Professional Documents
Culture Documents
www.NOV.com/GrantPrideco
(in) 4.000
(in) 0.330
S-135
Controlled Length
TurboTorque 390
(in) 4.875
(in) 2.688
(in) 12
(in) 15
Drill-Pipe Length
29,700
Operational
Max Tension
Torque (ft-lbs)
(lbs)
Minimum MUT
21,200
Tension Only
Combined Loading
Tension Only
Combined Loading
(psi) 130,000
(in)
IU
4.188
Controlled Length
(without Coating)
80 % Inspection Class
Recommended
MUT
3/32 Raised
Best Estimates
(ft-lbs)
(in)
14.00
44.5
Applied Make-up
Torque
(ft)
0
27,800
403,500
212,500
0
18,300
403,500
334,900
Fluid Displacement
Fluid Displacement
Fluid Capacity
Fluid Capacity
Drift Size
15.56
0.24
(Bbls/ft) 0.0057
(gal/ft) 0.44
(Bbls/ft) 0.0104
(in) 2.563
Nominal
(with Coating)
(least accurate)
14.96
0.23
0.0054
0.45
0.0106
(lbs/ft)
(gal/ft)
0.43
0.0103
TurboTorque 390
Connection Performance
4.875 (in)
Applied Make-up
Tension at Shoulder
Torque
Separation
(ft-lbs)
29,700
21,200
Tensile Limited
685,700
(lbs)
OD X
2.688 (in)
Tension at Connection
Yield
(lbs)
412,600
686,700
(ft-lbs)
(lbs)
SmoothEdge Height
3/32 Raised
5.062
(lbs) 631,200
(in)
130,000
(psi)
(in) 4.832
(in)
4.577
42,500
686,700
Note: Recommended make-up torque is the maximum make-up torque that should be applied.
Note: To maximize connection operational tensile, a MUT (T4) = 21,200 (ft-lbs) should be applied.
ID
4.875
470,100
4.577
226,500
Nominal
Assumed Slip Length
Transverse Load Factor (K)
(lbs) 431,800
2.6
4 (in) OD
80 % Inspection Class
341,300
Nominal
513,600
(ft-lbs) 41,900
1.01
(ft-lbs) 33,500
(psi) 19,491
(psi) 20,141
(in) 4.000
(in) 0.330
(in) 3.340
(in^2) 3.805
(in^2) 12.566
(in^2) 8.762
(in^3) 3.229
(in^3) 6.458
(lbs)
S-135 )
Note: Slip Crushing: Slip crushing load is calculated with the Spiri-Reinhold equation from Why Does Drill Pipe
Fail in the Slip Area World Oil, 1959 for the slip length and transverse load factor shown and is for reference
only. Slip crushing is dependent on the slip design and condition, coefficient of friction, loading conditions, time in
slips, drill pipe OD and wall variation, and other factors. Consult with the slip manufacturer for additional
information.
(in) 16.5
(in)
Note: Elevator capacity based on assumed Elevator Bore, no wear factor, and contact stress of 110,100psi.
Note: A raised elevator OD increases elevator capacity without affecting make-up torque.
(in) 4.281
4.691
317,900
5.062
4 (in) OD
80 % Inspection Class
403,500
32,800
1.30
26,200
17,820
13,836
3.868
0.264
3.340
2.989
11.751
8.762
2.523
5.046
S-135 )
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully
responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied
warranty is intended. Drill pipe assembly properties are calculated based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear
conditions (remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance
ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the application. For API connections that have different pin and box IDs, tool joint ID refers to
the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
www.NOV.com/GrantPrideco/CustomerFeedback
Connection
Pipe Body
TurboTorque 390
80 % Inspection Class
Tool Joint OD
(in)
4.875
Tool Joint ID
Pipe Body OD
(in)
(in)
2.688
S-135
(ft-lbs)
(ft-lbs)
Connection
Pipe Body
Max Tension Max Tension
Connection Max
Pipe Body
Max Tension Tension
(ft-lbs)
0
1,500
2,900
4,400
5,900
7,300
8,800
10,300
11,700
13,200
14,700
16,100
17,600
19,100
20,500
22,000
23,400
24,900
26,400
27,800
(lbs)
403,500
403,100
401,900
399,900
396,900
393,400
388,700
383,100
376,900
369,300
360,600
351,400
340,300
327,800
314,700
298,900
282,300
262,100
238,800
