Multi Series

Inverter Multi-Split System Air Conditioners MHIAA is proudly sponsoring


Monikas Doggie Rescue
2 Multi Series
Inverter Multi-Split System Air Conditioners.

The ideal solution for air


conditioning multiple rooms
MULTI series Air Conditioners 2013
WELCOME
A home typically has many areas such as bedrooms, living
spaces and study rooms. Therefore, to provide total comfort
for your home, a multi-split system is recommended so each
room can have its own air conditioner.

This can be achieved through a Mitsubishi Heavy Industries


inverter multi-split system which delivers optimum
heating or cooling for everyone, no matter where they are
in the home and no matter what size the room may be.
Silent, powerful, energy efficient and utilising advanced
technologies, a Mitsubishi Heavy Industries inverter multi-
split system is the solution for homes with many rooms and
occupants.

3
4

Compact
A Mitsubishi Heavy Industries inverter multi-split system allows 2 to 6 indoor units to be connected to a single
outdoor unit. This allows multiple rooms to be conditioned without adding clutter to the exterior of your home.
One compact multi-split outdoor unit instead of many outdoor units not only adds to the ascetic appeal your
home but can be imperative when there is not much space available, for example, when installing outdoor units
on balconies or verandahs.

Installation Flexibility
With a generous maximum piping length of 70m*, you are given greater freedom to decide where the indoor
units will be installed to optimise interior space and convenience. In addition, a maximum height difference of
25m* for the indoor units means the Mitsubishi Heavy Industries inverter multi-split system can easily service
the rooms for multi storey homes.

Variety of Indoor Units


The indoor unit range includes wall mounted, floor standing, low static bulkhead or compact cassette types in
a wide range of capacities. This makes hundreds of combinations possible for your home. You can choose the
right type of indoor unit to complement the interior dcor and match the size of each room.

*Please check model specifications as these pipe lengths and height differences do not apply to all models.

MULTI series Air Conditioners 2013


MULTI CONCEPT
Independent Control and Comfort
Each indoor unit comes with its own remote allowing the unit to be independently switched on/off and have the
temperature adjusted as needed. The conditions of rooms can vary greatly depending on many variables such
as the number of occupants or the way the room is used. With a range of comfort, air flow and convenience
functions on each indoor unit, you can adjust the settings to match the requirements of a room without
affecting other ones. When a room is unoccupied you can switch off the unit to reduce inefficient energy use.

5 Year Warranty
When you buy a Mitsubishi Heavy Industries inverter multi-split system, you are getting an air conditioning
solution from a company that some of the highest quality products in the industry. Mitsubishi Heavy Industries
enjoys a reputation for outstanding quality and is highly respected both in the Australian and overseas markets.
With our 5 Year Warranty covering the parts, labour and compressor, you can peace of mind that your new
Mitsubishi Heavy Industries inverter multi-split system will continue to deliver air-conditioning comfort to your
home through the years.

5
6

Easy operation
All settings done by tapping touch screen panel

Operation mode setting screen

Setting temperature screen

The operation mode can


be selected by simply tapping
this button.

You can select the desired


Operation mode temperature by tapping the
button.
Cooling Dry Auto Fan Heating

Main functions
Energy management
Peak cut timer Automatic temperature set back Weekly timer Set ON/OFF timer by hour
Set ON/OFF timer by clock Fan only operation Sleep timer

Comfort
Individual ap control High power operation External ventilation ON/OFF Warm up
operation Automatic fan speed Temperature increment setting by 0.5C

Convenience
LCD contrast setting Back light setting Filter clean sign Control sound Outdoor silent
mode Summer time setting Home leave mode Indoor & outdoor temperature display
Heating standby display Defrosting operation display Auto cooling/heating display C/F
display Administrator settings Room name setting

Service
Error code display Operation data display Next service data display Contact company
display USB connection (mini-B)

MULTI series Air Conditioners 2013


Functions.
Filter
Allergen Clear Filter Natural Enzyme Filter
Allergen The filter breaks down the pollen, lice, and all allergens that live on
Enzyme Enzymes used in the filter are naturally occurring lytic enzymes
Filter Filter which attack cell walls of microorganisms trapped on the filter

CONTROL & FUNCTIONS


cat skins, etc. and deactivates them.
and destroy them.
Photocatalytic Washable Deodorizing Filter
SUN See details on page 2.
It keeps air fresh by deodorizing the molecules causing odor. Allergen Self Clean
Filter The deodorizing ability can be easily restored simply by cleaning
System Operation
and exposing the filter to the sunlight.

Comfortable Functions
Fuzzy Auto Mode "HI POWER" Operation
Automatically the unit determines its operating mode and temperature The unit can operate continuously in HI POWER mode for 15 minutes.
setting based on a fuzzy calculation and adjusts the inverter frequency. This mode is used to reach the desired temperature quickly.

ar
t Sp Three "Hot" System
Automatic Operation

ur
St
3HOT Hot start enables the unit to begin heating operation quickly.

t
The air conditioner automatically selects from heating, cooling or Hot spurt is a fast heating system that works to increase the
Keep
dry operation. temperature setting by two degrees.
Hot keep is used during the automatic defrost cycle to prevent
cool air being circulated.
These three operational control systems help ensure comfortable
and efficient heating.

Comfortable Air Flow Functions


3D Auto Memory Memory Flap
You can choose the best heating or cooling pattern with the touch While the flap is swinging it can be stopped at any angle. The flap
Auto of a button. returns to this position next time the unit starts.

COOLING & DRY


UP/DOWN Up/Down Flap Swing SWING FLAP
Auto Flap Auto Flap Mode Horizontal blowing
The Up/Down flap can be adjusted Flap moves up and
The unit automatically down
to the preferred angle anywhere
selects the optimal angle
HEATING between horizontal and perpendicular. continuously.
whatever the operation
Slant forward
mode.
blowing Lateral Lateral Swing
The louver swings from right to left automatically. Louver angle
Swing can be fixed in any desired position.

COOLING & DRY Air outlet Air Outlet Selection


Air Scroll Air Scroll Thick line : moves quickly selection Both lower and upper air outlets and upper air outlet can be
The swing of the flap Thin line : moves slowly selected. (SRF models only)
causes the air flow to
spiral and the breeze HEATING
Thick line : moves quickly Positioning
Positioning of Installation
to reach all corners of
Thin line : moves slowly of You can set the left-right air flow directions when you install the air
the room.
installation conditioner near the side wall by remote controller operation.

Convenience & Economy Functions


On Timer On Timer 24-hour On/Off Programmable Timer
This enables the operation to start a little earlier so that the room is 24h Timer By combining a start timer with a stop timer you can register two
near to the set temperature at ON time. timer operations a day. Once set timers will start or stop the
system at the specified time of the day repeatedly.

Economy Economy Mode OFF Timer Off Timer


The unit achieves effective energy saving operation while still keeping The unit stops at the specified time.
a comfortable cooling or heating operation.

Dry Operation Sleep Sleep Mode


The unit dehumidifies the room by intermittent cooling operation. The room temperature is automatically controlled during the set
DRY sleep mode period ensuring that the room temperature will not
get too hot or cold.

Maintenance & Prevention Functions


Microcomputer-Operated Defrosting Detachable Detachable Indoor Air Inlet Panel
MC This function automatically eliminates frost and helps minimize The air inlet panel on the indoor unit opens and closes easily
excessive operation in other modes. making filter cleaning simple. The suction panel can be easily
removed.

Self Self-Diagnostic Function When removing the air inlet


Diagnostic If the air conditioner malfunctions an internal microcomputer runs a panel for internal cleaning or
self diagnosis. Inspection and repair should be performed by other reasons, open the grill
authorized dealers. by 65 degrees and then pull
it to the side.

Others
Back-up Back-up Switch 24-hour ION
Switch On the indoor unit there is a back up on/off switch. The system will 24h ION The air conditioner body has a tourmaline coated sheet. Negative
operate in the previous mode. ions (2,500 -3,000/cc) are generated when the air conditioner is not
running, allowing you to experience them without incurring any
electrical cost.
Auto Auto Restart Function Luminous Button
Restart Power blackout auto restart function records the operational status of Luminous
the air conditioner immediately prior to being switched off by a power With wireless Luminous remote controls that even glow in the
supply interruption. The unit automatically resumes operations in the dark, it is possible to operate all desired functions of the unit with
the click of a button.
mode and temperature set point after the power has been restored.

7
8 High Efficiency.
DC PAM inverter New inverter control
An inverter system has a number of advantages over a
constant speed system. Its variable speed compressor
(Vector control)
outputs can ensure quick cooling or heating after start New Inverter Control has applied the new advanced
up and attains a set temperature more quickly. The air technology of Vector control enabling:-
conditioner can slow down the compressor speed to Smooth operation from low to high speed
save energy whilst keeping comfortable conditions. The Smooth Sine Voltage Wave form is achieved
compressor is DC motor driven so it provides superior Energy efficiency has improved in low speed range
performance.
Time
DC compressor motor
Time
Room Temp. Room Temp.

DC
DC PAM CONVENTIONAL
Magnet Motor INVERTER INVERTER
PAM PWM
Motor Efficiency(%)

Set Temp. Set Temp.

