refer to Standard
Taylor Wimpley
Stair Drawing

30 Minutes Fire Resisting Construction


Any doors/access panels in/out of these
enclosures to be FD30 panels/doors.
All partitions to the perimeter of the
protected lobby to be built upto underside
of floor.
100

1080

Cooker hood
extract route

3040
420

FD30 838

838

100

5770

686

838

SVP & Shower Vert


to Plot 151 Only

3635

1st Floor Joists

3217

1116

4315

2729

Kitchen

1st Floor Joists

75

Dish Washer
op. extra

83

Note:
Party Walls between dwellings to comply with Robust Standard
Detail RSD E-WM-11

175

1198

3478

Family
Room

3043

1st Floor Joists

Hall

Trimmer
1st Floor Joists
Trimmer

Lounge

2324

910

project

Wallmounted
Gas. meter
position
Wallmounted
elec. meter
position

FD30 838

client

drawing

100

Level Threshold

3660

75

1845

970
300

1350

225

1660

1782

1004

3210

status

225

Posts supporting
canopy
1010

533

HD/K-100

rwp

300

HD/K-100
300

HD/K-100

225

Entrance Canopy
1008

1586

8890

Entrance Canopy
Structural items by
Supplier
1350

PLOTS

970
300

-67
-69
-74
-151

(As Shown) - Fronting IDO


(As Shown) - Fronting IDO
(As Shown) - Fronting IDO
(Opposite) - Fronting IDO

scale

1/50 @ A3

date

Ground Floor Plan

author
20/10/09

drg no.

PS
rev.

This drawing is the copyright of Roberts Limbrick Ltd


and should not be reproduced in whole or in
part or used in any manner whatsoever without
their written permission.

SERVICES LEGEND
rwp
LE

rev. date
A

PIR OUTDOOR SECURITY LIGHT


(automatic night time only)

3610mm
[11'-10"FT]

SVP

PENDANT LIGHT FITTING

Blr

LOW VOLTAGE INTERNAL WALL LIGHT


BATTEN HOLDER LIGHT FITTING

Breakfast

Dining

2704mm
[8'-10"FT]

Do Not scale off this drawing, use only figured


dimensions and report any discrepancies or
omissions to the Architect immediately.

ENERGY EFFICIENT LIGHTING


4-PIN CFL PENDANT FITTING

AP
5105mm

ENERGY EFFICIENT LIGHTING


BATTEN HOLDER FITTING

Kitchen

description
Amended to as per TW comments
and Issued for Construction
Pending Suppliers Approval

JUN'10

WC Door amended to swing


outwards

Nov'10

External PIR Light shown and


13amp fused spur added for alarm
in hall

Feb'11

Feb'11

Plots 76, 88, & 146 removed, Plots


74, 67, & 69 added
Plot 151 added

F
G

Aug'11
Sept'11

Nov'12

Plot 151 Shower Vert Added


Plot 67 Handing changed to as
Shown
CO monitor & external lighting added

ELECTRICAL:

FLUORESCENT STRIP LIGHT

[16'-9"FT]

MAR'10

3585mm

[11'-9"FT]

LE
G

SPOT LIGHTS ON TRACK (Number of lights shown)


LOW VOLTAGE RECESSED DOWNLIGHT
(refer to THD National Construction Specification for
Trad build houses in England and Wales Clause 26.3)
LIGHT SWITCH

SVP & Shower Vert


to Plot 151 Only

NEON INDICATOR LIGHT SWITCH

2 WAY LIGHT SWITCH


1 GANG 3 MODULE SWITCH PLATE (LIGHT/FAN/FUSE)
UNSWITCHED SOCKET OUTLET (low level) single/double
UNSWITCHED SOCKET OUTLET (w/t level) single/double

AP T

St.

UNSWITCHED SOCKET OUTLET (high level) single/double


SWITCHED SOCKET OUTLET (low level) single/double

SVP

SWITCHED SOCKET OUTLET (w/t level) single/double

SWITCHED SOCKET OUTLET (high level) single/double


SHAVER UNIT

WC

FUSED SPUR (low level)

5073mm

[16'-8"FT]

3610mm
[11'-10"FT]

FUSED SPUR (w/t level)

FUSED SPUR (high level)

SWITCHED FUSED SPUR (low level)

4
LE

3043mm

Hall

SWITCHED FUSED SPUR (high level)

Family
Room

[10'-0"FT]

Lounge

LE
t

COOKER CONTROL UNIT INCORPORATING A


SWITCHED SOCKET OUTLET

45amp

LE

[10'-6"FT]

SWITCHED FUSED SPUR WITH NEON INDICATOR


ABOVE WORKTOP CONNECTED TO UNSWITCHED
SOCKET OUTLET BELOW

AP T

SWITCHED FUSED SPUR ABOVE WORKTOP


CONNECTED TO UNSWITCHED SOCKET OUTLET
BELOW
MULTIGANG SWITCHED FUSED SPUR ABOVE
WORKTOP CONNECTED TO UNSWITCHED SOCKET
OUTLETS TO APPLIANCES

AP
Telephone
entry point

45 amp COOKER CONTROL SWITCH WITH NO


SOCKET OUTLET
COOKER TAIL PLATE OR UNSWITCHED SOCKET
OUTLET - TO SUIT COOKER POWER RATING

AP N
3206mm

rwp

SWITCHED FUSED SPUR (w/t level)


SWITCHED FUSED SPUR WITH NEON INDICATOR
(light switch level)

2
1

IP rating for light fitting to bathrooms to be suitable for zone in


which it is to be positioned

EX

EXTRACT FAN ISOLATING SWITCH (2000mm above FFL)

project

EXTRACT / WHOLE HOUSE VENTILATION GRILLE / FAN


IMMERSION HEATER

client

30 Minutes Fire Resisting Construction


Any doors/access panels in/out of these
enclosures to be FD30 panels/doors.
All partitions to the perimeter of the
protected lobby to be built upto underside
of floor.

drawing

status

Wall mounted gas


meter position
Wall mounted elec.
meter position

Semi concealed
gas meter position
Water meter position
PLOTS

REFER TO STANDARD DETAILS 28/40h-49h FOR DETAIL OF


RAMP/LEVEL STANDING TO FRONT DOOR
Note:
Party Walls between dwellings to comply with Robust Standard
Detail RSD E-WM-11

-67
-69
-74
-151

(As Shown) - Fronting IDO


(As Shown) - Fronting IDO
(As Shown) - Fronting IDO
(Opposite) - Fronting IDO

scale

1/50 @ A3

date

author
20/10/09

drg no.

AR
rev.

You might also like