Instruction ENGLISH

Manual CL3100
Instruction Manual
CL3100 General Specifications
The Klein Tools CL3100 is an auto-function selecting hook meter.
It measures AC / DC voltage, AC current, and resistance. It can also test
ENGLISH continuity.
Operating Altitude: 2000 meters
Relative Humidity: 75% max
Operating Temperature: 0C / 32F to 40C / 104F
Storage Temperature: -10C / 0F to 50C / 122F
BACKLIGHT Accuracy Temperature: 18C / 64F to 28C / 82F
Temperature Coefficient: 0.1*(specified accuracy) / C
WORKLIGHT Sampling Frequency: 2.5 samples per second
600V CAT IV 200A
Jaw Size: 0.5"
MAX / MIN
Dimensions: 10.25" x 2.5" x 1.5"
AUTO FUNCTION Weight: 8.6oz.
SELECT Calibration: Accurate for one year
CL3100 CAT Rating: CAT III 1000V, CAT IV 600V
3-3/4 DIGIT Accuracy: (% of reading + # of least significant digits)
3999 COUNT LCD
WARNINGS
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
MAX/MIN Before each use, verify meter operation by measuring
a known voltage or current.
Never use the meter on a circuit with voltages that exceed the category based
VOLTS: 1.3~750VAC rating of this meter.
2.1~1000VDC
-1.8~-1000VDC Do not use the meter during electrical storms, or in wet weather.
AMPS: 0.9~200 AAC Do not use the meter or test leads if they appear to be damaged.
OHMS: 0 ~40M
Continuity
Ensure meter leads are fully seated, and keep fingers away from
the metal probe contacts when making measurements.
Do not open the meter to replace batteries while the probes
are connected.
For Professionals...Since 1857

V Use caution when working with voltages above 60V DC,


AT or 25V AC RMS. Such voltages pose a shock hazard.
Apo
To avoid false readings that can lead to electrical shock,
replace batteries if a low battery indicator appears.
0 10 20 30 40 Unless measuring voltage or current, shut off and lock out
power before measuring resistance or capacitance.
Always adhere to local and national safety codes. Use individual protective
equipment to prevent shock and arc blast injury where hazardous live
conductors are exposed.

SYMBOLS

~ AC Alternating Current Warning or Caution

DC/AC Voltage or Current Double Insulated Class II

DC Direct Current Ground


Safe for disconnect
AC Source
from live conductors

www.kleintools.com
ENGLISH

Feature Details Where to Measure


A. Measure Voltage, Resistance, and Continuity here
Use leads of proper safety rating only (CAT III / CAT IV).
Do not attempt to measure more than 1000V DC or 750V AC.
Do not attempt to measure current with leads.
B. Measure Current here
Measure up to 200A AC.
Measure when display shows AUTO.
How to Select a Function or Feature
B C. Use to turn instrument ON / OFF, or select MAX / MIN.
Press button for 2 seconds to power on or off.
Press repeatedly to switch between maximum and minimum.
Press button for 2 seconds to return to live reading from MAX/
MIN mode.
D. Access Resistance, Continuity, and Backlight functions here.
Press repeatedly to cycle through AUTO (V / A), resistance,
and continuity modes.
Press for 2 seconds to enable/disable backlight and worklight.
Other Things to Note:
600V CAT IV 200A
E. Magnet and Battery Replacement are on back.
When indicator is displayed on the LCD,
batteries must be replaced.
Turn off device and disconnect leads.
Remove the back screw and replace 2 x AAA batteries.
CL3100
Attach magnet to metal surfaces for hands-free use.
F. Device features Auto Power-Off (Apo)
After 29 minutes non-use, the instrument will beep 3 times.
E
After 1 more minute, the instrument will beep once and power
itself off to conserve battery power.
Holding VA / button while turning on disables Auto Power-Off.
C MAX/MIN

Function Instructions
VOLTS: 1.3~750VAC
2.1~1000VDC 1. Voltage: < 1000 V DC or 750 V AC
-1.8~-1000VDC
AMPS: 0.9~200 AAC
OHMS: 0 ~40M CL3100