PowerActiveModule Improving
Even Temperature

PAM Improving DC PAM


INVERTER
Rated Capacity CONVENTIONAL ON Rated Capacity

INVERTER
ON OFF OFF Compressor
Induction Motor Compressor
(rps) (rps)

Low Revolution speed High


Utmost comfort and energy efficiency achieved Less advanced technology does not address
with large output power and control optimisation the ON/OFF cycle issue.

Advanced Technology.

Silicon-coated PCB
The printed circuit board of the outdoor unit is
coated by silicon. The coating ensures longevity
of the board in humid conditions.

Propeller fan
The new propeller fan was carefully Superior corrosion
matched with a fan motor in order
to keep the same capacity as that of resistance
previous models with less electrical The base of the outdoor unit is hot
consumption. dipped to provide superior corrosion
and scratch resistance.

Outdoor unit
Redesigned by changing the fin configuration
from flat sheet to new M shape fin, efficiency
has been improved. An optimum balance of
heat transfer and air flow has been achieved.

MULTI series Air Conditioners 2013


-15C +46C
Cooling

-20 -10 0 10 20 30 40 50
For the capacities under low temperature conditions,
refer to technical manual. Applied models

Advanced Technology.
All SRK

ay life
our everyd

Comparis
on w ith familiar
noises in
21dB
nv ersations
Normal co
70dB

Anti-microbial indoor fan


e
Quiet offic
eryday life
s in our ev t in a
Compariso
n with fam
iliar noise
60dB
21dB
In the lib
rary Late nigh rban area
typical su
bu
tions
sadB
er50
Normal
70dB conv
Anti-microbial specifications and design will deliver cleanliness and safety Quiet offic
e
a
60dB 40dB rary Late night in
In the lib burban ar
ea
typical su

FEATURES
50dB

60dB 50dB 40dB 21dB


30dB
40dB
20dB 30dB
60dB10dB 50dB 21dB
30dB

20dB
40dB 30dB
SRK20ZJX-S
0dB
10dB (In the Cooling Lo mode)
SRK20ZJX-S
0dB
(In the Cooling Lo mode)

Applied models
-15C +21C
SRK-ZJX, SRK-ZK, Heating
SRK-ZJ, SRF-ZJX

-15C +46C
Cooling

-20 -10 0 10 20 30 40 50
For the capacities under low temperature conditions,
refer to technical manual.

Anti-microbial treatment All SRK, SRF, SRR, FDTC All SCM-appearance may vary
SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX
The indoor fan has undergone anti-microbial treatment to All SRK, SRF, SRR, FDTC All SCM-appearance may vary
resist growth of mould and germs. Mould creating odours
which can occurApplied
when an air conditioner is not in operation
models Comparison of growth of bacteriaSRK50/60ZJX, and SRK-ZK,
mold onSRK35/50ZJ,
ay life
fan surfaces
SRK-ZJX
our everyd
(microscopic mp
image) r noises in
21dB
All SRK, SRF
th familia
are prevented. arison wi
Co
ns
nversatio
Normal co
70dB
e

Washable filter and easy


Quiet offic a
Applied models 60dB rary Late night in
In the lib burban ar
ea
All SRK, SRF typical su
50dB

cleaning of the air inlet panel


40dB

without 30dB with without with


60dB 50dBAnti-microbial
Anti-microbial Anti-microbial
20dB
40dB 0dB 21dB
Anti-microbial
3
Removing the air filter is quite easy. Keeping the air filter 10dB
SRK20ZJX-S
clean is an effective way to save energy and keep the original 0dB
(In the Cooling Lo mode)

powerful performance of your unit.


The air inlet panel is models
Applied also removable and can be cleaned easily.
SRK50/60ZJX,
SRK-ZK Maximum pipe length
SRF-50ZJX
30m
Three sensors Maximum height difference
Aspergillus niger IFO 6341
20m Escherichia coli IFO 3972

Control of room temperature and humidity is very important for In tests conducted at the Mitsubishi Heavy Industries Nagoya Research Lab,
Applied models 24 hrs after contact with bacteria, cultured on agar media.
people to live a comfortable life. Use of three sensors to control
SRK50/60ZJX,
Maximum pipe length
indoor temperature,
SRK-ZK
indoor humidity and outdoor temperature
SRF-50ZJX
enable the unit to obtain optimum air-conditioning. 30m
Live Bacteria Count on Measured Test Pieces All SRK, SRF, SRR, FDTC
Maximum height difference
All SCM-appearance may vary
20m
Applied models
-15C +21C
Tested
SRK-ZJX, SRK-ZK, Bacteria Heating
Count
SRK50/60ZJX, PerSRK35/50ZJ,
SRK-ZK, Test Piece SRK-ZJX
SRK-ZJ, SRF-ZJX Measurement Test Pieces
Contaminant Measurement 1 Measurement 2 Measurement 3
Wide operation
Escherichia
Applied models coli range
Immediately after contact
Applied models
Not treated 1.9 x 105 -15C 1.6 x 105 Cooling 1.3 x 10+46C
5

IFO 3972
All SRK, SRF

colicoolingAfter 24 hrs Test piece 1 <10 -15C <10


Heating +21C <10
Heating and operations are possible
SRK-ZJX, SRK-ZK,
3.8 x 106 4.9 x 106 x 106
at 35C Not treated and mold on fan7.2surfaces
SRK-ZJ, SRF-ZJX
Comparison of growth of bacteria -20 -10 0 10 20 30 40 50
at an outdoor temperature as low
Immediately after contact as 15C
Not treated (microscopic
1.4 x 105 Forimage) low xtemperature
the capacities under1.6 105 conditions, 1.3 x 105
+46C
Staphylococcus refer-15C
to technical manual.
Cooling
Our advanced technology hasAfter improved
24 hrs the heating and
Test piece 1 cooling <10 <10 <10
aureus
operation range. Units can be installed or cooling 8.6 x 105 4.5 x 105 3.6 x 105
at 35C when heating
Not treated
operation is required at low ambient
Immediately conditions
after contact down
Not to -15C. 1.5 x 104
treated -20 -10 0 x 104 10
2.2 20 301.6 x 1040
4 50
Aspergillus For the capacities under low temperature conditions,

niger After 24 hrs Test piece 1 <10 refer to technical manual.


<10 <10
at 35C Not treated 1.0 x 104 1.2 x 104 2.5 x 104
Quiet operation
Test Pieces 1) Products with Antimicrobial and Antifungal Treatment
Applied models
Comparis
on with fam
iliar noise
s in our ev
eryday lif
e

21dB
ns
Silent airflow and long reach
SRK50/60ZJX,
nversatio
Maximum pipe length
Normal co
SRK-ZK 70dB
SRF-50ZJX
60dB 30m
Quiet offic
e
rary Late night in
In the lib
a
burban ar
ea
The secret of quiet operation 50dB Maximum height difference typical su
lif e
r everyday
The combination of the jet airflow system and serration 40dB
Comparis
on with fa 20m
miliar no
ises in ou
21dB
stabilizer configuration ensures uniform breeze to every ersations
60dB 50dB e 40dB 21dB
30dB

30dB
nv
Normal co
70dB

corner of the room. It also makes it possible to lower the 20dB Quiet offic a
rary Late night in
In the lib
60dB ea
burban ar
operation noise further by minimizing the interaction 10dB
typical su
50dB SRK20ZJX-S
between airflow and the fan. 0dB
40dB
(In the Cooling Lo mode)

60dB 50dB 40dB 21dB


30dB

30dB
20dB

10dB
9
SRK20ZJX-S
0dB
(In the Cooling Lo mode)
10 3D AUTO Vertical + Horizontal AIR SCROLL.

3 motors make 3 independent controls

3 motors make 3 independent controls

3 motors make 3 independent controls


3 motors make 3 independent controls

Programmedairdistribution
Programmedairdistribution

Applied models Applied mode


3D AUTO
3D AUTO
SRK-ZJX, SRK-ZJ
SRK-ZJX, SRK
3D AUTO is a one touch programme. Three motors (one vertical working motor
SRK63/71/80ZK,
Manual Setting only SRK63/71/80Z
+ two horizontal working motors) make three independent air flow controls. Manual Setting

The airflow is uniform, quiet and reaches at long distance from the indoor unit.

