You are on page 1of 8

Revisiones de Energa Renovable y Sostenible 47 (2015) 755-761

Listas de contenidos ofrecidos en ScienceDirect

Revisiones de la Energa Renovable y Sostenible


Pgina principal de la revista: www.elsevier.com/locate/rser

Contabilizacin de las emisiones de dixido de carbono de las


pequeas centrales hidroelctricas - Un estudio de caso en el suroeste
de China
Jing Zhang
a
Li
a

b
c
d

a,b,c

, Chuan-Yan Luo , Zachary Curtis , Shi-huai Deng

a,n

, Yang Wu , Yuan-wei

Provincial Key Laboratory of Agricultural Environmental Engineering, College of Environment, Sichuan Agricultural University, WenJiang, 625014 Sichuan, PR China
Colleges of Architecture and Environment, Sichuan University, Chengdu, 610065 Sichuan, PR China
The Department of Civil and Environmental Engineering, Michigan State University, East Lansing, 48823 MI, USA
Sichuan Jing Xing Environment Science and Technology Co., Ltd, Chengdu, 610081 Sichuan, PR China

Informacin del artculo

Resumen

Historia del artculo:

Pequeas centrales hidroelctricas, que son uno de los medios ms importantes para la produccin de energa limpia, tienen
un alto prestigio en el mercado de comercio de carbono. En este trabajo, se propone un mtodo para contabilizar la emisin de
dixido de carbono de las pequeas centrales hidroelctricas. Veintisis pequeas centrales hidroelctricas (PCH) en el
suroeste de China se eligen como un estudio de caso. Se encontraron los siguientes resultados: (1) la emisin de dixido de
carbono durante el perodo de construccin (COEC) por capacidad instalada oscil entre 0,01957 t/kW y 0,1926 t/kW, con su
valor medio 0,04592 t/kw; (2) la emisin de dixido de carbono durante el perodo de construccin se clasifica en dos grupos;
para cada grupo, existe una relacin recproca entre la capacidad instalada y la COEC anual por capacidad instalada, y (3) la
CEOo anual (emisin de dixido de carbono durante el perodo de operacin) disminuye con el aumento de la capacidad
instalada, los dos relacionados por una lnea recta . Especficamente, cuando los aumentos de capacidad instalados por las
emisiones de carbono 1 kW se reducen en un 16,33 t. COE o est directamente determinada por la energa hidroelctrica.
Adems, (4) la tendencia de las emisiones de dixido de carbono durante el ciclo de vida del sistema de PCH se determina por
COEo. El factor ms importante en la determinacin de la emisin de dixido de carbono de las PCH es asegurar la energa
hidrulica precisa de las PCH.

Recibido el 26 de septiembre de 2014


Recibida en forma revisada
6 de enero del ao 2015
Aceptado el 8 de marzo del ao 2015
Disponible en Internet el 30 de
marzo del ao 2015
Palabras clave:
Pequeas centrales
hidroelctricas
Emisin de dixido de carbono
Mecanismo de Desarrollo Limpio

& 2015 Elsevier Ltd. Todos los derechos reservados.

Contenido
1. Introduccin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 756
2. Mtodos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 756
2.1. Anlisis del balance de carbono para las PCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 756
2.2. Emisin del dixido de carbon en el period de construccin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 756
2.2.1. Dixido de carbono liberado por el material de construccin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 757
2.2.2. Dixido de carbono liberado por la ocupacin temporal de tierra. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 757
2.2.3. Dixido de carbono liberado por los constructores. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 757
2.3. Emisin del dixido de carbon en el periodo de operacin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 757
2.3.1. Reduccin de dixido de carbono por la energa hidroelctrica. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 757
2.3.2. Dixido de carbono liberado por la ocupacin permanente de la tierra. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 757
2.3.3. Dixido de carbono liberado por los operadores. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . 758
3. Datos y resultados . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 758
3.1. Datos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 758
3.1.1. Coeficiente de fuente de carbono y sumideros de carbono. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 758
3.1.2. Ubicacin y el sitio de estudio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 758
3.2. Resultados y anlisis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 758
3.2.1. Fuentes y sumideros de carbono de las PCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 758

*Autor correspondiente.
Correo electrnico: zcilly@126.com (J. Zhang), shdeng8888@163.com (S.-h. Deng).
http://dx.doi.org/10.1016/j.rser.2015.03.027 1364-0321/&
2015 Elsevier Ltd. Todos los derechos reservados.

756

J. Zhang et al. / Revisiones de Energa Renovable y Sostenible 47 (2015) 755761

3.2.2. Fuentes de carbono en el perodo de construccin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 759


3.2.3. Fuentes y sumideros de carbn en el periodo de operacin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 759
3.2.4. Emisin del dixido de carbono durante el ciclo de vida del sistema. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .760
4. Discusiones. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 760
5. Conclusiones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .760
Agradecimiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 761
Referencias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . 761

