You are on page 1of 5

MTL-20160318

MATERIALS

1. PLATES
THICKNESS (mm) ORDER SIZE USAGE SPECIFICATION
4.0 1500mm (W) x 6000mm (L) Webs of built-up sections
5.0 1500mm (W) x 6000mm (L) Webs and Flanges of built-up sections
6.0
1500mm (W) x 6000mm (L) Webs and Flanges of built-up sections GB/T 1591 G345B
8.0
Fy = 34.5 kN/cm
10.0 Webs and Flanges of built-up sections,
2100mm (W) x 6000mm (L) Fu = 47.0 kN/cm
12.0 Connection plates
15.0
20.0 2100mm (W) x 6000mm (L) Flanges of built-up sections, Connection Plates
25.0

2. COLD-FORMED SECTIONS

TYPE SECTIONS ORDER LENGTH USAGE SPECIFICATION


150Z12 COIL 1.20mm x 295mm W
Purlins, Girts & Eave Struts
150Z15 COIL 1.50mm x 295mm W
@Bay spacing = 6m or less than
150Z17 COIL 1.70mm x 295mm W
200Z15 COIL 1.50mm x 365mm W
200Z17 COIL 1.70mm x 365mm W
Purlins, Girts & Eave Struts
200Z20 COIL 2.00mm x 365mm W
200Z23 COIL 2.30mm x 365mm W JIS G3302
SGH G350
BLACK COIL

250Z17 COIL 1.70mm x 425mm W Purlins, Girts & Eave Struts


250Z20 COIL 2.00mm x 425mm W @Bay spacing = 10m or greater (For Red Oxide- Primed)
250Z23 COIL 2.30mm x 425mm W than
Fy = 35.0 kN/cm
150C20 COIL 2.00mm x 295mm W Fu = 45.0 kN/cm
150C23 COIL 2.30mm x 295mm W
200C20 COIL 2.00mm x 365mm W End Wall Rafters, Frame Openings,
200C23 COIL 2.30mm x 365mm W Eave Struts, Wind Columns
250C20 COIL 2.00mm x 425mm W & Mezzanine Joists

250C23 COIL 2.30mm x 425mm W


300C20 COIL 2.00mm x 465mm W

Issued: 07/10/2015 PAGE 1


2. COLD-FORMED SECTIONS (Continued)
TYPE SECTIONS ORDER LENGTH USAGE SPECIFICATION
150Z12 COIL 1.20mm x 295mm W
Purlins, Girts & Eave Struts
150Z15 COIL 1.50mm x 295mm W
@Bay spacing = 6m or less than
150Z17 COIL 1.70mm x 295mm W
200Z15 COIL 1.50mm x 365mm W
200Z17 COIL 1.70mm x 365mm W
Purlins, Girts & Eave Struts
200Z20 COIL 2.00mm x 365mm W
200Z23 COIL 2.30mm x 365mm W JIS G3302
SGCC G450
GALVANIZED

250Z17 COIL 1.70mm x 425mm W


Purlins, Girts & Eave Struts
250Z20 COIL 2.00mm x 425mm W (For Galvanized)
@Bay spacing = 10m or greater than
250Z23 COIL 2.30mm x 425mm W
Fy = 45.0 kN/cm
150C20 COIL 2.00mm x 295mm W Fu = 51.0 kN/cm
150C23 COIL 2.30mm x 295mm W
200C20 COIL 2.00mm x 365mm W End Wall Rafters, Frame Openings,
200C23 COIL 2.30mm x 365mm W Eave Struts & Wind Columns
250C20 COIL 2.00mm x 425mm W
250C23 COIL 2.30mm x 425mm W
75C20 COIL 2.00mm x 170mm W Slide Door Guide

3. HOT-ROLLED SECTIONS
TYPE ORDER SIZE USAGE SPECIFICATION
IPE200A x 12m Eave Extension

IPE200 x 12m
Wind Columns, End-wall Rafters & JIS-G3101 SS400
IPE250 x 12m
I SECTIONS Mezzanine Joists Fy = 23.5 kN/cm
IPE300 x 12m
Fu = 40.0 kN/cm
IPE350 x 12m
Crane Runway Beams
IPE400 x 12m

EN 10025 - S235
CHANNEL UE 250mm x 78mm x 8mm x 12m Stringer for Staircase Fy = 23.5 kN/cm
Fu = 36.0 kN/cm

40mm x 40mm x 4mm x 6m


50mm x 50mm x 5mm x 6m JIS-G3101 SS400
Flange Bracing, X Bracing and Open Web
ANGLES Fy = 23.5 kN/cm
75mm x 75mm x 6mm x 6m Joist Member
Fu = 40.0 kN/cm
100mm x 100mm x 8mm x 6m
42mm x 2.3mm x 6m Hand Rails/Space Frame Diagonal Members
JIS G3302 SGH400
PIPE
49mm x 2.7mm x 6m Space Frame Fy = 29.5 kN/cm
Galvanized
90mm x 2.7mm x 6m Diagonal Members Fu = 40.0 kN/cm

