Professional Documents
Culture Documents
Trig-Tek
OBSOLETE
500AT
Digital Analyzer
Key Features
5 Hz to 5 kHz frequency range
Linear/Log of Frequency
Linear/Log of Level
Frequency sweep
Manual tuning
Auto frequency tracking
Digital Hz/RPM counter
Digital level indicator
Product Information
The Trig-Tek 500AT is a tracking or
manually-tuned analyzer. It provides
analysis of an input signal by digitally
displaying the amplitude and frequency
of the individual components of that signal.
It provides phase information between the
REF and DATA signals. It provides analog
outputs, as well as the digital displays of
frequency and amplitude.
The 500AT provides the means to lock
on and track the reference input signal.
It provides the DC of Frequency and
frequency/speed indication. Frequency
readings are provided by means of a front
panel digital meter with 0.1 Hz resolution
or 10 RPM resolution.
The data input channel has a four-pole
Bessel Band-Pass Filter that permits
separating closely adjoined frequency
components. Level readings on the analyzer amplitude meter are provided with
0.1, 0.3, 1, 3, and 10 V Full Scale
(FS). It also provides 10, 30, 100,
300, or 1000 g FS.
In the Auto mode of operation, the analyzer will lock-on and automatically track
a changing frequency REF signal, ensuring
the component being tracked is always in
the center of the filter. The Sine and Cosine
outputs allow polar plots of the signal being
analyzed.
The Sweep mode provides a method
of setting the upper and lower frequency
limits as well as the sweep rate using the
front panel controls. The unit can sweep
between two frequencies in Linear or
Log mode.
In the Manual Tuning mode of operation,
the operator can manually tune the BandPass Filter to any frequency in the range.
Trig-Tek 500AT
Specifications
Note: The Astronics Test Systems policy is one
of continuous development and improvement.
Consequently, the equipment may vary in detail
from the description and specifications in this
publication.
Impedance
<50
Conformity
0.5 dB
Connector
BNC
Data Input
Frequency
5 Hz to 5 kHz
Level
10 V FS
Level
0 to 10 Vrms input guarded up to 150 Vrms
Accuracy
2% of indicated plus 0.2% of FS
Impedance
300 k
Impedance
<50 (5 mA)
Reference Input
Bandwidth
Bandpass: Three selectable (four pole
Bessel) filter bandwidths of 1.5, 5, or
15 Hz
Wideband: 10 kHz BW
Low Pass: Three times the tuning
frequency
Frequency
5 Hz to 5 kHz
Connector
BNC
Level
10 Vrms to 20 Vrms input guarded up to
150 Vrms
Connector
BNC
Impedance
300 k
Waveform
Sine, Square, Pulse (20 s or wider),
or Triangle
Common Mode Rejection
>40 dB at 60 Hz
Level
0 to 1 V
Connector
BNC
Connector
BNC
Accuracy
1% of reading 0.2% of FS
Level
10 Vs FS
Impedance
<50 (5 mA)
Offset (zero input, 100 Hz)
0 10 mV
Controls
Auto
Analyzer functions as a tracking filter
and will automatically acquire and track
the signal at the REF input
Manual
Analyzer must be manually tuned by
means of the Tuning control
Sweep
Analyzer will sweep upward at the rate
set by the Sweep Rate control; it will
start at the frequency set by the Manual
Tuning control
Sweep Hold switch
This switch, when in the Hold position,
will stop the sweep and hold at the
frequency selected
FS Range Switch
Connectors
BNC
OL (Overload)
Red light illuminates if input to filter
or output of filter is too high
Response Time
100 ms
Indicators
Conformity
0.5 dB
Quadrature
900.5 between Sine and Cosine
Impedance
<50 (5 mA)
Power
120 VAC, 50 to 400 Hz, 10 W
Power switch
Turns power On and Off
Accuracy
0.5% of indicated plus 0.1 % of FS
Interface
Impedance
<50
Connector
BNC
Level
5 V at 5,000 Hz
(Obsolete)
Trig-Tek 500AT
Specifications
continued
Calibration
Calib position of Range switch connects the DATA input to the calibrator
for setting the analyzer gain to10.00 g
FS, using the Calib Set control
RPM-Hz Switch
RPM
Sets the counter to indicate from
0 to 300,000 RPM
Hz
Sets the counter to indicate in Hz with
0.1 Hz resolution from 0 to 5000.0 Hz
Tuning
Ten-turn pot, which allows the operator
to manually tune the analyzer from
3 Hz to 5,000 Hz
(Obsolete)
Mechanical
Dimensions
19 W x 3.5 H x 12 D
(48.3 cm x 8.9 cm x 30.5 cm)
Weight
15 lbs (33 kg)
Current Set
A screwdriver adjustment to set the
current output when the mV/g input
is in use
Ordering Information
408300-001 : Trig-Tek 500AT (Obsolete)
Digital Analyzer
02-10-15 v2.0