You are on page 1of 62

S'il vous plat lisez

attentivement ce manuel avant


d'utiliser ce dispositif

BX10 Plate-forme de services intgrs


MODE D'EMPLOI
Ver2.0

BX10 Plate-forme de services intgrs


Paru en: Sept., 2006

Il n'y aura aucun autre avis sur la modification priodique de cette publication, ainsi que

l'amendement sera complt la publication. Je vous remercie de slectionner BX10

plate-forme de services intgrs!


Table des matires

Safe Operation Notice................................................................................................ 1


Chapter One BX10 Integrated Service Platform.................................................. 1
1.1 Description du Produit.................................................................................. 1
1.2 Caractristiques du produit....................................................................... 1
1.3 Fonctions du produit..................................................................................... 1
1.4 Module d'affectation..................................................................................... 2
1.5 Applications typiques.................................................................................. 2
1.6 Les objectifs techniques.............................................................................. 2
Chapitre Deux Introduction Equipement................................................................ 6
2.1 Modles d'quipements.................................................................................. 6
2.2 power board................................................................................................... 7
2.3 MCUS.......................................................................................................... 9
2.4 NMC.......................................................................................................... 15
2.5 E1PS.......................................................................................................... 15
2.6 CHUPS....................................................................................................... 18
2.7 DATA.......................................................................................................... 32
chapitre trois lignes de dpart.............................................................................. 42
3.1 2M lignes de dpart of MCUS................................................................ 42
3.2 2M lignes de dpart of E1PS.................................................................... 43
3.3 Cable VF................................................................................................... 45
3.4 Cable E/M VF............................................................................................ 47
3.5 Cable 10BASE-T..................................................................................... 49
3.6 Cable RS232/485 Data.............................................................................. 50
3.7 Cable DataV35......................................................................................... 51
3.8 Cable DataV35 and 10BASET................................................................ 53
3.9 Suivi de cableRS232/485 ........................................................................... 54
3.10 -48 Cable dAlimentation.................................................................... 55

1 , 1
BX10 Integrated Service Platform

Safe Operation Notice

Cet quipement fonctionne bien quand ils sont utiliss comme prvu, tandis que le prjudice
ou des dommages artificielle doivent encore tre vites.
- Lisez attentivement ce manuel et le conserver ainsi pour rfrence ultrieure.
- Gardez l'appareil hors de source d'eau ou endroit humide.
- Ne rien placer sur le cble d'alimentation et le garder hors de la porte accessible
- Ne pas faire des noeuds ou enfer les cbles pour viter les risques d'incendie.
- Faire des inspections rgulires pour s'assurer que les branchements lectriques et les pices
de raccordement d'autres quipements sont relis de faon sre
- Faites attention la majoration de la borne de cblage lors de la connexion du cble
d'alimentation (l'extrmit noire est lie la polarit ngative, le rouge est connect avec la
polarit droite.
- L'alimentation doit rpondre aux conditions suivantes:
DC -48V-36V -72V
AC220V220V10, 50Hz
- Dbranchez immdiatement l'alimentation et contacter le Service Aprs-vente
Dpartement de la socit dans les cas suivants.
Pntration de l'eau;
Crash de l'quipement ou revtement;
Fonctionnement anormal ou changement de performance;
Mauvaise odeur, fume ou bruit dans l'quipement.
- S'il vous plat garder l'quipement propre et essuyez avec un chiffon en coton doux si
ncessaire.
- Laissez le ventilateur ouvert.
- Ne pas rparer l'quipement par vous-mme sauf s'il est clairement indiqu dans le guide.

1 , 1
BX10 Integrated Service Platform

Chapitre un BX10 Plate-forme de services intgrs

1.1 Description du produit


BX10 Plateforme intelligent Service Intgr
Intgre l'accs numrique/analogique, multiplexage, cross-connection, transmission
et fonctions de conversion de protocole avec de puissante matrice dans le noyau. Il
construit une plate-forme unifie de l'quipement srie dans une structure standard
en combinant les types de service des rseaux d'accs. Il fournit GV / GE / DXC /
rseaux PCM et la mixit des fonctions de tous les modules sur des plateformes
telles que l'approvisionnement en puissance publique, l'administration rseau, la
connexion transversale et la carte mre, et l'intgre large bande et bande troite.
Par le protocole SNMP, l'tat de communication de l'ensemble du rseau pourrait
tre suivi en temps rel.
1.2 Caractristiques du produit
Il intgre des fonctions telles que l'accs digit/analogue, multiplexage, cross
connexion, transmission et conversion de protocoles;
IL y a bien quelques modles et les 4U, 2U et 1U modles sont compatibles les uns
avec les autres pour le renforcement des pratiques d'expansion;
Interfaces riches: POTS, 10Base-T, V.35, RS232, RS485, etc.;
Disposition flexible, le brancher dans n'importe quel emplacement et au libre choix
de cartes d'interface;
Branchement et dbranchement chaud ;
Power supply warm standby
Open bus and rich user interfaces for adding new services;
Flexible networking: chain, tree, star and ring-type networked;
Intelligent network administration system: human-based management,
accurate localization of fault, distributed management, etc;
64E1 crossing and supporting CAS signaling crossing;
Chssis de la machine standard compatible avec BX tableaux de connexions
autonome.

1.3 Fonctions du produit


L'accs vocal l'aide dinterfaces de signalisation diversifie :
Tlphone automatique, Interface E/M, Phonie 2W/4W, etc.
L'accs aux donnes via des interfaces de donnes diversifies:
Base10-T, V.35, RS232/485, etc.
Notice: RS232 data port doit tre bien mis la terre ou un isolateur port srie
est ajout afin que le port RS232 des donnes ne sera pas brl.

1 , 40
BX10 Integrated Service Platform

Interfaces de transmission optiques, y compris PDH:


PDH terminal de fibre optique: 4 x E1.
Cross connexion, structure tableau de connexion E1:
64E1 crossing and supporting CAS signaling crossing.
Converter pool:
10Base-T, V.35 converter pool.
Centralized network administration:
Whole net monitoring and SNMP support.

1.4 Module Allocation

MCUS provides 4 E1 interfaces and Ethernet monitoring card could be


adopted to realize whole net monitoring.
The voice channels are allocated by two and 8 channels may be allocated to
each board at most, 104 channels for the 4U model in full.
The data channels (10/100Base-T, V.35) are allocated by one and 4 channels
could be allocated to one board at most, 52 channels for the 4U model in full.
The RS232 485 data channels are allocated by two and 8 channels
may be allocated to each board at most, 104 channels for the 4U model in full.
Each board provides 8 E1 interfaces (64 for 4U model at most) for realizing
64xE1 time slot crossing and signaling crossing.