1. Introduccin
La energa desempea un papel importante en cada campo de las
actividades comerciales y humanos. Es un factor determinante del desarrollo
econmico y social tanto en los pases desarrollados y en desarrollo [1]. Las
demandas de energa aumentan rpidamente con el crecimiento econmico;
medio-tiempo, la degradacin ambiental y el cambio climtico se han
convertido en temas muy crticos [2]. Es bien sabido que el uso de los
recursos renovables (como la energa hidroelctrica, elica, biomasa, solar y
geotrmica) es la solucin ms eficaz para resolver los problemas ambientales
asociados con los combustibles fsiles.
Tambin es bien conocido que pequeas centrales hidroelctricas (PCH
aqu en adelante) han sido evaluados como candidatos para la reduccin de
emisiones de dixido de carbono [3-5]. Sin embargo, tambin existe la visin
crtica que los impactos biofsicos de las PCH pueden ser superiores a los de
las grandes centrales hidroelctricas, en particular con respecto al hbitat y el
cambio hidrolgico [6,7]. A pesar de las PCH emitira menos gases de efecto
invernadero (GEI), pueden causar varios problemas ambientales como la
eutrofizacin [8] y el deterioro ecolgico [9-11]. Explotando los recursos
hdricos es una estrategia de desarrollo de la energa en algunos pases en
desarrollo como China [12], la India [2] y Brasil [13].
Las PCH utilizan los recursos hidrolgicos renovables, que podran
reducir las emisiones de dixido de carbono directamente [14]. Por lo tanto, el
mercado de comercio de carbono estara dispuesto a ofrecer oportunidades de
financiacin o para construir PCH [15]. Antes de 2012, la nueva y reciente
construccin PCH podra reducir aproximadamente 3,15 millones de
toneladas equivalentes de dixido de carbono [15]. En general, la reduccin
de las emisiones de dixido de carbono por PCH depende de su generacin de
energa anual. La generacin de energa anual siempre depende de su
capacidad y el uso del tiempo instalado. Por lo tanto, el bruto anual de
emisin de dixido de carbono reducido en PCH se calcula por su capacidad
instalada, el uso de tiempo, y el factor de emisin de la electricidad [16].
China tiene una gran cantidad de ros de ms de 50.000 de los cuales
cubre un rea de la cuenca de ms de 100 km2, y 3886 de los cuales tiene un
potencial hidroelctrico de ms de 10 MW [17]. La generacin anual de
energa y el potencial hidroelctrico bruto terico son 6080 TWh / ao y 694
GW, respectivamente. Estos son los recursos de energa hidroelctrica ms
vale la pena en el sudoeste de China (que incluye Sichuan, Yunnan, Tbet, y
las provincias de Guizhou), por lo que es importante y representativo para
investigar la relacin entre la capacidad instalada y la emisin de dixido de
carbono de las PCH. Este enfoque podra ser beneficioso para calcular con
precisin la emisin de dixido de carbono de las PCH.
Este documento est estructurado de la siguiente manera. Seccin 2
propone un mtodo para calcular la emisin de dixido de carbono de PCH
(incluido el perodo de construccin y el perodo de operacin). Seccin 3
vistas generales de las fuentes de datos y, a continuacin, se presenta un
anlisis de la relacin entre las emisiones de dixido de carbono PCH 'y su
capacidad instalada. Seccin 4 se explica la relacin obtenida en la Seccin 3.
Por ltimo, se resumen el trabajo anterior y el trabajo futuro en la Seccin 5.

Para el perodo de construccin, las emisiones de dixido de carbono incluyen


el consumo de energa, tales como el uso de carbn, gasolina (incluido el
utilizado para el transporte de material de construccin), el gas y la
electricidad, el consumo de materiales de construccin tales como cemento,
acero, adorno y el poder equipos de generacin (incluyendo dnamo, turbinas,
etc.) -la ocupacin del suelo temporal, y sus actividades de vida de los
trabajadores de la construccin. Para el periodo de operacin, las emisiones de
dixido de carbono incluyen la ocupacin permanente de la tierra y
actividades de la vida de los trabajadores. Slo se considera el ciclo de vida de
las PCH, que suele ser de 30-50 aos [19]. Los procesos de emisin de
dixido de carbono PCH 'se muestran en la Fig. 1.
Hay tres fuentes potenciales de emisin para las PCH. En primer lugar, hay
actividades de vida humana tales como la construccin de presas, diques y
estaciones de energa -que son relevantes para las emisiones de dixido de
carbono generadas por las actividades intensivas en energa. En segundo
lugar, la tierra juega dos papeles en la emisin de dixido de carbono. Una de
ellas es la biomasa en descomposicin en la tierra inundada producir
emisiones de dixido de carbono; esta parte casi podra ser ignorado como
tierra inundada asociado con las PCH es a menudo muy pequeos. La otra
caracterstica de los terrenos importante las emisiones de CO 2 es la capacidad
de secuestro de carbono mediante la fotosntesis que ocurre en las plantas. Si
esta tierra es industrializada, esta capacidad de secuestro de la tierra
desaparece. En tercer lugar, se deben considerar los sustitutos de la energa
hidroelctrica. Si la demanda de energa total es un valor constante, la energa
hidroelctrica podra reducir el requerimiento de energa trmica.
2.2. Emisin de dixido de carbono en el perodo de construccin
El dixido de carbono liberado durante el perodo de construccin
proviene principalmente del consumo de materias primas (incluyendo el
consumo de energa), la ocupacin del suelo y actividades de la vida de los
constructores. El dixido de carbono que se libera en el perodo de
construccin (corto como COEC), se define como sigue:
COEC = COEBM + COETL + COEW
donde COEC es el dixido de carbono que se libera durante el perodo de
construccin; COEBM es el dixido de carbono que se libera al proporcionar
materiales de construccin; COETL es el dixido de carbono que se libera por
la ocupacin temporal de tierra; COEw es el dixido de carbono que se libera

2. Mtodos
2.1. Anlisis del balance de carbono de las PCH
La emisin de dixido de carbono de los buques que se organiz en dos
periodos: un periodo de construccin y un perodo de operacin [18].

