COMPROTware Test Tool

RTU560 Training
COMPROTware_E.ppt

COMPROTware Test Tool

General Information
Pre-defined Telegrams
Communication Settings

IEC 60870-5-101

IEC 60870-5-104

Additional Test Equipment

RTU560 Training
COMPROTware_E.ppt

COMPROTware Test Tool, Capabitilies


Simulating NCC

Master

Master

Slave

Slave

Simulating SubRTU

RTU560 Training
COMPROTware_E.ppt

COMPROTware Test Tool, Capabitilies


Listening Mode

NCC

RTU560 Training
COMPROTware_E.ppt

COMPROTware Test Tool, Conventions


Naming conventions:
Master
Controlling Station
Slave
Controlled Station
File Types:
*.mlg = recorded log files
*.mls = message lists to be sent
*.cppt = configuration files
Colors:
green = Controlling Station
blue
= Controlled Station
RTU560 Training
COMPROTware_E.ppt

COMPROTware Test Tool, Conventions


Cause of Transmission
act
act
actcon
actcon
actterm
actterm

+
+
+
-

: Activation command, positive


: Activation command, negative
: Activation confirmation, positive
: Activation confirmation, negative
: Activation termination, positive
: Activation termination, negative

Qualifier:
CAPITAL LETTER
small letter

: Qualifier is TRUE
: Qualifier is FALSE

iv
IV

: Qualifier Value is valid


: Qualified Value is invalid

means
means

RTU560 Training
COMPROTware_E.ppt

NCC
NCC
RTU
RTU
RTU
RTU

COMPROTware Test Tool, Screenshot Example

RTU560 Training
COMPROTware_E.ppt

COMPROTware Test Tool, Screenshot Control

RTU560 Training
COMPROTware_E.ppt

COMPROTware Test Tool

General Information
Pre-defined Telegrams
Communication Settings

IEC 60870-5-101

IEC 60870-5-104

Additional Test Equipment

RTU560 Training
COMPROTware_E.ppt

COMPROTware Test Tool, Pre-defined Telegrams


Pre-defined telegrams are stored in Message Lists, and can
be used every time, the communication is established. Because
these telegrams are protocol-dependant, the used protocol
has to be declared, before new telegrams can be generated.

Dialogue: Edit -> Protocol Profile -> IEC 60870-5 -> IEC 60870-5-101
RTU560 Training
COMPROTware_E.ppt

10

COMPROTware Test Tool, Pre-defined Telegrams


Creating a new telegram

Dialogue: Edit -> Message List Storage -> File -> New
RTU560 Training
COMPROTware_E.ppt

11

COMPROTware Test Tool, Pre-defined Telegrams

Create a Message List

Dialogue: <Message List name>


-> OK -> <Empty List>

RTU560 Training
COMPROTware_E.ppt

12

COMPROTware Test Tool, Pre-defined Telegrams

Dialogue: Edit -> Add ->


<Enter Telegram>

RTU560 Training
COMPROTware_E.ppt

13

COMPROTware Test Tool, Pre-defined Telegrams

Select Type Ident from the List.


Select COT from the List.

You can also use the number


for Type Ident and COT.

RTU560 Training
COMPROTware_E.ppt

14

COMPROTware Test Tool, Pre-defined Telegrams

The new telegram


appears on the list

Select Common Address


Select Information Object
Press Set

RTU560 Training
COMPROTware_E.ppt

15

COMPROTware Test Tool, Pre-defined Telegrams

You can set the


Message send mode

You can add another


telegram to the list

RTU560 Training
COMPROTware_E.ppt

16

COMPROTware Test Tool, Pre-defined Telegrams

If you are online


you can send the telegram

Overview of all Message Lists

RTU560 Training
COMPROTware_E.ppt

17

COMPROTware Test Tool

General Information
Pre-defined Telegrams
Communication Settings

IEC 60870-5-101

IEC 60870-5-104

Additional Test Equipment

RTU560 Training
COMPROTware_E.ppt

18

COMPROTware Test Tool, Settings IEC 60870-5-101


Dialogue:
-> Edit
-> Protocol Profile
-> IEC 60870-5
-> IEC 60870-5-101
-> Continue

