You are on page 1of 16

Blood Collection System

Contents

Page

Operation Sequence of d-vac


Vacuum Blood Collection Device

Non-anticoagulation Tube

Pro-coagulation Tube

Oxalate Tube

Gel and Clot Activator Tube

EDTA Tube

Heparin Tube

ESR Tube

10

PT Tube

11

d-vac Multi-Sample Needle


and Operation Sequence

12-13

Product Specifications

14-16

Accessories

16

Oxalate
d-vac Oxalate Tubes contain a series of oxalate anticoagulant agents.
By using an inhibitor and special inside treatment, the blood sample
can be preserved for a longer period without its original status being
changed and the metabolism of blood cells almost cease.
Oxalate Tubes are widely used to collect blood for glucose
determinations. Sodium fluoride is used in Glucose tubes as glycolysis
inhibitor to preserve glucose when combined with anticoagulant potassium
oxalate.

Colour Code:
Tube Size:
Volume:
Anticoagulant:

Anticoagulant Status:
Vertical Static Pressure:
Mixing Mode:
Allowed Operation Temperature:
Ultimate Centrifugal Speed:
Blood Storage Time:

13x100mm, 13x75mm
2ml, 3ml, 4ml, 5ml, 6ml, 7ml
Potassium Oxalate, Ammonium Oxalate,
Potassium Oxalate/Sodium Fluoride,
Bioxalate Sodium Fluoride
Biphase Agents or Powder
More than 16kg/cm
After collecting, immediately gently invert the tube to 180 3 to 5 times.
0C - 3C
5000rpm
72hrs in normal temperature (Blood-sugar value)

Deviation for Collect Volume:

10% (at the allowed environment


temperature scale)

Corresponding Altitude Error:

200m

Applicable Area and Altitude:

See the package

Note:

Grey

The blood specimen is not suitable for biochemical


and cell morphologic tests.

Gel and Clot Activator


d-vac Gel and Clot Activator Tubes are used to collect blood
for clinical biochemistry and immunology. They can improve serum
surface
and prevent substance exchange between blood cell and serum.
Guaranteeing biochemical character and chemical components
of serum unchanged evidently for a long time, which do not need
to use special tool to transport serum.

Colour Code:
Tube Size:
Volume:
Gel Weight:
Vertical Static Pressure:

Jacinth
16x125mm, 16x100mm, 13x100mm, 13x75mm
2ml, 3ml, 4ml, 5ml, 6ml, 7.5ml, 8.5ml, 9.5ml, 11ml, 13ml
0.7g-0.8g
8kg/cm

Recommended Centrifugation Speed:

3500rpm

Ultimate Centrifugal Speed:

5000rpm

Mixing Mode:
Complete Clotting Time:
Blood Natural Contraction Initial Time:
Inside Natural Negative Electric Charge:
Allowed Operation Temperature:
Maximum Error Rate of Vacuum Grade:

After collecting, immediately gently invert the tube to 180 3 to 5 times.


30mins
Approx 30mins
30%
0C -37C
10% (at the allowed environment temperature scale)

Corresponding Altitude Error:

200m

Applicable Area and Altitude:

See the package

Note:

These tubes are not fit for PCR test.

EDTA
d-vac EDTA Tubes use EDTA. K2, EDTA. K3 as additives.
They are widely used to collect blood for clinical hematology
examinations and are suitable for blood cell analyser.

Colour Code:
Tube Size:

16x100mm, 13x100mm, 13x75mm

Volume:

1ml, 2ml, 3ml, 4ml, 5ml, 6ml, 7ml, 10ml

Inner Wall Electric Charge:


Anticoagulant Status:
Vertical Static Pressure:
Mixing Mode:
Stopper Hardness:
EDTA. K2, EDTA. K3 Concentration ISO6710:
Allowed Operation Temperature:
Maximum Error Rate of Vacuum Grade:

0
Liquid, Powder
More than 16kg/cm
After collecting, immediately gently invert the tube to 180
5 to 8 times.

38A
1995
0C - 37C
10% (at the allowed environment temperature scale)

Corresponding Altitude Error:

200m

Applicable Area and Altitude:

See the package

Note:

Lavender

In special cases, if a syringe is required to collect blood,


please remove the needle header and then inject for the
quantitative blood, preventing the leakage of anticoagulant.

Heparin
d-vac Heparin Tubes are widely used in blood collection and
anticoagulation for clinical biochemical examinations, emergency
biochemical tests and also some items of hemorrheology.
They have the advantages of fast clotting, being fit for a wide range
of temperatures and are highly compatible with serum sample
quato.

