Heavy Fuel Oil supply units


Heavy Fuel Oil supply units

AMB-Mc Marine Compact Heavy Fuel Oil supply unit

This series of marine AMB-Mc Heavy Fuel Oil (HFO) supply units is developed The main features of the AMB-Mc units are The Marine Compact
maximal reliability and safety due to shell and tube type heaters and
to combine the proven accessibility and easy service. Compact outfit meets the series is available
separate controllers for viscosity and temperature
increasing demands of minimal spaces required for anything other than passenger a long lifespan and flawless operation due to the best available
in ten different size
or cargo purposes. components, carefully chosen materials and a sophisticated manufacturing classes according
system to the total engine
fast and simple installation due to its compact design and versatile pipe power to be served.
connections
easy operation with all the important operational parameters visible at a
AMB-Mc-18-SS glance due to separate displays and instruments
easily accessible service items; maintenance space only required in front
of and to the right end of the unit

The Marine Compact series is available in ten different size classes according
to the total engine power to be served.
In the nomenclature, the number refers to the engine power in MW and the
following letters represent the heater types:

steam heaters
thermal oil heaters
electric heaters
AMB-Mc-nn-SS/TT/EE
02, 03, 05, 07, 12, 15, 18, 26, 36, 50

The general arrangement drawings illustrate the space requirement and


locations of the connections. Adjacent to the flow sheet the functions of the
major components as well as options available for the AMB-Mc series are
described.
To ensure that the AMB-Mc units fit perfectly together with different fuel
types and engine configurations that call for various injection viscosities,
flow rates and pressures, each unit is offered independently with detailed
specifications.

Certified quality
The high quality of Auramarine operations is
guaranteed by ISO 9001, ISO 14001 and ISO
3834-2 certificates.
Heavy Fuel Oil supply units

AMB-Mc-0207 SS (TT) AMB-Mc-1226 SS (TT)

A DN40 HFO INLET H DN32 F.O. RETURN FROM ENGINE A DN50 HFO INLET H DN50 F.O. RETURN FROM ENGINE
B DN32 FUEL OIL TO ENGINE K DN20 STEAM INLET B DN50 FUEL OIL TO ENGINE K DN32 STEAM INLET
C R2 DRAIN FROM UNIT L DN20 CONDENSATE OUTLET C R2 DRAIN FROM UNIT L DN32 CONDENSATE OUTLET
D DN20 DEAERATION LINE P DN32 SLUDGE FROM AUTOM. FILTER D DN25 DEAERATION LINE P DN20 SLUDGE FROM AUTOM. FILTER
F DN40 MDO INLET F DN50 MDO INLET

AMB-Mc-02...07 AMB-Mc-12...26
Pump capacities (50/60 Hz) Pump capacities (50/60 Hz)
02 03 05 07 12 15 18 26
50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
Feeder pump 1,57 1,92 1,57 1,92 2,2 2,7 3,35 2,7 Feeder pump 3,35 4,64 4,71 5,75 6,39 7,78 6,39 7,78
[m3/h], 0/4 bar, 75 cSt [m3/h], 0/4 bar, 75 cSt 6,39 5,75
Booster pump 1,44 1,79 2,00 2,50 3,13 3,87 4,37 5,42 Booster pump 7,54 7,44 8,34 9,31 12,80 12,70 17,10 15,70
[m3/h], 4/8 bar, 20 cSt [m3/h], 4/8 bar, 20 cSt 10,30 10,40

This information is subject to change without prior notice. This information is subject to change without prior notice.
AMB-Mc-3660 SS (TT) Main components and options
MDO HFO
Daytank Daytank
Engines

