You are on page 1of 134

Mechanical FATJACK User's Manual

ANSYS, Inc. Release 15.0


Southpointe November 2013
275 Technology Drive
Canonsburg, PA 15317 ANSYS, Inc. is
ansysinfo@ansys.com certified to ISO
9001:2008.
http://www.ansys.com
(T) 724-746-3304
(F) 724-514-9494
Copyright and Trademark Information

2013 SAS IP, Inc. All rights reserved. Unauthorized use, distribution or duplication is prohibited.

ANSYS, ANSYS Workbench, Ansoft, AUTODYN, EKM, Engineering Knowledge Manager, CFX, FLUENT, HFSS and any
and all ANSYS, Inc. brand, product, service and feature names, logos and slogans are registered trademarks or
trademarks of ANSYS, Inc. or its subsidiaries in the United States or other countries. ICEM CFD is a trademark used
by ANSYS, Inc. under license. CFX is a trademark of Sony Corporation in Japan. All other brand, product, service
and feature names or trademarks are the property of their respective owners.

Disclaimer Notice

THIS ANSYS SOFTWARE PRODUCT AND PROGRAM DOCUMENTATION INCLUDE TRADE SECRETS AND ARE CONFID-
ENTIAL AND PROPRIETARY PRODUCTS OF ANSYS, INC., ITS SUBSIDIARIES, OR LICENSORS. The software products
and documentation are furnished by ANSYS, Inc., its subsidiaries, or affiliates under a software license agreement
that contains provisions concerning non-disclosure, copying, length and nature of use, compliance with exporting
laws, warranties, disclaimers, limitations of liability, and remedies, and other provisions. The software products
and documentation may be used, disclosed, transferred, or copied only in accordance with the terms and conditions
of that software license agreement.

ANSYS, Inc. is certified to ISO 9001:2008.

U.S. Government Rights

For U.S. Government users, except as specifically granted by the ANSYS, Inc. software license agreement, the use,
duplication, or disclosure by the United States Government is subject to restrictions stated in the ANSYS, Inc.
software license agreement and FAR 12.212 (for non-DOD licenses).

Third-Party Software

See the legal information in the product help files for the complete Legal Notice for ANSYS proprietary software
and third-party software. If you are unable to access the Legal Notice, please contact ANSYS, Inc.

Published in the U.S.A.


Table of Contents
1. FATJACK Introduction ............................................................................................................................. 1
2. FATJACK Theory ...................................................................................................................................... 3
2.1. Fatigue Assessment .......................................................................................................................... 3
2.2. S-N Curves ........................................................................................................................................ 3
2.3. Miner's Rule ...................................................................................................................................... 3
2.4. Deterministic Methods ..................................................................................................................... 4
2.5. Spectral Analysis ............................................................................................................................... 5
2.6. Time History Methods ....................................................................................................................... 7
2.7. Strategies for Wave Fatigue Analysis .................................................................................................. 7
2.8. Parametric SCF Equations ................................................................................................................ 13
3. FATJACK Analysis Methods ................................................................................................................... 35
3.1. Overview ........................................................................................................................................ 35
3.2. Environmental Information ............................................................................................................. 35
3.3. Joint Selection ................................................................................................................................ 35
3.4. Joint Classification .......................................................................................................................... 36
3.5. Inspection Points ............................................................................................................................ 37
3.5.1. Tubular Joint Inspection Points ............................................................................................... 37
3.5.2. Tubular Butt Joints ................................................................................................................. 37
3.5.3. Non-Tubular Braces ................................................................................................................ 38
3.6. Design Information ......................................................................................................................... 39
3.6.1. Design Geometry ................................................................................................................... 39
3.6.2. Secondary Elements ............................................................................................................... 39
3.7. Stress Concentration Factors ........................................................................................................... 39
3.7.1. Explicit SCF Definitions ........................................................................................................... 39
3.7.2. Empirical SCF Formulations .................................................................................................... 40
3.7.3. Influence Functions ................................................................................................................ 40
3.7.4. SCF Interpolation ................................................................................................................... 41
3.7.5. Annotated SCF File Generation ............................................................................................... 42
3.8. S-N Curves ...................................................................................................................................... 43
3.9. Units .............................................................................................................................................. 43
3.10. Element Cross Sections ................................................................................................................. 43
3.11. Results presentation ..................................................................................................................... 44
3.11.1. Obtaining Results ................................................................................................................. 44
3.11.2. FATJACK Results ................................................................................................................... 44
3.11.2.1. Fatigue Usage Factor Results ........................................................................................ 44
3.11.2.2. Damage per Wave Results ............................................................................................ 45
3.11.2.3. Stress Range Results .................................................................................................... 45
3.11.2.4. Stress Histogram Results .............................................................................................. 46
4. FATJACK Command Reference .............................................................................................................. 49
4.1. FATJACK Free Format Syntax ........................................................................................................... 49
4.1.1. General Description ............................................................................................................... 49
4.1.2. Special Symbols ..................................................................................................................... 51
4.2. FATJACK Priority of Data Assignments ............................................................................................. 53
4.3. Preliminary Data ............................................................................................................................. 54
4.4. Fatigue Analysis method ................................................................................................................. 55
4.4.1. ANALYSIS command ............................................................................................................... 55
4.4.2. Deterministic Analysis ............................................................................................................ 56
4.4.2.1. Deterministic Analysis Example ...................................................................................... 58
4.4.3. Spectral Analysis .................................................................................................................... 59
4.4.3.1. Spectral Analysis Example .............................................................................................. 62

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. iii
FATJACK User's Manual

4.4.4. Stress History Analysis ............................................................................................................ 65


4.4.4.1. Stress History Analysis Example ..................................................................................... 67
4.4.5. Time History Analysis ............................................................................................................. 69
4.4.5.1. Time History Analysis Example ....................................................................................... 70
4.5. ACCE .............................................................................................................................................. 71
4.6. ALLOWABLE .................................................................................................................................... 72
4.7. ANSYS ............................................................................................................................................ 72
4.8. CHORD ........................................................................................................................................... 73
4.9. COMPONENT .................................................................................................................................. 75
4.10. CURVE .......................................................................................................................................... 75
4.10.1. CURVE Command (User defined S-N curves) .......................................................................... 76
4.10.2. CURVE Command (Base thickness definition for standard curves) .......................................... 77
4.11. CYCLE ........................................................................................................................................... 78
4.12. DESIGN ......................................................................................................................................... 79
4.13. DETE ............................................................................................................................................. 80
4.14. END .............................................................................................................................................. 82
4.15. FILES ............................................................................................................................................. 82
4.16. FREQUENCY .................................................................................................................................. 83
4.17. GAP .............................................................................................................................................. 84
4.18. GAPDEFAULT ................................................................................................................................ 85
4.19. HIST .............................................................................................................................................. 85
4.20. INSET ............................................................................................................................................ 86
4.21. INSPECTION .................................................................................................................................. 87
4.21.1. INSPECTION Command (Tubular sections) ............................................................................ 87
4.21.2. INSPECTION Command (Non-tubular sections) ..................................................................... 89
4.22. JOB ............................................................................................................................................... 90
4.23. JOINT ............................................................................................................................................ 90
4.24. LIMIT ............................................................................................................................................ 91
4.25. NEWSTRUCTURE ........................................................................................................................... 93
4.26. OPTIONS ....................................................................................................................................... 93
4.27. PARAMETER .................................................................................................................................. 94
4.28. PRINT ........................................................................................................................................... 95
4.29. PROJECT ....................................................................................................................................... 96
4.30. REDUCTION .................................................................................................................................. 97
4.31. RESU ............................................................................................................................................. 97
4.32. SCF Definition ............................................................................................................................... 98
4.32.1. SCFANGLE Command ........................................................................................................... 99
4.32.2. SCF AUTO DEFAULT Command ............................................................................................ 100
4.32.3. SCF AUTO JOINT Command ................................................................................................ 102
4.32.4. SCFBRACE Command ......................................................................................................... 103
4.32.5. SCF DEFAULT Command ..................................................................................................... 104
4.32.6. SCFJOINT Command .......................................................................................................... 105
4.32.7. SCFMINIMUM Command .................................................................................................... 106
4.32.8. SCFPOINT Command .......................................................................................................... 107
4.33. SECONDARY ............................................................................................................................... 108
4.34. SIGM ........................................................................................................................................... 109
4.35. S-N ............................................................................................................................................. 110
4.36. SPECTRUM .................................................................................................................................. 111
4.37. SPREADING ................................................................................................................................. 113
4.38. STOP ........................................................................................................................................... 116
4.39. STRUCTURE ................................................................................................................................. 116
4.40. SYSTEM ....................................................................................................................................... 116

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
iv of ANSYS, Inc. and its subsidiaries and affiliates.
FATJACK User's Manual

4.41. TEXT ........................................................................................................................................... 117


4.42. THICKNESS .................................................................................................................................. 118
4.43. TITLE ........................................................................................................................................... 118
4.44. TRANSFER ................................................................................................................................... 119
4.45. TYPE ........................................................................................................................................... 120
4.46. UNITS ......................................................................................................................................... 121
4.47. WAVE .......................................................................................................................................... 122
4.48. YEAR ........................................................................................................................................... 123
5. FATJACK Appendices ........................................................................................................................... 125
5.1. Running FATJACK .......................................................................................................................... 125
5.1.1. ASAS Files Required by FATJACK ........................................................................................... 125
5.1.2. Files saved by FATJACK ......................................................................................................... 125
5.2. Section Profile Information ............................................................................................................ 125
5.2.1. BOX - Symmetric Fabricated Box Section ............................................................................... 125
5.2.2. RHS - Rolled Hollow Section .................................................................................................. 126
5.2.3. TUB - Tubes of Circular Section .............................................................................................. 126
5.2.4. WF - Wide Flanged Rolled I-Section ....................................................................................... 127
5.3. FATJACK References ...................................................................................................................... 127

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. v
Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
vi of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 1: FATJACK Introduction
FATJACK (FATigue calculations for offshore JACKets) is the fatigue calculation module. FATJACK is used
for the estimation of fatigue life for tubular and beam joints, employing deterministic or spectral
methods.

FATJACK represents a complete revamp of the philosophy as to how joint fatigue calculations are un-
dertaken, and embodies many new features that assist the designer in attaining optimal results with
the minimum of supplied data. The following facilities are provided by FATJACK.

Automatic retrieval of wave information from analysis databases

Selective processing of individual joints using node data

Design override capabilities to allow user defined joint configuration, member properties and secondary
members

Ability to compute SCF values at joints consisting of 1, 2 or 3 analysis node points

SCF values for a brace may be computed automatically using Kuang, Wordsworth, DS449 or Efthymiou
formulations

SCF values for a given brace may be computed from more than one empirical equation set allowing the
most appropriate equations to be adopted for specific inspection points around the brace

Computed SCFs may be output to a formatted file for modification and utilization in subsequent FATJACK
runs

Selective application of Marshall reduction factor and S-N thickness correction

S-N data may be input using standard pre-defined curves. User defined curves may now define a cut-off
value

Completely revised input data syntax allowing greater flexibility in data preparation

A brief overview of the analysis methods available is provided. For more detailed information see Ref.
1.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 1
Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
2 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 2: FATJACK Theory
This section discusses the following topics:
2.1. Fatigue Assessment
2.2. S-N Curves
2.3. Miner's Rule
2.4. Deterministic Methods
2.5. Spectral Analysis
2.6.Time History Methods
2.7. Strategies for Wave Fatigue Analysis
2.8. Parametric SCF Equations

2.1. Fatigue Assessment


Steel members subjected to a sufficiently large fluctuating tensile stress will develop small crack-like
defects which may eventually lead to failure of the member, the crack becomes sufficiently large to
cause fracture at the defect location. For structures subject to constant amplitude stress fluctuations,
problems of this nature may be avoided by keeping the cyclic stress below an endurance limit, preventing
the inception of the initial defect. Offshore structures, however, are exposed to a mixture of large and
small stress ranges making this approach impractical. It thus becomes necessary to design the structure
for a desired service life. The method used within FATJACK to carry out the fatigue assessment is based
upon the use of S-N curves.

2.2. S-N Curves


Tests of steel specimens subject to fluctuating loading demonstrate a relationship between the number
of cycles to failure, N, and the applied stress range, S. The form of this relationship is given by:

N = AS-m

where A and m are constants obtained experimentally.

In air, or where corrosion prevention is undertaken, an endurance limit can be identified for constant
amplitude stress cycling below which no fatigue occurs. For variable amplitude stress cycling the cut-
off stress decreases as the fatigue crack grows and this is often allowed for by changing the slope of
the S-N curve below a certain stress level.

Values of A and m are available for a range of typical joints. Values of A and m are available for a range
of typical joints. Many codes of practice provide one or more standard S-N curves, some of which have
been embodied within the FATJACK software.

2.3. Miner's Rule


To account for variable amplitude loading, the S-N curve is supplemented by an additional rule which
permits the fatigue assessment to be undertaken. Miners Rule is based upon the concept of fatigue
damage. For a given wave of constant amplitude the damage is given by:

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 3
FATJACK Theory

Where many wave cases are being analyzed, the fatigue damage for one wave case with a stress range
Si and a number of cycles ni is:

Miners Rule then gives the total annual damage as:

Since the calculation is based upon the number of cycles in a year for the constituent waves, the resulting
damage is that associated with one year of operation. The fatigue life (in years) is, therefore, the recip-
rocal of the damage; that is:

life = 1/D

Fatjack also calculates a usage figure, for easy comparison of results. This factor is based upon:

Usage = (DT)(1/S)

where:

D is the total damage

T is the target fatigue life

S is the slope of the S-N curve

2.4. Deterministic Methods


Deterministic fatigue methods apply Miners Rule directly.

The environmental loading is idealized by representative wave cases, each with a defined number of
loading cycles (or occurrences) in a year. The wave loading is generated (normally using Mechanical
APDL) to produce a series of loadcases which represent the waves for the required number of wave
heights, periods and directions. The structure is then analyzed to determine the stress S for each of the
loadcases and, hence, the fatigue life using Miners Rule.

Two analysis approaches are available to undertake a deterministic fatigue assessment.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
4 of ANSYS, Inc. and its subsidiaries and affiliates.
Spectral Analysis

Under normal circumstances, where the structure responds sinusoidally to the load, the wave loading
generates a loadcase pair for each wave case analyzed. This pair of loadcases represents the real and
imaginary parts of a solution which retains both magnitude and phase information. This is achieved by
undertaking a harmonic wave analysis within Mechanical APDL. This approach is an efficient and effective
way of determining the stress response of the structure to steady state harmonic loading. FATJACK uses
this data to generate the stress ranges directly from the incoming member forces for the loadcase pairs.

This methodology is selected using the ANALYSIS DETERMINISTIC command.

In situations where the structure stress response becomes nonlinear (for example, in shallow water), a
sinusoidal representation may become invalid in which case a more detailed analysis needs to be adopted.
The stress history approach utilizes the stresses resulting from discrete positions for a given wave to
determine explicitly the stress range. In this case Mechanical APDL is used to generate one or more
loadcases for each wave case to adequately define the response of the structure to the applied loading.
If only one loadcase is provided it is assumed to represent the stress amplitude. In this case the stress
range is computed as twice the amplitude. For any other number of loadcases the stress range is
computed as the difference between the maximum and minimum stress occurring within each of the
constituent loadcases forming the wave.

This methodology is selected using the ANALYSIS STRESS HISTORY command.

2.5. Spectral Analysis


When the dynamic response of the structure is important, a more realistic estimate of fatigue life can
be obtained from the spectral method. The damage is accumulated at each inspection point throughout
the frequency range, using the stress response spectrum at that point together with the appropriate
material S-N characteristics.

For the purpose of sea state identification, wave direction is usually classified into eight sectors of 45
incidence angle bands (Figure 2.1: Sea states are applied by direction sector scatter diagrams (p. 6)).
In each sector, the occurrence rate of each random sea state, characterized by significant wave height,
Hs, and mean zero crossing period, Tz, is identified as a number on a scatter diagram (Figure 2.2: A
scatter diagram summarizing the relative occurrence rate of individual sea state conditions for one
direction (p. 6)). The ratio of this number of occurrences to the total for all eight sector scatter diagrams
gives the weighting to be applied later in determining the amount of fatigue damage due to each sea
state.

In a particular random sea state, the instantaneous water surface elevation is considered to be caused
by the combined effect of an infinite number of steady state components of wave frequency having
random phase relationships. The amplitude content versus frequency has been shown by practical in-
vestigation to be related to the significant wave height and mean zero crossing period. Using relationships
such as the JONSWAP (Ref. 6), Scott-Weigel, Pierson-Moskowitz (Ref. 5) or Ochi-Hubble (Ref. 7) spectra,
each scatter diagram sea state can be reconstituted in terms of water surface elevation components
throughout the frequency range producing sea state spectra, S (See diagram (a) in Figure 2.3: Random
Sea States (p. 6)).

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 5
FATJACK Theory

Figure 2.1: Sea states are applied by direction sector scatter diagrams

Figure 2.2: A scatter diagram summarizing the relative occurrence rate of individual sea state
conditions for one direction

Figure 2.3: Random Sea States

For a given inspection point on the structure, a stress transfer function, f, is developed by computing
the normalized stress range for each of the constituent waves within a wave incidence sector, the

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
6 of ANSYS, Inc. and its subsidiaries and affiliates.
Strategies for Wave Fatigue Analysis

stresses being normalized by the associated wave heights (See diagram (b) in Figure 2.3: Random Sea
States (p. 6)).

The stress response spectrum for a given sea state, S, can then be determined by multiplying the
wave spectrum by the square of the associated stress transfer function (See diagram (c) in Figure 2.3: Ran-
dom Sea States (p. 6)).

Thus

S = S*2f

The fatigue damage incurred from one sea state at one stress inspection point is evaluated using
parameters from its stress response spectrum, the material fatigue data, Miners Rule and the relative
rate of occurrence of that sea state, including the assumption that the peak stress levels are distributed
according to a Rayleigh probability distribution (See diagram (d) in Figure 2.3: Random Sea States (p. 6)).

The damage in one year from each sea state for each inspection point is given by:

The annual damage from each of the sea states is then summed in order to give the total annual
damage from all sea states. The fatigue life is the reciprocal of the total annual damage.

For single slope S-N curves, the damage calculation is undertaken using a gamma function solution
which provides an efficient method for carrying out the integration expression. For multi-linear S-N
curves no such closed form solution exists and the integration has to be undertaken by numerical in-
tegration techniques.

2.6. Time History Methods


The environmental loading is idealized by representative time history cases, each with a defined number
of occurrences in a year. The structural response in the time domain is computed for each required sea
state (normally by a transient analysis) to produce a series of stress time histories. FATJACK reads in the
analysis stress results to create a hot spot stress time history at each inspection location and utilizes
the rainflow counting method to produce a stress range histogram; that is, a table of number of cycles
vs. stress range. The fatigue life is then calculated using Miners rule as usual.

2.7. Strategies for Wave Fatigue Analysis


Depending upon the type of fatigue analysis to be undertaken, different ocean loading options are re-
quired before computing fatigue lives in FATJACK. For Mechanical APDL based analyses the following
defines the required data and approach for various types of fatigue analysis:

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 7
FATJACK Theory

Type Mechanical Loading require- FATJACK Notes


Analysis ments Analysis
Time History Dy- Transient Struc- Multiple Stress Time History Rainflow counting for a
namic tural Time Histories number of ocean environ-
ments
Time History De- Static Structural Individual Stress Stress His- Use multiple load sets to get
terministic Static Scenarios tory a stress range
Time History De- Transient Struc- Stress Time History Stress His- Use multiple load steps to
terministic Static tural tory get a stress range
Harmonic Determ- Harmonic Re- Real & Imaginary Determinist- Ocean loading can be gener-
inistic Static sponse Stresses ic ated using the HROCEAN,
STATIC option
Harmonic Spectral Harmonic Re- Real & Imaginary Spectral Ocean loading can be gener-
Static sponse Stresses ated using the HROCEAN,
STATIC option
Harmonic Spectral Harmonic Re- Real & Imaginary Spectral Ocean loading can be gener-
Dynamic sponse Stresses ated using the HROCEAN,
DYNAMIC option

The processes involved for various types of fatigue study when using the ANSYS Asas solver are sum-
marized in Figure 2.4: Strategies for wave fatigue analysis using ANSYS Asas (p. 9).

Figure 2.5: Example of a time stress history fatigue analysis using ANSYS Asas (p. 10), Figure 2.6: Example
of a harmonic deterministic fatigue analysis (static) using ANSYS Asas (p. 11), and Figure 2.7: Example
of steady state dynamic spectral fatigue analysis using ANSYS Asas (p. 12) provide an overview of the
control data required to undertake the different fatigue analyses that are available in FATJACK. Fig-
ure 2.8: Example of a time history fatigue analysis using ANSYS Asas (p. 13) shows the control data re-
quired to undertake a time history fatigue analysis following a series of transient dynamic analyses.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
8 of ANSYS, Inc. and its subsidiaries and affiliates.
Strategies for Wave Fatigue Analysis

Figure 2.4: Strategies for wave fatigue analysis using ANSYS Asas

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 9
FATJACK Theory

Figure 2.5: Example of a time stress history fatigue analysis using ANSYS Asas

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
10 of ANSYS, Inc. and its subsidiaries and affiliates.
Strategies for Wave Fatigue Analysis

Figure 2.6: Example of a harmonic deterministic fatigue analysis (static) using ANSYS Asas

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 11
FATJACK Theory

Figure 2.7: Example of steady state dynamic spectral fatigue analysis using ANSYS Asas

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
12 of ANSYS, Inc. and its subsidiaries and affiliates.
Parametric SCF Equations

Figure 2.8: Example of a time history fatigue analysis using ANSYS Asas

2.8. Parametric SCF Equations

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 13
FATJACK Theory

Key:

= d/D

= D/(2T)

= t/T

= L/R

= g/D

D = chord outside diameter = 2R

d = brace outside diameter = 2r

T = chord thickness

t = brace thickness

= acute brace to chord angle

L = chord length

g = separation between brace toes (gap)

Table 2.1: Wordsworth Equations For SCFs In T/Y-joints

Validity Range
The following Wordsworth equations are generally valid for joint
parameters within the following limits:

0.13 <= <= 1.0

12 <= <= 32

0.25 <= <= 1.0

30 <= <= 90

8 <= <= 40

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
14 of ANSYS, Inc. and its subsidiaries and affiliates.
Parametric SCF Equations

Load Type SCF Equation Eqn. No.