Programmedairdistribution
Programmedairdistribution

Programmed 3D AUTO
Hi-Power (Quick) Cool Shower Floor Heating
Manual Setting Applied mode
Applied model
3Dair
Automatic control of AUTO
3D flAUTO
ow volume and air flow direction
Swing Individual control
Vertical Swing of right and left louver enables air
SRK-ZJX, SRK-
SRK-ZJX, SRK-Z
SRK63/71/80ZK
SRK63/71/80ZK
1
enables comfortable air conditioning of the entire room. flow direction from the right and the left side of the Manual Setting o
Manual Setting o

In cooling operation, cooled air flows directly


Cool Shower FloortoHeating
the ceiling unit, setting the most preferable air flow direction and
Hi-Power
not (Quick)
Widedirectly onto
Swing (Every the occupants of the room. The comfort
Corner) determining whether direct air flow is required or not.
cooled air flow comes down from the ceiling like a soft Vertical Swing
Swing Swing
12
shower.
In heating operation, warm air flows to the floor directly
and spreads
Center (Long) along the floor. The concentrationHorizontal of the Air Scroll 8 Direction Swing
Wide
warm Swing
air at(Every
floor Corner)
level increases
Swing
comfort. 1 2 3 4
3
Swing Swing
2
Wide-Air (Equal)
Hi-Power
Hi-Power (Quick)
(Quick) Cool
Cool Shower
Shower Floor
Floor Heating 7
8Heating 6 5
Cool Shower
4 VerticalSwing
Vertical Swing
Center (Long) Swing
Swing Horizontal Air Scroll 8 Direction Swing
1 1 Floor
Swing
1
Spot Wide
2 3 4
Swing
3
WideWide Swing
Swing (Every
(Every Corner)
Corner) Swing

Wide-Air (Equal) Swing


Swing
2 2 8 7 6 5
Cool Shower
4Center (Long) HorizontalAir
AirScroll
Scroll88Direction
DirectionSwing
Swing
Center (Long) Horizontal
11 Swing 22 33 44
Floor
Swing Spot Wide

3 3
Swing
Swing
Swing

Wide-Air (Equal)
Wide-Air (Equal)
Cool Shower
88 77 66 55
4 Cool Shower
4
Floor
Floor Swing Spot Wide
Swing Spot Wide

MULTI series Air Conditioners 2013


Jet air scroll long reach & silent air flow.

FEATURES
Aircraft technology was used in the design of
the air conditioners airflow system Fast Slow
Colors in the figure show the air speed.

We used the same aerodynamic analysis technology as used in


developing jet engines.
CFD (computational fluid dynamics) is used for blade shape design and air channels for jet engines. The same
technology has been used in our air conditioners. The airflow of the jets created in this system enables a large volume of
air to be blown with a minimum amount of power consumption. The airflow is uniform, quiet and reaches a long distance
from the indoor unit.
SRK71ZK
SRK50/60ZJX (in cooling operation)
(in cooling operation)

Long Reach Air Flow


The jet technology enables powerful
airflow ideal for large living areas and
commercial premises, increasing your
comfort.

15m
powerful
17m

Positioning of Installation
You can set the left-right air flow directions when you
install the air conditioner near the side wall by remote
controller operation. New louver
The new louver has a new design and shape.It has
increased in surface area by 80%. In addition to improved
control of the increased air flow volume, it has improved
controllability of the right to left swing function.
80% increased
80% increased

previous
New

previous
New

11
12 Clean Air.
Allergen Clear System
The Allergen Clear system suppresses the influence of the allergen caught by the filter by controlling
the temperature and humidity.

AIR Purify
Heating Operation
Catching Allergen Cooling Operation To give moisture to the Self-Clean Operation
on the Filter To make condensing water. Filter to inactivate allergen To dry up the indoor unit

Stop
Stoprun
run 2hrs
2hrs
Stop run 2hrs
Normal
Normal Clean
Clean
operation
operation
Normal operation
operation
Clean
operation operation
Shutsoff
Shuts offautomatically
automatically
Shuts off automatically
After one week
without self clean opration
First in the world
Generates the same amount of negative 20 of Patent Pending Fungal
mycelia
Fungal
Fungal
ions as a forest environment mycelia
mycelia
Spore
The air in your room is kept fresh of mold
24-hour ION Spore
Spore
ofofmold
mold

The air conditioner body has a Allergen clear system After one week
tourmaline coated sheet. Negative ions The Allergen Clear system with self clean opration
(2,500 -3,000/cc) are generated even suppresses the influence of the
Situation of mold
allergen
Situation
when the air conditioner is not running, of caught
mold by the filter by
Situation after
ofone
moldweekthe temperature and
allowing you to experience them aftercontrolling
one week Spore
ofSpore
mold
without incurring any electricalafter
cost. one week
humidity. of mold
Spore
of mold

Situation
Situationofofmold
moldafter
afterone
oneweek
week
When you dont execute Self Clean Operation When you execute Self Clean Operation
Situation ofyou
When mold
dontafter one
execute Selfweek
Clean Operation When you execute Self Clean Operation

Fungal
When you mycelia
dont execute Self Clean Operation When you execute
Fungal mycelia
expand.
The
Thespore
spore moldSelf Clean Operation
ofofmold
expand. doesn't
doesn'tgerminate.
germinate.
Fungal mycelia The spore of mold
expand. doesn't germinate.

Self Clean Operation


The self clean operation is operated for
2 hours after the unit has ceased normal
operation. The indoor fan continues to
operate on ultra low speed to dry the unit.
This restricts the growth of mould. This
feature can be selected on the remote
control.

MULTI series Air Conditioners 2013


A molecule is decomposed
Urea Enzyme
Rate of inactivation against allergens collected on the filter
H2N-
Slack of high order structure Reduction in a molecule
99.9% 99.0%
100 -COOH 93.6%
83.5% 83.5%

Inactivation rate(%)
Protein structure of allergen 72.7%
Sterilization Mechanism
A molecule is decomposed
Sterilization Mechanism
Allergen clear filter H2N-
50 Urea Enzyme
Rate of inactivation against allergens collected on the filter
Sterilization Mechanism Urea
Slack of high order structure Reduction in a molecule
Enzyme 99.9% 99.0%
This is the original and only technology to control the temperature and
100 humidity
-COOH for93.6%
inactivating allergens
Sterilization Mechanism
83.5% 83.5%
Enzyme + Urea deactivates allergens and
H2N-

Inactivation rate(%)
Protein structure Urea
of allergen
Slack of high order structure Enzyme
72.7% Reduction in a molecule
0 Urea
-COOH Enzyme
Sterilization
House dust Mechanism
mite A species of miteA molecule
Cedar pollen is Epithelium
decomposed
of cat Virus i Virus p
kills bacteria H2N-

FEATURES
H2N-
Slack of high order structure Reduction in a molecule *1 *1 *2 *2 *3 *3
c method /
Rate of inactivation
Protein
50 against
structure
Urea of allergens
allergen collected
Enzyme on the filter -COOH
Slack of high order structure Reduction in a molecule
method
The allergen clear filter deactivates pollen lice and allergens -COOH
99.9% 99.0%
100 H2N-Protein structure
93.6% of allergen A molecule is decomposed
nistrative
ospital that live on cat skin etc. The deactivation secret is the Protein structure
83.5% of structure
Slack of high order allergen 83.5%
AReduction
molecule in a molecule
is decomposed

Inactivation rate(%)
-COOH
mihara
Enzyme-urea compound. It deactivates not only allergens Rate of inactivation againstagainst
allergensallergens
collected oncollected
filter on the filter
est method: 72.7% A molecule is decomposed
6
LISA colorimetric
Test method: method /
but some bacteria, moulds and viruses. Even if allergen, Rate of inactivation the 99.9%
Rate of inactivation
Protein against
structure of allergen allergens collected
99.9% on99.0%
the filter
LISA
ELISAfluorescent method
colorimetric method /
c method
aboratory: 0 99.0%
93.6% 93.6%
ELISA fluorescent method
50 100
dependent administrative
Laboratory:
nistrative
gency national
Independent
Test hospital
method: administrative
mould, virus or bacteria fly off the filter they are deactivated 100
100 83.5%
House dust
83.5%
mite A species of mite 83.5%
93.6%
A molecule
Cedar pollen99.9% is decomposed
Epithelium
83.5%
99.0%
of cat Virus i Virus p
*1 *1 83.5%*2 *2 *3 *3

rate(%)
Inactivation rate(%)
so the air in your room is kept fresh.
ospital
Rate of inactivation against allergens collected on the filter
mechanism
agency Sagamihara
national
ELISA colorimetric hospital
method / 83.5% 72.7%
mihara 72.7%

rate(%)rate(%)
ospital,fluorescent
mechanism
ELISA No.1536
Sagamihara
method
6est method:
72.7%
Hospital,
Laboratory:No.1536 99.9% 99.0%
LISA
Test colorimetric
method:
Independent method
administrative 100 93.6%
ue 50%)
aboratory: 0 50 83.5%

Inactivation
ELISA
agency colorimetric method
national hospital 83.5%
dependent administrative
Laboratory:
mechanism Sagamihara 5050dust mite A species of mite Cedar pollen
House Epithelium of cat Virus i Virus p

Inactivation
gency national hospital 72.7%
azato
Independent
Hospital, administrative
No.1536 *1 *1 *2 *2 *3 *3
mechanism
ence
agency
Test Sagamihara
Center,
national hospital
method:
ospital,colorimetric
mechanism
ELISA No.1536
Sagamihara
method
est method:

First in the world


Hospital,
Laboratory: No.1536 50

Inactivation
CID
Test (Infection value 50%)
method: administrative
Independent 0
aboratory:
TCID
agency (Infection
nationalvalue 50%)
hospital 0 House dust mite A species of mite Cedar pollen Epithelium of cat Virus i Virus p
oundation
mechanismofSagamihara
Laboratory: Kitazato House*1dust mite A species
*1 of mite *2 pollen Epithelium
Cedar *2 of cat *3 i
Virus *3 p
Virus
nvironmental
Foundation ofScience
Hospital, No.1536 KitazatoCenter, 0 *1 *1 *2 *2 *3 *3
o.15-0145
Environmental
Test method: Science Center, House dust mite A species of mite Cedar pollen Epithelium of cat Virus i Virus p
No.15-0145
TCID (Infection value 50%)
Laboratory:
Conventional
0 *1 Filter *2
*1
House dust mite A species of mite Cedar pollen Epithelium of cat Virus i
Enzyme
*2
Virus p
*3 Filter*3
Foundation of Kitazato *1 *1 *2 *2 *3 *3
Environmental Science Center,
No.15-0145

Airflow
Natural enzyme filter
First in Filter
the world
Analysis Zone First in the world Analysis Zone

Helps to destroy fungi and bacteria, also effective on viruses and allergenic compounds
Conventional Enzyme Filter
(Cat hair, dust mite, pollen etc.) Conventional Filter Enzyme Filter
First
Firstininthe
theworld
world
Enzyme filter
Enzyme's Filtersterilizing mechanism

Airflow
Conventional Enzyme Filter

Airflow
The enzymes used in these filters are naturally occurring
FirstZone
Conventional Filter
Analysis
Analysis Zone in the world
Enzyme Filter
Analysis Zone Analysis Zone
First inEnzyme
the world
lytic enzymes. Lytic enzymes attack cell walls of

Airflow
microorganisms trapped on the filter and destroy them. Conventional Filter
Bacterium Filter

Airflow
Analysis Zone
Enzyme Analysis Zone Enzyme
The Natural Enzyme Filter will clean and sanitize air Analysis Zone Analysis Zone
Conventional Filter Enzyme Filter
passing through it. Enzyme's sterilizing mechanism
Airflow

Coupling
Enzyme's
Analysis Zone
sterilizing mechanism
Analysis Zone
Enzyme's
Bacterium sterilizing mechanism Airflow Powerful
Enzyme's sterilizing
Enzyme
Cell wall mechanism Enzyme
sterilizing effect
Filter fiber
Analysis Zone
Bacterium Analysis Zone
Bacterium
Enzyme's
EnzymeEnzyme sterilizing mechanism
Bacterium Enzyme Enzyme
Enzyme Enzyme
Coupling
Cell wall Powerful
Bacterium sterilizing effect
Filter fiber
Coupling Enzyme
Enzyme
Powerful
Coupling
Enzyme's sterilizing mechanism
Coupling
Filter fiber
Cell wall
Cell wall
Cell wall Powerful effect
sterilizing
sterilizing effect
Powerful
Filter fiber
Filter fiber sterilizing effect
Coupling
Cell wall Powerful
Bacterium sterilizing effect
Filter fiber
Enzyme Enzyme

Photocatalytic washable deodorizing filter


The deodorizing ability of this filter can be easily restored simply byCoupling
cleaning and exposing to sunlight
Cell wall Powerful
This filter will keep the air fresh by deodorizing the molecules that Filter fiber sterilizing effect
cause odours. The deodorizing effect can be restored by washing
with water and then drying under the sun. This filter maintains its
deodorizing effect even after many repeat uses.

Used Used
in models
in models
Used in models
UsedFilter
in models
Filter
Indoor Unit Unit SRK-ZJX
Indoor
Indoor Unit
SRK-ZJX
SRK-ZJX
SRK-ZK
SRK-ZK
SRK-ZK
SRK-ZJ
SRK-ZJ
SRK-ZJ
SRF-ZJX
SRF-ZJX
SRF-ZJX
Filter
Used
Allergen Clear in
Allergen models
Filter
Clear Filter 1pc
Indoor Unit 1pc
1pc
1pc 1pc
1pc --
Filter Allergen Clear Filter SRK-ZJX1pc
1pc SRK-ZK
1pc SRK-ZJ
- SRF-ZJX
NaturalNatural
Enzyme Filter Filter
Filter Enzyme Indoor Unit - -
SRK-ZJX - -
SRK-ZK --
SRK-ZJ 1pc
1pc
SRF-ZJX
Natural Enzyme Filter - - - 1pc
Allergen Clear
Photocatalytic
Filter
Photocatalytic
Washable
Allergen Washable
Clear Filter Deodorizing
Deodorizing Filter Filter 1pc1pc
1pc
1pc1pc
1pc
1pc
1pc
1pc
1pc
1pc
1pc
1pc
1pc
-
-
Photocatalytic Washable Deodorizing Filter 1pc 1pc 1pc 1pc
Natural Enzyme NaturalFilter
Enzyme Filter - - - -- -
1pc 1pc
Used in models
PhotocatalyticPhotocatalytic
Washable Washable Deodorizing
Deodorizing FilterFilter 1pc 1pc 1pc 1pc1pc 1pc
1pc 1pc
13
Filter Indoor Unit SRK-ZJX SRK-ZK SRK-ZJ SRF-ZJX
14 Ceiling Concealed Type.

Wired Remote Control Wireless

RC-EX1A RC-E5 RCH-E3 RCN-TC-

Standard
SRR25~60VF Equipment

Ceiling concealed type (SRR)


Models SRR25ZJ-S, 35ZJ-S, 50ZJ-S, 60ZJ-S Unit:mm
325.4 Symbol Content
Control Box
SRR25ZJ-S, SRR50ZJ-S,
D Model
35ZJ-S 60ZJ-S
30

9.52 3 8" 12.7 1 2"


A Gas piping
Flare Flare
E B Liquid piping 6.35 1 4" Flare
515 (Suspension bolts pitch)

C Drain piping VP16


D Suspension bolts M8
455

E Power supply intake 35


253

Wireless remote controller Wired remote controller


Option

150
30

35 670 (Suspension bolts pitch) 35


60 17.3 120 19

740 105.7 Note 1 The model name label is attached


105 220 90 220 105 on the lid of the control box.
Terminal block 2 It takes the interface kit SC-BIKN-E
11.2
19

to connect the wired remote controller.


30

Air outlet
B
148
170

230

150
52
41

FIG.B
30

100 540 100 8- 2.8


Holes for tapping screws 4
C Air inlet A
FIG.A 135 38
236 75

6-M4 82 574 84
For hanger plate
32
20
174.4

177
120
30.3

21

40 40
18.5 703 18.5 35 670 35
In case of filter guide installed
(normal condition)
In case of filter guide installed
(option)
FIG.A
(Air inlet from lower) FIG.B
(Air inlet from rear)

15 710 15
5- 3.3( Mark only) 168 168 168 168
Holes for tapping screws 4 11- 2.8
Holes for tapping screws 4 10 24 24 10
40
190
160

80 40
13

203.7
150
11
15

80

9- 2.8
Holes for tapping screws 4
10 24 24 10
11.3
20

168 168 168 168


15 710 15 23 694 23
In case of filter guide taken off In case of rear panel taken off

MULTI series Air Conditioners 2013


Wired Remote Control
Ceiling Cassette.
Wired Remote Control
Fits into standard Wired Remote Control
600 x 600 ceiling
RC-EX1A RC-E5 RCH-E3

PRODUCTS
Fits into standard Wired Remote Control
600 x 600 ceiling
Fits into standard
600 x 600 ceiling
RC-EX1A RC-E5 RCH-E3
Wireless Remote
RC-EX1A Control
RC-E5
Wired Remote RCH-E3
Control
Fits into standard
Wired Remote
Wireless Control
Remote Control
600 x 600 ceiling RC-EX1A RC-E5 RCH-E3
Fits into standard
600 x 600 ceiling Wireless Remote Control

Wireless
RC-EX1A Remote
RC-E5 Control
RCH-E3

Wireless Remote Control


FDTC25~60VF RC-EX1A RC-E5 RCH-E3
RCN-TC-24W-ER
FDTC25~60VF RCN-TC-24W-ER
RCN-TC-24W-ER
Wireless Remote Control
FDTC25~60VF FDTC25~60VF RCN-TC-24W-ER
RCN-TC-24W-ER

Taking outside air inside Quiet operation


OA Spacer TC-OAS-E (option) (Sound
(dB) Pressure level in the Lo mode)
Joint Duct TC-OAD-E (option) 36
35dB 3dB
FDTC25~60VF (dB)
RCN-TC-24W-ER Down
36 35
(dB)
35dB
36
3dB
3dB
Utilizing OA spacer which comes 35 34
35
35dB Down
Down
as optional equipment, outside air Indoor Unit FDTC 34
(dB)
33
34 32dB
can be taken inside. Indoor Unit FDTC Indoor Unit FDTC
(dB) 36
33 32
33
35dB 32dB
32dB 3dB
3dB
Down
32
36 35
32 31
30dB
35dB31 31
30dB
Down
Using 1 joint duct: 30
35
34 30
30dB
OA comes up to 1.3m3/min. OA Indoor Unit
OA FDTC 300mm
300mm
30 29
29
5dB5dB
33 28 Down 32dB
28
5dB Down
Spacer
Using 2 joint ducts: Spacer 34 300mm 29
32
(dB) 27
OA
OA comes from 1.3 to 2.6m3/min. Ceiling OA 36 28 27
26
35dB Down 3dB
Indoor Unit FDTC
OA31
30dB
32dB
Spacer surface
Ceiling OA 33OA Panel
35
Joint Duct27 26
25
Down
surface 30
Ceiling OA OA 32
Panel Joint Duct 34 26 25 Previous New New
surface
IndoorPanel
Unit FDTC Joint Duct
300mm 29 (Cooling/Heating) 5dB
(Cooling) (Heating)
OA 33 25
Down 32dB
Spacer 31 32
28
27
Previous
30dB
(Cooling/Heating) New (Cooling)
Previous
New New
New (Heating)
Ceiling OA
30 31
26 (Cooling/Heating) (Cooling) 30dB (Heating)
OA
30
CLEARERair flow Compact
5dB and
5dB convenient
surface
300mmPanel 29Duct
Joint 25 Flexible hose
300mm 29