1.5 Typical Applications

MAN construction
Large client integrated services access
3-in-1 network construction
Intelligent zone construction
DDN network extension
Mobile base station construction
Development of telecommunications services by making use of the existing
CATV network
Construction of the wiring network layer of the access network
Rural telecom network reconstruction
Replacement of the PDH and SDH optical transmission equipment
Emergency Communication
La construction du rseau d'information des armes

1.6 Les objectifs techniques

Interface type Technical Indicators


POTS Mode de codage A-law

2 , 40
BX10 Integrated Service Platform

interface Dbit 64Kbps


distant DC loop resistance 2000
(Max.)
Effective 300-3400Hz/600
transmission
bandwidth
Frequency characteristics
300Hz400Hz -0.3~ -0.1dB
400Hz2400Hz -0.2~ 0.1dB
2400Hz 0~0.7dB
3400Hz
Unbalanced to earth
300Hz600Hz 40dB
600Hz3400Hz 46dB
Idle channel noise <-67dB
Ringing current
253Hz, 7515V
voltage
POTS local Encoding mode A-law
interface Bit rate 64Kbps
DC loop resistance 2000
(Max.)
Effective 300-3400Hz/600
transmission
bandwidth
Frequency characteristics
300Hz400Hz -0.3~ -0.1dB
400Hz2400Hz -0.2~ 0.1dB
2400Hz 0~ 0.7dB
3400Hz
Unbalanced to earth
300Hz600Hz 40dB
600Hz3400Hz 46dB
Idle channel noise <-67dB
Group-path Impedance 75 unbalance /120 balance
interface matching
Interface code HDB3

3 , 40
BX10 Integrated Service Platform

Nominal bit rate 2048Kb/s50ppm


and allowance
Nominal wave form 2.37V0.237V/75(unbalance)
amplitude
Insertion loss: the attenuation is 0-6dB at 1024KHz
Audio Total distortion Conforming to ITU-T G.713
interface Frequency Conforming to ITU-T G.713
Level Conforming to ITU-T G.713
Effective 300~3400 Hz/600
transmission
bandwidth
Audio transmission 2W/4W
mode
2W receive 0dBr/600 -14dBm~
+17.5dBm, adjustable)
2W transmit -3.5dBr/600 -31.5dBm~
0dBm, adjustable
4W receive -14dBr/600 -14dBm~
+17.5dBm, adjustable
4W transmit +4dBr/600 -27.5dBm~
+4dBm, adjustable
Level adjustment 0.5dBm
step
Overload level +3.14dBm
E&M Internal resistance When put to earth 2010%
interface When in open circuit 100 K
Sampling frequency 500Hz
Pulse distortion 2.5ms
Clock rate 500Hz 8KHz
Encoding rule 1 when in open circuit; 0 when put to
earth
Resistance 600 2W, 4W receive, 4W
transmit)
M-line detection 5mA
sensitivity
E-line output 50mA
current
V.35 interface Nominal bit rate N64k N is 1~31

4 , 40
BX10 Integrated Service Platform

Port mode DCE/DTE


Framing or non-framing, internal or external clock or circuit
(optional)
10BaseT Supported protocol Conforming to IEEE 802.3
interface Physical interface RJ45
Interface rate N64k N is 1~31
BX120 System capacity 4E1
Optical Optical transmitting -5~ -12dBm
module power
Optical reception -36dBm
sensitivity
Type of optical FC
fiber connector
Input impedance 75/120
Signaling The 16th time slot channel associated signaling, conforming
mode to ITU-T G.732
Power supply Power source -48VDC -36V~-72V or
220VAC 165V~265V
Power consumption <= 3w (for audio multiplexing)
The peak power output of the ringing current module: 30W
Machine case 19" wide and 4U, 2U or 1U high
structure 16 slots in all, of which 14 are in common use
Working Temperature 5~50
environment Humidity 90%
Air pressure 86~106Kpa

5 , 40
BX10 Integrated Service Platform

Chapter Two Equipment Introduction

2.1 Equipment Models

There are quite a few models adopting the plugboard architecture and the 4U,
2U and 1U models are compatible with each other for convenient capacity-
expansion;
(1) 4U model (BX10-4U):

4U: height; 19: width; 300mm: depth.


It applies to the central office end with 16 slots, 14 of which are for functional
boards and 2 for power boards in warm standby.
(2) 2U model (BX10-2U):

2U: height; 19: width; 300mm: depth.


It applies to the remote end with 6 slots. The power board does not utilize the
slot and no warm standby is provided.
(3) 1U model (BX10-1U):

6 , 40
BX10 Integrated Service Platform

1U: height; 19: width.


10 service slots (6 data slots and 4 voice slots). The data interfaces, such as
V.35, 10/100Base-T, Rs232 and Rs485, and voice interfaces are supported;
one main service slot, and the main service may be provided through 1 E1, 2
E1, 3 E1, 4 E1 and 120 optical terminal card; one network layer management
card (Ethernet Interface management card or Rs232/485 interface
management card).

2.2 power board

(1) 4U power board :


It applies to 4U machine case and 2 power boards could be plugged in for
warm standby. There is power indicator on the front panel, indicating the
operating state of the power supply.

7 , 40
BX10 Integrated Service Platform

A.4U no-ring current power board BX10-PWRS-4UL


Input: DC 36 ~ 72V
Function: DC/DC switchover for powering the system.

8 , 40
BX10 Integrated Service Platform

Output: +5V, -5V, -48V Power feed.


b. 4U remote power board BX10-PWRS-4UR
Input: DC 36 ~ 72V
Function: DC- 48V is converted to AC 75V ringing current for powering the
system.
Output: +5V, - 5V, ringing current, - 48V power feed.
(2) 2U power board:
>It applies to 2U machine case and only one power board can be plugged (no
warm standby).

a. 2U no-ring current power board BX10-PWRS-2UL


Input: DC 36 ~ 72V AC 220V
Function: power the system through DC/DC switchover.
Output: +5V, - 5V,- 48V power feed.
b. 2U remote power board BX10-PWRS-2UR
Input: DC 36 ~ 72V AC 220V

9 , 40
BX10 Integrated Service Platform

Function: DC- 48V is converted to AC 75V ringing current for powering the
system.
Output: +5V, - 5V, ringing current, - 48V power feed.

1. 2.
2. Network monitoring card can be provided to monitor the whole net, and
the monitoring channel time slots and backup bits are optional.