Fig. 1. Diagrama de anlisis del balance de carbono de las PCH.

mediante actividades de la vida de los constructores. Las unidades de COE C,


COEBM, COETL, y COEw son la tonelada.
1.1.1. El dixido de carbono liberado por el material de construccin

2.3. La emisin de dixido de carbono en el perodo operativo

No slo la cantidad, sino tambin cmo los materiales de construccin ricos en


carbono determinan la COEBM. Nuestros NDS investigacin fi que los
principales materiales de construccin de pequea central hidroelctrica son el
cemento, el acero, explosivos, madera, petrleo diesel y equipo de generacin de
energa. El dixido de carbono liberado por la unidad de la materia prima es
diferente. Por lo tanto,
se define de la siguiente manera:

El dixido de carbono liberado durante el perodo de operacin est


determinado principalmente por la ocupacin permanente de la tierra y
actividades de la vida de los operadores. La energa hidrulica, como el
sustituto de la energa trmica, podra reducir indirectamente la emisin de
dixido de carbono. El dixido de carbono liberado en el periodo de operacin
se define por:

Donde
es la liberacin de dixido de carbono por la construccin de
generacin o consumo de material, con unidades de toneladas / toneladas; BMi
es la cantidad de material de construccin se consume, con unidades de
toneladas; y subndice denota los diferentes materiales de construccin,
incluyendo cemento, acero, explosivo, madera, petrleo diesel y equipo de
generacin de energa.

Donde

es el dixido de carbono liberado en el periodo de operacin;


es la emisin de dixido de carbono que libera una trmica de la central
elctrica cuando se genera la potencia equivalente como sera generada en
centrales hidroelctricas; COEPL es la cantidad de dixido de carbono que la
ocupacin permanente de la tierra absorbe o libera; y COEO es el dixido de
carbono liberado por la actividad de la vida de los trabajadores. Las unidades de
COEO, COEHR, COEPL, y COEO toneladas.

1.1.2. El dixido de carbono liberado por la ocupacin temporal de


tierra

2.3.1.
La reduccin de dixido de carbono por la energa
hidroelctrica

La ocupacin de la tierra incluye la ocupacin temporal de tierra y la ocupacin


permanente de la tierra. La ocupacin temporal de tierra se utiliza generalmente
para los sitios de trabajo, la construccin temporal de carreteras, y un dragado
abandonada sitios de disposicin de materiales. En el caso de ocupacin
temporal de tierra, la vegetacin ser restaurado despus de realizadas todas las
construcciones. En general, el perodo de construccin de SHPs es no ms de
cinco aos. Las plantas de la ocupacin temporal de tierra perderan (o que
debilitan) su capacidad para absorber el dixido de carbono antes de la
restauracin de la vegetacin. El tipo de vegetacin, el tiempo empleado en la
restauracin de la vegetacin, y el rea de ocupacin de tierras codetermines el
dixido de carbono absorbido o liberado. Como SHPs a menudo se encuentran
en las altas regiones montaosas, los tipos de vegetacin ms o menos se
determinan por el tipo de terreno. Por lo tanto, COETL se define de la siguiente
manera:

La reduccin de las emisiones de dixido de carbono, cuando la energa


hidroelctrica se sustituye por energa trmica, est determinada por la
intensidad de carbono de la energa trmica y la energa hidroelctrica. As, la
reduccin de dixido de carbono se puede expresar como sigue:

donde T es el tiempo, en aos, de ocupacin temporal de tierra (en esta


investigacin, el valor es de 5 ao);
es el dixido de carbono que la tierra
absorbe o libera, con unidades de kg / m 2 ao; A2i es el rea de ocupacin
2
temporal de tierra, en m ; y el subndice i es el tipo de terreno, incluyendo las
tierras forestales, la tierra cubierta de hierba, tierras de cultivo, suelo urbano, y
el desierto.
1.1.3. El dixido de carbono liberado por los constructores
El dixido de carbono liberado por los constructores es a menudo determinado
por el tiempo de construccin, tipo de trabajo, y la intensidad de carbono de las
personas '. Por lo tanto, el dixido de carbono emitido por las actividades de la
vida de los constructores se puede expresar de la siguiente manera:
Donde BW es el nmero de constructores y PCI es la intensidad de carbono de
la persona, su unidad es toneladas por da y persona, respectivamente.
A medida que la industria es arcaico en el sudoeste de China, los materiales de
construccin de las SHPs, como el cemento, el acero, e incluso material
decorativo, se obtienen generalmente de Ya'an o Chengdu, que se encuentra a
500 km de distancia de los sitios de construccin. Otros materiales de
construccin tales como arena, piedra y madera podran ser localmente
disponibles por los constructores. SHPs normalmente se encuentran slo en las
montaas, donde los suelos estn cubiertos por la hierba, las espinas, arbustos y
rboles. Mediante la incorporacin de los efectos de la obtencin de materiales
de construccin para SHPs, es posible utilizar el mtodo anteriormente
mencionado para investigar la emisin de dixido de carbono durante el