Down
OA
r Spacer
28 28 Previous Down New
600mm
New
New shape & angled louver
redirects the air current 600mm drain pump 248mm

27 27 (Cooling/Heating) (Cooling) (Heating)


away from the ceiling, to reduce ceiling stains Drain can be discharged upward by 600 hose
Flexible mm from
Ceiling OA OA 26
eiling OA 26 the ceiling surface close toFlexible
the indoor
hose unit.
OAsurface Panel Joint Duct 25
It allows a piping layout with a high degree of freedom 600mm
face 248mm
Panel Joint Duct 25 depending on the
Previousinstallation location.
New
600mm
New
248mm
(Cooling/Heating) (Cooling) (Heating)
wireless
remote control
Previous
600 x 600 ceiling New
Flexible hose New
Indoor unit size (W:570(Cooling)
(Cooling/Heating) x D:570) brings easy
(Heating)
RCN-TC-24W-ER 600mm
installation for 600 x 600 ceiling and Panel size (700
x 700) is suitable248mm
for 600 x 600 ceiling. Height is one
of the industry's lowest level at 248mm and weight is
16.5kg only. Flexible hose
wireless 600mm

Easy installation
wirelessremote control 248mm
remote control
RCN-TC-24W-ER
For wireless control simply insert the RCN-TC-24W-ER
infrared receiver Flexible hose
kit on a corner of the panel
wireless 600mm
remote control 248mm
RCN-TC-24W-ER

wireless
remote control
RCN-TC-24W-ER

15
16 Floor Standing.

Wired Remote Control Wireles

RC-EX1A RC-E5 RCH-E3 RCN-T

Wired Remote Control Wireless Remote Control

RC-EX1A RC-E5 RCH-E3 RCN-TC-24W-ER

SRF25~50ZJX
SRF25ZJX-S, SRF35ZJX-S, SRF50ZJX-S

Sophisticated design
With a classy semi flat front panel in chic white, this series fits in all
kinds of rooms and creates a relaxing atmosphere. Choice of wall
hanging, floor standing or behind gallery installation is available.

Auto air outlet selection


Heating operation:
When both lower and upper outlets operation and the Auto fan speed
mode is selected, the lower outlet will be kept closed for twenty
minutes after the start or until room temperature is close to reaching
the set point. Then the air outlet will change to both outlets. That state
will be maintained until the switch is turned off.
Automatic adjustment of lower air outlet direction prevents stirring up
of warm air and keeps optimum comfort at floor level.

Cooling operation:
When both lower and upper outlets operation is selected in Cooling Right
or Dry operation, both outlets are kept open for sixty minutes after the
start or until room temperature is below set point. Then the air outlet Rear
will change to the upper outlet. That state will be maintained until unit Downward Left rear Left
is switched off. Left downward
In case both outlets operation with Auto fan speed mode is selected,
the upper outlet will be kept closed for ten minutes after the start or
until room temperature is close to reaching the set point. Then the Right
air outlet will change to both outlets in order to spread comfort air to
every corner.
Rear

Left rear Left


Easy installation Downward
Left downward
Piping and drain hose connection can be selected out of 6-directions.

Right
Right
Convenient to use
Rear
operation
Rear simultaneous lower and upper air outlets or
Besides on/off operation,
Left rear Left
upper outlet can be selectedDownward
Downward by Left
the air flow direction
rear Leftbutton. Further
control can be selected on the remoteLeft downward
control.
Left downward

MULTI series Air Conditioners 2013


RC-EX1A RC-E5 RCH-E3 RCN-KIT3-E

Ceiling Concealed Type Medium Static.

PRODUCTS
Wired Remote Control Wireless Remote

UM50VF
RC-EX1A RC-E5 RCH-E3 RCN-KIT3-E

Wired Remote Control Wireless Remote Control

FDUM50VF

FDUM50VF RC-EX1A RC-E5 RCH-E3 RCN-KIT3-E

FDUM50VF

Low profile
The height of FDUM50 model is only 280mm. 280
280

280

Improved servicing Pipe


Fan unit (impeller and motor) can be pulled out Unit Fan unit
from the right side of the unit. Maintenance is Maintenance
available from the right side or from beneath. hole

Service
space
Flexible hose
less than
600mm
600mm drain pump
Drain can be discharged upwards by 600mm
from the ceiling surface. It allows a piping layout
Flexible hose
with a high degree of freedom depending on the
installation location. less than
600mm

Flexible hose
less than
600mm 17
18 Ceiling Suspended.

Wired remote control

RC-E5 RCH-E3

Wireless remote control

FDEN50VF RCN-E-E

Easy installation
Increased freedom of a piping layout Up
The refrigerant pipe from the unit can be arranged in
three directions, rear, right and up. The drain pipe can be
arranged in two directions, left and right. This will allow Right
a free layout of piping for various installation conditions. Rear
The unit can only be serviced from below.

Compact and modern design


All models fit compactly on the ceiling. Height is 210mm.
Up
Elegant, modern design featuring rounded edges gives the
room a comfortable atmosphere.
Height
Right 210mm
Rear

MULTI series Air Conditioners 2013


Control Options.
CnT terminal is equipped
CnT terminal is equiped

PRODUCTS
XR1
CnT XR2
XR3
XR4

XR5 Remote surveillance


XR1~4 : DC12v XR5 : 220~240V system

common HOTEL

XR1 output1 (run)

HOTEL
XR2 output2 (heat) Power
XR3 output3 (comp on) source
XR4 output4 (alarm)
XR5 in put
Card key on-off
Wired Remote Control Wireless Remote Option Super Link Network

Model Interface Wired Remote Control Infrared Kit Interface Wired Remote Control

SRK**ZJ-S
SRK**ZJ-S1
SRK**ZJX-S
SRK**ZJX-S1 SC-BIKN-E
SC-BIKN-E Not required
SRK71ZK-S SC-ADNA-E
Options RC-EX1A Options RC-EX1A
SRF**ZJX-S
RC-E5 RCH-E3 RC-E5 RCH-E3
SRF**ZJX-S1
SRR**ZJ-S
FDUM50VF RCN-KIT3-E
FDTC**VF Not required RCN-TC-24W-ER SC-ADNA-E
FDEN50VF RCN-E-E
SCM40ZJ SCM50/60ZJ SCM71/80ZJ SCM100ZJ SCM125ZJ
length for one indoor unit under 25m under 25m under 25m under 25m under 25m

Refrigerant Pipe Length


height
total length for all rooms
lower installation spot of the indoor unit (A)
upper installation spot of the indoor unit (B)
under 30m
under 15m
under 15m
under 40m
under 15m
under 15m
under 70m
under 20m
under 20m
under m
under m
under m
under m
under m
under m
difference
Limit - The maximum piping length of the refrigerant pipes for the outdoor units, and the maximum
maximum height difference of the indoor units (C) under 25m under 25m under 25m under m under m
height difference for the outdoor units are as shown below.
precharged to refrigerant pipe length 30m 40m 40m m m

SCM40ZJ-S SCM50/60ZJ-S SCM71/80ZJ-S SCM100ZJ-S SCM125ZJ-S

B B
B B B
C C C C C

A A A A

Maximum refrigeration pipe run metres SCM40ZJ SCM50/60ZJ SCM71/80ZJ SCM100/125ZJ


length for one indoor unit 25
total length for all rooms 30 40 70 90
lower installation spot of the indoor unit (A)
height 15 20
upper installation spot of the indoor unit (B)
difference
maximum height difference of the indoor units (C) 25
pre charged to refrigerant pipe length 30 40 50

19
20 Inverter Multi-Split System.
SCM-ZJ
The multi system allows a single outdoor unit to service up to six indoor units.