AMB-Mc unit
B006
B010
B002 D001 B015 D003

Q001
B016

V001
B003 D002 B014 D004 B011

V010

D005/D006

ITEM COMPONENT OPTIONS


V001 HFO/MDO 3-way changeover valve for selecting fuel and flushing the system None
Manual
Remote-controlled
Smooth changeover valve, especially
for MGO use
B002 Suction strainers for protecting the pumps
B003
D001 Feeder pumps for pressurising the system with fresh fuel according to the con- Magnetic couplings
D002 sumption of the engines, equipped with an automatic stand-by function Mechanical couplings
Note:
all dimensions V010 Pressure control valve for maintaining constant system pressure at different Without bypass
for 36...50 loads With bypass
B014 Automatic filter with bypass filter for removing impurities from fuel oil and 34 / 25* / 10* m in cold side
B015 indication of failures in purification system, equipped with automatic cleaning 48 / 34 / 25* m in hot side
and pressure difference indication * certain fuel types and flows call for a larger frame
A DN65 HFO INLET H DN65 F.O. RETURN FROM ENGINE
B DN65 FUEL OIL TO ENGINE K DN40 STEAM INLET Q001 Flow meter for indicating fuel consumption None
C R2 DRAIN FROM UNIT L DN40 CONDENSATE OUTLET With local totalizer and output signal
D DN25 DEAERATION LINE P DN50 SLUDGE FROM AUTOM. FILTER B006 Mixing tank for mixing the return fuel from the engines with fresh fuel and for Manual deaeration
F DN65 MDO INLET compensating for temperature and pressure changes Automatic deaeration
D003 Booster pumps for further pressurising and circulating fuel to the engines, Magnetic couplings
D004 equipped with an automatic stand-by function Mechanical couplings
B010 Fuel heaters for heating the fuel oil to injection viscosity, controlled via visco Steam heating (SS)
B011 meter Thermal oil heating (TT)
AMB-Mc-36...60 Electric heating (EE)
Pump capacities (50/60 Hz) B016 Viscosity control system for measuring the fuel viscosity and controlling the Controller and display located
36 50 55 60 power of the heaters to maintain constant injection viscosity, secured by a in the AMB unit
50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz temperature controller Controller loose delivery for
Feeder pump 8,03 9,79 13,50 9,79 21,00 20,80 26,60 25,50 remote operation
[m3/h], 0/4 bar, 75 cSt D005/ One or two MDO/MGO pumps for a separate MDO supply for auxiliary engines None
Booster pump 19,92 20,10 25,50 24,60 40,70 38,00 49,90 49,80 D006 while running the main engines with HFO Screw type with electric motor
[m3/h], 4/8 bar, 20 cSt Screw type with air motor

This information is subject to change without prior notice.


Heavy Fuel Oil supply units

Control panel and electrical connections Auramarine service, spare parts and training
D01 D03 D02 D04
Cables installed to the unit Close to you all over the world
ST-BY

ST-BY

ST-BY

ST-BY
RUN

RUN

RUN

RUN
REMOTE REMOTE REMOTE REMOTE
CONTROL CONTROL CONTROL CONTROL
1 0 2 1 0 2 1 0 2 1 0 2 Cables to be connected by shipyard Auramarine has two extensive spare part
facilities: one in Europe and the other in Asia.
In addition to that, we have representatives in
1

3
30 other countries, so customer support and
service is always nearby.
OPTIONAL
D01
D01 D03
D03 D01 D03 D02
D02 D04
D04 D02 D04 Cables installed to the unitinstalled to the unit
Cables
ST-BY

ST-BY

ST-BY

ST-BY
ST-BY

ST-BY

ST-BY

ST-BY
RUN

RUN

RUN

RUN
REMOTE
REMOTE REMOTE
REMOTEREMOTE REMOTEREMOTE
REMOTE REMOTE
REMOTEREMOTE
RUN

RUN

RUN

RUN
REMOTE
CONTROL
CONTROL CONTROL
CONTROLCONTROL CONTROLCONTROL
CONTROL CONTROL
CONTROLCONTROL CONTROL V01

MDO
EMERGENCY EMERGENCY REMOTE

HFO
11 00 22 11 00 22 1 0 2
STOP 1 0 2 11 00 22 11 00 22 1 0 2
STOP 1 0 2 Cables to be connected by to
Cables shipyard
be connected by shipyard CONTROL
SUPPLY

SUPPLY

SUPPLY
0 1
1

3
1

2
1
2

1
2
OPTIONAL
OPTIONAL OPTIONAL

V01
V01 V01

MDO
EMERGENCY
EMERGENCY EMERGENCY
EMERGENCY REMOTE
REMOTE

HFO

MDO
EMERGENCY EMERGENCY REMOTE

HFO
STOP
STOP STOP STOP
STOP STOP CONTROL
CONTROL CONTROL
SUPPLY

SUPPLY

SUPPLY
00 11
SUPPLY

SUPPLY

SUPPLY
0 1

Original Auramarine spare parts

2
1
2

1
2

2
1
2

1
2
Auramarines fuel supply systems are durable and the supply of spare parts is
secured for all models.
A standard spare part is shipped within 24 hours of ordering and reaches
its destination in 23 days. If necessary, we can also send a mechanic to carry
out maintenance duties anywhere in the world at very short notice.