There are four built-in E1 interfaces. 3 MCUS

Functional Description:
3. It is the system control center for monitoring and resource allocation.
4. It contains the very-large-scale integrated circuit with built-in
20482048 cross matrix for realizing the free crossing of 64 E1 time
slots.
5. The system conducts self-check automatically and the problems will be
reported in time for fault location.
Functional Interfaces:

MCUS Layout
LED Indicator
JP1, JP2 Address switch
JP5 Side wheel switch
J5 Monitoring port 1

10 , 40
BX10 Integrated Service Platform

S21 Reset switch


S20 Program switch
S16-S19 Resistance
S1-S12 E1 Setup
J1 E1 interface

1. E1 interfaces:
1) Position: (J1) DB37 hole-type plug.
2) Interface: balance - DB37 hole-type plug, unbalance - CC4A
coaxial socket
3) Providing 4E1 interfaces and refer to the Appendix for the outgoing
lines.
4) Supporting balance and unbalance modes.
5) Supporting multiple signaling modes:
CAS the subscriber signaling are crossed automatically.
CCS: in this mode, TS16 time slot could be used to transmit the
user services.
6) Supporting CRC - 4 test.
7)Providing monitoring channels: the time slots and backup bits are
optional.
2. Monitoring interface:
1) Position (J4) DB9 hole-type plug, RS232/485 monitoring;
(J5) RJ45 plug, Ethernet monitoring.
2) See "Appendix: Outgoing lines of monitoring ports" for the
outgoing lines of each monitoring port.
3) The RS232 monitoring transmission rate is 9600bps, and the
transmission distance is 15m.
4) The RS485 monitoring transmission rate is 9600bps, and the
transmission distance is 800m.
5) The Ethernet monitoring transmission rate is 10/100Mbps and
the transmission distance is 100m.
3. Indicator lights:

11 , 40
BX10 Integrated Service Platform

4. Switch setting:
1) Reset button:
Position: S21.
Function: press it to reset CPU.
2) Program switch:

Position: S20.
Function: program selection.
Set the short circuitor near S20
3) Side tumble switch:
Position: JP5.

12 , 40
BX10 Integrated Service Platform

SW1 OFF ON ON OFF


SW2 OFF OFF ON ON
LED alarm indicator
RLS AIS MFLA CMFLA
FLA RA MRA CMA
SW3 RS232 monitor mode RS485 monitor mode
ON OFF
SW4 Reserved

See the following table to interpret the indicator lights:


Name of Meaning
indicator
light
NET Constant on: network monitoring card is provided; constant off:
no network monitoring card is provided.
RUN Flicker: MCUS is in working order; no flicker: MCUS is out of
working order
LINK Constant on: the net wire connection of the network monitoring
card is normal; constant off: abnormal connection (the standard
configuration is invalid)
MRUN Flicker: the network monitoring card is in working order; no
flicker: abnormal operation (the standard configuration is
invalid)
TEST Reserved
MA Reserved
RLS1-4 Constant on: 2M signal reception loss; off: normal 2M signal
reception
FLA1-4 constant on: Out of frame of 2M signal frames; off: normal
reception of 2M signal frames
AIS1-4 constant on: Reception of all "1" 2M signals; off: normal 2M
signal reception
RA1-4 constant on: Alarm for the 2M signal reception at the opposite

13 , 40
BX10 Integrated Service Platform

end; off: normal 2M signal reception at the opposite end


MFLA1-4 constant on: Out of step reception of 2M signal multi-frames;
off: normal reception of 2M signal multi-frames
MRA1-4 constant on: Out of step reception of 2M signal multi-frames at
the opposite end; off: normal reception of 2M signal multi-
frames at the opposite end
CMFLA1-4 constant on: Out of step reception of 2M signal CRC4 multi-
frames; off: normal reception of 2M signal CRC4 multi-frames
CMRA1-4 constant on: Out of step reception of 2M signal CRC4 multi-
frames at the opposite end; off: normal reception of 2M signal
CRC4 multi-frames at the opposite end

Notice: 1-4 refer to the four 2M ports on the backboard: 2M 1- 2M4, and
only two lights ( RLS1 FLA1) for the alarm of the first E1 are
concerned in the standard configuration and others are reserved. Other
alarm information could be viewed through the thumb wheel dial (SW).
4) Address switch:

*Note: The abbreviated drawing of JP1 and JP2 switches on MCUS


is provided
Position: JP1 and JP2 top tumble switches.
Function: JP1 is for network address setting and JP2 is for unit address
setting. ON is "1" and OFF is "0".
5) RS485 Resistance:

14 , 40
BX10 Integrated Service Platform

Position: S16 S17 S18 S19.


Function: Access RS485 matched resistance at side Y and not access
matched resistance at side N.
6) E1 port setting:
A. Balance mode setting:

S5-S12, it is unbalance mode if short circuitor is applied, otherwise, it is


balance mode.
B. Interface impedance setting:

S1-S4: it is 75ohm at the side printed with 75 and 120ohm at the side

15 , 40
BX10 Integrated Service Platform

printed with 120.

2.4 NMC

Functional Description:
1. Realizing whole net monitoring (compatible with BX06 equipment)
through intercommunication between BX10 equipment.
2. If this card is not added to MCUS, only local monitoring can be
realized.
3. Supporting Ethernet, RS232, RS485 monitoring.
4. Supporting SNMP.
5. Refer to "BXView 4 Network Administration User Manual" for the
network administration software.

2.5 E1PS

Functional description
1. Each board provides 8 channels, and the 4U model could provide 8
boards to realize 64 channels and to realize the complete crossing of
64E1 time slots. The 2U model could provide 5 boards to realize 44
channels (the main control board may provide 4 channels).
2. E1 interface supports the CAS and CCS signaling modes.
3. E1 interface supports the balance and unbalance modes.
Functional Interfaces:

16 , 40
BX10 Integrated Service Platform

LED Indicator
S33 Side wheel
switch
S32 Reset switch
S4~S2 E1 port setup 1
7
J5 E1 Interface
1. E1 interface
1) Position: (J5) DB62 hole-type plug.
2) Interface: balance - DB62 hole-type plug, unbalance- CC4A
coaxial DB62 hole-type plug.
3) Providing 8E1 interfaces and refer to the Appendix for the outgoing
lines.
4) Supporting balance and unbalance modes.
5) Supporting multiple signaling modes:
6) CAS the subscriber signaling are crossed automatically.
7) CCS: in this mode, TS16 time slot could be used to transmit the user
services.
8) Supporting CRC-4 verification..
9)Providing monitoring channels: the time slots and backup bits are
optional.
2. E1 port setting:

17 , 40
BX10 Integrated Service Platform

A. Balance mode setting:

S4-S19 it is unbalance mode is short circuitor is applied to side N or


balance mode is short circuitor is applied to side Y.
B. interface impedance setting:

18 , 40
BX10 Integrated Service Platform

S20-23, S24-S27, it is 75ohm at the side printed with 75 and 120ohm at


the side printed with 120.
3. Indicator lights

19 , 40
BX10 Integrated Service Platform

2.6 CHUPS

The voice services provided by BX10 Integrated Service Platform are realized
by the CHUPS and corresponding service interface cards. The CHUPS is in
charge of data send-receive, data processing and network management
information arrangement, and the interface cards provides interfaces to the
voice service equipment, such as telephone sets, magnet telephone sets,
exchanges, etc. The service interface cards convert the real line signaling and
voice signals sent from different equipment to digital signals and send them to
the CHUPS, where they shall be processed and sent to the opposite end. At the
opposite end, such signals will be restored to the real line signaling and analog
speech signals that could be identified by the user equipment in order to
complete the call duration and voice transmission. The service interface cards
include the 2W4WCHUC, CHUFXOC, CHUFXSC, EMC, MAC and CARC
according to the services provided.
The indicator lights on the panel are as follows:

20 , 40
BX10 Integrated Service Platform

The indicator lights on the front panel of the CHUPS are defined as follows:
RUN: it flickers when the program runs normally and it is off when the
program does not run normally.

