You are on page 1of 5

CMM 4-15-42 WS3012

COMBINED CONCRETE AGGREGATE GRADATION


PROJECT DESCRIPTION

SAMPLE INFORMATION

Project ID.

Contract

Sampled By:

Highway

County

Date:

Description

Time:

Contractor

Sample No.

Determination of Combined Aggregate Gradation (% Passing)


Aggregate Batched Proportions:

Course Aggregate #2 (C.A. #2) =


Course Aggregate #1 (C.A. #1) =
Fine Aggregate (F.A.) =

0.0%

Plant Site Aggregate Samples (% Passing)


C.A. #2

Size

C.A. #1

Calculate Combined Gradation (% Passing)


F.A.

C.A. #2

C.A. #1

F.A.

Combined

2" (50 mm)

0.0%

0.0%

0.0%

0.0%

1 1/2" (37.5 mm)

0.0%

0.0%

0.0%

0.0%

1" (25 mm)

0.0%

0.0%

0.0%

0.0%

3/4" (19 mm)

0.0%

0.0%

0.0%

0.0%

3/8" (9.5 mm)

0.0%

0.0%

0.0%

0.0%

#4 (4.75 mm)

0.0%

0.0%

0.0%

0.0%

#8 (2.36 mm)

0.0%

0.0%

0.0%

0.0%

#16 (1.16 mm)

0.0%

0.0%

0.0%

0.0%

#30 (0.6 mm)

0.0%

0.0%

0.0%

0.0%

#50 (0.3 mm)

0.0%

0.0%

0.0%

0.0%

#100 (0.15 mm)

0.0%

0.0%

0.0%

0.0%

#200 (0.075 mm)

0.00%

0.00%

0.00%

0.00%

Determination of Specification Limits for Combined Aggregate Gradation (% Passing)


C.A. #2

C.A. #1

F.A.

Combined

Sieve
Size

Spec.

2"

100.0

1 1/2" 90.0

LCL

UCL

Spec.

- 100.0

0.0

0.0

LCL

UCL

Spec.

LCL

UCL

LCL

UCL

100.0

0.0

100.0

0.0

100.0

0.0

100.0

0.0

0.0

0.0

100.0

0.0

0.0

0.0

100.0

0.0

0.0

0.0

1"

20.0

55.0

0.0

0.0

3/4"

0.0

15.0

0.0

0.0

90.0

- 100.0

0.0

0.0

3/8"

0.0

5.0

0.0

0.0

20.0

55.0

0.0

0.0

0.0

0.0

#4

0.0

5.0

0.0

0.0

0.0

10.0

0.0

0.0

90.0

- 100.0

0.0

0.0

0.0

0.0

#16

0.0

5.0

0.0

0.0

0.0

5.0

0.0

0.0

45.0

80.0

0.0

0.0

0.0

0.0

#50

0.0

5.0

0.0

0.0

0.0

5.0

0.0

0.0

10.0

30.0

0.0

0.0

0.0

0.0

#100

0.0

5.0

0.0

0.0

0.0

5.0

0.0

0.0

2.0

10.0

0.0

0.0

0.0

0.0

#200 0.00

1.50

0.00

0.00

0.00

1.50

0.00

0.00

0.00

3.50

0.00

0.00

0.00

0.00

LCL = Lower Control Limit


UCL = Upper Control Limit

100.0

0.0

0.0

100.0

0.0

CMM 4-15-42 WS3012

SUMMARY OF COMBINED AGGREGATE GRADATION SPECIFICATION LIMITS


PERCENT PASSING

Combined

Combined

Concrete

Concrete

Gradation

Gradation

Pavement

Structure

Sieve

Combined

Combined

Combined

% Retained

% Between

QMP Spec

QMP Spec

Size

LCL

Gradation

UCL

On Sieve

Sieves

% Passing

% Passing

2" (50 mm)

0.0

0.0%

0.0

100.0%

100%

100%

1 1/2" (37.5 mm)

0.0

0.0%

0.0

100.0%

0.0%

1" (25 mm)

0.0

0.0%

0.0

100.0%

0.0%

3/4" (19 mm)

0.0

0.0%

0.0

100.0%

0.0%

3/8" (9.5 mm)

0.0

0.0%

0.0

100.0%

0.0%

#4 (4.75 mm)

0.0

0.0%

0.0

100.0%

0.0%

100.0%

0.0%

100.0%

0.0%

100.0%

0.0%

100.0%

0.0%

0.0%

#8 (2.36 mm)
#16 (1.16 mm)

0.0

0.0%

0.0

0.0%

#30 (0.6 mm)


#50 (0.3 mm)

0.0

0.0%

0.0

#100 (0.15 mm)

0.0

0.0%

0.0

100.0%

0.0%

#200 (0.075 mm)

0.0

0.00%

0.0

100.00%

0.00%

< or = 89%

< or = 42%*

< or = 42%**

< or = 2.3%

< or = 2.3%

* 47 % if coarse material is composed completely of crushed stone or recycled concrete.

LCL = Lower Control Limit

** 47 % if coarse material is composed completely of crushed stone.

UCL = Upper Control Limit

CMM 4-15-42 WS3012

COMBINED CONCRETE AGGREGATE GRADATION


PROJECT DESCRIPTION

SAMPLE INFORMATION

Project ID.

Contract

Sampled By:

Highway

County

Date:

Description

Time:

Contractor

Sample No.

