Calculation
Valve Design Criteria

Outlet velocity for liquid w < 3 m/s


for gas and water steam w < 0,3 Mach
without sound pressure level requirement w < 0,6 Mach

p at the valve must exceed the total deviation Xw

Max. viscosity approx 100 c P

Upwards mounting of the regulator by minus temperature

Stellited trim for cavitation when p > 15 bar

Not suitable for combustible gases, H2, seawater, HCl and foamy liquid

Paint compatible version for the automobile industry

Two step pressure reducing when p valve > max. permissible p

Vacuum regulation with differential pressure regulator

1
2/24/2017

APPLICATION

Example for Industry Application and Supply System

General supply systems, steam pressure reduction of a manifold etc.


Air and ventilation systems, pressure reduction downstream of a compressor
Chemical and petrol industry, tank blanketing (inert gases)
Chemical and petrol industry and others, emergency air supply system
Automobile industry, body silicon, oil and grease free
Off-shore, sea air resistant design (not resistant to sea water)
Casting, blow in from oxygen (body stainless steel, oil and grease free)
Paper industry, guide cap and stem fixed
Tobacco industry, PTFE free

APPLICATION

Legend for Application examples

1), 3) and 4) Pressure Reducing Valve

2) Excess Pressure Valve

8) Steam Trap

9) Strainer

10) Temperature Regulator

2
2/24/2017

APPLICATION

Pressure reduction in a pipeline

APPLICATION

Excess pressure in a pipeline

3
2/24/2017

APPLICATION

Steam pressure reduction upstream of a manifold

APPLICATION

Pressure control in a steam-heated degasifying plant

4
2/24/2017

APPLICATION

Pressure reduction downstream of a compressor

5
2/24/2017

6
2/24/2017

7
2/24/2017

8
2/24/2017

APPLICATION

Tank blanketing
Important in chemical and petrol industry

Application: Tank blanketing means: Toxic liquids blanketed with inert gases N 2,
CO2 and other (You need type 41-23 and 41-73 set point between 5-50mbar
body mainly in stainless steel or GS-C 25, A 216 WCB with soft sealing)

9
2/24/2017

APPLICATION

Emergency supply system