All settings of CPTT


have to be done
according to the
settings in RTUtil560

RTU560 Training
COMPROTware_E.ppt

19

COMPROTware Test Tool, Settings IEC 60870-5-101


Line Settings IEC 60870-5-101 in RTUtil560

RTU560 Training
COMPROTware_E.ppt

20

COMPROTware Test Tool, Settings IEC 60870-5-101


Communication Settings IEC 60870-5-101 in RTUtil560

RTU560 Training
COMPROTware_E.ppt

21

COMPROTware Test Tool, Settings IEC 60870-5-101


Line Settings IEC 60870-5-101 in RTUtil560

RTU560 Training
COMPROTware_E.ppt

22

COMPROTware Test Tool

General Information
Pre-defined Telegrams
Communication Settings

IEC 60870-5-101

IEC 60870-5-104

Additional Test Equipment

RTU560 Training
COMPROTware_E.ppt

23

COMPROTware Test Tool, Settings IEC 60870-5-104

A TCP/IP - connection is characterized by


IP-Address and port number of sender and
IP-Address and port number of receiver
The port number of RTUs is fixed to 2404.
The port number of PCs is dynamically distributed at
startup. Router should not block port 2404.

RTU560 Training
COMPROTware_E.ppt

24

COMPROTware Test Tool, Settings IEC 60870-5-104

RTU560 Training
COMPROTware_E.ppt

25

COMPROTware Test Tool, Settings IEC 60870-5-104

Use Master IP Address,


if there is one or more
network control center
with exclusive access
right to the RTU.

RTU560 Training
COMPROTware_E.ppt

26

COMPROTware Test Tool, Settings IEC 60870-5-104


Settings COMPROTware
IP address
of RTU

IP address
of NCC

RTU560 Training
COMPROTware_E.ppt

27

COMPROTware Test Tool, Starting the Communication

Dialogue:
Action -> Simulate Controlling Station
( Master / NCC )

RTU560 Training
COMPROTware_E.ppt

28

Look into the Statistics

COMPROTware Test Tool

General Information
Pre-defined Telegrams
Communication Settings

IEC 60870-5-101

IEC 60870-5-104

Additional Test Equipment

RTU560 Training
COMPROTware_E.ppt

29

COMPROTware Test Tool, Listening Cable 23PK22


PC
COM 1

PC
COM 2

2
3
7
Ground

2
5
Ground

2
5
Ground
a

23PK22

PC
COM 1

typ. 3 m

typ. 0,5 m

PC
COM 2

RTU560 Training
COMPROTware_E.ppt

30

COMPROTware Test Tool, Master Cable 23PK27

RTU560 Training
COMPROTware_E.ppt

31

COMPROTware Test Tool, Adaptor 23PK30


Application 1 - Listen mode on line to modem:
RJ45 - 1:1 - cable from CMU to INPUT
23PK22 from Listen-PC to Listen others
Output DB25, DB9 or RJ45 to Modem, Master, ...
Output
Application 2 - Listen mode at fibre optic or RS485:

Input

RJ45 - 1:1 - Cable from 23OK24 SFC to INPUT


23PK22 from Listen-PC to Listen 23OK24
Output not used
Application 3 - Slave-mode:
INPUT not used
23PK27 from Slave-PC to RJ45 Slave
Output DB25, DB9 or RJ45 to Modem, Master, ...

RTU560 Training
COMPROTware_E.ppt

32

COMPROTware Test Tool, Adaptor 23PK30

Adaptor 23PK30

23PK27
from/to
RTU560
23PK27 from/to
Master-PC
(Simulation NCC)
23PK22 listen cable from/to
COM1 and COM 2 of listening PC

RTU560 Training
COMPROTware_E.ppt

33

COMPROTware Test Tool, Further Information

For further information see :


COMPROTware: Testtool
Users Guide

RTU560 Training
COMPROTware_E.ppt

34