Colour Code:
Tube Size:
Volume:
Anticoagulant:

Green
16x100mm, 13x100mm, 13x75mm
2ml, 3ml, 4ml, 5ml, 6ml, 7ml, 10ml
Heparin Lithium, Heparin Sodium

Heparin Concentration:

ISO6710:1995

Vertical Static Pressure:

More than 16kg/cm

Mixing Mode:
Allowed Operation Temperature:
Anticoagulant Status:
Ultimate Centrifugal Speed:
Blood Storage Time:
Maximum Error Rate of Vacuum Grade:

After collecting, immediately gently invert the tube to 180


3 to 5 times.
0C - 37C
Hyaline Velum Additive (powder), Flocculent Powder
5000rpm
Less than 6hrs in room temperature
10% (at the allowed environment temperature scale)

Corresponding Altitude Error:

200m

Applicable Area and Altitude:

See the package

Note:

1.
2.
3.

Caution:

Most of the indexes are not effected after routine


biochemical serum is changed into plasma.
The collection amount should be as sufficient as required
to avoid the increase of relative density of heparin, which
will effect the measure of calcium and ferment.
The test result is unlikely to be repeated when sample is
kept 6 hours after collection, especially for the index of
AST, ALT, TBIL, DBIL, GGT.

Different test method will bring different influence.

ESR
d-vac ESR Tubes are used for blood collection and
anticoagulation in sedimentation rate testing.
The measurement refers to the Westergren
method.

Colour Code:
Tube Size:
Volume:
Anticoagulant:
Anticoagulant Status:
Volume Ratio Between Anticoagulant and Blood:
Vertical Static Pressure:
Mixing Mode:

10

Black
13x100mm, 13x75mm
1.6 ml, 2.4ml
0.129mol/L Sodium Citrate
Liquid
1:4
More than 16kg/cm

After collecting, immediately gently invert the tube to


180 3 to 5 times.

PT
d-vac PT Tubes are blood collection tubes, using 0.129mol/L
Sodium Citrate as anticoagulant, whose Volume Ratio is 1 to 9
(1:9) compared with blood sample volume.
PT Tubes are mainly used to collect blood for coagulation testing,
with the advantage of high accuracy in matching between the
proportion of blood and anticoagulant.

Colour code:
Tube Size:
Volume:
Anticoagulant:
Anticoagulant Status:
Mixing Mode:

Vertical Static Pressure:


Volume Ratio Between Anticoagulant and Blood:
Allowed Operation Temperature:

Blue
13x100mm, 13x75mm
1.8ml, 2.7ml, 3.6ml, 4.5ml
Sodium Citrate 0.129mol/L
Liquid
After collecting, immediately gently invert the tube
to 180 3 to 5 times.
More than 16kg/cm
1:9
0C - 37C

11

d-vac Multi-Sample Needle


for More Precision and Reliability
Safe and User Friendly
d-vac Multi-Sample Needles have been
designed to greatly reduce risk of
contamination and eliminate direct
user-contact with blood sample.

Leak Proof Needle


Simultaneously on removing the needle
from tube, the needle is covered and
closed off, resulting in a guaranteed leak
proof needle.

Smooth Sharp Needle

Maximum patient awareness minimises patient


discomfort, d-vac coated needles are sharp
and smooth minimising pain during penetration.

d-vac Collection Needles


TM

Kink Resistant Tubing


Excellent blood flow, through kink resistant tubing.

Soft wings allow for easier veinpuncture

Luer adaptor

12

Operation Sequence of d-vac


Vacuum Blood Collection Device
with multi sample needle and holder
1. Select an appropriate tube for intended test
and remove cover from the Multi-Sample Needle.
Attach the needle to the holder and screw until tight.

2. Carry out routine disinfection.


Select puncture site and perform veinpuncture.

3. Push tube into holder, puncturing stopper.


Center tube in holder to prevent sidewall penetration
and premature vacuum loss.
Remove tube from holder as soon as it is filled to stated volume.
Do not allow contents of tube to contact the stopper
or the end of the needle during these procedures.

4. If multiple blood sample needle is necessary, remove tube and place


new tube into the holder. Repeat procedure from step 3.

5. As soon as blood stops flowing into the last tube, remove


needle from vein, applying pressure to puncture site with
dry sterile swab until bleeding stops. Invert the tube 5-8
times to mix the blood.

6. Dispose of the needle with an appropriate device.

13

You might also like