3 AT Roof lvl

Only critical slabs are designed


S.no Flooring(mm) Live Load(KN/sqm) Filling
KN/m^2 mm KN/m^2 mm restrained type Ly/Lx = beta x= gamma= beta1= beta2= Nos. of disc. Edge =
s1 24 0 23 18 0 0 4 2.11 0.072 0.458686 0.000 0.045 2

LEGEND END CONDITIONS


w = Factored Uniformly distributed loading on slab in KN/m for per m width 1 Interior panel
E.C. = End condition as per the Table 2 One short edge discontinuous
Ly = Longer Span of the slab in meters 3 One long edge discontinuous
Lx = Shorter Span of the slab in meters 4 Two adjacent edges discontinuous
D = Over all depth of slab 5 Two short edges discontinuous
d = Effective depth of slab 6 Two long edges discontinuous
Ast = Area of reinforcement in square cm. 7 One long edge continuous
Mom. = Factored Moment on slab in KN-m for per m width 8 One short edge continuous
9 Four edges discontinuous

shorter span longer span shorter span longer span shorter span longer span
slab w E.C. clear Ly Lx D d Fc Fy supp span supp span supp span supp span supp span supp span
no cover coeff Mom. coeff Mom. coeff Mom. coeff Mom. Ast(cm^2) Ast(cm^2) Ast(cm^2) Ast(cm^2) R/F req. R/F req. R/F req. R/F req.
s1 40.13 4 25 4.90 2.32 150 110 25 500 0.096 20.74 0.072 15.55 0.045 9.72 0.034 7.34 4.75 3.47 2.11 1.80 10 @ 165 c/c 10 @ 225 c/c 8@ 235 c/c 8@ 275 c/c

Check for Deflection


shorter span longer span shorter span fs Multiplication Edge (a * b) d reqd. Overall Overall Check
slab supp span supp span Bott. R/F prov Factor Condition Depth REQ. Depth PROV
no R/F prov. R/F prov. R/F prov. R/F prov. Ast(cm^2) (a) Value (b) D req. D prov.
s1 10 @ 150 10 @ 150 8@ 150 8@ 150 5.23 263.38 1.15 26 29.9 77.59 107.59 150.00 O.K.
Only critical slabs are designed
S.no Flooring(mm) Live Load(KN/sqm) Filling
KN/m^2 mm KN/m^2 mm restrained type Ly/Lx = beta x= gamma= beta1= beta2= Nos. of disc. Edge =
s1 24 0 2 18 0 0 4 1.40 0.055 0.353209 0.000 0.045 2
s2 24 50 3 18 0 0 4 1.42 0.056 0.357624 0.000 0.045 2
s3 24 50 2 18 0 0 4 1.96 0.069 0.442769 0.000 0.045 2

LEGEND END CONDITIONS


w = Factored Uniformly distributed loading on slab in KN/m for per m width 1 Interior panel
E.C. = End condition as per the Table 2 One short edge discontinuous
Ly = Longer Span of the slab in meters 3 One long edge discontinuous
Lx = Shorter Span of the slab in meters 4 Two adjacent edges discontinuous
D = Over all depth of slab 5 Two short edges discontinuous
d = Effective depth of slab 6 Two long edges discontinuous
Ast = Area of reinforcement in square cm. 7 One long edge continuous
Mom. = Factored Moment on slab in KN-m for per m width 8 One short edge continuous
9 Four edges discontinuous

shorter span longer span shorter span longer span shorter span longer span
slab w E.C. clear Ly Lx D d Fc Fy supp span supp span supp span supp span supp span supp span
no cover coeff Mom. coeff Mom. coeff Mom. coeff Mom. Ast(cm^2) Ast(cm^2) Ast(cm^2) Ast(cm^2) R/F req. R/F req. R/F req. R/F req.
s1 #ADDIN? 4 25 7.00 5.00 125 88 25 500 0.073 #ADDIN? 0.055 ### 0.045 #ADDIN? 0.034 ### #ADDIN? #ADDIN? #ADDIN? #ADDIN? 10 @ ### 8@ ### 8@ ### 8@ ###
s2 11.93 4 25 5.03 3.55 150 121 25 500 0.075 11.28 0.056 8.42 0.045 6.77 0.034 5.11 2.22 1.80 1.80 1.80 8@ 225 c/c 8@ 275 c/c 8@ 275 c/c 8@ 275 c/c
s3 9.49 4 25 5.03 2.56 125 96 25 500 0.092 5.72 0.069 4.29 0.045 2.80 0.034 2.11 1.50 1.50 1.50 1.50 8@ 285 c/c 8@ 285 c/c 8@ 285 c/c 8@ 285 c/c

Check for Deflection


shorter span longer span shorter span fs Multiplication Edge (a * b) d reqd. Overall Overall Check
slab supp span supp span Bott. R/F prov Factor Condition Depth REQ. Depth PROV
no R/F prov. R/F prov. R/F prov. R/F prov. Ast(cm^2) (a) Value (b) D req. D prov.
s1 10 @ 150 10 @ 150 8@ 200 8@ 200 5.23 ### #ADDIN? 26 ### #ADDIN? #ADDIN? 125.00 ###
s2 8 @ 150 8@ 150 8@ 200 8@ 200 3.35 192.18 2.00 26 52 68.27 97.27 150.00 O.K.
s3 8 @ 150 8@ 150 8@ 150 8@ 150 3.35 129.85 2.00 26 52 49.23 78.23 125.00 O.K.