Axial load
WT1

WT2

In-plane
bending WT3

Out-of-plane
bending WT4

Brace side
SCFs

Table 2.2: Wordsworth Equations For SCFs In X-joints

Load Type SCF Equation Eqn. No.


Axial load
WX1

WX2

In-plane
bending WX3

Out-of-plane
bending (bal- WX4
anced)

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 15
FATJACK Theory

Load Type SCF Equation Eqn. No.


Brace side
SCFs

Table 2.3: Wordsworth Equations For SCFs In K-joints

Load Type SCF Equation Eqn. No.


Balanced axi-
al load

WK1

WK2

WK3

In-plane
bending
WK4

Out-of-plane
bending (un-
balanced)

WK5

Brace side
SCF's

Table 2.4: Wordsworth Equations For SCFs In KT-joints

Load Type SCF Equation Eqn. No.


Balanced axi- Outer two braces only loaded.
al load
Equations identical to those given for K joints may be used except that
g is the distance between the toes of the outer braces (gac).

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
16 of ANSYS, Inc. and its subsidiaries and affiliates.
Parametric SCF Equations

Load Type SCF Equation Eqn. No.


In-plane WKT1
bending

Unbalanced
out-of-plane
bending

WKT2

WKT3

For brace C replace gab with gbc, A with C, C with A, A with C, C


with A and A with C.

The above equations were derived with equal sized braces. Caution
should therefore be used when applying the equations to nodes where
there is a large variation in brace dimensions.
Brace load
SCFs

Table 2.5: Kuang Equations In T/Y-joints

Validity Range
The following Kuang equations for T/Y, K and KT joints are
generally valid for joint parameters within the following limits:

0.3 <= <= 0.8 unless stated otherwise

8.33 <= <= 33.3

0.20 <= <= 0.8

0 <= <= 90 unless stated otherwise

6.667 <= <= 40

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 17
FATJACK Theory

Load Type SCF Equation Eqn. No.


Axial load KT1

KT2

In-plane KT3
bending

KT4

Out-of-plane KT5
bending KT6

KT7
KT8

Table 2.6: Kuang Equations In K-joints

Load Type SCF Equation Eqn. No.


Axial
load KK1

KK2

In-plane
bending KK3

KK4

Out-of-plane
bending KK5
KK6

KK7
KK8

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
18 of ANSYS, Inc. and its subsidiaries and affiliates.
Parametric SCF Equations

Table 2.7: Kuang Equations In KT-joints

Load Type SCF Equation Eqn. No.


Axial
load
KKT1

KKT2
KKT3

KKT4

In-plane
bending
KKT5

KKT6

Out-of-plane
bending
KKT7
KKT8

KKT9
KKT10

Table 2.8: Kuang Equations In T-joints

Load Type SCF Equation Eqn. No.


Axial load

DT1

DT2

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 19
FATJACK Theory

Load Type SCF Equation Eqn. No.


In-plane
bending
DT3

DT4

Out-of-
plane bend-
ing DT5

DT6

Table 2.9: Danish Equations In Y-joints

Validity Range
The following Danish equations for Y, K and KT joints are
generally valid for joint parameters within the following limits:

0.3 <= <= 0.8

8 <= <= 33

0.2 <= <= 0.8

0 <= <= 90

7 <= <= 40

0.01 <= <= 1.0

Load Type SCF Equation Eqn. No.


The following equations provide the basic SCF formulas for Y
joints. The code permits a reduction to be applied which is
automatically carried out by the program. The actual SCF value
computed is given by:

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
20 of ANSYS, Inc. and its subsidiaries and affiliates.
Parametric SCF Equations

Load Type SCF Equation Eqn. No.

Axial load

DY1

DY2

In-plane
bending
DY3

DY4

Out-of-plane
bending DY5
DY6

DY7
DY8

Table 2.10: Danish Equations In K and KT-joints

Load Type SCF Equation Eqn. No.


The following equations provide the basic SCF formulas for K and KT
joints. The code permits a reduction to be applied which is automatic-
ally carried out by the program. The actual SCF value computed is
given by:

Axial load K-
joints
DK1

DK2

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 21
FATJACK Theory

Load Type SCF Equation Eqn. No.


Axial load
KT-joints
DKT1

DKT2

DKT3

In-plane
bending
DK3

DK4

Out-of-plane
bending

Table 2.11: Danish Equations In X-joints

Validity Range
The following Danish equations for X joints are generally valid
for joint parameters within the following limits:

0.13 <= <= 0.95

12 <= <= 32

0.25 <= <= 1.0

30 <= <= 90

8 <= <= 40

Load Type SCF Equation Eqn. No.


Axial load

DX1

DX2

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
22 of ANSYS, Inc. and its subsidiaries and affiliates.
Parametric SCF Equations

Load Type SCF Equation Eqn. No.


In-plane
bending
DX3

DX4

Out-of-plane
bending
DX5

DX6

Table 2.12: Efthymiou Equations For SCFs In T/Y-joints

Validity Range
The following Efthymiou equations for T/Y joints are generally
valid for joint parameters within the following limits:

0.25 <= <= 1.0

8 <= <= 32

0.25 <= <= 1.0

20 <= <= 90

4 <= <= 40

-0.6/sin <= <= 1.0

Load Type SCF Equation Eqn. Short


No. Chord Cor-
rection
Axial load -
general fix- ET5 If C < 0.8
ity condi- F1 else F2
tions
ET6 None

ET3 If C < 0.8


F1 else F2

ET7 None

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 23
FATJACK Theory

Load Type SCF Equation Eqn. Short


No. Chord Cor-
rection
In-plane
bending ET8 None

ET9 None

Out-of-plane
bending ET10 F3

ET11 F3

Short chord correction factors ( < 12) Chord-end fixity parameter

Table 2.13: Efthymiou Equations For SCFs In X-joints

Load Type SCF Equation Eqn. Short Chord


No. Correction
Axial load
EX1 If C < 0.8
F1 else F2

EX2 None

EX3 If C < 0.8


F1 else F2

EX4 None

In-plane
bending None

None

Out-of-plane
bending EX5 F3

EX6 F3

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
24 of ANSYS, Inc. and its subsidiaries and affiliates.
Parametric SCF Equations

Table 2.14: Efthymiou Equations For SCFs In Gap/Overlap K-joints

Load Type SCF Equation Eqn. Short Chord


No. Correction
Balanced axial
load
EK1 None

EK2 None

Unbalanced
in-plane
bending

EK3

Unbalanced
out-of-plane
bending EK4 F4

EK5 F4

[ET10]A is the chord SCF adjacent to brace A as estimated from eqn ET10.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 25
FATJACK Theory

Note that the designation of braces A and B is not geometry-dependent, it is nominated by the user.

Table 2.15: Efthymiou Equations For SCFs In KT-joints

Load Type SCF Equation Eqn. Short Chord


No. Correction
Balanced axial
load

In-plane
bending

Out-of-plane
bending
EKT1 F4

EKT2 F4

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
26 of ANSYS, Inc. and its subsidiaries and affiliates.
Parametric SCF Equations

Table 2.16: Efthymiou Equations For SCFs In X-joints For Use In Influence Function Calculations

Load Type SCF Equation Eqn. Short Chord


No. Correction
Axial load on
reference EX7 If C < 0.8
brace only F1 else F2

EX8 If C < 0.8


F1 else F2

Out-of-plane
bending on F3
reference
brace only F3

Table 2.17: Efthymiou Influence Functions For X-joints

Load Type Influence function for reference brace Eqn. No.


Axial load

EIX1

EIX2

EIX3

EIX4

Out-of-plane
bending
EIX5

EIX6

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 27
FATJACK Theory

Note that in the above expressions subscript A refers to the reference brace, subscript B to the interacting
brace under consideration.

Table 2.18: Efthymiou Equations For SCFs In Gap/Overlap K-joints For Use In Influence Function
Calculations

Load Type SCF Equation Eqn. Short Chord


No. Correction
Axial load on
one brace If C < 0.8 F1 else F2
only
None

If C < 0.8 F1 else F2

None

If no braces are present on the opposite side of the chord,


m = 0
In-plane
bending on None
one brace
only
None

Out-of-plane
bending on
one brace EK6 F3
only

EK7 F3

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
28 of ANSYS, Inc. and its subsidiaries and affiliates.
Parametric SCF Equations

Note that in the above expressions subscript A refers to the reference brace, subscript B to the interacting
brace under consideration.

Table 2.19: Efthymiou Influence Functions For K-joints

Load Type Influence function for brace A Eqn. No.


Axial load

EIK1

EIK2

EIK3

EIK4

Out-of-plane
bending
EIK5

EIK6

Load Type Influence function for brace A Eqn. No.


Axial load

EIK1

EIK2

EIK3

EIK4

Out-of-plane
bending
EIK5

EIK6

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 29
FATJACK Theory

Note that in the above expressions subscript A refers to the reference brace, subscript B to the interacting
brace under consideration.

Table 2.20: Efthymiou Equations For SCFs in KT-joints For Use In Influence Function Calculations

Load Type SCF Equation Eqn. No.


Axial load on
reference
brace only

Out-of-plane
bending on
reference EKT3
brace only

EKT4

Load Type SCF Equation Eqn. No.


Axial load
on reference
brace only

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
30 of ANSYS, Inc. and its subsidiaries and affiliates.
Parametric SCF Equations

Load Type SCF Equation Eqn. No.


Out-of-plane
bending on
reference EKT3
brace only

EKT4

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 31
FATJACK Theory

Table 2.21: Efthymiou Influence Functions For KT-joints

Load Influence function for brace A Eqn. No.


Type
Axial

EIKT1

EIKT2

EIKT3

EIKT4

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
32 of ANSYS, Inc. and its subsidiaries and affiliates.
Parametric SCF Equations

Table 2.22: Efthymiou Hot-Spot Stresses In KT-joints

Load Type Hot spot stress expression Eqn. No.


Out-of-
plane
bending EIKT5

EIKT6

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 33
Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
34 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 3: FATJACK Analysis Methods
This section discusses the following topics:
3.1. Overview
3.2. Environmental Information
3.3. Joint Selection
3.4. Joint Classification
3.5. Inspection Points
3.6. Design Information
3.7. Stress Concentration Factors
3.8. S-N Curves
3.9. Units
3.10. Element Cross Sections
3.11. Results presentation

3.1. Overview
Fatigue analyses can require large amounts of data due to the methods employed in determining the
hot spot stresses from the nominal brace loads. In addition, the mathematical model is often greatly
simplified especially at joints where brace center-lines are assumed to pass through a common point
and where stub and/or can details have been omitted.

FATJACK includes an extensive command set which enables the user to automatically generate much
of the required data and provides methods for developing a more precise definition of the problem
than can be obtained from the analysis model.

3.2. Environmental Information


Fatigue analyses require information about the wave loading used to develop the analytical results that
are to be processed. FATJACK requires that wave height, period and direction are supplied for each
wave case that has been analyzed. For stress history analyses, it is also necessary for the program to
know how many wave positions have been used for each wave case (see Deterministic Methods (p. 4)).

Provided that the environmental wave loading has been generated using the ocean definition in
Mechanical APDL, FATJACK can automatically extract the wave information from the analysis database
files. It should be noted, however, that this facility is not available if the loading has been modified in
any way. In these cases the wave information must be supplied as part of the FATJACK input data.

3.3. Joint Selection


FATJACK allows selective processing of one or more individual joints in the model. This permits specific
areas of a model to be examined with local changes in design information.

The joints may either be listed explicitly or using the keyword ALL to request that every joint which
has valid elements connected is to be processed. Only BEAM and TUBE elements will be used by FATJACK,
all other element types will be ignored.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 35
FATJACK Analysis Methods

Joints are usually represented by a single node, to which the brace and chord elements are attached.
It is sometimes necessary to model the physical separation of work points in a joint by the use of 2 or
3 nodes.

This is achieved using a combination of CHORD and TYPE commands. In these cases one of the nodes
is designated as the joint node and this is used when referring to any properties regarding that joint.

3.4. Joint Classification


By default FATJACK utilizes the configuration of the brace members incident at a joint to determine
the joint classification used for computing stress concentration factors for the brace connections to the
joint.

Unless otherwise defined (by using the CHORD command) the chord at a given joint is selected based
upon the connecting members with the largest diameter. Where several members have the same dia-
meter, the elements with the largest thickness are adopted. In certain circumstances this process will
not produce a unique chord definition; for example, at X joints with similar members, in which case the
chord specification is compulsory. It should also be noted that where the chord elements are determined
by the program the chord length required for the stress concentration factor (SCF) calculations will be
computed as 2/3 times the combined lengths of the selected elements. This will produce erroneous
SCFs if the chord elements selected do not completely define the chord member; for example, where
intermediate nodes have been included. Either all the elements which constitute the chord should be
defined, or an explicit chord length should be given, using the CHORD command.

The remaining members at a joint, considered to be brace members, are then separated into groups
of elements that are in the same chord-brace plane. Within each plane a joint configuration is identified
for each brace end using the following classification table:

Nnear Nfar Classification


1 0 T/Y
1 1 X
1 2 T/Y
1 3 T/Y
2 any K
3 any KT

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
36 of ANSYS, Inc. and its subsidiaries and affiliates.
Inspection Points

Notes

1. Nnear is the number of braces on the same side of the chord as the brace under consideration (including
the brace under consideration).

2. Nfar is the number of braces on the far side of the chord with respect to the brace under consideration.

3. If the angle subtended with the chord is 90o5o then the reference brace is designated as a T, otherwise
the joint is classified as a Y.

If the user wishes to assign joint classifications other than that provided by the program this can be
achieved by using TYPE commands for the joint/brace combinations concerned. Note that TYPE com-
mands are ignored if using influence functions since this relies on a knowledge of all braces at a joint.

3.5. Inspection Points


Results from FATJACK are reported at one or more inspection points for braces connected to selected
joints. The location of the inspection points for braces are identified by an angle for tubular sections,
or a pair of ordinates for non-tubular braces. The reference point from which the angles or ordinates
are measured depends upon the type of joint being examined.

3.5.1. Tubular Joint Inspection Points


Where a joint consists of a chord together with associated braces the inspection point angle is measured
relative to a saddle location as shown below:

The member local reference x axis is defined as being along the member concerned and is always ori-
entated away from the joint. The local reference y axis is in the same direction as the member local
reference y axis. The local reference z axis forms a right handed set with the member axis and the local
reference y axis. Note that, for consistency, the results are reported in terms of brace in-plane (y local
axis) and out-of-plane (z local axis) bending.

3.5.2. Tubular Butt Joints


Where a joint has no identifiable chord the program adopts a reference system that relates to the
members connected to the joint. This is shown diagrammatically below:

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 37
FATJACK Analysis Methods

The member local reference x axis is defined as being along the member concerned and is always ori-
entated away from the joint. The local reference y axis is in the same direction as the member local
reference y axis. The local reference z axis forms a right handed set with the member axis and the local
reference y axis. Note that, for consistency, the results are reported in terms of brace in-plane (y local
axis) and out-of-plane (z local axis) bending.

3.5.3. Non-Tubular Braces


Non-tubular joints have no associated chord elements and are thus treated in a similar manner to tubular
butt joints. The inspection points are then defined by way of y and z ordinates (or in-plane bending
and out-of-plane bending ordinates to be strictly consistent).

The member local reference x axis is defined as being along the brace concerned and is always orientated
away from the joint. The in-plane axis is in the same direction as the brace local y axis. The out-of-plane
axis forms a right handed set with the brace axis and the in-plane axis.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
38 of ANSYS, Inc. and its subsidiaries and affiliates.
Stress Concentration Factors

3.6. Design Information


By default FATJACK utilizes the geometric and topology information that is stored in the ASAS fatigue
model backing files. This information is used for computing both stress values and stress concentration
factors (where requested).

There may be many instances when the data utilized for the structural analysis is inconsistent with that
required to undertake the fatigue study and FATJACK provides several mechanisms to override the
values that would be adopted by default.

3.6.1. Design Geometry


The geometry information (diameter, thickness, areas, etc) is used both for the SCF computations and
stress evaluation. The default information extracted from the analysis backing files may be overridden
(or augmented) by utilizing the DESIGN command which enables both the section type and properties
to be defined. For non-tubular sections this is essential if sections have not been utilized in the original
analysis in order that the appropriate SCF values may be utilized (see Stress Concentration Factors (p. 39)).

3.6.2. Secondary Elements


Since FATJACK is joint based, all valid elements connected to a joint will be processed. There may be
situations where certain elements are not required for fatigue processing and these may be selectively
deactivated by defining them as secondary elements. Note that the secondary elements are effectively
removed from the joint and thus will not be included in the joint classification and, hence, any automatic
SCF evaluation that may be requested. Similarly secondary members will not be included in any influence
function computations where this is operative (see Influence Functions (p. 40)).

3.7. Stress Concentration Factors


The damage calculations required for a fatigue analysis utilize the hot spot stresses at the inspection
points defined for a given brace. These hot spot stresses are normally determined from the brace
nominal loads (axial force and lateral bending) and associated stress concentration factors for the locations
concerned.

The stress concentration factors (SCFs) may be provided in one or two ways:

Explicit SCF definitions

Utilizing built-in empirical formulations to automatically generate the required SCF values.

An alternative approach to conventional SCF evaluation of hot spot stresses is the use of so-called in-
fluence functions which account for the load distribution at a joint. This method can be requested when
using the Efthymiou equations by including the INFL option.

3.7.1. Explicit SCF Definitions


Where SCF values are known explicitly these may be provided in a number of ways:

For tubular sections use:

SCFJ if crown and saddle SCF values are known; for example, if generated by empirical formulae
by the user.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 39
FATJACK Analysis Methods

SCFA if SCF values are known at specific locations; for example, results of a detailed finite element
joint analysis, or from model tests.

For non-tubular sections use:

SCFB if the SCF values are constant across the section.


SCFP if the SCF values vary according to location.

For all section types a default value may be defined which is associated with a brace element in the
absence of any explicit definitions or computed SCF values. Note that default SCF values are associated
with a section profile (WF, BOX, etc) rather than an element type (BEAM, TUBE).

3.7.2. Empirical SCF Formulations


FATJACK incorporates automatic SCF generation facilities for tubular joints, based upon the following
empirical formulations:

Wordsworth (Ref. 2)

Kuang (Ref. 3)

DS449 (Ref. 10)

Efthymiou (Ref. 11)

These formulations provide SCF values which depend upon the joint classification, load condition, and
position around the brace/chord interface.

This facility enables brace elements at a joint to have SCF values computed at the crown and saddle
locations. To provide increased flexibility in the application of empirical formulae to SCF calculations,
FATJACK includes the ability to utilize different formulations for specific SCF values around a given
brace member. This is achieved by specifying an equation matrix, the constituents of which define the
formula to be adopted for each of the loading components and position. The user can thus utilize the
most appropriate formulations for a given joint type as required by many certification authorities.

Automatic generation of SCF values is requested using the SCF AUTO commands. To provide total
flexibility in the determination of the SCF values, parameter definitions and limits may be modified using
the PARAMETER and LIMIT commands.

The brace side SCF values obtained from the Kuang equations may be modified using the Marshall
Reduction factor if required using the REDUCTION command.

In addition, minimum SCF values may be specified, to provide a lower bound for any computed SCF,
using the SCFM command.

3.7.3. Influence Functions


Conventional SCF formulations assume a certain loading condition in determining the SCF values viz:

Axial loads in K, KT and X joints are assumed balanced

Out-of-plane bending in K and KT joints is assumed unbalanced

Out-of-plane bending in X joints is assumed balanced

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
40 of ANSYS, Inc. and its subsidiaries and affiliates.
Stress Concentration Factors

In-plane bending in K joints is assumed balanced

For simple joints in a framed structure these assumptions are often reasonably valid and will provide
good estimates of the structural behavior. For more complex joints, however, the load paths become
much more ill-defined and it is not possible to easily determine their effects on the hot spot stresses.

The influence function approach automatically accounts for load dependency by not only computing
SCF values which are multiplied by the reference brace, but also generating influence terms which are
multiplied by loading in adjacent braces at the joint in question. The key principle involved in this
methodology is the superposition of linear elastic stress fields which enables a hot spot stress to be
computed from the sum of the contributions from all braces at a joint.

The influence functions derived by Efthymiou (Ref. 11) have been incorporated into FATJACK and are
utilized by including the INFL option in the preliminary data (without this option the conventional SCF
values are computed). At present only planar braces are considered in the influence function computa-
tions, the multiplanar effects considered as being small by comparison.

Note that the SCFM command has no effect on computed influence functions.

For any joints where the Efthymiou equations cannot be (or are not) applied, conventional SCF values
are computed (if requested). It is not currently possible to mix conventional SCFs (either explicitly
defined or computed) with influence functions for a given joint.

3.7.4. SCF Interpolation


Where SCF values are given for the crown and saddle locations, intermediate SCFs are developed by
interpolating the defined values. At present linear interpolation is used.