Continuity

MAX/MIN

V
VOLTS: 1.3~750VAC
AT 2.1~1000VDC
-1.8~-1000VDC

F
AMPS: 0.9~200 AAC
Apo OHMS: 0 ~40M
Continuity

V
AT

0 10 20 30 40 Apro

0 10 20 30 40

A
ENGLISH

2. Current: < 200A AC Electrical Specifications


DC Voltage Measurement
Range Resolution Accuracy
2.1 ~ 1000V 0.001V ~ 1V
(1.0% + 4 digits)
-1.8 ~ -1000V 0.001V ~ 1V

Overload Protection: 1000V


Input Impedance: > 10M

AC Voltage Measurement
Range Resolution Accuracy
1.3 ~ 750V 0.001V ~ 1V (1.5% + 3 digits)

Incorrect: Overload Protection: 750V RMS


Correct Opposing currents cancel Frequency: 45 to 400Hz
Input Impedance: 10M
3. Resistance / Continuity Response: Averaging

CATIII 400V
PRESS CATIII 400V AC Current Measurement
Range Resolution Accuracy
0.9 ~ 200A 0.1A (2.5% + 8 digits)

Overload Protection: 200A


Frequency: 45 to 400Hz
V/A Response: Averaging

Continuity Continuity Resistance Measurement


Range Resolution Accuracy
V V
AT AT
Apro Apro

0 10 20 30 40 0 10 20 30 40

400 0.1
4k 0.001k
40k 0.01k (1.0% + 4 digits)
400k 0.1k
4M 0.001M
Resistance: < 40M Continuity: Tone below 30 40M 0.01M (2.0% + 4 digits)

Overload Protection: 600V


Symbols used on LCD Continuity Test

~ AC Measurement DC Measurement
Overload Protection Open Circuit Voltage
600V Appx. 0.45V
- Negative DC Value Low Battery
MAX Maximum Reading MIN Minimum Reading
Auto Function
AT Auto Range Active AUTO
Active (V/A)
Overload: Range
O.L. Apo Auto Power-Off Active
Exceeded
V Voltage Measurement A Current in Amps
Resistance in Ohms Continuity Test
m Milli 10-3 k Kilo 103
M Mega 10 6
ENGLISH NOTES

Warranty
This product is warranted to be free from defects in materials and workmanship
for a period of two years from the date of purchase. During this warranty period,
Klein Tools has the option to repair or replace or refund the purchase price of
any unit which fails to conform to this warranty under normal use and service.
This warranty does not cover damage which occurs in shipment or failure which
results from alteration, tampering, accident, misuse, abuse, neglect, or improper
maintenance. Batteries and damage resulting from failed batteries are not
covered by warranty. A purchase receipt or other proof of original purchase date
will be required before warranty repairs will be rendered.
Any implied warranties, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited to the express
warranty. Klein Tools shall not be liable for loss of use of the instrument or other
incidental or consequential damages, expenses, or economic loss, or for any
claim or claims for such damage, expenses or economic loss.
Some states or countries laws vary, so the above limitations or exclusions may
not apply to you. This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state. If your Klein product requires
repair or for information on how to exercise your rights under the terms of this
warranty, please contact Klein Tools at 1-877-775-5346.

CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.

STORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.

Disposal / Recycle
Caution: This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.

CUSTOMER SERVICE

KLEIN TOOLS, INC.


