You are on page 1of 5

SL 1m cube 43.3*.3=14.313 per kg .

3kg

MAXIMUM
SYSTEM COATING NO OF COATING SERVICE APPROVED BRAND
TEMPERATURE

One Coat 65-100 micrometers, Two or more coats


Epoxy Coating System for Atmospheric
1 APCS 1A 150 micrometers, Three coats 275-400 150C
Service (with Inorganic Zinc Primer)
micrometers

One Coat 50-100 micrometers, Two or more coats


Epoxy Coating System for Atmospheric
2 APCS 1B 150 micrometers, Three coats 275-400 150C
Service (with Epoxy Primer)
micrometers

One Coat 40-75 micrometers, Two or more coats


Epoxy Coating System for Atmospheric
3 APCS 1C 150 micrometers, Three coats 250-375 150C
Service (with Zinc-Rich Epoxy Primer)
micrometers

Epoxy/Polyurethane Coating System for One Coat 65-100 micrometers, Two or more coats
4 APCS 1D Atmospheric Service (with Inorganic 25-65 micrometers, Three coats 190-315 80C
Zinc Primer) micrometers

Epoxy/Polyurethane Coating System for


One Coat 50-100 micrometers, Two or more coats
5 APCS 1E Atmospheric Service (with Inorganic 80C
100-150 meters, Three coats 175-315 micrometers
Zinc Primer)

Epoxy/Polyurethane Coating System for


One Coat 40-75 micrometers, Two or more coats
6 APCS 1F Atmospheric Service (with Inorganic 80C
125-175 meters, Three coats 190-315 micrometers
Zinc Primer)

Phenolic Epoxy Coating System for One Coat 40-65 micrometers, Two or more coats
7 APCS 2A 90C
Immersion Service (Self-Priming). 125 meters, Three coats 275-375 micrometers

Epoxy Coating System for Potable One Coat 40-65 micrometers, Two or more coats
8 APCS 2B 90C
Water Immersion Service (Self-Priming) 125 meters, Three coats 275-375 micrometers

Epoxy Coating System for Immersion One Coat 00 micrometers, Two or more coats 125
9 APCS 2C 120C
Service, at Temperatures up to 120C meters, Three coats 275-375 micrometers

Epoxy Coating System for Interior of


One Coat 125 micrometers, Minimum two coats
10 APCS 2D Steel Aviation Fuel Storage Tanks and 90C
200-250 meters
Piping

Solvent Free Epoxy Coating for


Minimum one coat 500 600 micrometers,
11 APCS 2E Immersion Service at Temperature up to 93C
93C minimum-maximum.

Glass Flake Reinforced Polyester


Minimum one coat 600 1000 micrometers,
12 APCS 2F Coating for Immersion Service at 100C
temperature up to 93C minimum-maximum.

Glass Flake Reinforced Vinyl Ester


One Coat 600-1000 micrometers, minimum-
13 APCS 2G Coating for Immersion Service at 90C
Temperature up to 90C maximum

100% Solid, Glass Flake Epoxy Coating


14 APCS 2H One Coat 30-40 mils 105C
for Immersion Service up to 105C

Ceramic/Inorganic Filled Epoxy-


15 APCS 2I Phenolic/Novolac Coating for 20-40 mils 150C
Immersion Service up to 150C
Coal Tar Epoxy Coating System for Two or more coats 300 micrometers, maximum per
16 APCS 3 Immersion & Buried for Steel and coat Minimum two coats 400-600 micrometers, 70C
Concrete minimum-maximum
Primer:Two or more coats 50 , maximum per coat
75 micrometers, minimum primer total
Aluminum-Pigmented Alkyd Coating Topcoats: One or more coats 40 micrometers,
17 APCS 4 80C
System maximum per coat
Total System: Minimum three coats 115-180
micrometers, minimum-maximum

