You are on page 1of 2

Quantis

ATEX Certification

Introducing Dodge Quantis ATEX Certification


Gearing

ATEX certification is now available for Dodge Quantis Reducers,


manufactured under guidelines of the ATEX directive 94/9/EC.
These guidelines provide legal requirements for the manufacturing
of products that may be used in potentially explosive environments.
ATEX directive 94/9/EC is a required certification for explosion proof
applications through the European Union, as well as, many other
countries. ATEX certification is not required for North American
applications, as they would fall under the Class/Division Standard set
by NEC/CEC.

The Quantis ILH, RHB, & MSM size 38 and 48 reducers are suitable
for ATEX Category 2, Group II and I, for gas and dust environments.
The Quantis ILH, RHB, & MSM sizes 68-168 reducers are suitable for
ATEX Category 2 and M2 (mining), Group II and I, for gas and dust
environments. Dodge Quantis ILH, RHB and MSM reducers size 38-
168 are suitable for ATEX Category 3 for all gas and dust environments
within ignition temperatures higher than T4 (135 deg. C).
Quantis reducers with c-face clamp collar and three piece coupled
input configurations have a -30 to +50 deg. C ambient temperature
certification. Quantis reducers with separate input configurations have a
-30 to +45 deg C ambient temperature certification.
ATEX Certification Specifications:
ILH, RHB, MSM
Sizes 38-168
Single, Double, Triple Reduction
Clamp Collar, 3 PC Coupled, Separate Input (NEMA and IEC)
Steel KTR coupling used with 3 PC Coupled Input
All standard output shaft configurations (Inch and Metric)
B14 and B5 Output Flange options
Viton Input and Viton Output Seals
Washdown Breather*
Oil Sight Gage*
ATEX Certified Nameplate
ATEX Supplemental Instructions and Certification (MN16008)
*Excluded on size 38 reducers.

ILH RHB MSM


Reducer ATEX Certification Categories for Max Ratings Max Ratings Max Ratings
Size Dodge Quantis Reducers Input Power Torque Input Power Torque Input Power Torque
Hp (kW) In-Lbs (NM) Hp (kW) In-Lbs (NM) Hp (kW) In-Lbs (NM)

38 ATEX Category 8.87 (6.61) 1947 (220) 5.6 (4.18) 2213 (250) 7.45 (5.55) 2921 (330)
2 Group II and I,
for gas and dust
48 environments 13.88 (10.35) 3983 (450) 9.9 (7.38) 3985 (450) 7.7 (5.74) 4780 (540)

68 26.64 (19.86) 7081(800) 13.88 (10.35) 7262 (821) 26.92 (20.07) 8851 (1000)
ATEX Category
88 3 for all gas and 45.45 (33.89) 14870 (1680) 26.94 (20.09) 11638 (1315) 45.47 (33.90) 16817 (16817)
dust environments
ATEX Category 2 with ignition
108 and M2 (mining), temperatures 92.12 (68.68) 27438 (3100) 45.36 (33.82) 22430 (2534) 74.16 (55.29) 30093 (3400)
Group II and I, higher than T4
128 for gas and dust 135.98 (101.39) 45140 (5101) 92.65 (69.08) 41623 (4703) 133.21 (99.32) 53991 (6101)
environments
148 144.74 (107.92) 70808 (8001) 136.15 (101.51) 70848 (8005) 144.74 (144.74) 77004 (8701)

168 158.68 (118.31) 123914 (14002) 120.91 (90.15) 104886 (11852) 158.78 (118.39) 118603 (13401)

P.O. Box 2400, Fort Smith, AR 72902-2400 U.S.A., Ph: (1) 479.646.4711, Fax (1) 479.648.5792, International Fax (1) 479.648.5895
Baldor - Dodge
6040 Ponders Court, Greenville, SC 29615-4617 U.S.A., Ph: (1) 864.297.4800, Fax: (1) 864.281.2433
www.baldor.com
Baldor Electric Company All Rights Reserved. Printed in USA.