450 Bond Street
Lincolnshire, IL 60069
1-877-775-5346
www.kleintools.com 139549T
Manual de Espaol

Instrucciones CL3100
Manual de Instrucciones
CL3100 ESPECIFICACIONES GENERALEs
El CL3100 de Klein Tools es un medidor de gancho con seleccin de
funcin automtica. Mide tensin de CA / CC, corriente CA y resistencia.
Espaol Tambin puede probar continuidad.
Altitud de funcionamiento: 2000 metros
Humidad relativa: 75% mx
Temperatura de funcionamiento: 0C / 32F a 40C / 104F
Temperatura de almacenamiento: -10C / 0F a 50 C / 122F
Temperatura de precisin: 18C / 64F a 28C / 82F
LUZ DE FONDO Coeficiente de temperatura: 0,1*(precisin especificada) / C
LUZ DE TRABAJO Frecuencia de muestreo: 2,5 muestras por segundo
600V CAT IV 200A Tamao de la mandbula: 0,5 pulgadas
MAX / MIN Dimensiones: 10,25 x 2,5 x 1,5 pulgadas
Peso: 8,6 onzas
SELECCIN DE Calibracin: Precisa durante un ao
FUNCIN AUTO Clasificacin CAT: CAT III 1000V, CAT IV 600V
CL3100
Precisin: (% de la lectura + No. de dgitos menos significativos)
PANTALLA DE LCD DE
3999 CONTEOS CON ADVERTENCIAS
DGITOS DE 3-3/4 Para asegurar un funcionamiento y servicio seguros del probador, siga
estas instrucciones. Si no se hace caso de estas advertencias, el resultado
puede ser lesiones graves o muerte.
MAX/MIN Antes de cada uso, verifique el funcionamiento del multmetro midiendo una
tensin o una corriente conocida.
No utilice nunca el multmetro en un circuito con tensiones que excedan
VOLTS: 1.3~750VAC la capacidad nominal basada en la categora de este multmetro.
2.1~1000VDC
-1.8~-1000VDC No utilice el multmetro durante tormentas elctricas ni en tiempo mojado.
AMPS: 0.9~200 AAC
No utilice el multmetro ni los conductores de prueba si parecen
OHMS: 0 ~40M
estar daados.
Continuity
Asegrese de que los conductores de prueba del multmetro estn
Para Profesionales... Desde 1857

completamente asentados y mantenga los dedos alejados de los contactos


metlicos de los conductores de prueba cuando haga mediciones.
V No abra el multmetro para reemplazar las pilas mientras los conductores de
AT prueba estn conectados.
Apo
Tenga precaucin cuando trabaje con tensiones superiores a 60 V CC,
o 25 V CA de valor eficaz (RMS). Dichas tensiones presentan un peligro
0 10 20 30 40
de descarga.
Para evitar lecturas falsas que pueden llevar a descargas elctricas,
reemplace las pilas si aparece un indicador de pila baja.
A menos que mida tensin o corriente, apague y bloquee el suministro
elctrico antes de medir resistencia o capacitancia.
Cumpla siempre con los cdigos de seguridad locales y nacionales.
Utilice equipo de proteccin individual para evitar las descargas elctricas
y las lesiones por intensas corrientes de arco donde los conductores con
corriente peligrosos estn al descubierto.

SMBOLOS

~ CA Corriente alterna Advertencia o precaucin


Seguro para desconectar de Con aislamiento doble
conductores con corriente de Clase II
CC Corriente continua Conexin a tierra

Tensin o corriente CC/CA Fuente de CA

www.kleintools.com
Espaol

DETALLES DE LAS FUNCIONEs Dnde medir


A. Mida Tensin, Resistencia y Continuidad aqu
Utilice conductores de prueba con un clasificacin de seguridad
apropiada solamente (CAT III / CAT IV).
No intente medir ms de 1000 V CC o 750 CA.
No intente medir corriente con conductores de prueba.
B. Mida Corriente aqu
Mida hasta 200 A CA.
Mida cuando la pantalla muestre AUTO.
Cmo seleccionar una funcin o caracterstica
B C. Utilcela para ENCENDER / APAGAR, el instrumento,
o seleccione MAX / MIN.
Presione el botn durante 2 segundos para encender o
apagar el instrumento.
Presione repetidamente para cambiar entre mximo y mnimo.
Presione el botn durante 2 segundos para regresar a la lectura
en vivo desde el modo MAX/MIN.
D. Acceda a las funciones de Resistencia, Continuidad,
y Luz de fondo aqu.
Presione repetidamente para recorrer en ciclo los modos
CAT IV 200A
AUTO (V / A), resistencia y continuidad.
600V
Presione durante 2 segundos para activar / desactivar la luz de
fondo y la luz de trabajo.
Otras cosas que tener en cuenta:
E. El imn y el reemplazo de las pilas estn en la parte trasera.
CL3100
Cuando el indicador se muestre en la pantalla de LCD,
las pilas deben ser reemplazadas.
Apague el dispositivo y desconecte los conectores de prueba.
Retire el tornillo trasero y reemplace las 2 pilas AAA.
E Sujete el imn a superficies metlicas para permitir el uso con
las manos libres.
F. El dispositivo cuenta con Autoapagado (Apo)
C MAX/MIN Despus de 29 minutos de no utilizarlo, el instrumento
pitar 3 veces.
Despus de 1 minuto ms, el instrumento pitar una vez y se
VOLTS: 1.3~750VAC autoapagar para conservar la energa de las pilas.
2.1~1000VDC
-1.8~-1000VDC Si se mantiene oprimido el botn VA / mientras se enciende
AMPS: 0.9~200 AAC la unidad, se desactiva el autoapagado.
OHMS: 0 ~40M CL3100