21 , 40
BX10 Integrated Service Platform

1-8: the voice channel is utilized when the light is constantly on, and it is idle
when the light is off.
Each board could provide the access to 8 channels of voice service.
Classification:
CHUPS BX10_CHUPS
2W4WCHUC BX10_2W4WCHUC
CHUFXOC BX10_CHUFXOC
CHUFXSC BX10_CHUFXSC
EMC BX10_EMC
MAC BX10_MAC
CARC BX10_CARC
Applications:
CHUPS: it provides various services with cards plugged and it could provide
8 voice channels at best.
2W4WCHUC: each card provides 2 2W/4W voice channels with adjustable
attenuation as well as the independent VF channel.
CHUFXOC and CHUFXSC: Automatic station set signalling card
common telephone interface is provided, and CHUFXOC is adopted for the
connection with the exchange and CHUFXSC is used for the connection with
the user telephone. Each card provides 2 ways of 2W voice channels with
fixed attenuation.
EMC: provide one way E/M signalling interface (1E1M- 2E2M, type 1-5) and
one way 2W/4W voice channel with adjustable attenuation.
MAC: provide magnet telephone interface. Each card provides one channel.
CARC: Provide the interface for conversion from 2W carrier wave interface
2100hz signaling to 25Hz ringing current. One channel for each card.
Functions:
BX10_CHUPS
1. Service configuration through communication with the network

22 , 40
BX10 Integrated Service Platform

management system.
2. Data transmission via communication with the bus.
3. Processing voice and signaling information.
4. Supplying power to each service card, conducting data exchange and
providing outgoing lines to various service interfaces.
BX10_2W4WCHUC
1. Realizing the switchover between digital signals (A-law, PCM) and
analog voice signals.
2. Providing 2 VF channels or two 2/4W analog private line interface
channels without signaling.
3. The 2/4W switchover of each VF channel could be set separately.
4. Realizing the loop-back of all VF channels under the control of loop-
back signals.
5. Providing the line protection function to prevent the interfaces from
being damaged by lightning or the clash between the subscriber line
and other power lines.
6. Adjusting the transmission level of the receive side and transmit side of
the 2/4W respectively through the jumpers.
BX10_CHUFXOC
1. Providing two channels of 2W telephones with automatic central office
end signaling.
2. Serving as the common analog station set to restore the remote off-hook
and hang-up signals.
3. Restoring the remote end dial pulses.
4. Detecting the ring signals on the exchanger subscriber line, converting
them to digital signaling and supplying them to MCUS.
5. Displaying the utilization of channels.
6. Supporting the function of "Calling Identity Delivery".
BX10_CHUFXSC

23 , 40
BX10 Integrated Service Platform

1. Providing two channels of 2W telephones with automatic station set


remote signaling.
2. Being equivalent to the subscriber module of exchange and providing
station set feed and ring current.
3. Detecting the on-hook, off-hook and pulse dialing signals from the
subscriber line, converting them to the digital signaling and supplying
them to MCUS.
4. Indicating the working order of the user port.
5. The maximum allowable loop resistance is 2000.
BX10_EMC
1. Completing the switching from E & M signaling to digital signaling
and supplying the digital signaling to the MCUS.
2. Providing one channel of E & M (from 1E1M to 2E2M) signaling port.
3. Providing one 2/4W voice channel with adjustable attenuation.
4. Each port could be configured to Type I, II, III, IV or V E& M
interface.
5. Providing the port status indication.
BX10_MAC
1. Completing the switching from magnet signaling to digital signaling;
2. Providing one channel of magnet telephone interface;
3. Providing the port status indication.
BX10_CARC
1. Detecting and restoring the carrier wave in-band 2100Hz signaling;
2. Detecting and restoring the 25Hz ring current signaling of the magnet
interface;
3. Providing one channel of 2W carrier wave switching interface at the
same time;
4. Indicating the port status.
Operating Instructions:

24 , 40
BX10 Integrated Service Platform

The CHUPS will provide voice service jointly with corresponding service
interface cards, thus the operating instructions are introduced by the service
interface card.

BX10_2W4WCHUC
1. 2W/4W VF channel setting switch
2. Setting the channels to work in 2W or 4W mode.
3. VF channel send and receive relative level setting switch
4. 2W/4W mode selector
The voice channel may be set to 2W or 4W work mode by changing the
position of the mode conversion switch. The work mode of voice channel 1
may be set through S5 and that of voice channel 2 through S6, as shown
below:
Channel 1: 4W mode Channel 2: 4W mode
S5 S6

Channel 1: 2W mode Channel 2: 2W mode


S5 S6

Relative level setting switch


For each VF channel, there are transmit level setting switches and receive
level setting switches in two groups (24-pin jumpers) (channel 1 is
corresponding to S1 and S2; channel 2 is corresponding to S3 and S4), the
regulating range is 0- 31.5dB, and the regulating step is 0.5dB.

25 , 40
BX10 Integrated Service Platform

The attenuator is composed of 6-section resistor network and the attenuation


of each section is 0.5db, 1db, 2db, 4db, 8db, 16db respectively. Each section
is corresponding to two lines of contact pins and the attenuator of certain
section is switched on if the pins are plugged into the lower part of the
switch. The sum of the attenuation of all sections is the attenuation of the
whole attenuator.
The 2W4WCHUC is in 2W mode in default, whose transmit level is 0dBr
and receive level is - 3.5dBr. The voice channel setting may be changed as
follows:

26 , 40
BX10 Integrated Service Platform

R S1 T S2
2W receive level attenuation setting (attenuation 4dB); 2W transmit level
attenuation setting (attenuation 14dB);

R S1 T S2
4W receive level attenuation setting (attenuation 0dB); 4W transmit level
attenuation setting (attenuation 0dB);
(Note: R represents the receiving end, T represents the transmitting end. The
setting of another voice channel is similar and S3 and S4 will be set
correspondingly.)

27 , 40
BX10 Integrated Service Platform

The transmit and receive levels of 2W/4W is suggested adopt the


default setup.

BX10_FXOC
It has level adjusting switches at the transmit and receive directions. There are
4 jumpers in the vertical direction, forming the upper group and lower group.
The upper groups are regulating switches in the transmitting direction and the
lower groups are the regulating switches for the receiving direction. 4dB
interface level attenuation could be added to corresponding direction via the
regulating switches. See the following figures for the position of the short
circuitor and it is 0dB level attenuations.

When the short circuitor is plugged on 3, 4dB interface level attenuation is


added to the transmit direction of voice channel 1; if it is plugged on 2, 4dB
interface level attenuation is added to the receive direction of voice channel 1.
When the short circuitor is plugged on 7, 4dB interface level attenuation is
added to the transmit direction of voice channel 2; if it is plugged on 6, 4dB
interface level attenuation is added to the receive direction of voice channel 2.

28 , 40
BX10 Integrated Service Platform

The indicator lights on the panel indicate the channel status.