Wall mounted type SRK Ceiling concealed type SRR 4way ceiling cassette type FDTC

Duct connected type FDUM

Individual refrigerant circuit


for each indoor unit

Floor type SRF Ceiling suspended type FDEN

Outdoor Unit

SCM40ZJ-S1 / SCM50ZJ-S1
SCM60ZJ-S1 SCM71ZJ-S1 / SCM80ZJ-S1 SCM100ZJ-S1/ SCM125ZJ-S1

MULTI series Air Conditioners 2013


SCM40ZJ-S SCM50ZJ-S1 SCM60ZJ-S1 SCM71ZJ-S1 SCM80ZJ-S1 SCM100ZJ-S1 SCM125ZJ-S1

2 Rooms 2~3 Rooms 2~4 Rooms 4~5 Rooms 4~6 Rooms

Power Supply Outdoor 1 Phase 230V 50Hz

Cooling T1 kW 4.0(1.8~5.9) 5.0(1.8~7.1) 6.0(1.8~7.5) 7.1(1.8~8.8) 8.0(1.8~9.2) 10 12.5


Rated Capacity
Heating H1 kW 4.5(1.4~6.9) 6.0(1.4~7.5) 6.8(1.5~7.8) 8.6(1.5~9.4) 9.3(1.5~9.8) 12 13.5
Cooling T1 kW 0.84 1.08 1.43 1.74 2.16 2.86 3.9
Electrical Input
Heating H1 kW 0.90 1.31 1.51 2.00 2.26 2.93 3.25
EER Cooling T1 4.76 4.63 4.20 4.08 3.70 3.5 3.21
COP Heating H1 5.00 4.58 4.50 4.30 4.12 4.1 4.15
Cooling T1 A 3.7 4.7 6.5 7.6 9.4 12.4 17
Current
Heating H1 A 4 5.8 6.8 8.8 10 12.8 14.1
Rec Circuit Breaker A 25A
Cooling (Outdoor) dB (A) 60 62 63 65 66 68 69
Sound Power Level (JIS C9612)
Heating (Outdoor) dB (A) 62 65 65 66 66 71 72
External Dimensions (HXWXD) mm 640X850X290 750X880X340 945X970X370
Net weight Outdoor kg 47 48 49 62 92
Liquid Line mm 6.35 X 2 6.35 X 3 6.35 X 3 6.35 X 4 6.35 X 4 6.35 X 5 6.35 X 6
Gas Line mm 9.52 X 2 9.52 X 3 9.52 X 3 9.52 X 4 9.52 X 4 9.52 X 5 9.52 X 6
Refrigerant Piping
Union mm (9.52 12.7) X 1 (9.52 12.7) X 2 (9.52 12.7) X 2 (9.52 12.7) X 2 (9.52 12.7) X 2 (9.52 12.7) X 2
Connection Method Flare connection
Volume kg 2.0 2.5 3.15 6
Refrigerant R410A
Pre-Charged 30 mtrs 40 mtrs 50 mtrs
SRK*ZJS/S1 2.0,2.5,3.5 2.0,2.5,3.5,5.0 2.0,2.5,3.5,5.0
SRK*ZJX 2.0,2.5,3.5 2.0,2.5,3.5 2.0,2.5,3.5 2.0,2.5,3.5
SRK*ZJX-S1 5.0 5.0,6.0 5.0,6.0
SRK*ZK-S 7.1
kW
SRF*ZJX 2.5,3.5 2.5,3.5 2.5,3.5
Indoor Unit Combination
SRF*ZJX-S1 5.0 5.0 5.0
SRR*ZJ 2.5,3.5 2.5,3.5,5.0 2.5,3.5,5.0,6.0
FDTC*VD 2.5,3.5 2.5,3.5,5.0 2.5,3.5,5.0,6.0
FDUM*VF 5.0
FDEN*VF 5.0
Indoor Unit Connection 2 Units 2 to 3 Units 2 to 4 Units 4 to 5 Units 4 to 6 Units
Indoor Connection Capacity kW 4.0kW to 6.0kW 4.0kW to 8.5kW 4.0kW to 11.0kW 4.0kW to 12.6kW 4.0kW to 13.5kW 8.0 kW to 16kW 8.0kW to 19.5kW

Notes
1 Rated data is measured using SRK*ZJX indoor units to match the outdoor unit capacity
2 Currently there is no energy labelling standard for this type of product
3 The kW output capacity, electrical input, current and recommended circuit breaker are indicated at rated kW output capacity. Electrical work must be carried out by a suitably qualified person and comply to all electrical
standards and local regulations.

PRODUCTS

21
22 Multi System Indoor Unit.

SRK-ZJX
High COP wall mount type

Series
FUNCTION
Comfortable Functions
Self Clean Allergen SUN
Operation Filter Filter
Comfortable Air Flow Functions Convenient & Economy Functions Maintenance & Prevention Functions Others
Auto Flap Memory UP/DOWN Lateral Positioning
of
Economy
DRY
OFF Timer Sleep
24h Timer
On Timer
MC Self
Diagnostic
Detachable Back-up Auto
Switch Restart 24h ION
Luminous
Swing installation
Auto

SPECIFICATIONS
Item Model SRK20ZJX-S SRK25ZJX-S SRK35ZJX-S SRK50ZJX-S SRK60ZJX-S
Cooling capacity kW 2.0 2.5 3.5 5.0 6.0
Heating capacity kW 2.5 3.1 4.5 5.8 6.8
Cooling dB(A) 53 55 58 60 62
Sound power level *
Heating dB(A) 54 58 59 62 62
Cooling dB(A) Hi:39 Me:30 Lo:21 Hi:41 Me:31 Lo:22 Hi:43 Me:33 Lo:22 Hi:47 Me:40 Lo:27 Hi:51 Me:41 Lo:29
Sound pressure level *
Heating dB(A) Hi:38 Me:33 Lo:25 Hi:41 Me:34 Lo:27 Hi:42 Me:35 Lo:27 Hi:48 Me:40 Lo:33 Hi:48 Me:41 Lo:34
Cooling 191-133-83 208-150-83 225-158-83 225-183-133 241-208-141
Air flow Indoor l/s
Heating 200-158-116 216-166-125 233-183-134 275-241-175 283-250-183
Exterior dimensions (H X W X D) mm 309X 890X 220
Net weight kg 15
Clean filter Allergen Clear Filter X 1, Photocatalytic Washable Deodorizing Filter X 1
Liquid line mm 6.35
Piping
Gas line mm 9.52 12.7
OUTDOOR UNITS TO BE COMBINED SCM40~125ZJ-S1 SCM50~125ZJ-S1 SCM60~125ZJ-S1
The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.
*

SRR-ZJ
Ceiling concealed type

FUNCTION
Comfortable Functions Convenient & Economy Functions Maintenance & Prevention Functions Others
Self Clean Economy OFF Timer Sleep On Timer
MC Self
Diagnostic
Back-up Auto Luminous
Switch Restart
Operation DRY 24h Timer

SPECIFICATIONS
Model SRR25ZJ-S SRR35ZJ-S SRR50ZJ-S SRR60ZJ-S
Cooling capacity kW 2.5 3.5 5.0 6.0
Heating capacity kW 3.4 4.5 5.8 6.8
Cooling dB(A) 54 56 60 63
Sound power level*
Heating dB(A) 55 57 60 63
Cooling dB(A) Hi:40 Me:35 Lo:29 Hi:42 Me:37 Lo:30 Hi:48 Me:42 Lo:33 Hi:51 Me:44 Lo:35
Sound pressure level *
Heating dB(A) Hi:41 Me:38 Lo:31 Hi:43 Me:40 Lo:32 Hi:48 Me:45 Lo:36 Hi:51 Me:47 Lo:38
Cooling 142 150 175 208
Air flow Qty (Hi) l/s
Heating 167 183 217 250
Exterior dimensions(H X W X D) mm 230x740x455
Net weight kg 22 23
Liquid line mm 6.35 6.35
Piping mm
Gas line 9.52 12.7
OUTDOOR UNITS TO BE COMBINED SCM40~125ZJ-S1 SCM50~125ZJ-S1 SCM60~125ZJ-S1

MULTI series Air Conditioners 2013


Multi System Indoor Unit.

PRODUCTS
SRF-ZJX
Floor type

FUNCTION
Comfortable Functions Comfortable Air Flow Functions Convenient & Economy Functions Maintenance & Prevention Functions Others
Self Clean Enzyme SUN
Operation Filter Filter
Auto Flap Memory UP/DOWN Air outlet
selection
Economy OFF Timer Sleep
DRY 24h Timer
On Timer
MC Self
Diagnostic
Detachable Back-up Auto
Switch Restart
Luminous

SPECIFICATIONS
Model SRF25ZJX-S SRF35ZJX-S SRF50ZJX-S
Cooling capacity kW 2.5 3.5 5.0
Heating capacity kW 3.4 4.5 5.8
Cooling dB(A) 51 52 58
Sound power level *
Heating dB(A) 51 52 58
Cooling dB(A) Hi:40 Me:32 Lo:26 Hi:41 Me:34 Lo:28 Hi:46 Me:42 Lo:32
Sound pressure level *
Heating dB(A) Hi:40 Me:35 Lo:28 Hi:41 Me:36 Lo:31 Hi:47 Me:41 Lo:33
Cooling 150-126-96 153-130-106 191-160-110
Air flow Indoor l/s
Heating 175-136-110 178-138-123 200-166-126
Exterior dimensions (H X W X D) mm 600X 860X 238
Net weight kg 18 19
Clean filter Natural Enzyme FilterX1 Photocatalytic Washable Deodorizing FilterX1
Liquid line mm 6.35
Piping
Gas line mm 9.52 12.7
OUTDOOR UNITS TO BE COMBINED SCM40~125ZJ-S1 SCM50~125ZJ-S1
The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.
*