Issued: 07/10/2015 PAGE 2


4. SHEETING
PANEL TYPE THICKNESS ORDER SIZE USAGE SPECIFICATION
0.40mm Sheeting Panels for Walls, Liners &
Coil
I-TRIM 1000-7 (7-Rib) 0.45mm Partitions, Eave Extensions, Roof Monitors,
1200mm W Canopies, Soffit & Sliding Door Liners
0.50mm
0.40mm
Coil
I-TRIM 1000-5 (Hi-Rib) 0.45mm Sheeting Panels for Roof & Walls AS 1397
1200mm W
0.50mm G300
0.40mm Coating AZ100
Coil Sheeting Panel for Roof, available with
I-CAP 980 (5-Rib) 0.45mm Fy = 30.0 kN/cm
1200mm W PU20mm, PU30mm & PU40mm
0.50mm
0.45mm Coil
I-SEAM 460 (Deep-Rib) Sheeting Panel for Roof
0.50mm 600mm W
0.60mm JIS G3302
0.80mm Coil SGC340
I-DECK 1000 Sheeting Panel for Mezzanine Deck
1.00mm 1219mm W Fy = 24.5 kN/cm
1.20mm Fu = 34.0 kN/cm

5. SKYLIGHT PANELS
PANEL TYPE THICKNESS ORDER LENGTH USAGE SPECIFICATION
SKYLITE1000 (5-Rib)
SKYLITE1000 (7-Rib) Translucent Panels for Roof,
1.2mm 5500mm
Walls
SKYLITE980 (5-Rib)
SKYLITE460 1.2mm 5500mm Translucent Panels for Roof

6. TRIMS
TYPE COLOR MAXIMUM ORDER SIZE SPECIFICATION
AS 1397 G300
Trims & Flashing All Standard Colors COIL 0.5mm T x 600mm W Coating AZ100
Fy = 30.0 kN/cm

AS 1397 G300
All Standard Colors COIL 0.5mm T x 1210mm W Coating AZ100
Gutters
Valley Gutters Fy = 30.0 kN/cm

Stainless Steel COIL 0.6mm T x 1219mm W Stainless Steel SS304

7. INSULATION
TYPE ORDER SIZE USAGE SPECIFICATION
Air Bubble 3mm x 1240mm x 100m L Insulation in Roof & Walls (Single Skin)
50mm x 1200mm x 10m L (24kg/m3)
Fiberglass 50mm x 1200mm x 7.5m L Insulation in Roof & Walls (Double Skin)
(32kg/m3)
50mm x 600mm x 1.2mm (40kg/m3)
Rockwool 50mm x 600mm x 1.2mm (50kg/m3) Insulation in Roof & Walls (Double Skin)
(1 package = 6pcs)
20mm T Insulation Attached in I-CAP 980
Polyurethane Foam (PU) 30mm T Double Skin with Aluminum Foil
40mm T Or Back Panel

Issued: 07/10/2015 PAGE 3


8. RODS
ROD DIAMETER ORDER LENGTH USAGE SPECIFICATION
ASTM A36M
12mm 1.5m Sag Rods Fy = 25.0 kN/cm
Fu = 40.0 kN/cm

9. CABLE BRACING

STRAND DIAMETER ORDER DESCRIPTION USAGE SPECIFICATION


Zinc Coated, 7-Wire Strand GB/T 20118
15mm 6 wire Layer Eccentrically twisted over one High Strength
center Wire Coil Cable Bracing Breaking Load = 117.5 kN
M 24 Eye Bolt in
Roof and Walls
Additional Items: Wire Rope Thimble 15mm Class 4.6 Electro-Galvanized
Wire Rope Clamp 15mm

10. ANCHOR BOLTS


DIAMETER (mm) ORDER LENGTH USAGE SPECIFICATION
M16 400mm Anchor bolts for End-wall & Partition Column Bases
M20 500mm ASTM A36M
Anchor Bolts for Main Frame, Endwall Fy = 25.0 kN/cm
M24 600mm
& Mezzanine Column Bases Fu = 40.0 kN/cm
M30 900mm

11. BOLTS
DIAMETER (mm) ORDER LENGTH USAGE SPECIFICATION
DIN 558 GRADE 4.8
Secondary Connections
M12 30mm Fy = 32.0 kN/cm
Purlins & Girts
Fu = 40.0 kN/cm
Eave Strut
M12 35mm
Frame Connections
M16 50mm ASTM A325M
60mm Fy = 56.0 kN/cm
M20 Connections of Primary Sections
70mm Fu = 72.5 kN/cm
Other Moment Connections
M24 90mm
M27 100mm

12. NUTS
NUT DIAMETER (mm) USAGE SPECIFICATION
M12 Secondary Connections - Machine Bolts DIN 934 Class 5
M16
For Anchor Bolts DIN 934 Class 5
M20
Electro Galvanized
M24 For Cable Bracing & Anchor Bolt Hexagon Nuts
M30 For Anchor Bolts

Issued: 07/10/2015 PAGE 4


12. NUTS (Continued)
NUT DIAMETER (mm) USAGE SPECIFICATION
M12 DIN 934 Class8 HDG
M16
High Strength Nut for
M20 ASTM A563M
Main Connections
M24 HDG Hexagonal Nut

M27

13. WASHERS
WASHER DIAMETER (mm) USAGE SPECIFICATION
M16
For Anchor Bolts DIN 125 Type A
M20
Flat Mild Electro-
M24 For Anchor Bolts and Cable Bracing Galvanized
M30 For Anchor Bolts
M12
M16
For High Strength Bolt of ASTM F436 Type 1
M20
Main Connections Round Hard
M24
M27
ASTM A48M Class 275B
M24 Bracing System HDG (Hill Side Washer)

14. SHEAR STUDS


STUD DIAMETER (mm) ORDER LENGTH USAGE SPECIFICATION
GB 10433 ML15AL
Composite Connection for Steel Structural
M19 95mm Fy = 32.0 kN/cm
Members
Fu = 40.0 kN/cm

Issued: 07/10/2015 PAGE 5