Donde CITP es la intensidad de carbono de la generacin de energa trmica en


unidades de toneladas por kilovatio-hora y l es la generacin de energa
hidroelctrica en unidades de kilovatios-hora (kW h son unidades de energa =
potencia * Tiempo)
En China, la energa procedente de combustibles fsiles constituye ms del 80
por ciento de la generacin elctrica de China por un perodo prolongado de
tiempo. Casi la totalidad de las centrales elctricas alimentadas con combustibles
fsiles utilizar carbn como combustible. El contenido de carbono del carbn y la
eficiencia de la generacin de electricidad para cada estacin de energa de
combustible fsil es diferente, por lo que es difcil estimar con precisin las
emisiones de dixido de carbono por unidad elctrica. De acuerdo con "principios
generales para el clculo del consumo total de energa de la produccin" y "las
directrices de la lista de gases de efecto invernadero para la provincia", las
emisiones medias de dixido de carbono por unidad elctrica en el centro de
China (que incluye el sitio de estudio) es 0,801 kg / kW h [ 20].
2.3.2. El dixido de carbono liberado por la ocupacin permanente de la
tierra.
Las emisiones de dixido de carbono de las presas hidroelctricas fueron a
menudo como inexistente por la industria de la energa hidroelctrica, y se han
ignorado en gran medida en los clculos globales de las emisiones derivadas del
cambio de uso de la tierra antes del siglo 20 [21]. En algunos casos, grandes
extensiones de tierra fueron inundado cuando embalses unidades se ocuparon
de manera que algunas centrales hidroelctricas con grandes depsitos podran
producir ms emisiones de carbono que las plantas trmicas. Por lo tanto, la
ocupacin permanente de la tierra sera significativamente influir en la emisin
de dixido de carbono.
Table 1

El coeficiente de fuentes de carbono y sumideros de carbono.


Types

Item

Carbon
source

Carbo
n sink

Fuel energy [22]

Gasoline (t/t)
Diesel oil (t/t)
2
Forest land (kg/(m a))
2
Grassy (kg/(m a))
2
Farmland (kg/(m a))
2
Urban land (kg/(m
a))
2
Desert (kg/(m a))

3.10464
3.20931

3.689
1.276
2.222

Cement [28,29](t/t)

0.75

Land
[23,24]

perodo de construccin.
Construction
material

Wood [25]
(t/t)
1.75

Steel
[26,27](t/t)
2.16

use

0.609
0.055

Others
(t/a)

The person's life activity


[30
]

0.289

Table 2
Veintisis SHPs en el sudoeste de China.
Number

Hydropower plants' name

Location

Longitude

Latitude

Elevation (m)

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Na Zha ka
You La Xi
Da Yan Gou
Jiang Da
Yong Xi Gou1
Yong Xi Guo2
Jin Tou Zhai
Tou Dao Qiao
Cuo Ri Gou
Gua Zi Gou
Ga Ri
Xin Ni
Ran Wu Gou
Se Ge
Ma Xiong Gou
Mu Ru
Da Cao Ba
Zhe Luo
Xiang Shui Gou1
Xiang Shui Gou2
Ku Yi Rong
Mo Xi
Wan Dong He
Hua Jiao Ping
La Ma Si
Jie Wa

Xin Long County


Xin Long County
Dan Ba County
Dan Ba County
Dan Ba County
Dan Ba County
Dan Ba County
Dan Ba County
Dan Ba County
Dan Ba County
Gan Luo County
Gan Luo County
Xiang Cheng County
Xiang Cheng County
Xiang Cheng County
Dao Fu County
King Ding County
King Ding County
King Ding County
King Ding County
King Ding County
Lu Ding County
Lu Ding County
Jiu Long County
Jiu Long County
Mei Gu County

301340 41.67

1001180 8.53

301300 54.47
30130 23.69
301470 13.27
301410 17.75
301390 26.93
31120 58.14
31150 5.04
301470 39.95
301480 15.57
281550 51.24
29130 58.76
21470 7.43
281450 28.49
29190 57.98
301480 39.14
301310 50.94
301320 7.88
301390 26.69
301410 48.81
291250 49.13
291360 19.44
291340 50.44
281550 24.24
281410 45.93
281450 51.66

1001250 18.92
1011420 27.16
1011560 39.16
1011450 7.84
1011480 8.83
1011380 14.45
1011400 6.57
1011450 44
1011460 46.33
1021430 42.94
1021400 37.87
991490 24.83
991480 2.67
991550 22.82
101170 33.11
1011560 15.07
102100 35.04
1011480 8.30
1011450 3.24
1011180 19.20
1021100 33.08
1021110 4.28
1011500 14.74
1011400 26.08
1031150 41.24

2965
2951
2821
1899
2618
3246
2488
2721
2190
2156
1107
1300
2614
2553
3029
2896
3115
2135
3242
2617
2855
1143
1225
3090
2265
1573

Del mismo modo, la ocupacin temporal de tierra, el sumidero de carbono


de ocupacin permanente de la tierra est determinado por el tiempo de
ocupacin, el tipo de suelo y la extensin del rea de la cobertura de la
tierra. Por lo tanto, los sumideros de carbono de la ocupacin permanente
de la tierra se expresan como sigue:

donde
es el momento de la ocupacin permanente de la tierra, con
unidades de aos (en este estudio, Ti es de 40 aos); 2i est absorbiendo
carbono intensidad de la tierra, con unidades de kg / m 2ao; A1 es el rea
de ocupacin permanente de la tierra, con unidades de m ; y el subndice i
es el tipo de tierra permanente.
2.3.2. El dixido de carbono liberado por los operadores
El dixido de carbono liberado por los operadores es la misma que la
liberada por los constructores. Se aproxima por el momento, el nmero de
trabajadores, y la intensidad de carbono de las personas '. Por lo tanto, el
dixido de carbono liberado por los operadores se puede expresar como
sigue:
donde el NO es el nmero de operadores y PCI es la intensidad de
carbono de las personas ', con unidades de tonelada por da y persona,
respectivamente.
3. Los datos y resultados
3.1. Los datos
3.1.1. El coeficiente de fuente de carbono y sumideros de carbono
El consumo de la energa de combustibles, el consumo de materiales de
construccin, actividades de la vida de la persona, y el explosivo se
consideran como fuentes de carbono. La vegetacin es considerada como
sumidero de carbono. En general, el tipo de ocupacin del suelo determina los
tipos de vegetacin en una zona montaosa. Por lo tanto, se cree que la edad
de la vegetacin y tipos de ocupacin del suelo determinan la capacidad de un
rea de tierra para absorber el dixido de carbono. En esta investigacin, slo
el tipo de uso de la tierra se considera. Por lo tanto, los coeficientes de
sumideros de carbono para tierras forestales cubiertas de hierba, tierras de
cultivo, el suelo urbano y el desierto se obtienen a partir de investigaciones
previas. Sobre la base de esta investigacin previa, los coeficientes de las
fuentes de carbono y sumideros de carbono se muestran en la Tabla 1.

Tabla 3
El resultado del anlisis de regresin.
c
o
Parmetros a o a
Periodo
(t/kW)
Periodo de
Construccin
Periodo de
Operacin

0.0179
0.0029
16.33

Parmetros b o

F-test R

b (t)
105.35
634.70
1395.44

110.31 0.8874
98.24 0.9247
717.95 0.9677

3.1.2. La ubicacin y el sitio de estudio


Veintisis SHPs en el sudoeste de China son elegidos para el estudio de caso
(que se muestra en la Tabla 2). Estos SHPs se encuentran en la regin de
origen del ro Yangts y el ro Amarillo. El rea de la cuenca es de 146.100
km2, representa el 8,5% de la cuenca del ro Yangtze, con 41.190.000 kW
potencial hidroelctrico. Por lo tanto, es muy significativo fi la
contabilizacin de las emisiones de dixido de carbono de las SHPs. Los
parmetros de las SHPs se obtienen principalmente de sus datos de diseo e
informacin de evaluacin ambiental.
3.2. Los resultados y anlisis
3.2.1. fuentes de carbn y sumideros de las SHPs
De acuerdo con la teora estadstica, las muestras para los que la diferencia
entre sus valores y el promedio de valor de las muestras es mayor que tres
veces la varianza de las muestras se consideran como valores atpicos. Por lo
tanto, los valores extremos se pueden encontrar de acuerdo con el valor medio
y la varianza del conjunto de la muestra. El resultado de las fuentes y
sumideros de carbono de las SHPs se muestra en la Tabla 3.
Basado en el mtodo propuesto en la parte 2, se obtuvieron las emisiones de
dixido de carbono por la capacidad instalada en cada uno de los diferentes
perodos (perodo de construccin y el perodo de operacin). Como la fig. 2
muestra, la COEc por rango de potencia instalada es de entre 0,01957 t / kW y
0,01926 t / kW, con su valor promedio es de 0,04593 t / kW. La varianza de
COEc por capacidad instalada es de 0,03815. Por lo tanto, el valor de COE c
por capacidad instalada normalmente debe oscilar entre 0 t / kW y 0,1604 t /
kW. En estos 26 las SHPs, slo uno SHP se consider como un valor atpico.

Fig.2 Capacidad instalada de COEc por ao


Mientras tanto, COEo anual por capacidad instalada oscil entre 0,5607 t / kw y
0,3562 t / kw. El COEo medio anual por capacidad instalada y sus varianzas son
0,4129 t / kw y 0,04404 t / kW, respectivamente. Por lo tanto, el rango normal
debe estar entre 0,2808 t / kw y 0,5450 t / kw. Los valores promedio y la
varianza de COE (igual a COEc ms COEo) son 0,3670 t / kw y 0,04134 t / kW,
respectivamente. Su rango normal debe estar entre 0,2430 t / kw y 0,4910 t / kw.
El valor mximo es 0,2788, que es ms grande que su rango normal. De manera
similar a COEc, tanto COEo y COE tienen valores atpicos.
3.2.2. Las fuentes de carbono en el perodo de construccin
El dixido de carbono liberado en el perodo de construccin es producido
por el consumo de los materiales de construccin, consumo de combustible, y
por actividades de la vida de los constructores. En general, material de
construccin, la energa del combustible, y los constructores estn determinados
por el trabajo de ingeniera de la SHP particular. El diseo, la escala y
ubicaciones geogrficas hara influir en el trabajo de ingeniera. Todas las
las SHPs en la muestra estn situados en el sudoeste de China, con su atraso
econmico y la mala infraestructura de comunicacin. Los diseos de las SHPs
son casi similares. La principal diferencia de las SHPs es en sus escalas. Por lo
tanto, debe haber una relacin entre el forro COEc y la capacidad instalada de
las SHPs, como el que la Ec. (9) muestra, o equivalentemente existe una relacin
recproca entre COEc por capacidad instalada y su capacidad instalada se
muestra en la ecuacin. (10):

donde ac es el coeficiente de la capacidad instalada de las SHPs, con unidades de


toneladas
/ kW; ICi es la capacidad instalada de las SHPs, con unidades de kW;
bc es una constante, con unidades de toneladas; COE ic es la emisin de dixido
de carbono en el perodo de construccin de las SHPs, con unidades de
toneladas; y el subndice i es el nmero de las SHPs.
c
De acuerdo con la Ec. (9), la relacin entre COE
y la capacidad instalada debe
ser una lnea recta y la relacin entre COE c por la capacidad instalada y la
capacidad instalada debe ser una lnea de reciprocidad. Este resultado es
consistente con el anlisis de Varun con respecto a la estimacin de emisiones
del ciclo de vida de las SHPs. Como las caractersticas de los 26 las SHPs son
diferentes, son clasificarse en dos grupos genricos (es decir, la lnea azul y la