18 APCS 5A Heat Radiant Insulating Coating 40-65 micrometers, minimum - maximum 350C

40-65 micrometers, minimum - maximum, Hot


19 APCS 5B Hot Insulating Coating Insulating Coating18 (450 microns) to 22 mils (550 500C
microns)

Primer:Two or more coats 50 , maximum per coat


75 micrometers, minimum primer total
Topcoats: One or more coats 50 micrometers,
20 APCS 6 Alkyd Enamel Coating System 70C
maximum per coat
Total System: Minimum three coats 125-200
micrometers, minimum-maximum

Topcoats: One or more coats


40 micrometers (1.5 mils) maximum per coat for
aluminum alkyds
50 micrometers (2.0 mils) maximum per coat for
Rust Conversion Primer/Alkyd Topcoat alkyd enamels.
21 APCS 7 70C
System for Use on Slightly Rusted Steel Total System: Minimum three coats.
Alkyd enamels: 50-100 micrometers (2-4 mils)
above the thickness of the rust converter.
Aluminum alkyds: 37-75 micrometers (1- to 3
mils) above the thickness of the rust converter.

Primer: One or more coats 50-75 micrometers,


22 APCS 9 Chlorinated Rubber Coating System 60C
minimum-maximum

Primer: One or more coats 50-75 micrometers,


minimum-maximum
Bituminous Paint for Moderate
Topcoat: One or more coats 50-100 micrometers,
23 APCS 10 Temperature, Buried or Immersion 60C
minimum-maximum
Service (Self-Priming)
Total System: Minimum two coats 100-175
micrometers, minimum-maximum

Primer: One coat 25-65 micrometers, minimum-


maximum
High Temperature Coating System for
Topcoat(s): One coat 15-40 micrometers,
24 APCS 11A Atmospheric Service between 150C- 150C-400C
minimum-maximum
400C (with Inorganic Zinc Primer).
Total System: Two coats 40-105 micrometers,
minimum-maximum

Primer: One coat 15-40 micrometers, minimum-


maximum
Very High Temperature Coating System
Topcoat: One coat 15-40 micrometers, minimum-
25 APCS 11B for Atmospheric Service between 400C 400C-540C
maximum
- 540C
Total System: Two coats 30-80 micrometers,
minimum-maximum

System 1: Ambient Steel Application


First Coat: 5-6 mils (125-150 microns)
Second Coat: 5-6 mils (125-150 microns)
Total Dry Film Thickness: 10-12 mils (250-300
Air-Drying, Single Component, High
microns)
Heat External Coating for Bare and
26 APCS 11C System 2: Hot Steel Application (300-500F) 1500F
Insulated Carbon Steel & Austenitic
First Coat: 5-6 mils (125-150 microns)
Stainless at Service
Second Coat: 5-6 mils (125-150 microns)
Third Coat: 5-6 mils (125-150 microns)
Total Dry Film Thickness: 15-18 mils (375-450
microns)
Primer: One or more coats 50-100 micrometers,
minimum-maximum
Topcoats: Two or more coats 150 micrometers,
maximum per coat
Non-Skid Epoxy Coating System for
27 APCS 12 Nonskid aggregate shall be broadcast into the next 150C
Floors and Decks
to last topcoat while it is still wet. A final topcoat
shall be applied over the aggregate sealing it in.
Total System: Minimum three coats 275-400
micrometers, minimum-maximum

28 APCS 17A Inorganic Zinc Primer, Solvent Based One coat 65-100 micrometers, minimum-maximum 400C

29 APCS 17B Inorganic Zinc Primer, Water Based One coat 65-100 micrometers, minimum-maximum 400C

30 APCS 19A Splash Zone Compound, Hand Applied One coat 2500 micrometers, minimum-maximum 80C

31 APCS 19B Splash Zone Compound, Spray Applied One coat 2500 micrometers, minimum-maximum 80C

New Construction: Two coats @ 750 microns per


Glass Flake Reinforced Polyester/
coat and total of 1500 microns
32 APCS 19C Epoxy Coating Systems for Offshore 93C
Maintenance Coating for Existing Structures: One
Structural Steel at Splash Zone
Coat @ 750 1000 microns