SRK-ZJ-S1
Wall mount type

FUNCTION
Comfortable Functions
Self Clean Allergen SUN Series
Operation Filter Filter
Comfortable Air Flow Functions Convenient & Economy Functions Maintenance & Prevention Functions Others
Auto Flap Memory UP/DOWN Lateral Positioning
of
Economy
DRY
OFF Timer Sleep
24h Timer
On Timer
MC Self
Diagnostic
Detachable Back-up Auto Luminous
Switch Restart
Swing installation
Auto

SPECIFICATIONS
Model SRK20ZJ-S/S1 SRK25ZJ-S/S1 SRK35ZJ-S/S1 SRK50ZJ-S/S1
Cooling capacity kW 2.0 2.5 3.5 5.0
Heating capacity kW 2.7 3.2 4.0 5.8
Cooling dB(A) 49 50 58 61
Sound power level *
Heating dB(A) 52 55 59 61
Cooling dB(A) Hi:33 Me:27 Lo:21 Hi:34 Me:28 Lo:21 Hi:42 Me:32 Lo:22 Hi:46 Me:37 Lo:26
Sound pressure level *
Heating dB(A) Hi:36 Me:31 Lo:24 Hi:39 Me:31 Lo:24 Hi:43 Me:37 Lo:25 Hi:45 Me:37 Lo:31
Cooling 130-93-80 131-100-83 168-106-83 188-130-88
Air flow Indoor l/s
Heating 163-105-83 176-108-85 213-156-101 225-170-125
Exterior dimensions (H X W X D) mm 294X 798X 229
Net weight kg 9.5
Clean filter Allergen Clear Filter X 1, Photocatalytic Washable Deodorizing Filter X 1
Liquid line mm 6.35
Piping
Gas line mm 9.52 12.7
OUTDOOR UNITS TO BE COMBINED SCM40~125ZJ-S1 SCM50~125ZJ-S1

23
24 Inverter Multi Split System.

SRK-ZK
Wall mounted type

FUNCTION Series
Comfortable Functions
Self Clean Allergen SUN
Operation Filter Filter
Comfortable Air Flow Functions Convenient & Economy Functions Maintenance & Prevention Functions Others
Auto Flap Memory Air Scroll UP/DOWN Lateral
Swing
Economy
DRY
OFF Timer Sleep
24h Timer
On Timer
MC Self
Diagnostic
Detachable Back-up Auto
Switch Restart 24h ION
Luminous

SPECIFICATIONS
Item Model SRK71ZK-S
Nominal cooling capacity kW 7.1
Nominal heating capacity kW 8.0
Cooling dB(A) 60
Sound power level *
Heating dB(A) 61
Cooling dB(A) Hi:49 Me:45 Lo:39 Ulo:26
Sound pressure level *
Heating dB(A) Hi:46 Me:43 Lo:38 Ulo:35
Cooling Hi:19.5 Me:17.5 Lo:14.0 Ulo:8.0
Air flow CMM
Heating Hi:21.5 Me:19.5 Lo:15.5 Ulo:14.0
Exterior dimensions (H X W X D) mm 318x1098x248
Net weight kg 15
Clean filter Allergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1
Liquid line mm 6.35
Piping
Gas line mm 15.88
OUTDOOR UNITS TO BE COMBINED SCM100/125ZJ-S1

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.
*

FDEN-VF
Ceiling suspended

Wired Remote Control Wireless Remote Control

FUNCTION
Comfortable Functions Comfortable Air Flow Functions Convenient & Economy Functions Maintenance & Prevention Functions Others
RCN-E-E
Auto Flap Memory UP/DOWN
DRY
OFF Timer Sleep
24h Timer
On Timer
MC Self
Diagnostic
Back-up Auto
Switch Restart
RC-E5 RCH-E3

SPECIFICATIONS
Item Model FDEN50VF
Nominal cooling capacity kW 5.0
Nominal heating capacity kW 5.8
Cooling dB(A) Hi:39 Me:38 Lo:37
Sound pressure level *
Heating dB(A) Hi:39 Me:38 Lo:37
Cooling CMM Hi:11 Me:9 Lo:7
Air flow
Heating CMM Hi:11 Me:9 Lo:7
Exterior dimensions (H xW xD) mm 210x1070x690
Net weight kg 28
Air filter Pocket Plastic net x 2 (Washable)
Liquid line mm 6.35
Piping
Gas line mm 12.7
OUTDOOR UNITS TO BE COMBINED SCM50~125ZJ-S1
The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
* Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level:Cooling dB(A):46 Heating:46, Air flow:13CMM

MULTI series Air Conditioners 2013


Inverter Multi Split System.

FDTC-VF

PRODUCTS
Fits into standard
600 x 600 ceiling

4way ceiling cassette type

Wired Remote Control Wireless Remote Control

FUNCTION
Comfortable Functions Comfortable Air Flow Functions Convenient & Economy Functions Maintenance & Prevention Functions Others
OFF Timer Sleep
Auto Flap Memory UP/DOWN
DRY 24h Timer
On Timer
MC Self
Diagnostic
Back-up Auto
Switch Restart
RC-EX1A RC-E5 RCH-E3 RCN-TC-24W-ER

SPECIFICATIONS
Item Model FDTC25VF FDTC35VF FDTC50VF FDTC60VF
Nominal cooling capacity kW 2.5 3.5 5.0 6.0
Nominal heating capacity kW 3.4 4.5 5.8 6.8
Cooling dB(A) Hi:36 Me:32 Lo:29 Hi:40 Me:36 Lo:30 Hi:42 Me:36 Lo:30 Hi:46 Me:39 Lo:30
Sound pressure level *
Heating dB(A) Hi:38 Me:33 Lo:29.5 Hi:42 Me:35 Lo:32 Hi:42 Me:36 Lo:32 Hi:46 Me:39 Lo:32
Cooling CMM Hi:9 Me:8 Lo:6.5 Hi:9.5 Me:9 Lo:7 Hi:11.5 Me:9 Lo:7 Hi:13.5 Me:10 Lo:7
Air flow
Heating CMM Hi:9.5 Me:8.5 Lo:7 Hi:10 Me:9 Lo:8 Hi:11.5 Me:9 Lo:8 Hi:13.5 Me:10 Lo:8
Exterior dimensions Main unit mm 248x570x570
(H X W X D) Panel mm 35x700x700
Main unit kg 15
Net weight
Panel kg 3.5
Liquid line mm 6.35 6.35
Piping
Gas line mm 9.52 12.7
OUTDOOR UNITS TO BE COMBINED SCM40~125ZJ-S1 SCM50~125ZJ-S1 SCM60~125ZJ-S1
The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
* Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound level dB(A):25VF(Cooling:38 Heating:39), 35VF(Cooling:41 Heating:43), 40/50/60VF(Cooling:47 Heating:47), Air flow:25VF(Cooling:10 Heating:10.5), 35VF(Cooling:11 Heating:11.5),
50/60VF(Cooling:13.5 Heating:13.5)

FDUM-VF
Ducted connected-low/middle
static pressure

Wired Remote Control Wireless Remote Control


Filter KIT
UM-FL1EF (option)
FUNCTION
Comfortable Functions Convenient & Economy Functions Maintenance & Prevention Functions Others
OFF Timer Sleep
DRY 24h Timer
On Timer
MC Self
Diagnostic
Back-up Auto
Switch Restart RC-EX1A RC-E5 RCH-E3 RCN-KIT3-E

SPECIFICATIONS
Item Model FDUM50VF
Nominal cooling capacity kW 5.0
Nominal heating capacity kW 5.8
Cooling dB(A) Hi:32 Me:29 Lo:26
Sound pressure level *
Heating dB(A) Hi:32 Me:29 Lo:26
Cooling CMM Hi:10 Me:9 Lo:8
Air flow
Heating CMM Hi:10 Me:9 Lo:8
Exterior dimensions (H xW xD) mm 280x750x635
Net weight kg 29
Air filter Procure locally
Liquid line mm 6.35
Piping
Gas line mm 12.7
OUTDOOR UNITS TO BE COMBINED SCM50~125ZJ-S1
The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
* Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level dB(A):Cooling:37 Heating:37, Air flow:13CMM
25
26 Dimension Outdoor Unit.
Models SCM40ZJ-S, 45ZJ-S Models SCM50ZJ-S1, 60ZJ-S1
SCM40ZJ-S SCM50ZJ-S1 SCM60ZJ-S1
286.4 50
286.4
D E
50
12
D E 12

13.5
13.5

43.5
43.5

Examples of
Installation Examples of
Installation
Dimensions Dimensions
L1 600 600

312.5
L1

312.5

340
290

340
L2 100 100
L2
L3 100 100
103.2

L3

49.6
Unit:mm Unit:mm
49.6

14.6

14
385.9

14
476 2-16x12
136.9 Terminal block
203.1 510 136.9 17.9
850 65 Service panel
Terminal block