Fig.3 La relacin entre COEC por la capacidad instalada y la


capacidad instalada. (Para la interpretacin de las referencias de color
en esta figura, se remite al lector a la versin web de este artculo).
de acuerdo con los parmetros de la ecuacin. (10). Tenga en cuenta
que cuanto menor sea la capacidad instalada, la mayor diferencia
entre los dos grupos. El ac y bc parmetros de los dos grupos estn en
un nivel de significativo de 0.025. De acuerdo con la prueba F, la
ecuacin. (10) (o la Ec. (9)) est en un nivel significativo de 0,025
basado en ambos grupos. Los coeficientes de correlacin
correspondientes (R2) son 0,9247 y 0,8874. Por lo tanto, la ecuacin.
(10) o la ecuacin. (9) podra ser utilizado para estimar COEc, basado
en la capacidad instalada de las SHPs como la variable de modelo.
3.2.3. Las fuentes y sumideros de carbono en el periodo de operacin
Las fuentes y sumideros de carbono en el periodo de operacin
incluyen la actividad de la vida de los operadores y de ocupacin
permanente de la tierra. La energa hidrulica, que se cree de la
energa como limpio, reducira la necesidad de generadores disel.
As, sera indirectamente
reducir las emisiones de dixido de carbono mediante la reduccin de
la carga de trabajo para los generadores disel.

lnea verde como se muestra en la Fig. 3)

De acuerdo con la teora de CDM (Mecanismo de Desarrollo Limpio), la


reduccin de las emisiones de dixido de carbono es proporcional a la
generacin de electricidad de las SHPs. A partir de los resultados de la parte
3.2.1, COEo est determinada por la energa hidroelctrica anual, que
est estrechamente relacionada con la capacidad instalada y el uso del tiempo de
las SHPs. El tiempo de uso de las SHPs se encuentra en las regiones de montaa

es casi la misma. Por lo tanto, la ecuacin. (11) se introduce para expresar la


emisin de dixido de carbono en el periodo de operacin,

esta investigacin, los 26 SHPs se encuentran a una altura diferente.


En general, cuanto mayor sea la altitud, mayor ser el volumen de
materiales de construccin SHP. Por lo tanto, dos grupos se obtienen
cuando se discute la relacin entre COEC y capacidad instalada (la
verdadera razn es que a medida que la altitud es diferente, el agua
de transporte de tneles por capacidad instalada del primer grupo es
ms larga que la del segundo grupo). Los SHPs del primer grupo se
encuentran en una altitud ms alta que el segundo grupo. Las
condiciones de trfico de SHPs del primer grupo son mucho ms
pobre que la del segundo grupo de SHPs. Por lo tanto, estos SHPs
requieren ms recursos (materiales de construccin, como el
cemento, gasolina, y disel) para mejorar las condiciones del trfico.
Para el primer grupo de SHPs, la COEC anual aumentara 0,0179 t
cuando se aade 1 kW de potencia instalada. Mientras que para el
segundo grupo de SHPs, ese valor es solamente 0,0029 t.
5. Conclusiones

Fig.4 La relacin entre el COE y la capacidad instalada de SHPs en el periodo


de operacin.
donde ao es el coeficiente de la capacidad instalada de las SHPs, con unidades de
o
toneladas / kW; b es una constante, con unidades de toneladas; COEoi es la
emisin de dixido de carbono en el perodo de funcionamiento de las SHPs, con
unidades de toneladas; y i es el nmero de las SHPs.
De acuerdo con la Ec. (11), la relacin de la capacidad COE c-instalado es lineal
como se muestra en la Fig. 4. Por lo tanto, COE c aumentara proporcionalmente
con el aumento de la capacidad instalada de las SHPs. Los parmetros de a o y bo
estn en un nivel significativo de 0.025. De acuerdo con la prueba F, la ecuacin.
(11) est en un nivel significativo de 0.025. El correspondiente coeficiente de
correlacin (R2) es 0.9676. Por lo tanto, la ecuacin. (11) podra ser utilizado
para estimar COEo, basado en la capacidad instalada de las SHPs como la
variable de modelo.

Se calcularon las emisiones de dixido de carbono de 26 pequeas


centrales hidroelctricas en el sudoeste de China. A partir de los
resultados de la regresin y la discusin, la siguiente conclusin se
puede obtener:
(1) El COEC por capacidad instalada oscila entre 0,01957 t / kW y
0,1926 t / kW, con un valor promedio de 0,04592 t / kW. Adems de
una pequea central hidroelctrica, no hay valores atpicos. Mientras
tanto, tanto COEO y COE tienen valores atpicos.
(2) La emisin anual de dixido de carbono en el perodo de
construccin se clasifica en dos grupos. Para cada grupo, existe una
relacin recproca entre la capacidad instalada y la emisin anual de
dixido de carbono por capacidad instalada.

