PRODUCT IMPROVEMENT PROGRAM FOR INSPECTING THE CARRIER ASSEMBLY ON
THE POWERTRAIN GEAR PUMP ON CERTAIN D9T AND D10T TRACK-TYPE TRACTORS
Nmero de medio -REBE3508-00 Fecha de publicacin -2008/08/04 Fecha de actualizacin -2008/08/04
CONFIDENTIAL
REBE3508-00
Ver imagen
04Aug2008
U-402
A-327
D-330
O-366
https://sis.cat.com/sisweb/sisweb/techdoc/content.jsp?calledpage=/sisweb/sisweb/med... 11/08/2008
Service Information System Pgina 2 de 9
28Feb2009 31Aug2009
PROBLEM
The powertrain gear pump has a carrier assembly which needs to be
inspected on certain D9T and D10T Track-Type Tractors that have
under 500 hours on the Service Meter Reading (SMR). The existing
powertrain gear pump can fail due to the mis-location of bearing
drain holes on the carrier assembly.
AFFECTED PRODUCT
Model Identification Number
*******Group 1*******
D10T RJG01400-01510
*******Group 2*******
D9T RJS00990-01060
PARTS NEEDED
*******Group 1*******
*******Group 2*******
https://sis.cat.com/sisweb/sisweb/techdoc/content.jsp?calledpage=/sisweb/sisweb/med... 11/08/2008
Service Information System Pgina 3 de 9
ACTION REQUIRED
Refer to the attached Rework Procedure for the inspection
procedure.
OWNER NOTIFICATION
U.S. and Canadian owners will receive the attached Owner
Notification.
*******Group 1*******
100% 100% 0% 0% 0% 0%
0.5 hrs is allowed to check the Service Meter Reading for machine
hours. An additional 1 hr is allowed to check the carrier
assembly. If the carrier assembly is found to be bad, an
additional 8 hrs will be allowed for replacing the pump. If the
pump has already failed and system clean up is necessary, an
additional 40 hrs will be allowed for system clean out per
REHS4331.
*******Group 2*******
100% 100% 0% 0% 0% 0%
0.5 hrs is allowed to check the Service Meter Reading for machine
hours. An additional 1 hr is allowed to check the carrier
assembly. If the carrier assembly is found to be bad, an
additional 8 hrs will be allowed for replacing the pump. If the
pump has already failed and system clean up is necessary, an
https://sis.cat.com/sisweb/sisweb/techdoc/content.jsp?calledpage=/sisweb/sisweb/med... 11/08/2008
Service Information System Pgina 4 de 9
PARTS DISPOSITION
If a pump has failed, the pump needs to be returned to Caterpillar
Hydraulics and Hydraulic Systems Global Headquarters at the
following address:
XYZ Corporation
3240 Arrow Drive
Anywhere, YZ 99999
Please refer the dealer to their Service Letter dated 04Aug2008 when
scheduling this service.
We regret the inconvenience this may cause you, but urge you to have
this service performed as soon as possible to prevent unscheduled
https://sis.cat.com/sisweb/sisweb/techdoc/content.jsp?calledpage=/sisweb/sisweb/med... 11/08/2008
Service Information System Pgina 5 de 9
downtime.
Caterpillar Inc.
Identification #(s)
Rework Procedure
1. Inspect the service meter. If the machine has over 500 hours on
the service meter, no further action is required. If the machine has
less than 500 hours on the service meter, proceed to Step 2.
3. Locate the powertrain gear pump (272-6588 for D9T, 201-8390 for
D10T). Reference manual RENR7533 for D9T and RENR7547 for D10T.
Ver imagen
https://sis.cat.com/sisweb/sisweb/techdoc/content.jsp?calledpage=/sisweb/sisweb/med... 11/08/2008
Service Information System Pgina 6 de 9
Image1.4.1
Ver imagen
https://sis.cat.com/sisweb/sisweb/techdoc/content.jsp?calledpage=/sisweb/sisweb/med... 11/08/2008
Service Information System Pgina 7 de 9
Image1.4.2
Ver imagen
Image1.4.3
Ver imagen
https://sis.cat.com/sisweb/sisweb/techdoc/content.jsp?calledpage=/sisweb/sisweb/med... 11/08/2008
Service Information System Pgina 8 de 9
Image1.4.4
Ver imagen
Image1.4.5
Image 1.4.1 shows the incorrect locations of the drain holes (off
center of the carrier assembly).
Image 1.4.2 shows the correct locations of the drain holes (on
center of the carrier assembly), with correct dimensions.
Image 1.4.3 shows the additional view of pump with correct location
of the drain holes.
https://sis.cat.com/sisweb/sisweb/techdoc/content.jsp?calledpage=/sisweb/sisweb/med... 11/08/2008
Service Information System Pgina 9 de 9
Image 1.4.4 shows the additional view of pump with correct location
of the drain holes.
Image 1.4.5 shows the additional view of pump with correct location
of the drain holes.