Determination of Combined Aggregate Gradation (% Passing)


Aggregate Batched Proportions:

Course Aggregate #2 (C.A. #2) =

30.0%

Course Aggregate #1 (C.A. #1) =

30.0%

Fine Aggregate (F.A.) =

40.0%

100.0%

Plant Site Aggregate Samples (% Passing)


C.A. #2

Size

C.A. #1

Calculate Combined Gradation (% Passing)


F.A.

C.A. #2

C.A. #1

F.A.

Combined

2" (50 mm)

100.0%

100.0%

100.0%

30.0%

30.0%

40.0%

100.0%

1 1/2" (37.5 mm)

95.0%

100.0%

100.0%

28.5%

30.0%

40.0%

98.5%

1" (25 mm)

32.0%

100.0%

100.0%

9.6%

30.0%

40.0%

79.6%

3/4" (19 mm)

12.0%

97.0%

100.0%

3.6%

29.1%

40.0%

72.7%

3/8" (9.5 mm)

3.0%

27.0%

100.0%

0.9%

8.1%

40.0%

49.0%

#4 (4.75 mm)

3.0%

6.0%

96.0%

0.9%

1.8%

38.4%

41.1%

#8 (2.36 mm)

2.0%

2.0%

87.0%

0.6%

0.6%

34.8%

36.0%

#16 (1.16 mm)

2.0%

1.0%

73.0%

0.6%

0.3%

29.2%

30.1%

#30 (0.6 mm)

2.0%

1.0%

42.0%

0.6%

0.3%

16.8%

17.7%

#50 (0.3 mm)

2.0%

1.0%

16.0%

0.6%

0.3%

6.4%

7.3%

#100 (0.15 mm)

2.0%

1.0%

4.0%

0.6%

0.3%

1.6%

2.5%

#200 (0.075 mm)

1.50%

1.00%

3.00%

0.45%

0.30%

1.20%

1.95%

Determination of Specification Limits for Combined Aggregate Gradation (% Passing)


C.A. #2

C.A. #1

F.A.

Combined

Sieve
Size

Spec.

2"

100.0

1 1/2" 90.0

LCL

UCL

Spec.

30

- 100.0

27.0

30.0

LCL

UCL

Spec.

LCL

UCL

LCL

UCL

100.0

30.0

100.0

40.0

100.0

30.0

100.0

40.0

97.0

100.0

100.0

40.0

76.0

86.5

100.0

40.0

67.0

74.5

1"

20.0

55.0

6.0

16.5

3/4"

0.0

15.0

0.0

4.5

90.0

- 100.0

27.0

30.0

3/8"

0.0

5.0

0.0

1.5

20.0

55.0

6.0

16.5

46.0

58.0

#4

0.0

5.0

0.0

1.5

0.0

10.0

0.0

3.0

90.0

- 100.0

36.0

40.0

36.0

44.5

#16

0.0

5.0

0.0

1.5

0.0

5.0

0.0

1.5

45.0

80.0

18.0

32.0

18.0

35.0

#50

0.0

5.0

0.0

1.5

0.0

5.0

0.0

1.5

10.0

30.0

4.0

12.0

4.0

15.0

#100

0.0

5.0

0.0

1.5

0.0

5.0

0.0

1.5

2.0

10.0

0.8

4.0

0.8

7.0

#200 0.00

1.50

0.00

0.45

0.00

1.50

0.00

0.45

0.00

3.50

0.00

1.40

0.00

2.30

LCL = Lower Control Limit


UCL = Upper Control Limit

100.0

30.0

100.0

100.0

40.0

CMM 4-15-42 WS3012

SUMMARY OF COMBINED AGGREGATE GRADATION SPECIFICATION LIMITS


PERCENT PASSING

Combined

Combined

Concrete

Concrete

Gradation

Gradation

Pavement

Structure

Sieve

Combined

Combined

Combined

% Retained

% Between

QMP Spec

QMP Spec

Size

LCL

Gradation

UCL

On Sieve

Sieves

% Passing

% Passing

2" (50 mm)

100.0

100.0%

100.0

0.0%

100%

100%

1 1/2" (37.5 mm)

97.0

98.5%

100.0

1.5%

1.5%

1" (25 mm)

76.0

79.6%

86.5

20.4%

18.9%

3/4" (19 mm)

67.0

72.7%

74.5

27.3%

6.9%

3/8" (9.5 mm)

46.0

49.0%

74.5

51.0%

23.7%

#4 (4.75 mm)

36.0

41.1%

44.5

58.9%

7.9%

64.0%

5.1%

69.9%

5.9%

36.0%

#8 (2.36 mm)
#16 (1.16 mm)

18.0

30.1%

35.0

82.3%

12.4%

#50 (0.3 mm)

4.0

17.7%
7.3%

15.0

92.7%

10.4%

#100 (0.15 mm)

0.8

2.5%

7.0

97.5%

4.8%

#200 (0.075 mm)

0.0

1.95%

2.3

98.05%

0.55%

#30 (0.6 mm)

< or = 89%

< or = 42%*

< or = 42%**

< or = 2.3%

< or = 2.3%

* 47 % if coarse material is composed completely of crushed stone or recycled concrete.

LCL = Lower Control Limit

** 47 % if coarse material is composed completely of crushed stone.

UCL = Upper Control Limit

Header