Fiberglass Reinforced Coatings, Hand Varies with resin


33 APCS 20A As recommended by the Coating Manufacturer.
Lay-Up used.

Chopped Fiberglass Reinforced Epoxy Varies with resin


34 APCS 20B As recommended by the Coating Manufacturer.
Coatings, Spray Applied used.

Each Coat: Two or more coats 200 micrometers,


(Epoxy Coating for Application onto
maximum per coat
35 APCS 22A Damp Steel Surfaces; Two-Coat 150C
Total System: Minimum two coats 300-400
System)
micrometers, minimum-maximum

(Epoxy Coating for Application onto One coat


36 APCS 22B Damp Steel Surfaces; One-Coat 350-500 micrometers for atmospheric service 150C
System) 400-575 micrometers for splash zone service

Dry Film Thickness Requirements


High Temperature Mastic Paint for Each Coat: See Saudi Aramco data sheets
37 APCS 23 Buried or Immersion Service (Self- (SAES-H-101V) for dry film thickness per coat and 95C.
Priming) number of coats.
Total System: 500 micrometers, minimum

Dry Film Thickness Requirements


For Maintenance over Existing Sound Coating
Each Coat: One or more coats 125-200
SAES-H-001:Coating
micrometers, minimum-maximum
thickness within 2 m of
Total System: Minimum one coat 125-200
anode connections shall
38 APCS 26 Epoxy Mastic Coating (Self-Priming) micrometers minimum-maximum (above the 120C
be 30% greater than the
thickness of any existing coating).
specified dry film
For New Construction
thickness range.
Each Coat Two or more coats 150 200 microns,
minimum - maximum
Total System: 300 400 microns
Dry Film Thickness Requirements
For Maintenance over Existing Sound Coating
Each Coat
Primer: One or more coats 125-200 micrometers,
minimum-maximum
Topcoat: One coat 25-65 micrometers
Total system: Minimum two coats, 150-260
Epoxy Mastic/Polyurethane Coating micrometers, minimum-maximum above the
39 APCS 26T 80C
System thickness of any existing coating.For New
Construction
Primer: Two or more coats 250 300 microns,
minimum-maximum
Topcoat One coat 40 60 microns, minimum-
maximum
Total System: 290-360 microns minimum-
maximum

Application and Dry Film Thickness Requirements


Application: Single coat application by airless
equipment (45:1) to build up the required thickness
Stripe Coating: Weld lines, appurtenances, welded
Solvent Free Two-component Ultra
brackets, nozzles, and corners should be stripe Not suitable for
Hybrid Epoxy Coating System for
40 APCS 27 coated prior to spray apply the coating. Use Hand potable water
Immersion Service at Temperature up to
brushing grade to wet out surfaces. services.
150C
Total Thickness: For Amines and Other Chemicals:
One or two coats; 600 - 1000 microns
For Gas, Crude Oil and Water: One coat; 400 - 600
microns

Dry Film Thickness Requirements


For use as maintenance coating
Priming: All clean blasted surfaces shall be primed
with a primer grade of the product used. The
primer shall wet out all blasted surfaces
immediately after blasting.
Filling: Pits and worn out sections shall be repaired
using the filler grade of the product used or any
Specialty Coating Systems for Pumps,
approved compatible filler. Suitable up to
41 APCS 28 Valves, Piping Fitting and Exchanger
Build main Coats: One or more coats of the 105C .
Boxes
product used 500-1000 microns, minimum-
maximum.
Topcoat: One coat 250 - 300 microns, minimum -
maximum
(for smoothness & non-stick)
For new Pumps and Valves
Total coating film thickness between 750 1500
microns.

Signature & Date