Vista-15 & -20

Alarm
Output - 4
(Ground)

4.7K

+12V 11

Battery

#2
#1 Battery

8-Pin Trigger Connector

4.7K
ALARM SIREN SOUNDS
No special programming
required.
Wireless Siren follows
hardwired siren pattern.

#2
#1

#2
#1

RE150 Special Transmitter

Out2 10

#2
#1

#2
#1 Battery

Output
17

4.7K

Resolution RE116-U Wireless Siren


Transmitter Connection on
GE/UTC Systems

Concord 4

ENTRY OR EXIT BEEP SOUNDS (Cannot do both Alarm sounds


and Entry Exit Beep sounds because different wiring required)
*79 Relay Programming
Output: #17
0 Normally Low (0=no)
Output Type: 0 (not plc or relay)
*80 Output Function
Activated by: 2 Zone Type
Zone Type: 21 (Arming-Away) For Exit beeps or...
Zone Type: 32 (Start of Entry Time) For Entry Beeps
Output Action: 3 (pulse 1 sec)

Simon XT

HW1&2
DC out

4.7K

#2
#1

#2
#1

#2
#1 Battery

GND

4.7K
Mount near
Transmitter

Select output (0-12)


[11] follows internal sounder alarm (and status)

Siren will not function in the above mode


when panel has lost AC power.
1/14/2013
GE & 2GIG

Q21

RE150 Special Transmitter

RE116-U Siren Hardware Connections

Q78

BELL +

Battery

Honeywell

Battery

Device 4 to sound Entry beeps:


Type: Trigger Output
Action: Pulsing
Start Zone Type: Entry Exit 2
(Entry Exit 2 is usually used for zones far away, where youd use this remote
siren)
Stop System Operation: Disarm

4.7K
Mount near
Transmitter

BELL -

#2
#1

Device 3 to sound Exit beeps:


Type: Trigger Output
Action: Pulsing
Start System Operation: Arm Away
Stop System Operation: End of Exit Delay

Optional: Follows Siren only


(frees up Open Collector)

#2
#1

Device 2 to sound on Fire Alarms:


Type: Trigger Output
Action: Permanent
Start System Operation: Any Fire Alarm
Stop System Operation: Bell Timeout

#2
#1

#2
#1 Battery

Siren will not function in the above mode


when panel has lost AC power.

1/14/2013

Open
Collector

RE150 Special Transmitter

#2
#1

HWZ
EGND

Preferred: Follows Siren AND Status Beeps

#2
#1

GND

RE150 Special Transmitter

TRIG

HW Siren Sup can be used, since 4.7K is present

Resolution RE116-U Wireless Siren


Transmitter Connection on
2GIG System

14DVC +
4.7K

Settings here (such as Piezo Beeps


Siren Options
and Panel Piezo Alrm) only affect sounds the panel
itself makes; Wireless Siren will make sounds either
way.

Battery -

Go! Control
Device 1 to Sound on Burg Alarms:
Type: Trigger Output
Action: Permanent
Start System Operation: Any Burglary Alarm
Stop System Operation: Bell Timeout

+9VDC

Battery +

ALARM SIREN AND STATUS SOUNDS


Panel comes defaulted to follow Alarm & Status Beeps
Programming Settings (for reference):
System Options
HW1 function = 1 (Alarm & Status)
HW1 function = 5 (Alarm only)

Siren will not function in this mode when


panel has lost AC power.

Under Devices, create...

Lynx Touch 5xxx

9 VAC in

Battery

Ground - 8

ALARM SIREN SOUNDS


No special programming
required.
Wireless Siren follows
hardwired siren pattern.

RE150 Special Transmitter

#2
#1

4.7K

System Event Trigger Options:


Any audible alarm (Alarm only) = 004All system noises (Alarm and status beeps) = 017-

HW1 I/O

9 VAC in

RE150 Special Transmitter

Sound 9
Out +

ALARM SIREN OR STATUS SOUNDS


Panel comes defaulted to follow Alarm & Status Beeps
With Trigger and response: 017-10

Response Characteristics:
Siren Pattern = 10

HW2 in

Lynx Plus

RE150 Special Transmitter

#2
#1

+12 Aux 3

RE150 Special Transmitter

Alarm
Output + 3

Resolution RE116-U Wireless Siren


Connection on
Honeywell Systems

Select siren supervision time (0-3)


[2] 30 seconds

RE116-U Siren Hardware Connections