Continuity
Instrucciones de las funciones
MAX/MIN

1. Tensin: < 1000 V CC 750 V CA


V
VOLTS: 1.3~750VAC
AT 2.1~1000VDC
-1.8~-1000VDC

F
AMPS: 0.9~200 AAC
Apo OHMS: 0 ~40M
Continuity

V
AT

0 10 20 30 40 Apro

0 10 20 30 40

A
Espaol

2. Corriente: < 200 A CA Especificaciones elctricas


Medicin de tensin de CC
Intervalo Resolucin Precisin
2.1 ~ 1000V 0.001V ~ 1V
(1.0% + 4 dgitos)
-1.8 ~ -1000V 0.001V ~ 1V

Proteccin contra sobrecargas: 1000V


Impedancia de entrada: > 10M

Medicin de tensin de CA
Intervalo Resolucin Precisin
1.3 ~ 750V 0.001V ~ 1V (1.5% + 3 dgitos)

Incorrecto: Proteccin contra sobrecargas: 750V (RMS)


Correcto Las corrientes opuestas se cancelan Frecuencia:: 45 a 400Hz
Impedancia de entrada: 10M
3. Resistencia / Continuidad Respuesta: Promediacin

CATIII
Presionar
400V CATIII 400V Medicin de corriente CA
Intervalo Resolucin Precisin
0.9 ~ 200A 0.1A (2.5% + 8 dgitos)

Proteccin contra sobrecargas: 200A


Frecuencia: 45 a 400Hz
V/A Respuesta: Promediacin

Continuity Continuity Medicin de resistencia


Intervalo Resolucin Precisin
V V
AT AT
Apro Apro

0 10 20 30 40 0 10 20 30 40

400 0.1
4k 0.001k
40k 0.01k (1.0% + 4 dgitos)
400k 0.1k
4M 0.001M
Resistencia: < 40 M Continuidad: 40M 0.01M (2.0% + 4 dgitos)
Tono por debajo de 30
Proteccin contra sobrecargas: 600V

Prueba de continuidad
Smbolos utilizados en la pantalla de LCD
Proteccin contra sobrecargas Tensin del circuito abierto
~ Medicin de CA Medicin de CC 600V Aprox. 0.45V
- Valor de CC negativo Pila baja
MAX Lectura mxima MIN Lectura mnima
Determinacin automtica Funcin Auto activa
AT AUTO
del intervalo activa (V/A)
Sobrecarga:
O.L. Apo Autoapagado activo
Intervalo excedido
V Medicin de tensin A Corriente en A
Resistencia en ohmios Prueba de continuidad
m Mili 10-3 k Kilo 103
M Mega 10 6
Espaol
Mode
Garanta
Se garantiza que este producto estar libre de defectos de materiales y
d'Emploi
CL3100
fabricacin durante un perodo de dos aos a partir de la fecha de compra.
Durante este perodo de garanta, Klein Tools tiene la opcin de reparar,
reemplazar o reembolsar el precio de compra de cualquier unidad que no
cumpla con esta garanta bajo uso y servicio normales. Esta garanta no cubre
los daos que ocurran en el envo o las fallas que ocurran debido a alteracin,
manipulacin indebida, accidente, uso incorrecto, abuso, negligencia o Franais
mantenimiento inapropiado. Las pilas y los daos que ocurran por causa de
pilas que fallen no estn cubiertos por esta garanta. Se requerir un recibo de
compra u otro comprobante de la fecha de compra original antes de que se
realicen las reparaciones bajo garanta.
Todas las garantas implcitas, incluyendo pero sin estar limitadas a las garantas
implcitas de comerciabilidad e idoneidad para un propsito especfico, estn
limitadas a la garanta expresa. Klein Tools no ser responsable por la prdida de
RTROCLAIRAGE
uso del instrumento u otros daos incidentales o emergentes, gastos o prdida
econmica, ni por cualquier reclamo o reclamos por dichos daos, gastos o
LAMPE DE TRAVAIL
600V CAT IV 200A
prdida econmica.
MAX / MIN
Las leyes de algunos estados o pases varan, por lo que es posible que las
limitaciones o exclusiones que anteceden no tengan aplicacin en el caso de
SLECTION
usted. Esta garanta le confiere a usted derechos legales especficos y es posible
que usted tenga tambin otros derechos que varan de un estado a otro. Si su AUTOMATIQUE
CL3100
producto Klein requiere reparacin, o para obtener informacin sobre cmo DE LA FONCTION
ejercer sus derechos bajo los trminos de esta garanta, srvase contactar a
Klein Tools llamando al 1-877-775-5346. 3 3/4 CHIFFRES
LIMPIEZA LCD 3 999 POINTS
Apague el instrumento y desconecte los conductores de prueba. Limpie el
instrumento utilizando un pao hmedo. No utilice limpiadores abrasivos ni MAX/MIN
solventes.