Proactive maintenance
Auramarine offers its customers spare part packages for proactive mainte-
nance. For example, all spare parts and packings required in annual mainte-
nance are delivered to you.
TO BOOSTER
INSTRUMENT
TO CONTROL PANEL

TO CONTROL PANEL

TO STARTERS
2
1
2
3

1
2
3

1
2
3

1
2
3

1
2
3

M M M M M M
3~ 3~ 3~ 3~ 3~ 1~ Yearly maintenance package
FEEDER- BOOSTER- FEEDER- BOOSTER- AUTOFILTER STEAM
PUMP D01 PUMP D03 PUMP D02 PUMP D04 B14 VALVE V86 We offer packages that may be used to replace wear parts at regular intervals
and on time, which secures the functionality and the original condition of the
system year after year. Annual packages and biennial packages are available.
TO BOOSTER
INSTRUMENT
TO CONTROL PANEL

TO CONTROL PANEL

TO STARTERS
TO BOOSTER
INSTRUMENT
TO CONTROL PANEL

TO CONTROL PANEL

TO STARTERS
2
1
2
3

1
2
3

1
2
3

1
2
3

1
2
3

2
1
2
3

1
2
3

1
2
3

1
2
3

1
2
3

M
M M
M M
M M
M M
M M
M
33 ~~ 33 ~~
M
3~
M
3~ 33 ~~ 33 ~~
M
3~
M
3~ 33 ~~ 11 ~~
M
3~
M
1~ Modernization package
FEEDER-
FEEDER- BOOSTER-
BOOSTER- FEEDER-
FEEDER- BOOSTER-
BOOSTER- AUTOFILTER
AUTOFILTER STEAM
STEAM
PUMP
PUMP D01
D01 PUMP
PUMP D03
D03
FEEDER-
PUMP D01
BOOSTER-
PUMP D03 PUMP
PUMP D02
D02 PUMP
PUMP D04
D04
FEEDER-
PUMP D02
BOOSTER-
PUMP D04 B14
B14 VALVE
VALVE V86
V86
AUTOFILTER
B14
STEAM
VALVE V86 Auramarines fuel supply units are renowned for their durability and long life.
You may order either separate spare parts or use the upgrade packages, which
upgrade the features of the old machinery to the level of the new, more devel-
oped systems. The upgrading packages may be used to increase, for example,
OPTIONAL SIGNALS/FEATURES the reliability, fuel economy and environmental friendliness. 24/7
Viscosity signal to engine control room E.C.R. (mA) In case of emergency, call our Emergency
service number. It is open 24 h a day. Dial
Viscosity controller delivered loose for installation to E.C.R. Separate spare parts +358 20 486 6003.
Change-over valve position indication and control You may also order separate spare parts with the spare part order form. We
Fuel consumption signal to E.C.R. (mA or pulse) guarantee that the delivered parts are original Auramarine spare parts. They
Control of MDO/MGO pumps are guaranteed to fit your equipment and perform as required.
Temperature signal to E.C.R. (mA or PT-100) Service center contact:
Auramarine Ltd
Two alarm groups Training P.O. Box 849
Additional displays to E.C.R. Auramarine service trainings make sure that the personnel in the engine room FI-20101 Turku, Finland
Tel. +358 204 86 5030
Frequency converter driven pumps are familiar with the equipment features, uses them correctly and that the Fax +358 204 86 5031
Programmable logic control Frequency converter for pumps Programmable logic control proactive maintenance is carried out at the right time. after.sales@auramarine.com

This information is subject to change without prior notice.


Auramarine Number one expertise on the seven seas.
Auramarine has been the worlds leading manufacturer
of fuel oil supply systems for over 30 years. We have wide-
ranging experience in liquid flows and this craftmanship
is also utilized in design and manufacture of cooling water
and lubrication oil units. With over 10,000 skid mounted
auxiliary units, Auramarine has superior experience in

96758 / 15.11.
fuel systems. Our solutions include planning, required
technical equipment alteration work and 24/7 spare
parts service.

Auramarine HFO (Heavy Fuel Oil supply units)


HFO unit series with easy accessibility and service meets the increasing demand to minimize the
required space for any other purposes than passenger or cargo.

Auramarine MGO (Marine Gas Oil handling unit)


Auramarine offers fast and reliable solutions when the switch to low sulphur fuel is needed.
The unit works seamlessly with the AMB and all other HFO units.

Auramarine After Sales


Auramarines primary task is to ensure the continuous and faultless operation of your ships.
This is why our After Sales service is available 24/7. Moreover, we have a global dealer and agent
network. Under normal conditions the required help or spare part is dispatched to the ship within
24 hours and delivered in 2 to 3 days.

AURAMARINE LTD
P.O. Box 849
FI-20101 Turku
FINLAND
Tel. +358 204 86 5030
sales@auramarine.com
www.auramarine.com

You might also like