Note that this normally requires that a non-zero SCF term is given for the in-plane bending term at the
saddle, and the out-of-plane bending term at the crown. For automatically generated terms the following
convention is adopted:

SCFips = SCFipc

SCFopc = SCFops

where:

ips
in-plane bending saddle

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 41
FATJACK Analysis Methods

ipc
in-plane bending crown

opc
out-of-plane bending crown

ops
out-of-plane bending saddle

3.7.5. Annotated SCF File Generation


Since FATJACK is joint based, all valid elements connected to a joint will be processed. There may be
situations where certain elements are not required for fatigue processing and these may be selectively
deactivated by defining them as secondary elements. Note that the secondary elements are effectively
removed from the joint and thus will not be included in the joint classification and, hence, any automatic
SCF evaluation that may be requested. Similarly secondary members will not be included in any influence
function computations where this is operative (see Influence Functions (p. 40)).

Example 3.1: Example Generated SCF File


*
* JOINT 1420
* CHORD 1001
* CONNECTING BRACES 151 1101
*
SCFJ 1420 151 BRAC 7.23 7.23 3.78 3.78 10.47 10.47 * K JOINT E E E E E E
SCFJ 1420 151 CHOR 9.15 9.15 4.44 4.44 13.04 13.04 * E E E E E E
SCFJ 1420 1101 BRAC 2.40 2.40 2.89 2.89 5.58 5.58 * K JOINT E E E E E E
SCFJ 1420 1101 CHOR 3.81 3.81 2.40 2.40 6.95 6.95 * E E E E E E
*
* JOINT 1520
* CHORD 1005
* CONNECTING BRACES 141 152 122 121
*
SCFJ 1520 141 BRAC 2.15 15.82 4.05 4.05 12.33 12.33 * T JOINT E E E E E E
SCFJ 1520 141 CHOR 5.65 24.07 5.41 5.41 17.33 17.33 * E E E E E E
SCFJ 1520 152 BRAC 2.05 13.90 3.78 3.78 10.95 10.95 * Y JOINT E E E E E E
SCFJ 1520 152 CHOR 4.51 18.56 4.44 4.44 13.64 13.64 * E E E E E E
SCFJ 1520 122 BRAC 1.41 27.97 4.67 4.67 16.99 16.99 * X JOINT E= E+ E+ E+ E+ E+
SCFJ 1520 122 CHOR 5.42 71.29 9.20 9.20 37.25 37.25 * E+ E+ E+ E+ E+ E+
SCFJ 1520 121 BRAC 1.41 27.97 4.67 4.67 16.99 16.99 * X JOINT E= E+ E+ E+ E+ E+
SCFJ 1520 121 CHOR 5.42 71.29 9.20 9.20 37.25 37.25 * E+ E+ E+ E+ E+ E+
*
* JOINT 2330
* CHORD 0
* CONNECTING BRACES 906 905 225 226 205
*
SCFJ 2330 906 BRAC 1.00 1.00 1.00 1.00 1.00 1.00 * UN JOINT
SCFJ 2330 906 CHOR 1.00 1.00 1.00 1.00 1.00 1.00 *
SCFJ 2330 905 BRAC 1.00 1.00 1.00 1.00 1.00 1.00 * UN JOINT
SCFJ 2330 905 CHOR 1.00 1.00 1.00 1.00 1.00 1.00 *
SCFJ 2330 225 BRAC 1.00 1.00 1.00 1.00 1.00 1.00 * UN JOINT
SCFJ 2330 225 CHOR 1.00 1.00 1.00 1.00 1.00 1.00 *
SCFJ 2330 226 BRAC 1.00 1.00 1.00 1.00 1.00 1.00 * UN JOINT
SCFJ 2330 226 CHOR 1.00 1.00 1.00 1.00 1.00 1.00 *
SCFJ 2330 205 BRAC 1.00 1.00 1.00 1.00 1.00 1.00 * UNJOINT
SCFJ 2330 205 CHOR 1.00 1.00 1.00 1.00 1.00 1.00 *

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
42 of ANSYS, Inc. and its subsidiaries and affiliates.
Element Cross Sections

The annotation after each SCFJ command corresponds to the following convention:

SCFJ joint brace BRAC scf values (6) *a joint type equation (6)
a
SCFJ joint brace CHOR scf values (6) * equation (6)
a
equation (6)

where equation (i) is the requested empirical formulation identifier (W, K, D, E) for the printed scf value
(i).

The equation (i) is optionally followed by + or =. If + is printed this signifies that one or more parameters
were exceeded for the given location and the value corresponding to the computed parameters are
reported. If = is printed this signifies that one or more parameters were exceeded for the given location,
and the value corresponding to the limiting parameters are reported.

3.8. S-N Curves


S-N curves relate stress range information (S) to number of cycles to failure (N). Basic design curves
consist of linear or bi-linear relationships between log (S) and log (N). FATJACK enables S-N data to be
defined by reference to a library of S-N design curves from various recognized sources viz:

Department of Energy T curve


Department of Energy F2 curve
American Petroleum Institute X curve
American Petroleum Institute X curve
Danish Standard DS449 tubular joint curve

Other curves may be defined explicitly by providing an ordinate on the curve and associated slope.
Multi-linear curves are supported, as are curves with a cut-off stress below which no damage occurs.

Thickness correction may be applied to the S-N curves to account for varying plate thickness. This cor-
rection (requested using the THIC command) has the effect of shifting the S-N curves to reduce the fatigue
strength with increasing thickness. The correction makes

3.9. Units
FATJACK requires that UNITS are defined for any dimensional input data to FATJACK itself.

Note, however, that the geometric angular data unit defaults to degrees, and wave frequencies are always
defined in Hertz.

The user must ensure that they are consistent with the units adopted in the structural model.

If local modified input data units are required, this is achieved by specifying one or more UNITS com-
mands within the main body of the FATJACK data thus permitting a combination of unit systems
within the one data file (see UNITS command).

The results units cannot be modified since they are dimensionless or are in non-standard units.

3.10. Element Cross Sections


Any design data provided (using the DESI command) will overwrite the section information. Likewise,
for non-tubular sections, use of the INSP SYMM, INSP POSN or SCFPOINT commands will replace the
section data.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 43
FATJACK Analysis Methods

3.11. Results presentation


Results can be viewed within the Mechanical application if using a Design Assessment system with the
FATJACK Assessment Type. By default the results will also be output to a text file of the same name as
the input file, having the .out extension. The type and format of the results to be presented in this
file is determined using the PRINT command. A number of options exist that permit a wide variety of
information to be reported with as much or as little detail as required. These are set based upon input
data if using FATJACK through a Design Assessment system.

Results can also be obtained dynamically as described in the following sections:


3.11.1. Obtaining Results
3.11.2. FATJACK Results

3.11.1. Obtaining Results


FATJACK results can be brought into Excel using a custom plugin or can be accessed through Python
functions. See Accessing Results using Excel in the Mechanical BEAMST User's Manual and Accessing
Results using Python in the Mechanical BEAMST User's Manual for more information.

3.11.2. FATJACK Results


The results saved by FATJACK are dependent on the type of fatigue analysis carried out and the options
selected for the run. This section discusses the following types of results:
3.11.2.1. Fatigue Usage Factor Results
3.11.2.2. Damage per Wave Results
3.11.2.3. Stress Range Results
3.11.2.4. Stress Histogram Results

3.11.2.1. Fatigue Usage Factor Results


Fatigue usage factor results are stored under results type FATJACK USAGE. The results are stored on a
number of surfaces, with each surface representing an inspection point. The results are stored as element
results on result set 1 and subset 0. Results components are as tabulated below. Components marked
* are stored as character strings:

RESULTS COM- DESCRIPTION


PONENT
NO.INSPP No of inspection points
INSP.PNT Inspection point number
CHORD1 First chord number
CHORD2 Second chord number
JT.TYPE Joint type *
CHD/BRC Chord/brace *
S-N S-N table name *
FAIL Failure flag *
CHOR.DIA Chord diameter
CHOR.THK Chord thickness
CHOR.LEN Chord length

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
44 of ANSYS, Inc. and its subsidiaries and affiliates.
Results presentation

RESULTS COM- DESCRIPTION


PONENT
CHOR.FIX Chord fixity
BRAC.DIA Brace diameter
BRAC.THK Brace thickness
INSET Inset (TUBE)
ANGLE Inspection point angle (TUBE)
Y-COOR Y coordinate of point on section (non-TUBE)
Z-COOR Z coordinate of point on section (non-TUBE)
SCF.AXBR Brace axial SCF
SCF.IPBR Brace in-plane SCF
SCF.OPBR Brace out-of-plane SCF
SCF.AXCH usChord axial SCF
SCF.IPCH Chord in-plane SCF
SCF.OPCH Chord out-of-plane SCF
USAGE Usage factor
LIFE Fatigue life

3.11.2.2. Damage per Wave Results


If print option DAMW was selected in the FATJACK run then the following additional information is
stored under results type DAMAGE PER WAVE. The results are stored as element results on result set
LC and sub-set 0. For spectral analysis, LC = IWVSPC, where IWVSPC is the spectrum number (1 IWVSPC
NSPEC) and NSPEC is the number of spectra. For all other analysis types, LC =ICASE, where ICASE is
the user wave case number.

RESULTS COM- DESCRIPTION


PONENT
JOINT Joint number
BRACE Brace number
WAVE Wave number
CHD/BRC Chord/brace *
ANGLE Inspection point angle (TUBE elements)
DAMAGE Damage per wave
Y-COOR Inspection point Y coord (BEAM elements)
Z-COOR Inspection point Z coord (BEAM elements)

3.11.2.3. Stress Range Results


These results are saved if options PEAK or RNGE are specified in the FATJACK data. If utilization factors
have been requested then stress utilization factors will be saved.

Results will be stored under one of the following results types as appropriate:

SIGNED PEAK STRESS

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 45
FATJACK Analysis Methods

PEAK STRESS UTILS

STRESS RANGE

STRESS RANGE UTILS

The results are stored as element results on result set 1 and sub-set IDETM, where IDETM is the system
deterministic case number (1 IDETM NDETM) and NDETM is the number of deterministic cases.

The results are stored as element results on results set LC and sub set 0, where LC is the user wave case
number.

Results components are as tabulated below. Components marked * are stored as character strings:

RESULTS COM- DESCRIPTION


PONENT
JOINT Joint number
BRACE Brace number
WAVE Wave number
CHD/BRC Chord/brace *
ANGLE Inspection point angle (TUBE elements)
Y-COOR Inspection point Y coord (BEAM elements)
Z-COOR Inspection point Z coord (BEAM elements)
STRESS Signed peak stress or stress range
UTILS Utilization factor

3.11.2.4. Stress Histogram Results


If option OCRW is specified in a spectral fatigue job, the following element results are saved under
result type OCCUR EACH WAVE. The results are stored on result set IWVSPC and sub-set ISUB, where
IWVSPC is the spectrum number (1 IWVSPC NSPEC) and NSPEC is the number of spectra, ISUB = 1
for brace side results, and ISUB = 2 for chord side results (if they are also stored).

Components marked + are stored on a per interval basis and require an interval to be entered as the
result position when obtaining the values via the function axlgetelementex.

RESULTS COMPON- DESCRIPTION


ENT
NO.WAVE Number of spectra
WAVE Spectrum number
NO.TRFUN Number of transfer functions
TR.FUNC Transfer function number
NO.INTVL Number of intervals
ANGLE Inspection point angle
+
OCURENCE Occurrence for stress range interval 1

If option OCRT is specified in a spectral fatigue job, the following element results are saved under results
type OCCUR EACH TRANSFER. The results are stored on result set ITRANS and sub-set ISUB, where ITRANS

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
46 of ANSYS, Inc. and its subsidiaries and affiliates.
Results presentation

is the user transfer function number, ISUB=1 for brace side results, and ISUB = 2 for chord side results
(if they are also stored).

Components marked + are stored on a per interval basis and require an interval to be entered as the
result position when obtaining the values via the function axlgetelementex.

RESULTS COMPON- DESCRIPTION


ENT
NO.TRFUN Number of transfer functions
TR.FUNC Transfer function number
NO.INTVL Number of intervals
ANGLE Inspection point angle
+
OCURENCE Occurrence for stress range interval 1

If option OCRT is specified in a spectral fatigue job, the following element results are saved under result
type RANGE HISTOGRAM. The results are stored on result set 1 and sub-set ISUB. For brace side results,
ISUB=1. For chord side results (if they are also stored), ISUB=2.

Components marked + are stored on a per interval basis and require an interval to be entered as the
result position when obtaining the values via the function axlgetelementex.

RESULTS COMPON- DESCRIPTION


ENT
NO.WAVE Number of spectra
NO.TRFUN Number of transfer functions
NO.INTVL Number of intervals
ANGLE Inspection point angle
TOTAL Total occurrence
+
STRESS Stress range for interval 1
+
OCURENCE Occurrence for stress range interval 1

If option OCUR is specified in a time history fatigue job, the following element results are saved under
result type RANGE HISTOGRAM. The results are stored on result set LC and sub-set ISUB, where LC is
the user time history case number, ISUB=1 for brace side results, and ISUB = 2 for chord side results (if
they are also stored).

Components marked + are stored on a per interval basis and require an interval to be entered as the
result position when obtaining the values via the function axlgetelementex.

RESULTS COMPON- DESCRIPTION


ENT
NO.WAVE Number of time histories
WAVE Time history number
NO.INTVL Number of intervals
ANGLE Inspection point angle (TUBE elements)
Y-COOR Inspection point Y coord (BEAM elements)
Z-COOR Inspection point Z coord (BEAM elements)

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 47
FATJACK Analysis Methods

RESULTS COMPON- DESCRIPTION


ENT
STRESS+ Stress range for interval 1
+
OCURENCE Occurrence for stress range interval 1

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
48 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 4: FATJACK Command Reference
The data for FATJACK consists of a set of commands which indicate the type of calculation to be per-
formed and the content of the output. The basic data structure is as follows:

Except for stress and time history calculations, FATJACK expects each load condition to consist of a pair
of loadcases representing the real and imaginary parts of the applied cyclic loading. Mechanical APDL
automatically outputs pairs of loadcases if the harmonic option is selected. The term wave case is used
in the FATJACK data description to indicate which pair of cases is being referred to. For example, wave
case 2 refers to the 2nd wave analyzed using the harmonic option or the 3rd and 4th loadcase from a
static analysis.

For stress history analyses a wave case may generate any number of loadcases. For time history analyses,
a wave history case refers to the analysis results obtained for a specific wave condition. The details of
the commands required for each analysis type are given in the following sections.

4.1. FATJACK Free Format Syntax


This section discusses the following topics:
4.1.1. General Description
4.1.2. Special Symbols

4.1.1. General Description


The input data for FATJACK are specified according to syntax diagrams similar to that shown below.
The conventions adopted are described in the following pages. Detailed descriptions of each of the
data items can be found in the remainder of this chapter.

Each data item consists as follows

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 49
FATJACK Command Reference

Each horizontal branch represents a possible input instruction. Input instructions are composed of
keywords (shown in UPPER-CASE), numerical values or alphanumerics (shown in lower-case) and
special symbols. Each item in the list is separated from each other by a comma or one or more blank
spaces.

An input line must not be longer than 80 characters.

Numerical values have to be given in one of two forms:

i. If an integer is specified, a decimal point must not be supplied.

ii. If a real value is specified, the decimal point may be omitted if the value is a whole number.

Exponent formats may be utilized where real numbers are required. For example, the following are
equivalent:

0.004

4.0E-3

4.0D-3

Similarly, the following have the same value:

410.0

410

4.10E2

Alphanumerics are any non-numeric strings, which may include the letters A-Z, numbers 0-9, and the
characters +, -, / and :. The letters A-Z may be supplied in either uppercase or lowercase, but no distinc-
tion is made between the uppercase and lowercase form. Hence A is assumed identical with a, B
with b and so on. For example, the following are all permissible alphanumeric strings:

CASE

STR1 END

3mm

Similarly, the following are all identical strings:

COMB

Comb

comb

Alphanumeric strings must not include any special symbols (See Special Symbols (p. 51)).

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
50 of ANSYS, Inc. and its subsidiaries and affiliates.
FATJACK Free Format Syntax

If certain lines are optional, these are shown by an arrow which bypasses the line(s):

In order to build up a block of data, a line or a series of lines may need to be repeated until the complete
set has been defined. This is shown by an arrow which loops back:

If certain data items within a command line are optional, these are shown by an arrow which bypasses
the appropriate item:

Some data lines require an integer or real list to be input whose length is variable. This is shown by a
horizontal arrow around the list variable(s):

Where one or more possible alternative items may appear in the list, these are shown by separate
branches for each:

4.1.2. Special Symbols


The following is a list of characters which have a special significance to the FATJACK input:

* An asterisk is used to define the beginning of a comment, whatever follows on the


line will not be interpreted. It may appear anywhere on the line, any preceding data
will be processed as normal. For example:

* THIS IS A COMMENT FOR THE WHOLE LINE


CASE 4 2.7 * THIS IS A COMMENT FOR PART OF A LINE

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 51
FATJACK Command Reference

' Single quotes are used to enclose some text strings which could contain otherwise
inadmissible characters. The quotes are placed at each end of the string. They may
also be used to provide in-line comments between data items on a given line. For
example:

STRUCTURE As used for design study STRU


, A comma or one or more consecutive blanks will act as a delimiter between items
in the line.

For example, 5, 10, 15 is the same as 5 10 15

Note that two commas together signify that an item has been omitted. This may
be permissible for certain data blocks.

For example: 5,, 15 is the same as 5 0 15

Unless otherwise stated in the section describing the data block, omitted numer-
ical values are zero.
: A colon at the start of the line signifies that the line is a continuation from the previ-
ous line.

For example

5
: 10
: 15
is the same as 5 10 15
@ A command @filename may appear anywhere in a data file. When such a command
is encountered, the input of data switches to the file filename and data continues to
be read from that file until either the end-of-file is reached or an @ command is en-
countered in the secondary file.

When the end of the secondary file is reached, that file is closed and input
switches back to the previous data file. If, however, an @ command is found in
the secondary file, input switches to yet another file. This process can continue
until a maximum of 5 secondary files are open simultaneously.

For example

@prelim.dat
@wave.dat
@design.dat
@scf.dat
@spectral.dat

design.dat might then contain the lines

@type.dat
@desi.dat
@gap.dat
@chord.dat

finally

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
52 of ANSYS, Inc. and its subsidiaries and affiliates.
FATJACK Priority of Data Assignments

type.dat contains the joint designation data


desi.dat contains the design geometry data
etc

4.2. FATJACK Priority of Data Assignments


There are a number of commands that allow element and element step data to be assigned in terms
of element, group or property numbers. These appear in the command syntax diagrams in the following
format:

The priority of such assignments is defined below:

Element data - use element data assigned to individual elements (ELEM)

if none - use element data assigned to the group the element belongs to (GROU)

if none - use element data assigned to the property integer used by the element (PROP)

if none - no element data assigned to element.

Step data - use step data assigned to individual elements (ELEM)

if none - use step data assigned to the group the element belongs to (GROU)

if none - use step data assigned to the property integer used by the element (PROP)

if none - use element data assigned to individual elements (ELEM)

if none - use element data assigned to the group the element belongs to (GROU)

if none - use element data assigned to the property integer used by the element (PROP)

if none - no step data assigned to element.

Element and step data assignment is not order dependant. This is demonstrated by the following example:
COMMand .... data1 ELEM 1
COMMand .... data2 GROU 5
COMMand .... data3 ELEM 2
COMMand .... data4 PROP 1

Assuming elements 1 and 2 are in group 5:

Element 1 has data1 assigned

Element 2 has data3 assigned

All other elements in group 5 have data 2 assigned

All elements with property integer 1, except elements 1 and 2 and elements in group 5, have data4 assigned.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 53
FATJACK Command Reference

It should be noted that when step data is explicitly being defined it overrides any element assignments
even if the step data is assigned to a group or property and the element data assigned to an individual
element. Thus in the following example:
COMMand .... data1 STEP 2 GROU 5
COMMand .... data2 STEP 2 PROP 1
COMMand .... data3 ELEM 1
COMMand .... data4 STEP 2 ELEM 2

Step 2 of element 1 has data1 assigned because the group assignment overrides the property assignment.
In this instance the step specific group assignment also overrides the element assignment which is not
step specific.

Step 2 of element 2 has data4 assigned.

Step 2 of all other elements in group 5 have data1 assigned.

Step 2 of all elements with property integer 1, except those in group 5, have data2 assigned.

All steps, except step 2, of element 1 have data3 assigned.

No data is assigned to any steps, other than step 2, for any elements other than element 1.

Note also that if a command is assigned more than once to a given element, group or property, a
warning will be issued and the last defined value, or values, adopted.

4.3. Preliminary Data


The preliminary data is the first block of the FATJACK data. It defines the memory size to be used, the
project name, structure and component names, file names and options to be used. It also defines which
files are to be saved for further processing.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
54 of ANSYS, Inc. and its subsidiaries and affiliates.
Fatigue Analysis method

The preliminary data must contain at least a JOB, STRUCTURE and END command. Other commands
should be used as appropriate.

4.4. Fatigue Analysis method


This section discusses the following topics:
4.4.1. ANALYSIS command
4.4.2. Deterministic Analysis
4.4.3. Spectral Analysis
4.4.4. Stress History Analysis
4.4.5.Time History Analysis

4.4.1. ANALYSIS command


The ANALYSIS command selects the method of analysis to be utilized. This command must immediately
follow the preliminary data.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 55
FATJACK Command Reference

Parameters

ANALYSIS
Keyword

DETERMINISTIC
Keyword to select a deterministic analysis.

SPECTRAL
Keyword to select a spectral fatigue analysis.

STRESS HISTORY
Keyword to select a stress history analysis.