B C
Service panel A
C

42.7
B

640
A
640

42.7
42.7

20
20

100.3
20

15
211

20
100.3
15

124.1 34.6
Intake L3
Symbol Content
Symbol Content L2 A Service valve connection gas side 9.52 3 8" Flare
Intake L3
No obstacles B Service valve connection liquid side 6.35 1 4" Flare
L2 A Service valve connection gas side 9.52 3 8" Flare Service space
No obstacles Intake for electrical C Pipe cable draw-out hole
Intake
Service space B Service valve connection liquid side 6.35 1 4" Flare parts
for electrical D Drain discharge hole 20 x 3 places
parts C Pipe cable draw-out hole Outlet L1
E Anchor bolt hole M10 x 4 places
Outlet L1 D Drain discharge hole 20 x 3 places
E Anchor bolt hole M10 x 4 places Minimum installation space
Minimum installation space

Models SCM71ZJ-S1, 80ZJ-S1


SCM71ZJ-S1 SCM80ZJ-S1 SCM100ZJ-S1
Model SCM100ZJ-S1
223 310 60 15 15
2-R7
.5 E 15 E
47.5

Symbol Content
A Service valve connection gas side 9.52 3 8" Flare
Examples of B Service valve connection liquid side 6.35 1 4" Flare
Installation
177
340

380
418

C Pipe cable draw-out hole


Dimensions
Center of gravity D Drain discharge hole 20 x 3places
L1 600 580 26
100 970 73 E Anchor bolt hole M10 x 4places
20

L2
61

L3 100
Unit:mm
19

61
150
D 580 150 26
880 73 Terminal block L3
L2 Intake

52
No obstacles
945

Service space

52
C
Intake

B
for electrical
L1 parts

52
Outlet

531.2
219.2 52 Service

427.2
space
393

A
323.2
115.2 52

Minimum installation space


52
750

Center of gravity
10
52

190 580 200 Terminal block Rear panel


60 76
D
20
40
52

422.4

B
318.4

C
110.4 52

55
214.4

410
370
24

A
40

185 10
20

Intake L3 Symbol Content 262.8 325


L2 A Service valve connection gas side 9.52 3 8" Flare Examples of
No obstacles installation
Service space B Service valve connection liquid side 6.35 1 4" Flare
Intake for electrical Dimensions
C Pipe cable draw-out hole
parts L1 Open Open 500
D Drain discharge hole 20 x 3 places
Outlet L1 L2 300 5 Open
E Anchor bolt hole M10 x 4 places
L3 150 300 150
170 10
Minimum installation space

Model SCM125ZJ-S1
SCM125ZJ-S1
15 15
E Symbol Content
A Service valve connection gas side 9.52 3 8" Flare
B Service valve connection liquid side 6.35 1 4" Flare
C Pipe cable draw-out hole
177

D Drain discharge hole 20 x 3places

580 Center of gravity 26 E Anchor bolt hole M10 x 4places


970 73
52

L3
52

Intake
L2
945

52

No obstacles
Intake Service space
52

635.2

for electrical
531.2

L1 parts
219.2 52

427.2

Outlet
393

Service
323.2

space
115.2 52

Minimum installation space


Center of gravity
10

190 580 200 Terminal block Rear panel


60 76 D
20
40

B
C
55
410
370

A
40
20

262.8 325

Examples of
installation
Dimensions
L1 Open Open 500
MULTI series
300L2Air
5 Conditioners
Open 2013
L3 150 300 150
170 10
27
SPECIFICATIONS
Before starting use
Heating performance Refrigerant leakage
The heating performance values (kW) described in catalog are the values The refrigerant (R410A) used for Air conditioner is non-toxic and nonflammable
obtained by operating at an outdoor temperature of 7C and indoor temperature in its original state.
of 20C as set forth in the ISO Standards. As the heating performance decreases However, in consideration of a state where the refrigerant leaks into the room,
as the outdoor temperature drops, if the outdoor temperature is too low and the measures against refrigerant leaks must be taken in small rooms where the
heating performance is insufficient, use other heating appliances as well. tolerable level could be exceeded. Take measures by installing ventilation
devices, etc.
Indication of sound values
The sound values are the values (A scale) measured in a chamber such as an Use in snowy areas
anechoic chamber following the ISO Standards. In the actual installation state, Take the following measures when installing the outdoor unit in snowy areas.
the value is normally larger than the values given in the catalog due to the effect
of surrounding noise and echo. Take this into consideration when installing.
Snow prevention
Install a snow-prevention hood so that the snow does not obstruct the air intake
Use in oil atmosphere port or enter and freeze in the outdoor unit.
Avoid installing this unit in as atmosphere where oil scatters or builds up, such
as in a kitchen or machine factory.
Snow piling
If the oil adheres to the heat exchanger, the heat exchanging performance will In areas with heavy snow fall, the piled snow could block the air intake port. In
drop, mist may be generated, and the synthetic resin parts may deform and this case, a frame that is 50cm or higher than the estimated snow fall must be
break. installed underneath the outdoor unit.

Use in acidic or alkaline atmosphere Automatic defrosting device


If this unit is used in acidic atmosphere such as hot spring areas having high If the temperature is low, and the humidity is high, frost will stick to the heat
level of sulfuric gases or in alkaline atmosphere including ammonia or calcium exchanger of the outdoor unit. If use is continued, the heating performance will
chloride, places where the exhaust of the heat exchanger is sucked in, or at drop.
coastal areas where the unit is subject to salt breezes, the outer plate or heat The Automatic defrosting device will function to remove this frost.
exchanger, etc., will corrode. Please ask a dealer or specialist when you use an After heating for approx, three to ten minutes, it will stop, and the frost will be
air conditioner in places differing from a general atmosphere. removed. After defrosting, hot air will be blown again.

Use in places with high ceilings Servicing the air-conditioner


If the ceiling is high, install a circulator to improve the heat and air flow After the air-conditioner is used for several seasons, dirt will build up in the
distribution when heating. air-conditioner causing the performance to drop. In addition to regular servicing,
we recommend the maintenance contract (charged for) by a specialist.

Safety Precautions
Air-conditioner usage target Installation
The air-conditioner described in this catalog is a dedicated cooling/heating Always commission the installation to a dealer or specialist. Improper
device for human use. installation will lead to water leakage, electric shocks and fires.
Do not use it for special applications such as the storage of foodstuffs, animals Make sure that the outdoor unit is stable in installation. Fix the unit to stable
or plants, computer server rooms, precision devices or valuable art, etc. base.
This could cause the quality of the items to drop, etc.
Do not use this for cooling vehicles or ships. Water leakage or current leaks
Usage place
could occur. Do not install in places where combustible gas could leak or where there are
sparks.
Before use Installation in a place where combustible gas could be generated, flow or
Always read the User,s Manual thoroughly before starting use. accumulate, or places containing carbon fibers could lead to fires.

Only persons that are qualified and licensed are permitted to install and service products that contain refrigerants in Australia, go to www.arctick.org.
Suitable access for service must be provided in compliance with industry standards and local regulations.

MHIAA is proudly sponsoring


Monikas Doggie Rescue

Australia: New Zealand:


ABN 92 133 980 275 G.S.T. 105-673-620

Phone: 1300 138 007 Fax: 1800 644 329 Phone: 0800 138 007 Fax: 09 442 5346
NSW & Head Office Victoria Queensland Western Australia Auckland
9C Commercial Road 2/24 Lakeside Drive 5/26 Flinders Parade Unit 3A 2 Mulgul Rd Unit 2 100 Bush Road
Kingsgrove NSW 2208 Burwood East North Lakes Malaga WA 6090 Albany 0632
PO Box 318 Kingsgrove VIC 3151 QLD 4509 PO Box 667 Belmont PO Box 300552
NSW 1480 WA 6104 Albany 0632

www.mhiaa.com.au www.mhiaa.co.nz

MRE SPARE PARTS www.mrespareparts.com.au Tel: +61 (0) 2 9600 7444 Fax: +61 (0) 2 9600 8044

ISO9001 ISO14001
Our Air Conditioning & Our Air Conditioning &
Refrigeration Systems Refrigeration Systems
Headquarters is an ISO9001 Headquarters has been ISO 14001
approved factory for residential assessed and found to Certificate 04104 1998 0813 E5
air conditioners and comply with the BIWAJIMA PLANT
BIWAJIMA PLANT MITSUBISHI HEAVY INDUSTRIES- MITSUBISHI HEAVY INDUSTRIES-
commercial-use air Mitsubishi Heavy Industries, Ltd. requirements of Mitsubishi Heavy Industries, Ltd.
MHIAA306_MULTI 12_2012

MAHAJAK AIR CONDITIONERS CO., LTD. Air-conditioning & Refrigeration Systems Headquarters MAHAJAK AIR CONDITIONERS CO.,LTD.
conditioners (including heat Air-conditioning & Refrigeration Systems Headquarters
Certified ISO 9001
Certified ISO 9001
ISO14001. Certified ISO 14001 Certificate Number : 04104 1998 0813 E5
Certificate Number : 04100 1998 0813
pumps). Certificate number : JQA-0709 Certificate number : JQA-EM0256

Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without notice. E&OE.