VOLTS: 1.3~750VAC
ALMACENAMIENTO 2.1~1000VDC
-1.8~-1000VDC
Retire las pilas cuando el instrumento no se vaya a usar durante un perodo AMPS: 0.9~200 AAC
prolongado. No lo exponga a altas temperaturas o humedad. Despus de un OHMS: 0 ~40M
Continuity
perodo de almacenamiento en condiciones extremas que excedan los lmites
mencionados en la seccin Especificaciones, deje que el instrumento regrese a
las condiciones de funcionamiento normales antes de utilizarlo.

Pour les Professionnels...Depuis 1857


V
Eliminacin / Reciclaje AT
Apo

Precaucin: Este smbolo indica que el equipo y sus accesorios


estarn sujetos a recogida y desecho correcto por separado. 0 10 20 30 40

SERVICIO AL CLIENTE

KLEIN TOOLS, INC.


450 Bond Street
Lincolnshire, IL 60069
1-877-775-5346
www.kleintools.com 139550T www.kleintools.com
Franais

CL3100 DTAILS DES FONCTIONs

Mode dEmploi
SPCIFICATIONS GNRALEs
L'appareil Klein Tools CL3100 est une pince ampremtrique slection
automatique de la fonction. Il mesure la tension c.a./c.c., le courant c.a.
et la rsistance. Il peut galement tester la continuit des circuits.
Altitude de service : 2 000 mtres
Humidit relative : 75% max
Temprature de service : 0 C / 32F 40 C / 104F
Temprature de stockage : -10C / 0 F 50C / 122F B
Prcision en temprature : 18C / 64F 28C / 82F
Coefficient de temprature : 0,1* (prcision spcifie) / C
Frquence dchantillonnage : 2,5 chantillons par seconde
Taille de la mchoire : 0,5 po
Dimensions : 10,25 po x 2,5 po x 1,5 po
Poids : 8,6 oz
talonnage : Prcis pendant un an
Qualification de cat. : CAT III 1000V, CAT IV 600V
Prcision : (% de lecture + nombre de chiffres les moins significatifs)
600V CAT IV 200A
AVERTISSEMENTS
Pour assurer un fonctionnement et un service sans danger du testeur,
suivez les instructions ci-aprs.Le non-respect des ces avertissements
risquerait de causer des blessures graves ou mme la mort :
Avant chaque emploi, vrifiez le fonctionnement de lappareil de mesure
en mesurant une tension ou un courant connu. CL3100
Nutilisez jamais cet appareil de mesure sur un circuit dont la tension
dpasse la qualification de catgorie de cet appareil de mesure.
Nutilisez pas cet appareil de mesure pendant un orage lectrique ou par
temps humide. E
Nutilisez pas lappareil de mesure ou les fils dessai sils semblent tre
endommags.
Assurez-vous que les fils de connexion de lappareil de mesure sont bien
leur place, et gardez les doigts distance des contacts de la sonde en mtal C MAX/MIN
lorsque vous effectuez des mesures.
Nouvrez pas lappareil de mesure pour remplacer des piles pendant que les
sondes sont toujours connectes. VOLTS: 1.3~750VAC
Prenez des prcautions lorsque vous travaillez avec des tensions de plus de 2.1~1000VDC
-1.8~-1000VDC
60 V c.c. ou 25 V c.a. eff. De telles tensions prsentent un risque de choc AMPS: 0.9~200 AAC
lectrique. OHMS: 0 ~40M
Pour viter des lectures errones qui pourraient causer un choc lectrique, Continuity
remplacez les piles si un voyant de dcharge partielle des piles sallume.
Sauf si vous tes en train de mesurer une tension ou un courant, mettez
lappareil hors circuit et verrouillez-le avant de mesurer une rsistance ou
une capacit. V
Respectez toujours les dispositions des codes de scurit national et local. AT

