MATERIALS
1. PLATES
THICKNESS (mm) ORDER SIZE USAGE SPECIFICATION
4.0 1500mm (W) x 6000mm (L) Webs of built-up sections
5.0 1500mm (W) x 6000mm (L) Webs and Flanges of built-up sections
6.0
1500mm (W) x 6000mm (L) Webs and Flanges of built-up sections GB/T 1591 G345B
8.0
Fy = 34.5 kN/cm
10.0 Webs and Flanges of built-up sections,
2100mm (W) x 6000mm (L) Fu = 47.0 kN/cm
12.0 Connection plates
15.0
20.0 2100mm (W) x 6000mm (L) Flanges of built-up sections, Connection Plates
25.0
2. COLD-FORMED SECTIONS
3. HOT-ROLLED SECTIONS
TYPE ORDER SIZE USAGE SPECIFICATION
IPE200A x 12m Eave Extension
IPE200 x 12m
Wind Columns, End-wall Rafters & JIS-G3101 SS400
IPE250 x 12m
I SECTIONS Mezzanine Joists Fy = 23.5 kN/cm
IPE300 x 12m
Fu = 40.0 kN/cm
IPE350 x 12m
Crane Runway Beams
IPE400 x 12m
EN 10025 - S235
CHANNEL UE 250mm x 78mm x 8mm x 12m Stringer for Staircase Fy = 23.5 kN/cm
Fu = 36.0 kN/cm
5. SKYLIGHT PANELS
PANEL TYPE THICKNESS ORDER LENGTH USAGE SPECIFICATION
SKYLITE1000 (5-Rib)
SKYLITE1000 (7-Rib) Translucent Panels for Roof,
1.2mm 5500mm
Walls
SKYLITE980 (5-Rib)
SKYLITE460 1.2mm 5500mm Translucent Panels for Roof
6. TRIMS
TYPE COLOR MAXIMUM ORDER SIZE SPECIFICATION
AS 1397 G300
Trims & Flashing All Standard Colors COIL 0.5mm T x 600mm W Coating AZ100
Fy = 30.0 kN/cm
AS 1397 G300
All Standard Colors COIL 0.5mm T x 1210mm W Coating AZ100
Gutters
Valley Gutters Fy = 30.0 kN/cm
7. INSULATION
TYPE ORDER SIZE USAGE SPECIFICATION
Air Bubble 3mm x 1240mm x 100m L Insulation in Roof & Walls (Single Skin)
50mm x 1200mm x 10m L (24kg/m3)
Fiberglass 50mm x 1200mm x 7.5m L Insulation in Roof & Walls (Double Skin)
(32kg/m3)
50mm x 600mm x 1.2mm (40kg/m3)
Rockwool 50mm x 600mm x 1.2mm (50kg/m3) Insulation in Roof & Walls (Double Skin)
(1 package = 6pcs)
20mm T Insulation Attached in I-CAP 980
Polyurethane Foam (PU) 30mm T Double Skin with Aluminum Foil
40mm T Or Back Panel
9. CABLE BRACING
11. BOLTS
DIAMETER (mm) ORDER LENGTH USAGE SPECIFICATION
DIN 558 GRADE 4.8
Secondary Connections
M12 30mm Fy = 32.0 kN/cm
Purlins & Girts
Fu = 40.0 kN/cm
Eave Strut
M12 35mm
Frame Connections
M16 50mm ASTM A325M
60mm Fy = 56.0 kN/cm
M20 Connections of Primary Sections
70mm Fu = 72.5 kN/cm
Other Moment Connections
M24 90mm
M27 100mm
12. NUTS
NUT DIAMETER (mm) USAGE SPECIFICATION
M12 Secondary Connections - Machine Bolts DIN 934 Class 5
M16
For Anchor Bolts DIN 934 Class 5
M20
Electro Galvanized
M24 For Cable Bracing & Anchor Bolt Hexagon Nuts
M30 For Anchor Bolts
M27
13. WASHERS
WASHER DIAMETER (mm) USAGE SPECIFICATION
M16
For Anchor Bolts DIN 125 Type A
M20
Flat Mild Electro-
M24 For Anchor Bolts and Cable Bracing Galvanized
M30 For Anchor Bolts
M12
M16
For High Strength Bolt of ASTM F436 Type 1
M20
Main Connections Round Hard
M24
M27
ASTM A48M Class 275B
M24 Bracing System HDG (Hill Side Washer)