Notes

1. One of these analysis type keywords must appear as the first line after the preliminary data.

2. The analysis type determines the valid commands that may be utilized within the input data file. The
following sections Deterministic Analysis (p. 56) to Time History Analysis (p. 69) summarize the available
commands for each type of analysis.

Examples
ANALYSIS SPECTRAL
ANALYSIS STRESS

4.4.2. Deterministic Analysis


This type of analysis requires two sets of data:

Target fatigue life (YEAR). Computed lives below this figure will be reported as having failed.

Wave occurrence data in the form of number of occurrences per year (DETE). This data may either explicitly
reference waves that have been analyzed; that is, referred to in the WAVE data, or may consist of wave
height occurrences, in which case interpolation is carried out to obtain member forces for wave heights
that have not been analyzed. This second approach permits a limited number of waves to be structurally
analyzed whilst providing a much more detailed fatigue definition.

Deterministic Commands

Command Description Usage Note


ANALYSIS DE- Selects deterministic analysis method C
TERMINISTIC

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
56 of ANSYS, Inc. and its subsidiaries and affiliates.
Fatigue Analysis method

Command Description Usage Note


JOINT Selects joints at which fatigue lives are calcu- C
lated
WAVE Specifies wave information from analysis C 1
CHORD Chord elements at a joint 2
DESIGN Modified section properties for elements
GAP Gap dimensions for specific braces at a joint
GAPDEFAULT Default gap dimension
INSET Inset distance for moment backoff
SECONDARY Secondary elements to be ignored in checks
TYPE Joint definition and classification
INSPECTION Inspection point selection
LIMITS SCF empirical equation limits modification
PARAMETER SCF empirical parameter modification
REDUCTION Requests Marshall Reduction 3
SCF TUB DE- Default SCF value C 4
FAULT
Default SCF value C 4
SCF RHS DE-
FAULT Default SCF value C 4

SCF WF DE- Default SCF value C 4


FAULT

SCF BOX DE-


FAULT
SCF AUTO Default SCF equations to be used in genera-
DEFAULT tion
SCF AUTO SCF equations to be used at specific joints
JOINT
SCFANGLE SCF values at specific inspection points on
tubular braces
SCFBRACE User defined SCF values for non-tubular
braces
SCFJOINT User defined saddle and crown SCFs
SCFMINIMUM Minimum SCF values
SCFPOINT SCF values at specific inspection points on
non-tubular braces
THICKNESS Requests S-N thickness correction
CURVE User defined S-N damage curve definition
DETE Wave occurrence data C
S-N S-N curve assignment C
YEAR Target fatigue life C
PRINT Report options 5

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 57
FATJACK Command Reference

Command Description Usage Note


STOP Terminates data input C

Usage

C
Compulsory command, but see notes below where applicable.

Notes

1. This data can be generated by FATJACK using the WAVE AUTO command provided the wave loading
was generated using the Mechanical application.

2. Whilst not compulsory it is recommended that a default gap is specified. In the absence of such a com-
mand, braces forming a K or KT configuration will have the gap computed unless specific GAP data is
supplied. This may result in incorrect SCF calculations at joints with simplified modelling.

3. The Marshall Reduction factor is only applicable to SCF values generated using the Kuang equations.

4. The SCF DEFAULT command must be supplied for each section type that is to be processed.

5. In the absence of a PRINT command a detailed report will be produced.

4.4.2.1. Deterministic Analysis Example


The data has the following characteristics:

New structure defined

Time history results retrieved from multiple structures

Time history occurrence specified with probabilities

Stress range intervals for cycle counting computed automatically

Example 4.1: Example of Deterministic Analysis Data File


SYSTEM DATA AREA 200000
PROJECT FATD
JOB POST
FILES JACD
STRUCTURE JACD
TITLE FATJACK USER MANUAL EXAMPLE
OPTIONS GOON NODL NOBL PRNO
UNITS KN M
END
ANALYSIS DETERMINISTIC
SCF TUBE DEFA 1.0 1.0 1.0 1.0 1.0 1.0
*USE GENERIC DEFINITION FOR SCF EQUATIONS
SCF AUTO JOINT EFTHYMIOU
: 1110 2210 1120 1210 1520 2130 1420 1130 1540 1140 1150 1440
: 1310 1350 2330 1330 2520 2540 2110 2120 3130 3210 2420 2140 2150 2440 3250
: 2310 2350 3350 3310 3420 3440 3110 3120 4130 3520 4210 3540 3140 3150 4250
: 3330 4330 4110 4150 4310 4350 2250 1250
WAVE AUTO
*THE FOLLOWING JOINTS ARE CONNECTED TO AN ELEMENT
JOIN 1110 2210 1120 1210 1520 2130 1420 1130 1540 1140 1150 1440 1250 2250
: 1310 1350 2330 1330 2520 2540 2110 2120 3130 3210 2420 2140 2150 2440 3250
: 2310 2350 3350 3310 3420 3440 3110 3120 4130 3520 4210 3540 3140 3150 4250
: 3330 4330 4110 4150 4310 4350
SECO ELEM 1505 1506 1509 504 1510 503 514 513 524 523 1401 825 1201 1203 827

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
58 of ANSYS, Inc. and its subsidiaries and affiliates.
Fatigue Analysis method

: 1402 1204 1501 1202 1502 1503 1504


*
*EXPLICIT DEFINITION OF K JOINT AND ASSOCIATED CHORD
CHORD 1330 105 106 LENGTH 20.0 FIX 0.7
TYPE 1330 K 125 126
GAP1330125 126 -0.03 THRU 125
*USER DEFINED SN CURVE WITH THICKNESS CORRECTION, REQUIRES BASE THICKNESS
*TO BE SPECIFIED
UNITS N MM
CURV USR1 MULT 45.0 1.0E7 3.56
: 45.0 1.0E7 4.56
: THICK 20.0
S-N USR1 ELEM ALL
THICK
UNITS KN M
DETE HEIGHT 699458 1.0 0.0 DAF 1.6
DETE HEIGHT 685279 1.0 45.0 DAF 1.6
DETE HEIGHT 615024 1.0 90.0 DAF 1.6
DETE HEIGHT 568370 1.0 135.0 DAF 1.6
DETE HEIGHT 180369 2.0 0.0 DAF 1.5
DETE HEIGHT 167805 2.0 45.0 DAF 1.5
DETE HEIGHT 167650 2.0 90.0 DAF 1.5
DETE HEIGHT 156061 2.0 135.0 DAF 1.5
DETE HEIGHT 46512 3.0 0.0 DAF 1.45
DETE HEIGHT 41091 3.0 45.0 DAF 1.45
DETE HEIGHT 45700 3.0 90.0 DAF 1.45
DETE HEIGHT 42851 3.0 135.0 DAF 1.45
DETE HEIGHT 11994 4.0 0.0 DAF 1.38
DETE HEIGHT 10062 4.0 45.0 DAF 1.38
DETE HEIGHT 12458 4.0 90.0 DAF 1.38
DETE HEIGHT 11766 4.0 135.0 DAF 1.38
DETE HEIGHT 3093 5.0 0.0 DAF 1.32
DETE HEIGHT 2464 5.0 45.0 DAF 1.32
DETE HEIGHT 3396 5.0 90.0 DAF 1.32
DETE HEIGHT 3231 5.0 135.0 DAF 1.32
DETE HEIGHT 798 6.0 0.0 DAF 1.25
DETE HEIGHT 603 6.0 45.0 DAF 1.25
DETE HEIGHT 926 6.0 90.0 DAF 1.25
DETE HEIGHT 887 6.0 135.0 DAF 1.25
DETE HEIGHT 206 7.0 0.0 DAF 1.2
DETE HEIGHT 148 7.0 45.0 DAF 1.2
DETE HEIGHT 252 7.0 90.0 DAF 1.2
DETE HEIGHT 244 7.0 135.0 DAF 1.2
DETE HEIGHT 53 8.0 0.0 DAF 1.15
DETE HEIGHT 36 8.0 45.0 DAF 1.15
DETE HEIGHT 69 8.0 90.0 DAF 1.15
DETE HEIGHT 67 8.0 135.0 DAF 1.15
DETE HEIGHT 14 9.0 0.0 DAF 1.10
DETE HEIGHT 9 9.0 45.0 DAF 1.10
DETE HEIGHT 19 9.0 90.0 DAF 1.10
DETE HEIGHT 18 9.0 135.0 DAF 1.10
DETE HEIGHT 4 10.0 0.0 DAF 1.05
DETE HEIGHT 2 10.0 45.0 DAF 1.05
DETE HEIGHT 5 10.0 90.0 DAF 1.05
DETE HEIGHT 5 10.0 135.0 DAF 1.05
DETE HEIGHT 1 11.0 0.0 DAF 1.01
DETE HEIGHT 1 11.0 45.0 DAF 1.01
DETE HEIGHT 1 11.0 90.0 DAF 1.01
DETE HEIGHT 1 11.0 135.0 DAF 1.01
DETE HEIGHT 0 12.0 0.0
DETE HEIGHT 0 12.0 45.0
DETE HEIGHT 0 12.0 90.0
DETE HEIGHT 0 12.0 135.0
YEAR 50.0
PRIN XCHE DETA USAG SUMM SCFE
STOP

4.4.3. Spectral Analysis


This type of analysis requires three compulsory sets of data and two optional sets:

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 59
FATJACK Command Reference

Target fatigue life (YEAR). Computed lives below this figure will be reported as having failed. This is
compulsory.

Transfer function definition. It is normal to assign all the analyzed waves for a given direction to a partic-
ular transfer function. This is achieved using the TRANSFER command which also permits dynamic ampli-
fication factors to be applied. This is compulsory.

Sea state spectra definition. For each transfer function a series of sea state spectra are defined using the
SPECTRUM command. A variety of spectra are available viz:

Scott-Weigel
JONSWAP
Pierson-Moskowitz
Ochi-Hubble

Each spectrum is associated with a probability of occurrence. This command is compulsory.

Wave spreading effects may be included using the SPREAD command. Three spreading functions are
available including those associated with Mitsuyasu (Ref. 8) and Goda (Ref. 9). This command is optional.

Additional frequencies may be defined at which the transfer function is to be computed. This permits a
limited number of waves to be structurally analyzed whilst providing a more detailed fatigue definition
and is particularly suitable for structures that respond linearly to increasing wave heights. This command
is optional.

Table 4.1: Spectral Commands

Command Description Usage Note


ANALYSIS SPEC- Selects spectral analysis method C
TRAL
JOINT Selects joints at which fatigue lives are calculated C
WAVE Specifies wave information from analysis C 1
CHORD Chord elements at a joint 2
DESIGN Modified section properties for elements
GAP Gap dimensions for specific braces at a joint
GAPDEFAULT Default gap dimension
INSET Inset distance for moment backoff
SECONDARY Secondary elements to be ignored in checks
TYPE Joint definition and classification
INSPECTION Inspection point selection
LIMITS SCF empirical equation limits modification
PARAMETER SCF empirical parameter modification
REDUCTION Requests Marshall Reduction 3
SCF TUB DEFAULT Default SCF value C 4
SCF RHS DEFAULT Default SCF value C 4
SCF WF DEFAULT Default SCF value C 4
SCF BOX DE- Default SCF value C 4
FAULT

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
60 of ANSYS, Inc. and its subsidiaries and affiliates.
Fatigue Analysis method

Command Description Usage Note


SCF AUTO DE- Default SCF equations to be used in generation
FAULT
SCF AUTO JOINT SCF equations to be used at specific joints
SCFANGLE SCF values at specific inspection points on tubular braces
SCFBRACE User defined SCF values for non-tubular braces
SCFJOINT User defined saddle and crown SCFs
SCFMINIMUM Minimum SCF values
SCFPOINT SCF values at specific inspection points on non-tubular
braces
THICKNESS Requests S-N thickness correction
ACCE Gravitational acceleration term
CURVE S-N damage curve definition
FREQUENCY Additional interpolated frequencies
S-N User defined S-N curve assignment C 5
SIGM Stress histogram information C 6
SPECTRUM Wave spectrum probabilities C
SPREADING Requests wave spreading
TRANSFER Transfer function data C
YEAR Target fatigue life C
PRINT Report options 7
STOP Terminates data input C

Usage

C
Compulsory command, but see notes below where applicable.

Notes

1. This data can be generated by FATJACK using the WAVE AUTO command provided the wave loading
was generated using the Mechanical application.

2. Whilst not compulsory it is recommended that a default gap is specified. In the absence of such a com-
mand, braces forming a K or KT configuration will have the gap computed unless specific GAP data is
supplied. This may result in incorrect SCF calculations at joints with simplified modelling.

3. The Marshall Reduction factor is only applicable to SCF values generated using the Kuang equations.

4. The SCF DEFAULT command must be supplied for each section type that is to be processed.

5. S-N data does not have to be supplied if a stress histogram report has been requested using the PRINT
command.

6. Stress histogram information is only required if requested using the PRINT command.

7. In the absence of a PRINT command a detailed report will be produced.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 61
FATJACK Command Reference

4.4.3.1. Spectral Analysis Example


The data has the following characteristics:

Automatic wave information recovery

Explicit SCF definitions using @ file facility

Secondary elements

Design data for leg members

Utilizes built in S-N curve with thickness correction and user defined power

Four sea-states

Example 4.2: Example of Spectral Analysis Data File


WAVE AUTO
*THE FOLLOWING JOINTS ARE CONNECTED TO AN ELEMENT
JOIN 1110 2210 1120 1210 1520 2130 1420 1130 1540 1140 1150 1440 1250 2250
: 1310 1350 2330 1330 2520 2540 2110 2120 3130 3210 2420 2140 2150 2440 3250
: 2310 2350 3350 3310 3420 3440 3110 3120 4130 3520 4210 3540 3140 3150 4250
: 3330 4330 4110 4150 4310 4350
*DEFINE DESIGN PROPERTIES FOR LEG MEMBERS
DESIGN.PROPERTIES TUB 2.4 0.05 GROUP 8
SECO ELEM 1505 1506 1509 504 1510 503 514 513 524 523 1401 825 1201 1203 827
: 1402 1204 1501 1202 1502 1503 1504
S-N APXD ELEM ALL
THICKNESS.CORRECTION 0.25 *POWER SET TO 0.25 INSTEAD OF DEFAULT 0.3
TRAN 100 1 1.0030 2 1.0119 3 1.0215 4 1.0340 5 1.0496 6 1.0689
TRAN 100 7 1.0919 8 1.1197 9 1.1850 10 1.2726 11 1.3607 12 1.4718
SPEC 100 PMOS 0.25 2.5 0.1121
SPEC 100 PMOS 0.25 3.5 1.4573
SPEC 100 PMOS 0.25 4.5 2.6904
SPEC 100 PMOS 0.25 5.5 1.6815
SPEC 100 PMOS 0.25 6.5 0.5605
SPEC 100 PMOS 0.25 7.5 0.1121
SPEC 100 PMOS 0.75 2.5 0.3363
SPEC 100 PMOS 0.75 3.5 8.5196
SPEC 100 PMOS 0.75 4.5 11.7705
SPEC 100 PMOS 0.75 5.5 7.6228
SPEC 100 PMOS 0.75 6.5 3.363
SPEC 100 PMOS 0.75 7.5 0.5605
SPEC 100 PMOS 1.25 3.5 4.9324
SPEC 100 PMOS 1.25 4.5 11.6584
SPEC 100 PMOS 1.25 5.5 9.7527
SPEC 100 PMOS 1.25 6.5 4.9324
SPEC 100 PMOS 1.25 7.5 1.2331
SPEC 100 PMOS 1.25 8.5 0.1121
SPEC 100 PMOS 1.75 3.5 0.5605
SPEC 100 PMOS 1.75 4.5 5.7171
SPEC 100 PMOS 1.75 5.5 7.7349
SPEC 100 PMOS 1.75 6.5 4.2598
SPEC 100 PMOS 1.75 7.5 1.3452
SPEC 100 PMOS 1.75 8.5 0.1121
SPEC 100 PMOS 2.25 4.5 1.7936
SPEC 100 PMOS 2.25 5.5 4.8203
SPEC 100 PMOS 2.25 6.5 3.2509
SPEC 100 PMOS 2.25 7.5 1.0089
SPEC 100 PMOS 2.25 8.5 0.1121
SPEC 100 PMOS 2.75 4.5 0.2242
SPEC 100 PMOS 2.75 5.5 1.9057
SPEC 100 PMOS 2.75 6.5 2.242
SPEC 100 PMOS 2.75 7.5 0.7847
SPEC 100 PMOS 2.75 8.5 0.1121
SPEC 100 PMOS 3.25 5.5 0.5605
SPEC 100 PMOS 3.25 6.5 1.2331

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
62 of ANSYS, Inc. and its subsidiaries and affiliates.
Fatigue Analysis method

SPEC 100 PMOS 3.25 7.5 0.5605


SPEC 100 PMOS 3.25 8.5 0.1121
SPEC 100 PMOS 3.75 5.5 0.1121
SPEC 100 PMOS 3.75 6.5 0.4484
SPEC 100 PMOS 3.75 7.5 0.3363
SPEC 100 PMOS 3.75 8.5 0.1121
SPEC 100 PMOS 4.25 6.5 0.1121
SPEC 100 PMOS 4.25 7.5 0.2242
SPEC 100 PMOS 4.25 8.5 0.1121
SPEC 100 PMOS 4.75 7.5 0.1121
SPEC 100 PMOS 4.75 8.5 0.1121
SPEC 100 PMOS 5.25 8.5 0.1121
TRAN 200 13 1.0030 14 1.0119 15 1.0215 16 1.0340 17 1.0496 18 1.0689
TRAN 200 19 1.0919 20 1.1197 21 1.1850 22 1.2726 23 1.3607 24 1.4718
SPEC 200 PMOS 0.25 2.5 0.1413
SPEC 200 PMOS 0.25 3.5 1.8369
SPEC 200 PMOS 0.25 4.5 3.3912
SPEC 200 PMOS 0.25 5.5 2.1195
SPEC 200 PMOS 0.25 6.5 0.7065
SPEC 200 PMOS 0.25 7.5 0.1413
SPEC 200 PMOS 0.75 2.5 0.4239
SPEC 200 PMOS 0.75 3.5 10.7388
SPEC 200 PMOS 0.75 4.5 14.8365
SPEC 200 PMOS 0.75 5.5 9.6084
SPEC 200 PMOS 0.75 6.5 4.239
SPEC 200 PMOS 0.75 7.5 0.7065
SPEC 200 PMOS 1.25 3.5 6.2172
SPEC 200 PMOS 1.25 4.5 14.6952
SPEC 200 PMOS 1.25 5.5 12.2931
SPEC 200 PMOS 1.25 6.5 6.2172
SPEC 200 PMOS 1.25 7.5 1.5543
SPEC 200 PMOS 1.25 8.5 0.1413
SPEC 200 PMOS 1.75 3.5 0.7065
SPEC 200 PMOS 1.75 4.5 7.2063
SPEC 200 PMOS 1.75 5.5 9.7497
SPEC 200 PMOS 1.75 6.5 5.3694
SPEC 200 PMOS 1.75 7.5 1.6956
SPEC 200 PMOS 1.75 8.5 0.1413
SPEC 200 PMOS 2.25 4.5 2.2608
SPEC 200 PMOS 2.25 5.5 6.0759
SPEC 200 PMOS 2.25 6.5 4.0977
SPEC 200 PMOS 2.25 7.5 1.2717
SPEC 200 PMOS 2.25 8.5 0.1413
SPEC 200 PMOS 2.75 4.5 0.2826
SPEC 200 PMOS 2.75 5.5 2.4021
SPEC 200 PMOS 2.75 6.5 2.826
SPEC 200 PMOS 2.75 7.5 0.9891
SPEC 200 PMOS 2.75 8.5 0.1413
SPEC 200 PMOS 3.25 5.5 0.7065
SPEC 200 PMOS 3.25 6.5 1.5543
SPEC 200 PMOS 3.25 7.5 0.7065
SPEC 200 PMOS 3.25 8.5 0.1413
SPEC 200 PMOS 3.75 5.5 0.1413
SPEC 200 PMOS 3.75 6.5 0.5652
SPEC 200 PMOS 3.75 7.5 0.4239
SPEC 200 PMOS 3.75 8.5 0.1413
SPEC 200 PMOS 4.25 6.5 0.1413
SPEC 200 PMOS 4.25 7.5 0.2826
SPEC 200 PMOS 4.25 8.5 0.1413
SPEC 200 PMOS 4.75 7.5 0.1413
SPEC 200 PMOS 4.75 8.5 0.1413
SPEC 200 PMOS 5.25 8.5 0.1413
TRAN 300 25 1.0030 26 1.0119 27 1.0215 28 1.0340 29 1.0496 30 1.0689
TRAN 300 31 1.0919 32 1.1197 33 1.1850 34 1.2726 35 1.3607 36 1.4718
SPEC 300 PMOS 0.25 2.5 0.1973
SPEC 300 PMOS 0.25 3.5 2.5649
SPEC 300 PMOS 0.25 4.5 4.7352
SPEC 300 PMOS 0.25 5.5 2.9595
SPEC 300 PMOS 0.25 6.5 0.9865
SPEC 300 PMOS 0.25 7.5 0.1973
SPEC 300 PMOS 0.75 2.5 0.5919
SPEC 300 PMOS 0.75 3.5 14.9948

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 63
FATJACK Command Reference