BX10_FXSC
It has level adjusting switches at the transmit and receive directions. There are
4 jumpers in the vertical direction, forming the upper group and lower group.
The upper groups are regulating switches in the transmitting direction and the
lower groups are the regulating switches for the receiving direction. 4dB
interface level attenuation could be added to corresponding direction via the
regulating switches. See the following figures for the position of the short
circuitor and it is 0dB level attenuations.

When the short circuitor is plugged on 3, 4dB interface level attenuation is


added to the transmit direction of voice channel 1; if it is plugged on 2, 4dB
interface level attenuation is added to the receive direction of voice channel 1.
When the short circuitor is plugged on 7, 4dB interface level attenuation is
added to the transmit direction of voice channel 2; if it is plugged on 6, 4dB
interface level attenuation is added to the receive direction of voice channel 2.
The channel status is shown through the panel indicators.

29 , 40
BX10 Integrated Service Platform

BX10_EMC
The meanings of the panel indicator lights are the same as that of CHUFXOC
and CHUFXSC.
EMC decides to use which one of the five types of cards through jumper
switch.
The way of setting single channel of EMC is given below and it is the same
for the remote end. Take 1E1M as an example, A3, A4, A6, A7, A8 are the
common control switches of E1M1 and E2M2. It is the same for the 2E2M
setting.
A. Set it to the first type of EM: apply short circuitor to A3; do not apply short
circuitor to A4, A6, A7 and A8; plug short circuitor into the lower half of
SW1. Line E and line F of this board are connected with line E and line M of
the exchange respectively, and E is connected with M, M with E and SB with
SG when connecting with user equipment, as shown in the right figure:

The short circuitor of SW1 is set as follows:

30 , 40
BX10 Integrated Service Platform

B. set it to the second type of EM: apply short circuitor to A7; do not apply
short circuitor to A3, A4, A6 and A8; plug short circuitor into the lower half of
SW1. Line E and line M of this board are linked with line E and line M of the
exchange directly, and SG and SB are connected with the SG and SB of the
exchange directly. When connecting with the user equipment, E is connected
with M, M is connected with E and SB and SG lines are connected directly, as
shown below:

The short circuitor of SW1 is set as follows:

31 , 40
BX10 Integrated Service Platform

C. set it to the third type of EM: apply short circuitor to A3 and A7; do not
apply short circuitor to A4, A6 and A8; plug short circuitor into the lower half
of SW1. Line E and line M of this board are linked with line E and line M of
the exchange directly, and SG and SB are connected with the SG and SB of
the exchange directly. When connecting with the user equipment, E is
connected with M, M is connected with E and SB and SG lines are connected
directly, as shown below:

The short circuitor of SW1 is set as follows:

32 , 40
BX10 Integrated Service Platform

D. set it to the fourth type of EM: apply short circuitor to A6; do not apply
short circuitor to A3, A4, A7 and A8; plug short circuitor into the upper half of
SW1. Line E and line M of this board are linked with line E and line M of the
exchange directly, and SG and SB are connected with the SG and SB of the
exchange directly. When connecting with the user equipment, E is connected
with M, M is connected with E and SB and SG lines are connected directly, as
shown below:

The short circuitor of SW1 is set as follows:

33 , 40
BX10 Integrated Service Platform

E. Set it to the fifth type of EM: apply short circuitor to A3; do not apply short
circuitor to A4, A6, A7 and A8; plug short circuitor into the upper half of
SW1. Line E and line M of this board are linked with line E and line M of the
exchange directly, and SG and SB are connected with the SG and SB of the
exchange directly. When connecting with the user equipment, E is connected
with M, M is connected with E and SB and SG lines are connected directly, as
shown below:

The short circuitor of SW1 is set as follows:

34 , 40
BX10 Integrated Service Platform

The exact arrangement of E/M is also shown on the sick screen print of the
EMC.
Notice:
The EMC may be set to certain type by strictly following the aforementioned
method and it should be checked carefully. The machine board may be burnt if
the short circuitor is wrongly plugged! It is strictly prohibited to plug and pull
the EMC.

BX10_MAC
Like 2W4WCHUC, MAC also has transmit level setting switches and receive
level setting switches (24 pin jumpers-S1, S2). The transmit level and the
receive level could be adjusted respectively and the way of level setting is the
same as that for 2W4WCHUC (Note: only 2W mode is provided and there is
no 4W mode)

BX10_CARC
Like 2W4WCHUC, CARC also has transmit level setting switches and
receive level setting switches (24 pin jumpers-S1, S2). The transmit level

35 , 40
BX10 Integrated Service Platform

and the receive level could be adjusted respectively and the way of level
setting is the same as that for 2W4WCHUC (Note: only 2W mode is provided
and there is no 4W mode)

2.7 DATA

Classification: DATA, 10BASE-T Ethernet interface card, RS232/485 data


interface card, V.35 synchronous data interface card.

2.7.1 DATA

Functional Description:
1. Each DATA provides four slots for V.35 data interface card, 10BASE -
T Ethernet interface card and RS232/485 data interface card.
2. The DATA does not provide any interface, but it may be added with
interface cards. For instance, it could provide V.35 interface with v.35
data interface card plugged, RS232/485 data interface with RS232/485
interface card plugged and 10BASE-T Ethernet interface with
10BASE-T Ethernet interface card plugged. The above three kinds of
cards may be plugged into the same data interface board. The data
board could provide four V.35 interfaces, four 10BASE - T Ethernet
interfaces and eight RS232/485 interfaces at most.
Notice: RS232 data port should be well grounded or serial port isolator
is added so that RS232 data port will not be burnt out.
3. V.35 data interface and 10BASE-T Ethernet interface could be set to
N64k (n=1-31) dynamic data channel. RS232/485 data interface may
be set to 64K data channel.

Functional Interfaces:

36 , 40
BX10 Integrated Service Platform

Note: if DB26- RJ45 switch is applied to V.35, RS232 or RS485 interface,


the DATA could provide 10Base-T interface.

37 , 40
BX10 Integrated Service Platform

Description of indicator lights


1. Plug V.35 synchronous data interface card into the DATA
RUN Program run indicator flicker normal
light program run
off abnormal
program run
RXD1 channel 1 receive flicker channel 1 is
data receiving
data
off idle

38 , 40
BX10 Integrated Service Platform

L/D1 channel 1 transmit flicker channel 1 is


data transmitting
data
off idle
RXD2 channel 2 receive flicker channel 2 is
data receiving
data
off idle
L/D2 channel 2 transmit flicker channel 2 is
data transmitting
data
off idle
RXD3 Channel 3 receive flicker channel 3 is
data receiving
data
off idle
L/D3 Channel 3 transmit flicker channel 3 is
data transmitting
data
off idle
RXD4 Channel 4 receive flicker channel 4 is
data receiving
data
off idle
L/D4 Channel 4 transmit flicker channel 4 is
data transmitting
data
off idle