Utilisez des quipements de protection individuelle pour viter tout risque F Apo

de choc lectrique ou de blessure cause par une explosion lectrique


lorsque des conducteurs sous tension dangereux sont exposs. 0 10 20 30 40

SYMBOLES
D
~ Courant alternatif c.a. Avertissement ou Mise en garde
Courant continu c.c. Tension ou courant c.c./c.a
Masse Classe II, double isolation
Sans danger pour la dconnexion
Source c.a. A
de conducteurs sous tension
Franais

O mesurer 2. Intensit du courant : < 200 A c.a.


A. Mesurez la tension, la rsistance et la continuit ici
Utilisez seulement des conducteurs de catgorie approprie
(CAT III / CAT IV) en terme de scurit.
Ne tentez pas de mesurer plus de 1 000 V c.c. ou 750 V c.a.
Ne tentez pas de mesurer du courant avec les conducteurs.
B. Mesurez le Courant ici
Mesurez jusqu 200 A c.a.
Mesurez lorsque lcran affiche AUTO.
Comment slectionner une fonction ou une fonctionnalit
C. Utilisez pour allumer / teindre (ON / OFF),
linstrument ou pour slectionner MAX / MIN.
Appuyez sur le bouton et maintenez-le enfonc pendant deux
Incorrect :
secondes pour allumer ou pour teindre lappareil. Correct Les courants contraires sannulent.
Appuyez de faon rpte pour alterner entre maximum et minimum.
Appuyez sur le bouton pendant deux secondes pour retourner 3. Rsistance / Continuit
la valeur actuelle depuis le mode MAX/MIN.
D. Accdez aux fonctions Rsistance, Continuit et Rtroclairage ici.
CATIII 400V
Appuyez CATIII 400V

Appuyez de faon rpte pour faire dfiler les modes


AUTO (V / A), rsistance et continuit.
Appuyez et maintenez enfonc pendant deux secondes pour
activer/dsactiver le rtroclairage et la lampe de travail.
Autres choses noter : V/A
E. Aimant et Remplacement des piles sont larrire. Continuity Continuity

Lorsque le voyant est affich sur lcran ACL, cela signifie AT


V
AT
V

quil faut changer les piles.


Apro Apro

0 10 20 30 40 0 10 20 30 40

teignez lappareil et dconnectez les conducteurs.


Retirez la vis arrire, et remplacez les 2 piles AAA.
Attachez laimant une surface en mtal afin davoir les mains libres.
F. Lappareil a une fonction de Mise hors tension automatique
(Auto Power-Off (Apo)
Au bout de 29 minutes dinutilisation, lappareil mettra trois bips
en succession. Rsistance : < 40 M Continuit :
Tonalit au-dessous de 30
Une minute plus tard, lappareil mettra un bip de plus et se mettra
automatiquement hors tension afin de conserver lnergie des piles.
Le maintien du bouton VA / en position enfonce pendant la mise
Symboles utiliss sur l'cran ACL
en service de lappareil dsactive la fonction de mise hors tension
automatique.
CL3100
~ Mesure c.a Mesure c.c.
- Valeur c.c. ngative Dcharge partielle des piles
Instructions relatives aux fonctions
MAX/MIN
MAX Lecture maximum MIN Lecture minimum
1. Tension : < 1 000 V c.c. ou 750 V c.a.
VOLTS: 1.3~750VAC
Plage automatique
AT AUTO
2.1~1000VDC
-1.8~-1000VDC
AMPS: 0.9~200 AAC
Fonction Auto active (V/A)
OHMS: 0 ~40M
Continuity active
V
Surcharge : Limite Fonction de Mise hors tension
O.L. Apo
AT
Apro