SPEC 300 PMOS 0.75 4.5 20.7165


SPEC 300 PMOS 0.75 5.5 13.4164
SPEC 300 PMOS 0.75 6.5 5.919
SPEC 300 PMOS 0.75 7.5 0.9865
SPEC 300 PMOS 1.25 3.5 8.6812
SPEC 300 PMOS 1.25 4.5 20.5192
SPEC 300 PMOS 1.25 5.5 17.1651
SPEC 300 PMOS 1.25 6.5 8.6812
SPEC 300 PMOS 1.25 7.5 2.1703
SPEC 300 PMOS 1.25 8.5 0.1973
SPEC 300 PMOS 1.75 3.5 0.9865
SPEC 300 PMOS 1.75 4.5 10.0623
SPEC 300 PMOS 1.75 5.5 13.6137
SPEC 300 PMOS 1.75 6.5 7.4974
SPEC 300 PMOS 1.75 7.5 2.3676
SPEC 300 PMOS 1.75 8.5 0.1973
SPEC 300 PMOS 2.25 4.5 3.1568
SPEC 300 PMOS 2.25 5.5 8.4839
SPEC 300 PMOS 2.25 6.5 5.7217
SPEC 300 PMOS 2.25 7.5 1.7757
SPEC 300 PMOS 2.25 8.5 0.1973
SPEC 300 PMOS 2.75 4.5 0.3946
SPEC 300 PMOS 2.75 5.5 3.3541
SPEC 300 PMOS 2.75 6.5 3.946
SPEC 300 PMOS 2.75 7.5 1.3811
SPEC 300 PMOS 2.75 8.5 0.1973
SPEC 300 PMOS 3.25 5.5 0.9865
SPEC 300 PMOS 3.25 6.5 2.1703
SPEC 300 PMOS 3.25 7.5 0.9865
SPEC 300 PMOS 3.25 8.5 0.1973
SPEC 300 PMOS 3.75 5.5 0.1973
SPEC 300 PMOS 3.75 6.5 0.7892
SPEC 300 PMOS 3.75 7.5 0.5919
SPEC 300 PMOS 3.75 8.5 0.1973
SPEC 300 PMOS 4.25 6.5 0.1973
SPEC 300 PMOS 4.25 7.5 0.3946
SPEC 300 PMOS 4.25 8.5 0.1973
SPEC 300 PMOS 4.75 7.5 0.1973
SPEC 300 PMOS 4.75 8.5 0.1973
SPEC 300 PMOS 5.25 8.5 0.1973
TRAN 400 37 1.0030 38 1.0119 39 1.0215 40 1.0340 41 1.0496 42 1.0689
TRAN 400 43 1.0919 44 1.1197 45 1.1850 46 1.2726 47 1.3607 48 1.4718
SPEC 400 PMOS 0.25 2.5 0.1189
SPEC 400 PMOS 0.25 3.5 1.5457
SPEC 400 PMOS 0.25 4.5 2.8536
SPEC 400 PMOS 0.25 5.5 1.7835
SPEC 400 PMOS 0.25 6.5 0.5945
SPEC 400 PMOS 0.25 7.5 0.1189
SPEC 400 PMOS 0.75 2.5 0.3567
SPEC 400 PMOS 0.75 3.5 9.0364
SPEC 400 PMOS 0.75 4.5 12.4845
SPEC 400 PMOS 0.75 5.5 8.0852
SPEC 400 PMOS 0.75 6.5 3.567
SPEC 400 PMOS 0.75 7.5 0.5945
SPEC 400 PMOS 1.25 3.5 5.2316
SPEC 400 PMOS 1.25 4.5 12.3656
SPEC 400 PMOS 1.25 5.5 10.3443
SPEC 400 PMOS 1.25 6.5 5.2316
SPEC 400 PMOS 1.25 7.5 1.3079
SPEC 400 PMOS 1.25 8.5 0.1189
SPEC 400 PMOS 1.75 3.5 0.5945
SPEC 400 PMOS 1.75 4.5 6.0639
SPEC 400 PMOS 1.75 5.5 8.2041
SPEC 400 PMOS 1.75 6.5 4.5182
SPEC 400 PMOS 1.75 7.5 1.4268
SPEC 400 PMOS 1.75 8.5 0.1189
SPEC 400 PMOS 2.25 4.5 1.9024
SPEC 400 PMOS 2.25 5.5 5.1127
SPEC 400 PMOS 2.25 6.5 3.4481
SPEC 400 PMOS 2.25 7.5 1.0701
SPEC 400 PMOS 2.25 8.5 0.1189
SPEC 400 PMOS 2.75 4.5 0.2378

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
64 of ANSYS, Inc. and its subsidiaries and affiliates.
Fatigue Analysis method

SPEC 400 PMOS 2.75 5.5 2.0213


SPEC 400 PMOS 2.75 6.5 2.378
SPEC 400 PMOS 2.75 7.5 0.8323
SPEC 400 PMOS 2.75 8.5 0.1189
SPEC 400 PMOS 3.25 5.5 0.5945
SPEC 400 PMOS 3.25 6.5 1.3079
SPEC 400 PMOS 3.25 7.5 0.5945
SPEC 400 PMOS 3.25 8.5 0.1189
SPEC 400 PMOS 3.75 5.5 0.1189
SPEC 400 PMOS 3.75 6.5 0.4756
SPEC 400 PMOS 3.75 7.5 0.3567
SPEC 400 PMOS 3.75 8.5 0.1189
SPEC 400 PMOS 4.25 6.5 0.1189
SPEC 400 PMOS 4.25 7.5 0.2378
SPEC 400 PMOS 4.25 8.5 0.1189
SPEC 400 PMOS 4.75 7.5 0.1189
SPEC 400 PMOS 4.75 8.5 0.1189
SPEC 400 PMOS 5.25 8.5 0.1189
YEAR 50.0
PRIN XCHE DETA USAG SUMM SCFE
STOP

4.4.4. Stress History Analysis


This type of analysis requires two sets of data:

Target fatigue life (YEAR). Computed lives below this figure will be reported as having failed.

Wave occurrence data in the form of number of occurrences per year (DETM). This data may either explicitly
reference waves that have been analyzed; that is, referred to in the WAVE data, or may consist of wave
height occurrences, in which case interpolation is carried out to obtain member forces for wave heights
that have not been analyzed. This second approach permits a limited number of waves to be structurally
analyzed whilst providing a much more detailed fatigue definition.

Table 4.2: Stress History Commands

Command Description Usage Note


ANALYSIS Selects stress history analysis method C
STRESS HIS-
TORY
JOINT Selects joints at which fatigue lives are calculated C
WAVE Specifies wave information from analysis C 1
CHORD Chord elements at a joint 2
DESIGN Modified section properties for elements
GAP Gap dimensions for specific braces at a joint
GAPDEFAULT Default gap dimension
INSET Inset distance for moment backoff
SECONDARY Secondary elements to be ignored in checks
TYPE Joint definition and classification
INSPECTION Inspection point selection
LIMITS SCF empirical equation limits modification
PARAMETER SCF empirical parameter modification
REDUCTION Requests Marshall Reduction 3

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 65
FATJACK Command Reference

Command Description Usage Note


SCF TUB DE- Default SCF value C 4
FAULT
SCF RHS DE- Default SCF value C 4
FAULT
SCF WF DE- Default SCF value C 4
FAULT
SCF BOX DE- Default SCF value C 4
FAULT
SCF AUTO DE- Default SCF equations to be used in generation
FAULT
SCF AUTO SCF equations to be used at specific joints
JOINT
SCFANGLE SCF values at specific inspection points on tubular braces
SCFBRACE User defined SCF values for non-tubular braces
SCFJOINT User defined saddle and crown SCFs
SCFMINIMUM Minimum SCF values
SCFPOINT SCF values at specific inspection points on non-tubular
braces
THICKNESS Requests S-N thickness correction
ALLOWABLE Allowable stress
CURVE User defined S-N damage curve definition C 5
DETE Wave occurrence data C
S-N S-N curve assignment C 6
YEAR Target fatigue life C
PRINT Report options 7
STOP Terminates data input C

Usage

C
Compulsory command, but see notes below where applicable.

Notes

1. This data can be generated by FATJACK using the WAVE AUTO command provided the wave loading
was generated using the Mechanical application.

2. Whilst not compulsory it is recommended that a default gap is specified. In the absence of such a com-
mand, braces forming a K or KT configuration will have the gap computed unless specific GAP data is
supplied. This may result in incorrect SCF calculations at joints with simplified modelling.

3. The Marshall Reduction factor is only applicable to SCF values generated using the Kuang equations.

4. The SCF DEFAULT command must be supplied for each section type that is to be processed.

5. S-N data does not have to be supplied if a stress histogram report has been requested using the PRINT
command.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
66 of ANSYS, Inc. and its subsidiaries and affiliates.
Fatigue Analysis method

6. Stress histogram information is only required if requested using the PRINT command.

7. In the absence of a PRINT command a detailed report will be produced.

4.4.4.1. Stress History Analysis Example


The data has the following characteristics:

Explicit wave information defined

Automatic generation of influence functions

Secondary elements

Utilizes built in S-N curve with thickness correction

Analyses wave occurrence definition

Example 4.3: Example of Stress History Analysis Data File


SYSTEM DATA AREA 200000
PROJECT FATI
JOB POST
FILES JACF
TITLE FATJACK USER MANUAL EXAMPLE
OPTIONS NODL NOBL PRNO DATA GOON INFL
UNITS KN M
END
ANALYSIS STRESS HISTORY
SCF TUBE DEFAULT 1.0 1.0 1.0 1.0 1.0 1.0
SCF AUTOMATIC DEFAULT GENERAL EFTHYMIOU
SCF AUTOMATIC JOINT
: 1110 2210 1120 1210 1520 2130 1420 1130 1540 1140 1150 1440
: 1310 1350 2330 1330 2520 2540 2110 2120 3130 3210 2420 2140 2150 2440 3250
: 2310 2350 3350 3310 3420 3440 3110 3120 4130 3520 4210 3540 3140 3150 4250
: 3330 4330 4110 4150 4310 4350 2250 1250
WAVE 1 1.0 5.0 0.0 NPOS 6
WAVE 2 2.0 6.2 0.0 NPOS 6
WAVE 3 3.0 7.1 0.0 NPOS 6
WAVE 4 4.0 7.7 0.0 NPOS 6
WAVE 5 5.0 8.2 0.0 NPOS 6
WAVE 6 6.0 8.7 0.0 NPOS 6
WAVE 7 7.0 9.1 0.0 NPOS 6
WAVE 8 8.0 9.5 0.0 NPOS 6
WAVE 9 9.0 9.8 0.0 NPOS 6
WAVE 10 10.0 10.2 0.0 NPOS 6
WAVE 11 11.0 10.6 0.0 NPOS 6
WAVE 12 12.0 11.0 0.0 NPOS 6
WAVE 13 1.0 5.0 90.0 NPOS 6
WAVE 14 2.0 6.2 90.0 NPOS 6
WAVE 15 3.0 7.1 90.0 NPOS 6
WAVE 16 4.0 7.7 90.0 NPOS 6
WAVE 17 5.0 8.2 90.0 NPOS 6
WAVE 18 6.0 8.7 90.0 NPOS 6
WAVE 19 7.0 9.1 90.0 NPOS 6
WAVE 20 8.0 9.5 90.0 NPOS 6
WAVE 21 9.0 9.8 90.0 NPOS 6
WAVE 22 10.0 10.2 90.0 NPOS 6
WAVE 23 11.0 10.6 90.0 NPOS 6
WAVE 24 12.0 11.0 90.0 NPOS 6
WAVE 25 1.0 5.0 45.0 NPOS 6
WAVE 26 2.0 6.2 45.0 NPOS 6
WAVE 27 3.0 7.1 45.0 NPOS 6
WAVE 28 4.0 7.7 45.0 NPOS 6
WAVE 29 5.0 8.2 45.0 NPOS 6
WAVE 30 6.0 8.7 45.0 NPOS 6
WAVE 31 7.0 9.1 45.0 NPOS 6

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 67
FATJACK Command Reference

WAVE 32 8.0 9.5 45.0 NPOS 6


WAVE 33 9.0 9.8 45.0 NPOS 6
WAVE 34 10.0 10.2 45.0 NPOS 6
WAVE 35 11.0 10.6 45.0 NPOS 6
WAVE 36 12.0 11.0 45.0 NPOS 6
WAVE 37 1.0 5.0 135.0 NPOS 6
WAVE 38 2.0 6.2 135.0 NPOS 6
WAVE 39 3.0 7.1 135.0 NPOS 6
WAVE 40 4.0 7.7 135.0 NPOS 6
WAVE 41 5.0 8.2 135.0 NPOS 6
WAVE 42 6.0 8.7 135.0 NPOS 6
WAVE 43 7.0 9.1 135.0 NPOS 6
WAVE 44 8.0 9.5 135.0 NPOS 6
WAVE 45 9.0 9.8 135.0 NPOS 6
WAVE 46 10.0 10.2 135.0 NPOS 6
WAVE 47 11.0 10.6 135.0 NPOS 6
WAVE 48 12.0 11.0 135.0 NPOS 6
*THE FOLLOWING JOINTS ARE CONNECTED TO AN ELEMENT
JOINT 1110 2210 1120 1210 1520 2130 1420 1130 1540 1140 1150 1440 1250 2250
: 1310 1350 2330 1330 2520 2540 2110 2120 3130 3210 2420 2140 2150 2440 3250
: 2310 2350 3350 3310 3420 3440 3110 3120 4130 3520 4210 3540 3140 3150 4250
: 3330 4330 4110 4150 4310 4350
SECONDARY ELEMENTS 1505 1506 1509 504 1510 503 514
: 513 524 523 1401 825 1201 1203 827
: 1402 1204 1501 1202 1502 1503 1504
S-N DET ELEM ALL
THICKNESS.CORRECTION
DETERMINISTIC.DATA 1 699458
DETERMINISTIC.DATA 2 180369
DETERMINISTIC.DATA 3 46512
DETERMINISTIC.DATA 4 11994
DETERMINISTIC.DATA 5 3093
DETERMINISTIC.DATA 6 798
DETERMINISTIC.DATA 7 206
DETERMINISTIC.DATA 8 53
DETERMINISTIC.DATA 9 14
DETERMINISTIC.DATA 10 4
DETERMINISTIC.DATA 11 1
DETERMINISTIC.DATA 12 0
DETERMINISTIC.DATA 13 615024
DETERMINISTIC.DATA 14 167650
DETERMINISTIC.DATA 15 45700
DETERMINISTIC.DATA 16 12457
DETERMINISTIC.DATA 17 3396
DETERMINISTIC.DATA 18 926
DETERMINISTIC.DATA 19 252
DETERMINISTIC.DATA 20 69
DETERMINISTIC.DATA 21 19
DETERMINISTIC.DATA 22 5
DETERMINISTIC.DATA 23 1
DETERMINISTIC.DATA 24 0
DETERMINISTIC.DATA 25 685279
DETERMINISTIC.DATA 26 167805
DETERMINISTIC.DATA 27 41091
DETERMINISTIC.DATA 28 10062
DETERMINISTIC.DATA 29 2464
DETERMINISTIC.DATA 30 603
DETERMINISTIC.DATA 31 148
DETERMINISTIC.DATA 32 36
DETERMINISTIC.DATA 33 9
DETERMINISTIC.DATA 34 2
DETERMINISTIC.DATA 35 1
DETERMINISTIC.DATA 36 0
DETERMINISTIC.DATA 37 568370
DETERMINISTIC.DATA 38 156061
DETERMINISTIC.DATA 39 42851
DETERMINISTIC.DATA 40 11766
DETERMINISTIC.DATA 41 3231
DETERMINISTIC.DATA 42 887
DETERMINISTIC.DATA 43 244
DETERMINISTIC.DATA 44 67
DETERMINISTIC.DATA 45 18

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
68 of ANSYS, Inc. and its subsidiaries and affiliates.
Fatigue Analysis method

DETERMINISTIC.DATA 46 5
DETERMINISTIC.DATA 47 1
DETERMINISTIC.DATA 48 0
YEAR 50.0
PRIN XCHE DETA USAG SUMM SCFE
STOP

4.4.5. Time History Analysis


This type of analysis requires three sets of data:

Target fatigue life (YEAR). Computed lives below this figure will be reported as having failed.

Occurrence data of the time histories defined in the HIST data in the form of occurrences per year (DETE).

Rainflow counting data (CYCLE)

Table 4.3: Time History Commands

Command Description Usage Note


ANALYSIS Selects time history analysis method C
TIME HIS-
TORY
JOINT Selects joints at which fatigue lives are calculated C
HIST Specifies time history information from analysis C
CHORD Chord elements at a joint 1
DESIGN Modified section properties for elements
GAP Gap dimensions for specific braces at a joint
GAPDE- Default gap dimension
FAULT
INSET Inset distance for moment backoff
SECONDARY Secondary elements to be ignored in checks
TYPE Joint definition and classification
INSPECTION Inspection point selection
LIMITS SCF empirical equation limits modification
PARAMETER SCF empirical parameter modification
REDUCTION Requests Marshall Reduction 2
SCF TUB DE- Default SCF value C 3
FAULT
SCF RHS DE- Default SCF value C 3
FAULT
SCF WF DE- Default SCF value C 3
FAULT
SCF BOX DE- Default SCF value C 3
FAULT
SCF AUTO Default SCF equations to be used in generation
DEFAULT
SCF AUTO SCF equations to be used at specific joints
JOINT

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 69
FATJACK Command Reference

Command Description Usage Note


SCFANGLE SCF values at specific inspection points on tubular braces
SCFBRACE User defined SCF values for non-tubular braces
SCFJOINT User defined saddle and crown SCFs
SCFMINIM- Minimum SCF values
UM
SCFPOINT SCF values at specific inspection points on non-tubular
braces
THICKNESS Requests S-N thickness correction
CURVE User defined S-N damage curve definition
CYCLE Rainflow counting data C
DETE Wave occurrence data C
S-N S-N curve assignment C
YEAR Target fatigue life C
PRINT Report options 4
STOP Terminates data input C

Usage

C
Compulsory command, but see notes below where applicable.

Notes

1. Whilst not compulsory it is recommended that a default gap is specified. In the absence of such a com-
mand, braces forming a K or KT configuration will have the gap computed unless specific GAP data is
supplied. This may result in incorrect SCF calculations at joints with simplified modelling.

2. The Marshall Reduction factor is only applicable to SCF values generated using the Kuang equations.

3. The SCF DEFAULT command must be supplied for each section type that is to be processed.

4. In the absence of a PRINT command a detailed report will be produced.

4.4.5.1. Time History Analysis Example


The data has the following characteristics:

New structure defined

Time history results retrieved from multiple structures

Time history occurrence specified with probabilities

Stress range intervals for cycle counting computed automatically

Example 4.4: Example of Time History Analysis Data File


JOB POST
PROJECT T206
STRUCTURE A206
NEWSTRUCTURE N206

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
70 of ANSYS, Inc. and its subsidiaries and affiliates.
ACCE

TITLE FATJACK USER MANUAL EXAMPLE


OPTIONS GOON END
UNITS KN M
END
ANALYSIS TIME HISTORY
HIST 1 A206 80 880
HIST 2 B206 80 880
HIST 3 C206 80 880
HIST 11 D206 80 880
HIST 12 E206 80 880
HIST 13 F206 80 880
HIST 21 G206 80 880
HIST 22 H206 80 880
HIST 23 I206 80 880
JOIN 2 5 7
INSP 8 ELEM ALL
SCF TUBE DEFA 3.0
SCF AUTO DEFA K K K K W K K K W
SCF AUTO DEFA KT K K K W K K K W
SCF AUTO JOIN 2 5 7
CURV USER SINGLE 35.0E3 1.0E7 3.0
S-N USER ELEM ALL
GAPD WORD 0.05
GAPD KUAN 0.05
YEAR 30.0
DETE 21 PROB 200
DETE 22 PROB 100.0
DETE 23 PROB 100
DETE 11 PROB 200
DETE 12 PROB 60.0
DETE 13 PROB 40.0
DETE 1 PROB 50
DETE 2 PROB 30.0
DETE 3 PROB 20.0
CYCLE 20
PRINT FULL DETAILED SCFP SCFE USAGE XCHE
STOP

4.5. ACCE
The ACCE command defines the value for gravitational acceleration required for spectral fatigue analysis.

Parameters

ACCE
Keyword

gravity
Gravitational acceleration (Real).

Notes

1. This command is optional for a SPECTRAL analysis. If not defined the program will adopt a value of 9.81
metres/sec2 (converted into the appropriate analysis units). If required the default value may be overwritten
using the ACCE command.

2. If used, the command should be defined only once.

Examples

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 71
FATJACK Command Reference

ACCE 32.2

4.6. ALLOWABLE
The ALLOWABLE command is used to request that the computed stress value from a Stress History
Analysis is compared with a target (limit) value when PRINT PEAK or PRINT RNGE is also requested. If
the command is used FATJACK will report a utilization factor rather than a direct stress.

Parameters

ALLOWABLE: Keyword.
value: Allowable stress to the actual stress (PEAK or RNGE) is compared. (Real).

Notes

1. This command is optional for a STRESS HISTORY analysis.

4.7. ANSYS
The ANSYS command defines the name of the Mechanical APDL job(s) from which the analysis results
will be obtained.

The ANSYS command is a preliminary command, and should only appear at the head of the
FATJACK data set.

Parameters

ANSYS
Keyword

FNAME
Keyword to denote that the job names are specified in a job name list file (Optional).

Jobname

without FNAME job name of the Mechanical APDL model to be processed. This is the name associated
with the .RST file generated by Mechanical APDL (Alphanumeric, up to 32 characters).

with FNAME name of file containing paths and names of Mechanical APDL jobs to be included in
the analysis together.

youngs
Young's Modulus (Optional, Real).

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
72 of ANSYS, Inc. and its subsidiaries and affiliates.
CHORD

density
Material density (Optional, Real).

Usage

The command is mandatory if FATJACK is to be performed following a Mechanical APDL analysis and
must be omitted otherwise.