2. Plug RS232/485 data interface card into the DATA


RUN Program run indicator flicker normal
light program run

39 , 40
BX10 Integrated Service Platform

off abnormal
program run
RXD1 channel 1 receive flicker channel 1 is
data receiving
data
off idle
L/D1 channel 2 receive flicker channel 2 is
data receiving
data
off idle
RXD2 Channel 3 receive flicker channel 3 is
data receiving
data
off idle
L/D2 Channel 4 receive flicker channel 4 is
data receiving
data
off idle
RXD3 Channel 5 receive flicker channel 5 is
data receiving
data
off idle
L/D3 Channel 6 receive flicker channel 6 is
data receiving
data
off idle
RXD4 Channel 7 receive flicker Channel 7 is
data receiving
data
off Idle

40 , 40
BX10 Integrated Service Platform

L/D4 Channel 8 receive flicker Channel 8 is


data receiving
data
off idle

3. Plug 10BASE-T Ethernet interface card into the DATA


RU Program run indicator flicker normal program run
N light Off abnormal program run
RX channel 1 receive data flicker channel 1 is receiving data
D1 Off idle
L/D channel 1 Ethernet port On normal connection of
1 connection Ethernet port of channel 1
Off Disconnection of channel 1
Ethernet port
RX channel 2 receive data flicker channel 2 is receiving data
D2 Off Idle
L/D channel 2 Ethernet port On normal connection of
2 connection Ethernet port of channel 2
Off Disconnection of channel 2
Ethernet port
RX channel 3 receive data flicker channel 3 is receiving data
D3 Off Idle
L/D channel 3 Ethernet port On Normal connection of
3 connection Ethernet port of channel 3
Off Disconnection of channel 4
Ethernet port
RX channel 4 receive data flicker channel 4 is receiving data
D4 Off Idle
L/D channel 4 Ethernet port On Normal connection of
4 connection Ethernet port of channel 4
Off Disconnection of channel 4
Ethernet port

41 , 40
BX10 Integrated Service Platform

2.7.2 RS232/485 Data Interface Card

Functional Description:
1. Each card provides 2 channels of low-speed RS232 asynchronous
interface (19.2Kb/s) or two channels of RS485 data interface.
2. Each way utilizes one time slot, which may be set by the network
management software freely
3. Each channel provides the transmit and receive circuits
4. The number of RS232/485 data interface cards may be configured as
required, 20 at most for 2U machine case and 52 at most for 4U
machine case.

Switch setting of RS232/485 data interface cards:


1. RS232/485 interface mode setting:

Position: S3, S4, S5, S6, S7, S8


Function: It is RS232 mode by placing short circuitor at the side with RS232
printed or RS485 mode by placing short circuitor at the side with RS485
printed.
Note: S3, S5, S7 are switches for the setting of channel 1. S4, S6, S8 are

42 , 40
BX10 Integrated Service Platform

switches for the setting of channel 2.

2. RS485 matched resistance setting:

Position: S9, S10, S11, S12


Function: It is the mode with matched resistance by placing short circuitor at
the side with Y printed or the mode without matched resistance by placing
short circuitor at the side with N printed.
Note: S9 and S10 are switches for the setting of channel 1. S11 and S12 are
switches for the setting of channel 2.

3. RS485 self-adaptation enabling setting:

Position: S1, S2
Function: place the short circuitor at different positions to enable the self-
adaptation in RS485 mode or disable it. When it is enabled, it will judge
whether there is RS485 data or not, and open the data channel if there is.
Way of setting: enable it by placing the short circuitor at the side with Y
printed, or disable it by placing the short circuitor at the side with N printed.

43 , 40
BX10 Integrated Service Platform

Note: S1 is the channel 1 setting switch and S2 is the channel 2 setting switch.

2.7.3 V.35 synchronous data interface card

1. Each card provides one channel of N64Kb/s V.35 synchronous


interface
2. Each channel may utilize N time slots ( 1N31), and the time slots
may be set freely through the network management software.
3. Each channel provides the transmit and receive circuits
4. The number of V.35 synchronous data interface cards could be
configured as required, 20 at most for 2U machine case and 52 at most
for 4U machine case.

2.7.4 10BASE-T Ethernet interface card

1. Each card provides one 10BASE - T Ethernet interface


2. Each channel may utilize N time slots ( 1N31), and the time slots
may be set freely through the network management software.
3. Each channel provides the transmit and receive circuits
4. The number of 10BASE-T Ethernet interface cards could be configured
as required, 20 at most for 2U machine case and 52 at most for 4U
machine case.
Switch setting of 10BASE-T Ethernet interface card:

Position: S top tumble switch.

44 , 40
BX10 Integrated Service Platform

Function: S refers to the Ethernet work mode, and there are 8 switches in all,
of which switch 7 and switch 8 are idle.
Note:
1. Switch 1: for DHCP filter setting (OFF: enable; ON: disable).
2. Switch 2: for NetBIOS filter setting (OFF: enable; ON: disable).
3. Switch 3 for repeater mode setting (OFF: enter repeater mode;
ON: not).
4. Switch 4 for velocity setting (OFF: 100MHz; ON: 10MHz)
5. Switch 5 for transmission mode setting (OFF: full duplex mode;
ON: half-duplex mode)
6. Switch 6 for the self-adaptation setting (OFF: self-adaptation; ON: no self-

adaptation). (when it is set as self-adaptation, switch 4 and switch 5 should be

turned to OFF))

45 , 40
BX10 Integrated Service Platform

Chapter Three Outgoing Lines

3.1 2M Outgoing Lines of MCUS

MCUS DB37-RJ45 cable


ID: DB37-4RJ45
No.: BX100821
Plug type: One DB37 pin-type plug and four RJ45 plugs.
Cable form: Two connector electric cable, four with one.
Cable wire: 120 Ohm twisted-pair (each is 20CM long)
Table of outgoing lines:
MCUS DB37-RJ45 Outgoing lines:
RJ45 1 port RJ45 2 ports RJ45 3 ports RJ45 4 ports
Plug Pin Line
type No. color Outlet RJ45 Outlet RJ45 Outlet RJ45 Outlet RJ45
definition Pin No. definition Pin No. definition Pin No. definition Pin No.
4 LINE+0I 2

23 LINE-0I 1

24 LINE+0O 5

6 LINE-0O 4

8 LINE+1I 2

27 LINE-1I 1

28 LINE+1O 5

DB37 10 LINE-1O 4
Pin-
type
plug 12 LINE+2I 2

31 LINE-2I 1

32 LINE+2O 5

14 LINE-2O 4

16 LINE+3I 2

35 LINE-3I 1

36 LINE+3O 5

18 LINE-3O 4

46 , 40
MCUS DB37-BNC Cable
ID: DB37-8BNC
Cable form: one DB37-pin bonding wire plug and eight BNC connectors.
Cable form: two-connector cable, one with eight.
Cable line: 75 ohm coaxial line (standard)
Table of outgoing lines:
10MCUS DB37 table des lignes de dpart
channel 1 channel 2 channel 3 channel 4
input core 4 8 12 16
cloth 23 27 31 35
output core 24 28 32 36
cloth 6 10 14 18