0 10 20 30 40
de plage dpasse automatiquement active
V Mesure de la tension A Courant en ampres
Rsistance en Ohms Test de continuit
m Milli 10-3 k Kilo 103
M Mga 10 6
Franais

Spcifications lectriques Garantie


Mesure de la tension c.c. Ce produit est garanti sans dfauts de matriau ou de fabrication pendant une
priode de deux ans compter de la date de lachat. Pendant cette priode de
Plage Rsolution Prcision garantie, son choix, Klein rparera ou remplacera tout produit qui ne serait
2.1 ~ 1000V 0.001V ~ 1V pas conforme cette garantie dans des conditions normales dutilisation et de
(1.0% + 4 chiffres) service, ou en remboursera le prix dachat. Cette garantie ne couvre pas les
-1.8 ~ -1000V 0.001V ~ 1V dommages qui surviennent pendant lexpdition ou les dfaillances qui rsultent
dune altration, dune falsification, dun accident, dune utilisation non conforme
Protection contre les surcharges : 1000V
ou abusive, de ngligence ou dune maintenance incorrecte. Les piles et les
Impdance d'entre : > 10M
dommages rsultant de piles dfectueuses ne sont pas couverts par la garantie.
Mesure de la tension c.a. Un reu dachat ou un autre justificatif indiquant la date de lachat initial sera
exig avant que des rparations ne soient effectues dans le cadre de la garantie.
Plage Rsolution Prcision
Toutes garanties implicites, y compris, entre autres, les garanties implicites
1.3 ~ 750V 0.001V ~ 1V (1.5% + 3 chiffres) de qualit marchande et dadquation un but particulier, sont limites la
garantie expresse. Klein Tools nassumera aucune responsabilit au titre de la
Protection contre les surcharges : 750V eff. perte dutilisation de linstrument ou pour dautres dommages, frais ou pertes
Frquence : 45 400Hz conomiques secondaires ou accessoires, ou en cas de rclamation ou de
Impdance d'entre : 10M rclamations pour de tels dommages, frais ou pertes conomiques.
Rponse : Prquation tant donn que les lois de certains tats, de certaines provinces ou de certains
pays varient, les limitations ou exclusions ci-dessus ne sappliquent peut-tre
Mesure du courant c.a. pas vous. Cette garantie vous confre des droits particuliers, et vous pouvez
Plage Rsolution Prcision aussi avoir dautres droits qui varient selon ltat ou la province o vous rsidez.
Si votre produit Klein ncessite des rparations ou pour connatre la faon
0.9 ~ 200A 0.1A (2.5% + 8 chiffres) de faire valoir vos droits en vertu des termes de la prsente garantie, veuillez
contacter Klein Tools au 1-877-775-5346
Protection contre les surcharges : 200A
Frquence : 45 400Hz NETTOYAGE
Rponse : Prquation
teignez l'instrument et dconnectez les fils de test. Nettoyez l'instrument en
Mesure de la rsistance utilisant un tissu humide. Nutilisez pas de solvants ou de produits de nettoyage
abrasifs.
Plage Rsolution Prcision
400 0.1 RANGEMENT
4k 0.001k Retirez les piles lorsque l'instrument ne va pas tre utilis pendant une priode
40k 0.01k (1.0% + 4 chiffres) prolonge. N'exposez pas une temprature ou une humidit leve. la suite
d'une priode de rangement dans des conditions extrmes dpassant les limites
400k 0.1k
mentionnes dans la section consacre aux spcifications, laissez l'instrument
4M 0.001M retourner dans des conditions de mesure normales avant de vous en servir
40M 0.01M (2.0% + 4 chiffres) nouveau.

Protection contre les surcharges : 600V Mise au rebut/recyclage


Test de continuit Mise en garde: Ce symbole indique que l'quipement et ses
accessoires doivent faire l'objet d'une limination distincte et d'une
Protection contre les surcharges Tension de circuit ouvert mise au rebut conforme aux rglements.
600V Appx. 0.45V

SERVICE LA CLIENTLE

KLEIN TOOLS, INC.


450 Bond Street
Lincolnshire, IL 60069
1-877-775-5346
www.kleintools.com 139551T