You are on page 1of 4

PRODUCT DATA SHEET

Sika Permacor-2706 EG
EP-mio-coating

PRODUCT DESCRIPTION Sika Permacor-2706 EG is a 2-pack mio-protective coating based on epoxy


resin with high mechanical resistance and outstanding adhesion.
Tested and official approved primer for Sika Unitherm fire protection
systems on steel.

USES Sika Permacor-2706 EG is used as primer for galvanized steel and also as
primer under Sika Unitherm fire protection systems, as well as intermediate
coating for atmospheric corrosion protection on steel.

PROPERTIES - Coating with high mechanical resistance


- For primed steel, directly on galvanized steel, sprayed zinc, stainless steel
and aluminium
- High content of mio offers dense and highly resistant layers

PRODUCT DATA
COLOUR SHADES Approx. RAL 7032, pebble grey
FINISH Mat
PACKAGING Sika Permacor-2706 EG: 24 kg and 3 kg net.
Sika Thinner E + B: 5 and 25 litres
SikaCor Cleaner: 25 and 160 litres
SHELF LIFE In originally sealed containers in a cool and dry environment 2 years.

SYSTEMS
COATING SYSTEMS Steel:
Possible primers:
Sika Permacor-2004, Sika Permacor-2029, Sika Permacor-2305 Rapid,
Sika Permacor-2311 Rapid, Sika Permacor-2204 VHS
Galvanized steel, sprayed zinc, stainless steel, aluminium:
1 x Sika Permacor-2706 EG
Possible topcoats:
Sika Permacor-2230 VHS, Sika Permacor-2330, Sika Permacor-2706,
Sika Permacor-2707 and Sika Unitherm or Sika Pyroplast Systems for
steel.

Product Data Sheet English


Sika Permacor-2706 EG Corrosion Protection
22.01.2014, Revision_01
DS-Code: 9023

1/4
SURFACE PREPARATION Steel:
Blast-cleaning to Sa 2 according to EN ISO 12944, part 4.
Free from dirt, oil and grease.
Galvanized steel:
Free of oil, grease and zinc salts.
In case of permanent exposure to submersion and condensation surfaces
should be sweep blasted according to EN ISO 12944 part 4.
Stainless steel, aluminium:
Sweep-blasting according to EN ISO12944, part 4 with non-metallic/
non-ferrous abrasives.
For contaminated and weathered surfaces e.g. galvanized or primed areas
we recommend to clean with SikaCor Wash.

TECHNICAL DATA
MATERIAL CONSUMPTION
Product Specific Solids content Theoretical material-consumption/
gravity approx. % coverage without loss for medium dry
liquid film thickness of

approx. by by dry wet approx. approx.


kg/L vol. weight microns microns kg/m m/kg
Sika Permacor-
1.4 45 66 40 90 0.125 8.03
2706 EG

MIXING RATIO
(COMPONENTS A : B)
By weight 100 : 20
RESISTANCE CHEMICAL RESISTANCE
Upon request
TEMPERATURE RESISTANCE
Dry heat up to approx. + 120C, short term up to + 150C

HINTS OF APPLICATION
MIXING INSTRUCTIONS/ Stir component A very thoroughly using an electric mixer (start slowly, then
MIXING TIME increase up to approx. 300 rpm). Add component B carefully and mix both
components very thoroughly (including sides and bottom of the container).
Mix for at least 3 minutes until a homogeneous mixture is achieved.
Fill mixed material into clean container and mix again shortly as described
above. During mixing and handling of the materials always wear protective
goggles, suitable gloves and other protective clothings.
APPLICATION METHOD The method of application has a major effect on achieving uniform thickness
and appearance. Spray application will give the best results. The indicated
dry film thickness is easily achieved by airless spray and by brush.
Adding solvents reduces the sag resistance and the dry film thickness.
In case of application by roller or brush, additional applications may become
necessary to achieve the required coating thickness, depending on type of
construction, site conditions, colour shade etc. Prior to major coating
operations a test application on site may be useful to ensure the selected
application method will provide the requested results.
By brush or roller
Airless spraying:
nozzle size: 0.38 mm