3.2 2M ligne de dpart de E1PS

Cable EIPS DB62-BNC


Cable form: one DB62-pin prise de fil de liaison 16 connecteurs BNC
Forme du cble : deux cbles connecteurs, une avec seize.
Cable line: 75 ohm coaxial line (standard)
Table of outgoing lines:
EIPS DB62-BNC Cable
channel 1 channel 2 channel 3 channel 4
input core 43 1 24 47
cloth 44 2 25 48
output core 24 45 3 26
cloth 23 46 4 27

EIPS DB62-BNC Cable


channel 1 channel 2 channel 3 channel 4
input core 5 28 51 9
cloth 6 29 52 10
output core 49 7 30 53
cloth 50 8 31 54

EIPS DB62-RJ45 Cable


ID: DB62-8RJ45
No.:BX100823
Cable form: one DB62-pin bonding wire plug and eight RJ45 sockets.
Cable form: two-connector cable, one with eight.
Cable line: 120 ohm coaxial line
plug pin RJ45 socket(1port) RJ45 RJ45 RJ45
form no. socket2port socket3port socket4port
definition RJ45 definition RJ45 definition RJ45 definition RJ45
of socket of socket of socket of socket
BX10 Integrated Service Platform
outgoing pin outgoing pin outgoing pin outgoing pin
lines no. lines no. lines no. lines no.
DB62 43 LINE+0I 2
pin-type 44 LINE-0I 1
plug 22 LINE+0O 5
23 LINE-0O 4
1 LINE+1I 2
2 LINE-1I 1
45 LINE+1O 5
46 LINE-1O 4
24 LINE+2I 2
25 LINE-2I 1
3 LINE+2O 5
4 LINE-2O 4
47 LINE+3I 2
48 LINE-3I 1
26 LINE+3O 5
27 LINE-3O 4

plug pin RJ45 socket(5port) RJ45 RJ45 RJ45


form no. socket6port socket7port socket8port
definition RJ45 definition RJ45 definition RJ45 definition RJ45
of socket of socket of socket of socket
outgoing pin outgoing pin outgoing pin outgoing pin
lines no. lines no. lines no. lines no.
DB62 5 LINE+4I 2
pin-type 6 LINE-4I 1
plug 49 LINE+4O 5
50 LINE-4O 4
28 LINE+5I 2
29 LINE-5I 1
7 LINE+5O 5
8 LINE-6O 4
51 LINE+6I 2
52 LINE-6I 1
30 LINE+6O 5
31 LINE-6O 4
9 LINE+7I 2
10 LINE-7I 1
53 LINE+7O 5
54 LINE-7O 4

Definitions of signals of the DB62 hole-type plug


Pin No. 2M signal name Pin No. 2M signal name
43 R1+ 44 R1-
22 T1+ 23 T1-

48 , 40
BX10 Integrated Service Platform
1 R2+ 2 R2-
45 T2+ 46 T2-
24 R3+ 25 R3-
3 T3+ 4 T3-
47 R4+ 48 R4-
26 T4+ 27 T4-
5 R5+ 6 R5-
49 T5+ 50 T5-
28 R6+ 29 R6-
7 T6+ 8 T6-
51 R7+ 52 R7-
30 T7+ 31 T7-
9 R8+ 10 R8-
53 T8+ 54 T8-

3.3 VF Cable

ID: BX10-C-2/4W
No.: BX100803
Plug typeUn DB26 type de broches
Forme de cble: un connecteur de cble lectrique
Fil de cble: 16-noyaux audio coupls cble 8 2 0,4 (norme 5M)
Sortie des lignes:

Cble
Cble Cble
sortie de cble VF 2/4W tlphonique
Type de Pin automatique
porteur aimant
prise No. Couleur de Dfinition de Dfinition de Dfinition Dfinition
ligne prise prise de prise de prise
DB26 14 Bleu 1-2W/4WT
pin-type
bleu arrire-
plug plan
5 1-2W/4WT
et anneau
noir
15 Rouge 1-4WR 1A 1A

49 , 40
BX10 Integrated Service Platform
rouge
arrire-plan
6 1-4WR 1B 1B
et anneau
noir
17 Vert 2-2W/4WT
Vert arrire-
8 plan et 2-2W/4WT
anneau noir
18 Marron 2-4WR 2A 1A
Marron
arrire-plan
9 et anneau 2-4WR 2B 1B
noir
22 gris 3-2W/4WT
gris arrire-
21 plan et 3-2W/4WT
anneau noir
20 Jaune 3-4WR 3A 2A
Jaune
arrire-plan
19 et anneau 3-4WR 3B 2B
noir
11 Blanc 4-2W/4WT
Blanc
arrire-plan
2 4-2W/4WT
et anneau
noir
12 Pink Rose 4-4WR 4A 2A
Pink
arrire-plan
3 4-4WR 4B 2B
et anneau
noir

3.4 Cable VF E/M

ID: BX10-C-E/M
No.: BX100829
Plug typeOne DB26 pin-type plug
Cable form: One connector electric cable.
Cable wire: 32-core audio paired cable 162 0.4 (standard 5M)
Note: apply to versions after BX10-EMC V1.2
Outgoing cables:
Plug Pin Outgoing lines of EMC
Line color
type No. Outlet definition
DB26 14 fond noir et anneau bleu 1-E1

50 , 40
BX10 Integrated Service Platform
5 fond bleu et anneau noir 1-M1
15 fond marron et anneau rouge 1-E2
6 fond rouge et anneau brun 1-M2
17 black background and green ring 1-2W
8 green background and black ring 1-2W
white background and brown
18 1-4W
ring
brown background and white
9 1-4W
ring
22 white background and grey ring 2-E1
21 grey background and white ring 2-M1
pin-type
20 blue background and yellow ring 2-E2
plug
19 yellow background and blue ring 2-M2
orange background and white
11 2-2W
ring
white background and orange
2 2-2W
ring
12 white background and green ring 2-4W
3 green background and white ring 2-4W
16 black background and brown ring 1-SG
7 brown background and black ring 1-SB
10 blue background and white ring 2-SG
1 white background and blue ring 2-SB

ID: BX10-C-E/M
No.: BX10808
Plug typeOne DB26 pin-type plug
Cable form: one connector electric cable.
Cable wire: 32-core audio paired cable 162 0.4 (standard 5M)
Note: apply to BX10-EMC V1.1
Outgoing lines:
Plug Pin Outgoing lines of EMC
Line color
type No. Outlet definition
DB26 25 black background and blue ring 1-E1

51 , 40
BX10 Integrated Service Platform
26 blue background and black ring 1-M1
14 brown background and red ring 1-E2
5 red background and brown ring 1-M2
16 black background and green ring 1-2W
7 green background and black ring 1-2W
white background and brown
17 1-4W
ring
brown background and white
8 1-4W
ring
4 white background and grey ring 2-E1
13 grey background and white ring 2-M1
pin-type
22 blue background and yellow ring 2-E2
plug
21 yellow background and blue ring 2-M2
orange background and white
10 2-2W
ring
white background and orange
1 2-2W
ring
11 white background and green ring 2-4W
2 green background and white ring 2-4W
15 black background and brown ring 1-SG
6 brown background and black ring 1-SB
20 blue background and white ring 2-SG
19 white background and blue ring 2-SB