Notes

1. FATJACK will only process certain Mechanical APDL beam element types in a Mechanical APDL model.
Valid element names are:

BEAM44, BEAM188, BEAM189, PIPE16, PIPE59, PIPE288, PIPE289

Examples

1. The Mechanical APDL analysis is a single job called ANSYSJOB. All the load cases in this job will be analyzed
in FATJACK.
ANSYS ANSYSJOB

2. The Mechanical APDL analysis information is contained in a job name file called Ansysfile.txt, which
references three Mechanical APDL jobs called Ansysjob1, Ansysjob2 and Ansysjob3 located in different
directories.
ANSYS FNAME Ansysfile.txt

The contents of file Ansysfile.txt are:

C:\AnsysAnalysis\Job1\Ansysjob1

C:\AnsysAnalysis\Job2\Ansysjob2

C:\AnsysAnalysis\Job3\Ansysjob3

4.8. CHORD
The CHORD command allows specific elements to be defined as chord members at a particular joint.
Optional chord lengths and end fixity may also be defined if required.

Parameters

CHORD
Keyword

joint
Joint number at which the chord is being defined (Integer).

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 73
FATJACK Command Reference

member
User element number defining a segment of the chord associated with the specified joint. If computed
chord lengths are required then all the members defining the chord must be supplied (Integer).

LENGTH
Keyword to indicate that the chord length is to follow.

length
Length of the chord to be used in SCF computations. (Real).

FIXITY
Keyword to indicate that the chord end fixity parameter is to follow.

para
Chord end fixity parameter used in the computation of SCF values using Efthymiou equations. (Real).

Usage

This command is compulsory if joints modelled with two or three nodes points are required.

Notes

1. For joints modelled with a single node, this command is optional and the criteria for selecting chord
elements are described below. In cases where the chord member is segmented, however, it is suggested
that a chord command is supplied in order that the correct chord length is utilized in any automated
SCF computations.

i. Select all tubes at the current node with largest diameter.

ii. From those selected in (i), select all tubes with largest thickness.

iii. If the list selected in (ii), contains only one element then this becomes the chord.

iv. If the list selected in (ii), contains more than one element then the list is checked for a pair of co-linear
elements forming a through member. If only one pair is found then these elements for the chord.

v. If no unique chord element(s) can be found then automatic SCF calculation is not possible. In these
circumstances, the chord element(s) must be defined manually.

vi. The chord length is computed as 2/3 of the combined lengths of the chosen chords. The chord end
fixity parameter is set to 0.7.

2. If K or KT joints are to be modelled with more than one node, a chord command must be supplied to
provide the connectivity information between the nodes at the joint. For KT joints modelled with three
nodes, the joint number must be the central node and the chord elements must connect the three braces
together (See the TYPE command).

3. If not defined, the chord length is computed as 2/3 of the combined lengths of the selected chord ele-
ments.

4. If not defined, the chord end fixity parameter is set to 0.7.

A value of 0.5 represents fixed end conditions.

A value of 1.0 represents pin end conditions.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
74 of ANSYS, Inc. and its subsidiaries and affiliates.
CURVE

Examples
CHOR 2000 2010 2020 2030 2040
CHOR 10 110 120 LENG 20.0
CHOR 105 1150 1250 FIX 0.8
CHOR 20 120 LENG 18.5 FIX 0.7

4.9. COMPONENT
The COMPONENT command is used to define the component to be processed from a substructure
analysis.

The COMP command is a preliminary command, and should only appear at the head of the FATJACK
data set.

Parameters

COMPONENT
Keyword

sname
Structure name identifying which existing structure is to be accessed from the current project, see the
PROJ command (Alphanumeric, 4 characters, the first character must be alphabetic).

tree
This is the path down the component tree from the given structure in sname to the component which
is being used for the FATJACK processing.

Usage

Valid only, and compulsory, for recovered components.

Notes

1. If the user is processing the global structure run in a substructure analysis, use only the STRU command.

Examples

To process the second level component CMP2, part of assembled component CMP1, which in turn is
part of structure STRU:
COMP STRU CMP1 CMP2

4.10. CURVE
The CURVE command defines the relationship between stress range and number of cycles to failure
used in computing the damage contribution of the applied wave loading.

Standard curves available within FATJACK do not need to be defined unless non-standard base
thicknesses are required for thickness correction.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 75
FATJACK Command Reference

4.10.1. CURVE Command (User defined S-N curves)

Parameters

CURVE
Keyword

name
Alphanumeric identifier to be associated with this curve (up to 4 characters).

SINGLE
Keyword to denote a single slope curve is being defined.

MULTI
Keyword to denote a multi-linear curve is being defined.

LIMIT
Keyword to denote a single slope curve with a cut-off stress is being defined.

stress, cycle
Point lying on a given section of the S-N curve. For multi-linear curves the point must correspond to the
intersect within the adjacent section. For limiting curves the point must correspond to the cut-off position
(Real).

slope
Slope of a given section of the S-N curve (Real).

THICK
Keyword to indicate that a base thickness is to be provided.

base
Base thickness to be used if thickness correction requested (Real).

Notes

1. The requirement for the ordinates of user defined multi-linear S-N curves to be at the intersection of
adjacent sections is that two pairs of ordinates will be the same, but with differing slopes. This can be
seen in the internal representations of DET and DEF2 design curves (which are both bi-linear).

2. The base thickness is used when thickness correction of the S-N curve is requested (using the THICKNESS
command). For user defined curves a base thickness must be provided if the correction is to be applied.

Examples
CURV DOC LIMIT 32.0 2.0D8 3.56
CURV DSC MULTI 73.0 1.0D7 3.56
: 73.0 1.0D7 4.56

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
76 of ANSYS, Inc. and its subsidiaries and affiliates.
CURVE

4.10.2. CURVE Command (Base thickness definition for standard curves)

Parameters

CURVE
Keyword

curve
Predefined S-N curve name. Only required when base thickness is to be modified from the default value.
The following curves are currently available:

DET, DEF2 Department of Energy T and F2 curves


APX, APXD API RP2A X and X curves
DOT Danish Offshore Regulations DS412 tubular
curve

THICK
Keyword to indicate that a base thickness is to be provided.

base
Base thickness to be used if thickness correction requested (Real).

Note

1. The built in design curves equate to the following S-N definitions.

Curve TYPE Stress Cycle Slope Default Base Thickness


2
(N/mm )
DET MULTI 52.63404 1.0D7 3.0 32mm

52.63404 1.0D7 5.0


DEF2 MULTI 35.05366 1.0D7 3.0 22mm

35.05366 1.0D7 5.0


APX LIMIT 34.94451 2.0D8 4.38 25mm
APXD LIMIT 23.06045 2.0D8 3.74 16mm
DOT LIMIT 33.81812 2.0D8 4.1 N/A (see note 2)

Although the above curves are given in N and mm, any user entries are in data input units.

2. The base thickness is used when thickness correction of the S-N curve is requested (using the THICKNESS
command). For the predefined curves (with the exception of the DOT curve) a default base thickness is
adopted unless otherwise overridden by the user. For the DOT curve, no default base thickness is available
and a user defined value must be provided if thickness correction is required.

Example

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 77
FATJACK Command Reference

CURV DET THICK 30.0

4.11. CYCLE
The CYCLE command defines the number and sizes of the stress range intervals for rainflow counting.

Parameters

CYCLE
Keyword

nint
Number of intervals to sample stress range (Integer, >0).

sigmax
Peak stress range required. If zero or not specified, the peak is determined automatically from the stress
time history (Real, >=0.0).

sig1
Stress range limit for the first interval (Real, >=0.0).

Usage

Mandatory for time history analysis.

Notes

1. If sigmax and sig1 are both specified, sigmax must be larger than sig1.

2. If sig1 is not specified, the nint intervals will be set equally between zero and sigmax or the program
determined peak value if this is not defined.

3. If sig1 is specified, the first stress range interval will be taken as between zero and sig1. The rest (nint-1)
intervals will be set equally between sig1 and sigmax or the program determined peak value if this is
not defined.

Examples
CYCLE 50
CYCLE 50 10.0E6 1.0E6

If you had a number of stress ranges counted, say: 1.1, 1.9, 3.1, 4.4, 9

If you use CYCLE 3 10.5, then you would get counting results with the following:

0 3.5 :3
3.5 - 7.0 :1
7.0 - 10.5 :1

If you use CYCLE 3 then you would get counting results with the following:

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
78 of ANSYS, Inc. and its subsidiaries and affiliates.
DESIGN

03 :2
3-6 :2
6-9 :1

If you use CYCLE 3 10 2, then you would get counting results with the following:

02 :2
2-6 :2
6 - 10 :1

4.12. DESIGN
The DESI command enables geometric properties from the structural analysis to be overridden to account
for design requirements. The design properties are used for computing member stresses and SCF values.
In the absence of any design data the geometric information from the analysis will be adopted.

Parameters

DESIGN
Keyword

type
Section type (Alphanumeric). Valid profiles are:

TUB
Tube

WF
Doubly symmetric Rolled I-section (for example, UB, UC, Joist,WFC, WF)

RHS
Rectangular Hollow Section (RHS)

BOX
Fabricated Box Section

values
Values defining the section dimensions appropriate to the section type. See Section Profile Informa-
tion (p. 125) for details (Real).

STEP
Keyword to indicate the step number is to follow.

istep
Step number for non-prismatic elements. Values should either be 1 or the last step number for the ele-
ment. Alternatively the keywords END1 or END2 may replace STEP istep.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 79
FATJACK Command Reference

ELEMENT
Keyword to denote selection by element numbers.

GROUP
Keyword to denote selection by element group numbers.

PROPERTY
Keyword to denote selection by geometric property integer.

list
List of user element, group or geometric property numbers for which this data is to be assigned. The
list may include the keyword TO but not ALL.

Notes

1. Non-tubular sections must not be applied to TUBE elements.

2. If a step reference is given only that step for the elements specified within the element, group or property
list will be assigned the new section data.

3. See FATJACK Priority of Data Assignments (p. 53) for order of priority for ELEMENT/GROUP/PROPERTY
lists.

4. If insets are defined for the end of a brace, any design properties defined for the same end will be applied
at the inset position.

Examples
DESI TUB 2.0 0.04 ELEM 100 TO 110
DESI TUB 1.5 0.032 END1 ELEM 1010
DESI BOX 2.0 1.5 0.04 0.032

4.13. DETE
The DETE command defines the wave occurrence data required for deterministic and stress history
analyses. Facilities exist to include additional wave definitions that were not included in the wave ana-
lysis. This command is also required in time history analysis to define the occurrence of each time history
case.

Parameters

DETE
Keyword

case
Wave case number to which this occurrence data relates (Integer).

ncycle
Number of cycles per year for this wave case (Integer).

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
80 of ANSYS, Inc. and its subsidiaries and affiliates.
DETE

HEIGHT
Keyword to denote that the occurrence data is to be given in terms of a reference height for a given
direction.

height
Reference wave height (Real).

direction
Reference wave direction (Real, degrees).

DAF
Keyword to denote that the occurrence data is to be given as probability.

daf
Dynamic amplification factor.

PROB
Keyword to denote that the occurrence data is to be given as probability.

pval
Occurrence probability of the wave history case (Real, >+0.0).

Notes

1. For wave cases generated using the WAVE AUTO command, these are numbered sequentially from 1.

2. If the dynamic amplification factor keyword and value are not supplied, unity is assumed. The dynamic
amplification factor data is always ignored in the time history analyses.

3. The use of occurrence data relating to reference wave height provides a flexible means to develop the
occurrence data without use of wave case numbers and permitting additional wave height data to be
defined that were not previously analyzed.

For a given wave direction each height defined on a DETE command is related to the associated
analyzed wave cases for the same wave direction.

Stress values for the reference wave height are obtained by linear interpolation between adjacent
wave heights. Stresses for reference wave heights which are below the lower limit of the analyzed
wave cases will be obtained by factoring the limit value.

Stresses for reference wave heights which are above the upper limit of the analyzed wave cases will
be obtained by linear extrapolation of the last two cases. This is shown diagrammatically below.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 81
FATJACK Command Reference

Using this facility, all wave occurrence data may be defined by reference to the wave height, thus
obviating the need to refer to an analyzed wave case number.

4. The reference height option is not applicable to time history analyses.

5. Keyword PROB is only allowed in time history analyses. However if it is specified, then it must be used
for all DETE commands. The units in which the probability is input are immaterial providing that they
are consistent throughout. The program computes a true probability for each history by dividing each
input probability by the sum of all the probabilities.

Examples
DETE 1 150000
DETE 2 124500 DAF 1.05

DETE HEIG 150000 3.5 0.0


DETE HEIG 124500 6.0 0.0 DAF 1.10

DETE 1 PROB 1000.0


DETE 2 PROB 500.0

4.14. END
The END command is used to terminate a command data block.

The END command is a preliminary command, and should only appear at the head of the FATJACK
data set.

Parameters

END
Keyword

Usage

Compulsory to terminate all command data blocks.

4.15. FILES
The FILES command is used to define the prefix name for the backing files created in this run.

The FILES command is a preliminary command, and should only appear at the head of the FATJACK
data set.

Parameters

FILES
Keyword

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
82 of ANSYS, Inc. and its subsidiaries and affiliates.
FREQUENCY

fname
Prefix name for any backing files created by this run. (Alphanumeric, 4 characters, first character must
be alphabetic).

Usage

Optional, if omitted file name defaults to project name.

Notes

1. fname is used as a prefix for all files created during the current run. The four characters are appended
with two digits in the range 12 to 35 to create each individual file.

Examples
FILES BILL

4.16. FREQUENCY
The FREQUENCY command permits the definition of additional frequencies at which the stress transfer
function is to be evaluated in spectral analyses.

Parameters

FREQUENCY
Keyword

trans
Transfer function number to which these additional frequencies are to be added (Integer).

freq-list
List of frequency values. (Real, Hertz).

Notes

1. The frequencies defined MUST lie between the maximum and minimum frequencies associated with the
analyzed wave load cases forming the transfer function.

2. Stresses associated with the additional frequencies will be obtained by linear interpolation of stresses
obtained from adjacent (by frequency) factored analyzed wave loadcases which form the transfer function.

3. The frequency values must be given in Hertz, this cannot be changed by the use of UNITS command(s).

Examples
FREQ 10 0.142 0.150 0.175
: 0.210 0.225

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 83
FATJACK Command Reference

4.17. GAP
The GAP command allows specific gap information to be defined between pairs of braces forming K
and KT joints. For overlapping joints the through member is also defined.

Parameters

GAP
Keyword

joint
Joint number at which the gap is being defined (Integer).

brace
User element number specifying a brace forming part of a K or KT configuration about which the gap
is to be defined (Integer).

brace2
Second user element number corresponding to the second brace (Integer).

gap
User defined gap between braces brace and brace2. For overlapping gaps this dimension should be
negative (Real).

THRU
Keyword to indicate that through brace information is to follow for overlapping braces. Only permissible
if gap is negative.

braced
Brace element number representing the through member. Must be either brace or brace2 defined in
this command (Integer).

Notes

1. If GAP is not specified for a given K or KT joint, the gap adopts the value specified in the GAPDEFAULT
command. If the default gap dimension has not been defined the gap is computed based upon model
geometry. Where gap dimensions are computed these may be reset during the SCF computations to
prevent the use of gap values which would cause the SCF formulations becoming insoluble.

2. The Efthymiou SCF equations permit overlapping K and KT joints. This may be specified by defining a
negative gap value representing the length of the overlap. Under these circumstances, a through brace
must be defined since the equations differ for the through and overlapping member.

Examples
GAP 1100 1100 1110 50.0
GAP 1200 1200 1210 -35.0 THRU 1200

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
84 of ANSYS, Inc. and its subsidiaries and affiliates.
HIST

4.18. GAPDEFAULT
The GAPDEFAULT command is used to specify a default gap dimension to be used between pairs of
braces forming K and KT joints where specific gaps have not been defined.

Parameters

GAPDEFAULT
Keyword

equation
Equation type to which this default gap applies. Valid options are:

W
Wordsworth

K
Kuang

D
DS449

E
Efthymiou

gap
Default gap dimension (Real).

Notes

1. If GAPDEFAULT is not specified and a specific gap value is not defined for a given pair of braces forming
a K or KT joint, the gap dimension is computed based upon model geometry. Since joint geometry is
often simplified computed gaps may lead to erroneous values of generated stress concentration factors.

2. If gap dimensions are computed these may be reset during the SCF computations to prevent the use of
gap values which would cause the SCF formulations becoming insoluble.

Examples
GAPDEFAULT WORDSWORTH 50.0

4.19. HIST
The HIST command defines details of the analysis time histories to be included in a time history fatigue
analysis.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 85
FATJACK Command Reference

Parameters

HIST
Keyword

case
Wave history case number (Integer, > 0).

stru

For ASAS name of structure from which data is going to be obtained, structure must be in the same
project as that specified in preliminary data. If omitted, defaults to structure name given in the prelim-
inary STRUCTURE command (Alphanumeric, 4 characters), or

For ANSYS job identification name for the ANSYS job. If omitted, defaults to be first job referenced
(Alphanumeric, up to 8 characters).

start
First system loadcase (load step) to use from this analysis for rainflow counting. If omitted or 0, defaults
to 1 (Integer, >= 0).

end
Last loadcase (load step) to use from this analysis for rainflow counting. If omitted or 0, defaults to the
last loadcase analyzed. (Integer, >= 0).

interval
Interval between loadcases to use. If omitted or 0, defaults to 1. (Integer, >= 0).

Notes

1. If an optional value is specified, all preceding optional values must also be specified.

2. The ANSYS job identification name is formed by packing the structure name given in the preliminary
STRUCTURE command with the position of the job in the job name list file specified in the ANSYS
command. For example, ABCD18 means that the structure name is ABCD and the relevant job is the 18th
one in the list of jobs that appear in the job name list file.

Examples
HIST 1 aaaa 1 1001 1
HIST 2 bbbb
HIST 3

4.20. INSET
The INSET command defines the position along a brace at which the fatigue calculations are to be
computed. This is intended to account for moment back-off to the chord/brace interface.

Parameters

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
86 of ANSYS, Inc. and its subsidiaries and affiliates.
INSPECTION

INSET
Keyword

joint
Joint number at which the brace is connected (Integer).

brace
User element number to which the inset is to apply (Integer).

value
Inset value, positive values corresponding to moving along the brace away from the joint. The value
should not be greater than the element length (Real).

Notes

1. The value of the inset is added to any offsets modelled in the analysis for this brace.

2. The value of the bending moment used in the fatigue calculation is normally that occurring at the offset
end of the brace element connected to the joint. This value can sometimes be reduced by computing
an adjusted bending moment at the chord/brace interface; that is, at a distance of D/2 from the brace
element end, where D is the chord diameter.

3. The value of the bending moment will be computed by assuming that the member is subjected to a
uniformly distributed load, the magnitude of which is calculated from a difference in the end shears.

4. Use of this command to generate results well away from the nodal positions may provide misleading
fatigue lives due to the loading assumptions described in Note 3 above.

5. If design properties are given for the end of a brace at which an inset is defined, the properties will apply
to the inset location.

Examples
INSET 1000 1101 0.8

4.21. INSPECTION
This section discusses the following topics:
4.21.1. INSPECTION Command (Tubular sections)
4.21.2. INSPECTION Command (Non-tubular sections)

4.21.1. INSPECTION Command (Tubular sections)


This INSPECTION command defines the inspection points on tubular sections at which fatigue calculations
are to be undertaken. Inspection points can either be generated or defined explicitly.

Parameters

INSPECTION
Keyword

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 87
FATJACK Command Reference

ninsp
Number of inspection points to be generated (Integer).

ELEMENT
Keyword to indicate that a brace element list is to follow.

list
List of user brace element numbers to be assigned the inspection points (Integer).

ANGLE
Keyword to indicate that explicit inspection angles are to be defined.

joint
Joint number at which the brace being defined is connected (Integer).

brace
User element number to be assigned the inspection points (Integer).

theta
List of angles, measured in degrees from the saddle location (see below) (Real).

Notes

1. This command is optional. If omitted, or for elements not specified on INSPECTION commands, a default
of four inspection points will be generated corresponding to angles of 0, 90, 180 and 270 from the
primary saddle location (see Note 5 below).

2. If the ELEMENT keyword and associated list is omitted then the inspection points defined will apply to
all elements (unless overridden by explicit definitions for specific elements).

3. If inspection points are generated then they will be equi-spaced with the first point at 0 degrees (primary
saddle) and subsequent points with angles increasing by 360/ninsp. Thus if ninsp is 8 then the following
angles will be generated:

0 45 90 135 180 225 270 315

4. The ANGLE option allows any number of inspection points to be defined.

5. Generated and explicit angles are measured relative to a saddle location. The location of the saddle and
the relationship of other inspection points to this are shown below:

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
88 of ANSYS, Inc. and its subsidiaries and affiliates.
INSPECTION

For details of how the axis system is determined see Tubular Joint Inspection Points (p. 37).

Examples
INSP 8
INSPECTION 12 ELEMENT 5 TO 10
INSPECTION ANGLE 200 2010 0.0 51.0 96.0 132.0

4.21.2. INSPECTION Command (Non-tubular sections)


This INSPECTION command defines the inspection points on non-tubular sections at which fatigue cal-
culations are to be undertaken. Inspection points can either be generated or defined explicitly.

Parameters

INSPECTION
Keyword

SYMM
Keyword to indicate that 4 symmetric inspection points are to be defined.

POSN
Keyword to indicate that specific inspection points are to be defined.

y, z
Pair of ordinates defining a point on the beam section in local y and z directions (Real).