Product Data Sheet English


Sika Permacor-2706 EG Corrosion Protection
22.01.2014, Revision_01
DS-Code: 9023

2/4
APPLICATION CONDITIONS Min. + 10 C (material and surface)
Relative humidity: Max. 85 %, except the surface temperature is significantly
higher than the dew point temperature, it shall be at least 3 K above dew
point.
If necessary max. 2% Sika Thinner E + B may be added to adapt the viscosity.
POTLIFE At + 20C: Approx. 8 hours
DRYING TIME
Dry film thickness + 20C after
40 microns 16 h

WAITING TIME BETWEEN COATS Min: At 20C after 8 h


Max: Upon request
FINAL DRYING TIME Depending on film thickness and temperature full hardness is achieved
within 1 week at +20C. Tests of the completed coating system should only
be carried out after final curing.
THINNER Sika Thinner E + B
CLEANING OF EQUIPMENT SikaCor Cleaner

IMPORTANT NOTICE
DIRECTIVE 2004/42/EC For product category IIA / j, Type Sb, the maximum permissible content of
(DECOPAINT) VOC as per directive 2004/42/EC is 500 g/litre (limit 2010).
The maximum content of Sika Permacor 2706 EG remains below 500 g/litre
VOC.
VALUE BASE All technical data stated in this Product Data Sheet are based on laboratory
tests. Actual measured data may vary due to circumstances beyond our
control.
LOCAL RESTRICTIONS Please note that as a result of specific local regulations the performance of
this product may vary from country to country. Please consult the local
Product Data Sheet for the exact description of the application fields.
HEALTH AND SAFETY GISCODE: RE 3
INFORMATION This coding enables additional information and help with the creation of
operating instructions (WINGIS online) to be obtained on the BG Bau service
pages (www.gisbau.de).
Skin contact with epoxy resins can lead to allergies!
Avoid direct skin contact at all costs when handling epoxy resins!
For the selection of suitable protective equipment, we have made our
information data sheets 7510 General notes on occupational safety and
7511 General notes for wearing protective gloves available at www.sika.de.
In conjunction with this we also recommend the BG Bau service pages for
information regarding the handling of epoxy resins
(www.gisbau.de/service/epoxi/epoxi.htm).
Information on the safe handling of chemical products, as well as the essen-
tial physical, safety-related, toxicological and ecological data can be found in
the current safety data sheets. Observe all relevant regulations, e.g. the
hazardous substances act. Further notes and information data sheets on
product safety and disposal can be found on the Internet at www.sika.de.

Product Data Sheet English


Sika Permacor-2706 EG Corrosion Protection
22.01.2014, Revision_01
DS-Code: 9023

3/4
LEGAL NOTES The information, and, in particular, the recommendations relating to the application and end-
use of Sika products, are given in good faith based on Sikas current knowledge and experience
of the products when properly stored, handled and applied under normal conditions in accord-
ance with Sikas recommendations. In practice, the differences in materials, substrates and
actual site conditions are such that no warranty in respect of merchantability or of fitness for a
particular purpose, nor any liability arising out of any legal relationship whatsoever, can be
inferred either from this information, or from any written recommendations, or from any other
advice offered. The user of the product must test the products suitability for the intended
application and purpose. Sika reserves the right to change the properties of its products.
The proprietary rights of third parties must be observed. All orders are accepted subject to our
current terms of sale and delivery. The most recent product data sheet applies. This can be
requested from us or is available to download at www.sika.de. Please check availability of local
product data sheet at your local website. In cases of doubt the German text is valid.

2014 Sika Deutschland GmbH

Sika Deutschland GmbH Version given by


Industrial Coatings Industrial Coatings
Rieter Tal Phone: (07042) 109-0
71665 Vaihingen / Enz Fax: (07042) 109-180
Germany Mail: industrial-coatings@de.sika.com
www.sika.de

Product Data Sheet English


Sika Permacor-2706 EG Corrosion Protection
22.01.2014, Revision_01
DS-Code: 9023

4/4

You might also like