3.2.4. las emisiones de dixido de carbono del ciclo de vida durante el sistema
Est claro que hay una gran brecha entre COE C y COEO. COEC vara con la
capacidad instalada de las PCH-7457 entre ty 35.420 t. Mientras tanto, COE O
oscila entre 59.020 t y 406, 700 t. El valor absoluto de COE O es mucho mayor
que la de COEC. Para resumir, la emisin de dixido de carbono es negativo en
el ciclo de vida de las PCH; PCH tienen la capacidad de reducir la emisin de
dixido de carbono. La tendencia de la emisin de dixido de carbono en el ciclo
de vida de PCH se determina por COEO. Mientras tanto, COE C determina la
fluctuacin de la emisin de dixido de carbono en el ciclo de vida de SHPs.
Con base en el anlisis anterior, la emisin anual de dixido de carbono en el
ciclo de vida de las SHPs est directamente determinada por la capacidad
instalada y las horas de uso anuales. En esta investigacin, todas las SHPs se
encuentran en las regiones montaosas de manera que las horas de uso anuales
son casi los mismos. Por lo tanto, la emisin anual de dixido de carbono en el
ciclo de vida de las SHPs est determinada principalmente por la capacidad
instalada. Los descensos anuales de las emisiones de dixido de carbono de
872,6 t de 9.699,0 t con un aumento de la capacidad instalada del SHPs. Cuando
las capacidades instaladas aumento de 1 kW, la emisin anual de dixido de
carbono podra disminuir 0,0179 t.
4. Discusiones

(3)

El COEO anual disminuye con el aumento de la capacidad


instalada de forma lineal. Cuando aumenta la capacidad instalada de
1 kW, con ello 16.33 toneladas de dixido de carbono se reduciran.
COEO est directamente determinada por la energa hidroelctrica.
(4) La tendencia de las emisiones de dixido de carbono en el ciclo
de vida de las PCH se determina por COEO. La obra ms importante
de lo que representa la emisin de dixido de carbono de las SHPs es
asegurar la energa hidrulica precisa de las SHPs.
Agradecimiento
Los trabajos estn soportados por el Consejo de Becas de China,
20130620067. Exencin de responsabilidad num-Bered: Este
informe se prepar como una relacin de trabajo patrocinado por el
Consejo de Becas de China. Ni el gobierno chino ni ningn
organismo de la misma, ni ninguno de sus empleados, otorgan
ninguna garanta, expresa o implcita, ni asume ninguna
responsabilidad legal o responsabilidad por la exactitud, integridad o
utilidad de cualquier informacin, aparato, producto o proceso
divulgado, o representa que su uso no infringira los derechos de
propiedad privada.

Las prdidas resistivas de electricidad en las lneas de transmisin, lo que


reducira significativamente la energa hidroelctrica son ignoradas en nuestra
investigacin. Las prdidas resistivas de electricidad en las lneas de transmisin
pueden ser separadas como prdidas tcnicas y prdidas no tcnico. El primero
depende directamente de las caractersticas de red y el modo de funcionamiento.
Como la mayora de las PCH se encuentran en zonas remotas Mountai-nous, las
largas distancias de las lneas de transmisin conduciran como prdidas
resistivas. Por lo tanto, el resultado obtenido sera ms alto que su valor preciso.
SHPs se definen como presas de tipo corrida de rio con pequeos
Referencias
embalses. Se trata principalmente de una pequea presa de hormign,
[1] Zhang J, Deng SH, Shen F, Yang XY, Liu GD, Guo H, et al. Modeling the relationship
una tubera de carga, una tubera de presin y una central elctrica.
between energy consumption and economy development in China. Energy 2011;36(7):4227
La cada total es el factor determinante para los tipos de centrales
34.
hidroelctricas de pasada ro. Por lo tanto, la casi totalidad de las [2] Nautiyal H, Singal SK, Vaun AS. Small hydropower for sustainable energy development in
India. Renew Sustain Energy Rev 2011;15(4):20217.
SHPs se localizan en las regiones montaosas remotas donde tanto la
infraestructura de transporte y la industria estn sin desarrollar. En