ELEMENT
Keyword to indicate that a brace element list is to follow.

list
List of user brace element numbers to be assigned the inspection points (Integer).

joint
Joint number at which the brace being defined is connected (Integer).

brace
User element number to be assigned the inspection points (Integer).

Notes

1. If sections have been utilized in the analysis the program will default to four inspection points as shown
in Section Profile Information (p. 125). The use of the INSPECTION command may be used to overwrite
this default.

2. The SYMM option generates 4 points as follows:

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 89
FATJACK Command Reference

3. The POSN option allows any number of inspection points to be defined.

4. No checks are carried out to ensure that the inspection point ordinates lie within the section (if defined).

Examples
INSPECTION SYMM 0.4 0.3
INSPECTION SYMM 425.0 250.0 ELEMENT 5 TO 10
INSPECTION POSN 200 2010 0.5 0.3 -0.5 0.3

4.22. JOB
The JOB command is used to define the type of analysis for the current run.

The JOB command is a preliminary command, and should only appear at the head of the FATJACK
data set.

Parameters

JOB
Keyword

POST
Keyword indicating post-processing of an analysis.

Usage

Compulsory.

Examples
JOB POST

4.23. JOINT
The JOINT command is used to select the joints at which the fatigue lives are to be computed. FATJACK
will generate a list of valid brace elements that are connected to the selected joints.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
90 of ANSYS, Inc. and its subsidiaries and affiliates.
LIMIT

Parameters

JOINT
Keyword

nodelist
User list of node numbers which equate to the required joints. Keywords ALL and TO may be utilized
if required (Integer).

Usage

Compulsory.

Notes

1. This command is compulsory and may be repeated as often as required to define the problem.

2. Braces connected to the joint which are not required in the fatigue calculation may be ignored using
the SECONDARY command.

3. Joints of K and KT configurations which have been modelled using two or three nodes require a reference
node to define the joint. Only the reference node should be defined on the JOINT command. For further
details see Joint Selection (p. 35).

Examples
JOINT ALL
JOINT 56 TO 66
JOINT 104 107 116 235

4.24. LIMIT
The SCF generators utilize parametric equations which have been derived for a limited range of values
for the parameters involved. The limiting values defined below are built into FATJACK, but these may
be overwritten, at the users discretion, using one or more LIMIT commands.

Parameters

LIMIT
Keyword

calc
Alphanumeric defining the equation type to which this limit applies. Permitted values are:

KUANG

WORDSWORTH

DS449

EFTHYMIOU

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 91
FATJACK Command Reference

limval
Keyword indicating parameter for which default applicability limit is to be overwritten (Alphanumeric).
Permitted values are:

ALPHA

BETA

GAMMA

TAU

THETA

minval
Lower applicability limit for parameter limval (Real).

maxval
Upper applicability limit for parameter limval (Real).

Notes

1. Default applicability limits are as follows (using the standard parameter definitions):

2. For any joint for which one or more parameters lie outside the limit values the SCF values will be calculated
with the actual values of the parameters and then recalculated with the appropriate parameters reset
to the limit values. The highest SCF value thus obtained will be taken.

If influence functions are being employed, coefficients at both the actual parameter and limiting
value are computed and stored. The critical hot spot stress is then computed as the maximum util-
izing either the actual or limiting parameter coefficients.

Examples
LIMIT KUAN ALPHA 10.0 35.0
LIMIT WORDSWORTH BETA 0.2 1.0

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
92 of ANSYS, Inc. and its subsidiaries and affiliates.
OPTIONS

4.25. NEWSTRUCTURE
The NEWSTRUCTURE command is used to define a new structure name to be associated with the results
created by the current run.

The NEWSTRUCTURE command is a preliminary command, and should only appear at the head
of the FATJACK data set.

Parameters

NEWSTRUCTURE
Keyword

nsname
Structure name to be associated with the results being created by the current run in order to identify
these results from others in the project. nsname must be unique for this project (Alphanumeric, 4
characters).

Usage

Optional.

Notes

1. If the NEWSTRUCTURE command is omitted then nsname defaults to the name ASNN. However, since
the structure name must be unique within a project, the default must not be assumed more than once
if the project contains a series of restarts.

2. A STRUCTURE command is normally required in conjunction with NEWSTRUCTURE to define the name
of the existing structure.

4.26. OPTIONS
The OPTIONS command is used to define the control options for this run.

The OPTIONS command is a preliminary command, and should only appear at the head of the
FATJACK data set.

Parameters

OPTIONS
Keyword

option
Four character option name, or list of option names. The following options are available:

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 93
FATJACK Command Reference

INFL - Requests that SCF calculations employing the Efthymiou empirical formulations are to use the
load influence methodology (See Joint Selection (p. 35)).

NOTR - Do not write results to the User Results Storage Database.

REFL - If wave spreading has been requested (using the SPREAD command), this option will select
wave cases in the opposite quadrant to couple with the requested direction (that is, reflecting the
wave by 1800).

SCFG - requests that a formatted SCF file is generated from any automatic SCF computations. No fatigue
life calculations will be undertaken. The SCFs will be written to filegs, where file is the 4 character file
name associated with this run (see FILES).

GOON - Proceed even after printed WARNINGS. This option allows the run to continue beyond the
data checks despite questionable data. It should only be used after a run in which the WARNINGS
have been noted and rejected as unimportant.

Usage

Optional.

Examples
OPTIONS INFL

4.27. PARAMETER
Program calculated values of most parameters for specific braces at a previously defined joint may be
overwritten using the PARAMETER command. This enables the user to calculate SCF values using
geometry.

Parameters

PARAMETER
Keyword

joint
Joint number to which the brace is connected (Integer).

param
Keyword indicating the parameter for which the calculated value is to be overwritten for SCF calculation.
Permitted values:

ALPHA

BETA

GAMMA

TAU

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
94 of ANSYS, Inc. and its subsidiaries and affiliates.
PRINT

THETA

pval
Value of parameter param to be used in SCF calculation (Real).

brace
Brace number for which parameter param is to be updated. This element must be connected to the
previously defined joint (Integer).

Examples
PARAMETER 1100 BETA 0.6 110010

4.28. PRINT
The PRINT command is used to select the type of results to be reported and the format of the report.
If omitted the default report is provided.

Parameters

PRINT
Keyword

report-item
Keyword identifying what information is to be reported. Valid names are:

XCHECK
Requests printing of cross checking information of input data.

SCFE
Requests a separate table of SCF information.

BRIEF
Brief fatigue report consisting of one line per joint/brace pair.

DETAILED
Standard fatigue report. Results are grouped by joint and provides lives at the worst inspection point
for a given brace.

FULL
Expands the BRIEF or DETAILED reports to include results for all inspection points.

SCFP
Adds SCF information to the BRIEF or DETAILED reports.

USAGE
Adds usage factor information to the BRIEF or DETAILED reports.

SUMMARY
Creates a summary report of braces which fail the fatigue target life.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 95
FATJACK Command Reference

DAMW
Requests damage per wave or sea-state. This is in addition to any other fatigue reports requested.

OCUR
Selects printing of stress ranges versus occurrences for spectral and time history analysis.

OCRT
As OCUR but produces results from for each transfer function for spectral analysis.

OCRW
As OCRT but produces results for each wave spectrum for spectral analysis.

PEAK
Requests that the stress peak value (+ve or -ve) is reported in a stress history analysis.

RNGE
Requests that the stress range is reported in a stress history analysis.

Notes

1. BRIEF and DETAILED options cannot be requested together.

2. FULL, SCFP and USAGE must be used in combination with BRIEF or DETAILED.

3. For spectral analyses with OCUR/OCRT/OCRW a SIGM command must be provided to define the sampling
points for the table. All other options (except XCHE and SCFE) are ignored.

4. PEAK/RNGE are only valid for stress history analyses and are mutually exclusive.

5. DAMW and OCRT/OCRW may produce large amounts of information and should be used only for selective
fatigue runs.

6. PRINT commands are cumulative so required reports may be requested individually or on one or more
lines.

Examples
PRINT BRIEF FULL SCFP SUMMARY
PRINT XCHECK DETAILED DAMW

4.29. PROJECT
The PROJECT command is used to define the project name for the current run.

The PROJECT command is a preliminary command, and should only appear at the head of the
FATJACK data set.

Parameters

PROJECT
Keyword

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
96 of ANSYS, Inc. and its subsidiaries and affiliates.
RESU

pname
Project name for current run (Alphanumeric, 4 characters, first character must be alphabetic).

Usage

Optional, if omitted project name defaults to ASAS.

Notes

1. All runs with the same project name access the same database. A project database consists of one project
file (with a file name consisting of the 4 characters of pname with the number 10 appended), which acts
as an index to other files created under this project, together with those other files.

Examples
PROJECT HIJK

4.30. REDUCTION
The REDUCTION command requests the use of the Marshall Reduction factor for brace side SCF values
computed using the Kuang equations.

Parameters

REDUCTION
Keyword

factor
Optional factor to be applied (Real).

Usage

Optional, and may be defined only once.

Notes

1. If this command is omitted completely no brace side reduction will take place.

2. If the factor is omitted, a default value of 0.63 will be utilized (as suggested by API).

3. The resulting brace side SCF values will be given by:

SCFbrace = factor * SCFchord

Examples
REDUCTION
REDU 0.7

4.31. RESU
The RESU command is used to specify saving of results to the results database.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 97
FATJACK Command Reference

The RESU command is a preliminary command, and should only appear at the head of the FATJACK
data set.

Parameters

RESU: Keyword.

Notes

1. For the results database to be used in any post-processing run with the ASAS solvers a RESU command
must be included in the initial ASAS run to initialize the database.

Examples
RESU

4.32. SCF Definition


Stress concentration factors (SCFs) relate hot spot stresses to the nominal stresses in a member computed
from the axial forces and in-plane and out-of-plane bending moments. FATJACK provides facilities for
both defining explicit SCF values and for automatically generating the SCF values using one or more
established empirical formulations.

Explicit and generated SCF values may be mixed as necessary to achieve the desired result.

A summary of available commands is shown below with detailed descriptions given in the following
sections.

Note that if influence functions are used to compute the hot spot stresses for braces at a given joint,
it is not currently possible to override the computed influence terms with conventional SCFs. Any user
specified values will be ignored.

Table 4.4: Commands available for explicit SCF specification

Command Description
SCF TUB DEFAULT Specifies default SCF values for a given section type

SCF WF DEFAULT

SCF RHS DEFAULT

SCF BOX DEFAULT


SCFJOINT Specifies crown and saddle SCF values at specified joints for tubular braces
SCFANGLE Specifies SCF values at specific angular inspection points for tubular braces
SCFBRACE Specifies SCF values at all inspection points for non-tubular braces

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
98 of ANSYS, Inc. and its subsidiaries and affiliates.
SCF Definition

Command Description
SCFPOINT Specifies SCF values at specific inspection points for non-tubular braces

Table 4.5: Commands available for automatic SCF specification

Command Description
SCF AUTO DE- Specifies default empirical equation(s) to be utilized for the SCF generation
FAULT
SCF AUTO JOINT Specifies joints at which automatic computation of SCF values to be undertaken
SCFMINIMUM Specifies minimum values for the SCF components calculated in automatic
generation
LIMIT Permits user defined applicability limits for the parameters utilized in automatic
SCF generation
PARAMETER Permits explicit definition of the parameters utilized in automatic SCF generation
for specific braces

4.32.1. SCFANGLE Command


The SCFANGLE command defines stress concentration factors to be applied at specific inspection points
around a tubular brace. This is useful where a detailed joint analysis has been undertaken and explicit
SCF values are known.

Parameters

SCFANGLE
Keyword

joint
Joint number to which the brace is connected (Integer).

brace
Brace user element number for which the SCF values are to be specified (Integer).

angle
Angle (in degrees) from inspection point 1 (Real).

bscfa
Brace side SCF for axial force (Real).

bscfip
Brace side SCF for in-plane bending (Real).

bscfop
Brace side SCF for out-of-plane bending (Real).

cscfa
Chord side SCF for axial force (Real).

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 99
FATJACK Command Reference

cscfip
Chord side SCF for in-plane bending (Real).

cscfop
Chord side SCF for out-of-plane bending (Real).

Notes

1. If only bscfa is specified, this value will be adopted for all six SCF values.

2. If SCFANGLE is used for a brace, results will only be computed at those inspection points explicitly
defined by the angles provided in the SCFANGLE commands. Any INSPECTION commands referring to
this brace end will be ignored. This implies that the SCF values at ALL inspection points need to be
provided. Where crown and saddle SCF values are known, use should be made of the SCFJOINT command.

3. For any given brace, SCFANGLE and SCFJOINT are mutually exclusive and cannot be used together in
the same run of FATJACK.

Examples
SCFA 1100 110010 45.0 3.5 5.0 5.0 3.5 5.0 5.0
SCFANGLE 85 1185 90.0 4.5

4.32.2. SCF AUTO DEFAULT Command


The SCF AUTO DEFAULT command defines the default generic empirical formulations to be used when
calculating the SCFs to be applied. The equations may be specified for given locations and stress com-
ponents thus permitting the use of the most appropriate formulation. Joints at which automatic SCF
computations are to be undertaken should be specified using the SCF AUTO JOINT command.

Parameters

SCF
Keyword

AUTO
Keyword

DEFAULT
Keyword

GENERAL
Keyword to denote that the equation matrix is applied to all joint types (unless overwritten).

type
Joint type to which this default matrix is to be applied (Alphanumeric). Valid joint types are:

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
100 of ANSYS, Inc. and its subsidiaries and affiliates.
SCF Definition

KT

matrix
Defines the empirical formulations to be adopted for the following stress components and locations:

Brace side axial crown

Brace side axial saddle

Brace side in-plane bending

Brace side out-of-plane bending

Chord side axial crown

Chord side axial saddle

Chord side in-plane bending

Chord out-of-plane bending

The matrix consists of a series of characters representing the equation type to be used for each of
the stress components and locations above. Valid options are:

W
Wordsworth

K
Kuang

D
DS449

E
Efthymiou

Notes

1. Specific joint type definitions override those given by GENERAL commands.

2. If only one value is provided then this will be used for all stress components and locations. Either one
or eight equation identifiers must be defined.

3. If influence functions are employed then only Efthymiou equations may be requested. Other equation
types will produce an error.

Examples
SCF AUTO DEFA GENE K K W W K K W W
SCF AUTO DEFAULT KT E

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 101
FATJACK Command Reference

4.32.3. SCF AUTO JOINT Command


The SCF AUTO JOINT command is used to request the joints at which automatic computation of SCF
values is to be undertaken. The equations to be used may be specified if they differ from those given
in the default definitions.

Parameters

SCF
Keyword

AUTO
Keyword

JOINT
Keyword

matrix
Defines the empirical formulations to be adopted for the following stress components and locations for
the braces connected to the specified jointlist:

Brace side axial crown

Brace side axial saddle

Brace side in-plane bending

Brace side out-of-plane bending

Chord side axial crown

Chord side axial saddle

Chord side in-plane bending

Chord out-of-plane bending

The matrix consists of a series of characters representing the equation type to be used for each of
the stress components and locations above. Valid options are:

W
Wordsworth

K
Kuang

D
DS449

E
Efthymiou

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
102 of ANSYS, Inc. and its subsidiaries and affiliates.
SCF Definition

jointlist
List of joints at which automatic SCF generation is to be undertaken. Keywords ALL and TO may be
generate lists of joints (Integer).

Notes

1. If the matrix is omitted the default matrices for the brace configurations occurring at the specified joint
will be adopted.

2. If the matrix is specified it will be used for all braces connected to the specified joints irrespective of the
brace configurations.

3. If only one value is provided for the matrix then this will be used for all stress components and locations.
If any locations are different then all eight equation identifiers must be defined.

4. If influence functions are employed then only Efthymiou equations may be requested. Other equation
types will produce an error.

Examples
SCF AUTO JOINT ALL
SCFANGLE 85 1185 90.0 4.5
SCF AUTO JOIN E 10 TO 25
SCF AUTO JOIN K K W W K K W W 100 200 300

4.32.4. SCFBRACE Command


The SCFBRACE command defines stress concentration factors to be applied at all inspection points for
non-tubular braces.

Parameters

SCFBRACE
Keyword

joint
Joint number to which the brace is connected (Integer).

brace
Brace user element number for which the SCF values are to be specified (Integer).

bscfa
Brace side SCF for axial force (Real).

bscfip
Brace side SCF for in-plane bending (Real).

bscfop
Brace side SCF for out-of-plane bending (Real).

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 103
FATJACK Command Reference

cscfa
Chord side SCF for axial force (Real).

cscfip
Chord side SCF for in-plane bending (Real).

cscfop
Chord side SCF for out-of-plane bending (Real).

Notes

1. If only bscfa is specified, this value will be adopted for all six SCF values.

2. SCF values defined will be applied at each of the inspection points defined using the INSPECTION
command. If different values are required at each inspection point the SCFPOINT command should be
used.

Examples
SCFB 100 1010 3.5
SCFB 200 20200 4.0 4.5 4.5 4.0 4.5 4.5

4.32.5. SCF DEFAULT Command


The SCF DEFAULT command defines the default stress concentration factors to be applied to elements
of a given section type.

Parameters

SCF
Keyword

TUB, WF, RHS, BOX


Alphanumeric keyword defining type of section to which the default is to be applied.

DEFAULT
Keyword

bscfa
Default brace side SCF for axial force (Real).

bscfip
Default brace side SCF for in-plane bending (Real).

bscfop
Default brace side SCF for out-of-plane bending (Real).

cscfa
Default chord side SCF for axial force (Real).

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
104 of ANSYS, Inc. and its subsidiaries and affiliates.
SCF Definition

cscfip
Default chord side SCF for in-plane bending (Real).

cscfop
Default chord side SCF for out-of-plane bending (Real).

Notes

1. This command is compulsory and must be defined only once for each section type that is to be processed.
The SCF value(s) specified will be adopted for any braces at joints which have not had specific SCF values
defined, or where automatic SCF calculation has not been requested.

2. If only bscfa is specified then this value will be adopted for all six SCF values.

Examples
SCF TUB DEFAULT 3.5
SCF TUB DEFA 3.0 3.5 3.5 3.0 3.5 3.5

4.32.6. SCFJOINT Command


The SCFJOINT command is used to specify user defined crown and saddle SCF values for tubular braces
at specified joints. Selected locations may optionally adopt values computed from empirical SCF formu-
lations.

Parameters

SCFJOINT
Keyword

joint
Joint number to which the brace is connected (Integer).

brace
Brace user element number for which the SCF values are to be specified (Integer).

CHORD
Keyword to denote chord side SCF values are to be defined.

BRACE
Keyword to denote brace side SCF values are to be defined.

AUTO
Keyword to request that a computed value using the empirical formulations selected on an SCF AUTO
DEFAULT or SCF AUTO JOINT command is to be adopted.

axc
SCF for axial load, crown position (Real).

axs
SCF for axial load, saddle position (Real).

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 105
FATJACK Command Reference

ipc
SCF for in-plane bending, crown position (Real).

ips
SCF for in-plane bending, saddle position (Real).

opc
SCF for out-of-plane bending, crown position (Real).

ops
SCF for out-of-plane bending, saddle position (Real).

Notes

1. If the AUTO keyword is used for any locations then a complementary SCF AUTO DEFAULT or SCF AUTO
JOINT command should be provided to define the method which is to be utilized for generating the
undefined values. This is also true if the chord or brace side definitions are completely omitted.

2. The ips and opc terms are strictly not required since the associated bending stress terms at these locations
are zero. They are used, however, if inspection points are selected at positions between the saddle and
crown locations. It is recommended, therefore, that the values are set the same for the crown and saddle
locations; that is ips set to ipc and opc set to ops. See SCF Interpolation (p. 41) for details about the
interpolation of SCF values at intermediate locations.

3. For the SCF values to be correctly applied a chord must be identified for the joint concerned. This can
either be computed by the program, or may be specified using the CHORD command.

Examples
SCFJ 100 1010 CHORD 3.5 3.0 4.0 4.0 3.8 3.8
SCFJ 100 1010 BRACE AUTO AUTO 4.2 4.2 4.15 4.15

4.32.7. SCFMINIMUM Command


The SCFMINIMUM command may be used to specify minimum values for the SCF components calculated
in the automatic SCF generation.

Parameters

SCFMINIMUM
Keyword

scfnam
Optional alphanumeric name indicating the SCF component for which the minimum SCF value is to be
specified. Permitted names are:

BAXS
Brace side axial saddle

BAXC
Brace side axial crown

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
106 of ANSYS, Inc. and its subsidiaries and affiliates.
SCF Definition

BIPC
Brace side in-plane bending crown

BOPS
Brace side out-of-plane bending saddle

CAXS
Chord side axial saddle

CAXC
Chord side axial crown

CIPC
Chord side in-plane bending crown

COPS
Chord side out-of-plane bending saddle

scfmin
Minimum SCF (Real).

Notes

1. If scfmin is omitted then the SCF value defined will be adopted as a minimum for all SCF components
defined above.

2. The value(s) defined will only be applied to the SCF computations if they are appropriate to the method-
ology adopted.

Examples
SCFM COPS 2.5
SCFM 2.0

4.32.8. SCFPOINT Command


The SCFPOINT command defines stress concentration factors to be applied at specific inspection points
on non-tubular sections.

Parameters

SCFPOINT
Keyword

joint
Joint number to which the brace is connected (Integer).

brace
Brace user element number for which the SCF values are to be specified (Integer).

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 107
FATJACK Command Reference

y, z
Pair of ordinates defining a point on the beam section in local y and z directions (Real).

bscfa
Brace side SCF for axial force (Real).

bscfip
Brace side SCF for in-plane bending (Real).

bscfop
Brace side SCF for out-of-plane bending (Real).

cscfa
Chord side SCF for axial force (Real).

cscfip
Chord side SCF for in-plane bending (Real).

cscfop
Chord side SCF for out-of-plane bending (Real).