3.5 10BASE-T Cable

ID: BX10-10BASE-T
No.: BX100805
Plug typeOne DB26 pin-type plug and two RJ45 sockets
Cable form: two connector electric cable, 1 with 2.
Cable wire: 4-core shielded twisted pair (super CAT 5)
Outgoing lines:
Plug type Pin Outgoing 10BASE data cable (1 Outgoing 10BASE data cable (2
No. port) ports)

52 , 40
BX10 Integrated Service Platform
Outlet Outlet
RJ45 Pin No. RJ45 Pin No.
definition definition
white background
1 TD-2 and blue ring2
[Cable 2]
white background
2 RX-2 and orange
ring6[Cable 2]
3
4
5
white background
6 TD-1 and blue ring2
[Cable 1]
white background
7 RX-1 and orange
ring6[Cable 1]
8
9
DB26
10 TX+2 Blue 1[Cable 2]
pin-type Orange 3[Cable
11 RX+2
2]
12
13
14
15 TX+1 Blue 1[Cable 1]
Orange 3[Cable
16 RX+1
1]
17
18
19
20
21
22
23
24
25
26

53 , 40
BX10 Integrated Service Platform

3.6 RS232/485 Data Cable

ID: BX10-D-RS232/485cable length


No.: BX100806
Plug typeOne DB26 pin-type plug and four DB9 hole-type plugs.
Cable form: two connector electric cable, 1 with four.
Cable wire: 4-core VF cable
Outgoing lines:
Pin No.
RS232 RS485
of the
No. Outlet Outlet Cable 1 Cable 2 Cable 3 Cable 4
DB26
definition definition
plug
1 8 RX1 RX1+ White
2 17 RX1- Red
3 14 TX1 TX1+ Green
4 5 TX1- Brown
5 15 RX2 RX2+ White
6 6 RX2- Red
7 16 TX2 TX2+ Green
8 7 TX2- Brown
9 3 RX3 RX3+ White
10 12 RX3- Red
11 20 TX3 TX3+ Green
12 19 TX3- Brown
13 10 RX4 RX4+ White
14 1 RX4- Red
15 11 TX4 TX4+ Green
16 2 TX4- Brown
17 25 GND GND Black Black
18 26 GND GND Black Black

54 , 40
BX10 Integrated Service Platform
3.7 V35 Data Cable

ID: BX10-D-V35cable length


No.: BX100804
Plug type: One DB26 pin-type plug and four M34 hole-type plugs.
Cable form: two-connector electric cable, 1 with two.
Cable wire: 16-core audio paired cable 82 0.4
Outgoing lines:
Outgoing V.35 data cable (1 port) Outgoing V.35 data cable (2 ports)
Plug Pin
Outlet M34 hole-type Outlet M34 hole-type
type No.
definition plugPin No. definition plugPin No.
DB26 brown background and
pin-type 1 RC-2 black ring X[Cable
plug 2]
2 RD+2 Green R[Cable 2]
3 TD+2 Blue P[Cable 2]
grey background and
4 TXC-2 black ring W[Cable
2]
red background and
5 TC-1 black ring AA
[Cable 1]
brown background and
6 RC-1 black ring X [Cable
1]
7 RD+1 Green R[Cable 1]
8 TD+1 Blue P[Cable 1]
grey background and
9 XTC-1 black ring W[Cable
1]
10 RC+2 Brown V[Cable 2]
11 RD-2 green background and
black ring T[Cable
2]

55 , 40
BX10 Integrated Service Platform
blue background and
12 TD-2 black ring S[Cable
2]
13 XTC+2 Grey U[Cable 2]
14 TC+1 Red Y[Cable 1]
15 RC+1 Brown V[Cable 1]
green background and
16 RD-1 black ring T[Cable
1]
blue background and
17 TD-1 black ring S[Cable
1]
18 XTC+1 Grey U[Cable 1]
red background and
19 TC-2 black ring AA
[Cable 2]
20 TC+2 Red Y[Cable 2]
yellow background and
21 PGND
black ring (A) [Cable 1]
22
23
yellow background and
24 PGND
black ring (A) [Cable 1]
25 GND Yellow B[Cable 1]
26 GND Yellow B[Cable 2]
Notice: in M34 plug, C (RTS) and D (CTS) are in short-circuit, and E (DSR), F
(DCD) and H (DTR) are in short-circuit.

3.8 V35 and 10BASET Data Cable

ID: BX10-D-V3510BASETcable length


No.: BX100807
Plug type: One DB26 pin-type plug, one M34 hole-type plug and one RJ45
socket.
Cable form: two-connector electric cable, 1 with two.
Cable wire: 16-core audio paired cable [V35] 8X2X0.4 and 4-core shielded
twisted pair (super CAT) [10BASET]

56 , 40
BX10 Integrated Service Platform
Outgoing lines:
Outgoing 10BASE data cable (2
Outgoing V.35 data cable (1 port)
Plug Pin ports)
type No. Outlet M34 hole-type Outlet
RJ45 Pin No.
definition plugPin No. definition
DB26 white background and
pin-type 1 TD-2 blue ring2[Cable
plug 2]
white background and
2 RX-2 orange ring6
[Cable 2]
3
4
red background and
5 TC-1 black ring AA
[Cable 1]
brown background and
6 RC-1 black ring X[Cable
1]
7 RD+1 Green R[Cable 1]
8 TD+1 Blue P[Cable 1]
grey background and
9 XTC-1 black ring W[Cable
1]
10 TX+2 Blue 1[Cable 2]
Orange 3[Cable
11 RX+2
2]
12
13
14 TC+1 Red Y[Cable 1]
15 RC+1 Brown V[Cable 1]
green background and
16 RD-1 black ring T[Cable
1]
17 TD-1 blue background and
black ring S[Cable
1]

57 , 40
BX10 Integrated Service Platform
18 XTC+1 Grey U[Cable 1]
19
20
21
22
23
yellow background and
24 PGND
black ring (A) [Cable 1]
25 GND Yellow B[Cable 1]
26
Notice: in M34 plug, C (RTS) and D (CTS) are in short-circuit, and E (DSR) and
F (DCD) and H (DTR) are in short-circuit.

3.9 RS232/485 Monitoring Cable

RS232 monitoring cable


DB9 hole-type
RJ45 plug Pin No. Signal definition Line color
plug
1
2 TX 2 Blue
3 RX 3 Orange
4
5 GND 5 Green
6
7
8

RS485 monitoring cable


RJ45 plug pin DB9 pin-type
Signal definition Line color
number plug
1
2
3
4 TX+ 2 Blue
5 GND
white background
6 TX- 1
and blue ring
white background
7 RX- 3
and orange ring

58 , 40
BX10 Integrated Service Platform
8 RX+ 4 Orange

3.10 -48 Power Cable

DB3 pin-type Backboard


Signal Definition Line color
plug Indication
A1 Negative - Red
A2 Protective ground P.G. Yellow
A3 Positive + Black

59 , 40