212,500
(lbs)
(ft-lbs)
(lbs)
(lbs)
(lbs)
(lbs)
403,500
412,600
403,500
403,500
685,700
403,100
412,600
1,000
403,300
403,300
685,700
412,600
1,900
402,800
402,800
685,700
412,600
2,900
401,900
401,900
685,700
685,700
401,900
399,900
396,900
412,600
3,800
400,800
400,800
393,400
412,600
4,800
399,200
399,200
685,700
388,700
412,600
5,800
397,100
397,100
685,700
383,100
412,600
6,700
395,000
395,000
685,700
376,900
412,600
7,700
392,200
392,200
685,700
412,600
8,700
389,000
389,000
685,700
412,600
9,600
385,800
385,800
685,700
381,800
381,800
685,700
685,700
369,300
360,600
351,400
10,600
412,600
340,300
412,600
11,500
377,800
377,800
327,800
412,600
12,500
373,000
373,000
685,700
314,700
412,600
13,500
367,700
367,700
685,700
412,600
14,400
362,400
362,400
685,700
412,600
15,400
356,100
356,100
685,700
349,300
349,300
685,700
685,700
685,700
298,900
282,300
262,100
16,400
412,600
238,800
412,600
17,300
342,600
342,600
212,500
412,600
18,300
334,900
334,900
Connection
Make-up Torque Range
(ft-lbs)
Min MUT
Rec MUT
21,200
22,100
23,100
24,000
25,000
25,900
26,900
27,800
28,800
29,700
Connection Max
Tension
(lbs)
685,700
658,600
626,200
597,100
564,700
535,600
503,200
474,100
441,700
412,600
Note: Recommended MUT should always be used when possible. If not possible, MUT should be as close to Recommended MUT as possible.
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
Connection
Tool Joint OD
TurboTorque 390
Connection
Wear
Tool
Joint OD
New OD
(in)
4.875
4.848
4.821
4.794
4.767
4.74
4.712
4.685
4.658
4.631
4.604
4.577
Worn OD
(in)
4.875
Tool Joint ID
(in)
2.688
Connection
Torsional
Strength (ft-lbs)
42,500
42,400
42,000
41,000
40,000
39,000
38,000
37,000
36,000
35,000
34,100
33,100
29,700
29,700
29,400
28,700
28,000
27,300
26,600
25,900
25,200
24,500
23,900
23,200
(ft-lbs)
Connection Max
Tension
Min MUT
Tension
(lbs)
(ft-lbs)
412,600
410,300
417,600
437,600
457,400
477,000
496,300
515,400
534,400
546,900
541,000
536,700
(lbs)
21,200
685,700
21,200
684,500
21,000
685,800
20,500
672,800
20,000
659,800
19,500
646,700
19,000
633,700
18,500
620,600
18,000
607,300
17,500
587,400
17,000
552,700
16,600
522,100
Pipe Body
Combined Loading Table (Torque-Tension)
Pipe Body
Pipe Body OD
80 % Inspection Class
(in)
S-135
3,000
6,000
8,900
11,900
14,900
17,900
20,800
23,800
26,800
29,800
32,700
401,800
396,700
388,300
375,900
359,400
337,900
311,700
277,200
232,000
167,400
22,900
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
TorqueTensionGraph
Connection: TurboTorque 390 (4.875 (in) OD X 2.688 (in) ID) SMYS = 130,000 (psi)
PipeBody:80%InspectionClass,4.000(in)OD,0.330(in)wallthickness,S135PipeGrade
(safetyfactor=1.0)
800,000
PipeBodyinCombinedLoading
PipeBodyYieldat80%
InspectionClass
700,000
ConnectionPerformance(basedonMUT)
ToolJointYield
600,000
ToolJointShoulderSeparation
TJOperationalLimit(RecMUT)
Tension(lbs)
500,000
TJOperationalLimit(MinMUT)
400,000
300,000
200,000
100,000
Torque(ftlbs)
OverloadZone
400,000
350,000
Tension(lbs)
300,000
250,000
Operationallimit(safetyfactor=1.0)
200,000
150,000
100,000
50,000
OperationalTorque(ftlbs)
OverloadZone
400,000
350,000
Tension(lbs)
300,000
250,000
Operationallimit(safetyfactor=1.0)
200,000
150,000
100,000
50,000
OperationalTorque(ftlbs)
ConnectionWearforTurboTorque390(4.875(in)ODX2.688(in)ID)
Material SMYS (specified minimum yield strength) = 130,000 (psi)
45,000
40,000
35,000
Connection
30,000
Torque(ftlbs)
TorsionalStrength
RecommendedMUT
25,000
MinimumMUT
20,000
PipeBody
80% ofPremiumPipe
BodyTorsionalStrength
15,000
PipeBody:4.000(in)OD,0.330(in)wall
thickness,S135PipeGrade
10,000
5,000
ToolJointOD(in)