Notes

1. If only bscfa is specified, this value will be adopted for all six SCF values.

2. If SCFPOINT is used for a brace, results will only be computed at those inspection points explicitly defined
by the ordinates provided in the SCFPOINT commands. Any INSPECTION commands referring to this
brace end will be ignored. This implies that the SCF values at ALL inspection points need to be provided.
Where SCF values are constant around the section, use should be made of the SCFBRACE command.

3. For any given brace, SCFPOINT and SCFBRACE are mutually exclusive and cannot be used together in
the same run of FATJACK.

Examples
SCFP 1100 110010 0.0 0.85 3.5 5.0 5.0 3.5 5.0 5.0
SCFPOINT 85 1185 0.65 0.50 4.5

4.33. SECONDARY
The SECONDARY command is used to specify that certain elements are to be classified as secondary
members and omitted from the fatigue computations.

Parameters

SECONDARY
Keyword

ELEMENT
Keyword to denote selection by element number.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
108 of ANSYS, Inc. and its subsidiaries and affiliates.
SIGM

GROUP
Keyword to denote selection by element group number.

PROPERTY
Keyword to denote selection by geometric property number.

list
List of user element, group or geometric property numbers to which this data is to be assigned (Integer).
The list may include the keyword TO but not ALL.

Notes

1. Elements defined as secondary will not have fatigue calculations undertaken. Their effect will also be
ignored in joint classification for the purposes of SCF calculations and will not be included in influence
coefficient calculations.

Examples
SECO ELEM 100 TO 110
SECO GROUP 999

4.34. SIGM
The SIGM command is required when stress range versus occurrence information has been requested
(using PRINT OCUR/OCRT/OCRW commands) and provides the additional information necessary to
generate the required table.

Parameters

SIGM
Keyword

peak
Peak stress range required (Real).

nint
Number of intervals to sample stress range (Integer).

Notes

1. This command is compulsory if PRINT OCUR/OCRT/OCRW has been requested.

2. Use of the PRINT OCUR/OCRT/OCRW commands requires that intervals of stress range are defined over
which the spectral information may be integrated to produce occurrence data for that range. The interval
of stress range is computed by dividing the peak value by the number of sampling intervals. The mid
value for each interval is then used as a reference value for that interval.

Examples

A data line of:


SIGM 1.0E6 5

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 109
FATJACK Command Reference

will produce sampling points of:


1.0E5 3.0E5 5.0E5 7.0E5 9.0E5

Or graphically:

4.35. S-N
The S-N command assigns S-N curves (user or predefined) to brace elements to be analyzed.

Parameters

S-N
Keyword

name
Name of S-N curve to be assigned (Alphanumeric). This may either reference a standard S-N design curve
or a user defined curve (using the CURVE command).

END1, END2
Optional keywords to denote that the S-N curve is to be assigned to only one end of the element(s).

ELEMENT
Keyword to denote selection by element number.

GROUP
Keyword to denote selection by element group number.

list
List of elements or groups to which the S-N data is to be associated. (Integer.) Keywords ALL and TO
may be used to generate the list.

Notes

1. The following built in design curves are currently available:

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
110 of ANSYS, Inc. and its subsidiaries and affiliates.
SPECTRUM

DET, DEF2 Department of Energy T and F2 (in Air) curves


APX, APXD API RP2A X and X curves
DOT Danish Offshore Regulations DS412 tubular curve

2. If END1/END2 is omitted the curve is assigned to both ends of the brace element(s).

Examples
S-N APX ELEM 1000 TO 5000

4.36. SPECTRUM
The SPECTRUM command defines the wave spectrum probability information. The wave spectra are
assigned to a transfer function number which relates analyzed waves to a spectra by way of the
TRANSFER command. The sea state spectra may be supplied using predefined spectra or as user defined
ordinates on the wave energy spectrum diagram.

Parameters

SPECTRUM
Keyword.

itrans
Transfer function number (Integer).

SCTW
Keyword indicating Scott-Wiegel spectrum.

JONS
Keyword indicating JONSWAP spectrum (See Ref. 6).

PMOS
Keyword indicating Pierson-Moskowitz spectrum (See Ref. 5).

OCHI
Keyword indicating Ochi-Hubble spectrum (See Ref. 7).

UDEF
Keyword indicating user defined spectrum.

height
Significant wave height (Real).

period
Zero crossing period (Real).

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 111
FATJACK Command Reference

prob
Probability (Real).

c1, c2
Constants used in defining Scott-Wiegel spectrum (Real).

hs1
Swell component significant wave height for Ochi-Hubble spectrum.

tp1
Swell component wave peak period for Ochi-Hubble spectrum.

peak1
Peakedness for swell component for Ochi-Hubble spectrum.

hs2
Wave component significant wave height for Ochi-Hubble spectrum.

tp2
Wave component wave peak period for Ochi-Hubble spectrum.

peak2
Peakedness for wave component for Ochi-Hubble spectrum.

strord
Stress direct spectral ordinate (input in the same order as the waves in the transfer function) (Real).

Notes

1. The units in which the probability is input (for example, occurrences per year, percentages, etc.) is imma-
terial providing it is consistent for all the spectral data defined. The program computes a true probability
for each sea-state by dividing each input probability by the sum of all the probabilities.

2. Only one of SCTW, JONS, PMOS, OCHI or UDEF may be used in any one transfer function.

3. The Ochi-Hubble wave spectrum is bimodall; that is, it includes a swell and wave component.

4. For user defined spectra the frequency abscissae are extracted from the wave data defined for the
transfer function. The order of the stress ordinate data should be in increasing frequency of the wave
data assigned to this transfer function, including any additional frequencies defined.

Examples

Example of JONSWAP spectrum using three base wave cases:


TRANS 100 4 1.0 5 1.0 6 1.0
SPEC 100 JONS 2.0 4.0 1.0
SPEC 100 JONS 5.0 5.0 10.0
SPEC 100 JONS 20.0 9.0 50.0

Example of user-defined spectrum using three base wave cases:


TRANS 10 10 1.1 11 1.12 12 1.09
SPEC 10 UDEF 1.0 1.93 1.786 0.926
SPEC 10 UDEF 10.0 12.79 7.23 2.86
SPEC 10 UDEF 50.0 35.42 14.71 4.91

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
112 of ANSYS, Inc. and its subsidiaries and affiliates.
SPREADING

Example of Ochi-Hubble spectrum:


TRANS 5 10 1.0 11 1.0
SPEC 5 OCHI 1.8 14.5 6.0 0.0 0.0 0.75 1.8
SPEC 5 OCHI 0.9 12.5 6.0 0.3 5.5 0.75 2.1
SPEC 5 OCHI 0.9 12.5 6.0 0.3 5.5 0.75 2.1

4.37. SPREADING
The SPREADING command requests that wave spreading should be applied.

Parameters

SPREADING
Keyword

power
Power of wave spreading function. If omitted, see notes for default values.

MITS
Requests Mitsuyasu spreading method. See Note 3(a).

MMIT
Requests modified Mitsuyasu spreading method. See Note 3(b).

GODA
Requests Goda spreading method. See Note 3(c).

Notes

1. The command is only valid for spectral analysis. If the command is omitted, no wave spreading calculations
will be carried out.

2. Wave spreading is NOT permissible with the Ochi-Hubble wave spectrum.

3. Wave spreading calculations may be undertaken by any one of the three methods described below. If
SPREADING is supplied but no method is selected, MITS is used by default. Note that in all cases the
calculations are carried out on the stress transfer function squared.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 113
FATJACK Command Reference

(a) Mitsuyasu spreading method (See Ref. 8).

If MITS is requested then the Mitsuyasu wave spreading function is utilized, defined by:



 = 
=
  

where:


nw is the number of waves in the range

n is the defined wave spreading power (default value is 4.0)
Tn is the transfer function prior to wave spreading
Ts is the transfer function modified for wave spreading
is the angle of the wave d relative to the mean wave direction
is the angle over which the wave d is applied (radians)
Cn is the normalization function

 =  

 =
(b) Modified Mitsuyasu spreading method (See Ref. 8).

If MMIT is requested then wave spreading calculations will be carried out using the modified Mitsuyasu
formula (based upon the complete wave environment) which is defined by:


 =   

 =
where:

nw is the number of waves in the range   


n is the defined wave spreading power (default value is 4.0)
Tn is the transfer function prior to wave spreading
Ts is the transfer function modified for wave spreading
is the angle of the wave d relative to the mean wave direction
is the angle over which the wave d is applied (radians)
Cn is the normalization function

 = #


! = "
(c) Goda spreading method (See Ref. 9).

If GODA is requested then wave spreading calculations will be carried out using the Goda formula
which is defined by:

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
114 of ANSYS, Inc. and its subsidiaries and affiliates.
SPREADING

 
 = 
=
  

where:

nw is the number of waves in the range


Tn is the transfer function prior to wave spreading
Ts is the transfer function modified for wave spreading
is the angle of the wave d relative to the mean wave direction
is the angle over which the wave d is applied (radians)
Cn is the normalization function

 =  
 

 = 
r is the equation



 
 
=


 > 

 

where:

rmax is the defined peak spreading power (default 10.0)


f is the frequency
fp if the frequency associated with the spectral peak

For all three methods is computed by the program by computing the angle between adjacent ana-
lysis waves. For example, for an analysis with wave directions in 45 increments, will be 0.79 radians
and, for the default spreading, nw will be 5(-/2 <= <= /2). For Goda and Mitsuyasu nw will be 8(-
<= <= ).

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 115
FATJACK Command Reference

4.38. STOP
The STOP command is needed to signify the end of the data.

Parameters

STOP: Keyword.

4.39. STRUCTURE
The STRUCTURE command is used to define the name of an existing structure within the current project
which is to be processed in this run.

The STRUCTURE command is a preliminary command, and should only appear at the head of the
FATJACK data set.

Parameters

STRUCTURE
Keyword

sname
Structure name identifying which existing structure is to be accessed from the current project, see
PROJECT command (Alphanumeric, 4 characters, the first character must be alphabetic).

Usage

Compulsory.

Notes

1. See COMPONENT command.

Examples
STRUCTURE JACK

4.40. SYSTEM
The SYSTEM command is used to define the amount of memory used for data by this run.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
116 of ANSYS, Inc. and its subsidiaries and affiliates.
TEXT

The SYST command is a preliminary command, and should only appear at the head of the FATJACK
data set.

Parameters

SYSTEM
Keyword

DATA AREA
Keywords

memory
Amount of memory (in 4 byte words) to be used by this run. Typical values are between 30000 and
1000000. If the SYSTEM command is omitted, a default value of 1000000 is used. (Integer)

Usage

Optional.

Examples
SYSTEM DATA AREA 80000

4.41. TEXT
The TEXT command is used to define a line of text to be printed once only at the beginning of the
output. Several TEXT lines may be defined to give a fuller description of the current analysis on the
printed output.

The TEXT command is a preliminary command, and should only appear at the head of the FATJACK
data set.

Parameters

TEXT
Keyword

text
This line of text will be printed once, at the beginning of the output (Alphanumeric, up to 75 characters).

Usage Optional.

Examples
TEXT THIS EXAMPLE OF THE
TEXT TEXT COMMAND IS SPREAD
TEXT OVER THREE LINES

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 117
FATJACK Command Reference

4.42. THICKNESS
The THICKNESS command is used to request modification of the S-N curves to account for varying
plate thickness. S-N curves are generally specified for material thicknesses up to a given base value,
above this value the fatigue strength decreases with increasing thickness for a given level of stress
range. For built in S-N curves the base thickness is normally predefined (see below). For user defined
curves the base value must be supplied on the CURVE command.

Parameters

THICKNESS
Keyword

power
Power to be used in the thickness correction. If not defined the value defaults to 0.3 (in accordance with
the current Health and Safety Executive Guidance Notes).

Notes

1. This command may be defined only once. If omitted then no thickness correction will be undertaken.

2. The following base thicknesses are used for the built in S-N curves:

Curve tb
DET 32 mm
DEF2 22 mm
APX 25 mm
APXD 16 mm
DOT N/A

If the DOT S-N curve is being used, a base thickness must be supplied as part of the S-N data.

3. The correction has the effect of multiplying the stress range at an inspection point by the factor:

For all curve types except DET, t is set to be at least tb; that is, no reduction can occur. For the T
curve, t is set to be at least 22 mm; that is, a beneficial reduction is achieved for thicknesses between
22 and 32 mm.

Examples
THICK
THICK 0.25

4.43. TITLE
The TITLE command is used to define a title for this run.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
118 of ANSYS, Inc. and its subsidiaries and affiliates.
TRANSFER

The TITLE command is a preliminary command, and should only appear at the head of the FATJACK
data set.

Parameters

TITLE
Keyword

title
This line of text will be printed out at the top of each page of FATJACK output (Alphanumeric, up to 74
characters).

Usage

Recommended.

Examples
TITLE THIS IS AN EXAMPLE OF A TITLE LINE

4.44. TRANSFER
The TRANSFER command defines the constituent base wave cases for a given transfer function.

Parameters

TRANSFER
Keyword

itrans
Transfer function number (Integer).

case
Base wave case number for this transfer function. (Integer).

factor
Multiplying factor (dynamic amplification factor) to be applied to this base case (Real).

Notes

1. If additional frequencies are defined (using the FREQUENCY command) then these are automatically
included in the associated transfer function.

2. The command may be repeated as many times as is required to fully define the transfer function.

Examples

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 119
FATJACK Command Reference

TRAN 5 10 1.09 11 1.12

4.45. TYPE
The TYPE command is used to predefine specific joint configurations for a given brace member (or
members) at a joint. This command is compulsory if joints are modelled with two or three nodes. The
configurations are used for the automatic computation of stress concentration factors.

Parameters

TYPE
Keyword

joint
Joint number at which the joint type is being defined (Integer).

type
Joint type (Alphanumeric). Valid joint types are:

KT

brace
User element number specifying a brace which is to be assigned this configuration. For KT joints this
must also be the central brace member (Integer).

brace2
Second user element number corresponding to the second brace in a K, X or KT joint (Integer).

brace3
Third user element number corresponding to the third brace of a KT joint (Integer).

Notes

1. For simple joints, modelled with a single node, this command is optional and if omitted the joint config-
uration is automatically computed as T, Y, K, X or KT depending upon the chord brace geometry. See
Joint Classification (p. 36) for details.

2. If influence functions are used any additional braces connected to the joint will be included unless declared
as secondary.

Examples
TYPE 100 T 1000
TYPE 250 KT 1100 1110 1120

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
120 of ANSYS, Inc. and its subsidiaries and affiliates.
UNITS

4.46. UNITS
The UNITS command is used to define the UNITS which have been used in the previous analysis.

Parameters

UNITS
Keyword

unitnm
Name of unit to be utilized (see Notes).

Usage

The default units adopted for the input data will be those utilized in the original analysis and if this is
satisfactory no additional information is required in the FATJACK run.

If it is required to input any of the FATJACK data in a different system of units, this can achieved by
specifying one or more UNITS commands within the main body of the FATJACK data thus permitting
a combination of unit systems within the one data file.

Notes

1. By default, the analysis units used in the previous analysis will be used.

2. If analysis units were not defined for the previous analysis, the units used MUST be specified here. If
analysis units were defined for the previous analysis, they can be reconfirmed here but cannot be changed.

3. The UNITS command may be repeated throughout the data block thus permitting the greatest flexibility
in data input.

4. Force, length and angular unit may be specified. Only those terms which are required to be modified
need to be specified, undefined terms will default to those of the analysis global units unless previously
overwritten by another UNITS command. The default angular unit is degrees for all data types.

5. Analysis units must be defined if it is intended to use the UNITS command in the main FATJACK data.
Valid unit names are as follows:

Length METRE(S) M
CENTIMETRE(S) CM
MILLIMETRE(S) MM
MICROMETRE(S) MICM
NANOMETRE(S) NANM
FOOT, FEET FT
INCH, INCHES IN

Force NEWTON(S) N

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 121
FATJACK Command Reference

KILONEWTON(S) KN
MEGANEWTON(S) MN
TONNEFORCE(S) TNEF
POUNDAL(S) PDL
POUNDFORCE LBF
KIP(S) KIP
TONFORCE(S) TONF
KGFORCE(S) KGF

Examples

To define or reconfirm the analysis units:


UNIT N M

To switch the length unit of the input data to millimetre:


UNIT MM

4.47. WAVE
The WAVE command defines the association between the analyzed load cases and the wave information
used to generate the loads. If the wave loading was generated by WAVE, the association may be extracted
automatically.

Parameters

WAVE
Keyword.

AUTO
Keyword to denote that wave information is to be extracted from the analysis files.

case
Wave case number associated with this wave data (Integer).

height
Wave height (Real).

period
Wave Period (Real).

direction
Wave direction (Real).

NPOS
Keyword to denote that the number of wave positions associated with this wave case is to be defined.
This is required for stress history analysis only.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
122 of ANSYS, Inc. and its subsidiaries and affiliates.
YEAR

npos
Number of wave positions associated with this wave case (Integer).

Notes

1. For wave loading generated or modified outside WAVE then the WAVE data must be supplied explicitly:

a. The WAVE commands must be specified in the order corresponding to the order of the analyzed
wave load cases.

b. The wave case numbers are independent of the load case numbers used in the analysis.

c. All wave cases analyzed must be defined.

2. For WAVE AUTO:

a. This command may only be used if the wave loading was generated using the WAVE program, and
no additional loading information was added prior to the analysis.

b. Loadcases will be generated sequentially from 1. For deterministic and spectral analyses there will
be one wave case for each analyzed load case pair. For stress history analysis due account will be
taken of the number of wave steps used in analyzing each wave case.

Examples
WAVE 10 12.0 10.0 180.0
WAVE 6 13.5 9.8 90.0 NPOS 8
WAVE AUTO

4.48. YEAR
The YEAR command defines the target fatigue life of the structure. Braces with fatigue lives less than
this value will be flagged as having failed.

Parameters

YEAR
Keyword

target
Target life in years (Real).

Examples
YEAR 50.0

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 123
Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
124 of ANSYS, Inc. and its subsidiaries and affiliates.
Chapter 5: FATJACK Appendices
This section discusses the following topics:
5.1. Running FATJACK
5.2. Section Profile Information
5.3. FATJACK References

5.1. Running FATJACK


This section discusses the following topics:
5.1.1. ASAS Files Required by FATJACK
5.1.2. Files saved by FATJACK

5.1.1. ASAS Files Required by FATJACK


FATJACK operates on the RST files produced by a preceding Mechanical APDL analysis.

5.1.2. Files saved by FATJACK


If the RESU command is specified in the FATJACK data, then the results can be extracted (for example,
via AXL) or viewed graphically.

5.2. Section Profile Information


The following are the dimensional information required for each of the section types that may be specified
using a DESIGN command. For each section defined below, the four locations at which fatigue calculations
are undertaken are marked.

5.2.1. BOX - Symmetric Fabricated Box Section

Dimensional Properties: dbtf tw

where:

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 125
FATJACK Appendices

d
is the beam depth

b
is the beam width

tf
is the thickness of the top and bottom plates

tw
is the thickness of the side plates

5.2.2. RHS - Rolled Hollow Section

Dimensional Properties: dbt

where:

d
is the beam depth

b
is the beam width

t
is the thickness

5.2.3. TUB - Tubes of Circular Section

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
126 of ANSYS, Inc. and its subsidiaries and affiliates.
FATJACK References

Dimensional Properties: Dt

where:

D
is the outer diameter

t
is the wall thickness

5.2.4. WF - Wide Flanged Rolled I-Section

Dimensional Properties: dbtftw

where:

d
is the beam depth

b
is the flange width

tf
is the flange thickness

tw
is the web thickness

5.3. FATJACK References


Ref. Barltrop, N.D.P. & Adams, A.J., 1991, Dynamics of Fixed Marine Structures,
1 Third Edition.
Ref. Wordsworth, A.C. & Smedley, G.P., 1978, Stress concentrations at unstiffened
2 tubular joints, European offshore steels research seminar.
Ref. Kuang, J.G., Potvin, A.B., Leick, R.D., and Kahlich, J.L., 1977, Stress concentration
3 in tubular joints, Society of Petroleum Engineers Journal.
Ref. Department of Energy, 1990, Offshore Installations: guidance on design,
4 construction and certification, 4th edition, HMSO.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 127
FATJACK Appendices

Ref. Pierson, W.J., and Moskowitz, L., 1964, A proposed spectral form of fully de-
5 veloped wind seas based on the similarity theory of S.A. Kitaigorodskii,
Journal of Geophysical Research, Volume69.
Ref. Hasselmann, D.W., Dunckel, M. and Ewing, J.A., 1989, Directional Wave Spectra
6 observed during JONSWAP in 1973, Journal Physical Oceanography 10.
Ref. Ochi, M.K., 1976, Proceedings of the 15th Coastal Engineering Conference,
7 ASCE.
Ref. Mitsuyasu, H. et al, 1975 Observations of the directional spectrum of ocean
8 waves using a cloverleaf buoy, Journal Physical Oceanography, Vol. 5.
Ref. Goda, Y. and Suzuki, Y., 1975, Computation of refraction and diffraction of
9 sea waves with Mitsuyasus directional spectrum, Tech. Note of Port and
Harbour Research Institute No 230.
Ref. DS449 Dansk Ingenirforening 1984, Pile-Supported Offshore Steel Structures,
10 Part 2, AnnexE.
Ref. Efthymiou, M. 1988, Development of SCF formulae and generalised influence
11 functions for use in fatigue analysis. OTJ88.

Release 15.0 - SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
128 of ANSYS, Inc. and its subsidiaries and affiliates.