[3] Ghosh D, Shukla PR, Garg A, Ramana PV. Renewable energy technologies for the Indian
power sector: mitigation potential and operational strategies. Renew Sustain Energy Rev
2002;6(6):481512.
[4] Tanwar N. Clean development mechanism and off-grid small-scale hydro- power projects:
evaluation of additionally. Energy Policy 2007;35(1):71421.
[5] Timilsina GR, Shretha RM. General equilibrium effects of a supply side GHG mitigation
option under the clean development mechanism. J Environ Manag 2006;80(4):32741.
[6] Premalatha M, Tabassum-Abbasi, Abbasi T, Abbasi SA. A critical view on the ecofriendliness of small hydroelectric installations. Sci Total Environ 2014;481(15):63843.
[7] Melly MK, Desiree DT. Cumulative biophysical impact of small and large hydropower
development in Nu River, China. Water Resour Res 2013; 49(6):310418.
[8] Devault DA, Merlina G, Lim P, Probst JL, Pineli E. Multi-residues analysis of pre- emergence
herbicides in fluvial sediments: application to the mid-Garonne river. J Environ Monit
2007;9(9):100917.
[9] Li XJ, Zhang J, Xu LY. An evaluation of ecological losses from hydropower development in
Tibet. Ecol Eng 2015;76(1):17885.
[10] Zhang J, Xu LY. Embodied carbon budget accounting system for calculating carbon footprint
of
large
hydropower
project.
J
Clean
Prod
2013.
http://dx.doi.
org/10.1016/j.jclepro.2013.10.060.
[11] Huang HL, Zheng Y. Present situation and future prospect of hydropower in China. Renew
Sustain Energy Rev 2009;13(6):16526.
[12] Barros RM, Filho GLT. Small hydropower and carbon credits revenue for an SHP project in
national isolated and interconnected systems in Brazil. Renew Energy 2012;48(1):2734.
[13] Purohit P. Small hydro power projects under clean development mechanism in India: a
preliminary assessment. Energy Policy 2008;36(6):200015.
[14] Zhou S, Zhang X, Liu J. The trend of small hydropower development in China. Renew
Energy 2009;34(4):107883.
[15] Zhang J, Liu GD, Deng SH, Liu L, Guo H, Huang LL, et al. Simulation of the monthly
hydroelectricity generation in China based on logistic model. Energy Sour Part B: Econ Plan
Policy 2013;9(4):38390.
[16] Zhou SC, Tian ZW. China's hydro resources are the richest in the world- Summary of the
national countercheck of hydro resources. China Three Gorges Construct 2005;6:6873.
[17] Gagnon L, Camille B, Uchiyama Y. Life-cycle assessment of electricity genera- tion options:
the status of research in year 2001. Energy Policy 2002; 30(14):126778.
[18] Corinne GL, Robert D, Georges K, Sandrine R, Philippe G. Long-term green- house gas
emissions from hydroelectric reservoirs in tropical forest regions. Glob Biogeochem Cycles
1999;13(2):50317.
[19] OECD, IEA. CO2 emissions from fuel combustion highlights. 2013 EditionIn-ternational
Energy
Agency;
2013
France,
http://www.iea.org/publications/free
publications/publication/co2emissionsfromfuelcombustionhighlights2013.pdf.
[20]
[21] Philip MF. Greenhouse gas emissions from a hydroelectric reservoir (Brazil's Tucurui Dam)
and the energy policy implications. Water Air Soil Pollut 2002;133(1):6996.
[22]
[23] IPCC. Climate change 2007: synthesis report. In: Pachauri RK, Reisinger A, editors. IPCC
fourth assessment report (AR4): contribution of working groups I, II and III to the fourth
assessment report of the intergovernmental panel on climate change, IPCC, Geneva,
Switzerland. 2007, p. 104.
[24]
[25] Zhao M, Kong ZH, Escohede FJ. Impacts of urban forests on offsetting use in HagZhou,
China. J Environ Manag 2010;91(4):80713.
[26] Ling X, Zhao XG, Luan JW. Research on carbon cycle in Gansu province during 20002009.
Areal Res Dev 2012;31(5):12230.
[27] Nilesh T, Christina LS, Francisco JE, Alicia L. Tree biomass, wood waste yield, and carbon
storage changes in an urban forest. Landsc Urban Plan 2014;27:1827.
[28]
[29] Price L, Sinton J, Worrell E, Phylipsen D, Xiulian H, Ji L. Energy use and carbon dioxide
emissions from steel production in China. Energy 2002;27(5):42946.
[30] Sun WQ, Cai JJ, Mao HJ, Guan DJ. Change in carbon dioxide (CO2) emissions from energy
use in China's iron and steel industry. J Iron Steel Res Int 2011; 18(6):316.
[31]
[32] Shi YR, Chen LL, Liu Z, Yan JM, Hu J. Analysis on the carbon emission reduction potential
in the cement industry in terms of technology diffusion and structural adjustment: a case
study of Chongqing. Energy Proced 2012;16:21130.
[33]
[34] Rehan R, Nehdi M. Carbon dioxide emissions and climate change: policy implications for the
cement industry. Environ Sci Policy 2005:10514.
[35] Whitmarsh L, Seyfang G, Saffron O. Public engagement with carbon and climate change: to
what extent is the public carbon capable? Glob Environ Chang 2011;21(1):5665.
[36]
[37] Bao WH, Sun L, Chang RQ. Discussion about that gas pollutant influences on the
environment which commercial explosion produces. Sci Technol Baotou Steel (Group) Corp
2006;32:1068.
[14] Huang XF, Dai HC, Fang GH, Tang M. Management system study on large hydropower
station reservoirs groups in upper Yangtze river. Proced Environ Sci 2011;10:222632.
[15] Serfling R, Wang SS. General foundations for studying masking and swamping
robustness of outlier identifiers. Stat Methodol 2014;20:7990.
[16] Ha JY, Seok S, Lee JS. Robust outlier detection using the instability factor. KnowlBased Syst 2014;63:1523.

[17] Zhang J, Liu GD, Guo H, Liu L, Deng SH. A theoretical basis for the relationship
between the industrial pollutant generation, abatement, emission and econ- omy.
Clean Technol Environ Policy 2013;15(4):70711.
[18] Zhang J, Wang CM, Liu L, Guo H, Liu GD, Li YW, et al. Investigation of carbon
dioxide emission in China by primary component analysis. Sci Total Environ
2014;472(15):23947.
[19] Varun, Prakash Ravi, Bhat IK. Life cycle greenhouse gas emissions estimation for
small hydropower schemes in India. Energy 2012;44(1):498508.
[20] Hondo H. Life cycle GHG emission analysis of power generation systems: Japanese
case. Energy 2005;30(11):204256.

You might also like